Abstract
Objectives
Respiratory protection is critical in healthcare to minimise the risk of airborne infections for healthcare workers (HCWs). It emphasizes the use of proper fitting of particulate filter respirators and equivalent respiratory protective equipment (RPE) to ensure a good facial seal. The systematic review aimed to compare the effectiveness of fit testing and fit checking for HCWs’ respiratory protective equipment.
Methods
A systematic review of the literature exploring RPE for HCWs to determine the effectiveness of fit-testing versus fit-checking from January 2003 to April 2022 was identified using CINAHL Complete via EBSCO Host, Cochrane Library, EMBASE, PubMed, and MEDLINE via Ovid electronic databases, and grey literature. The study protocol was registered with PROSPERO (registration number: CRD42020213968).
Results
Of the 561 articles identified in the search, 25 articles (22 quantitative studies and three guidelines) were included in this review. Overall, these studies suggest fit-testing as a method that is more effective, widely adopted, and reliable in assessing the effectiveness of RPE; however, a respiratory program should include both fit-testing and fit-checking to maximise effectiveness of the RPE. The COVID-19 epidemic highlighted a lack of knowledge among HCWs regarding fit-checking and fit-testing, and relevant education increased the effectiveness of respiratory equipment protection.
Conclusion
It is imperative that both fit-testing and fit-checking is implemented in order to ensure HCW safety. It is recommended to integrate education, fit-testing and fit-checking into a comprehensive respiratory protective program run by trained fit-testers. There is also a need for practical testing methods that incorporate the clinical environment.
Keywords: Fit-testing, Fit-checking, Healthcare personnel, Respiratory protective devices, Personal protective equipment, User seal check
What is known?
-
•
Healthcare workers (HCWs) are vulnerable to transmission of airborne pathogens; respiratory protective equipment is essential to provide HCW respiratory protection by use of a respirator, the most common being N95/P2 filtering facepiece respirators (FFRs) and powered air-purifying respirators.
-
•
N95/P2 or FFRs are intended to attain a close facial fit and effective filtration of airborne particles. All HCWs required to wear a N95/P2 respirator need to be educated on the significance of fit-checking and to know how to fit-check.
-
•
Annual fit-testing is recommended to comply with US s501025010 OSHA requirements and Australian and New Zealand Standard (AS/NZS) 1715:2009.
What is new?
-
•
Fit-testing is the more effective, most widely adopted and reliable method of assessing the effectiveness of respiratory protective equipment (RPE); however, fit-testing and fit-checking maximises the effectiveness of the RPE. There is also a need for testing methods that incorporate the environment in which the equipment will be used.
-
•
Additionally, participation and education of HCWs in the selectionand effectiveness tests of the protective equipment will increase the efficacy of protection and testing methods. Hospitals and policymakers are recommended to integrate education, fit-testing and fit-checking into a comprehensive respiratory protective program run by trained fit-testers.
1. Introduction
Healthcare associated infection (HAI) is a major concern within any hospital or healthcare setting. Healthcare workers (HCWs) are at risk of exposure to HAI [1]. The protection of HCWs from airborne diseases and infections is a priority within the healthcare system as it reduces the risk of HAI. The importance of monitoring and limiting airborne transmissible diseases has greatly increased more recently with emerging respiratory infectious diseases, including COVID-19 caused by Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) [1,2]. The COVID-19 pandemic has revealed deficiencies in global and Australian healthcare systems in the protection of HCWs from transmission of SARS-CoV-2 and other respiratory viruses [3]. For example, the supply of appropriate personal protective equipment (PPE) as well as testing and checking of PPE was delayed or insufficient [3]. A primary step in infection prevention and control is ensuring the effectiveness of respiratory protective equipment. This will help in preventing or limiting transmission of airborne pathogens. N95/P2 particulate respirators filter at least 95% of airborne particles, with the protection provided dependent on the filter’s efficiency and seal quality [4]. This is done through testing methods of varying efficacy. Two key methods utilised within the healthcare industry will be explored within this review: fit-testing and fit-checking/user seal testing. Fit-testing determines the brand, model, and size of the respirator that achieves an adequate seal on an individual’s face. There are two methods of fit-testing, which are quantitative and qualitative fit-testing.
The COVID-19 pandemic highlighted significant deficiencies in global healthcare systems in the protection of HCWs from transmission of COVID-19 and other respiratory pathogens [3]. Transmission of SARS-CoV-2 in healthcare settings has been a major issue throughout the COVID-19 pandemic worldwide, especially during the first waves in 2020 [5]. In Australia, for example, during the first wave in the state of Victoria, 22% of HCWs who tested positive for SARS-CoV-2, the virus that causes COVID-19, reportedly acquired the virus through workplace transmission [6]. However, this increased to at least 69% during the second wave, highlighting the urgent need for better protection for front-line HCWs [3]. The prevalence of infection among HCWs worldwide varied from 0.3% to 43.3% [5]. The COVID-19 pandemic is also responsible for significant loss of life among HCWs, with the WHO estimating 80,000 to 180,000 HCW deaths globally, and these figures may be underreported [5]. Among hospitalized patients with confirmed COVID-19, up to 41% were infected in healthcare settings, according to different studies [5]. As new strains of COVID-19 emerge and are identified, HCWs will continue to be faced with the need for continued respiratory protection. Due to the risk of infection and mortality for HCWs and patients, determining the effectiveness of fit testing versus checking is urgently needed.
