Skip to main content
. 2023 Jul 13;75(4):3639–3644. doi: 10.1007/s12070-023-04073-w

Table 4.

Means and standard deviations (SD) of speech intelligibility rating (SIR) and categories of auditory performance (CAP) scores of people with cochlear implants (CI) in time intervals of 6 to 24 months, based on level of education at time intervals of 6 to 24 months

CAP 24 CAP 18 CAP 12 CAP 6 SIR 24 SIR 18 SIR 12 SIR 6 Level of Education
49 49 49 49 49 49 49 49 n Illetrate
7.59 6.67 5.67 4.10 4.49 3.78 2.90 1.80 Mean
1.12 0.97 1.07 0.94 0.65 0.65 0.74 0.74 SD
94 94 94 94 94 94 94 94 N Elementary and middle school
7.13 6.22 5.18 3.89 4.11 3.51 2.76 1.62 Mean
1.50 1.42 1.47 1.39 0.98 1.05 1.10 0.96 SD
41 41 41 41 41 41 41 41 N High school and University
7.34 6.32 5.49 4.41 4.56 4.27 3.73 2.68 Mean
1.58 1.67 1.86 1.87 0.67 0.90 1.25 1.46 SD
0.213 0.297 0.217 0.388 0.008 0.000 0.000 0.000 P value