ABSTRACT
Background:
A systematic literature review was performed to understand the prevalence, advantages, and disadvantages of blood collection using different approaches (direct venipuncture or vascular access devices), and interventions used to mitigate the disadvantages.
Methods:
The review included a broad range of study designs and outcomes. Database searches (Embase, MEDLINE, Cochrane library, and Centre for Reviews and Dissemination) were conducted in March 2021 and supplemented by hand searching.
Results:
One hundred forty-one publications were included. The data indicate that blood sampling from vascular access devices is common in emergency departments, trauma centers, and intensive care units. Studies showed that hemolysis and sample contamination place a considerable economic burden on hospitals. Significant cost savings could be made through enforcing strict aseptic technique, or using the initial specimen diversion technique.
Conclusions:
Hemolysis and sample contamination are far from inevitable in vascular access device-collected or venipuncture samples; both can be reduced through adherence to strict blood sampling protocols and utilization of the initial specimen diversion technique. Needle-free blood collection devices offer further hope for reducing hemolysis. No publication focused on the difficult venous access population; insertion success rates are likely to be lower (and the benefits of vascular access devices higher) in these patients.
Introduction
Blood testing is essential for diagnosis, treatment, and monitoring. Almost 500 million inpatient blood collections are performed in United States (US) hospitals each year,1 informing 60–70% of clinical decisions.2
Although blood collection via direct venipuncture is considered standard of care,3 there are several potential advantages of collecting blood from indwelling vascular access devices (VADs), which can affect the quality of care. These include reducing the stress and discomfort associated with needle punctures,4,5 and minimizing the number of venipunctures for patients requiring repeated blood sampling. This is particularly important in patients with difficult venous access (DIVA),6 who represent more than one-third of all venipuncture patients7 and often require several attempts to successfully collect blood.8-10
Recent innovations include initial specimen diversion devices (ISDDs) that automatically divert and sequester the initial 1–2 ml of blood from blood culture samples and are intended to reduce contamination rates.11 Others include needle-free blood collection systems, which are intended to reduce hemolysis rates and increase blood collection success rates from peripheral intravenous catheters (PIVCs) in place for several days.12
A systematic literature review (SLR) was performed to gather contemporary evidence on blood collection and compare clinical, economic, and humanistic outcomes across different approaches. The objective was to gain a better understanding of the prevalence, advantages, and disadvantages of blood collection using different approaches, and any interventions/innovations that can been used to mitigate the disadvantages.
Methods
Electronic database searches were conducted on 5th and 8th March 2021 and were date-limited from 2010 to the present day, to only capture contemporary data. The review was not registered, and a protocol is available upon request. Embase, MEDLINE, Cochrane Library databases, and Centre for Reviews and Dissemination databases were searched via the Ovid platform. The full electronic search strategy is presented in Supplemental Digital Content 1 (see Tables S1–S3, http://links.lww.com/JHQ/A195). Hand-searching was also performed by screening bibliographic reference lists of included studies and relevant SLRs/meta-analyses. The population of interest was patients requiring blood collection for diagnostic, prognostic, or treatment monitoring purposes, regardless of disease/indication. Relevant interventions included blood collection by a range of approaches, such as direct venipuncture, PIVCs, midline catheters, and central lines (encompassing peripherally inserted central catheters [PICCs], centrally inserted central catheters [CICCs], and implanted ports). The focus of this SLR was venous blood collection, so studies on arterial catheters were not eligible for inclusion. The full population, intervention, comparator(s), outcomes, and study design (PICOS) elements used to assess study eligibility are presented in Supplemental Digital Content 1 (see Table S4, http://links.lww.com/JHQ/A195).
Two independent reviewers screened citations by title/abstract, with any conflicts regarding eligibility resolved by discussion. Full-texts were also evaluated by two independent reviewers, with any disputes regarding eligibility resolved by dialogue. Arbitration was provided by a third, more senior reviewer if required.
Results
Seven thousand three hundred thirty-five publications were identified through electronic database searches. Overall, 141 publications were included in the final review, comprising 132 publications identified via database searches, and nine publications identified via hand-searching. The flow of publications through the SLR is shown in Figure 1.
Figure 1.
PRISMA diagram. PRISMA, Preferred Reporting Items for Systematic Reviews and Meta-Analyses.
The included publications reported on studies performed across geographical locations spanning six continents, and a diverse range of study designs, including cross-sectional surveys and questionnaires, randomized and nonrandomized trials, and prospective and retrospective observational studies.
Proportion of Blood Samples Collected by Device Type
Sixteen publications reported the proportion of total blood samples in a particular hospital or ward/department using specific device types (Table 1). As anticipated, blood sampling through VADs was most common in emergency departments (EDs), trauma centers, intensive care units (ICUs), and hematology-oncology units. A survey spanning multiple sites across the US, Puerto Rico, and Canada determined that in ICU patients with existing central lines, blood culture samples were drawn through these existing lines in 52% of adult and 96% of pediatric practices. For hematology–oncology and bone marrow transplant patients, the respective figures were 64% and 98%.29
Table 1.
