Blood–brain barrier water exchange measurements using contrast‐enhanced ASL

Elizabeth Powell 1,, Ben R Dickie 2,3, Yolanda Ohene 3,4, Mark Maskery 5, Geoff J M Parker 1,6,7, Laura M Parkes 3,4
PMCID: PMC10909569  PMID: 37666494

Abstract

A technique for quantifying regional blood–brain barrier (BBB) water exchange rates using contrast‐enhanced arterial spin labelling (CE‐ASL) is presented and evaluated in simulations and in vivo. The two‐compartment ASL model describes the water exchange rate from blood to tissue, kb, but to estimate kb in practice it is necessary to separate the intra‐ and extravascular signals. This is challenging in standard ASL data owing to the small difference in T1 values. Here, a gadolinium‐based contrast agent is used to increase this T1 difference and enable the signal components to be disentangled. The optimal post‐contrast blood T1 ( T1,bpost) at 3 T was determined in a sensitivity analysis, and the accuracy and precision of the method quantified using Monte Carlo simulations. Proof‐of‐concept data were acquired in six healthy volunteers (five female, age range 24–46 years). The sensitivity analysis identified the optimal T1,bpost at 3 T as 0.8 s. Simulations showed that kb could be estimated in individual cortical regions with a relative error ϵ<1% and coefficient of variation CoV=30%; however, a high dependence on blood T1 was also observed. In volunteer data, mean parameter values in grey matter were: arterial transit time tA=1.15±0.49 s, cerebral blood flow f=58.0±14.3 mL blood/min/100 mL tissue and water exchange rate kb=2.32±2.49 s−1. CE‐ASL can provide regional BBB water exchange rate estimates; however, the clinical utility of the technique is dependent on the achievable accuracy of measured T1 values.

Keywords: arterial spin labelling, blood–brain barrier, gadolinium‐based contrast agent, permeability, water exchange


A technique for quantifying regional blood–brain barrier (BBB) water exchange rates, kb, using contrast‐enhanced arterial spin labelling (CE‐ASL) is presented, and evaluated in simulations and in vivo. Simulations quantified the optimally reduced blood T1 after contrast, as well as the expected accuracy and precision of kb values measured using CE‐ASL. Proof‐of‐concept data in vivo provided plausible kb estimates; however, values were dependent on the accuracy of measured T1 values.

graphic file with name NBM-36-e5009-g009.jpg


Abbreviations

ASL

arterial spin labelling

ATT

arterial transit time

BBB

blood–brain barrier

CASL

continuous arterial spin labelling

CBF

cerebral blood flow

CE‐ASL

contrast‐enhanced arterial spin labelling

CoV

coefficient of variation

CSF

cerebrospinal fluid

DCE

dynamic contrast enhanced

GBCA

gadolinium‐based contrast agent

GM

grey matter

IQR

interquartile range

LD

labelling duration

NEX

number of excitations

PLD

post‐labelling delay

SPGR

spoiled gradient recalled echo

VIF

vascular input function

WM

white matter

1. INTRODUCTION

The blood–brain barrier (BBB) plays a vital role in regulating and maintaining healthy brain function. Passive diffusion of solutes and potential neurotoxins from the blood into the brain is tightly restricted, with the transport of necessary metabolites controlled by specialized proteins. Loss of BBB integrity is increasingly indicated in many neurological conditions, including neurodegeneration, 1 , 2 , 3 , 4 stroke 5 , 6 and multiple sclerosis, 7 , 8 as well as more generally in ageing. 9 , 10 , 11 Dynamic contrast‐enhanced (DCE) MRI is, at present, the most established MRI method for measuring BBB permeability. When the BBB is damaged, leakage of gadolinium‐based contrast agents (GBCAs) from blood to brain tissue provides a measurable post‐contrast T1 enhancement. However, DCE‐MRI is challenging when BBB damage is subtle, as leakage of GBCAs is slow due to the relatively large size of the chelates. Artefacts intrinsic to the method (such as aliasing, signal drift, Gibbs ringing and motion), which can be tolerated when leakage is high, become a limiting factor in detecting the subsequently smaller signal intensity changes for low levels of leakage. 12

Trans‐BBB water exchange is an alternative MRI‐based biomarker for BBB integrity that has the potential for increased sensitivity to subtle damage. 13 Several methods have been developed for measuring trans‐BBB water exchange. While some methods have utilized differences in the T1 relaxation time 3 , 4 , 14 or intrinsic diffusion properties 15 , 16 , 17 of the blood water directly, many adopt an arterial spin labelling (ASL) approach. Proposed ASL techniques have aimed to separate the intra‐ and extravascular signals using diffusion 18 , 19 , 20 or magnetization transfer 21 effects, T2 properties 11 , 22 , 23 , 24 , 25 or velocity encoding. 26 , 27 ASL data generally suffer from low SNR, which is addressed by the existing methods in a variety of ways; as such, current techniques are variably limited by long scan times, aggressive smoothing or a lack of regional exchange rate estimates (a comprehensive overview of the different techniques is provided in Reference 13 ).

ASL‐based methods utilizing T1 differences to separate the intra‐ and extravascular signals are a potential alternative to the above approaches, and preliminary works manipulating the intravascular T1 using a GBCA 5 , 28 , 29 , 30 have shown promise. In the absence of GBCAs, measurements of water exchange using this approach are imprecise owing to the small difference in T1 relaxation times between compartments relative to the exchange rate, 31 requiring SNR levels in excess of clinically attainable values. 32 ASL data acquired under the influence of an intravascular GBCA benefit from a larger difference between the intra‐ and extravascular T1, which should therefore enable the label location to be determined at lower SNR levels. This technique could be a valuable addition to DCE‐MRI studies in cases where minor BBB damage results in minimal GBCA uptake in tissues, providing complementary information on subtle damage via measurements of water exchange.

Contrast‐enhanced (CE) ASL is presented here as a technique for quantifying BBB water exchange, building on previous preliminary data. 29 , 30 Simulations are used first to determine the optimal post‐contrast blood T1, and then to evaluate the expected accuracy and precision of parameter estimates. Proof of concept is then demonstrated in six healthy volunteers.

2. THEORY

The two‐compartment water exchange model 31 for continuous arterial spin labelling (CASL) describes the imaging voxel in terms of a blood water compartment and an extravascular tissue water compartment, each with corresponding volumes ( vbw, vew) and relaxation times ( T1,b, T1,e). Following labelling, tagged blood water arrives at the voxel at arterial transit time (ATT) tA, with a cerebral blood flow (CBF) rate f. Labelled water remains in the intravascular compartment for a finite duration before exchanging into the extravascular compartment. Figure 1A shows a schematic diagram of the compartmental model.

