Abstract
BACKGROUND: A new portable spirometer, the Spirophone, has been developed that records a subject's blow and can then transmit all the data by telephone to a receiving centre for analysis and comment. Tests of this device were undertaken to determine its accuracy and reliability. METHODS: The performance of the Spirophone was tested using computer generated wave forms, by delivering blows from calibrated syringes at different flows, and by comparing subjects' blows with those recorded with a commercial spirometer. RESULTS: Using computer generated wave forms all lung function indices were accurate to within 1% and blows delivered from calibrating syringes were accurate to within 5%. When subjects performed repeated forced vital capacity (FVC) manoeuvres there were no significant differences between lung function indices recorded with the Spirophone and with a commercial spirometer. With the Spirophone and commercial spirometer in series the FVC and forced expiratory volume in one second (FEV1) were within 5% of each other in nine out of 10 healthy subjects. CONCLUSION: The Spirophone recorded maximal forced expiratory manoeuvres with acceptable accuracy, reliability, and reproducibility, and this system offers the ability to monitor a patient's lung function at a centre remote from the patient.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Beasley R., Cushley M., Holgate S. T. A self management plan in the treatment of adult asthma. Thorax. 1989 Mar;44(3):200–204. doi: 10.1136/thx.44.3.200. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bland J. M., Altman D. G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986 Feb 8;1(8476):307–310. [PubMed] [Google Scholar]
- Bosken C. H., Wiggs B. R., Paré P. D., Hogg J. C. Small airway dimensions in smokers with obstruction to airflow. Am Rev Respir Dis. 1990 Sep;142(3):563–570. doi: 10.1164/ajrccm/142.3.563. [DOI] [PubMed] [Google Scholar]
- Evans R., 3rd, Mullally D. I., Wilson R. W., Gergen P. J., Rosenberg H. M., Grauman J. S., Chevarley F. M., Feinleib M. National trends in the morbidity and mortality of asthma in the US. Prevalence, hospitalization and death from asthma over two decades: 1965-1984. Chest. 1987 Jun;91(6 Suppl):65S–74S. [PubMed] [Google Scholar]
- FitzGerald M. X., Smith A. A., Gaensler E. A. Evaluation of "electronic" spirometers. N Engl J Med. 1973 Dec 13;289(24):1283–1288. doi: 10.1056/NEJM197312132892406. [DOI] [PubMed] [Google Scholar]
- Gardner R. M., Hankinson J. L., West B. J. Evaluating commercially available spirometers. Am Rev Respir Dis. 1980 Jan;121(1):73–82. doi: 10.1164/arrd.1980.121.1.73. [DOI] [PubMed] [Google Scholar]
- Gergen P. J., Weiss K. B. The increasing problem of asthma in the United States. Am Rev Respir Dis. 1992 Oct;146(4):823–824. doi: 10.1164/ajrccm/146.4.823. [DOI] [PubMed] [Google Scholar]
- Gunawardena K. A., Houston K., Smith A. P. Evaluation of the turbine pocket spirometer. Thorax. 1987 Sep;42(9):689–693. doi: 10.1136/thx.42.9.689. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hetzel M. R., Williams I. P., Shakespeare R. M. Can patients keep their own peak-flow records reliably? Lancet. 1979 Mar 17;1(8116):597–599. doi: 10.1016/s0140-6736(79)91019-5. [DOI] [PubMed] [Google Scholar]
- Hosie H. E., Nimmo W. S. Measurement of FEV1 and FVC. Comparison of a pocket spirometer with the Vitalograph. Anaesthesia. 1988 Mar;43(3):233–238. [PubMed] [Google Scholar]
- James A. L., Paré P. D., Hogg J. C. The mechanics of airway narrowing in asthma. Am Rev Respir Dis. 1989 Jan;139(1):242–246. doi: 10.1164/ajrccm/139.1.242. [DOI] [PubMed] [Google Scholar]
- Johns D. P., Abramson M., Bowes G. Evaluation of a new ambulatory spirometer for measuring forced expiratory volume in one second and peak expiratory flow rate. Am Rev Respir Dis. 1993 May;147(5):1245–1250. doi: 10.1164/ajrccm/147.5.1245. [DOI] [PubMed] [Google Scholar]
- Jones K. P., Mullee M. A. Measuring peak expiratory flow in general practice: comparison of mini Wright peak flow meter and turbine spirometer. BMJ. 1990 Jun 23;300(6740):1629–1631. doi: 10.1136/bmj.300.6740.1629. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kuwano K., Bosken C. H., Paré P. D., Bai T. R., Wiggs B. R., Hogg J. C. Small airways dimensions in asthma and in chronic obstructive pulmonary disease. Am Rev Respir Dis. 1993 Nov;148(5):1220–1225. doi: 10.1164/ajrccm/148.5.1220. [DOI] [PubMed] [Google Scholar]
- Miller M. R., Dickinson S. A., Hitchings D. J. The accuracy of portable peak flow meters. Thorax. 1992 Nov;47(11):904–909. doi: 10.1136/thx.47.11.904. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Miller M. R., Pincock A. C. Linearity and temperature control of the Fleisch pneumotachograph. J Appl Physiol (1985) 1986 Feb;60(2):710–715. doi: 10.1152/jappl.1986.60.2.710. [DOI] [PubMed] [Google Scholar]
- Miller M. R., Sigsgaard T. Prevention of thermal and condensation errors in pneumotachographic recordings of the maximal forced expiratory manoeuvre. Eur Respir J. 1994 Jan;7(1):198–201. doi: 10.1183/09031936.94.07010198. [DOI] [PubMed] [Google Scholar]
- Murray A. B., Hardwick D. F., Pirie G. E., Fraser B. M. Assessing severity of asthma with Wright peak-flow meter. Lancet. 1977 Mar 26;1(8013):708–708. doi: 10.1016/s0140-6736(77)92155-9. [DOI] [PubMed] [Google Scholar]
- Nelson S. B., Gardner R. M., Crapo R. O., Jensen R. L. Performance evaluation of contemporary spirometers. Chest. 1990 Feb;97(2):288–297. doi: 10.1378/chest.97.2.288. [DOI] [PubMed] [Google Scholar]
- Pincock A. C., Miller M. R. The effect of temperature on recording spirograms. Am Rev Respir Dis. 1983 Nov;128(5):894–898. doi: 10.1164/arrd.1983.128.5.894. [DOI] [PubMed] [Google Scholar]
- Taplin P. S., Creer T. L. A procedure for using peak expiratory flow rate data to increase the predictability of asthma episodes. J Asthma Res. 1978 Oct;16(1):15–19. doi: 10.3109/02770907809106608. [DOI] [PubMed] [Google Scholar]
- Turney S. Z., Blumenfeld W. Heated Fleisch pneumotachometer: a calibration procedure. J Appl Physiol. 1973 Jan;34(1):117–121. doi: 10.1152/jappl.1973.34.1.117. [DOI] [PubMed] [Google Scholar]