Abstract
Background
Peripheral lung lesions can be sampled using various techniques, including computer tomography-guided transthoracic needle aspiration, electromagnetic navigation bronchoscopy, virtual navigation bronchoscopy, and radial probe endobronchial ultrasound transbronchial lung biopsy. Mediastinal lesions can be sampled using techniques like convex probe endobronchial ultrasound-guided transbronchial needle aspiration (CEBUS-TBNA) and endoscopic ultrasound-fine-needle aspiration. However, effective, safe techniques for lesions adjacent to the segmental or subsegmental bronchi are lacking. Herein, we retrospectively evaluated the diagnostic yield and safety of radial probe endobronchial ultrasound-assisted transbronchial needle aspiration (REBUS-TBNA) for lesions adjacent to the segmental bronchi, and explored the factors related to diagnostic yield.
Methods
We retrospectively analyzed the diagnostic yield and safety of REBUS-TBNA cases performed in our department from January 2019 to December 2022. Observation group patients had undergone REBUS-TBNA for lesions adjacent to the segmental bronchi; control group patients had undergone CEBUS-TBNA for mediastinal or hilar lesions. Patient characteristics and lesion sizes, diagnostic yield, adverse events, and relations between diagnostic yield and clinical characteristics were analyzed.
Results
There were not statistically significant between-group differences in sex, age, diagnostic yield, or rate of adverse events. The observation group (n = 25; 17 male, 8 female) had a mean age of 64.76 ± 10.75 years. The average lesion size was 4.66 ± 1.07 cm, and lesions were predominantly in the upper lobes (80%). REBUS-TBNA diagnostic yield was 84%, with no adverse events reported. Diagnostic yield was not associated with lesion size or extent of bronchial stenosis; however, it was positively correlated with number of punctures. Patients with > 3 punctures had a significantly higher diagnostic yield than those with ≤ 3 punctures.
Conclusions
REBUS-TBNA is a safe, effective diagnostic technique, particularly for lesions adjacent to the segmental or subsegmental bronchi of the upper lobe. Performing more than three punctures during the procedure improves the diagnostic yield. Larger-scale studies are warranted to confirm these results, and to further explore the clinical value of REBUS-TBNA.
Keywords: Radial probe endobronchial ultrasound (REBUS), Convex probe endobronchial ultrasound (CEBUS), Transbronchial needle aspiration (TBNA), Segmental bronchi, Diagnostic yield
Background
The COVID-19 pandemic increased the prevalence of lung computed tomography (CT) examinations [1, 2]. The rate of detecting lung nodules, pulmonary masses, and mediastinal masses has also increased significantly. Techniques like non-invasive liquid biopsy test, computer tomography-guided transthoracic needle aspiration (CT-TTNA), electromagnetic navigation bronchoscopy (ENB), virtual navigation bronchoscopy (VNB), and radial probe endobronchial ultrasound-assisted transbronchial lung biopsy (REBUS-TBLB), are used to sample peripheral lung tissue lesions [3–9]. For mediastinal lesions, techniques like convex probe endobronchial ultrasound-guided transbronchial needle aspiration (CEBUS-TBNA) and endoscopic ultrasound-fine-needle aspiration are used [10–14]. However, for lesions located in the segmental or subsegmental bronchi from the 3rd − 5th order (i.e., not peripheral or mediastinal regions), CEBUS and endoscopic ultrasound (EUS) are usually inadequate. CT-TTNA is high-risk, with complication rates up to 40% and pneumothorax rates of 25%, and carries a significantly higher occurrence of pneumothorax in lesions in the distal chest wall compared with those in the proximal chest wall [4–7]. Since these lesions typically do not involve the airway mucosa, TBLB and brushing techniques are also unsuitable. Therefore, effective, safe techniques are urgently needed for the diagnosis of segmental or subsegmental bronchi-adjacent lesions.
EBUS is a bronchoscopic examination technique that utilizes ultrasound to visualize the airway wall, lung, and mediastinal structures. It includes convex probe EBUS (CEBUS) and radial probe EBUS (REBUS).
CEBUS-TBNA is a cutting-edge technology that has emerged in the last two decades as a highly effective diagnostic tool. Specifically, it excels in identifying enlarged mediastinal and hilar lymph nodes (LNs) in patients exhibiting benign or malignant conditions through CT or positron emission tomography-CT (PET-CT). Numerous clinical studies have attested to its efficacy, noting that it is both cost-effective and safe in procuring diagnostic specimens. In fact, its diagnostic yield is often comparable to, or even surpasses, that of surgical mediastinoscopy. The applications of CEBUS-TBNA are vast and include diagnosing intrapulmonary tumors, determining LN staging in lung cancer patients, uncovering unexplained hilar and/or mediastinal LN enlargement, and pinpointing mediastinal tumors [10–14].
Contrastingly, there is a dearth of published studies focusing on radial probe EBUS-assisted transbronchial needle aspiration (REBUS-TBNA) [15, 16]. On the other hand, a plethora of research has been conducted on REBUS-TBLB, [17–21]. REBUS technique involves the insertion of an independent ultrasound probe into the bronchial lumen through the working channel of the bronchoscope. This device is characterized by non-embedded, non-real-time monitoring, and circular scanning capabilities. While REBUS-TBNA enables access to more distant and finer bronchi, its primary limitation lies in the inability to provide real-time monitoring during the puncture procedure. Table 1 comprehensively outlines the main differences between CEBUS-TBNA and REBUS-TBNA techniques.