FIGURE 1.

FIGURE 1

ASL signal model. (A) Schematic diagram of the two‐compartment exchange model. The blood water compartment (red) and extravascular tissue water compartment (blue) have volumes vbw, vew and relaxation times T1,b, T1,e respectively. Exchange occurs at the rate kb; cerebral blood flow is indicated by f. (B) Simulated ASL difference signal ΔM for the two‐compartment CASL model in Equation (4) for the equilibrium pre‐contrast T1,b (solid lines) and for a range of post‐contrast T1,b values (dashed lines). Fixed parameters: exchange rate kb=2.65 s−1 (black/gray lines), extravascular relaxation time T1,e=1.5 s, cerebral blood flow f=60 mL blood/ min /100 mL tissue, label duration tL=2 s, arterial transit time tA=1.2 s, brain:blood partition coefficient  λ=0.9 and inversion efficiency  α=0.85. The red/blue lines correspond to signals with kb increased/decreased by 50%, respectively (i.e., kb=3.98,1.33 s−1)

Evolution of each compartment's magnetization in the ASL difference image (control − label) is given by

dvbwΔmbtdt=vbwΔmbtT1,b+fΔmatfΔmvt+PSΔmetΔmbt (1)
dvewΔmetdt=vewΔmetT1,e+PSΔmbtΔmet (2)

where PS is the permeability ( P) surface area ( S) product describing exchange between compartments, Δmb and Δme represent the magnetization of capillary blood water and extravascular water within the tissue voxel, and Δma and Δmv represent the magnetization of arterial blood water and venous blood water arriving at and leaving from the tissue voxel respectively. The total ASL difference signal is modelled as the sum of the intra‐ and extravascular difference magnetizations weighted by their relative volumes:

ΔMt=vbwΔmbt+vewΔmet. (3)

Implicit in Equations (1) and  (2) is the assumption that labelled blood resides in exchanging vessels (capillaries and arterioles) only, meaning that contributions from larger vessels (arteries) are excluded; this is generally expected to be valid for post‐labelling delay (PLD) times greater than 1 s. Further assumptions can be made to simplify the solutions under certain conditions. 31 First, for perfusion rates in normal human brain tissue, it can be assumed that the label will have decayed (due to T1 recovery) before entering the venous circulation, meaning there is no outflow of labelled blood from the voxel during the PLD and so the venous component can be excluded (i.e., Δmv=0). Second, effects of backflow on the signal—that is, exchange of labelled magnetization from the extravascular space back into the blood—can also be neglected under the assumption that at all times the proportion of labelled extravascular spins is much less than the proportion of labelled intravascular spins (i.e., ΔmeΔmb, giving PSΔme=0).

Under these assumptions, as derived in earlier work, 31 the time‐dependent solutions to Equations (1) and  (2) are

ΔMt=0,t<tA2fma0αexpR1,btA1expJtJ+kbJR1,e+R1,eexpJtJexpR1,etJR1,eJR1,e,tAttA+tL2fma0αexpR1,btA1J+kbJR1,eJexpJtL1expJtkbexpR1,etR1,eR1,eJexpR1,etL1,t>tA+tL (4)

where t is the time from the start of labelling, tL is the labelling duration (LD), ma0=M0/λ is the equilibrium arterial magnetization with M0 the equilibrium magnetization and λ the brain:blood partition coefficient, α is the inversion efficiency of the labelling, R1,b=1T1,b and R1,e=1T1,e are the relaxation rates of the blood and tissue compartments, J=kb+R1,b where the exchange rate of labelled water from blood to tissue is kb=PS/υbw and t=ttA. Table 1 gives a full definition of all parameters.

TABLE 1.

Parameter definitions, abbreviations and units.

Parameter Definition Unit
T1,bpre
longitudinal relaxation time of blood pre‐contrast s
T1,bpost
longitudinal relaxation time of blood post‐contrast s
T1,e
longitudinal relaxation time of GM extravascular space s
f
cerebral blood flow (CBF) mL blood/min/100 mL tissue
tA
arterial transit time (ATT) s
PS
permeability surface area product to water mL water/min/mL tissue
vbw
blood water volume fraction mL water/mL tissue
vew
extravascular water volume fraction mL water/mL tissue
kb
kb=PS/υbw
s−1
tL
label duration (LD) s
λ
brain:blood partition coefficient mL/g
α
inversion efficiency of labelling a.u.
M0
equilibrium magnetization magnetic moment/mL tissue
ma0
equilibrium arterial magnetization magnetic moment/mL blood
mb
intravascular magnetization magnetic moment/mL water
me
extravascular magnetization magnetic moment/mL water

Longitudinal relaxation during the ATT as the labelled blood water arrives at the imaging slice reduces the magnetization difference Δmbt according to Equation (1). Under the influence of an intravascular GBCA, the shorter blood water T1 causes Δmbt to reduce more rapidly; this allows the presence of magnetization that has permeated into the extravascular space (which now has a substantially longer T1 relative to blood) to have a greater influence on the total difference magnetization ΔMt. Figure 1B displays numerical simulations that illustrate the expected ΔMt. With knowledge of the blood and tissue T1 before and after GBCA contrast injection, Equations (1) and (2) allow these different ΔMt to be modelled to extract estimates of the exchange rate. However, as is evident in Figure 1B, higher GBCA concentrations also reduce the overall ΔMt, leading to worsened contrast‐to‐noise ratio. This trade‐off is explored here to identify the optimal conditions for contrast‐enhanced arterial spin labelling (CE‐ASL) estimates of BBB water exchange.

3. METHODS

Four simulation experiments were performed to assess the feasibility of the CE‐ASL method and inform acquisition parameters in vivo. The sensitivity of the CE‐ASL signal to water exchange was first evaluated to identify optimal post‐contrast blood water T1 ( T1,bpost) and PLD times at 3 T. Under these optimal conditions, the impact of inaccurate relaxation time values on parameter estimates was explored in an error analysis. Monte Carlo simulations under varying noise conditions then provided an estimate of the expected accuracy and precision of fitted parameters. Finally, the GBCA dose and time after injection required to obtain optimal T1,bpost values in vivo were calculated using data from a previous study. Based on the simulation results, an in vivo protocol was designed and conducted in six healthy volunteers. All simulations were performed in MATLAB R2019b (The MathWorks Inc., Natick, Massachusetts).

3.1. Sensitivity analysis

The sensitivity functions were defined as the partial derivatives of the signal model in Equation (4) with respect to kb (provided in full in Appendix A).

