Abstract
The absence of teeth, known as edentulism, poses considerable obstacles in prosthodontic care and greatly affects a person's well-being. Conventional complete dentures frequently lead to problems like instability and insufficient retention, especially in the lower jaw. Fortunately, the introduction of dental implants has transformed the way we approach edentulous patients, as they now offer support and enhanced retention for removable prostheses, thus revolutionizing their treatment. While a consensus exists on using two implants for retaining mandibular overdentures, the associated cost may be prohibitive for economically disadvantaged individuals. As a solution, the concept of single implant-retained mandibular overdentures has emerged, catering to individuals with limited financial resources and complete tooth loss. This review explores the efficacy and suitability of the single implant overdenture approach, along with an overview of treatment options for edentulous patients, including traditional dentures, tooth-supported overdentures, and implant-supported overdentures. The preservation of bone, improvements in functional abilities, and psychological benefits associated with overdentures are discussed. Moreover, various classifications and prosthetic options for implant overdentures, specifically for mandibular cases, are presented. This literature review aims to provide a comprehensive understanding of possible treatment options and focus on the single implant-retained mandibular overdenture approach and its implications in prosthodontic rehabilitation for edentulous patients.
Keywords: prosthodontics, overdenture, complete denture, single implant, dental implant
Introduction and background
Edentulism poses significant challenges in prosthodontic management and can have a profound impact on an individual's quality of life. Although traditional complete dentures have long been used to treat edentulous patients, they frequently present challenges such as instability and poor retention, causing discomfort and anxiety, especially with mandibular dentures [1].
The advent of dental implants has revolutionized the management of edentulous patients by providing support and retention for removable prostheses. However, determining the optimal number of implants for retaining mandibular overdentures is still a topic of ongoing research. There is a consensus that suggests that a standard approach for the edentulous mandible is an implant-retained overdenture with two implants placed in the anterior mandible. Nonetheless, the cost associated with this treatment may be prohibitive for many economically disadvantaged edentulous individuals, particularly in developing countries [2].
In light of this challenge, the concept of a single implant-retained mandibular overdenture has arisen as a viable treatment alternative, specifically for edentulous individuals with restricted financial means or those who are medically compromised and unable to endure invasive surgical procedures to install multiple implants that may necessitate bone grafting [3]. While the single implant overdenture approach may offer economic advantages, it necessitates comprehensive evaluation and investigation to determine its efficacy and suitability. This literature review aims to provide a comprehensive understanding of potential treatment options, with a specific focus on the single implant-retained mandibular overdenture approach and its implications in prosthodontic rehabilitation for edentulous patients.
Review
Treatment options for edentulous patients
Edentulous individuals have traditionally been treated with complete dentures, which allow them to participate in activities such as speech and eating while also preserving their facial aesthetics. This treatment involves placing a full set of prosthetic teeth that are held in place by the gums and underlying bone to replace all missing teeth. However, complete dentures can be unstable, especially in the mandibular jaw, due to poor retention. This lack of stability can be caused by factors such as changes in the bone structure, reduced muscle tone and saliva production, the absence of natural tooth roots for stability and support, and reliance on physical adhesion with the oral mucosa, which is less strong compared to other retention methods. This has led to criticism of this treatment modality and the recognition of the need for alternative options [4]. Furthermore, rather than preserving the bone, incorrectly planned complete dentures accelerate bone resorption. This may be attributed to the concentration of chewing forces on specific areas of the bone, primarily the outer layer, rather than evenly distributing them throughout the bone. As a result, there is a loss of bone volume and reduced blood flow [5]. These issues, including problems with prosthesis retention, stability, and comfort, can significantly impact functional abilities such as speech, aesthetics, and chewing. Dental implants have revolutionized the treatment options for completely edentulous patients, providing solutions through either fixed [6-8] or removable implant-supported prostheses [9-14]. Even in cases where patients have systemic conditions [15, 16] or require bone grafting prior to implant placement, dental implants have been shown to yield effective outcomes [17-22].
Compared to conventional complete dentures, overdentures have demonstrated improvements in biting force, chewing efficiency, and speech clarity. Moreover, they promote the preservation of the alveolar ridge and offer superior support and retention for the denture [23]. The preservation of the proprioceptive system, which relies on periodontal ligaments, and the psychological acceptance of overdentures further enhance their viability as a valuable treatment option for completely edentulous patients [24]. By distributing masticatory forces more evenly across the roots and denture-supporting tissues, overdentures minimize the impact on these structures, resulting in less alveolar bone loss compared to conventional complete dentures [24].
Overdentures
An overdenture refers to a removable prosthesis that covers natural teeth, tooth roots, and/or dental implants, serving as a complete or partial denture. Various terms, such as overlay dentures, telescoped dentures, tooth-supported dentures, hybrid prostheses, crown and sleeve prostheses, and superimposing dentures, are used to describe this treatment technique [25]. The support provided is a crucial factor, leading to the classification of overdentures into two types: implant-supported overdentures and tooth-supported overdentures. Overdenture abutments can be derived from teeth that are unable to support a fixed or removable partial denture. By reducing these teeth to achieve a favorable crown-root ratio, utilizing the splinting action of the overdenture, and establishing a favorable occlusion spread over a larger region, the strength and support of these teeth can be maintained for a certain period of time [25]. Preserving the remaining teeth, even those with a poor prognosis helps reduce alveolar bone loss and improves denture stability, particularly in the mandible, where mandibular denture stability is commonly problematic [26].
The ability of the mandible to collapse freely into the intercuspal position is attributed to periodontal receptors. In contrast to fully edentulous patients, the proprioceptive nerve terminals in the periodontal ligament transmit sensory information to the neuromuscular system, aiding in the establishment of centric jaw relation for overdentures [23]. The vertical walls of the remaining teeth contribute extra support to the overdenture, and the extent of tooth preparation directly influences the stability it provides. Furthermore, overdenture abutments offer additional denture support. Compared to conventional full dentures, tooth-supported dentures provide support to the overdenture and establish a defined vertical stop for the denture base, resulting in reduced stress on soft tissues and fewer post-insertion complications [26]. The psychological benefits of denture anchoring also contribute to increased patient confidence in social situations, as the presence of retained roots provides a sense of security [26].
Clinical studies conducted on overdenture patients have shown an increased incidence of caries around the abutment teeth. This is attributed to the coverage of teeth by the overdenture, which leads to the absence of a salivary film and the buffering action of saliva around the abutments, thereby increasing the risk of acid attack and susceptibility to caries. Various approaches have been used to manage caries, including protecting the tooth with a metal casting or using topical fluoride. Fluoride gel has been demonstrated as an effective method for preventing cavities on retained overdenture abutments. It should be noted that covering the gum edges of abutment teeth with an overdenture has the potential to cause periodontal disease, leading to gingival hemorrhage and visible inflammation around the abutment teeth. To minimize these issues, meticulous plaque control is recommended [23]. Another drawback is the presence of significant labial undercuts at the abutment teeth, which can interfere with denture insertion. This often requires the removal of excessive acrylic resin from the inner surface of the denture, weakening the denture base and making it more susceptible to fracture [24]. In addition, an overdenture may be bulkier than a full denture, resulting in speech difficulties and compromised esthetics. Furthermore, the significant occlusal pressure exerted on the overdenture can lead to denture base fracture at the abutment area due to wear-induced thinning between the denture base and the supporting natural teeth. A well-designed occlusion can reduce the risk of fracture.
Implant-supported overdentures
Implant-supported overdentures have emerged as a solution to address common concerns such as tooth decay and periodontal disease. Compared to relying on endodontic, periodontal, and prosthodontic procedures to preserve teeth as overdenture abutments, the use of implants has proven to be more cost-efficient and predictable [27]. The placement of dental implants has evolved to become a less time-consuming, aesthetically appealing, and minimally invasive procedure for the restoration of missing dentition [28].
One of the advantages of implant-supported overdentures is their ability to preserve the surrounding bone. In the case of anterior mandibular bone beneath an implant overdenture, it has been observed that bone resorption may reach up to 0.5 mm over a five-year period, with long-term resorption remaining relatively constant at 0.1 mm per year. This level of bone resorption is significantly lower than what is typically observed in edentulous ridges and is comparable to the condition seen with overdentures supported by natural teeth. Consequently, dental implants help protect the bone and prevent further loss [27].
Prosthetic options for implant overdentures
Various classifications have been proposed to categorize implant placement, whether in the form of fixed or removable prostheses. Misch introduced a classification system consisting of five prosthetic solutions for patients with implant-supported prostheses. The first three solutions involve fixed prostheses, which can be either cemented or screw-retained and can replace partial or complete dentitions. The choice of solution depends on the number of structures being replaced, both in terms of hard and soft tissues, as well as the aesthetic requirements of the prosthesis. The remaining two solutions are detachable overdenture prostheses, which differ in terms of implant support, with fully removable overdentures being considered an acceptable treatment option [29].
Furthermore, Misch proposed five well-defined treatment alternatives specifically for implant-supported mandibular overdentures in completely edentulous patients. The first treatment option (OD1) involves placing two implants in the canine regions without connecting them through a superstructure. The most commonly used connection design in this case is an O-ring configuration. The second treatment option (OD2) involves placing implants in the canine regions and splinting them together with a superstructure without a distal cantilever. This results in lower loading forces on the two anterior implants when they are splinted with a bar, as compared to individual implants. In the third treatment option (OD3), three root-form implants are inserted and joined with a superstructure bar, again without a distal cantilever. The additional implant helps reduce the flexure of the superstructure. The fourth treatment option (OD4) involves placing four implants in the canines and first premolar regions, providing sufficient support to include a distal cantilever of up to 10 mm on each side if stress factors are low. The fifth treatment option (OD5) consists of placing five implants, with an additional implant at the midline, and cantilevering the superstructure distally up to a maximum of 2.5 times the anterior-posterior spread [29].