Qualitative fit-testing is influenced by the wearer; it uses a test agent such as saccharin or Bitrex (a bitter tasting substance). This agent enables the user to sense the presence of the test agent within the respirator by taste, smell, or the urge to cough if the fit of the respiratory protective equipment (RPE) is not adequate [6]. Quantitative fit-testing requires the use of specialized particle counting equipment (such as PortaCount™ Plus machine) to provide numerical measurements called fit factor. The PortaCount™ Plus machines work by measuring the concentration of microscopic dust particles in the ambient air and then measuring the concentration of those dust particles that leak into the respirator. The ratio of these two concentrations is called the fit factor [6,7]. A fit factor value of 100 or greater is the criterion for achieving a pass for a disposable N95/P2 respirator [8]. The more reliable method of measuring effectiveness would be one that is quantitative, as it removes the wearer’s individual influence [9]. See Table 1 for a summary of the procedures involved in these methods.
Table 1.
Fit testing and fit checking procedures.
| Fit testing | Fit checking |
|---|---|
|
Fit-testing involves qualitative and quantitative fit-testing. Qualitative fit-testing is influenced by the wearer; it uses a test agent such as saccharin or Bitrex (a bitter-tasting substance), which is used at a sensitivity level that demonstrates the user will be able to appropriately sense the presence of the test agent within the respirator by taste, smell, or the urge to cough if the fit of the RPE is not adequate [8]. Quantitative fit-testing requires the use of specialized particle counting equipment (such as PortaCount™ Plus machine) to provide numerical measurements called fit factor. These machines measure the concentration of microscopic dust particles in the ambient air and those dust particles that leak into the respirator. The ratio of these two concentrations is called the fit factor and a value of 100 or greater is the criterion for achieving a pass for a disposable N95/P2 respirator [[6], [7], [8]]. |
Fit-checking or user seal checking is a process conducted to ensure that the RPE creates a facial seal to minimise the number of particles that bypass the filter through gaps between the wearer’s skin and the respirator seal and is performed each time it is used [2]. The user dons the respirator and checks the user seal as per the manufacturer’s instructions, ensuring there are no folds, creases or hair around the edges. The nose piece is moulded (not pinched) to the user’s nose bridge and cheekbones. The fit check is then performed as per the respirator manufacturer’s instruction. Fit checking or user seal check ensures a good respirator fit by checking facial seal over the bridge of the nose and securely covering the mouth and chin with no gaps between the respirator. |
Note: RPE = Respiratory protective equipment.
Regardless of the method used to determine fit-testing, user seal checking is required to be performed by the individuals each time a respirator is used. Fit-checking or user seal checking is a process conducted to ensure that the RPE creates a facial seal to minimise the number of particles that bypass the filter through gaps between the wearer’s skin and the respirator seal and is performed each time it is used [2].
This systematic review aimed to answer the research question: Effectiveness of fit-testing versus fit-checking for HCW respiratory protective equipment. The protocol for this review is registered in PROSPERO under the registration number CRD42020213968, available at https://www.crd.york.ac.uk/prospero/.
2. Methods
A systematic review to identify research exploring RPE for HCWs was undertaken to determine the reported effectiveness of fit-testing versus fit-checking. This review was guided by an integrated approach in accordance with the JBI methodology for mixed methods systematic reviews using JBI SUMARI [10]. This involved assembling the qualitised data from quantitative studies with the qualitative data. Assembled data was categorised and pooled together based on similarity in meaning to produce a set of integrated findings. Reporting of this systematic review complied with Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines [11]. The records of screened articles were recorded in a PRISMA flowchart in Fig. 1. The Mixed Methods Appraisal Tool (MMAT) was used to assess the relevance and results of the included studies. The MMAT was used to screen articles based on several screening questions that helped identify the quality and clarity of the articles based on the analysis that was conducted [12].
Fig. 1.
Flow diagram of the systematic review process.
2.1. Data collection
A comprehensive and systematic search of 5 databases, including CINAHL Complete via EBSCO Host, Cochrane Library, EMBASE, PubMed, and MEDLINE via Ovid, was conducted. A search of grey literature, including international guidelines and standards relevant to respiratory protection, was also undertaken. A health research librarian was consulted to develop the search strategy in the initial stages. The reference lists of identified studies and grey literature were screened, and citation tracking was also performed to identify further literature. The search was limited to studies available in English from 2003 to April 2022 in order to capture previous literature related to respiratory pandemics, such as severe acute respiratory syndrome (SARS), Middle East respiratory syndrome (MERS), and the COVID-19 pandemic.
The search strategy included various combinations of Medical Subject Headings (MeSH) terms and keywords identified in the first search. These included but were not limited to Fit test∗, Mask∗, Respirator∗, User seal check∗ and health profession/doctor/nurse/clinician, allied health, or hospital. These articles were then exported to Endnote version 20.2.1.15749 and further screened using the inclusion and exclusion criteria. Inclusion criteria sought studies from any geographical location published in English between January 2003 and April 2022. A range of study types (quantitative, qualitative, and mixed methods, and grey literature) that examined health care worker fit-checking and fit-testing of N95/P2 respiratory protective equipment were included. Studies focusing on non-healthcare worker occupational groups (mining, building, and construction) and conference abstracts, reviews, editorials, commentaries, or policy statements were excluded.
2.2. Study selection
Two reviewers (CG and PZ) independently screened the title and abstracts of studies against inclusion and exclusion criteria; discrepancies were resolved by a third reviewer (MM). Studies for inclusion were critically appraised using the MMAT, and suitable studies were collated in a data extraction table. Data to be extracted included type of study, participants, location of study, aims and objectives, study design and methods, and findings.