To determine optimal T1,bpost and PLD times, the sensitivity functions were computed for parameter combinations in the ranges 0.15sT1,bpost1.65s  and 0.5sPLD3.0s , with T1,b=1.65 s taken as the non‐contrast‐enhanced value in blood at 3 T. 33 The exchange rate was fixed at kb=2.65 s−1, the mean of several published studies. 13 Calculated sensitivities were normalized using the maximum value obtained across the range of parameter combinations; optimal T1,bpost and PLD times were taken as those that maximized the sensitivity functions.

As the modelling approach assumes that the GBCA remains intravascular, the impact of extravasated contrast agent on sensitivity to kb was assessed by varying T1,e from its non‐contrast‐enhanced value at 1.5 s 34 , 35 down to the optimally reduced T1,bpost, thereby mimicking GBCA leakage into tissue and the subsequent reduction of T1,e. For completeness, this range of T1,e values encompasses the spectrum of exchange rates from no exchange (i.e., T1,e=1.5 s) to infinite exchange (i.e., T1,e=T1,bpost s); however, only small reductions are expected for subtle BBB damage. The T1,bpost and PLD times were fixed to their optimized values.

Finally, variation of the sensitivity in relation to underlying exchange rate was explored for 0.5kb4.0 s−1, which is representative of previously reported values in human grey matter (GM), 13 over the range 0.15T1,bpost1.65 s.

All other model parameters used in each simulation are provided in Table 2.

TABLE 2.

For all simulations, other fixed parameters were cerebral blood flow f=60 mL blood/min/100 mL tissue, 32 label duration tL=2 s, arterial transit time tA=1.2 s 33 (note that this is variable in vivo depending on labelling location and brain region), brain:blood partition coefficient  λ=0.9 33 and inversion efficiency α=0.85. 33

T1,bpre [s] T1,bpost [s] T1,e [s] kb [s−1] PLD [s]
Sensitivity analysis
‐ optimal T1,bpost & PLD 0.15–1.65 1.5 2.65 0.5–3.0
‐ extravasated Gd ( T1,e) 0.80 0.8–1.5 2.65 1.5
‐ underlying kb 0.15–1.65 1.5 0.5–4.0 1.5
Error propagation
T1,bpre errors
1.65±15%
0.8 1.5 2.65 pre‐contrast: 0.9,
T1,bpost errors 1.65
0.8±15%
1.5 2.65 1.2, 1.5, 1.8, 2.1;
T1,e errors 1.65 0.8
1.5±15%
2.65 post‐contrast: 1.5
pre‐contrast: 0.9,
Accuracy and precision 1.65 0.8 1.5 0.5–4.0 1.2, 1.5, 1.8, 2.1;
post‐contrast: 1.5

3.2. Error propagation

Systematic biases in parameter estimates arising from T1 measurement errors were evaluated using numerical simulations. Noise‐free synthetic signals were generated using Equation (4) for five PLD times between 0.9 and 2.1 s with T1,b set at the equilibrium (pre‐contrast) value and for one PLD of 1.5 s with T1,b set at the optimally reduced (post‐contrast) value. Table 2 provides all model parameters. The signal model was then fitted back to the data using perturbations from ground truth T1 values of ±15%. Fitting was performed using least‐squares minimization with f, tA and kb as the free parameters, initialized using 100 starting values and constrained to 0f200 mL blood/min/100 mL tissue, 0tA2.5 s and 0kb5 s−1. Starting values were randomly distributed between parameter bounds. Resulting errors in f, tA and kb were quantified using the percentage relative error ϵ=100×xfitxgt/xgt, where xfit and xgt represent the fitted and ground truth value of a given parameter respectively.

3.3. Accuracy and precision

The accuracy and precision of fitted parameters were estimated using Monte Carlo simulations under varying noise conditions. Data were simulated before and after contrast (as described for the error propagation) for 25 kb values between 0.5 and 4.0 s−1; details of other parameters are in Table 2. For each parameter combination, 2500 control and label signals were synthesized. Zero‐mean Gaussian noise with standard deviations σ=0.0033,0.0017,0.0011 was added to the control and labelled data independently, giving voxel‐wise SNRs of 15, 30, 45 in background‐suppressed control data 36 (signal taken as 5% of the equilibrium magnetization, assuming 95% background suppression efficiency), before pairwise subtraction to create the difference signal. Corresponding voxel‐wise SNRs in the difference signal were 1.8, 3.6, 5.4. Voxel‐level SNR values were increased by N to simulate the higher SNR at regional levels, with N=500 taken as the approximate number of voxels in a cortical region of interest (ROI). All T1 values were fixed to their ground truth for fitting (performed as for the error propagation). The accuracy of parameter estimates was assessed using the relative error between the ground truth and median fitted values; precision was quantified using the coefficient of variation (CoV), defined as the interquartile range (IQR) of fitted values normalized by the ground truth value. Extreme parameter fits within 5% of the fit constraints ( 0kb10 s−1) were discarded from these calculations.

To assess the feasibility of kb estimates at different regional levels, voxel‐wise SNR values were adjusted for signal averaging across ROI sizes equivalent to whole lobes ( N=10000) down to the voxel level ( N=1) for a single fixed kb=2.65 s−1 (fitting constrained to 0kb5 s−1).

3.4. Optimal injected GBCA dose

The GBCA dose needed to achieve the optimal T1,bpost was investigated as a function of injected dose and time post‐injection. Volunteer DCE‐MRI data were taken from a previous study of 31 healthy volunteers (mean age 66 years, range 52–81 years) 37 ; briefly, the data comprised pre‐contrast T1‐weighted images acquired at three different flip angles, and a dynamic series of single flip angle acquisitions following 0.1 mmol/kg injection of Dotarem GBCA collected every 7.6 s up to 20 min after injection. These data were used to calculate the pre‐ and post‐contrast blood T1 values ( T1,bpre and T1,bpostt, respectively); full details can be found in the Supplementary Material of Reference. 37

The mean vascular input function (VIF)—or blood concentration, cbt—over time was calculated using

R1,bpostt=R1,bpre+r1cbt, (5)

with R1,bpostt=1/T1,bpostt the blood relaxation rate at each time point t after contrast, R1,bpre=1/T1,bpre=0.61 s−1 the blood relaxation rate before contrast and r1=3.4 s−1mM−1 the GBCA longitudinal relaxation coefficient. 38

The cb estimates were then scaled to 0.25, 0.50 and 0.75 of the value at the full GBCA dose to simulate R1,bpost variation at different dose levels. This provided an estimate of the appropriate dose and time after injection for the optimal T1,bpost.