Proportion of Blood Samples Collected by Device Type in the Hospital Setting
| Reason for collecting blood | Setting | Author, year | Country | Proportion of blood samples collected by device type | |||
| Direct VP | PIVC | Central linea | Otherb | ||||
| Blood culture | ED | Self et al, 201213 | US | — | 23.1% | — | 76.9% |
| ICU | Alahmadi et al, 201514 | Northern Ireland | 41.0% | — | 33.3% | 25.7% | |
| ICU + wider hospital | Boyce et al, 2013c,15 | US | 89.1% | — | 10.9% | — | |
| NICU | McLaughlin et al, 201316 | Australia | 5.0% | 62.2% | — | 32.8% | |
| PICU | Woods-Hill et al, 2017c,17 | US | 26.9% | — | 73.1% | — | |
| Routine testing | Clinical laboratory of level 1 pediatric trauma center | Bush et al, 201018 | US | 30% | 70% | — | — |
| ED | Barnard et al, 201619 | UK | 30.5% | 69.5% | — | — | |
| Berg et al, 201120 | UK | 20% | 80% | — | — | ||
| Dietrich et al, 201421 | US | 36.9% | 63.1% | — | — | ||
| Guihard et al, 201822 | France | — | 80% | — | 20% | ||
| Lippi et al, 201423 | Italy | 22% | 78% | — | — | ||
| Ramakers et al, 201824 | The Netherlands | — | 80% | — | 20% | ||
| ICU | Bodley et al, 202125 | Canada | — | — | 17.4% | 82.6% | |
| Kuriakose et al, 2020c,26 | US | 10% | — | 70% | 20% | ||
| NICU | Tolan et al, 201627 | US | 29% | 33% | — | 38% | |
| PICU | Valentine et al, 201228 | US | 4% | 6% | 33% | 57% | |
CICC, centrally inserted central catheter; ED, emergency department; ICU, intensive care unit; IV, intravenous; NICU, neonatal intensive care unit; PICC, peripherally inserted central catheter; PICU, pediatric intensive care unit; PIVC, peripheral intravenous catheter; UK, United Kingdom; US, United States; VP, venipuncture.
PICCs, ports and CICCs.
Including arterial and dialysis lines.
Proportions reported are preintervention. After interventions, the proportions were: direct VP 99.6%, central line 0.4% (Boyce), direct VP 60.5%, central line 39.5% (Woods-Hill), and CICC 3% (Kuriakose).
The studies in Table 1 are categorized based on the purpose of blood collection (blood culture or routine), because many publications reported that healthcare professionals (HCPs) in their institution were explicitly advised not to collect blood culture samples from VADs to minimize the risk of bloodstream infection and sample contamination. A 2018 survey of over 80 hospitals in the US revealed that 90% of hospitals advise staff to collect culture samples via direct venipuncture rather than from central VADs wherever possible.30
Placement and Blood Collection Success by Device Type
Overall, 28 publications reported placement and blood collection success outcomes such as first attempt insertion success rate, number of attempts required to access the vein, blood collection success after venous access, or an overall success rate encompassing insertion and blood collection success.
Summary statistics were challenging to derive because of the variation in measuring and reporting. Nevertheless, the accumulated data indicate that in most patients, even if multiple attempts are sometimes required, blood collection via direct venipuncture is ultimately successful in obtaining a sample.
Importantly, it is not always possible to obtain complete blood samples from indwelling catheters. Across three pediatric studies, overall success rates for obtaining useable blood samples from existing PIVCs were 91.3%, 76%, and 85.1%.31-33 In addition, the ability to obtain a specimen from a PIVC may decrease as the catheter ages. In one of the three studies, the rate of successful PIVC blood collection decreased from 85% in PIVCs aged <24 hours to just 63% in PIVCs aged >24 hours (p = .010).33 The size of the PIVC was not significantly associated with the ability to obtain a specimen; however, results revealed a trend indicating that larger gauge PIVCs were more successful in providing a complete specimen, whereas the smallest gauge PIVC was less successful.33
Only one study reported on the ease of blood sampling from PIVCs using the needle-free PIVO device, which is designed for PIVC blood collection. The blood collection success rate was 81% across 126 blood collections in 62 hospitalized patients performed over 4 days.34
Hemolysis of Blood Samples by Device Type
Of the 36 publications that reported hemolysis rates, 18 compared rates between two devices, and 18 reported rates for a single device category. Hemolysis rates were numerically higher in catheter-collected samples in 14/17 publications comparing direct venipuncture and PIVC blood collection (Table 2). Of these, the difference was statistically significant in all five publications that presented a p-value.
Table 2.
Studies Comparing Hemolysis Rates Between Blood Samples Collected by Direct Venipuncture and PIVCs
| Author, year | Country | Setting | Hemolysis rate numerically higher with PIVC or direct VP? | Hemolysis rate in PIVC samples | Hemolysis rate in direct VP samples | p |
| Barnaby et al, 201635 | US | ED | PIVC | 6,225/55,082 (11.3%) | 1,468/33,881 (4.3%) | NR |
| Barnard, 201619 | UK | ED | PIVC | 14.3% | 2.7% | p < .001 |
| Berg et al, 201120 | UK | Emergency medicine, hospital inpatients | PIVC | 10/40 (25%) | 2/10 (20%) | NR |
| Berger-Achituv et al, 201031 | Israel | Pediatric surgery and pediatrics | Direct VP | 0/34 | 1/34 | NR |
| Bush et al, 201018 | US | Clinical laboratory of level 1 pediatric trauma center | PIVC | 25/155 (16%) | 4/66 (6%) | p = .04 |
| Giavarina et al, 201036 | Italy | ED | PIVC | BD Insyte Autoguard: 22.9% B Braun Vasofix Safety: 18.2% Terumo Surflo-w: 23% Neo Delta Ven T: 16.1% |
3% | NR |
| Hambleton et al, 201437 | Spain | ED | NR | “No significant differences between the percentage of hemolysis in samples extracted from the PIVC and those from venipuncture” | p = .4 | |
| Heiligers-Duckers et al, 201338 | The Netherlands | ED Reference group: Internal medicine ward and outpatient clinic |
PIVC | Syringe tube samples: 16% Vacuum tube samples: 24% |
3% | p ≤ .02 |
| Lippi et al, 201423 | Italy | Large urban ED | PIVC | 29% | 1% | NR |
| Mattila et al, 201739 | Finland | Ambulance (samples takenbefore hospital admission) and ER (samples taken upon hospital admission) | PIVC | EDTA plasma samples: 9.3% Serum samples: 6.5% |
EDTA plasma samples: 1.6% Serum plasma: 0.7% |
NR |
| Munnix et al, 201140 | The Netherlands | ED and an internal medicine outpatient clinic | PIVC | Retrospective review: 574/8,710 Prospective study: 16/100 (16%) |
Retrospective review: 105/9,754 Prospective study: 0/50 (0%) |
NR |
| Ortells-Abuye et al, 201441 | Spain | Inpatient ward or emergency services short stay unit | PIVC | 3.7% | 0% | NR |
| Phelan et al, 201842 | US | ED | PIVC | Hemolyzed: 8.2% Gross hemolysis: 2.0% Hemolyzed or gross hemolysis: 10.2% |
Hemolyzed: 4.2% Gross hemolysis: 1.1% Hemolyzed or gross hemolysis: 5.4% |
p < .001 p = .12 p < .001 |
| Straszewski et al, 201143 | US | ED | PIVC | Samples collected by PIVC or direct VP: 23% | Samples collected by direct VP only: 6.6% | NR |
| Tolan et al, 201627 | US | NICU | Direct VP | 13% | 15% | NR |
| Twibell et al, 201944 | US | Pediatric unit | PIVC | 15% | 4% | p = .002 |
| Wollowitz et al, 201345 | US | ED | PIVC | 14.6% | 2.7% | NR |
BD, Becton, Dickinson and Company; ED, emergency department; EDTA, ethylenediaminetetraacetic acid; ER, emergency room; NICU, neonatal intensive care unit; NR, not reported; PIVC, peripheral intravenous catheter; UK, United Kingdom; US, United States; VP, venipuncture.
