Abstract
An indirect fluorescent-antibody (FA) procedure employing soluble antigen fixed onto an artificial matrix was developed, and a mechanical means for reading of test results was devised. The method employs two small cellulose acetate paper discs for each test. One disc contains soluble antigen diluted in 1% bovine serum albumin (BSA); the other contains only 1% BSA and serves as a control. After testing by the indirect FA procedure, the results of the tests are read on a fluorometer fitted with a paper chromatogram door. The instrument is set at zero with the control disc as a blank, and the specific fluorescence of the antigen disc is determined. Findings obtained with homologous and heterologous antisera indicated that the method yields excellent results. The soluble antigen fluorescent-antibody technique has definite advantages over the conventional indirect FA procedures. (i) The investigator may objectively select the antigen to be employed. (ii) It is possible to obtain objective mechanical reading of test results rather than the highly subjective readings required by conventional methods. (iii) The system compensates for any nonspecific fluorescence contributed either by the serum (e.g., drugs) or by free fluorescein in the conjugated antiserum.
Full text
PDF






Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- ANDERSON R. I., NAIMARK D. H. Serologic diagnosis of Schistosoma mansoni infections. II. Sensitivity of intradermal and serologic tests on individuals with an unequivocal diagnosis of schistosomiasis. Am J Trop Med Hyg. 1960 Nov;9:600–603. doi: 10.4269/ajtmh.1960.9.600. [DOI] [PubMed] [Google Scholar]
- ANDERSON R. I. Relationship of antibody nitrogen to titer obtained in the cercarial antigen slide flocculation test for schistosomiasis. Exp Parasitol. 1962 Dec;12:434–440. doi: 10.1016/0014-4894(62)90079-6. [DOI] [PubMed] [Google Scholar]
- CHAFFEE E. F., BAUMAN P. M., SHAPILO J. J. Diagnosis of schistosomiasis by complement-fixation. Am J Trop Med Hyg. 1954 Sep;3(5):905–913. doi: 10.4269/ajtmh.1954.3.905. [DOI] [PubMed] [Google Scholar]
- CHAFFEE E. F., NIEVES E. E. Serodiagnosis of schistosomiasis: specificity of the complement-fixation test in other helminthic infections. Am J Trop Med Hyg. 1957 Jul;6(4):727–730. doi: 10.4269/ajtmh.1957.6.727. [DOI] [PubMed] [Google Scholar]
- CRAWFORD H. J., WOOD R. M., LESSOF M. H. Detection of antibodies by fluorescent-spot technique. Lancet. 1959 Dec 26;2(7113):1173–1174. doi: 10.1016/s0140-6736(59)91743-x. [DOI] [PubMed] [Google Scholar]
- FRIOU G. Fluorescent spot test for anti-nuclear antibodies. Arthritis Rheum. 1962 Aug;5:407–410. doi: 10.1002/art.1780050409. [DOI] [PubMed] [Google Scholar]
- GOLDMAN M. Antigenic analysis of Entamoeba histolytica by means of fluorescent antibody. I. Instrumentation for microfluorimetry of stained amebae. Exp Parasitol. 1960 Feb;9:25–36. doi: 10.1016/0014-4894(60)90006-0. [DOI] [PubMed] [Google Scholar]
- JACHOWSKI L. A., ANDERSON R. I. Evaluation of some laboratory procedures in diagnosing infections with Schistosoma mansoni. Bull World Health Organ. 1961;25:675–693. [PMC free article] [PubMed] [Google Scholar]
- KENT J. F., FIFE E. H., Jr Precise standardization of reagents for complement fixation. Am J Trop Med Hyg. 1963 Jan;12:103–116. doi: 10.4269/ajtmh.1963.12.103. [DOI] [PubMed] [Google Scholar]
- PARONETTO F. The fluorescent antibody technique applied to titration and identification of antigens in solutions or antisera. Proc Soc Exp Biol Med. 1963 Jun;113:394–397. doi: 10.3181/00379727-113-28375. [DOI] [PubMed] [Google Scholar]