All blood T1,bpost curves were extrapolated using the functional form of the VIF—as described in Reference 39 —to 250 min to show the full T1 recovery to its equilibrium (pre‐contrast) value.

3.5. MRI acquisition

Proof‐of‐concept data were acquired in six healthy volunteers (five female, mean age 30 years, range 24–46 years) on a simultaneous 3 T SIGNA PET‐MR scanner (GE Healthcare, Chicago, Illinois); ethics approval was granted by the University of Manchester Research Ethics Committee (reference: 2021‐5795‐18124).

A 3D T1‐weighted magnetization prepared rapid acquisition gradient echo (MPRAGE) image was acquired prior to contrast agent injection with 1 mm3 isotropic resolution for segmentation of GM, white matter (WM) and cerebrospinal fluid (CSF).

ASL data and additional T1 maps were collected before and after contrast agent injection (Figure 2). Two low‐dose injections of a GBCA (Dotarem) were administered—each a quarter dose (0.025 mmol/kg), providing 0.050 mmol/kg of Dotarem total—in order to capture the optimal T1 reduction. Each post‐contrast data set (referred to as PC1 and PC2 respectively) was analysed independently.

FIGURE 2.

FIGURE 2

Acquisition pipeline. ASL data (including proton density images acquired with each PLD, indicated by the white dashed lines) and T1 maps were acquired pre‐contrast and again following two low‐dose gadolinium injections. A B1 map was also collected pre‐contrast.

ASL was performed with pseudo‐continuous labelling (pCASL), background suppression (all PLDs), no vascular crushing gradients, 33 a 3D spiral fast spin echo readout with eight spiral interleaves (512 sampling points, giving a spiral readout duration of 475 ms), voxel size 1.7×1.7×4 mm3 with 36 axial slices covering the complete brain (lowest slice positioned at the base of the cerebellum), TE=11 ms, minimum TR set according to PLD and RF duration/gap of 0.5/1.5 ms. The labelling plane was positioned 2 cm inferior and parallel to the 3D acquisition box. Data at six PLDs (0.7, 0.9, 1.2, 1.5, 1.8 and 2.1 s) were collected before contrast agent injection (the PLD at 0.7 s was not collected in two subjects), with LD 2 s and two repeats (number of excitations, NEX). An additional proton density image was acquired with each PLD. The total pre‐contrast pCASL acquisition time was 15 min. Post‐contrast ASL data were collected approximately 7 min after each contrast agent injection at a single PLD of 1.5 s with NEX=5. One PLD was used to allow time to increase the NEX in comparison to the pre‐contrast acquisition and compensate for the expected signal reduction. The acquisition time of each post‐contrast data set was 6 min.

To produce T1 maps before and after contrast, 3D T1‐weighted spoiled gradient recalled echo (SPGR) images were acquired using four flip angles (2°, 5°, 15° and 20°), with voxel size 2×2×4 mm3, TR/TE=4.75/1.06 ms and NEX=8. Acquisition of the four different flip angle images was repeated approximately 3 min after each contrast agent injection, prior to the ASL acquisition. Each flip angle acquisition was 1 min. A 2D Bloch‐Siegert B1 map was also collected before contrast with flip angle 10°, field of view matched to the T1 map and resolution 3×3×8 mm3.

3.6. MRI analysis

3.6.1. Extraction of regional ASL and tissue T1values

The ASL subtraction images were divided by the ASL proton density images on a voxel‐wise basis. The 3D T1‐weighted image was segmented into GM, WM and CSF using SPM12. 40 Pre‐ and post‐contrast T1 maps and the ASL proton density image were co‐registered to the 3D T1‐weighted image, and the transformation used to propagate the ASL subtraction images into the same space. The T1‐weighted image was then registered to the MNI template, and the transformation applied to the GM and CSF probability maps from the segmentation and the co‐registered T1 maps and ASL subtraction images. The automatic anatomical labelling atlas 41 (masked for GM) was used to extract the mean ASL subtraction signal and T1 estimates from the 90 cortical and sub‐cortical regions (excluding the cerebellum).

3.6.2. Estimation of blood T1

Pre‐ and post‐contrast T1 maps were estimated by fitting the SPGR signal model to the four flip angles at each contrast level. 42 This was done in R (version 4.2) using the Levenberg–Marquardt optimization solver. Each post‐contrast T1 map (in MNI space) was subtracted from the pre‐contrast map to produce two subtraction images, one for each contrast agent dose. On each subtraction image a region in the sagittal sinus and straight sinus was identified using the ROI tool in MRIcro. 43 The region was masked to contain only those voxels with at least a 20% reduction in T1 following contrast agent injection, effectively identifying the voxels with the highest blood volume, to produce the final blood ROI (see Supporting Information, Figure S1). The 75th percentile T1 value within the blood ROI on the pre‐contrast T1 map was recorded as the T1,bpre value, chosen as it probably contains high blood volume but will be less affected by noise than the maximum value. The T1,bpost value was estimated by subtracting the pre–post T1 difference (again taken as the 75th percentile value within the blood ROI on the subtraction image) from the T1,bpre value. This process was repeated independently for each subtraction image.

3.6.3. Kinetic modelling of ASL data

Equation (4) was fitted to the data on a voxel‐wise basis in MATLAB 2021a using an unconstrained simplex search method with initial values f=60 mL blood/min/100 mL tissue, tA=1.0 s, kb=1 s−1. Voxel‐wise T1,e values and global T1,b values were fixed to their measured values before and after contrast, with α=0.85, λ=0.9, tL=2 s and M0 measured from the proton density images. Regional parameter estimates were obtained by taking the median of voxel‐wise values within an ROI.

3.6.4. SNR estimation

No independent noise measurement was available for the in vivo data, so voxel‐level SNR was approximated within each ROI (after averaging signal repetitions) as

SNRvox=x¯σ (6)

where x¯ and σ are the signal mean and standard deviation within an ROI in the ASL difference image at PLD=1.5 s.

4. RESULTS

4.1. Sensitivity analysis

Figure 3A shows that the model was most sensitive to kb for T1,b=0.8 s and PLD=1.5 s (normalized sensitivity value of 1). These optimal values provided a more than threefold increase in sensitivity compared with the use of no contrast (equivalent to T1,b=1.65 s; normalized sensitivity value of −0.3). Sensitivity remained within 90% of the maximum value over the ranges 0.6T1,b1.0 s and 1.3PLD1.9 s. Minimal sensitivity (under 10% of the maximum value) was observed both for very short T1,b values ( T1,b0.3 s) and for T1,bT1,e.