Although hemolysis rates were generally higher in PIVC than direct venipuncture blood samples, the accumulated data suggest that the risk of hemolysis is lowered when specific sampling procedures are followed, such as collecting blood from the antecubital fossa,19,42,45 using larger gauge needles,42,45 ensuring not to underfill collection tubes,45 keeping tourniquet time to under a minute,42,45 and discarding the initial portion of blood.40
Two studies reported on the use of the PIVO device to collect blood samples from patients with PIVCs.12,34 The first reported significantly lower hemolysis rates in blood samples collected from PIVCs using the PIVO device (1.8%) relative to those collected more conventionally, by direct venipuncture or from central lines (3.3%).12 The other reported a hemolysis rate of 0% in an intervention group that underwent daily blood sampling from a PIVC using the PIVO device.34
Sample Contamination/False Positives in Blood Cultures by Device Type
Thirty-one publications reported sample contamination rates. Of these, 10 compared two devices, whereas the other 21 reported rates for a single device, or data pooled across two devices.
In studies comparing direct venipuncture and VAD-collected blood samples, contamination rates were numerically higher among VAD-collected samples in 7/10 publications, but lower in 2/10 publications (Table 3). In both latter studies, blood was collected from PIVCs at insertion rather than over dwell, and samples were collected following strict sterile protocols.16,47
Table 3.
Studies Comparing Contamination rates Between Blood Samples Collected by Direct Venipuncture and VADs
| Author, year | Country | Setting | Comparison | Contamination rate numerically higher with VAD or direct VP? | Contamination rate in VAD-collected samples | Contamination rate in direct VP samples | p |
| Alahmadi et al, 201514 | Northern Ireland | ICU | Direct VP versus CICC | VAD | 9.5% | 4.8% | NR |
| Boyce et al, 201315 | US | ICU and wider hospital | Direct VP versus unspecified central lines | VADa | All wards except ED and ICU in 2010a: 44/921 (4.8%) ICUs only in 2010a: 21/422 (5%) |
All wards except ED and ICU in 2010a: 40/4,353 (0.9%) ICUs only in 2010a: 7/869 (0.8%) |
NR |
| Jones et al, 201746 | US | NR | Direct VP versus CICC | Neither | 1.4% | 1.4% | NR |
| Kelly et al, 201347 | Australia | ED | Direct VP versus PIVC | Direct VP | 3.2% | 3.6% | p = .52 |
| McLaughlin et al, 201316 | Australia | NICU | Direct VP versus PIVC | Direct VP | 2.2% | 13.7% | NR |
| Ramirez et al, 201548 | Spain | ICU | Direct VP versus unspecified IV catheters | VAD | 17% | 7% | p = .028 |
| Santos et al, 201849 | US | NR | Direct VP versus unspecified central lines | VAD | Contaminated samples/1,000 samples with samples collected by central lines or direct VP: 3.8 | Contaminated samples/1,000 samples with blood collected almost exclusively by direct VP: 3.4 | p = .569 |
| Self et al, 201213 | US | ED | Direct VP versus PIVC | VAD | 6.53% | 3.56% | NR |
| Stohl et al, 201150 | Israel | ICU | Direct VP versus CICC | VAD | 8% | 4% | p < .001 |
| Weddle et al, 201151 | US | ED | Direct VP versus PIVC | VAD | Samples collected by PIVC or direct VP: 6.7% | Samples collected by direct VP only: 2.3% | p = .001 |
CICC, centrally inserted central catheter; ED, emergency department; ICU, intensive care unit; IV, intravenous; NICU, neonatal intensive care unit; NR, not reported; PIVC, peripherally inserted central catheter; US, United States; VAD, vascular access device; VP, venipuncture.
Contamination rate was higher in VAD-collected samples than direct venipuncture samples at the beginning of the study in 2010, but this trend was reversed by the end of the study after an intervention to reduce contamination rates.
Interventions to reduce contamination rates in VAD collections have been shown to be effective; in a US hospital, training in aseptic technique contributed to a reduction in contamination rates from 4.8% to 0% (p = .005) for central lines.15 Another study reported a significant reduction in contamination rates among PIVC-collected samples, from 3.9% to 1.6% (p < .0001), following enforcement of a strict sterile technique for PIVC insertion and blood collection.52 This implies that sample contamination is not inevitable during VAD blood sampling, and if applied strictly, aseptic protocols can virtually eradicate contamination risk.
There is also room for improvement in blood culture contamination rates for direct venipuncture. Kai et al.53 demonstrated a drop in contamination rates from 6.3% to 1.1% (p < .001) in a Japanese ED after implementation of a six-element intervention “bundle” that included alcohol wiping, improved hand hygiene, and the use of sterile gloves during venipuncture.