2.3. Data analysis
A data extraction table was developed for extracting data for the review. All data items extracted were cross-checked by PZ to ensure relevant articles are included. Due to the heterogeneity of the included studies, the findings are presented as a narrative synthesis [13].
3. Results
The database search of articles from January 2003 to April 2022 returned 512 articles; 49 additional records were identified through other sources. Of the database search, 76 articles remained as full text review following a review of the titles and abstracts and the exclusion of duplicates. After screening the 76 articles against the study’s inclusion and exclusion criteria, 54 articles were excluded. Of the 49 other records, three met the criteria and were included in the review. As indicated in the PRISMA diagram (Figs. 1), 22 articles from the database search and three documents (guidelines) from other searches met the inclusion criteria and were included in the final systematic review.
Of the 22 quantitative studies [1,3,4,8,[14], [15], [16], [17], [18], [19], [20], [21], [22], [23], [24], [25], [26], [27], [28], [29], [30], [31]] identified in Table 2, five were from Korea, six from China, five from Australia, and six from the United States. Seven of the studies reviewed on the effectiveness of facial seals were quantitative studies. Chan et al. [8] was the only observational study conducted within a hospital setting; all other studies were conducted in a simulation environment. The MMAT was used to appraise the methodological quality of the included quantitative studies in this systematic review. The 22 quantitative studies met the criteria; however, some of the chosen methodologies impacted the quality of the study. Three geographical documents (guidelines) [2,6,32] are listed in Table 3.
Table 2.
Summary of studies included in the review.
| Authors, year, and country | Study design/method | Participants | Type of respirator and fit testing measure | Findings | Limitations | MMAT |
|---|---|---|---|---|---|---|
| Kim. et al. (2019) [1] Korea | Quantitative randomized crossover study Fit checking process not defined |
22 participants | 3M − 1860, 1860S, 1870, and 9332; Portacount Plus |
|
This study did not investigate the sustained effect of training. | All criteria for quantitative randomised criteria met. |
| Regli et al. (2021) [3] Australia | Quantitative non-randomised Convenience sample Fit checking process defined |
53 anesthetists, 31 anesthetic technicians | Proshield N95 respirator medium and small; Sensitivity testing, Portacount Plus |
|
The method or order of fit-testing was not controlled. | Criteria 3.1, 3.4, 3.5 for quantitative non-randomised studies not met. |
| Williams et al. (2021) [4] Australia | Prospective randomised crossover study Fit checking process defined |
96 anesthetic staff, 26% South-East Asian ethnicity | Two duckbill models N95 respirators (Halyard Fluidshield and BSN ProShield); Portacount plus |
|
Only two types of respirators were used. | Criteria 2.4 for quantitative randomised studies not met. |
| Chan et al. (2021) [8] Australia | Quantitative observational study Fit checking process defined |
58 HCWs | 3 M − 8210, 8110S, 1860, 1860S N95- Proshield and Halyard; PortaCountTM Model 8048 machine |
|
Lack of applicable respirator fit failure rate from the scientific literature prevented any sample size calculation to look for a comparative effect. | All criteria for quantitative non-randomised studies met. |
| Danyluk et al. (2011) [14] USA | Quantitative non-randomised study Fit checking process defined |
784 HCWs | 3M − 1860, 1860S, and 1870; Portacount plus |
|
83% of participants were naïve users of respirators. | All criteria for quantitative non-randomised studies met. |
| Huh et al. (2018) [15] Korea | Quantitative Non-randomised Fit checking process defined |
211 military hospital HCWs | 3M − 1860/1860S and 1870+, Maskin MS 6115 (K–C) 46727; PortaCount Pro+ 8038 |
|
Subjects were recruited from a single military hospital. | Criteria 3.1 for quantitative non- randomised studies not met. |
| Sietsema & Brosseau (2018) [16] USA | Quantitative Non-randomised study Fit checking process defined |
7 male, 8 female | 3M − 1860 or 1860s; Portacount Plus Model 8020 and an electrostatic classifier |
|
Only one manufacturer’s models were employed. | Criteria 3.1 for quantitative non-randomised studies not met. |
| Winter et al. (2010) [17] Australia | Quantitative Non-randomised study Fit checking process not defined |
50 healthy hospital staff volunteers | K–C Fluid Shield N95, 3M − 9320 and 8822 with exhalation valve 3 M Qualitative Taste fit test kits F10 and F30 |
|
Participants attitude towards the respirators may have influenced their taste threshold and thus the result of the test. | All criteria for quantitative non-randomised studies met. |
| Duling et al. (2007) [18] USA | Quantitative Non-randomised Fit checking process not defined |
37 female, 20 male | N95- elastomeric and filtering-facepiece, and SM Portacount plus model 8020 |
|
The exercise regime used may not be representative of all actual workplace movements. | All criteria for quantitative non-randomised studies met. |
| Derrick et al. (2005) [19] China | Quantitative non-randomised study Fit checking process defined |
N95 masks (1860s) – 2 female, 2 male; N95 masks (9210) – 81 female, 12 male; N100 mask (8233)–79 female, 12 male | N95-1860s and 9210, N100- 8233; PortaCount Plus |
|
Only three different respirators were tested. | All criteria for quantitative non-randomised criteria studies met. |
| Lam et al. (2016) [20] China | Quantitative descriptive, prospective, and cross-sectional research design. Fit checking process defined |
638 nursing students | 3M-1860s, 1862, and K–C 46827; PortaCount Pro+, Respirator Fit Tester 8038 |
|
Only two types of respirators were used. | Criteria 3.1 and 3.4 for quantitative non-randomised studies not met. |
| Or et al. (2016) [21] China | Quantitative Randomised study Fit checking process defined |
84 nursing students, ranging 18–21 years old | N95 Respirator. Portacount Plus |