Implant overdentures can be further classified based on the type of support they rely on, namely predominantly mucosa-supported, implant-mucosa-supported, and implant-supported overdentures. The term "mucosa-supported" is used to describe overdentures retained by studs or magnetic attachments, typically involving two implants. On the other hand, "implant-mucosa-supported" refers to overdentures retained by a resilient bar attachment, usually involving four implants [30]. When four or more implants are used to provide complete support, the prosthesis is considered entirely implant-supported, with no contribution from the surrounding mucosa. In certain cases, a distally expanded cantilever bar has been suggested to enhance the retention of the distal component. However, this may lead to increased stress on the implants during mastication [31].
Another study defined implant-retained overdentures in terms of being entirely implant-supported, predominantly implant-supported, implant-retained, or implant-retained and soft tissue-supported. The term "implant-supported" was primarily used to describe overdentures held in place by multiple bar segments or more than two ball attachments without a cantilever extension, as limited movement is expected in both cases due to the absence of a rotational axis [32-34]. In the case of an implant-mucosa-supported prosthesis, load sharing occurs between the implants and the distal extension mucosa. This often involves the use of fewer implants, typically two interforaminal implants, and allows for movement of the prosthesis under functional loads. The attachment's durability, such as with stud attachments, and/or the presence of a spacer layer between the superstructure and the attachment, as in bar or resilient telescopic attachments, enable movement and/or flexion of the distal extension of the denture base, provided that there is intimate contact between the denture base and the load-bearing mucosa. Consequently, the degree of permitted movement and the percentage of load shared between the implant and the mucosa may vary. Implant overdentures offer several advantages over completely implant-supported fixed dentures, such as requiring fewer implants, resulting in lower costs for the patient [35, 36]. Additionally, overdentures are typically easier to repair compared to fixed restorations, provide better esthetics, and offer soft tissue support for the facial appearance of many edentulous patients [37]. Moreover, the ability to remove overdentures at night reduces the impact of para-functional habits and associated strains on the implant support system [38]. Furthermore, the use of robust attachments in overdentures helps minimize stress on the implants and allows for stress release [38]. Implant-supported overdentures also offer the advantage of reducing soft tissue coverage by reducing prosthesis flanges and palatal coverage, leading to increased patient satisfaction and improved taste sensation [39]. According to the McGill consensus statement in 2002, the initial treatment option for a completely edentulous mandible is the placement of two implants to support an overdenture, as this option provides superior stability and speech compared to conventional full dentures [40].
However, there are certain drawbacks associated with mandibular implant-retained overdentures. One significant concern is related to the psychological impact on patients, as the removable nature of the prosthesis may affect their perception and acceptance compared to fixed implant-supported prostheses [29]. Another issue is the requirement of a minimum interarch space of 10 mm to accommodate the denture teeth, acrylic resin foundation, and attachment retainers for implant-retained overdentures [41, 42]. Long-term maintenance is also a notable challenge for mandibular overdenture wearers, as attachments like O-rings and clips may need frequent replacement due to wear and tear [43-45]. Additionally, the posterior ridge in implant-supported overdentures tends to resorb faster than the anterior bone, necessitating regular relining to maintain a proper fit [46]. Food impaction is another concern with mandibular overdentures, as the flanges do not reach the bottom of the mouth in the rest position, potentially leading to discomfort [42].
Mandibular single implant-retained overdentures
According to previous studies, there were no significant changes in patient satisfaction or clinical or radiographic conditions when comparing the use of two or four implants for overdenture treatment [2]. However, the financial cost associated with therapy is an important consideration in treatment selection; as the number of implants increases, so does the cost [3]. Consequently, there is a need for a more cost-effective treatment alternative, such as an overdenture retained by a single implant. Single implant-retained overdentures have gained popularity in recent years due to their lower costs, minimal tissue stress, potential surgical advantages, reduced associated morbidity, and decreased post-surgical maintenance [47-50].
Multiple studies have demonstrated the effectiveness of single implant-retained overdentures, showing no significant differences in survivorship between a single implant and two implants when used with a full mandibular overdenture [49]. For elderly edentulous individuals seeking improved oral health-related quality of life (OHRQoL) and chewing abilities, a single implant placed in the midline of the mandibular arch is recommended as a viable treatment option [51]. Additionally, individuals experiencing pain and functional issues with their traditional mandibular dentures can benefit from this treatment [52]. Furthermore, single implant-retained overdentures have shown comparable patient satisfaction to two implant-retained overdentures while offering the advantages of reduced cost and shorter treatment time [49].
Recent research has indicated that the lateral stresses on the abutments of mandibular overdentures held by one or two implants are similar [53]. Clinicians have suggested that as the number of implants increases, the maximum strain value in the peri-implant bone decreases, and the strain distribution becomes more evenly distributed. This is based on the concept that adding additional anchoring and support implants reduces the force carried by each implant, resulting in less strain on the bone. However, under different loading conditions, the strain value in peri-implant bone has been observed to increase with the number of implants [54]. In contrast, single implants exhibit minimal strain in the peri-implant bone, low stress in the abutments, and no detrimental strain concentration in the bone surrounding the lone implant.
Comparing overdentures retained by single and two implants, it has been found that under vertical load, single implant overdentures rotate over the implant from side to side without a significant increase in peri-implant bone strain. In contrast, two implant-retained overdentures show more apparent rotation around the fulcrum line passing through the two implants, and the maximum equivalent stress in the abutments is higher [54, 55].
The use of a single implant with a ball attachment has been clinically proven to be a satisfactory treatment for retaining mandibular overdentures, as it increases denture stability, oral health-related quality of life, and masticatory function [56, 57]. Large ball attachment systems, such as titanium nitride-coated patrices and plastic matrices, have been found to provide higher retentive forces for mandibular single-implant overdentures, as well as favorable wear behavior and clinical performance [58, 59]. When comparing the Locator attachment to ball attachment systems for restoring single implant-retained mandibular overdentures, the Locator attachment has been found to be superior, as other attachment systems are prone to wear and loss of retention, leading to significant maintenance costs [59, 60].
Mandibular single-implant overdentures, when used with an early loading strategy and implants of various diameters and attachment methods, have been shown to be a viable treatment option for older edentulous individuals [58]. However, there are risks associated with inserting a single implant in the midline of a damaged atrophic mandible, such as mandibular fracture and proximity to the lingual artery [61]. One of the common complications with single implant-retained overdentures is denture fracture and the need for more prosthetic maintenance. The concentration of stresses within the denture bases over the implants may explain why there is a relatively higher incidence of denture fractures in single-implant overdentures. Greater fracture risk may also be associated with the tendency of the denture to fulcrum over a single implant when the mucosa atop the remaining ridge compresses with denture wear or the ridge resorbs, necessitating ongoing monitoring over time. However, several trials have shown no substantial difference in the frequency of denture base fractures between overdentures retained by a single implant and those retained by two implants [62]. To reduce the risk of denture breakage, a metal-strengthened single implant mandibular overdenture with a locator attachment as a retention device has been suggested. The metal-reinforced structure within the acrylic resin foundation provides increased stiffness, preventing denture fracture [63].
There is a possibility that the forces exerted on an overdenture supported by a single implant are greater than those exerted on a multiple implant-retained/supported overdenture, which may increase the risk of loss of osseointegration [1]. Biomechanical studies have shown that single-implant overdentures exhibit similar biomechanical characteristics to two-implant overdentures in terms of lateral forces on the abutment and denture base movements under functional molar loads [53]. The success of single implant-retained overdentures is also influenced by patient selection. Since a single implant cannot provide significant support and retention for the entire arch, the stability of the overdenture relies heavily on the support provided by the alveolar ridge tissue [64].
When planning the treatment for a single implant-retained full denture, it is crucial to emphasize that the prosthesis should be tissue-borne. The stability and retention of the denture are achieved by contacting key stress-bearing sites, such as the residual ridge and the buccal shelf. Engaging the retromylohyoid area can improve the lateral stability of the mandibular prosthesis, and the use of an attachment in a single implant-supported overdenture enhances retention [64]. In cases with significantly atrophied ridges, the absence of resistance to lateral and rotational stresses can compromise stability and chewing efficiency. Therefore, stud attachments such as the Locator may provide better stability and retentive force compared to magnetic attachments [59].
In individuals with inadequate alveolar tissue support, the quality of overdenture occlusion, particularly balanced occlusion, is crucial. To avoid harmful lateral and rotational stresses during function, occlusal contacts should be balanced in all directions [65, 66]. A reduced dental arch overdenture is proposed based on the theory that reducing the number of posterior teeth in an implant-supported overdenture can prevent crestal bone loss around the implants during the healing phase [65, 66].
The utilization of single symphyseal implants to rehabilitate edentulous mandibles was first reported by Naert et al. in 1991 [67]. In the same year, Cordioli et al. conducted a five-year prospective analysis of 21 senior patients treated with single implant-retained overdentures, reporting a 100% success rate with low yearly radiographic bone loss [68]. This treatment technique offers a successful, cost-effective, and practical option for patients with mandibular ridge resorption, for whom wearing traditional full dentures is challenging. Several investigations have demonstrated the success and clinical viability of single implant-retained overdentures [68]. However, these studies have shown variations in procedures and have been associated with various difficulties. Systematic reviews conducted by Srinivasan et al. and Batista et al. assessed the clinical viability of single implants with overdentures and found that their survival rates were comparable to those of two implants with overdentures [69,70]. Nogueira et al. conducted a comprehensive evaluation and reported that single implant-retained overdentures improved patient satisfaction compared to standard full denture treatment [71]. Several studies demonstrated that single implant-retained overdentures outperformed traditional two implant-retained overdentures in terms of implant success and marginal bone loss [72-79].
The studies reported the use of implants with an average length of 10 mm, ranging from 7 mm to 15 mm. The sizes of the implants used varied from 3.75 mm to 8 mm throughout the trials. Alsaheeba et al. observed a 100% success rate in implants with diameters of 4 mm and 8 mm, compared to implants with a diameter of 2.75 mm, which had a 75% survival rate [75]. Various surface treatments were employed, including air abrasion, acid etching, sandblasting, and acid etching, with studies reporting a 100% implant survival rate [78, 79]. According to Liddelow et al., oxidized implants had a 100% survival rate, while all machined implants used in the study failed [74, 75]. The total failure rate per 100 implant years was 6.03, and the estimated five- and 10-year survival rates were 91.93% and 83.95%, respectively [76].