Table 1.
CEBUS-TBNA vs. REBUS-TBNA comparison
| CEBUS-TBNA | REBUS-TBNA | |
|---|---|---|
| Flexibility of bronchoscope for view | 60° | 360° |
| Real time TBNA potential | Yes | No |
| Doppler mode potential | Yes | No |
| Ultrasound probe frequency* | 5–12 MHz | 20 MHz |
| Tissue Penetration | Low | High |
*Higher frequency leads to better resolution and image quality and less penetration; low-frequency leads to better penetration but lower resolution (i.e., lower quality) images
For segmental or subsegmental bronchi-adjacent lesions that are inaccessible via CEBUS-TBNA but can be reached by flexible bronchoscopy, REBUS-TBNA plays an important role [15, 16]. However, there are currently limited reports on the diagnostic efficacy and safety of this technique. Thus, in this retrospective study, we aimed to evaluate the diagnostic efficacy and safety of REBUS-TBNA for segmental and subsegmental bronchi-adjacent lesions, and to explore factors that may affect diagnostic yield.
Methods
Patients
This retrospective study included patients who underwent REBUS-TBNA and CEBUS-TBNA in the Department of Respiratory and Critical Care Medicine at our hospital between January 1, 2019, and December 31, 2022. The patients included in the observational group were those who had undergone REBUS-TBNA to access lesions adjacent to segmental or subsegmental bronchi that were deemed unreachable by CEBUS-TBNA. Typically, various factors such as the device status, consumables batch, operator, and gender can potentially influence study results. To minimize confounding factors, the control group has established inclusion criteria that require enrolling the first or second CEBUS-TBNA patient (due to incomplete or missing medical records of the first patient) with the same operator and gender following every REBUS-TBNA patient. The exclusion criterion is that patients with incomplete or missing medical records are not eligible for the study. Included patients’ final diagnosis was based on cytology, histopathology, microbiology examination, imaging findings, and clinical features.
Equipment
The following equipment, all produced by Olympus Corporation, Tokyo, Japan, was used: bronchoscope (BF-1T260), flexible bronchoscope (BF-260), EBUS bronchoscope (BF-UC260FW), bronchoscope main unit (BF-CLV-260), intracavitary ultrasound main unit (EndoEcho EU-ME2), intracavitary ultrasound probe (UM-S20-17 S), and 22G WANG TBNA needle (NA-201SX-4022).
Protocol
Prior to the procedure, preoperative discussions were held, and the operating physician reviewed the patient’s chest CT images to determine legion size(s) and location(s). Preoperative preparations followed routine procedures for bronchoscopy, including a six-hour fasting period. Before the procedure, lidocaine nebulization and topical anesthesia with lidocaine jelly were administered to the pharynx, and the patient received continuous oxygen supplementation during the examination, while vital signs were monitored.
REBUS-TBNA
A flexible bronchoscope was inserted through the nose, and the target location was explored to observe the extent of bronchial stenosis and whether the mucosa was involved. Then, the radial probe ultrasound probe was passed through the working channel of the bronchoscope into the bronchial lumen, and a detailed examination was performed to determine the optimal puncture location and depth. The flexible bronchoscope was fixed, and the radial probe ultrasound probe was withdrawn. A puncture needle was then inserted and adjusted to the previously determined optimal puncture location and depth. After entering the lesion, the inner stylet was withdrawn, and a negative pressure syringe was connected. The puncture needle was moved back and forth 20 times without X-ray fluoroscopy. The number of needle passes for each lesion ranged from 1 to 5, depending on factors such as patient tolerance, bleeding, and specimen quality. Obtained specimens were used for histopathological examination, liquid-based cytology, microbiology examination, and, as needed, immunohistochemistry, special staining, and pathogen metagenomic next-generation sequencing (mNGS) tests.
CEBUS-TBNA
A regular bronchoscope was inserted through the nose to observe the mucosa of the bronchial lumen in detail. Then, an ultrasound bronchoscope was inserted through the mouth, and the convex probe ultrasound probe was advanced near the lesion. Under real-time ultrasound guidance, the probe was brought close to the airway wall, and the distal balloon was inflated with 0.5–1 ml of normal saline to fill the bronchus. Lymph nodes were identified and measured, and the optimal puncture point was determined to avoid puncturing large blood vessels. A puncture needle was then inserted through the working channel of the bronchoscope. After entering the lesion, the inner stylet was withdrawn, and a negative pressure syringe was connected. The puncture needle was moved back and forth 20 times. The number of needle passes for each lesion ranged from 1 to 5. Obtained specimens were used for histopathological examination, liquid-based cytology, microbiology examination, and, as needed, immunohistochemistry, special staining, and pathogen mNGS tests.
Patients who received a definitive diagnosis via EBUS-TBNA (e.g., tumor, tuberculosis, sarcoidosis, fungal infection) were defined as positive. Patients who could not receive a definitive diagnosis were defined as negative.