Impact of the Initial Specimen Diversion Technique on Sample Quality
Multiple publications evaluated the impact of the initial specimen diversion technique (ISDT) on sample contamination or hemolysis rates. In the earliest of these studies, Patton et al. discovered that discarding the first 1 ml of blood sample collected by direct venipuncture significantly reduced false-positive blood cultures.54 The authors concluded that venipuncture needles can soil blood culture specimens with unsterilized skin fragments, and thus the ISDT is effective in reducing contamination. Two subsequent studies involving direct venipuncture sampling reported similar results; blood culture contamination rates dropped from 3.4% to 2.4% after the ISDT was adopted at a Canadian institution,55 whereas a randomized trial in an Israeli medical center documented a 1.7% contamination rate in an ISDT group relative to 5% in a control group (p = .015).56
The SLR identified two publications that testify to the effectiveness of bespoke ISDDs. In a US ED and trauma center, contamination rate was only 0.22% in cultures prepared with an ISDD, compared with 1.78% without one (p = .001).57 In an Israeli hospital, an ISDD was used with an integrated needle or by attaching it to a newly-placed intravenous (IV) catheter; contamination rate was 1.0% with the ISDD and 5.2% without it (p = .008).11
Other Sample Quality Issues
Seven publications documented the number of blood samples rendered unsuitable for analysis because of clotting, coagulation, or underfilled tubes, although only two enabled direct comparison between different device types (Table 4).
Table 4.
Studies Documenting Sample Quality Issues
| Author, year | Country | Setting | Blood collection method | Proportion of samples unsuitable for analysis and reasons |
| Lancé et al, 201358 | The Netherlands | Operating theater | Direct VP | 9.1% because of coagulation |
| Venous line | 0% | |||
| Large bore central venous line | 0% | |||
| Ortells-Abuye et al, 201441 | Spain | Inpatient ward or emergency services short stay unit | Direct VP | 0.7% because of clotting |
| PIVC | 0.4% because of clotting | |||
| Atay et al, 201459 | Turkey | Laboratory serving inpatients, outpatients and ED | Direct VP | 0.65%; of these, 24% rejected because of clotting and 34% because of insufficient sample volume |
| Bhushan, and Sen, 201760 | India | Coagulation laboratory | Direct VP | 0.11% because of clotting 0.39% because of underfilled vacutainer tubes |
| Goswami et al, 201061 | India | Tertiary hospital | Direct VP | 1.4%; of these, 7.5% rejected because of insufficient sample volume |
| Braniff et al, 201432 | US | Pediatric unit or pediatric ICU | PIVC | 0.67% because of clotting 0% because of insufficient sample volume |
| Berger-Achituv et al, 201031 | Israel | Pediatric surgery and pediatrics | PIVC | 4.26% because of coagulation 4.26% because of insufficient sample volume |
ED, emergency department; ICU, intensive care unit; PIVC, peripheral intravenous catheter; US, United States; VP, venipuncture.
Anxiety, Fear, and Stress by Device Type
Eleven studies presented self-reported measures of patient anxiety, fear, or stress aroused by blood collection via direct venipuncture, and one via IV catheters, but none compared these across device types.
Healthcare Costs, Resource Utilization, and Economic Burdens by Device Type
Thirty-six publications reported data regarding healthcare resource utilization, and 13 publications on specific costs or economic burdens. Of note, two studies showed blood culture contamination to be associated with a longer length of stay and increased costs56,62; in another study, each contaminated blood culture resulted in an additional $2,800 of hospital charges.52 In all three studies, the additional spending was principally attributable to patients' increased length of stay. In an Italian ED, the economic burden attributable to sample rejection because of hemolysis was €19,535 ($22,551) in 2012 (€17,484 [$20,183] for materials and €2,051 [$2,368] for personnel), accounting for 22.8% of the department's annual expenditure on blood sample collection.Currency converted from Euros to United States Dollars on 14th October, 2021 using exchange rates from Google Finance (https://www.google.com/intl/en/googlefinance/disclaimer/).23
Logically, interventions that reduce blood culture contamination rates should also decrease healthcare resource use and hospital spending. In the study by Hall et al.,52 enforcement of a strict sterile technique for PIVC insertion and blood draw decreased blood culture contamination rates, saving the hospital approximately $250,000 annually. Another publication presented a cost-benefit analysis evaluating use of the SteriPath ISDD for ED blood culture collection, compared with direct venipuncture.62 Use of the ISDD was associated with cost savings of $272 (3%) per blood culture in overall hospital costs, and $28 (5.4%) in direct-only costs. The main drivers of these cost savings were decreased contamination rates and reduced duration of antibiotic administration. In a Canadian institution, adoption of a manual ISDT was forecasted to yield savings of between $143,000 and $1,246,960 per year.55
Time Saved or Lost during the Blood Collection Pipeline
Nineteen publications reported data on the time spent waiting for an HCP to arrive to collect blood, the duration of the blood collection procedure, or the waiting time for recollection in the event of sample rejection. The only study to directly compare the duration of sampling between relevant devices revealed that blood collection by direct venipuncture took longer than from an existing PIVC (175.8 ± 229.6 vs. 104.5 ± 53.4 seconds; p = .053).31
Risk of Anemia
Another concern expressed in multiple studies was that repeated blood sampling in hospitalized patients can lead to anemia, and greater efforts should be made to minimize blood wastage during blood collection to safeguard patients' wellbeing.25,28 A study performed in a Canadian ICU established that on average, 5.5 ml of blood is wasted during each draw from a central venous line, compared with 6.3 ml from a PICC.25 In a US-based pediatric ICU, the mean volume of blood drawn in excess of laboratory requirements was 1.9 ml for centrally inserted central catheters, but only 1.2 ml for PIVCs, and 0.8 ml for direct venipuncture.28
Needlestick Injuries
Seven publications reported data on needlestick injuries (NSIs), with none comparing NSI rates between device types. Reported NSI rates varied widely; they were lower in studies involving HCPs from developed countries,54,56,57,63 but higher in less developed countries.64-66
Limitations
The SLR was associated with some limitations because of data availability or ambiguous results. For example, because VADs used for blood collection are almost always used for other purposes (e.g., the infusion of medicines/fluids), it is difficult to establish a causal relationship between blood sampling and specific complications observed in patients. Further research is required to quantify the isolated risks associated with collecting blood from VADs.