For immediate loading, implants with an insertion torque of 45 Ncm were considered suitable in some reports, and implants with an implant stability quotient (ISQ) of 60 were deemed appropriate for immediate loading [74-78]. Immediate loading was used in five experiments, while early loading was performed in three trials at six weeks postoperatively. The remaining trials employed a standard (delayed) loading strategy with durations ranging from two to four months [68, 73, 79, 80-87]. The survival rates varied depending on the loading protocol.
Nogueira et al. reported a survival rate of 100% for immediate loading and early loading protocols, while delayed loading had a survival rate of 96.6% [71]. Alsaheb et al. reported a 100% survival rate for immediate loading and early loading and a 92.8% survival rate for delayed loading [75]. The success rates reported in the studies varied between 88% and 100%, with the majority of studies reporting success rates above 90% [68-87].
In summary, single implant-retained overdentures can be a successful treatment option for patients with mandibular ridge resorption who have difficulty wearing traditional full dentures. The success rates of single implant-retained overdentures are comparable to those of two implant-retained overdentures. Factors such as patient selection, implant length and diameter, surface treatment, loading protocol, and occlusal considerations play important roles in the success and stability of single implant-retained overdentures. It is important to consult with a qualified dental professional or implantologist to determine the best treatment plan for your specific situation. They can evaluate your oral health, bone structure, and other factors to provide personalized recommendations and discuss the potential risks and benefits of single implant-retained overdentures. Table 1 summarizes the differences between a conventional complete denture, a single implant overdenture, and a multiple implant overdenture.
Table 1. The differences between a conventional complete denture, a single implant overdenture, and a multiple implant overdenture.
Factors | Conventional complete denture | Single implant-retained overdenture | Multiple implant-supported overdenture |
Retention | Dependent on physical means of retention and can use adhesives | Improved retention with the use of an attachment screwed to the implant | Enhanced retention due to multiple attachments used with implants |
Number of implants required | None | One implant (placed at midline) | Two or more implants |
Patient satisfaction | Varies depending on individual experience | Generally higher satisfaction due to improved stability | High satisfaction due to improved stability and functionality |
Biting force | Reduced biting force compared to natural dentition | Improved biting force compared to conventional dentures | Enhanced biting force, closer to the natural dentition in cases with four or more implants |
Maintenance | Regular cleaning of dentures and oral hygiene | Regular cleaning of dentures and oral hygiene, periodic implant and attachment maintenance | Regular cleaning of dentures and oral hygiene, periodic implant and attachment maintenance |
Time needed for construction | It typically requires fewer visits and shorter construction time than implant-supported options. | Requires multiple visits and longer construction time compared to conventional dentures | Requires multiple visits and longer construction time compared to conventional dentures |
Cost | Lower cost compared to implant-supported options | Moderate cost, considering the cost of the implant and denture | Higher cost due to multiple implants and dentures |
Attachments used in overdentures
A retainer comprises a metal receptacle and a closely fitting part, with the former (the female matrix component) typically housed within the natural or expanded contours of the abutment tooth crown and the latter (the male patrix component) attached to a pontic or denture framework [14]. Attachments offer several advantages, including enhancing the retention of tooth and implant-supported overdentures and providing both vertical and horizontal stability, thereby increasing their longevity [88]. The intermittent contact of a resilient attachment may also stimulate the underlying tissues and help resolve abutment alignment issues [88].
However, it has been shown that the incorporation of certain types of attachments in the prosthesis can impose strains on the supporting components [89]. Several factors need to be considered when deciding whether to splint or unsplint implants using attachments. These factors include the anatomical situation of the mandible, desired level of retention, ability to maintain hygiene, interarch distance, parallelism of the implants, and cost considerations [90-92].
Treatment planning and selection of overdenture attachments
Amount of Retention Needed
The retentive properties of attachments are influenced by various factors, such as maximal retentive force, range of retention, retention energy, and exhaustion behavior [93]. It is, therefore, crucial to comprehend the retentive and stabilizing qualities of attachments under different dislodging patterns. The release time is a significant factor when evaluating attachment retentive characteristics; attachments with slower release times exhibit lower retentiveness. For instance, bar attachments have a quicker release time compared to magnet attachments, rendering them more retentive [93]. The design of overdenture attachments and the forces involved in dislodgment can significantly affect the stress and strain around implants [94]. Stronger attachment retention leads to higher transmitted stresses to implants. Hence, understanding the retentive and stabilizing qualities of attachments is crucial in selecting the appropriate overdenture attachment type. In a study comparing magnetic and stud overdenture attachments, stud attachments demonstrated superior retentive and stabilizing forces compared to magnetic attachments [95].
The retentive force of Locator, ball, and magnetic attachments in mandibular implant-retained overdentures is provided by mechanical interlocking, frictional contact, or magnetic forces of attraction between the patrix and matrix components. In terms of retention, magnet attachments have shown the highest value, followed by ball and socket attachments [96-99]. It is widely accepted that bar and clip combinations offer greater retention values compared to ball or magnetic attachments [95]. Telescopic retainers have also been proven to be beneficial in implant-retained prostheses due to the frictional fit between the crown and sleeve, which ensures good retention [100]. However, it has been observed that telescopic crowns may lose retention over time due to changes in surface characteristics and metal abrasion [101].
Recently, a combination of a main screw-held framework connected to the implants and a secondary detachable superstructure with parallel friction pins and swivel latch attachments has been used to enhance retention [88]. When analyzing retention and stability in single implant overdenture scenarios, only Locator and ball attachments were found to provide adequate vertical retention. Furthermore, when comparing three widely spaced implants to three narrowly spaced implants, O-ring attachments showed reduced resistance to dislodgment, while extracoronal resilient attachment (ERA), Locator, and ball attachments exhibited greater resistance to dislodgment, indicating that widely spaced implants result in greater resistance to dislodgment for these attachments. However, when considering posterior dislodging pressures, only ball attachments offered sufficient resistance [56]. The horizontal stability of an overdenture prosthesis can be affected by the robustness of the attachment system. In comparison, Locator and ball attachments demonstrated greater stability than ERA and O-ring attachments, allowing for more flexibility in the matrix-patrix interaction and rotational movements [102].
The role of Locators in ensuring proper retention and correct seating of implant-supported overdentures is crucial. The connection of the Locator includes a skirt that wraps around the denture components, facilitating the precise alignment of the permanent mating component on the implant. The self-aligning functionality of the Locator acts as a guide plane for single implant-detachable overdentures [103].
Maxillomandibular Relationship and Interarch Space
Sufficient vertical and buccolingual space is required for the placement of attachments [104]. It is essential to encase attachments in an appropriate layer of acrylic to prevent the weakening of the denture [105]. Resilient attachments often require a significant interarch space and may contribute to posterior mandibular resorption due to vertical denture movement. On the other hand, non-resilient stud attachments allow for mobility, while rigid attachments are utilized when interocclusal space is limited [106].
In terms of interarch distance requirements, reports indicate that bar attachments necessitate a minimum distance of 13 mm, whereas Locator attachments require 8.5 mm. This discrepancy is primarily attributed to the fact that the bar attachment obtains retention either directly from the bar through a clip or stud attachments attached to the body of the bar. In contrast, the male half of the Locator attachment achieves retention by engaging the female component attached to the implant, and this internal retention feature has a modest profile. The design of the Locator attachment benefits from a low height requirement (3.7 mm) and a larger cross-section to ensure strength. Additionally, the shorter height of this attachment is advantageous in situations where interocclusal height is limited [107, 108].
Inter-implant Distance and Parallelism
The parallelism of implants is considered a critical factor in selecting the most suitable overdenture attachment type [92]. Optimal retention can be achieved when all implants are placed as parallel to each other as possible [109]. Excessive divergence between implants can lead to increased rates of wear. There are five types of retainers with stud attachments positioned at different angles to the retaining dowels, ranging from 0 to 20 degrees. The male component of the attachment features a hemispherical head that allows for ball and socket rotation and includes a pressure release groove to facilitate denture fitting [110]. The Locator attachment can also accommodate divergent implants up to 20 degrees. Various options for abutment heights, angulation correction, and retention levels are available to assist clinicians and laboratory technicians in creating the most suitable overdenture restoration for each patient [111].
Cost-Effectiveness
Precision attachments are considered to be more precise than semi-precision attachments and offer advantages such as reduced wear on the abutment and the availability of standard parts that can be easily inserted and maintained. In contrast, semi-precision attachments are more cost-effective [112, 113].
Compared to bar and clip-type implant overdentures, the use of stud attachments is a simpler and more cost-effective procedure. O-ring or ball attachments are particularly popular and widely available for implant overdentures using various implant systems due to their affordability. Solitary ball attachments are reported to be less expensive, less technique-dependent, and easier to clean than bar attachments [114].
One specific type of attachment suitable for Locator abutment platforms is the Go-Direct Prosthetic System (GPS) attachment. The GPS attachment is a low-profile cap attachment that provides rotational and vertical stress-breaking capabilities. It differs from the Locator attachment in that it does not require a specific tool for component insertion and is also less expensive [115].
Maintenance and Oral Hygiene
Stud attachments offer a hygienic advantage by minimizing conflicts between vestibular flanges apical to the abutment, exposing the bulge, and creating a more sanitary environment [105]. Additionally, telescopic overdentures are relatively easy to maintain, similar to ball attachments, as they lack difficult-to-access areas for maintenance. Moreover, telescopic overdentures have the added benefit of experiencing fewer technical issues compared to ball attachments [116].
Patients with bar attachments who have poor oral hygiene are more prone to developing mucosal hyperplasia beneath the bar and experiencing inflammation of the soft tissue surrounding the implants. Therefore, patients with inadequate oral hygiene practices are not suitable candidates for bar attachments unless they are committed to a suitable oral hygiene routine. However, in cases where a rigid prosthesis is necessary but hygiene constraints prevent the use of a fixed, detachable prosthesis, the use of a milled bar with spark erosion technology is recommended. This design offers improved hygiene procedures facilitated by the removable superstructure and enhanced facial and dental esthetics achieved through the use of a dental flange [117].