In case of post-procedure bleeding, diluted epinephrine or cold saline was used for local hemostasis. After confirming no active bleeding, the procedure was completed. Postoperative adverse events, such as worsening cough, chest pain, pneumothorax, bleeding/hemoptysis requiring clinical intervention, new-onset/worsening hypoxemia, and death, were recorded.
Statistical analysis
Data were analyzed using SPSS Statistics version 23 (IBM, Armonk, NY, USA). Continuous variables are expressed as mean ± standard deviation, and categorical variables are presented as frequencies and percentages. Independent-samples t-tests were used to compare between-group age distributions. Fisher’s exact probability test was used to compare between-groups diagnostic yield and incidence of adverse events. Clinical characteristics for patients with different diagnoses (“positive” or “negative”) were compared using fisher’s exact probability test. A p-value < 0.05 was considered statistically significant.
Results
Patient characteristics
A total of 25 patients were included in the observational group (Table 2). Among them, 17 were male and 8 were female, with a mean age of 64.76 ± 10.75 years. The control group (Table 3) included 25 patients, with 17 males and 8 females, and a mean age of 60.44 ± 9.56 years. There were not statistically significant gender or age differences between the groups (p > 0.05).
Table 2.
Clinical characteristics of REBUS-TBNA patients
| No. | Sex | Age | Lesion diameter (cm) | Lesion location | Extent | No. punctures | Pathology | Diagnosis | Adverse events |
|---|---|---|---|---|---|---|---|---|---|
| 1 | F | 73 | 6.2 | RML B4 | Mild | 4 | Inflammation | P | NO |
| 2 | F | 62 | 2.8 | LUL B4 | Mild | 4 | Inflammation | P | NO |
| 3 | F | 72 | 4.3 | LUL B4b | Mild | 4 | Adenocarcinoma | P | NO |
| 4 | F | 68 | 2.4 | LUL B4 | Mild | 2 | Blood | N | NO |
| 5 | M | 82 | 3.7 | RUL B3 | Atretic | 5 | Squamous Carcinoma | P | NO |
| 6 | F | 69 | 4.1 | RUL B2 | Mild | 5 | Adenocarcinoma | P | NO |
| 7 | M | 64 | 5 | RUL B3 | Mild | 5 | Inflammation | P | NO |
| 8 | F | 59 | 4.9 | LUL B4 | Atretic | 3 | ND | N | NO |
| 9 | M | 64 | 3.8 | LUL B1 + 2 | Mild | 4 | SCLC | P | NO |
| 10 | M | 77 | 5.3 | RML B5 | Mild | 4 | Adenocarcinoma | P | NO |
| 11 | M | 70 | 3.8 | RUL B3 | Mild | 5 | Adenocarcinoma | P | NO |
| 12 | M | 77 | 6.1 | RML B4 | Mild | 3 | Blood | N | NO |
| 13 | M | 69 | 4.5 | RUL B2 | Atretic | 5 | Granuloma | P | NO |
| 14 | M | 56 | 4.7 | RUL B3 | Atretic | 5 | Granuloma | P | NO |
| 15 | M | 78 | 5.2 | RLL B10 | Mild | 3 | ND | N | NO |
| 16 | F | 60 | 6 | RUL B2 | Mild | 5 | SCLC | P | NO |
| 17 | M | 55 | 4.8 | LUL B1 + 2 | Mild | 4 | SCLC | P | NO |
| 18 | M | 29 | 3 | LUL B1 + 2 | Mild | 5 | Granuloma | P | NO |
| 19 | M | 62 | 4.1 | RUL B2 | Mild | 4 | Adenocarcinoma | P | NO |
| 20 | M | 55 | 5.2 | RUL B3 | Mild | 5 | Adenocarcinoma | P | NO |
| 21 | F | 62 | 4.6 | RUL B2 | Atretic | 4 | SCLC | P | NO |
| 22 | M | 67 | 5.6 | RUL B3 | Mild | 5 | Adenocarcinoma | P | NO |
| 23 | M | 53 | 4.3 | LLL B10 | Mild | 5 | Adenocarcinoma | P | NO |
| 24 | M | 65 | 6.7 | RUL B2 | Mild | 5 | Adenocarcinoma | P | NO |
| 25 | M | 71 | 5.3 | RUL B3 | Mild | 5 | SCLC | P | NO |
M: male; F: female; RUL: right upper lobe; RML: right middle lobe; RLL: right lower lobe; LUL: left upper lobe; LLL: left lower lobe; Extent: extent of bronchial stenosis; Atretic: bronchi is atretic; SCLC: small cell lung cancer; ND: non-diagnostic; P: positive diagnosis; N: negative diagnosis
Table 3.