No studies directly compared the occurrence of NSIs between VAD and direct venipuncture blood sampling; research is required to quantify the number of NSIs that could be avoided by collecting blood from indwelling VADs. In addition, no quantitative self-reported data were identified on anxiety, fear, or stress during VAD blood sampling. Further research is required to confirm the impact of collecting blood from indwelling VADs on patient (and potentially also HCP) anxiety, fear, or stress, compared with direct venipuncture. It is expected that collecting blood through an existing VAD would be less stressful for patients; Twibell et al.67 have reported significantly lower distress scores (p < .001) for PIVC relative to direct venipuncture blood collection, although their study was not eligible for the present SLR because distress scores were not self-reported. In fact, observer-rated distress (particularly needlestick distress in babies) is a well-researched topic that could warrant a future SLR in itself. Another interesting topic for a future SLR would be the reliability of different blood collection techniques for determining drug concentrations in plasma.
Finally, many of the identified publications offered limited description of the devices used. Where no further details were provided, the term “venipuncture” was assumed to be synonymous with direct venipuncture, but the term “phlebotomy” was not. It is possible that some of the included publications were misclassified as reporting on direct venipuncture alone, when in fact multiple devices were used and data were pooled across device types.
Discussion
This review involved a comprehensive search of the literature drawing on over a decade of published research, six major electronic databases, a broad range of study designs and prespecified outcomes, and no geographical limitations. For the purposes of this review, PIVCs and midline catheters were treated as distinct devices, but only 3/141 publications explicitly mentioned the use of midline catheters, relative to 53/141 for PIVCs, highlighting the lack of published data on midline catheters. Similarly, very few publications were identified on implanted ports (5/141 publications).
The data indicate that blood sampling from VADs is common in EDs, trauma centers, and ICUs; in these departments, the number of blood samples drawn from VADs often exceeds that from direct venipuncture, sometimes with a ratio as high as 4:1.22-24 However, where blood is to be collected specifically for culture, blood draw from indwelling VADs is widely discouraged, because of fears over sample contamination.15,17,30 These recommendations are important for the quality of care and based on historic data suggesting that contamination rates are higher in blood culture samples drawn from VADs compared with direct venipuncture.
Several studies showed that hemolysis and sample contamination place a considerable economic burden on hospitals, because patients may be required to stay in hospital longer, awaiting repeat test results. According to the data gathered in this review, both can be reduced through adherence to strict blood sampling protocols and use of the ISDT. According to a 2018 survey, 40% of US hospitals did not practice the ISDT for peripheral draws or central line draws,30 so regional/national interventions may be required to encourage its uptake.
Limited evidence was available on novel, needle-free blood collection devices, but the two publications included suggest that hemolysis rates may be lower in PIVO-collected blood samples than in samples collected by more established techniques.12,34 Educational programs are also known to decrease contamination of blood cultures and hemolysis rates.68
Conclusions
Blood is already collected from VADs in everyday clinical practice; this approach is most common in EDs, trauma centers, and ICUs, where patients are more likely to have had VADs inserted for other purposes such as the administration of fluids and medicines. Hemolysis and sample contamination are far from inevitable in VAD-collected or venipuncture samples; both can be reduced through adherence to strict blood sampling protocols and utilization of the ISDT. Needle-free blood collection devices offer further hope for reducing hemolysis, although few studies have been published to date. No publications focused specifically on the DIVA population; the benefits of VADs are likely to be higher in these patients.
Implications
Selecting the most optimal approach for blood sample collection is essential for ensuring high-quality healthcare. Healthcare quality professionals and organizational leaders should prioritize the implementation of safe and effective blood collection practices by considering various quality-related factors, including patient experience, provider safety, and delivery of prompt/appropriate care.
Our findings will be useful to hospital administrators, clinicians, and researchers striving for improved patient experience and health outcomes. Adherence to appropriate blood sampling protocols and utilization of the ISDT can reduce hemolysis and sample contamination, which may enable timely medical interventions.
Where blood sampling through VADs is indicated, this approach could offer multiple advantages, including fewer NSIs for providers and reduced anxiety for patients (and potentially HCPs), although these benefits remain to be objectively quantified by empirical research. Novel needle-free technologies may present further improvements in provider safety and patient experience. These benefits of VADs and needleless solutions (i.e., PIVO) will likely be greater in patients with DIVA.
Authors' Biographies
Cathy Perry DNP, is a nurse practitioner at Tennessee Oncology, Clarksville, TN.
Kimberly Alsbrooks BSN, is Sr. Director Medical Affairs at BD, Franklin Lakes, NJ.
Alicia Mares BSN, is Associate Director Medical Affairs at BD, Franklin Lakes, NJ.
Klaus Hoerauf MD, is professor of Anesthesiology and Intensive Care at the Medical University of Vienna, Vienna, Austria and VP Global Medical Affairs at BD, Franklin Lakes, NJ.
Supplementary Material
Acknowledgements
The authors recognize the valuable contributions of David Pritchett, Neil Webb, Amy Crompton, and Chris Hellmund, employees of Source Health Economics, the HEOR company that conducted the systematic literature review and provided writing services.
Footnotes
Funding was provided by BD for research and development of the manuscript, no separate funding was provided to the authors. The funding received from BD did not impact the results of the study.
K. Alsbrooks, A. Mares, and C. Perry designed and conceived the study and obtained research funding. K. Alsbrooks and K. Hoerauf supervised the conduct of the research and reviewed data collection. K. Alsbrooks, and K. Hoerauf managed the data, provided statistical advice, including quality control. All authors reviewed and revised the manuscript.