|
The experiment used would not totally reflect the real working situation. | Criteria 2.4 for quantitative randomised studies not met. |
| Lee et al. (2017) [22] Korea | Quantitative randomized crossover study Fit checking process defined |
25 healthcare providers | 3M − 1860, 1860S, 1870, and 9332. |
|
Only one model of respirator was used. | Criteria 2.4 for quantitative randomised studies not met. |
| Lam et al. (2011) [23] China | Quantitative descriptive, prospective, and cross-sectional research design Fit checking process defined |
204 nursing students, 18–23 years, male 21.6% | Respirators- 3 M 1860S, and 3 M 1862. Portacount Pro |
|
Participants were all student nurses. | Criteria 3.1 and 3.4 for quantitative non-randomised studies not met. |
| Hwang et al. (2020) [24] Korea | Quantitative non-randomised simulation study Fit checking process defined |
14 medical doctors, 23 nurses, and 7 emergency medical technicians; 29 female | N95 respirator PortaCount Pro+ 8038 |
|
Participants were instructed not to talk as much as possible. | Criteria 3.4 for quantitative non- randomised studies not met. |
| Hauge et al. (2012) [25] USA | Quantitative Non-randomised Fit checking process not defined |
8 registered nurses; 6 female, 2 male | 3M − 1860 or 1860S, N95 filtering facepiece respirator. Two Portacount Plus (Model 8020) with N95-Companion (Model 8095) instruments |
|
Sample size was small. | All criteria for quantitative non- randomised criteria met. |
| Viscusi et al. (2012) [26] USA | Quantitative Non-randomised study Fit checking process defined |
11; 5 female, 6 male | 3 M–1860, 1870, and K–C PFR95-270. Portacount Plus |
|
The study sample was small. | All criteria for quantitative non-randomised studies met. |
| Myong et al. (2016) [27] Korea | Quantitative non-randomised study Fit checking process defined |
50 senior medical students | Vflex 9102, Vflex 9102S, 3 M 1870, and SM 82001 Portacount Pro Plus 8038 |
|
Only one qualitative fit-testing method was used instead of two due to previous reports of side effects with the bitter test kit. | Criteria 3.4 for quantitative non-randomised studies not met. |
| Milosevic et al. (2022) [28] Australia | Quantitative non-randomised study Fit checking process not defined |
6,451 HCWs aged 18–84 1 | 3 M 1860, 3 M 1860S, 3 M 1970+, 3 M 8110S, 3 M 8210, PortaCount Pro + Respirator Fit Tester 8038 |
|
Does not aid the prediction of which respirator models are better suited to specific individuals. | Does not aid the prediction of which respirator models are better suited to specific individua + G87ls. |
| Suen et al. (2020) [29] China | Quantitative Non-randomised experimental study Fit checking process not defined |
104 nursing students; 83 female, 21 male | 3 M − 1860, 1860S and 1870 PortaCount Plus |
|
Participants did not have experience using N95 respirators in clinical settings. | All criteria for quantitative non-randomised studies met. |
| Suen et al. (2017) [30] China | Quantitative Non-randomised study Fit checking process not defined |
120 nursing students; 98 female, 22 male | 3M − 1860, 1860S, and 1870+ Portacount Plus |
|
Participants lacked experience using N95 respirators in clinical settings. | All criteria for quantitative non-randomised studies met. |
| McMahon et al. (2021) [31] USA | Quantitative randomised study Fit checking process not defined |
Physicians, 105 fit-tests performed over the course of 49 shifts | EFMs with disposable filters (N95, P95, or P100). Qualitative fit testing using standardized hood and 3 M FT-32 bitter testing solution. |
|
Donning and doffing procedures were not observed and may impact fit or function. | Criteria 3.2, 3.3, 3.4, 3.5 for quantitative randomised studies not met |
Note: APG = all passed group. EFMs = elastomeric face masks. FFR = filtering facepiece respirator. HCWs = healthcare workers. K–C = Kimberly Clark. OMMC = overall moisture management capacity. OWTC = one-way transport capacity. PPG = partially passed group. PPV = positive pressure ventilation. QLFT = qualitative fit test. QNFT = quantitative fit test. RPE = respiratory protective equipment. RPP = respiratory protection program. SM = surgical mask. SWFF = simulated workplace for factor. SWPF = simulated workplace protection factor. USC = user seal check.
Table 3.
Grey literature.
| Origin of Document | Aim | Method | Included in the guideline |
|---|---|---|---|
| Victoria State Government, (2020) [6] | To outline why a RPP should be implemented within health services, what is required to implement a RPP and the roles and responsibilities of employees and employers | Quantitative fit testing | The effectiveness of close-fitting respiratory protection relies on achieving a seal against the wearer’s face. The purpose of fit-testing is to verify which selected respirator makes, models, and sizes of close-fitting RPE adequately fit the wearer. |
| South Australia [SA] Health, (2020) [32] | This document provides information and guidance to workers and employers regarding respiratory protection against airborne infectious diseases. | Quantitative fit testing | For a P2/N95 respirator to provide maximum protection, it is essential that the wearer be properly fitted and trained in its safe use. A risk management approach should be applied to ensure that workers working in high-risk areas are fit-tested and know how to perform a fit-check. |
| Clinical Excellence Commission [CEC], (2022) [2] | This guidance document focuses on respiratory protection in relation to the use of respirators and what is required to ensure these are managed, worn and used safely. | Qualitative and quantitative tests | Fit-testing is a validated method that determines the brand and size of respirator that achieves an adequate seal on an individual’s face. Although there are a number of published studies that show that fit-testing will detect air leakage in respirators that have passed a fit-check, the evidence base for showing fit-testing reduces risk of infection in HCWs is currently very limited and equivocal. |
Note: HCWs = healthcare workers. RPP = respiratory protection program.
