Skip to main content
The Journal of Clinical Investigation logoLink to The Journal of Clinical Investigation
. 1954;33(4):482–504. doi: 10.1172/JCI102919

MEASUREMENT OF BLOOD FLOW AND VOLUME IN THE FOREARM OF MAN; WITH NOTES ON THE THEORY OF INDICATOR-DILUTION AND ON PRODUCTION OF TURBULENCE, HEMOLYSIS, AND VASODILATATION BY INTRA-VASCULAR INJECTION 1

R Andres 1,2,2, K L Zierler 1,2, H M Anderson 1,2, W N Stainsby 1,2, G Cader 1,2, A S Ghrayyib 1,2, J L Lilienthal JR 1,2
PMCID: PMC1087263  PMID: 13152188

Full text

PDF
482

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. BINET L., BURSTEIN M. Sur les propriétés vasomotrices du sang. Présence d'une substance vasodilatatrice dans les globules rouges. C R Seances Soc Biol Fil. 1950 Jun;144(11-12):796–798. [PubMed] [Google Scholar]
  2. Barcroft H., Edholm O. G. The effect of temperature on blood flow and deep temperature in the human forearm. J Physiol. 1943 Jun 30;102(1):5–20. doi: 10.1113/jphysiol.1943.sp004009. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. CHAMBLISS J. R., DEMMING J., WELLS K., CLINE W. W., ECKSTEIN R. W. Effects of hemolyzed blood on coronary blood flow. Am J Physiol. 1950 Dec;163(3):545–553. doi: 10.1152/ajplegacy.1950.163.3.545. [DOI] [PubMed] [Google Scholar]
  4. COULTER N. A., Jr, PAPPENHEIMER J. R. Development of turbulence in flowing blood. Am J Physiol. 1949 Nov;159(2):401–408. doi: 10.1152/ajplegacy.1949.159.2.401. [DOI] [PubMed] [Google Scholar]
  5. Gibson J. G., Evans W. A. CLINICAL STUDIES OF THE BLOOD VOLUME. I. CLINICAL APPLICATION OF A METHOD EMPLOYING THE AZO DYE "EVANS BLUE" AND THE SPECTROPHOTOMETER. J Clin Invest. 1937 May;16(3):301–316. doi: 10.1172/JCI100859. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. JACKSON D. M., NUTT M. E. Intercellular plasma and its effect on absolute red cell volume determination. J Physiol. 1951 Oct 29;115(2):196–205. doi: 10.1113/jphysiol.1951.sp004664. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. LEWIS A. E. Measurement of thoracic visceral plasma volume. Am J Physiol. 1953 Jan;172(1):195–202. doi: 10.1152/ajplegacy.1952.172.1.195. [DOI] [PubMed] [Google Scholar]
  8. REYNOLDS S. R. M., LIGHT F. W., Jr, ARDRAN G. M., PRICHARD M. M. L. The qualitative nature of pulsatile flow in umbilical blood vessels, with observations on flow in the aorta. Bull Johns Hopkins Hosp. 1952 Aug;91(2):83–104. [PubMed] [Google Scholar]
  9. Stewart G. N. Researches on the Circulation Time and on the Influences which affect it. J Physiol. 1897 Nov 20;22(3):159–183. doi: 10.1113/jphysiol.1897.sp000684. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Investigation are provided here courtesy of American Society for Clinical Investigation

RESOURCES