Clinical characteristics of CEBUS-TBNA patients
| No. | Sex | Age | Lesion location | Pathology | Diagnosis | Adverse events |
|---|---|---|---|---|---|---|
| 1 | F | 71 | #4R, mass | Adenocarcinoma | P | NO |
| 2 | F | 62 | #4R, mass | Small cell lung cancer | P | NO |
| 3 | F | 67 | #7, #11R, mass | Granuloma | P | NO |
| 4 | F | 52 | #7, mass | Granuloma | P | NO |
| 5 | M | 78 | #4R, #7 | Small cell lung cancer | P | NO |
| 6 | F | 51 | #7, #11R | Granuloma | P | NO |
| 7 | M | 65 | #4R, #7, #11R | Adenocarcinoma | P | NO |
| 8 | F | 44 | mass | Granuloma | P | NO |
| 9 | M | 57 | mass | Squamous Carcinoma | P | NO |
| 10 | M | 58 | #7 | Adenocarcinoma | P | NO |
| 11 | M | 56 | #7, mass | Adenocarcinoma | P | NO |
| 12 | M | 59 | #7, #11L | Adenocarcinoma | P | NO |
| 13 | M | 62 | #4R, #7, #4L | Small cell lung cancer | P | NO |
| 14 | M | 58 | #4R, mass | Small cell lung cancer | P | NO |
| 15 | M | 75 | #11R | Inflammation | P | NO |
| 16 | F | 50 | #4R, mass | Granuloma | P | NO |
| 17 | M | 51 | #4R, mass | Adenocarcinoma | P | NO |
| 18 | M | 73 | #7, #11R, mass | Inflammation | P | Transient |
| 19 | M | 56 | #7, mass | Adenocarcinoma | P | NO |
| 20 | M | 71 | #4R, #7 | Granuloma | P | NO |
| 21 | F | 49 | #7, #11R | ND | N | NO |
| 22 | M | 48 | #4R, #7, #11R | ND | N | NO |
| 23 | M | 72 | mass | Adenocarcinoma | P | NO |
| 24 | M | 56 | mass | Inflammation | P | NO |
| 25 | M | 70 | #7 | Granuloma | P | NO |
M: male; F: female; ND: non-diagnostic; P: positive diagnosis; N: negative diagnosis; Transient: transient worsening cough
In the observational group, the average lesion size was 4.66 ± 1.07 cm, and they were mainly located in the upper lobes of both lungs, with 7 cases (28%) in the left upper lobe, 13 cases (52%) in the right upper lobe, 3 cases (12%) in the right middle lobe, and 1 case (4%) each in the right and left lower lobes. All lesions were inaccessible via CEBUS-TBNA due to anatomical structures or severe bronchial stenosis. The extent of bronchial stenosis was mainly mild (20 cases, 80%), with a small number of cases showing complete external occlusion (5 cases, 20%). The median number of punctures was 4 times (note that performing as many punctures as possible to obtain sufficient specimens was recommended). The 5 patients who underwent fewer than the median number of punctures were due to poor patient tolerance, difficulty with lesion puncturing, and bleeding risk. Pathology results included tumors (15 cases, 60%), inflammation (3 cases, 12%), granulomas (3 cases, 12%), blood clots (2 cases, 8%), and non-diagnostic samples (2 cases, 8%). Patients with blood clots (2 cases) and non-diagnostic samples (2 cases), combined clinical features and other tests, were ultimately not diagnosed.
In the control group, all lesions were located in the mediastinum or hilum. Pathology results consisted of tumors (13 cases, 52%), granulomas (7 cases, 28%), inflammation (3 cases, 12%), and non-diagnostic samples (2 cases, 8%). The patients with non-diagnostic samples (2 cases), combined clinical features and other tests, were ultimately not diagnosed.
Diagnostic yield and incidence of adverse events
In the observational group (Table 4), there were 21 confirmed cases and 4 undiagnosed cases, resulting in a diagnostic yield of 84%. In the control group (Table 4), there were 23 confirmed cases and 2 undiagnosed cases, resulting in a diagnostic yield of 92%. There was not a statistically significant between-group difference in the diagnostic yield (p > 0.05).
Table 4.
Diagnostic yield and incidence of adverse events
| Group | Positive | Negative | Total | P value |
|---|---|---|---|---|
| Diagnosis | ||||
| REBUS-TBNA | 21 | 4 | 25 (84%) | 0.667 |
| CEBUS-TBNA | 23 | 2 | 25 (92%) | |
| Adverse events | ||||
| REBUS-TBNA | 0 | 25 | 25 (0) | 1 |
| CEBUS-TBNA | 1 | 24 | 25 (4%) |
The incidence of adverse events in the observational group (Table 4) was 0. In the control group (Table 4), the incidence of adverse events was 4%, with 1 patient experiencing mild exacerbation of cough within 24 h, which resolved quickly without intervention. There was not a statistically significant between-group difference in the incidence of adverse events (p > 0.05).
No other complications occurred during the procedures in either group, except for minor bleeding at the puncture site. Nor were there any postoperative cases of chest pain, pneumothorax, clinically significant bleeding/hemoptysis, new-onset or worsened hypoxemia, or deaths in either group.
Relations between diagnostic yield and clinical characteristics
The diagnostic yield of REBUS-TBNA (Table 5) was unassociated with lesion size or the extent of bronchial stenosis (p > 0.05). However, there was significant, positive correlation with number of punctures, with patients who underwent > 3 punctures having a significantly higher diagnostic yield than those who underwent ≤ 3 punctures (p < 0.05).
Table 5.
