Abstract
Accurate measures of the severity of respiratory disease are important, both clinically and epidemiologically. The apparent prognostic value of static respiratory system compliance (Crs) on the first day and mean appropriate fractional inspired oxygen (FIO2) in the first 12 hours of life were compared in 48 infants who received mechanical ventilation in a regional neonatal unit. Their median (range) gestation was 30 (25-41) weeks and they were representative of all 140 newborn infants born to residents of a geographically defined area who received mechanical ventilation over a 30 month period. Using the best cut off value (< or = 0.6 ml/cm H2O/m corrected for body length), static Crs predicted hospital death with 98% accuracy, 80% sensitivity, and 100% specificity. Using the best cut off value (> 0.60), mean FIO2 in the first 12 hours predicted hospital death with 81% accuracy, 80% sensitivity, and 81% specificity. Static Crs appeared to be a more accurate measure of respiratory function and disease severity than mean FIO2, perhaps because static Crs is less dependent on ventilator management than routine indices based on blood gases. Static Crs now merits wider evaluation, both as an aid to routine clinical management and as a prognostic index in comparative studies.
Full text
PDF




Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Avery M. E., Tooley W. H., Keller J. B., Hurd S. S., Bryan M. H., Cotton R. B., Epstein M. F., Fitzhardinge P. M., Hansen C. B., Hansen T. N. Is chronic lung disease in low birth weight infants preventable? A survey of eight centers. Pediatrics. 1987 Jan;79(1):26–30. [PubMed] [Google Scholar]
- Balakrishnan G., Aitchison T., Hallworth D., Morton N. S. Prospective evaluation of the Paediatric Risk of Mortality (PRISM) score. Arch Dis Child. 1992 Feb;67(2):196–200. doi: 10.1136/adc.67.2.196. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Crowley P., Chalmers I., Keirse M. J. The effects of corticosteroid administration before preterm delivery: an overview of the evidence from controlled trials. Br J Obstet Gynaecol. 1990 Jan;97(1):11–25. doi: 10.1111/j.1471-0528.1990.tb01711.x. [DOI] [PubMed] [Google Scholar]
- Hamilton P. P., Onayemi A., Smyth J. A., Gillan J. E., Cutz E., Froese A. B., Bryan A. C. Comparison of conventional and high-frequency ventilation: oxygenation and lung pathology. J Appl Physiol Respir Environ Exerc Physiol. 1983 Jul;55(1 Pt 1):131–138. doi: 10.1152/jappl.1983.55.1.131. [DOI] [PubMed] [Google Scholar]
- Haouzi P., Marchal F., Crance J. P., Monin P., Vert P. Respiratory mechanics in spontaneously breathing term and preterm neonates. Biol Neonate. 1991;60(6):350–360. doi: 10.1159/000243432. [DOI] [PubMed] [Google Scholar]
- Horbar J. D., Onstad L., Wright E. Predicting mortality risk for infants weighing 501 to 1500 grams at birth: a National Institutes of Health Neonatal Research Network report. Crit Care Med. 1993 Jan;21(1):12–18. doi: 10.1097/00003246-199301000-00008. [DOI] [PubMed] [Google Scholar]
- Kelly E., Bryan H., Possmayer F., Frndova H., Bryan C. Compliance of the respiratory system in newborn infants pre- and postsurfactant replacement therapy. Pediatr Pulmonol. 1993 Apr;15(4):225–230. doi: 10.1002/ppul.1950150408. [DOI] [PubMed] [Google Scholar]
- Kirpalani H., Schmidt B., Gaston S., Santos R., Wilkie R. Birthweight, early passive respiratory system mechanics, and ventilator requirements as predictors of outcome in premature infants with respiratory failure. Pediatr Pulmonol. 1991;10(3):195–198. doi: 10.1002/ppul.1950100311. [DOI] [PubMed] [Google Scholar]