FIGURE 3.

FIGURE 3

Sensitivity analyses. (A) Sensitivity of the ASL difference signal to the exchange rate,  kb, as a function of blood T1,b and post label delay (PLD) time (with extravascular T1,e=1.5 s and kb=2.65 s−1). The colour bar shows the magnitude of the sensitivity functions, which were normalized using the maximum value obtained over the range of parameter combinations (indicated by the black cross). (B) Sensitivity dependence on T1,e, simulating the effect of extravasated contrast agent (with T1,b=0.8 s, PLD=1.5 s, kb=2.65 s−1). The black line indicates the potential T1,e after leakage from minor blood‐brain barrier damage in vivo. (C) Sensitivity dependence on underlying kb values (with T1,b=0.8 s, T1,e=1.5 s, PLD=1.5 s). All sensitivity functions were normalized to the parameter set consisting of kb=2.65 s−1, T1,b=0.8 s, T1,e=1.5 s and PLD=1.5 s (indicated in each panel by the black cross). Other model parameter details are given in Table 2.

Reductions in T1,e arising from extravasated contrast agent corresponded to an approximately linear decrease in sensitivity, culminating in zero sensitivity to kb for T1,e=T1,b (Figure 3B). This represents the full range of BBB integrity, from fully intact with no leakage of the GBCA (i.e., T1,e=1.5 s, the equilibrium value) to unobstructed leakage (i.e., T1,e=T1,b). A reduction of 0.1 s may be expected for minor BBB damage, 37 corresponding to a decrease in sensitivity of 10%.

Figure 3C shows the sensitivity dependence of the model to underlying kb values. Greater sensitivity was observed for lower exchange rates. From the magnitude of the sensitivity function—which provides an indication of the expected level of measurement precision for a given noise level—it can be seen that, compared with a baseline kb=2.65 s−1, an increase of 15% in the exchange rate to kb=2.92 s−1 would correspond to a 12% reduction in measurement precision. The optimal T1,b varied minimally from T1,b=0.77 s at the highest exchange rate ( kb=4.0 s−1) to T1,b=0.86 s at the slowest exchange rate ( kb=0.5 s−1).

4.2. Error propagation

Figure 4 shows the errors propagated into kb, f and tA by errors in measured T1 values. The accuracy of kb was highly sensitive to errors in both T1,bpre and T1,bpost: to obtain estimates of kb with less than 10% error required T1,bpre to be known within ±1.5% and T1,bpost within ±0.7%. Errors in T1,e propagated less uncertainty into kb estimates, requiring a measurement accuracy of ±11% to maintain the same 10% error level in kb.

FIGURE 4.

FIGURE 4

Error propagation. (A) Error propagated into the exchange rate, kb, from errors in each measured T1 value (blood pre‐contrast, T1,bpre; blood post‐contrast, T1,bpost; extravascular, T1,e). (B) Error propagated into the cerebral blood flow, f, from errors in each T1 value. (C) Error propagated into the arterial transit time, tA, from errors in each T1 value. Ground truth parameter values (all figures): kb=2.65 s−1, f=60 mL blood/min/100 mL tissue, tA=1.2 s, T1,bpre=1.65 s, T1,bpost=0.8 s, T1,e=1.5 s (full details in Table 2)

CBF accuracy was more influenced by errors in T1,bpre and T1,e than in T1,bpost. To estimate f with under 10% error required a measurement accuracy within ±9.1% for T1,bpre and within ±14.4% for T1,e. The CBF error was under 5% for all simulated T1,bpost errors ( ±15%).

The error propagated into ATT estimates was under 5% for all simulated T1 errors ( ±15%).

4.3. Accuracy and precision

The variation in accuracy and precision of fitted model parameters with underlying kb values is shown in Figure 5A–C. No biases were evident in any of the kb estimates; however, precision, indicated by the shaded error bars (IQR of fitted values), was reduced at higher kb values, as predicted by the sensitivity analysis in Figure 3C. The accuracy and precision of the CBF and ATT were largely unaffected by underlying exchange rates. The number of extreme fits was under 6% in all cases (see Supporting Information, Figure S2).

FIGURE 5.

FIGURE 5

Accuracy and precision. (A–C) Median parameter values (solid lines) for a simulated cortical ROI (500 voxels) as a function of ground truth exchange rates in the range 0.5kb4.0 s−1 for the fitted exchange rate, kb (A), cerebral blood flow, f (B) and arterial transit time tA (C). Shaded regions indicate the IQR of fitted values; black dashed lines indicate ground truth parameter values. (D–F) Relative errors in parameter estimates (for fixed kb=2.65 s−1) after signal averaging across different simulated ROI sizes for kb (D), f (E) and tA (F). (G–I) The coefficient of variation (CoV) of parameter estimates (for fixed kb=2.65 s−1) after signal averaging across different simulated ROI sizes for kb (G), f (H) and tA (I). In all figures, displayed SNR levels indicate voxel‐wise values in the control signal. Full simulation details are in Table 2.

The feasibility of regional water exchange measurements is considered in Figure 5D–I. Given a voxel‐wise SNR of 30 in the control signal (and fixed kb=2.65 s−1), in a cortical ROI (500 voxels) the relative error of kb was under 1% and the CoV was 30%. Signal averaging across a simulated lobe (10 000 voxels) reduced the CoV to 7%. The CoV of voxel‐level kb estimates was very high (190%). CBF and ATT were estimated with good accuracy (relative error ϵ<1%) and reasonable precision ( CoVf<21% and CoVtA<38%) at the voxel level for SNR=30.

4.4. Optimal injected GBCA dose

Figure 6 shows the recovery of T1,bpost with time after contrast agent injection. Optimal values of T1,bpost=0.8 s were obtained approximately 3 min after injection of a 0.025 mmol/kg dose (quarter dose), 21 min after a 0.050 mmol/kg dose (half dose), 37 min after a 0.075 mmol/kg dose (three‐quarter dose) and 48 min after a 0.100 mmol/kg dose (full dose).

FIGURE 6.

FIGURE 6

Optimal injected GBCA dose. Calculated blood T1,b recovery curves post‐contrast are shown for different GBCA dose levels; a standard full dose is 0.100 mmol/kg. Dotted lines indicate the time after injection to reach the optimal T1,bpost=0.8 s, highlighted for each dose level by the circles. Yellow markers indicate the experimental data from Reference 37 .