Patient Satisfaction
Patient satisfaction with overdentures is influenced by various factors, including patient preferences, chewing comfort, phonetics, esthetics, implant retention, the fit of prosthetic components and attachments, and denture precision [118]. A prospective crossover clinical study investigated patient satisfaction and its correlation with attachment retention, revealing that patients preferred attachments with higher retention, and an effective retentive force typically ranged from 8 N to 10 N [119].
Stud attachments offer the advantages of improved esthetics and patient comfort, especially for individuals who cannot tolerate palatal coverage, which can trigger the gag reflex. Ball attachments often receive higher patient satisfaction ratings and are associated with fewer soft-tissue or mechanical issues compared to bar and magnet attachments [120, 121]. Magnet attachments have been found to exhibit inferior chewing efficiency compared to ball attachments due to their weaker stability during functional activities [122, 123].
Prosthetic maintenance and complications have a significant impact on patient satisfaction. In comparisons of different overdenture attachments, magnet attachments were found to have the highest frequency of prosthetic maintenance and issues related to wear and corrosion, leading to reduced patient contentment [124]. Other common maintenance needs include clip loosening in bar attachments and matrix loosening in ball attachments. There have been debates regarding whether bar or ball attachments require more maintenance, with some studies reporting higher prosthetic care and problems with ball attachments [125], while others found that bar attachments required more maintenance [126]. Additionally, replacing clips or repairing overdentures in bar attachments was often more time-consuming than in ball attachments. The use of newly designed elliptical gold matrices in ball attachments, featuring broad wings to prevent separation from the denture base, has contributed to a reduction in complications and maintenance requirements.
Both Locator and magnet attachments have demonstrated the ability to significantly enhance patient satisfaction and masticatory efficiency in single implant-retained overdentures [127]. The Locator attachment outperformed the magnet attachment in terms of perceived chewing ability, although no significant difference was observed in objectively evaluated masticatory efficiency between the two types of attachments. Moreover, the installation of both attachment types resulted in substantial improvements in overall happiness, comfort, speech, chewing ability, and retention for patients. However, it should be noted that Locator attachment systems have similar prosthodontic maintenance requirements as other attachment systems, and while most prosthesis-related issues are easily repairable, patient dissatisfaction may arise due to the associated costs of upkeep [115].
Status of the Antagonistic Jaw
According to a consensus statement from McGill University, the choice of implant placement for implant-supported overdentures requires consideration of the opposing arch [104]. In cases where a maxillary full denture opposes the overdenture, stud attachments, rather than bar attachments, are preferred to avoid excessive forces that could destabilize the maxillary denture [128].
The Locator Attachment System, introduced in 2000 by Zest Anchors, consists of a self-aligning double-retention cylinder with inner and outer retention surfaces. The attachment includes a male component, which is an implant screw-metallic abutment, and a female component, which is a metallic cap coated with nylon of various colors indicating different retention capacities and attached to the denture [129]. The nylon attachments come in different varieties, with internal and external retention for well-positioned implants (transparent, pink, and blue) and exterior retention for non-parallel implants (green, orange, and red) [129]. The Locator attachments can accommodate divergent implants and rectify parallelism [129].
Locator attachments are suitable for complete or partial dentures supported by endosseous implants or natural tooth roots in the mandible or maxilla [130]. The choice of Locator attachments depends on their location, with mandibular placement being simpler than maxillary placement [131]. These attachments require minimal interarch space, with a recommended minimum of 8.5 mm of vertical space and 9 mm of horizontal space for implant-supported overdentures [132]. Locator attachments are particularly useful when there is insufficient space for ball attachments and can address various prosthesis-related problems, such as over-contoured prostheses, excessive occlusal vertical dimension, fractured teeth adjacent to the attachments, attachment separation from the denture, prosthesis fracture, and patient dissatisfaction [132].
One limitation of Locator attachments is their inability to provide completely rigid connections, as they allow for rotational dislodgement [131]. However, the swiveling capacity of the denture cap over the male component accommodates natural occlusion movements and the pliancy of the supporting soft tissue, ensuring a secure fit for the overdenture during chewing [129]. The rounded and cylindrical nature of the Locator attachment provides a strong connection, transferring forces and movements directly to the implant [131]. Locator attachments are not suitable for free-end saddle situations and can also be used in tooth-supported prostheses [133].
Implants with a minimum diameter of 3.3 mm are recommended for Locator attachments, and implant centers should be spaced at least 6.5 mm apart to accommodate the 5.5 mm broad metal housings [134]. Proper positioning of the Locator connection in a gingival thickness of less than 4 mm is essential to minimize excessive stresses on the implant [134]. The primary advantage of Locator attachments is their ability to adjust retentive pressures using color-coded nylon housings, and their self-aligning feature facilitates easy and quick restoration implantation [135-137].
While both Locator and ball attachments have shown comparable results in some studies, the use of Locator attachments has been associated with soft tissue discomfort and peri-mucositis in some patients, which can be resolved through rebasing or relining of the prostheses [136]. In terms of prosthodontic problems and maintenance of oral function, the Locator system has been found to produce better clinical outcomes compared to ball and bar attachments in totally edentulous individuals [138]. However, Locator attachment systems require more maintenance due to frequent matrix activation and aftercare [138].
The use of Locator attachments for the immediate loading of two implants to support a mandibular overdenture has been found to be a suitable therapeutic strategy, with marginal bone level changes similar to those observed with delayed loading approaches. In vitro investigations have shown that the retentive properties of Locator attachments diminish after repeated pulls, but they still retain significant retention for over 110,000 cycles [137].
One notable drawback of Locator attachments is the time-consuming laboratory procedure and higher cost compared to other attachment systems. Additionally, Locator attachments do not provide splinting [139-141].
Conclusions
The concept of a single implant-retained mandibular overdenture has emerged as a promising and cost-effective treatment option for completely edentulous individuals with limited financial resources and those who are medically compromised. It addresses the issues of instability and inadequate retention commonly experienced with traditional complete dentures, particularly in the lower jaw. By utilizing a single implant to support a removable prosthesis, this approach significantly improves stability, retention, and chewing efficiency, offering functional and esthetic benefits. However, careful evaluation and investigation are necessary to determine the suitability of this approach for each case, considering factors such as bone quality, occlusion, and patient expectations.
Despite the economic advantages of the single implant overdenture approach, further research is required to assess its long-term success rates, patient satisfaction, and impact on oral health-related quality of life.
The authors have declared that no competing interests exist.
Author Contributions
Concept and design: Ahmed Yaseen Alqutaibi, Dina Elawady, Ihab Ismail Mahmoud , Maya Ali Adam
Acquisition, analysis, or interpretation of data: Ahmed Yaseen Alqutaibi, Dina Elawady, Ihab Ismail Mahmoud , Ahmed Atef Shon , Maya Ali Adam, Hamzah Allam
Drafting of the manuscript: Ahmed Yaseen Alqutaibi, Dina Elawady, Ihab Ismail Mahmoud , Ahmed Atef Shon , Maya Ali Adam, Hamzah Allam
Critical review of the manuscript for important intellectual content: Ahmed Yaseen Alqutaibi, Dina Elawady, Ihab Ismail Mahmoud , Ahmed Atef Shon , Maya Ali Adam