- Knaus W. A., Draper E. A., Wagner D. P., Zimmerman J. E. APACHE II: a severity of disease classification system. Crit Care Med. 1985 Oct;13(10):818–829. [PubMed] [Google Scholar]
- Lesouef P. N., England S. J., Bryan A. C. Passive respiratory mechanics in newborns and children. Am Rev Respir Dis. 1984 Apr;129(4):552–556. [PubMed] [Google Scholar]
- Migdal M., Dreizzen E., Praud J. P., Vial M., Dehan M., Chambille B., Gaultier C. Compliance of the total respiratory system in healthy preterm and full-term newborns. Pediatr Pulmonol. 1987 Jul-Aug;3(4):214–218. doi: 10.1002/ppul.1950030404. [DOI] [PubMed] [Google Scholar]
- Olinsky A., Bryan A. C., Bryan M. H. A simple method of measuring total respiratory system compliance in newborn infants. S Afr Med J. 1976 Jan 31;50(5):128–130. [PubMed] [Google Scholar]
- Patterson C. C., Halliday H. L. Prediction of outcome shortly after delivery for the very low birthweight (less than or equal to 1500 g) infant. Paediatr Perinat Epidemiol. 1988 Jul;2(3):221–228. doi: 10.1111/j.1365-3016.1988.tb00211.x. [DOI] [PubMed] [Google Scholar]
- Pollack M. M., Ruttimann U. E., Getson P. R. Accurate prediction of the outcome of pediatric intensive care. A new quantitative method. N Engl J Med. 1987 Jan 15;316(3):134–139. doi: 10.1056/NEJM198701153160304. [DOI] [PubMed] [Google Scholar]
- Simbruner G., Coradello H., Lubec G., Pollak A., Salzer H. Respiratory compliance of newborns after birth and its prognostic value for the course and outcome of respiratory disease. Respiration. 1982;43(6):414–423. doi: 10.1159/000194512. [DOI] [PubMed] [Google Scholar]
- Simbruner G. Inadvertent positive end-expiratory pressure in mechanically ventilated newborn infants: detection and effect on lung mechanics and gas exchange. J Pediatr. 1986 Apr;108(4):589–595. doi: 10.1016/s0022-3476(86)80845-9. [DOI] [PubMed] [Google Scholar]
- Stenson B. J., Glover R. M., Parry G. J., Wilkie R. A., Laing I. A., Tarnow-Mordi W. O. Static respiratory compliance in the newborn. III: Early changes after exogenous surfactant treatment. Arch Dis Child Fetal Neonatal Ed. 1994 Jan;70(1):F19–F24. doi: 10.1136/fn.70.1.f19. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tarnow-Mordi W., Ogston S., Wilkinson A. R., Reid E., Gregory J., Saeed M., Wilkie R. Predicting death from initial disease severity in very low birthweight infants: a method for comparing the performance of neonatal units. BMJ. 1990 Jun 23;300(6740):1611–1614. doi: 10.1136/bmj.300.6740.1611. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Thomson A. H., Beardsmore C. S., Silverman M. The total compliance of the respiratory system during the first year of life. Bull Eur Physiopathol Respir. 1985 Sep-Oct;21(5):411–416. [PubMed] [Google Scholar]
- Wilkie R. A., Bryan M. H., Tarnow-Mordi W. O. Static respiratory compliance in the newborn. II: Its potential for improving the selection of infants for early surfactant treatment. Arch Dis Child Fetal Neonatal Ed. 1994 Jan;70(1):F16–F18. doi: 10.1136/fn.70.1.f16. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Yeh T. F., Torre J. A., Rastogi A., Anyebuno M. A., Pildes R. S. Early postnatal dexamethasone therapy in premature infants with severe respiratory distress syndrome: a double-blind, controlled study. J Pediatr. 1990 Aug;117(2 Pt 1):273–282. doi: 10.1016/s0022-3476(05)80547-5. [DOI] [PubMed] [Google Scholar]