C. Perry declares no conflict of interest. K. Alsbrooks, A. Mares, and K. Hoerauf are employed by BD and also own stock in BD.
Ethical approval: Guarantor: K. Alsbrooks, 1 Becton Drive, Franklin Lakes, NJ 07417.
Supplemental digital content is available for this article. Direct URL citations appear in the printed text and are provided in the HTML and PDF versions of this article at (www.jhqonline.com).
Contributor Information
Cathy Perry, Email: cperry@tnonc.com.
Alicia Mares, Email: alicia.mares@bd.com.
Klaus Hoerauf, Email: klaus.hoerauf@bd.com.
References
- 1.OSG Research Funded by Becton Dickinson. 1928 General. BD Funded Research; 2020. [Google Scholar]
- 2.Green SF. The cost of poor blood specimen quality and errors in preanalytical processes. Clin Biochem. 2013;46(13-14):1175-1179. [DOI] [PubMed] [Google Scholar]
- 3.Cadacio C, Nachamkin I. A novel needle-free blood draw device for sample collection from short peripheral catheters. J Infusion Nurs. 2017;40(3):156-162. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.McLenon J, Rogers MAM. The fear of needles: A systematic review and meta-analysis. J Adv Nurs. 2019;75(1):30-42. [DOI] [PubMed] [Google Scholar]
- 5.Mulloy DF, Lee SM, Gregas M, Hoffman KE, Ashley SW. Effect of peripheral IV based blood collection on catheter dwell time, blood collection, and patient response. Appl Nurs Res. 2018;40:76-79. [DOI] [PubMed] [Google Scholar]
- 6.Bahl A, Johnson S, Alsbrooks K, Mares A, Gala S, Hoerauf K. Defining difficult intravenous access (DIVA): A systematic review. J Vasc Access. 2021. doi: 10.1177/11297298211059648. [DOI] [PubMed] [Google Scholar]
- 7.Guillon P, Makhloufi M, Baillie S, Roucoulet C, Dolimier E, Masquelier AM. Prospective evaluation of venous access difficulty and a near-infrared vein visualizer at four French haemophilia treatment centres. Haemophilia. 2015;21(1):21-26. [DOI] [PubMed] [Google Scholar]
- 8.Sebbane M, Claret PG, Lefebvre S, et al. Predicting peripheral venous access difficulty in the emergency department using body mass index and a clinical evaluation of venous accessibility. J Emerg Med. 2013;44(2):299-305. [DOI] [PubMed] [Google Scholar]
- 9.Guillon P, Makhloufi M, Baillie S, Roucoulet C, Dolimier E, Masquelier AM. Prospective evaluation of venous access difficulty and a near-infrared vein visualizer at four French haemophilia treatment centres. Haemophilia. 2015;21(1):21-26. [DOI] [PubMed] [Google Scholar]
- 10.Monteiro D, de la Torre-Montero J, Nicolussi A, Reis R, Barbosa M, Toffano S. Prevalence of and factors associated with difficult peripheral venipuncture in adult surgical patients. J Vasc Access. 2021;22(3):404-410. [DOI] [PubMed] [Google Scholar]
- 11.Zimmerman FS, Assous MV, Zevin S, Wiener-Well Y. Reducing blood culture contamination using an initial specimen diversion device. Am J Infect Control 2019;47(7):822-826. [DOI] [PubMed] [Google Scholar]
- 12.Natali R, Wand C, Doyle K, Noguez JH. Evaluation of a new venous catheter blood draw device and its impact on specimen hemolysis rates. Pract Lab Med. 2018;10:38-43. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Self WH, Speroff T, McNaughton CD, et al. Blood culture collection through peripheral intravenous catheters increases the risk of specimen contamination among adult emergency department patients. Infect Control Hosp Epidemiol. 2012;33(5):524-526. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Alahmadi YM, McElnay JC, Kearney MP, et al. Tackling the problem of blood culture contamination in the intensive care unit using an educational intervention. Epidemiol Infect. 2015;143(9):1964-1971. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Boyce JM, Nadeau J, Dumigan D, et al. Obtaining blood cultures by venipuncture versus from central lines: Impact on blood culture contamination rates and potential effect on central line-associated bloodstream infection reporting. Infect Control Hosp Epidemiol. 2013;34(10):1042-1047. [DOI] [PubMed] [Google Scholar]
- 16.McLaughlin LM, Inglis GDT, Hoellering AB, Davies MW. Relationship between blood culture collection method and proportion of contaminated cultures in neonates. J Paediatrics Child Health 2013;49(2):105-108. [DOI] [PubMed] [Google Scholar]
- 17.Woods-Hill CZ, Fackler J, Nelson McMillan K, et al. Association of a clinical practice guideline with blood culture use in critically ill children. JAMA Pediatr. 2017;171(2):157-164. [DOI] [PubMed] [Google Scholar]
- 18.Bush RA, Mueller T, Sumwalt B, Cox SA, Hilfiker ML. Assessing pediatric trauma specimen integrity. Am Soc Clin Lab Sci. 2010;23(4):219-222. [PubMed] [Google Scholar]
- 19.Barnard EBG, Potter DL, Ayling RM, Higginson I, Bailey AG, Smith JE. Factors affecting blood sample haemolysis: A cross-sectional study. Eur J Emerg Med. 2016;23(2):143-146. [DOI] [PubMed] [Google Scholar]
- 20.Berg JE, Ahee P, Berg JD. Variation in phlebotomy techniques in emergency medicine and the incidence of haemolysed samples. Ann Clin Biochem Int J Lab Med. 2011;48(6):562-565. [DOI] [PubMed] [Google Scholar]
- 21.Dietrich H. One poke or two: Can intravenous catheters provide an acceptable blood sample? A data set presentation, review of previous data sets, and discussion. J Emerg Nurs. 2014;40(6):575-578. [DOI] [PubMed] [Google Scholar]