4.5. In vivo data

The mean and standard deviation across subjects of GM T1 values were: (i) T1,e=1.50±0.09 s pre‐contrast; (ii) T1,e=1.48±0.09 s for PC1, and; (iii) T1,e=1.39±0.09 s for PC2. Representative tissue T1 maps pre‐ and post‐contrast, along with example ASL subtraction images pre‐ and post‐contrast, are provided in the Supporting Information, Figure S3. Pre‐ and post‐contrast blood T1,b values were: (i) T1,bpre=1.87 ±0.06 s and T1,bpost=1.14±0.11 s for PC1, and; (ii) T1,bpre=1.83 ±0.06 s and T1,bpost=0.91±0.04 s for PC2.

As the PC2 T1,bpost best approximated the optimal value, results from the PC2 data set will primarily be presented from here on; results from the PC1 data can be found in the Supporting Information (Figure S4.1 and Table S4.2).

Figure 7 shows regional parameter maps derived from the PC2 data for all six subjects.

FIGURE 7.

FIGURE 7

ASL regional parameter maps (PC2). (A) Exchange rate, kb. (B) Arterial transit time,  tA. (C) Cerebral blood flow,  f. All parameter values derived from the second post‐contrast data set, PC2. In all maps, black voxels represent masked white matter and CSF, as well as extreme kb fits (i.e., kb<0 s−1 or kb>10 s−1). Parameter values averaged over the ROIs ( k¯, t¯A, f¯) are displayed for each volunteer.

Mean regional parameter estimates for a selection of 18 cortical and sub‐cortical regions (of particular relevance to dementia) are provided in Figure 8; results from all 90 regions can be found in the Supporting Information, Table S5. Good left/right hemispheric correspondence was observed in the exchange rate maps, although a few extreme fits ( kb<0 s−1 or kb>10 s−1) were noted in Subjects 1 and 2. Data for these subjects were acquired without the shortest PLD ( PLD=0.7 s), so fit instabilities may have arisen owing to the reduced number of data points. Averaged across subjects, the means and standard deviations of parameter values were tA=1.15±0.49 s, f=58.0±14.3 mL blood/min/100 mL tissue, kb=2.32±2.49 s−1.

FIGURE 8.

FIGURE 8

Mean parameter values across subjects in selected regions (PC2). (A) Exchange rate, kb. (B) Arterial transit time,  tA. (C) Cerebral blood flow, f. All parameter values derived from the second post‐contrast data set, PC2. In all subplots, bar height represents the mean and error bars show the standard deviation across subjects.

The mean SNR across segmented regions in the subtraction image at PLD=1.5 s was 3.6 before contrast and 3.1 in the PC2 data (corresponding to SNR30 in the unlabelled data in simulations), indicating that the increased number of averages after contrast compensated well for the expected loss of signal. Good agreement was observed between the data and model fits before and after contrast (see Supporting Information, Figure S6).

5. DISCUSSION

This simulation and proof‐of‐concept study demonstrates that measurements of BBB permeability to water are feasible using CE‐ASL if accurate T1 values can be obtained: under the influence of an intravascular GBCA, the increased difference between blood water and tissue T1 relaxation times enables the signal contribution from intra‐ and extravascular compartments to be distinguished and kb to be estimated.

Identifying the optimal difference between blood water and tissue T1 relaxation times is key to obtaining reliable water exchange estimates using this method owing to the inherent trade‐off between the reduction in T1,bpost and sensitivity to kb (Figure 3C). Marginal reductions in T1,bpost do not sufficiently perturb the post‐contrast signal, meaning that the relative contributions of intra‐ and extravascular compartments remain difficult to separate and sensitivity is correspondingly low. Conversely, extreme reductions in T1,bpost lead to a vanishing difference signal as fast recovery of the labelled spins relative to the ATT negates the effect of the inversion, rendering the post‐contrast signal equivalent to the control data. It was shown using simulations that moderate reductions in T1,bpost best enabled water exchange measurements, and, moreover, that a range of T1,bpost values presented similar capacities to reliably estimate kb. Practically, this allows for flexibility in protocol design, as precise timings of the post‐contrast ASL acquisition relative to GBCA administration—as well as precise administration of the GBCA dose itself—are not critical; however, increasing the number of signal averages for lower T1,bpost values may be prudent as the difference signal will be smaller and more susceptible to noise. Simulations showed that even a quarter dose (0.025 mmol/kg) could provide the optimal T1,bpost (Figure 6), which has reduced safety concerns compared with a full dose.

The sensitivity analysis indicated that more precise kb estimates can be expected at lower exchange rates (Figure 3C), meaning that CE‐ASL is best suited to probing early, subtle damage. Monte Carlo simulations supported this finding and quantified the measurement precision of model parameters in terms of ground truth kb (Figure 5A–C). The accuracy and precision of fitted parameters was also quantified as a function of SNR (Figure 5D–I). CBF and ATT were estimated at the voxel level with acceptable precision at realistic noise levels in synthetic data.

Reliable estimates of kb at the voxel level proved unfeasible in simulations, with a measurement precision approaching CoV190% (Figure 5G): inherently low SNR data combined with low sensitivity of the model to kb (relative to the CBF and ATT) renders kb a challenging parameter to fit. Voxel‐wise fits in vivo (see Supporting Information, Figure S7) corresponded to the simulation predictions, with a number of extreme fits apparent. ROI analyses are valuable in this instance as the SNR effectively increases as the square root of the number of voxels, reducing random measurement errors and making regional kb estimates more reliable (Figure 7A). Practically, it should be noted that an upper limit on the ROI size used for regional analysis is likely to exist owing to variability in ATT, CBF and potentially kb across the brain, particularly in disease.

Regional in vivo kb measurements (Figure 8) were in agreement with literature values. The mean value across all segmented ROIs and subjects was kb=2.32 s−1; previous studies have reported average GM values in the range 0.63–3.68 s−1. 13 There was also good agreement in regional values between hemispheres, suggesting that physiologically plausible kb values can be obtained using CE‐ASL. CBF was notably lower in two subjects, although in line with published values 32 , 44 , 45 and reports of high inter‐subject variability. 46 Age and gender may also explain this finding: one of the two subjects was the only male and one was older, and lower CBF has been reported in both demographics. 47 , 48