In this review, three main themes emerged; ‘Methods to determine facial seal’ which focused on the effectiveness of fit testing and fit checking; ‘effectiveness of healthcare worker training’ focused on how effective education/training is to achieving a good facial seal, and ‘contextual nature of determining a seal’ which explored the validity of facial seal assessment based on the context that evaluation occurred.
3.1. Methods to determine facial seal
A predominant focus within the included literature was facial seal effectiveness, particularly the methods used to determine how effective facial seals are both in normal fit-testing/checking sessions and in simulated work activities. The two assessments mentioned within the included studies were fit-testing and fit-checking, and the procedures for these tests are outlined earlier in the paper in Table 1.
Six studies in this review looked at the effectiveness of fit-testing [2,8,[14], [15], [16], [17]]. Fit-testing is identified as an important element of respiratory protection programs to ensure the wearer is issued a respirator that is the correct size, provides a good facial seal and gives an adequate level of protection [8,18]. Fit-testing also provides an educational opportunity for the user to improve respirator seal [8].
Excluding fit-testing and relying strictly on a user fit-check is disputed by Danyluk et al. [14] due to this method incorrectly indicating a proper fit on several occasions or incorrectly indicating a properly fitting respirator as defined by a fit-test. In a study by Derrick et al. [19] the user felt that the respirator fitted when the observed fit factor was very low. Fit-checking is inadequate for detecting gross leakage in donning N95/P2 respirators; therefore, fit-checking is not an appropriate surrogate for respirator fit-testing [14,19,20]. Fit-testing is recommended to be used to determine the fit of N95/P2 respirators, and a user seal check must be done in a well-defined respiratory program including fit-checking [14,20]. Lam et al. [20] recommended that quantitative fit-testing be used to determine the fit of N95 respirators.
3.2. Effectiveness of healthcare worker training
The effectiveness of fit-testing and fit-checking is dependent upon the reliability and quality of the measures used. The COVID-19 pandemic highlighted a lack of knowledge among HCWs regarding fit-checking and fit-testing, and this led to HCWs undergoing education regarding respiratory protection, fit-testing, and proper fit-checking principles, which increased the effectiveness of respiratory equipment protection [3]. Training healthcare providers in respiratory protection could significantly improve the fit factor and adequate protection rate [1]. Furthermore, proper protection performance of the respirator during fit-testing was improved after training [1]. Or, Chung & Wong [21] study supports the role of ongoing education in fit-checking. Chan et al. [8] recommend hospitals and policymakers integrate education, fit-testing, and fit-checking into a comprehensive respiratory protective program.
3.3. Contextual nature of determining a seal
The contextual nature of fit-testing/checking poses some challenges to the effectiveness of fit-tests. Fit-testing is generally not being tested in hospitals and other actual practice conditions where there is also a high risk of airborne disease transmission [1,15,16,17, 20,24,22,23). This lack of contextual testing means that although N95/P2 respirators passed the fit-test, in high-risk situations, such as during cardiopulmonary resuscitation where wearers are performing chest compressions, there is no guaranteed protection against respiratory infections [27]. To tackle this issue, a new fit-test, personal respirator sampling test (PRST), has been proposed, which can be undertaken whilst the wearer performs clinical activities, and the detection of face seal leakage can be monitored [21]. If implemented, the PRST can help wearers evaluate the actual performance of their respirators during HCW activities in the clinical setting [21]. The use of PRST is supported by Hauge et al. [25] and Viscusi et al. [26], who suggest that an initial fit-test during a simulated task could be a better way of ensuring the effectiveness of fit-tests.
4. Discussion
This study identified the effectiveness of fit-testing compared to fit-checking for HCW RPE. The findings in studies from Australia, China, Korea, and USA produced three themes: 1) methods to determine facial seal, 2) effectiveness of healthcare worker training, and 3) contextual nature of determining a seal. The COVID-19 pandemic highlighted the need for the education of HCWs regarding fit-testing and proper fit-checking protocols, which subsequently allowed for the increased effectiveness of respiratory equipment protection [3].
Seven studies from various Australian tests reviewed the effectiveness of fit-testing and collected quantitative data that showed the importance and effectiveness of fit-testing when either paired with fit-checking or as a stand-alone method. Additionally, education on fit-testing plays a crucial role in increasing the effectiveness of HCW protection, especially in China [3,8]. However, overall, these studies lack an assessment of the retention rates of education over time [8]. Further repeat studies with fit-testing education integrated with a respiratory protection program would be highly beneficial to hospitals and policy makers [8].
Another point from Korea discussed the importance of the type of RPE chosen that ensures adequate protection [27]. During the education component of the study by Myong et al. [27], there is a strong emphasis on educating HCWs on the type of RPE and the type of protection each affords after conducting a fit-test. This re-occurring theme suggests the importance of the type of RPE that is explored by various professionals and academics, such as in the study of Korea Lee et al. [22], that the type of respirator can influence the protective performance of healthcare providers. Furthermore, simulation studies from Korea by Kim et al. [1] revealed that training HCWs in a respiratory protection program may significantly improve the fit factor and adequate protection rate of the three types of respirators. To further establish this, the introduction of fit training, whereby HCWs are initially given training on fit-checking and fit-testing at the time of employment, then refreshed annually as per the Australian Standard (AS/NZS 1715:2009) or during a global pandemic. This would be beneficial to the safety of HCWs by ensuring that a chosen respirator will provide a good facial seal, as indicated by studies from Korea and Australia [1,3,28].