- 22.Guihard B, Rouyer F, Serrano D, Sudrial J, Combes X. Appropriateness and complications of peripheral venous catheters placed in an emergency department. J Emerg Med. 2018;54(3):281-286. [DOI] [PubMed] [Google Scholar]
- 23.Lippi G, Bonelli P, Cervellin G. Prevalence and cost of hemolyzed samples in a large urban emergency department. Int J Lab Hematol. 2014;36(1):e24-e26. [DOI] [PubMed] [Google Scholar]
- 24.Ramakers C. BD Vacutainer Barricor tube in the emergency department: Reduced hemolysis rates using partial draw tubes with reduced vacuum. Clin Chem Lab Med. 2018;56(2):e31-e32. [DOI] [PubMed] [Google Scholar]
- 25.Bodley T, Chan M, Levi O, et al. Patient harm associated with serial phlebotomy and blood waste in the intensive care unit: A retrospective cohort study. PLoS ONE 2021;16(1):e0243782. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Kuriakose L. Decreasing central line associated bloodstream infection through limiting the use of central venous catheters for routine blood draws. J doctoral Nurs Pract. 2020;13(2):173-183. [DOI] [PubMed] [Google Scholar]
- 27.Tolan NV, Kaleta EJ, Fang JL, et al. Neonatal intensive care unit quality initiative: Identifying preanalytical variables contributing to specimen hemolysis and measuring the impact of evidence-based practice interventions. Am J Clin Pathol. 2016;146(1):113-118. [DOI] [PubMed] [Google Scholar]
- 28.Valentine SL, Bateman ST. Identifying factors to minimize phlebotomy-induced blood loss in the pediatric intensive care unit. Pediatr Crit Care Med. 2012;13(1):22-27. [DOI] [PubMed] [Google Scholar]
- 29.Beekmann SE, Diekema DJ, Huskins WC, et al. Diagnosing and reporting of central line-associated bloodstream infections. Infect Control Hosp Epidemiol. 2012;33(9):875-882. [DOI] [PubMed] [Google Scholar]
- 30.Garcia RA, Spitzer ED, Kranz B, Barnes S. A national survey of interventions and practices in the prevention of blood culture contamination and associated adverse health care events. Am J Infect Control. 2018;46(5):571-576. [DOI] [PubMed] [Google Scholar]
- 31.Berger-Achituv S, Budde-Schwartzman B, Ellis MH, Shenkman Z, Erez I. Blood sampling through peripheral venous catheters is reliable for selected basic analytes in children. Pediatrics. 2010;126(1):e179-e186. [DOI] [PubMed] [Google Scholar]
- 32.Braniff H, DeCarlo A, Haskamp AC, Broome ME. Pediatric blood sample collection from a pre-existing peripheral intravenous (PIV) catheter. J Pediatr Nurs. 2014;29(5):451-456. [DOI] [PubMed] [Google Scholar]
- 33.O'Neil SW, Friesen MA, Stanger D, Trickey AW. Survivability of existing peripheral intravenous access following blood sampling in a pediatric population. J Pediatr Nurs. 2018;41:90-95. [DOI] [PubMed] [Google Scholar]
- 34.Mulloy DF, Lee SM, Gregas M, Hoffman KE, Ashley SW. Effect of peripheral IV based blood collection on catheter dwell time, blood collection, and patient response. Appl Nurs Res. 2018;40:76-79. [DOI] [PubMed] [Google Scholar]
- 35.Barnaby DP, Wollowitz A, White D, et al. Generalizability and effectiveness of butterfly phlebotomy in reducing hemolysis. Acad Emerg Med. 2016;23(2):204-207. [DOI] [PubMed] [Google Scholar]
- 36.Giavarina D, Pasqualeb L, Mezzenaa G, Soffiatia G. Hemolysis by peripheral intravenous catheters: Materials comparison. Rivista Italiana della Medicina di Laboratorio 2010;6(3):216-221. [Google Scholar]
- 37.Hambleton VL, Gomez IA, Andreu FA. Venipuncture versus peripheral catheter: Do infusions alter laboratory results? J Emerg Nurs. 2014;40(1):20-26. [DOI] [PubMed] [Google Scholar]
- 38.Heiligers-Duckers C, Peters NALR, van Dijck JJ, Hoeijmakers JMJ, Janssen MJW. Low vacuum and discard tubes reduce hemolysis in samples drawn from intravenous catheters. Clin Biochem. 2013;46(12):1142-1144. [DOI] [PubMed] [Google Scholar]
- 39.Mattila OS, Harve H, Pihlasviita S, et al. Ultra-acute diagnostics for stroke: Large-scale implementation of prehospital biomarker sampling. Acta Neurol Scand. 2017;136(1):17-23. [DOI] [PubMed] [Google Scholar]
- 40.Munnix ICA, Schellart M, Gorissen C, Kleinveld HA. Factors reducing hemolysis rates in blood samples from the emergency department. Clin Chem Lab Med. 2011;49(1):157-158. [DOI] [PubMed] [Google Scholar]
- 41.Ortells-Abuye N, Busquets-Puigdevall T, Diaz-Bergara M, Paguina-Marcos M, Sanchez-Perez I. A cross-sectional study to compare two blood collection methods: Direct venous puncture and peripheral venous catheter. BMJ Open 2014;4(2):e004250. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Phelan MP, Reineks EZ, Schold JD, Hustey FM, Chamberlin J, Procop GW. Preanalytic factors associated with hemolysis in emergency department blood samples. Arch Pathol Lab Med. 2018;142(2):229-235. [DOI] [PubMed] [Google Scholar]
- 43.Straszewski SM, Sanchez L, McGillicuddy D, et al. Use of separate venipunctures for IV access and laboratory studies decreases hemolysis rates. Intern Emerg Med. 2011;6(4):357-359. [DOI] [PubMed] [Google Scholar]
- 44.Twibell KR, Hofstetter P, Siela D, Brown D, Jones HM. A comparative study of blood sampling from venipuncture and short peripheral catheters in pediatric inpatients. J Infusion Nurs. 2019;42(5):237-247. [DOI] [PubMed] [Google Scholar]