Supervision: Ahmed Yaseen Alqutaibi, Ahmed Atef Shon
References
- 1.Implant overdentures: a new standard of care for edentulous patients current concepts and techniques. Vogel RC. https://pubmed.ncbi.nlm.nih.gov/18795644/ Compend Contin Educ Dent. 2008;29:270–276. [PubMed] [Google Scholar]
- 2.Mandibular overdentures supported by two or four endosteal implants. A prospective, comparative study. Batenburg RH, Raghoebar GM, Van Oort RP, Heijdenrijk K, Boering G. Int J Oral Maxillofac Surg. 1998;27:435–439. doi: 10.1016/s0901-5027(98)80032-5. [DOI] [PubMed] [Google Scholar]
- 3.Six-year clinical outcome of single implant-retained mandibular overdentures-a pilot study. Passia N, Wolfart S, Kern M. Clin Oral Implants Res. 2015;26:1191–1194. doi: 10.1111/clr.12427. [DOI] [PubMed] [Google Scholar]
- 4.Comparison of marginal bone loss and patient satisfaction in single and double-implant assisted mandibular overdenture by immediate loading. Tavakolizadeh S, Vafaee F, Khoshhal M, Ebrahimzadeh Z. J Adv Prosthodont. 2015;7:191–198. doi: 10.4047/jap.2015.7.3.191. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Treatment planning of the edentulous mandible. Chee W, Jivraj S. Br Dent J. 2006;201:337–347. doi: 10.1038/sj.bdj.4814041. [DOI] [PubMed] [Google Scholar]
- 6.Impact of screw retained versus cement retained implant-supported prosthesis on peri-implantitis: a systematic review and meta-analysis. Abdullah A, Al-Fahd A, Alsourori AA, Alqutaibi AY, Farouk M, Abbas N. https://www.researchgate.net/publication/284898408_Impact_of_screw_retained_versus_cement_retained_implant-supported_prosthesis_on_peri-implantitis_A_systematic_review_and_meta-analysis Int Dent Med J Adv Res. 2015;1:1–6. [Google Scholar]
- 7.Ceramic and metal-ceramic restorations for implant-supported prostheses showed similar complications and failure rate. Alqutaibi AY. J Evid Based Dent Pract. 2019;19:200–202. doi: 10.1016/j.jebdp.2019.05.007. [DOI] [PubMed] [Google Scholar]
- 8.Prosthodontic maintenance of fixed implant restorations vs. implant overdentures: a systematic review. Ibrahim WI, ElKhadem AH, Alqutaibi AY, Kaddah AF. Indian J Sci Technol. 2016;9:1–16. [Google Scholar]
- 9.Implant splinting in mandibular overdentures: a systematic review with meta-analysis of randomized clinical trials. Alqutaibi AY, Elawady DM. Quintessence Int. 2020;51:294–302. doi: 10.3290/j.qi.a44144. [DOI] [PubMed] [Google Scholar]
- 10.There is no evidence on the effect of the attachment system on implant survival rate, overdenture maintenance, or patient satisfaction. Alqutaibi AY. J Evid Based Dent Pract. 2015;15:193–194. doi: 10.1016/j.jebdp.2015.10.005. [DOI] [PubMed] [Google Scholar]
- 11.Limited evidence suggests a single implant overdenture as an alternative to two-implant-supported mandibular overdentures. Alqutaibi AY. J Evid Based Dent Pract. 2016;16:44–46. doi: 10.1016/j.jebdp.2016.01.009. [DOI] [PubMed] [Google Scholar]
- 12.Single vs two implant-retained overdentures for edentulous mandibles: a systematic review. Alqutaibi AY, Esposito M, Algabri R, Alfahad A, Kaddah A, Farouk M, Alsourori A. https://pubmed.ncbi.nlm.nih.gov/28944354/ Eur J Oral Implantol. 2017;10:243–261. [PubMed] [Google Scholar]
- 13.Effect of implant loading protocols on failure and marginal bone loss with unsplinted two-implant-supported mandibular overdentures: systematic review and meta-analysis. Helmy MH, Alqutaibi AY, El-Ella AA, Shawky AF. Int J Oral Maxillofac Surg. 2018;47:642–650. doi: 10.1016/j.ijom.2017.10.018. [DOI] [PubMed] [Google Scholar]
- 14.Prosthodontic maintenance and peri-implant tissue conditions for telescopic attachment-retained mandibular implant overdenture: systematic review and meta-analysis of randomized clinical trials. Keshk AM, Alqutaibi AY, Algabri RS, Swedan MS, Kaddah A. Eur J Dent. 2017;11:559–568. doi: 10.4103/ejd.ejd_23_17. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.No clear evidence regarding the effect of osteoporosis on dental implant failure. Alqutaibi AY, Radi IA. J Evid Based Dent Pract. 2016;16:124–126. doi: 10.1016/j.jebdp.2016.06.002. [DOI] [PubMed] [Google Scholar]
- 16.Limited evidence suggests high risk of implant failure rates among people with generalized aggressive periodontitis. Alqutaibi AY, Algabri RS. J Evid Based Dent Pract. 2015;15:187–189. doi: 10.1016/j.jebdp.2015.10.006. [DOI] [PubMed] [Google Scholar]
- 17.Does the adjunctive use of platelet-rich plasma to bone graft during sinus augmentation reduce implant failure and complication? Systematic review and meta-analysis. Abdalla RI, Alqutaibi AY, Kaddah A. Quintessence Int. 2018;49:139–146. doi: 10.3290/j.qi.a39616. [DOI] [PubMed] [Google Scholar]
- 18.Zygomatic Implants are a reliable treatment option for patients with atrophic maxilla. Alqutaibi AY, Aboalrejal A. J Evid Based Dent Pract. 2017;17:402–404. doi: 10.1016/j.jebdp.2017.10.004. [DOI] [PubMed] [Google Scholar]
- 19.Autogenous dentin grafts have comparable short-term outcomes to other graft materials regarding implant stability, preimplant marginal bone loss, and complication rate. Alqutaibi AY, Alnazzawi AA, Farghal A. J Evid Based Dent Pract. 2023;23:101844. doi: 10.1016/j.jebdp.2023.101844. [DOI] [PubMed] [Google Scholar]
- 20.Short dental implant is considered as a reliable treatment option for patients with atrophic posterior maxilla. Alqutaibi AY, Altaib F. J Evid Based Dent Pract. 2016;16:173–175. doi: 10.1016/j.jebdp.2016.07.003. [DOI] [PubMed] [Google Scholar]
- 21.Immediate and conventional loading of a single dental implant placed in the esthetic zone may yield comparable clinical outcomes. Alqutaibi AY, Hussain BS, Alobodi AK. J Evid Based Dent Pract. 2020;20:101492. doi: 10.1016/j.jebdp.2020.101492. [DOI] [PubMed] [Google Scholar]
- 22.Immediate dental implant placement with a horizontal gap more than two millimetres: a randomized clinical trial. Naji BM, Abdelsameaa SS, Alqutaibi AY, Said Ahmed WM. Int J Oral Maxillofac Surg. 2021;50:683–690. doi: 10.1016/j.ijom.2020.08.015. [DOI] [PubMed] [Google Scholar]
- 23.Impact of acrylic and silicone-based soft-liner materials on biting force and quality of life of the complete denture wearers: a randomized clinical trial. Alqutaibi AY, Alnazzawi AA, Farghal AE, Bakr RM, Mahmoud II. J Clin Med. 2023;12:2073. doi: 10.3390/jcm12052073. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Conventional tooth supported overdentures - case report: solutions for challenging situations. Verma P, Mangtani Kalra N, Kalra S, Garg S. https://openurl.ebsco.com/EPDB%3Agcd%3A5%3A12212453/detailv2?sid=ebsco%3Aplink%3Ascholar&id=ebsco%3Agcd%3A100705534&crl=c Indian J Dent Sci. 2014;6:0. [Google Scholar]
- 25.Tooth supported overdenture. A case report. Sisodiya S, Nagrat R, Srivastav A. Department of Prosthodontics K.D. Dental College & Hospital Mathura, India. 2014 [Google Scholar]
- 26.The glossary of prosthodontic terms: ninth edition. http://chrome-extension://efaidnbmnnnibpcajpcglclefindmkaj/https://jada.ada.org/pb/assets/raw/Health%20Advance/journals/ympr/pdfs/gpt9.pdf. J Prosthet Dent. 2017;117:0. doi: 10.1016/j.prosdent.2016.12.001. [DOI] [PubMed] [Google Scholar]
- 27.The influence of implant number on peri-implant marginal bone level and implant failures in mandibular implant overdentures. A systematic review with meta-analysis. Elawady DMA, Kaddah AF, Alqutaibi AY, Osman RB. https://www.journalijar.com/article/17868/the-influence-of-implant-number-on-peri-implant-marginal-bone-level-and-implant-failures-in-mandibular-implant-overdentures.-a-systematic-review-with-meta-analysis./ Int J Adv Res. 2017;5:1326–1334. [Google Scholar]
- 28.The implant-supported prosthesis for the edentulous arch: design considerations. Sadowsky SJ. J Prosthet Dent. 1997;78:28–33. doi: 10.1016/s0022-3913(97)70084-2. [DOI] [PubMed] [Google Scholar]
- 29.The implant-supported overdenture as an alternative to the complete mandibular denture. Doundoulakis JH, Eckert SE, Lindquist CC, Jeffcoat MK. J Am Dent Assoc. 2003;134:1455–1458. doi: 10.14219/jada.archive.2003.0073. [DOI] [PubMed] [Google Scholar]
- 30.Resnik R. St. Louis, MO: Mosby; 2020. Misch's Contemporary Implant Dentistry, 4th Edition. [Google Scholar]
- 31.Comparison between mainly mucosa-supported and combined mucosa-implant-supported mandibular overdentures. Assad AS, Abd El-Dayem MA, Badawy MM. Implant Dent. 2004;13:386–394. doi: 10.1097/01.id.0000144512.43654.08. [DOI] [PubMed] [Google Scholar]
- 32.Mandibular implant-retained overdenture: a clinical trial of two anchorage systems. Menicucci G, Lorenzetti M, Pera P, Preti G. https://pubmed.ncbi.nlm.nih.gov/9857597/ Int J Oral Maxillofac Implants. 1998;13:851–856. [PubMed] [Google Scholar]
- 33.A review of clinical and technical considerations for fixed and removable implant prostheses in the edentulous mandible. Zitzmann NU, Marinello CP. https://pubmed.ncbi.nlm.nih.gov/11887602/ Int J Prosthodont. 2002;15:65–72. [PubMed] [Google Scholar]
