Corresponding Author

Key Words: aortic stenosis, membranous septum, permanent pacemaker implantation, transcatheter aortic valve replacement, transjugular intracardiac echocardiography
During the last decade, devices for transcatheter aortic valve replacement (TAVR) have been shown to allow for dedicated percutaneous approaches with many improvements in transcatheter heart valve (THV) delivery, making general anesthesia and endotracheal intubation unnecessary complications of the procedure. In light of further advancements in TAVR devices, procedural guidance by angiography and fluoroscopy only without any echocardiographic viewing or with just intermittent transthoracic echocardiographic assessment has become the standard approach at many centers worldwide.1, 2, 3 Dispensation with permanent echocardiographic guidance (PEG) remains controversial and may be adverse in high-risk patients, and PEG guidance mostly provided by transesophageal echocardiography (TEE) obviously seems to have several advantages over any “minimalist approach”—for example, significant reduction in the use of radio contrast,4 effective imaging to facilitate crossing the native aortic valve, help with adequate balloon and device positioning for optimal deployment of the THV,5,6 and detection of life-threatening complications at an early stage.7, 8, 9 Despite considerable advances during the last decade, major adverse events remain a concern during and after TAVR.10 With the decreasing age of TAVR candidates, minimizing potential complications of any kind remains the focus of attention. Those detectable by TEE include annulus rupture,11,12 perforation of the myocardium with subsequent pericardial hemorrhage,13 coronary ostia occlusion with subsequent myocardial ischemia,14 aortic annulus perforation or aortic dissection,13 THV malpositioning or dislodgement,15 and paravalvular leak.16
In this issue of JACC: Asia, in their original paper based on a retrospective analysis, Murakami et al17 focus on a specific and not immediately life-threatening complication: high-grade atrioventricular block caused by compression of the conductive system by the THV with subsequent need for permanent pacemaker implantation (PPMI). It turns out that guidance of TAVR using intracardiac echocardiography (ICE) from a transjugular (TJ) approach may optimize valve positioning and subsequent deployment, significantly reducing the PPMI rate. Therefore, Murakami et al17 associate ICE monitoring with a lower rate of high-grade atrioventricular block requiring fewer PPMIs. This may be considered an important and new message showing to what extent improvements in outcome can be achieved by permanent ICE guidance, which has been already reported as beneficial in TAVR in another context.18, 19, 20, 21 Although ICE guidance of TAVR is not new, for the first time, Murakami et al17 report a clinical benefit using a TJ ICE approach, which was not just shown to be feasible and safe but might also facilitate worksharing between interventional and imaging team members. As previously shown for transfemoral ICE,20 Murakami et al17 demonstrated TJ ICE to perfectly fit into the procedural workflow of TAVR.
About 20 years after the introduction of ICE for PEG during interventional procedures,22,23 costs and lack of expertise19 must be considered the most important obstacles preventing interventional cardiologists from taking full advantage of ICE monitoring during TAVR. Resterilization of ICE catheters has been allowed in some countries—for example, in Germany—and may help reduce costs. However, the direct clinical impact will be, finally, more important than any monetary costs or savings. Therefore, PEG provided by ICE including a TJ approach promises to be advantageous not only compared with “minimalist” approaches but also with TEE, which requires general anesthesia for permanent viewing.18,20 Training and a consequent team approach with equally entitled roles of interventional and imaging cardiologists have proved a recipe for benefit from ICE guidance and procedural success in general. The recent introduction of 3-dimensional ICE for the monitoring of complex interventional procedures in structural heart disease represents another promising development, which again might place special emphasis on ICE and increase its acceptance as a guiding tool in general.24 Thus, use of ICE should be considered more often in high-risk TAVR cases,19,20 particularly in patients with pre-existing conduction block. Nonetheless, randomized and prospective trials comparing the accuracy, reproducibility, and outcomes of ICE guidance vs guidance by TEE and vs pure fluoroscopy and angiography need to be performed before ICE imaging is adopted as the primary nonradiographic imaging modality for TAVR.
Funding Support and Author Disclosures
The author has reported that he has no relationships relevant to the contents of this paper to disclose.