Relations between diagnostic yield and clinical characteristics
| Group | Positive | Negative | Total | P value |
|---|---|---|---|---|
| Lesion diameter | ||||
| ≥ 4.7 cm | 10 | 3 | 13 (76.9%) | 0.593 |
| < 4.7 cm | 11 | 1 | 12 (91.7%) | |
| Times | ||||
| ≤ 3 | 0 | 3 | 3 (0) | 0.002 |
| > 3 | 21 | 1 | 22 (90%) | |
| Extent | ||||
| Mild | 17 | 3 | 20 (70%) | 1 |
| Atretic | 4 | 1 | 5 (80%) |
Positive: positive diagnosis; Negative: negative diagnosis; Times: number of punctures; Extent: extent of bronchial stenosis; Atretic: bronchi is atretic
Discussion
REBUS-TBNA access to adjacent lesions of the upper lobe segmental and subsegmental bronchi
CEBUS-TBNA is a widely used efficacious, minimally invasive technique for staging lung cancer and obtaining samples from mediastinal and hilar lymph nodes/masses. In addition to its uses in malignant diseases, it is also the preferred diagnostic method for non-malignant conditions such as tuberculosis, sarcoidosis, and fungal infections [22–24]. However, CEBUS-TBNA limitations (Tables 1 and 6) include sampling lesions in the upper lobe, due to anatomical structures and angles [25, 26].
Table 6.
Advantages and limitations of REBUS-TBNA vs. CEBUS-TBNA
| REBUS-TBNA | CEBUS-TBNA | |
|---|---|---|
| Advantages |
1. Large bendable angle 2. Reach more distant and finer bronchi |
1. Real-time monitoring 2. Doppler mode |
| Limitations | non-real-time monitoring | Poor accessibility of upper lobe lesions or distal lesions |
| Unique indications |
1. Lesions in segmental or subsegmental bronchi 2. Peripheral pulmonary lesions |
Mediastinal or hilar lesions |
Techniques including CT-TTNA, ENB-TBLB, VNB-TBLB, and REBUS-TBLB have been used to sample peripheral lesions of the upper lobe. However, sampling lesions adjacent to the segmental or subsegmental bronchi of the upper lobe remains challenging. CEBUS-TBNA is often unable to reach these locations, CT-TTNA has a high complication rate, and techniques like TBLB and brush biopsy are not ideal because these lesions typically do not involve the airway mucosa. In contrast, REBUS-TBNA is an effective, safe method that overcomes these limitations and can be used to sample lesions adjacent to the segmental or subsegmental bronchi of the upper lobe.
REBUS-TBNA and CEBUS-TBNA diagnostic yields and adverse events
Although REBUS-TBNA and CEBUS-TBNA both have advantages, limitations, and unique indications (Table 6), comparisons between them are indirect. To evaluate the diagnostic yield and safety of REBUS-TBNA more effectively, within a clinical context, we included a control group of patients who underwent CEBUS-TBNA. To minimize confounding factors (e.g., equipment operation status, consumable batch, operator experience, gender), these patients were gender-matched and each was the next CEBUS-TBNA patient of the same operator who performed the observational patient’s REBUS-TBNA.
CEBUS-TBNA is widely accepted as an efficacious, safe technique, which plays a crucial role in the diagnosis and treatment of various benign and malignant lung diseases [27, 28]. For diagnosing and staging lung tumors, CEBUS-TBNA demonstrates high sensitivity and diagnostic yield, and low complication rates [29, 30]. The American College of Chest Physicians non-small cell lung cancer guidelines report a sensitivity of 91% for diagnostic EBUS-TBNA [24]. Several studies have reported complication rates up to 1.44% [30–34]. Substantial evidence also suggests that CEBUS-TBNA exhibits high diagnostic yield and low complication rates in diagnosing benign diseases [35, 36]. These CEBUS-TBNA findings align with the diagnostic yield of 92% and complication rate of 4% reported herein.
Concerns have been raised regarding the lower diagnostic yield and inferior safety profile of REBUS-TBNA as a non-real-time guided technique. However, our finding of non-significant differences in diagnostic yield and adverse events between it and CEBUS-TBNA indicates that they share these characteristics. This establishes REBUS-TBNA as a safe, effective diagnostic technique, particularly for lesions adjacent to the segmental or subsegmental bronchi of the upper lobe.
Puncture frequency improves diagnostic yield
Factors like lesion location, operation angle, patient tolerance, specimen quality, and operator experience can influence the number of punctures during a procedure. Our retrospective study revealed that performing more than three punctures results in a significantly higher diagnostic yield. Thus, we recommend performing at least four punctures with REBUS-TBNA, when conditions allow, and patient safety is ensured.
Limitations
This retrospective study was not without limitations. First, it was a small-sample, single-center, retrospective study. There are few related reports, and only two similar studies, to which to compare our REBUS-TBNA diagnosis rate of 84% and adverse event rate of 0. Huang et al. [16] reported diagnosis and adverse event rates of 93.75% (15/16) and 12.5% (2/16), respectively, consistent with our findings. Song et al.’s [15] diagnosis rate was 42.1% (8/19), differing slightly from our report. The reasons for these discrepancies (e.g., sample sizes, lesion sizes, lesion locations) require clarification using large, multi-center samples. Second, REBUS-TBNA lacks a mature technologic comparison with the same indications. However, comparing with CEBUS-TBNA, widely recognized for its high diagnostic rate and low adverse event incidence, we indirectly illustrated that REBUS-TBNA has similar characteristics. Third, a lack of long-term follow-up disallowed calculation of broader sensitivity. Based on these cumulative findings, continuing to explore the clinical value of REBUS-TBNA is warranted.