There are two limiting factors in the Monte Carlo simulations in this study. First, regional variations in ATT observed in vivo were not modelled in the simulations: regions with tA>1.5 s (i.e., ATT longer than the post‐contrast PLD) are likely to have lower precision as the complete bolus may not have arrived at the voxel at the time of imaging. Post hoc evaluation of the sequence sensitivity and the accuracy and precision of kb estimates confirmed this: while high accuracy was maintained regardless of ATT, longer ATTs incurred lower sensitivity (reduced by approximately 35% at tA=1.5 s compared with tA=1.2 s) and subsequently lower precision (IQR increased by approximately 65% at tA=1.5 s compared with tA=1.2 s) (see Supporting Information, Figure S8). Acquiring data at multiple PLDs post‐contrast may increase sensitivity for regions with longer ATT (or potentially with variations in T1,b, as might occur owing to haematocrit changes in sickle cell disease 49 ) and should be evaluated in future work; a single post‐contrast PLD=1.5 s was chosen here to allow time for multiple signal averages. Second, alterations in T1,e were not modelled in the simulations: contrast agent leakage into the extravascular space acts to decrease the difference between the post‐contrast blood water and tissue T1 times, making the separation of intra‐ and extravascular signal components more challenging. The sensitivity analysis confirmed this, showing that, as T1,epostT1,bpost,kb was estimated with increasingly poorer precision. In our proof‐of‐concept study a reduction of about 7% in tissue T1 was observed; however, as this is the total tissue value and includes the blood component, the reduction in T1,b post‐contrast probably explains the majority of this decrease. Moreover, the decrease was consistent across subjects and so does not suggest leakage due to pathology.

Nonetheless, this is a minor limitation of the technique, and raises the more general point that T1,e is not independent of kb. This was also not modelled in simulations and should be considered in future studies. In the in vivo data, adding vascular crushers to the acquisition may improve estimation of the ATT and CBF: without vascular crushers, the signal at short PLDs may contain contributions from large vessels, leading to shorter ATT and higher CBF; however, as no exchange is expected to occur in large vessels, kb is unlikely to be affected.

The primary limitation of CE‐ASL is the accuracy required in T1 measurements (Figure 4). Similar systematic errors in both T1,bpre and T1,bpost may mitigate error propagation into kb to some extent as opposing effects are introduced (see Supporting Information, Figure S9); however, particularly for T1,bpost, where sensitivity to kb and therefore error propagation is greatest, small errors can introduce significant biases into kb measurements. The potential effect on in vivo parameter estimates arising from T1,b biases was explored post hoc by perturbing the measured T1,bpre and T1,bpost by ±10% and re‐fitting the model (see Supporting Information, Figure S10). Mean fitted parameter values varied according to the trends predicted in Figure S9, with kb increased on average by 100% for T1,b adjusted 10% lower and reduced by 44% for T1,b adjusted 10% higher than the measured value. It must also be considered that inter‐subject variability in T1,b can be introduced depending on haematocrit levels and oxygen extraction fraction, 50 which further emphasizes the need for reliable individual T1,b mapping; however, regional kb variations within a subject may still be identified. Finally, clinical conditions in which key assumptions of the model are violated—for example arteriovenous malformations, where the passage of blood into the microvasculature is disrupted and the assumption of no outflow no longer holds—must be treated cautiously.

Given current clinical capabilities, these T1 accuracy requirements limit the utility of the CE‐ASL technique at this point. Assuming a situation where T1 values are accurate enough, a clinically practical application of CE‐ASL would be in conjunction with conventional DCE‐MRI studies: ASL data acquired before and after a DCE‐MRI protocol could utilize the residual effects of the GBCA to obtain the optimally shortened T1,bpost needed for CE‐ASL imaging, and dose calculations suggest that the time to optimal T1,bpost following a full‐dose injection could make this approach feasible (32 min to reach the lower bound T1,bpost=0.6 s). In cases where BBB damage is minor and DCE‐MRI does not show significant uptake of the contrast agent in the tissue, 3 concomitant acquisition of CE‐ASL data could provide a complementary indication of subtle BBB breakdown. However, it is necessary to reduce the dependence of kb estimates on measured T1 values for this to be clinically viable.

Supporting information

nbm5009‐sup‐0001‐Supporting Information.pdf

ACKNOWLEDGMENTS

This work was supported by EPSRC grants EP/S031510/1 and EP/M005909/1. Research funding for scans was provided by GE HealthCare.

SENSITIVITY FUNCTIONS

1.

The sensitivity functions are defined as the partial derivative of the signal model with respect to kb. The shape and magnitude of the functions therefore indicate the sensitivity of the signal model to changes in kb; the sign of the functions indicates whether a change in kb induces an increase or decrease in signal intensity. The sensitivity functions for the CASL model in Equation (4) are

ΔMtkb=0t<tAafexpR1,btAtexpJtJ1expJtJ2+J1expR1,etR1,e1expJtJR1,eJR1,ekbJ1expR1,etkbR1,e1expJtJR1,eJR1,e2kbJ1expR1,etkbR1,e1expJtJ2R1,eJR1,ekbexpR1,et+R1,etexpJt1JR1,eJR1,etAttA+tLafexpR1,btAexpJtexpJtL11J2+1JJR1,ekbJJR1,e2kbJ2JR1,etLexpJtLexpJt1JkbJJR1,e+texpJtexpJtL11JkbJJR1,eexpR1,etexpR1,etL1R1,eJR1,e+kbexpR1,etexpR1,etL1R1,eJR1,e2t>tA+tL. (A1)

where tL is the labelling time, tA is the arterial transit time, f is the cerebral blood flow, α is the inversion efficiency of the labelling, R1,e=1/T1,e, R1,b=1/T1,b, J=kb+R1,b and t=ttA.

Powell E, Dickie BR, Ohene Y, Maskery M, Parker GJM, Parkes LM. Blood–brain barrier water exchange measurements using contrast‐enhanced ASL. NMR in Biomedicine. 2023;36(11):e5009. doi: 10.1002/nbm.5009

*

Geoff J. M. Parker and Laura M. Parkes These authors contributed equally to this work.

DATA AVAILABILITY STATEMENT

The data that support the findings of this study are available on request from the corresponding author. The data are not publicly available due to privacy or ethical restrictions.