The contextual nature whereby fit-testing occurs also poses some challenges to the effectiveness of fit-tests. In China, fit-testing is not being tested in high activity roles where there is also a high risk of airborne disease transmission [29]. This lack of contextual testing, as shown from Korea in the table above, means that although certain types of respirators, such as the N95/P2, passed the fit-test, in high-risk situations, such as during chest compressions, this did not guarantee protection against respiratory infections [24]. To address this problem, a new fit-test (PRST) has been proposed that can be undertaken whilst the wearer performs clinical activities and where the detection of face seal leakage can be monitored. Multiple studies from Australia demonstrated that the use of an initial fit-test during a simulated task could be a better way in ensuring their effectiveness of fit-tests [20,30]. This idea of multi-phase tests, especially in the USA, is supported by Viscusi et al. [26], who suggest there are benefits to performing a user seal check on some models for HCWs who have previously passed a fit-test for those same respirator models.
Upon further analysis of fit-testing and fit-checking policies, Chughtai et al. [33] do raise a concerning issue that despite Australian guidelines outlining fit-checking policies, at the ground level, these guidelines are not necessarily translating into practice. Chughtai et al. [33] conducted a study using twenty healthcare workers in which most participants were not aware of the hospital respiratory protection policies. Furthermore, participants reported that they had not received any training nor had they participated in a fit-test prior to the study [24]. It was found that this was secondary to the limited role that HCWs play in the selection of respirators. Consequently, supporting the idea that for the effectiveness of any of the methods of testing to increase, the context in which the tests are conducted is highly important. By using practicing HCWs to test and select the respiratory protective equipment, it allows for educational opportunities that benefit the hospital and the HCW simultaneously [24]. Hospitals must not only implement but also educate their HCWs on these policies and conduct fit-tests that allow HCWs to be involved in decision making regarding what protective equipment should be supplied [6,31,32].
It can be argued that in USA and Korea if hospitals are to conduct fit-tests to help determine the type of respiratory equipment to use, then a better model would be to implement facial seal checks in various hospital settings to complement fit-testing and ensure good facial seal is achieved each time a respirator is worn [14,27,34]. This then allows for the effectiveness of the tests to be quantified in a context in which the participants would ultimately be using the equipment. This would not only ensure that HCWs could be assured regarding the quality or facial seal effectiveness of respiratory protection used but also be confident in the effectiveness.
4.1. Limitations
The search was limited to only studies available in English; this may have led to selection bias due to the inclusion of only a subset of papers creating an incomplete data set. The Cochrane Handbook acknowledges the risk of bias in otherwise high-quality reviews when non-English studies are not included [34]. Furthermore, some studies had small sample sizes, which may limit the power and generalisability of the study findings. Some studies also used a single model of respirator to contact fit-testing due to shortages of respirators during the COVID-19 pandemic. Whilst the discussion tried to compare fit testing and fit checking it’s difficult to separate the two processes as they are all important processes to ensure safety and protection from infections, that in itself became a limitation to this study.
4.2. Recommendations and implications for practice
A respiratory protection program is vital and should include staff education and training in fit-testing and fit-checking to ensure a good seal is achieved in order to reduce HCWs’ risk of exposure. For the ongoing safety of HCWs, fit-testing, fit-checking, and education can be completed during staff induction and annually as per the Australian standard (AS/NZS 1715:2009) or/and during global pandemics. Future repeat studies incorporating education as a part of fit-testing integrated with a Respiratory Protection Program (RPP) are needed to assess retention rates of education over time. The two processes cannot be separated as they are components of the respiratory protection program.
5. Conclusion
Fit-testing is identified as an important element of RPE to ensure the wearer uses a correct size respirator that provides a good facial seal and gives an adequate level of protection. Moreso, fit checking is recommended at the point of use; therefore, used together, fit testing and fit checking maximise the effectiveness of the RPE. Multiple studies in Australia, USA, Korea, and China using various quantitative and qualitative methods highlighted that fit-testing and fit-checking education and training for HCWs improves the effectiveness of respirators. Achieving good facial seal improves the fit factor. There is also a need for testing methods that incorporate the environment in which the equipment will be used. The two are not the same yet they are part of the respiratory program to achieve an effective facial seal. Comparatively, fit checking is done each time a respirator is worn whilst fit testing is done at least once per annum. Additionally, participation and education of HCWs in the selection and effectiveness tests of the protective equipment will increase the effectiveness of protection and testing methods. Hospitals and policymakers are recommended to integrate education, fit-testing, and fit-checking into a comprehensive respiratory protective program run by trained fit-testers.
Ethical consideration
This review used data from published studies therefore ethics approval was not required or sought.
Funding
Nothing to declare.
Data availability statement
The datasets generated during and/or analyzed during the current study are available from the corresponding author upon reasonable request.
CRediT authorship contribution statement
Charlotte Goko: Conceptualization, Methodology, Validation, Formal analysis, Investigation, Data curation, Writing - original draft, Writing – review & editing, Project administration. Elizabeth Forster: Conceptualization, Methodology, Validation, Formal analysis, Investigation, Resources, Data curation, Writing – review & editing, Supervision, Project administration. Matthew Mason: Conceptualization, Methodology, Validation, Formal analysis, Investigation, Resources, Writing – review & editing, Supervision. Peta-Anne Zimmerman: Conceptualization, Methodology, Validation, Formal analysis, Investigation, Resources, Data curation, Writing – review & editing, Supervision, Project administration.