Footnotes
The author attests they are in compliance with human studies committees and animal welfare regulations of the author’s institution and Food and Drug Administration guidelines, including patient consent where appropriate. For more information, visit the Author Center.
References
- 1.Greif M., Lange P., Nabauer M., et al. Transcutaneous aortic valve replacement with the Edwards SAPIEN XT and Medtronic CoreValve prosthesis under fluoroscopic guidance and local anaesthesia only. Heart. 2014;100:691–695. doi: 10.1136/heartjnl-2013-304918. [DOI] [PubMed] [Google Scholar]
- 2.Durand E., Borz B., Godin M., et al. Transfemoral aortic valve replacement with the Edwards SAPIEN and Edwards SAPIEN XT prosthesis using exclusively local anesthesia and fluoroscopic guidance: feasibility and 30-day outcomes. J Am Coll Cardiol Intv. 2012;5:461–464. doi: 10.1016/j.jcin.2012.01.018. [DOI] [PubMed] [Google Scholar]
- 3.Yamamoto M., Meguro K., Mouillet G., et al. Effect of local anesthetic management with conscious sedation in patients undergoing transcatheter aortic valve implantation. Am J Cardiol. 2013;111:94–99. doi: 10.1016/j.amjcard.2012.08.053. [DOI] [PubMed] [Google Scholar]
- 4.Bagur R., Rodés-Cabau J., Doyle D., et al. Usefulness of TEE as the primary imaging technique to guide transcatheter transapical and aortic valve implantation. J Am Coll Cardiol Img. 2011;4:115–124. doi: 10.1016/j.jcmg.2010.10.009. [DOI] [PubMed] [Google Scholar]
- 5.Smith L.A., Monaghan M.J. Monitoring of procedures: peri-interventional echo assessment for transcatheter aortic valve implantation. Eur Heart J Cardiovasc Imaging. 2013;14:840–850. doi: 10.1093/ehjci/jet042. [DOI] [PubMed] [Google Scholar]
- 6.Smith L.A., Dworakowski R., Bhan A., et al. Real-time three-dimensional transesophageal echocardiography adds value to transcatheter aortic valve implantation. J Am Soc Echocardiogr. 2013;26:359–369. doi: 10.1016/j.echo.2013.01.014. [DOI] [PubMed] [Google Scholar]
- 7.Walther T., Hamm C.W., Schuler G., et al. Peri-operative results and complications in 15,964 transcatheter aortic valve replacements: prospective data from the GARY registry. J Am Coll Cardiol. 2015;65:2173–2180. doi: 10.1016/j.jacc.2015.03.034. [DOI] [PubMed] [Google Scholar]
- 8.Hahn R.T., Gillam L.D., Little S.H. Echocardiographic imaging of procedural complications during self-expandable transcatheter aortic valve replacement. J Am Coll Cardiol Img. 2015;8:319–336. doi: 10.1016/j.jcmg.2015.01.001. [DOI] [PubMed] [Google Scholar]
- 9.Hahn R.T., Kodali S., Tuzcu E.M., et al. Echocardiographic imaging of procedural complications during balloon-expandable transcatheter aortic valve replacement. J Am Coll Cardiol Img. 2015;8:288–318. doi: 10.1016/j.jcmg.2014.12.013. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Van Ginkel D.J., Brouwer J., van Hemert N.D., et al. Major threats to early safety after transcatheter aortic valve implantation in a contemporary cohort of real-world patients. Neth Heart J. 2021;29:632–642. doi: 10.1007/s12471-021-01638-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Blanke P., Reinöhl J., Schlensak C., et al. Prosthesis oversizing in balloon-expandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root. Circ Cardiovasc Interv. 2012;5:540–548. doi: 10.1161/CIRCINTERVENTIONS.111.967349. [DOI] [PubMed] [Google Scholar]
- 12.Hayashida K., Bouvier E., Lefevre T., et al. Potential mechanism of annulus rupture during transcatheter aortic valve implantation. Catheter Cardiovasc Interv. 2013;82:E742–E746. doi: 10.1002/ccd.24524. [DOI] [PubMed] [Google Scholar]