Conclusions
REBUS-TBNA is not only a safe and effective diagnostic technique, but it also opens up new possibilities in the field of pulmonary lesion diagnosis. Specifically, REBUS-TBNA has demonstrated unique advantages for lesions located in the segmental or subsegmental bronchi of the upper lobe. Furthermore, the value of guided sheath (GS)-TBNA in needle aspiration biopsy for peripheral pulmonary lesions (PPLs) located far from the central airway is gradually being recognized [37–39]. Looking ahead, it is foreseeable that REBUS-GS-TBNA holds great potential in the diagnosis of pulmonary lesions. We will continue to forge ahead, actively exploring and enhancing the clinical value of REBUS-TBNA, in order to bring more precise and efficient diagnostic tools to the medical community and patients alike.
Acknowledgements
We would like to thank Charlesworth (www.cwauthors.com.cn) for providing English language editing assistance.
Authors’ contributions
DM, JZ, ZZ and ZM designed the research study. JZ, QZ, BL and MG performed the research. DM, ZZ and ZM analyzed the data. DM and JZ wrote the manuscript. All authors contributed to editorial changes in the manuscript. All authors read and approved the final manuscript.
Funding
This study received partial support from the Ministry of Health Science and Technology Joint Program (2021JH2/10300102) and the Natural Science Foundation of Liaoning Province (2021-MS-039).
Data Availability
All data generated or analyzed during this study are included in this article. Further inquiries can be directed to the corresponding author.
Declarations
Ethics approval and consent to participate
This study was approved by ethics committee of General Hospital of Northern Theater Command, Shenyang, China, with an informed consent waiver (Approval number: Y(2022)125). This research was performed in accordance with the Declaration of Helsinki, Guidelines for Good Clinical Practice.
Consent for publication
Not applicable.
Competing interests
The authors declare no competing interests.
Footnotes
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Debin Ma and Junli Zhang these authors contributed equally to this work as co-first authors.
Contributor Information
Zhiyuan Zhang, Email: yuan@live.cn.
Zhuang Ma, Email: mazhuang999@yeah.net.
References
- 1.Rahman MT, Nahar NU, Ibrahim M, Islam I, Bhowmik B, Shirin M, et al. Early prediction and HRCT Evaluation of Post Covid-19 related lung fibrosis. Microbiol Insights. 2023;16:11786361231190334. doi: 10.1177/11786361231190334. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Baratella E, Bussani R, Zanconati F, Marrocchio C, Fabiola G, Braga L, et al. Radiological-pathological signatures of patients with COVID-19-related pneumomediastinum: is there a role for the sonic hedgehog and Wnt5a pathways? ERJ Open Res. 2021;7(3):00346–2021. doi: 10.1183/23120541.00346-2021. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Shai S, Patolsky F, Drori H, Scheinman EJ, Davidovits E, Davidovits G, et al. A novel, accurate, and non-invasive liquid biopsy test to measure cellular immune responses as a tool to diagnose early-stage Lung cancer: a clinical trials study. Respir Res. 2023;24(1):52. doi: 10.1186/s12931-023-02358-w. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Baratella E, Cernic S, Minelli P, Furlan G, Crimì F, Rocco S, et al. Accuracy of CT-Guided core-needle biopsy in diagnosis of thoracic lesions suspicious for primitive malignancy of the lung: a five-year retrospective analysis. Tomography. 2022;8(6):2828–38. doi: 10.3390/tomography8060236. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Yildirim E, Kirbas I, Harman A, Ozyer U, Tore HG, Aytekin C, et al. CT-guided cutting needle lung biopsy using modified coaxial technique: factors effecting risk of Complications. Eur J Radiol. 2009;70:57–60. doi: 10.1016/j.ejrad.2008.01.006. [DOI] [PubMed] [Google Scholar]
- 6.Heyer CM, Reichelt S, Peters SA, Walther JW, Müller KM, Nicolas V. Computed tomography-navigated transthoracic core biopsy of pulmonary lesions: which factors affect diagnostic yield and complication rates? Acad Radiol. 2008;15:1017–26. doi: 10.1016/j.acra.2008.02.018. [DOI] [PubMed] [Google Scholar]
- 7.Zhang Q, Zhang S, Xu X, Xu Q, Zhou J. Value of radial probe endobronchial ultrasound-guided transbronchial biopsy and computer tomography-guided transthoracic needle aspiration in the diagnosis of peripheral pulmonary lesions. Medicine. 2017;96:e7843. doi: 10.1097/MD.0000000000007843. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Folch EE, Pritchett MA, Nead MA, Bowling MR, Murgu SD, Krimsky WS, et al. Electromagnetic navigation bronchoscopy for peripheral pulmonary lesions: one-year results of the prospective, multicenter NAVIGATE study. J Thorac Oncol. 2019;14:445–58. doi: 10.1016/j.jtho.2018.11.013. [DOI] [PubMed] [Google Scholar]
