Blood and urine aluminium concentrations were studied in industrially exposed workers using electrothermal atomic absorption spectrometry. Welders and workers making aluminium powder and aluminium sulphate had higher concentrations in blood and urine than non-exposed referents. Workers in the electrolytic production of aluminium had higher urine but not blood concentrations than the referents. Thus aluminium was found to be absorbed by all industrially exposed workers. Blood concentrations were lower than those presumably associated with aluminium induced encephalopathy in patients receiving dialysis.

Full text

PDF
301

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Alderman F. R., Gitelman H. J. Improved electrothermal determination of aluminum in serum by atomic absorption spectroscopy. Clin Chem. 1980 Feb;26(2):258–260. [PubMed] [Google Scholar]
  2. Alfrey A. C., Hegg A., Craswell P. Metabolism and toxicity of aluminum in renal failure. Am J Clin Nutr. 1980 Jul;33(7):1509–1516. doi: 10.1093/ajcn/33.7.1509. [DOI] [PubMed] [Google Scholar]
  3. Elliott H. L., Dryburgh F., Fell G. S., Sabet S., Macdougall A. I. Aluminium toxicity during regular haemodialysis. Br Med J. 1978 Apr 29;1(6120):1101–1103. doi: 10.1136/bmj.1.6120.1101. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Gorsky J. E., Dietz A. A. Determination of aluminum in biological samples by atomic absorption spectrophotometry with a graphite furnace. Clin Chem. 1978 Sep;24(9):1485–1490. [PubMed] [Google Scholar]
  5. Kaehny W. D., Hegg A. P., Alfrey A. C. Gastrointestinal absorption of aluminum from aluminum-containing antacids. N Engl J Med. 1977 Jun 16;296(24):1389–1390. doi: 10.1056/NEJM197706162962407. [DOI] [PubMed] [Google Scholar]
  6. Kovalchik M. T., Kaehny W. D., Hegg A. P., Jackson J. T., Alfrey A. C. Aluminum kinetics during hemodialysis. J Lab Clin Med. 1978 Nov;92(5):712–720. [PubMed] [Google Scholar]
  7. MCLAUGHLIN A. I., KAZANTZIS G., KING E., TEARED, PORTER R. J., OWEN R. Pulmonary fibrosis and encephalopathy associated with the inhalation of aluminium dust. Br J Ind Med. 1962 Oct;19:253–263. doi: 10.1136/oem.19.4.253. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Masselot J. P., Adhemar J. P., Jaudon M. C., Kleinknecht D., Galli A. Reversible dialysis encephalopathy: role for aluminium-containing gels. Lancet. 1978 Dec 23;2(8104-5):1386–1387. doi: 10.1016/s0140-6736(78)92031-7. [DOI] [PubMed] [Google Scholar]
  9. Poisson M., Mashaly R., Lebkiri B. Dialysis encephalopathy: recovery after interruption of aluminium intake. Br Med J. 1978 Dec 9;2(6152):1610–1611. doi: 10.1136/bmj.2.6152.1610. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Rosati G., De Bastiani P., Gilli P., Paolino E. Oral aluminum and neuropsychological functioning. A study of dialysis patients receiving aluminum hydroxide gels. J Neurol. 1980;223(4):251–257. doi: 10.1007/BF00313339. [DOI] [PubMed] [Google Scholar]
  11. Valentin H., Preusser P., Schaller K. H. Die Analyse von Aluminium im Serum und Urin zur Uberwachung exponierter Personen. Int Arch Occup Environ Health. 1976 Oct 21;38(1):1–17. doi: 10.1007/BF00378316. [DOI] [PubMed] [Google Scholar]

Articles from British Journal of Industrial Medicine are provided here courtesy of BMJ Publishing Group

RESOURCES