- 13.Hein R., Abdel-Wahab M., Sievert H., et al. Outcome of patients after emergency conversion from transcatheter aortic valve implantation to surgery. EuroIntervention. 2013;9:446–451. doi: 10.4244/EIJV9I4A73. [DOI] [PubMed] [Google Scholar]
- 14.Ribeiro H.B., Webb J.G., Makkar R.R., et al. Predictive factors, management, and clinical outcomes of coronary obstruction following transcatheter aortic valve implantation: insights from a large multicenter registry. J Am Coll Cardiol. 2013;62:1552–1562. doi: 10.1016/j.jacc.2013.07.040. [DOI] [PubMed] [Google Scholar]
- 15.Makkar R.R., Jilaihawi H., Chakravartu T., et al. Determinants and outcome of acute transcatheter valve-in-valve therapy or embolization: a study of multiple valve implants in the U.S. PARTNER trial (Placement of Aortic Transcatheter Valve Trial With Edwards SAPIEN Transcatheter Heart Valve) J Am Coll Cardiol. 2013;62:418–430. doi: 10.1016/j.jacc.2013.04.037. [DOI] [PubMed] [Google Scholar]
- 16.Pibarot P., Hahn R.T., Weissman N.J., Monaghan M.J. Assessment of paravalvular regurgitation following TAVR: a proposal of unifying grading scheme. J Am Coll Cardiol Img. 2015;8:340–360. doi: 10.1016/j.jcmg.2015.01.008. [DOI] [PubMed] [Google Scholar]
- 17.Murakami T., Horinouchi H., Noda S., et al. Feasibility and outcome of transjugular intracardiac echocardiography-guided transcatheter aortic valve replacement. JACC: Asia. 2023;3(6):925–934. doi: 10.1016/j.jacasi.2023.07.013. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Bartel T., Edris A., Velik-Salchner C., Müller S. Intracardiac echocardiography for guidance of transcatheter aortic valve implantation under monitored sedation: a solution to a dilemma? Eur Heart J Cardiovasc Imaging. 2016;17:1–8. doi: 10.1093/ehjci/jev280. [DOI] [PubMed] [Google Scholar]
- 19.Bartel T., Müller S., Biviano A., Hahn R.T. Why is intracardiac echocardiography helpful? Benefits, costs, and how to learn. Eur Heart J. 2014;35:69–76. doi: 10.1093/eurheartj/eht411. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Bartel T., Bonaros N., Müller L., et al. Intracardiac echocardiography: a new guiding tool for transcatheter aortic valve replacement. J Am Soc Echocardiogr. 2011;24:966–975. doi: 10.1016/j.echo.2011.04.009. [DOI] [PubMed] [Google Scholar]
- 21.Müller S., Velik-Salchner C., Edlinger M., et al. Intracardiac Doppler echocardiography for monitoring of pulmonary artery pressures in high-risk patients undergoing transcatheter aortic valve replacement. J Am Soc Echocardiogr. 2016;29:83–91. doi: 10.1016/j.echo.2015.09.003. [DOI] [PubMed] [Google Scholar]
- 22.Burke M.C., Roberts M.J., Knight B.P. Integration of cardiac imaging and electrophysiology during catheter ablation procedures for atrial fibrillation. J Electrocardiol. 2006;39:S188–S192. doi: 10.1016/j.jelectrocard.2006.05.032. [DOI] [PubMed] [Google Scholar]
- 23.Bartel T., Konorza T., Arjumand J., et al. Intracardiac echocardiography is superior to conventional monitoring for guiding closure of interatrial communications. Circulation. 2003;107:795–797. doi: 10.1161/01.cir.0000057547.00909.1c. [DOI] [PubMed] [Google Scholar]
- 24.Chadderdon S.M., Eleid M.F., Thaden J.J., et al. Three-dimensional intracardiac echocardiography for tricuspid transcatheter edge-to-edge repair. Struct Heart. 2022;6(4) doi: 10.1016/j.shj.2022.100071. Published correction appears in Struct Heart. 2023;7:100161. [DOI] [PMC free article] [PubMed] [Google Scholar]