- 34.Overdenture attachment selection and the loading of implant and denture-bearing area. Part 2: a methodical study using five types of attachment. Heckmann SM, Winter W, Meyer M, Weber HP, Wichmann MG. Clin Oral Implants Res. 2001;12:640–647. doi: 10.1034/j.1600-0501.2001.120613.x. [DOI] [PubMed] [Google Scholar]
- 35.In vitro retention force changes of prefabricated attachments for overdentures. Besimo CE, Guarneri A. J Oral Rehabil. 2003;30:671–678. doi: 10.1046/j.1365-2842.2003.01140.x. [DOI] [PubMed] [Google Scholar]
- 36.Clinical evaluation of overdenture restorations supported by osseointegrated titanium implants: a retrospective study. Mericske-Stern R. https://pubmed.ncbi.nlm.nih.gov/2094656/ Int J Oral Maxillofac Implants. 1990;5:375–383. [PubMed] [Google Scholar]
- 37.The psychological impact of implant-retained mandibular prostheses: a cross-sectional study. Humphris GM, Healey T, Howell RA, Cawood J. https://pubmed.ncbi.nlm.nih.gov/7672846/ Int J Oral Maxillofac Implants. 1995;10:437–444. [PubMed] [Google Scholar]
- 38.Implant-supported overdentures: a longitudinal prospective study. Bergendal T, Engquist B. https://pubmed.ncbi.nlm.nih.gov/9581412/ Int J Oral Maxillofac Implants. 1998;13:253–262. [PubMed] [Google Scholar]
- 39.In vivo measurements of maximal occlusal force and minimal pressure threshold on overdentures supported by implants or natural roots: a comparative study, part 1. Mericske-Stern R, Hofmann J, Wedig A, Geering AH. https://pubmed.ncbi.nlm.nih.gov/8181826/ Int J Oral Maxillofac Implants. 1993;8:641–649. [PubMed] [Google Scholar]
- 40.Implant-retained mandibular overdentures compared with complete dentures; a 5-years' follow-up study of clinical aspects and patient satisfaction. Meijer HJ, Raghoebar GM, Van't Hof MA, Geertman ME, Van Oort RP. Clin Oral Implants Res. 1999;10:238–244. doi: 10.1034/j.1600-0501.1999.100307.x. [DOI] [PubMed] [Google Scholar]
- 41.The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Feine JS, Carlsson GE, Awad MA, et al. https://pubmed.ncbi.nlm.nih.gov/12164236/ Gerodontology. 2002;19:3–4. [PubMed] [Google Scholar]
- 42.Effect of mandibular ridge height on masticatory performance with mandibular conventional and implant-assisted overdentures. Kimoto K, Garrett NR. https://pubmed.ncbi.nlm.nih.gov/12939003/ Int J Oral Maxillofac Implants. 2003;18:523–530. [PubMed] [Google Scholar]
- 43.Misch CE. St. Louis, MO: Mosby; 2008. Contemporary Implant Dentistry - 3rd Edition. [Google Scholar]
- 44.Problems with prostheses on implants: a retrospective study. Walton JN, MacEntee MI. J Prosthet Dent. 1994;71:283–288. doi: 10.1016/0022-3913(94)90468-5. [DOI] [PubMed] [Google Scholar]
- 45.A 5-year prospective randomized clinical trial on the influence of splinted and unsplinted oral implants retaining a mandibular overdenture: prosthetic aspects and patient satisfaction. Naert I, Gizani S, Vuylsteke M, Van Steenberghe D. J Oral Rehabil. 1999;26:195–202. doi: 10.1046/j.1365-2842.1999.00369.x. [DOI] [PubMed] [Google Scholar]
- 46.Implant-supported mandibular overdentures retained with ball or bar attachments: a randomized prospective 5-year study. Gotfredsen K, Holm B. https://pubmed.ncbi.nlm.nih.gov/11203620/ Int J Prosthodont. 2000;13:125–130. [PubMed] [Google Scholar]
- 47.Posterior jaw bone resorption in osseointegrated implant-supported overdentures. Jacobs R, Schotte A, van Steenberghe D, Quirynen M, Naert I. Clin Oral Implants Res. 1992;3:63–70. doi: 10.1034/j.1600-0501.1992.030203.x. [DOI] [PubMed] [Google Scholar]
- 48.The single midline implant in the edentulous mandible—current status of clinical trials. Passia N, Kern M. J Clin Med. 2023;12:3773. doi: 10.3390/jcm12113773. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.The revised CONSORT statement for reporting randomized trials: explanation and elaboration. Altman DG, Schulz KF, Moher D, et al. Ann Intern Med. 2001;134:663–694. doi: 10.7326/0003-4819-134-8-200104170-00012. [DOI] [PubMed] [Google Scholar]
- 50.The effect of single-implant overdentures on cognitive function in older adults: a 3-year follow-up report. Komagamine Y, Kanazawa M, Miyayasu A, et al. J Dent. 2023;136:104632. doi: 10.1016/j.jdent.2023.104632. [DOI] [PubMed] [Google Scholar]
- 51.The symphyseal single-tooth implant for anchorage of a mandibular complete denture in geriatric patients: a clinical report. Krennmair G, Ulm C. https://pubmed.ncbi.nlm.nih.gov/11280368/ Int J Oral Maxillofac Implants. 2001;16:98–104. [PubMed] [Google Scholar]
- 52.Comparison of the quality of life among the immediate loading implant overdentures using the single and the double implants: an original study. Dewan H, Mansuri S, Bansal K, Basutkar N, Saini M, Nayan K. J Pharm Bioallied Sci. 2023;15:0–5. doi: 10.4103/jpbs.jpbs_444_22. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53.Mandibular overdentures anchored to single implants: a five-year prospective study. Cordioli G, Majzoub Z, Castagna S. J Prosthet Dent. 1997;78:159–165. doi: 10.1016/s0022-3913(97)70120-3. [DOI] [PubMed] [Google Scholar]
- 54.Biomechanical rationale for a single implant-retained mandibular overdenture: an in vitro study. Maeda Y, Horisaka M, Yagi K. Clin Oral Implants Res. 2008;19:271–275. doi: 10.1111/j.1600-0501.2007.01425.x. [DOI] [PubMed] [Google Scholar]
- 55.Influence of implant number on the biomechanical behaviour of mandibular implant-retained/supported overdentures: a three-dimensional finite element analysis. Liu J, Pan S, Dong J, Mo Z, Fan Y, Feng H. J Dent. 2013;41:241–249. doi: 10.1016/j.jdent.2012.11.008. [DOI] [PubMed] [Google Scholar]
- 56.Rotational movements of mandibular two-implant overdentures. Kimoto S, Pan S, Drolet N, Feine JS. Clin Oral Implants Res. 2009;20:838–843. doi: 10.1111/j.1600-0501.2009.01723.x. [DOI] [PubMed] [Google Scholar]
- 57.Mandibular implant-supported overdenture: a systematic review and meta-analysis for optimum selection of attachment system. Sutariya PV, Shah HM, Patel SD, Upadhyay HH, Pathan MR, Shah RP. J Indian Prosthodont Soc. 2021;21:319–327. doi: 10.4103/jips.jips_158_21. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 58.The central single implant in the edentulous mandible: improvement of function and quality of life. A report of 2 cases. Wolfart S, Braasch K, Brunzel S, Kern M. https://pubmed.ncbi.nlm.nih.gov/19107261/ Quintessence Int. 2008;39:541–548. [PubMed] [Google Scholar]
- 59.Clinical performance and material properties of single-implant overdenture attachment systems. Alsabeeha NH, Swain MV, Payne AG. https://pubmed.ncbi.nlm.nih.gov/21519573/ Int J Prosthodont. 2011;24:247–254. [PubMed] [Google Scholar]
- 60.Resistance to wear of four matrices with ball attachments for implant overdentures: a fatigue study. Branchi R, Vangi D, Virga A, Guertin G, Fazi G. J Prosthodont. 2010;19:614–619. doi: 10.1111/j.1532-849X.2010.00613.x. [DOI] [PubMed] [Google Scholar]
- 61.Implant-supported mandibular overdentures retained with ball or telescopic crown attachments: a 3-year prospective study. Krennmair G, Weinländer M, Krainhöfner M, Piehslinger E. https://pubmed.ncbi.nlm.nih.gov/16602365/ Int J Prosthodont. 2006;19:164–170. [PubMed] [Google Scholar]
- 62.Mandibular single-implant overdentures: a review with surgical and prosthodontic perspectives of a novel approach. Alsabeeha N, Payne AG, De Silva RK, Swain MV. Clin Oral Implants Res. 2009;20:356–365. doi: 10.1111/j.1600-0501.2008.01666.x. [DOI] [PubMed] [Google Scholar]
- 63.Fracture incidence in mandibular overdentures retained by one or two implants. Gonda T, Maeda Y, Walton JN, MacEntee MI. J Prosthet Dent. 2010;103:178–181. doi: 10.1016/S0022-3913(10)60026-1. [DOI] [PubMed] [Google Scholar]
- 64.Metal-reinforced single implant mandibular overdenture retained by an attachment: a clinical report. Grageda E, Rieck B. https://www.sciencedirect.com/science/article/abs/pii/S0022391313001649. J Prosthet Dent. 2014;111:16–19. doi: 10.1016/j.prosdent.2013.07.009. [DOI] [PubMed] [Google Scholar]
- 65.Use of a single implant to retain a mandibular complete overdenture on the compromised atrophic alveolar ridge: a case report. Schneider GB, Synan WJ. Spec Care Dentist. 2011;31:138–142. doi: 10.1111/j.1754-4505.2011.00196.x. [DOI] [PubMed] [Google Scholar]
- 66.Principles of occlusion for implant prostheses: guidelines for position, timing, and force of occlusal contacts. Chapman RJ. https://pubmed.ncbi.nlm.nih.gov/2697023/ Quintessence Int. 1989;20:473–480. [PubMed] [Google Scholar]
- 67.Long-term treatment outcomes in edentulous patients with implant overdentures: the Toronto study. Attard NJ, Zarb GA. https://pubmed.ncbi.nlm.nih.gov/15382778/ Int J Prosthodont. 2004;17:425–433. [PubMed] [Google Scholar]
- 68.Prosthetic aspects of osseointegrated fixtures supporting overdentures. A 4-year report. Naert I, Quirynen M, Theuniers G, van Steenberghe D. https://www.sciencedirect.com/science/article/abs/pii/002239139190205B. J Prosthet Dent. 1991;65:671–680. doi: 10.1016/0022-3913(91)90205-b. [DOI] [PubMed] [Google Scholar]