- 45.Wollowitz A, Bijur PE, Esses D, John Gallagher E. Use of butterfly needles to draw blood is independently associated with marked reduction in hemolysis compared to intravenous catheter. Acad Emerg Med. 2013;20(11):1151-1155. [DOI] [PubMed] [Google Scholar]
- 46.Jones RL, Sayles HR, Fey PD, Rupp ME. Effect of clinical variables on the volume of blood collected for blood cultures in an adult patient population. Infect Control Hosp Epidemiol. 2017;38(12):1493-1497. [DOI] [PubMed] [Google Scholar]
- 47.Kelly AM, Klim S. Taking blood cultures from a newly established intravenous catheter in the emergency department does not increase the rate of contaminated blood cultures. Emerg Med Australasia: EMA. 2013;25(5):435-438. [DOI] [PubMed] [Google Scholar]
- 48.Ramirez P, Gordón M, Cortes C, et al. Blood culture contamination rate in an intensive care setting: Effectiveness of an education-based intervention. Am J Infect Control. 2015;43(8):844-847. [DOI] [PubMed] [Google Scholar]
- 49.Santos CAQ, Shimasaki T, Kishen E, et al. Impact of phlebotomist-Only venipuncture and central line avoidance for blood culture in a large tertiary care university hospital. Infect Dis Clin Pract. 2018;26(2):91-96. [Google Scholar]
- 50.Stohl S, Benenson S, Sviri S, et al. Blood cultures at central line insertion in the intensive care unit: Comparison with peripheral venipuncture. J Clin Microbiol. 2011;49(7):2398-2403. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 51.Weddle G, Jackson MA, Selvarangan R. Reducing blood culture contamination in a pediatric emergency department. Pediatr Emerg Care. 2011;27(3):179-181. [DOI] [PubMed] [Google Scholar]
- 52.Hall RT, Domenico HJ, Self WH, Hain PD. Reducing the blood culture contamination rate in a pediatric emergency department and subsequent cost savings. Pediatrics. 2013;131(1):e292-e297. [DOI] [PubMed] [Google Scholar]
- 53.Kai M, Miyamoto K, Akamatsu K, Tsujita A, Nishio M. Effect of a bundle-approach intervention against contamination of blood culture in the emergency department. J Infect Chemother. 2020;26(8):785-789. [DOI] [PubMed] [Google Scholar]
- 54.Patton RG, Schmitt T. Innovation for reducing blood culture contamination: Initial specimen diversion technique. J Clin Microbiol. 2010;48(12):4501-4503. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55.Binkhamis K, Forward K, Bourbeau P. Effect of the initial specimen diversion technique on blood culture contamination rates. J Clin Microbiol. 2014;52(3):980-981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56.Lalezari A, Cohen MJ, Svinik O, et al. A simplified blood culture sampling protocol for reducing contamination and costs: A randomized controlled trial. Clin Microbiol Infect. 2020;26(4):470-474. [DOI] [PubMed] [Google Scholar]
- 57.Rupp ME, Cavalieri RJ, Marolf C, Lyden E. Reduction in blood culture contamination through use of initial specimen diversion device. Clin Infect Dis. 2017;65(2):201-205. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 58.Lancé MD, Henskens YMC, Nelemans P, et al. Do blood collection methods influence whole-blood platelet function analysis? Platelets. 2013;24(4):275-281. [DOI] [PubMed] [Google Scholar]
- 59.Atay A, Demir L, Cuhadar S, et al. Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors. Biochemia Med. 2014;24(3):376-382. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 60.Bhushan R, Sen A. Quantitative assessment of prevalence of pre-analytical variables and their effect on coagulation assay. Can intervention improve patient safety? Med J Armed Forces India. 2017;73(2):152-158. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 61.Goswami B, Singh B, Chawla R, Mallika V. Evaluation of errors in a clinical laboratory: A one-year experience. Clin Chem Lab Med. 2010;48(1):63-66. [DOI] [PubMed] [Google Scholar]
- 62.Skoglund E, Dempsey CJ, Chen H, Garey KW. Estimated clinical and economic impact through use of a novel blood collection device to reduce blood culture contamination in the emergency department: A cost-benefit analysis. J Clin Microbiol. 2019;57(1):e01015. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 63.Rees PSC, Lamb LEM, Nicholson-Roberts TC, et al. Safety and feasibility of a strategy of early central venous catheter insertion in a deployed UK military Ebola virus disease treatment unit. Intensive Care Med. 2015;41(5):735-743. [DOI] [PubMed] [Google Scholar]
- 64.Amini M, Behzadnia MJ, Saboori F, Bahadori M, Ravangard R. Needle-stick injuries among healthcare workers in a teaching hospital. Trauma Monthly. 2015;20(4):e18829. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 65.Shiva F, Sanaei A, Shamshiri AR, Ghotbi F. Survey of needle-stick injuries in paediatric health personnel of 5 University Hospitals in Tehran. JPMA J Pakistan Med Assoc. 2011;61(2):127-131. [PubMed] [Google Scholar]
- 66.Bashir B, Abdarabo A. Auditing of the phlebotomy system in medical laboratories in port Sudan city, Sudan. East Mediterr Health J. 2020;26(7):839-845. [Google Scholar]
- 67.Twibell KR, Hofstetter P, Siela D, Brown D, Jones HM. A comparative study of blood sampling from venipuncture and short peripheral catheters in pediatric inpatients. J Infusion Nurs. 2019;42(5):237-247. [DOI] [PubMed] [Google Scholar]
- 68.Gorski LA, Hadaway L, Hagle ME, et al. Infusion therapy standards of practice, 8th edition. J Infusion Nurs. 2021;44(1S):S1-S224. [DOI] [PubMed] [Google Scholar]