Declaration of competing interest
We have no conflicts of interest to disclose.
Acknowledgement
We would like to acknowledge the Griffith University librarians for their expertise and assistance during data collection of this research.
Footnotes
Peer review under responsibility of Chinese Nursing Association.
Supplementary data to this article can be found online at https://doi.org/10.1016/j.ijnss.2023.09.011.
Appendix A. Supplementary data
The following is the Supplementary data to this article:
References
- 1.Kim H., Lee J., Lee S., Oh J., Kang B., Lim T.H., et al. Comparison of fit factors among healthcare providers working in the Emergency Department Center before and after training with three types of N95 and higher filter respirators. Medicine. 2019;98(6) doi: 10.1097/MD.0000000000014250. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Clinical Excellence Commission [CEC] Respiratory protection program manual. https://www.cec.health.nsw.gov.au/__data/assets/pdf_file/0004/696712/Respiratory-Protection-Program-Manual.pdf
- 3.Regli A., Thalayasingam P., Bell E., Sommerfield A., von Ungern-Sternberg B.S. More than half of front-line healthcare workers unknowingly used an N95/P2 mask without adequate airborne protection: an audit in a tertiary institution. Anaesth Intensive Care. 2021;49(5):404–411. doi: 10.1177/0310057X211007861. [DOI] [PubMed] [Google Scholar]
- 4.Williams D.L., Kave B., Lee K., Segal R., Krieser R.B., Mezzavia P.M., et al. A randomised crossover study to compare the user seal check and quantitative fit test between two types of duckbill N95 particulate respirator masks: the Halyard Fluidshield® N95 and the BSN Medical ProShield® N-95 particulate respirator masks. Anaesth Intensive Care. 2021;49(2):112–118. doi: 10.1177/0310057X20974022. [DOI] [PubMed] [Google Scholar]
- 5.World Health Organisation Global report on infection prevention and control. https://www.who.int/news/item/06-05-2022-who-launches-first-ever-global-report-on-infection-prevention-and-control
- 6.Victoria State Government Protecting our healthcare workers. https://www.dhhs.vic.gov.au/sites/default/files/documents/202010/Protecting-our-healthcare-workers-action-plan.pdf
- 7.TSI Incorporated Portacount® pro 8030 and Portacount® pro+ 8038 respirator fit testers. https://tsi.com/getmedia/76df3dbb-6d8d-4d78-aa24-5aff19e889e9/8030_8038_PortaCountPro_Manual_6001868
- 8.Chan J.K., Yep K.H., Magarey S., Keon-Cohen Z., Acheson M. Fit testing disposable P2/N95 respirators during COVID-19 in Victoria, Australia: fit check evaluation, failure rates, and a survey of healthcare workers. COVID. 2021;1(1):83–96. doi: 10.3390/covid1010007. [DOI] [Google Scholar]
- 9.O'Kelly E., Arora A., Pirog S., Ward J., Clarkson P.J. Comparing the fit of N95, KN95, surgical, and cloth face masks and assessing the accuracy of fit checking. PLoS One. 2021;16(1) doi: 10.1371/journal.pone.0245688. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Lizarondo L, Stern C, Carrier J, Godfrey C, Rieger K, Salmond S, et al. Chapter 8: Mixed methods systematic reviews.In: Aromataris E, Munn Z, eds. JBI Manual for Evidence Synthesis. [Accessed 14 January 2022]. https://synthesismanual.jbi.global/.
- 11.Page M.J., McKenzie J.E., Bossuyt P.M., Boutron I., Hoffmann T.C., Mulrow C.D., et al. Updating guidance for reporting systematic reviews: development of the PRISMA 2020 statement. J Clin Epidemiol. 2021;134:103–112. doi: 10.1016/j.jclinepi.2021.02.003. [DOI] [PubMed] [Google Scholar]
- 12.Hong Q.N., Gonzalez-Reyes A., Pluye P. Improving the usefulness of a tool for appraising the quality of qualitative, quantitative and mixed methods studies, the Mixed Methods Appraisal Tool (MMAT) J Eval Clin Pract. 2018;24(3):459–467. doi: 10.1111/jep.12884. [DOI] [PubMed] [Google Scholar]
- 13.Ryan R. Cochrane consumers and communication review group. ‘Cochrane consumers and communication review group: data synthesis and analysis’. http://cccrg.cochrane.org
- 14.Danyluk Q., Hon C.Y., Neudorf M., Yassi A., Bryce E., Janssen B., et al. Health care workers and respiratory protection: is the user seal check a surrogate for respirator fit-testing? J Occup Environ Hyg. 2011;8(5):267–270. doi: 10.1080/15459624.2011.566016. [DOI] [PubMed] [Google Scholar]
- 15.Huh Y.J., Jeong H.M., Lim J., Park H.Y., Kim M.Y., Oh H.S., et al. Fit characteristics of N95 filtering facepiece respirators and the accuracy of the user seal check among koreans. Infect Control Hosp Epidemiol. 2018;39(1):104–107. doi: 10.1017/ice.2017.271. [DOI] [PubMed] [Google Scholar]
- 16.Sietsema M., Brosseau L.M. Are quantitative fit factors predictive of respirator fit during simulated healthcare activities? J Occup Environ Hyg. 2018;15(12):803–809. doi: 10.1080/15459624.2018.1515490. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Winter S., Thomas J.H., Stephens D.P., Davis J.S. Particulate face masks for protection against airborne pathogens - one size does not fit all: an observational study. Crit Care Resusc. 2010;12(1):24–27. [PubMed] [Google Scholar]