- 69.Single-implant overdentures retained by a novel attachment: a mixed methods crossover randomized clinical trial. de Souza RF, Jabbar AA, Jafarpour D, et al. JDR Clin Trans Res. 2024;9:27–41. doi: 10.1177/23800844221124083. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 70.Implant survival in 1- versus 2-implant mandibular overdentures: a systematic review and meta-analysis. Srinivasan M, Makarov NA, Herrmann FR, Müller F. Clin Oral Implants Res. 2016;27:63–72. doi: 10.1111/clr.12513. [DOI] [PubMed] [Google Scholar]
- 71.Clinical viability of single implant-retained mandibular overdentures: a systematic review and meta-analysis. de Souza Batista VE, Vechiato-Filho AJ, Santiago JF Jr, et al. Int J Oral Maxillofac Surg. 2018;47:1166–1177. doi: 10.1016/j.ijom.2018.01.021. [DOI] [PubMed] [Google Scholar]
- 72.Mandibular complete denture versus single-implant overdenture: a systematic review of patient-reported outcomes. Nogueira TE, Dias DR, Leles CR. J Oral Rehabil. 2017;44:1004–1016. doi: 10.1111/joor.12550. [DOI] [PubMed] [Google Scholar]
- 73.Single vs 2 implants on peri-implant marginal bone level and implant failures in mandibular implant overdentures: a systematic review with meta-analysis. Ahmed Elawady DM, Kaddah AF, Talaat Khalifa M. J Evid Based Dent Pract. 2017;17:216–225. doi: 10.1016/j.jebdp.2017.02.002. [DOI] [PubMed] [Google Scholar]
- 74.Patient satisfaction and crestal bone changes with one-piece and two-piece single implant-retained mandibular overdenture: a randomized controlled clinical study. Singh S, Mishra SK, Chowdhary R. J Prosthodont Res. 2023;67:112–120. doi: 10.2186/jpr.JPR_D_20_00315. [DOI] [PubMed] [Google Scholar]
- 75.A prospective study of immediately loaded single implant-retained mandibular overdentures: preliminary one-year results. Liddelow GJ, Henry PJ. J Prosthet Dent. 2007;97:0–37. doi: 10.1016/S0022-3913(07)60016-X. [DOI] [PubMed] [Google Scholar]
- 76.Mandibular single-implant overdentures: preliminary results of a randomised-control trial on early loading with different implant diameters and attachment systems. Alsabeeha NH, Payne AG, De Silva RK, Thomson WM. Clin Oral Implants Res. 2011;22:330–337. doi: 10.1111/j.1600-0501.2010.02004.x. [DOI] [PubMed] [Google Scholar]
- 77.Single implant retained overdenture treatment protocol: a systematic review and meta-analysis. Padmanabhan H, Kumar SM, Kumar VA. J Prosthodont. 2020;29:287–297. doi: 10.1111/jopr.13133. [DOI] [PubMed] [Google Scholar]
- 78.The immediately loaded single implant-retained mandibular overdenture: a 36-month prospective study. Liddelow G, Henry P. https://pubmed.ncbi.nlm.nih.gov/20234886/ Int J Prosthodont. 2010;23:13–21. [PubMed] [Google Scholar]
- 79.Three-year clinical outcome of single implant-retained mandibular overdentures-results of preliminary prospective study. Harder S, Wolfart S, Egert C, Kern M. J Dent. 2011;39:656–661. doi: 10.1016/j.jdent.2011.07.007. [DOI] [PubMed] [Google Scholar]
- 80.Use of a single implant to retain mandibular overdenture: a preliminary clinical trial of 13 cases. Cheng T, Ma L, Liu XL, Sun GF, He XJ, Huo JY, Wang YN. https://www.sciencedirect.com/science/article/pii/S1991790212000682 J Dent Sci. 2012;7:261–266. [Google Scholar]
- 81.A prospective randomized study on the immediate loading of mandibular overdentures supported by one or two implants; a 3 year follow-up report. Kronstrom M, Davis B, Loney R, Gerrow J, Hollender L. Clin Implant Dent Relat Res. 2014;16:323–329. doi: 10.1111/cid.12006. [DOI] [PubMed] [Google Scholar]
- 82.A 5-year randomized trial to compare 1 or 2 implants for implant overdentures. Bryant SR, Walton JN, MacEntee MI. J Dent Res. 2015;94:36–43. doi: 10.1177/0022034514554224. [DOI] [PubMed] [Google Scholar]
- 83.Single mandibular implant study - denture satisfaction in the elderly. Passia N, Att W, Freitag-Wolf S, et al. J Oral Rehabil. 2017;44:213–219. doi: 10.1111/joor.12473. [DOI] [PubMed] [Google Scholar]
- 84.Randomized study on the effect of single-implant versus two-implant retained overdentures on implant loss and muscle activity: a 12-month follow-up report. Alqutaibi AY, Kaddah AF, Farouk M. Int J Oral Maxillofac Surg. 2017;46:789–797. doi: 10.1016/j.ijom.2017.02.001. [DOI] [PubMed] [Google Scholar]
- 85.A 2-year prospective study of single-implant mandibular overdentures: patient-reported outcomes and prosthodontic events. Nogueira TE, Aguiar FM, de Barcelos BA, Leles CR. Clin Oral Implants Res. 2018;29:541–550. doi: 10.1111/clr.13151. [DOI] [PubMed] [Google Scholar]
- 86.Psychometric analysis and masticatory efficiency of elderly people with single-implant overdentures. Amaral CF, Pinheiro MA, de Moraes M, Rodrigues Garcia RC. Int J Oral Maxillofac Implants. 2018;33:1383–1389. doi: 10.11607/jomi.6557. [DOI] [PubMed] [Google Scholar]
- 87.Comparison between patient satisfaction and biting force in a single implant overdenture and two-implants overdenture: a randomized clinical trial. Al-Fahd A, Abbas N, Farouk M. https://researchgate.net/publication/327157486_Comparison_Between_Patient_Satisfaction_And_Biting_Force_In_A_Single_Implant_Overdenture_And_Two-Implants_Overdenture_A_Randomized_Clinical_Trial Int Dent Med J Adv Res. 2018;4:1–7. [Google Scholar]
- 88.The use of ballclip attachments with an implant-supported primary-secondary bar overdenture. Steffen RP, White V, Markowitz NR. https://meridian.allenpress.com/joi/article/30/4/234/1941/The-Use-of-Ball-clip-Attachments-with-an-Implant. J Oral Implantol. 2004;30:234–239. doi: 10.1563/0.661.1. [DOI] [PubMed] [Google Scholar]
- 89.Preiskel HW. Vol. 189. London, UK: Quintessence Publishing Co Ltd; 1999. Overdentures Made Easy A Guide To Implant and Root Supported Prostheses; p. 43. [Google Scholar]
- 90.Effect of anchorage systems and extension base contact on load transfer with mandibular implant-retained overdentures. Sadowsky SJ, Caputo AA. J Prosthet Dent. 2000;84:327–334. doi: 10.1067/mpr.2000.109378. [DOI] [PubMed] [Google Scholar]
- 91.The role of abutment-attachment selection in resolving inadequate interarch distance: a clinical report. Alsiyabi AS, Felton DA, Cooper LF. J Prosthodont. 2005;14:184–190. doi: 10.1111/j.1532-849X.2005.04029.x. [DOI] [PubMed] [Google Scholar]
- 92.Effect of implant angulation upon retention of overdenture attachments. Gulizio MP, Agar JR, Kelly JR, Taylor TD. J Prosthodont. 2005;14:3–11. doi: 10.1111/j.1532-849X.2005.00005.x. [DOI] [PubMed] [Google Scholar]
- 93.Influence of attachment wear on retention of mandibular overdenture. Rutkunas V, Mizutani H, Takahashi H. J Oral Rehabil. 2007;34:41–51. doi: 10.1111/j.1365-2842.2006.01640.x. [DOI] [PubMed] [Google Scholar]
- 94.Effect of dislodging forces on mandibular implant attachment-retained overdenture. Elkerdawy MW, Radi IA. Implant Dent. 2011;20:246–254. doi: 10.1097/ID.0b013e318211fe1b. [DOI] [PubMed] [Google Scholar]
- 95.The influence of interimplant distance and attachment type on the retention characteristics of mandibular overdentures on 2 implants: 6-month fatigue retention values. Doukas D, Michelinakis G, Smith PW, Barclay CW. https://pubmed.ncbi.nlm.nih.gov/18546771/ Int J Prosthodont. 2008;21:152–154. [PubMed] [Google Scholar]
- 96.A classification of precision attachments. Becerra G, MacEntee M. J Prosthet Dent. 1987;58:322–327. doi: 10.1016/0022-3913(87)90049-7. [DOI] [PubMed] [Google Scholar]
- 97.Retention and postinsertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function. van Kampen F, Cune M, van der Bilt A, Bosman F. Clin Oral Implants Res. 2003;14:720–726. doi: 10.1046/j.0905-7161.2003.00961.x. [DOI] [PubMed] [Google Scholar]
- 98.In vitro study of a mandibular implant overdenture retained with ball, magnet, or bar attachments: comparison of load transfer and denture stability. Tokuhisa M, Matsushita Y, Koyano K. https://pubmed.ncbi.nlm.nih.gov/12737242/ Int J Prosthodont. 2003;16:128–134. [PubMed] [Google Scholar]
- 99.Baer ML. J Prosthodont. Vol. 9. Mosby Inc, ; 2000. Implant prosthodontics: clinical and laboratory procedures; pp. 249–250. [Google Scholar]
- 100.Care of edentulous mandible with implant stabilized telescope complete denture [Article in German] Keller U, Haase C. https://pubmed.ncbi.nlm.nih.gov/1817394/ ZWR. 1991;100:640-4, 646-7. [PubMed] [Google Scholar]
- 101.Mandibular two-implant telescopic overdentures. Heckmann SM, Schrott A, Graef F, Wichmann MG, Weber HP. Clin Oral Implants Res. 2004;15:560–569. doi: 10.1111/j.1600-0501.2004.01064.x. [DOI] [PubMed] [Google Scholar]
- 102.Retentive and stabilizing properties of stud and magnetic attachments retaining mandibular overdenture. An in vitro study. Rutkunas V, Mizutani H. https://www.sbdmj.com/043/043-05.pdf Stomatologija. 2004;6:85–90. [Google Scholar]
- 103.Complications associated with the ball, bar and Locator attachments for implant-supported overdentures. Cakarer S, Can T, Yaltirik M, Keskin C. Med Oral Patol Oral Cir Bucal. 2011;16:0–9. doi: 10.4317/medoral.17312. [DOI] [PubMed] [Google Scholar]
- 104.Evaluation of masticatory muscle activity and survival rate of single implant-retained mandibular overdenture fabricated from thermoplastic versus conventional acrylic resin. A randomized controlled trial. Ibrahim W, Elawady D. Egypt Dent J. 2021;67571:581. [Google Scholar]