- 9.Giri M, Puri A, Wang T, Huang G, Guo S. Virtual bronchoscopic navigation versus non-virtual bronchoscopic navigation assisted bronchoscopy for the diagnosis of peripheral pulmonary lesions: a systematic review and meta-analysis. Ther Adv Respir Dis. 2021;15:17534666211017048. doi: 10.1177/17534666211017048. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Gu P, Zhao YZ, Jiang LY, Zhang W, Xin Y, Han BH. Endobronchial ultrasoundguided transbronchial needle aspiration for staging of Lung cancer: a systematic review and meta-analysis. Eur J Cancer. 2009;45:1389–96. doi: 10.1016/j.ejca.2008.11.043. [DOI] [PubMed] [Google Scholar]
- 11.Adams K, Shah PL, Edmonds L, Lim E. Test performance of endobronchial ultrasound and transbronchial needle aspiration biopsy for media stinal staging in patients with Lung cancer: systematic review and meta-analysis. Thorax. 2009;64:757–62. doi: 10.1136/thx.2008.109868. [DOI] [PubMed] [Google Scholar]
- 12.Colella S, Clementsen PF, Gurioli C, Gurioli CH, Ravaglia C, Tomassetti S, et al. Endobronchial-ultrasound needle aspiration and endoscopic ultrasound-fine-needle aspiration in thoracic Diseases. Pathologica. 2016;108:59–79. [PubMed] [Google Scholar]
- 13.Lin X, Ye M, Li Y, Ren J, Lou Q, Li Y, et al. Randomized controlled trial to evaluate the utility of suction and inner-stylet of EBUS-TBNA for mediastinal and hilar lymphadenopathy. BMC Pulm Med. 2018;18(1):192. doi: 10.1186/s12890-018-0751-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Tang CL, Zhu Z, Zhong CH, Zhou ZQ, Zhou HQ, Geng RM, et al. Clinical application of endobronchial ultrasonography-guided transbronchial needle aspiration biopsy-a single center, large sample, real-world study. BMC Pulm Med. 2023;23(1):336. doi: 10.1186/s12890-023-02568-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Song N, Yang L, Wang H, Jiang L, Zhao L, Colella S, et al. Radial endobronchial ultrasound-assisted transbronchial needle aspiration for pulmonary peripheral lesions in the segmental bronchi adjacent to the central airway. Transl Lung Cancer Res. 2021;10:2625–32. doi: 10.21037/tlcr-21-490. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Huang Z, Huang H, Ning Y, Han J, Shen Y, Shi H, et al. Radial probe endobronchial ultrasound assisted conventional transbronchial needle aspiration in the diagnosis of solitary peribronchial pulmonary lesion located in the segmental bronchi. J Cancer. 2019;10:634–42. doi: 10.7150/jca.28755. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Ali MS, Trick W, Mba BI, Mohananey D, Sethi J, Musani AI. Radial endobronchial ultrasound for the diagnosis of peripheral pulmonary lesions: a systematic review and meta-analysis. Respirology. 2017;22:443–53. doi: 10.1111/resp.12980. [DOI] [PubMed] [Google Scholar]
- 18.Zarogoulidis P, Huang H, Chen W, Petridis D, Matthaios D, Hohenforst-Schmidt W, et al. Radial Endobronchial Ultrasound for Lung Cancer diagnosis: Tips and tricks. J Cancer. 2022;13(4):1307–12. doi: 10.7150/jca.67113. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Huang CT, Tsai YJ, Ho CC, Yu CJ. Radial endobronchial ultrasound-guided transbronchial biopsy for peripheral pulmonary malignancy: biopsy- or brushing-first? BMC Pulm Med. 2019;19(1):193. doi: 10.1186/s12890-019-0961-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Gupta A, Youness H, Dhillon SS, Harris K. The value of using radial endobronchial ultrasound to guide transbronchial lung cryobiopsy. J Thorac Dis. 2019;11(1):329–34. doi: 10.21037/jtd.2018.10.116. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Ali MS, Trick W, Mba BI, Mohananey D, Sethi J, Musani AI. Radial endobronchial ultrasound for the diagnosis of peripheral pulmonary lesions: a systematic review and meta-analysis. Respirology. 2017;22(3):443–53. doi: 10.1111/resp.12980. [DOI] [PubMed] [Google Scholar]
- 22.Yasufuku K, Pierre A, Darling G, de Perrot M, Waddell T, Johnston M, et al. A prospective controlled trial of endobronchial ultrasound-guided transbronchial needle aspiration compared with mediastinoscopy for mediastinal lymph node staging of Lung cancer. J Thorac Cardiovasc Surg. 2011;142:1393–400. doi: 10.1016/j.jtcvs.2011.08.037. [DOI] [PubMed] [Google Scholar]
- 23.Silvestri GA, Gonzalez AV, Jantz MA, Margolis ML, Gould MK, Tanoue LT, et al. Methods for staging non-small cell Lung cancer – diagnosis and management of Lung cancer, 3rd edn: American College of Chest Physicians evidence-based clinical practice guidelines. Chest. 2013;143:e211S–50S. doi: 10.1378/chest.12-2355. [DOI] [PubMed] [Google Scholar]