- 18.Duling M.G., Lawrence R.B., Slaven J.E., Coffey C.C. Simulated workplace protection factors for half-facepiece respiratory protective devices. J Occup Environ Hyg. 2007;4(6):420–431. doi: 10.1080/15459620701346925. [DOI] [PubMed] [Google Scholar]
- 19.Derrick J.L., Chan Y.F., Gomersall C.D., Lui S.F. Predictive value of the user seal check in determining half-face respirator fit. J Hosp Infect. 2005;59(2):152–155. doi: 10.1016/j.jhin.2004.09.009. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Lam S.C., Lui A.K.F., Lee L.Y.K., Lee J.K.L., Wong K.F., Lee C.N.Y. Evaluation of the user seal check on gross leakage detection of 3 different designs of N95 filtering facepiece respirators. Am J Infect Control. 2016;44(5):579–586. doi: 10.1016/j.ajic.2015.12.013. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Or P., Chung J., Wong T. A novel approach to fit testing the N95 respirator in real time in a clinical setting. Int J Nurs Pract. 2016;22(1):22–30. doi: 10.1111/ijn.12354. [DOI] [PubMed] [Google Scholar]
- 22.Lee S., Kim H., Lim T., Oh J., Kang H., Ahn C., et al. Simulated workplace protection factors for respirators with N95 or higher filters for health care providers in an emergency medical centre: a randomized crossover study. Hong Kong J Emerg Med. 2017;24(6):282–289. [Google Scholar]
- 23.Lam S.C., Lee J.K.L., Yau S.Y., Charm C.Y.C. Sensitivity and specificity of the user-seal-check in determining the fit of N95 respirators. J Hosp Infect. 2011;77(3):252–256. doi: 10.1016/j.jhin.2010.09.034. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Hwang S.Y., Yoon H., Yoon A., Kim T., Lee G., Jung K.Y., et al. N95 filtering facepiece respirators do not reliably afford respiratory protection during chest compression: a simulation study. Am J Emerg Med. 2020;38(1):12–17. doi: 10.1016/j.ajem.2019.03.041. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Hauge J., Roe M., Brosseau L.M., Colton C. Real-time fit of a respirator during simulated health care tasks. J Occup Environ Hyg. 2012;9(10):563–571. doi: 10.1080/15459624.2012.711699. [DOI] [PubMed] [Google Scholar]
- 26.Viscusi D.J., Bergman M.S., Zhuang Z.Q., Shaffer R.E. Evaluation of the benefit of the user seal check on N95 filtering facepiece respirator fit. J Occup Environ Hyg. 2012;9(6):408–416. doi: 10.1080/15459624.2012.683757. [DOI] [PubMed] [Google Scholar]
- 27.Myong J.P., Byun J., Cho Y., Seo H.K., Baek J.E., Koo J.W., et al. The education and practice program for medical students with quantitative and qualitative fit test for respiratory protective equipment. Ind Health. 2016;54(2):177–182. doi: 10.2486/indhealth.2015-0072. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Milosevic M., Kishore Biswas R., Innes L., Ng M., Mehmet Darendeliler A., Wong A., et al. P2/N95 filtering facepiece respirators: results of a large-scale quantitative mask fit testing program in Australian health care workers. Am J Infect Control. 2022;50(5):509–515. doi: 10.1016/j.ajic.2021.12.016. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Suen L.K.P., Guo Y.P., Ho S.S.K., Au-Yeung C.H., Lam S.C. Comparing mask fit and usability of traditional and nanofibre N95 filtering facepiece respirators before and after nursing procedures. J Hosp Infect. 2020;104(3):336–343. doi: 10.1016/j.jhin.2019.09.014. [DOI] [PubMed] [Google Scholar]
- 30.Suen L.K.P., Yang L., Ho S.S.K., Fung K.H.K., Boost M.V., Wu C.S.T., et al. Reliability of N95 respirators for respiratory protection before, during, and after nursing procedures. Am J Infect Control. 2017;45(9):974–978. doi: 10.1016/j.ajic.2017.03.028. [DOI] [PubMed] [Google Scholar]
- 31.McMahon K., Jeanmonod D., Check R., Rivard L., Balakrishnan V., Kelly B., et al. The pragmatic use of industrial elastomeric facemasks in health care practice during the COVID-19 pandemic. Am J Emerg Med. 2021;48:273–275. doi: 10.1016/j.ajem.2021.05.025. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.South Australia [SA] Health Respiratory protection against airborne infectious diseases clinical guideline. https://www.sahealth.sa.gov.au/wps/wcm/connect/0aca9a80423727cc9e0efeef0dac2aff/Clinical_Directive_Respiratory_Protection_+Against_Airborne_Infectious_Diseases_v1.4_22.06.2020.pdf?MOD=AJPERES& CACHEID=ROOTWORKSPACE-0aca9a80423727cc9e0efeef0dac2aff-oe79
- 33.Ahmad Chughtai A, Seale H, Rawlinson WD, Kunasekaran M, Macintyre CR. Selection and use of respiratory protection by healthcare workers to protect from infectious diseases in hospital settings. Ann Work Expo Health. 2020;64(4):368–377. doi: 10.1093/annweh/wxaa020. [DOI] [PubMed] [Google Scholar]
- 34.Neimann Rasmussen L., Montgomery P. The prevalence of and factors associated with inclusion of non-English language studies in Campbell systematic reviews: a survey and meta-epidemiological study. Syst Rev. 2018;7(1):129. doi: 10.1186/s13643-018-0786-6. [DOI] [PMC free article] [PubMed] [Google Scholar]