- 105.Over-dentures and attachments: a review of literature. Samantaray RK, Nanda K, Sahoo D. Indian J Forensic Med Toxicol. 2020;14:8662–8666. [Google Scholar]
- 106.The overdenture. Brewer AA, Fenton AH. https://www.sciencedirect.com/science/article/abs/pii/S001185322200708X. Dent Clin North Am. 1973;17:723–713. [PubMed] [Google Scholar]
- 107.A prosthetic solution to restoring the edentulous mandible with limited interarch space using an implant-tissue-supported overdenture: a clinical report. Pasciuta M, Grossmann Y, Finger IM. J Prosthet Dent. 2005;93:116–120. doi: 10.1016/j.prosdent.2004.09.024. [DOI] [PubMed] [Google Scholar]
- 108.Fabrication of custom clips for bar-and-clip attachments for implant-supported overdentures. Bolouri A, Zartman RR. J Prosthet Dent. 2006;96:379–380. doi: 10.1016/j.prosdent.2006.08.018. [DOI] [PubMed] [Google Scholar]
- 109.Overdenture retention and stabilization with ball-and-socket attachments: principles and technique. Banton B, Henry MD. https://pubmed.ncbi.nlm.nih.gov/9524489/ J Dent Technol. 1997;14:14–20. [PubMed] [Google Scholar]
- 110.A quality-of-life comparison between self-aligning and ball attachment systems for 2-implant-retained mandibular overdentures. Bilhan H, Geckili O, Sulun T, Bilgin T. J Oral Implantol. 2011;37 Spec No:167–173. doi: 10.1563/AAID-JOI-D-10-00070. [DOI] [PubMed] [Google Scholar]
- 111.Restoration of divergent free-standing implants in the maxilla. Schneider AL, Kurtzman GM. J Oral Implantol. 2002;28:113–116. doi: 10.1563/1548-1336(2002)028<0113:RODFII>2.3.CO;2. [DOI] [PubMed] [Google Scholar]
- 112.Preiskel HW. St. Louis, MO: Mosby; 1984. Precision Attachments in Dentistry . [Google Scholar]
- 113.Baker JL, Goodkind RJ. St. Louis, MO: Mosby; 1981. Theory and practice of precision attachment removable partial denture; CV. [Google Scholar]
- 114.Bar overdentures utilizing the Locator attachment. Schneider AL, Kurtzman GM. https://pubmed.ncbi.nlm.nih.gov/12004703/ Gen Dent. 2001;49:210–214. [PubMed] [Google Scholar]
- 115.A comparison of three different attachment systems for mandibular two-implant overdentures: one-year report. Kleis WK, Kämmerer PW, Hartmann S, Al-Nawas B, Wagner W. Clin Implant Dent Relat Res. 2010;12:209–218. doi: 10.1111/j.1708-8208.2009.00154.x. [DOI] [PubMed] [Google Scholar]
- 116.Clinical outcomes of three Parkinson's disease patients treated with mandibular implant overdentures. Heckmann SM, Heckmann JG, Weber HP. Clin Oral Implants Res. 2000;11:566–571. doi: 10.1034/j.1600-0501.2000.011006566.x. [DOI] [PubMed] [Google Scholar]
- 117.A longitudinal clinical assessment of spark erosion technology in implant-retained overdenture prostheses: a preliminary report. Toljanic JA, Antoniou D, Clark RS, Graham L. J Prosthet Dent. 1997;78:490–495. doi: 10.1016/s0022-3913(97)70065-9. [DOI] [PubMed] [Google Scholar]
- 118.Treatment outcome with implant-retained overdentures: part II--patient satisfaction and predictability of subjective treatment outcome. Cune MS, de Putter C, Hoogstraten J. J Prosthet Dent. 1994;72:152–158. doi: 10.1016/0022-3913(94)90073-6. [DOI] [PubMed] [Google Scholar]
- 119.Prospective clinical evaluation of mandibular implant overdentures: part I--retention, stability, and tissue response. Burns DR, Unger JW, Elswick RK Jr, Beck DA. J Prosthet Dent. 1995;73:354–363. doi: 10.1016/s0022-3913(05)80331-2. [DOI] [PubMed] [Google Scholar]
- 120.A 5-year prospective multicenter follow-up report on overdentures supported by osseointegrated implants. Jemt T, Chai J, Harnett J, et al. https://pubmed.ncbi.nlm.nih.gov/8752550/ Int J Oral Maxillofac Implants. 1996;11:291–298. [PubMed] [Google Scholar]
- 121.Comparison of retention and strain energies of stud attachments for implant overdentures. Petropoulos VC, Mante FK. J Prosthodont. 2011;20:286–293. doi: 10.1111/j.1532-849X.2011.00699.x. [DOI] [PubMed] [Google Scholar]
- 122.Prosthetic aspects and patient satisfaction with two-implant-retained mandibular overdentures: a 10-year randomized clinical study. Naert I, Alsaadi G, Quirynen M. https://pubmed.ncbi.nlm.nih.gov/15382775/ Int J Prosthodont. 2004;17:401–410. [PubMed] [Google Scholar]
- 123.Using restorations borne totally by anterior implants to preserve the edentulous mandible. Davis WH, Lam PS, Marshall MW, Dorchester W, Hochwald DA, Kaminishi RM. J Am Dent Assoc. 1999;130:1183–1189. doi: 10.14219/jada.archive.1999.0372. [DOI] [PubMed] [Google Scholar]
- 124.A 5-year randomized clinical trial on the influence of splinted and unsplinted oral implants in the mandibular overdenture therapy. Part I: peri-implant outcome. Naert I, Gizani S, Vuylsteke M, van Steenberghe D. Clin Oral Implants Res. 1998;9:170–177. doi: 10.1034/j.1600-0501.1998.090304.x. [DOI] [PubMed] [Google Scholar]
- 125.One-year prosthetic outcomes with implant overdentures: a randomized clinical trial. Walton JN, MacEntee MI, Glick N. https://pubmed.ncbi.nlm.nih.gov/12074455/ Int J Oral Maxillofac Implants. 2002;17:391–398. [PubMed] [Google Scholar]
- 126.Masticatory function and patient satisfaction with implant-supported mandibular overdentures: a prospective 5-year study. Bakke M, Holm B, Gotfredsen K. https://pubmed.ncbi.nlm.nih.gov/12475165/ Int J Prosthodont. 2002;15:575–581. [PubMed] [Google Scholar]
- 127.Patient satisfaction and masticatory efficiency of single implant-retained mandibular overdentures using the stud and magnetic attachments. Cheng T, Sun G, Huo J, He X, Wang Y, Ren YF. J Dent. 2012;40:1018–1023. doi: 10.1016/j.jdent.2012.08.011. [DOI] [PubMed] [Google Scholar]
- 128.Implant overdentures: selections for attachment systems. Massad JJ, Ahuja S, Cagna D. https://pubmed.ncbi.nlm.nih.gov/23431878/ Dent Today. 2013;32:128, 130-2. [PubMed] [Google Scholar]
- 129.Mandibular two-implant overdentures: three-year prosthodontic maintenance using the locator attachment system. Mackie A, Lyons K, Thomson WM, Payne AG. https://pubmed.ncbi.nlm.nih.gov/21716970/ Int J Prosthodont. 2011;24:328–331. [PubMed] [Google Scholar]
- 130.Principles of attachment selection for implant-supported overdentures and their impact on surgical approaches. Shafie H, Obeid G. http://chrome-extension://efaidnbmnnnibpcajpcglclefindmkaj/https://selectedreadingsoms.com/pdf/Volume19.6.pdf Sel Read. 2011;19:1–36. [Google Scholar]
- 131.A systematic review of implant-supported maxillary overdentures after a mean observation period of at least 1 year. Slot W, Raghoebar GM, Vissink A, Huddleston Slater JJ, Meijer HJ. J Clin Periodontol. 2010;37:98–110. doi: 10.1111/j.1600-051X.2009.01493.x. [DOI] [PubMed] [Google Scholar]
- 132.Surgical and prosthetic planning for a two-implant-retained mandibular overdenture: a clinical report. Lee CK, Agar JR. J Prosthet Dent. 2006;95:102–105. doi: 10.1016/j.prosdent.2005.11.017. [DOI] [PubMed] [Google Scholar]
- 133.Root-supported overdentures. Pavlatos J. https://pubmed.ncbi.nlm.nih.gov/9790013/ CDS Rev. 1998;91:20–25. [PubMed] [Google Scholar]
- 134.Two versus three narrow-diameter implants with locator attachments supporting mandibular overdentures: a two-year prospective study. El-Sheikh AM, Shihabuddin OF, Ghoraba SM. Int J Dent. 2012;2012:285684. doi: 10.1155/2012/285684. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 135.A comparative in vitro study on the retention and stability of implant-supported overdentures. Sadig W. https://pubmed.ncbi.nlm.nih.gov/19417876/ Quintessence Int. 2009;40:313–319. [PubMed] [Google Scholar]
- 136.Single unit attachments improve peri-implant soft tissue conditions in mandibular overdentures supported by four implants. Cordaro L, di Torresanto VM, Petricevic N, Jornet PR, Torsello F. Clin Oral Implants Res. 2013;24:536–542. doi: 10.1111/j.1600-0501.2012.02426.x. [DOI] [PubMed] [Google Scholar]
- 137.Stud attachments for the mandibular implant-retained overdentures: prosthetic complications. A literature review. Daou EE. Saudi Dent J. 2013;25:53–60. doi: 10.1016/j.sdentj.2012.12.003. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 138.The change in retentive values of locator attachments and hader clips over time. Evtimovska E, Masri R, Driscoll CF, Romberg E. J Prosthodont. 2009;18:479–483. doi: 10.1111/j.1532-849X.2009.00474.x. [DOI] [PubMed] [Google Scholar]
- 139.Retention characteristics of different attachment systems of mandibular overdentures retained by two or three implants. Uludag B, Polat S. https://pubmed.ncbi.nlm.nih.gov/23189303/ Int J Oral Maxillofac Implants. 2012;27:1509–1513. [PubMed] [Google Scholar]
- 140.Immediate versus delayed loading of two implants supporting a locator retained mandibular overdenture. A randomized controlled study. Thacker SR. https://digitalcommons.lib.uconn.edu/gs_theses/305/ Master's Theses. 2012:305. doi: 10.11607/jomi.4118. [DOI] [PubMed] [Google Scholar]
- 141.The locator attachment: free-standing versus bar-overdentures. Kurtzman GM, Mahesh L. http://www.centrefordentalimplant.com/wp-content/uploads/2011/05/The-Locator-Attachment.pdf Famdent. 2008;9:1–3. [Google Scholar]