- 24.Wahidi MM, Herth F, Yasufuku K, Shepherd RW, Yarmus L, Chawla M, et al. Technical aspects of endobronchial ultrasound-guided transbronchial needle aspiration: CHEST guideline and expert panel report. Chest. 2016;149:816–35. doi: 10.1378/chest.15-1216. [DOI] [PubMed] [Google Scholar]
- 25.Aljohaney AA. Role of convex probe endobronchial ultrasound in the diagnosis and treatment of nonmalignant Diseases. Pulm Med. 2019; 6838439. [DOI] [PMC free article] [PubMed]
- 26.Shen YC, Chen CH, Tu CY. Advances in diagnostic bronchoscopy. Diagnostics. 2021;11:1984. doi: 10.3390/diagnostics11111984. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Wu J, Wu C, Zhou C, Zheng W, Li P. Recent advances in convex probe endobronchial ultrasound: a narrative review. Ann Transl Med. 2021;9:419. doi: 10.21037/atm-21-225. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Jalil BA, Yasufuku K, Khan AM. Uses, limitations, and Complications of endobronchial ultrasound. Proc (Bayl Univ Med Cent) 2015;28:325–30. doi: 10.1080/08998280.2015.11929263. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Jaliawala HA, Farooqui SM, Harris K, Abdo T, Keddissi JI, Youness HA. Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA): technical updates and pathological yield. Diagnostics. 2021;11:2331. doi: 10.3390/diagnostics11122331. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Vaidya PJ, Munavvar M, Leuppi JD, Mehta AC, Chhajed PN. Endobronchial ultrasound-guided transbronchial needle aspiration: safe as it sounds. Respirology. 2017;22:1093–101. doi: 10.1111/resp.13094. [DOI] [PubMed] [Google Scholar]
- 31.Eapen GA, Shah AM, Lei X, Jimenez CA, Morice RC, Yarmus L, et al. American College of Chest Physicians Quality Improvement Registry, Education. Complications, consequences, and practice patterns of endobronchial ultrasound-guided transbronchial needle aspiration: results of the AQuIRE registry. Chest. 2013;143:1044–53. doi: 10.1378/chest.12-0350. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Çağlayan B, Yılmaz A, Bilaçeroğlu S, Cömert SŞ, Demirci NY, Salepçi B. Complications of convex-probe endobronchial ultrasound-guided transbronchial needle aspiration: a multi-center retrospective study. Respir Care. 2016;61:243–8. doi: 10.4187/respcare.03838. [DOI] [PubMed] [Google Scholar]
- 33.Asano F, Aoe M, Ohsaki Y, Okada Y, Sasada S, Sato S, et al. Complications associated with endobronchial ultrasound-gnchial needle aspiration: a nationwide survey by the Japan Society for Respiratory Endoscopy. Respir Res. 2013;14:50. doi: 10.1186/1465-9921-14-50. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Asano F, Aoe M, Ohsaki Y, Okada Y, Sasada S, Sato S, et al. Deaths and Complications associated with respiratory endoscopy: a survey by the Japan Society for Respiratory Endoscopy in 2010. Respirology. 2012;17:478–85. doi: 10.1111/j.1440-1843.2011.02123.x. [DOI] [PubMed] [Google Scholar]
- 35.Kassirian S, Hinton SN, Iansavitchene A, Amjadi K, Chee A, Dhaliwal I, et al. Effect of needle size on diagnosis of sarcoidosis with endobronchial ultrasound-guided transbronchial needle aspiration: systematic review and meta-analysis. Ann Am Thorac Soc. 2022;19:279–90. doi: 10.1513/AnnalsATS.202103-366OC. [DOI] [PubMed] [Google Scholar]
- 36.Chandrika S, Yarmus L. Recent developments in advanced diagnostic bronchoscopy. Eur Respir Rev. 2020;29:190184. doi: 10.1183/16000617.0184-2019. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Sasada S, Izumo T, Chavez C, Tsuchida T. Blizzard sign as a specific endobronchial ultrasound image for ground glass opacity: a case report. Respiratory Med case Rep. 2014;12:19–21. doi: 10.1016/j.rmcr.2013.11.003. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Arimura K, Sekine Y, Hiroshima K, Sato A, Hasegawa M, Katsura H, et al. The efficacy of transbronchial needle aspiration with endobronchial ultrasonography using a guide sheath for peripheral pulmonary lesions suspected to be Lung cancer. Respir Investig. 2017;55(6):365–71. doi: 10.1016/j.resinv.2017.08.004. [DOI] [PubMed] [Google Scholar]
- 39.Kuno H, Sainouchi R, Simamoto T, Miyagawa-Hayashino A, Takemura Y. Diagnosis of unexposed tumours using endobronchial ultrasonography with a guide sheath and a thin transbronchial needle. Respirol Case Rep. 2021;9(3):e00713. doi: 10.1002/rcr2.713. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
All data generated or analyzed during this study are included in this article. Further inquiries can be directed to the corresponding author.