REFERENCES

  • 1. van de Haar HJ, Burgmans S, Jansen JFA, van Osch MJP, van Buchem MA, Muller M, Hofman PAM, Verhey FRJ, Backes WH. Blood–brain barrier leakage in patients with early Alzheimer disease. Radiology. 2016;281(2):527‐535. [DOI] [PubMed] [Google Scholar]
  • 2. Sweeney MD, Sagare AP, Zlokovic BV. Blood–brain barrier breakdown in Alzheimer disease and other neurodegenerative disorders. Nat Rev Neurol. 2018;14(3):133‐150. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3. Dickie BR, Vandesquille M, Ulloa J, Boutin H, Parkes LM, Parker GJM. Water‐exchange MRI detects subtle blood–brain barrier breakdown in Alzheimer's disease rats. NeuroImage. 2019;184(May 2018):349‐358. [DOI] [PubMed] [Google Scholar]
  • 4. Dickie BR, Boutin H, Parker GJM, Parkes LM. Alzheimer's disease pathology is associated with earlier alterations to blood brain barrier water permeability compared with healthy ageing in TgF344‐AD rats. NMR Biomed. 2021;34(7):e4510. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5. Kim YR, Tejima E, Huang S, Atochin DN, Dai G, Lo EH, Huang PL, Bogdanov A, Rosen BR. In vivo quantification of transvascular water exchange during the acute phase of permanent stroke. Magn Reson Med. 2008;60(4):813‐821. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6. Villringer K, Sanz Cuesta BE, Ostwaldt A‐C, Grittner U, Brunecker P, Khalil AA, Schindler K, Eisenblätter O, Audebert H, Fiebach JB. DCE‐MRI blood–brain barrier assessment in acute ischemic stroke. Neurology. 2017;88(5):433‐440. [DOI] [PubMed] [Google Scholar]
  • 7. Brück W, Bitsch A, Kolenda H, Brück Y, Stiefel M, Lassmann H. Inflammatory central nervous system demyelination: correlation of magnetic resonance imaging findings with lesion pathology. Ann Neurol. 1997;42(5):783‐793. [DOI] [PubMed] [Google Scholar]
  • 8. Vos CMP, Geurts JJG, Montagne L, van Haastert ES, Bö L, van der Valk P, Barkhof F,  de Vries HE . Blood brain barrier alterations in both focal and diffuse abnormalities on postmortem MRI in multiple sclerosis. Neurobiol Dis. 2005;20(3):953‐960. [DOI] [PubMed] [Google Scholar]
  • 9. Farrall AJ, Wardlaw JM. Blood–brain barrier: ageing and microvascular disease—systematic review and meta‐analysis. Neurobiol Aging. 2009;30(3):337‐352. [DOI] [PubMed] [Google Scholar]
  • 10. Montagne A, Barnes SR, Sweeney MD, et al. Blood–brain barrier breakdown in the aging human hippocampus. Neuron. 2015;85(2):296‐302. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11. Ohene Y, Harrison IF, Evans PG, Thomas DL, Lythgoe MF, Wells JA. Increased blood brain barrier permeability to water in the aging brain detected using noninvasive multi‐ TE ASL MRI. Magn Reson Med. 2021;85(1):326‐333. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12. Manning C, Stringer M, Dickie B, et al. Sources of systematic error in DCE‐MRI estimation of low‐level blood–brain barrier leakage. Magn Reson Med. 2021;86(4):1888‐1903. [DOI] [PubMed] [Google Scholar]
  • 13. Dickie BR, Parker GJM, Parkes LM. Measuring water exchange across the blood–brain barrier using MRI. Prog Nucl Magn Reson Spectrosc. 2020;116:19‐39. [DOI] [PubMed] [Google Scholar]
  • 14. Rooney WD, Li X, Sammi MK, Bourdette DN, Neuwelt EA, Springer CS. Mapping human brain capillary water lifetime: high‐resolution metabolic neuroimaging. NMR Biomed. 2015;28(6):607‐623. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15. Bai R, Li Z, Sun C, Hsu Y, Liang H, Basser P. Feasibility of filter‐exchange imaging (FEXI) in measuring different exchange processes in human brain, 219. NeuroImage; 2020. [DOI] [PubMed] [Google Scholar]
  • 16. Powell E, Ohene Y, Battiston M, Dickie BR, Parkes LM, Parker GJM. Blood–brain barrier water exchange measurements using FEXI: Impact of modeling paradigm and relaxation time effects. Magn Reson Med. 2023;90(1):34‐50. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17. Ohene Y, Harris WJ, Powell E, et al. Filter exchange imaging with crusher gradient modelling detects increased blood–brain barrier water permeability in response to mild lung infection. Fluids Barriers CNS. 2023;20(1):25. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18. Silva AC, Williams DS, Koretsky AP. Evidence for the exchange of arterial spin‐labeled water with tissue water in rat brain from diffusion‐sensitized measurements of perfusion. Magn Reson Med. 1997;38(2):232‐237. [DOI] [PubMed] [Google Scholar]
  • 19. Wengler K, Bangiyev L, Canli T, Duong TQ, Schweitzer ME, He X. 3D MRI of whole‐brain water permeability with intrinsic diffusivity encoding of arterial labeled spin (IDEALS). NeuroImage. 2019;189:401‐414. [DOI] [PubMed] [Google Scholar]
  • 20. Shao X, Ma SJ, Casey M, D'Orazio L, Ringman JM, Wang DJJ. Mapping water exchange across the blood brain barrier using 3D diffusion‐prepared arterial spin labeled perfusion MRI. Magn Reson Med. 2019;81(5):3065‐3079. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21. Silva AC, Zhang W, Williams DS, Koretsky AP. Estimation of water extraction fractions in rat brain using magnetic resonance measurement of perfusion with arterial spin labeling. Magn Reson Med. 1997;37(1):58‐68. [DOI] [PubMed] [Google Scholar]
  • 22. Gregori J, Schuff N, Kern R, Günther M. T2‐based arterial spin labeling measurements of blood to tissue water transfer in human brain. J Magn Reson. 2013;37(2):332‐342. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23. Wells JA, Siow B, Lythgoe MF, Thomas DL. Measuring biexponential transverse relaxation of the ASL signal at 9.4 T to estimate arterial oxygen saturation and the time of exchange of labeled blood water into cortical brain tissue. J Cereb Blood Flow Metab. 2013;33(2):215‐224. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24. Ohene Y, Harrison IF, Nahavandi P, et al. Non‐invasive MRI of brain clearance pathways using multiple echo time arterial spin labelling: an aquaporin‐4 study. NeuroImage. 2019;188(November 2018):515‐523. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25. Schidlowski M, Boland M, Rüber T, Stöcker T. Blood–brain barrier permeability measurement by bi‐exponentially modeling whole‐brain arterial spin labeling data with multiple T2‐weightings. NMR Biomed. 2020;33(10):e4374. [DOI] [PubMed] [Google Scholar]
  • 26. Lin Z, Li Y, Su P, et al. Non‐contrast MR imaging of blood–brain barrier permeability to water. Magn Reson Med. 2018;80(4):1507‐1520. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27. Lin Z, Jiang D, Liu D, et al. Noncontrast assessment of blood brain barrier permeability to water: shorter acquisition, test retest reproducibility, and comparison with contrast‐based method. Magn Reson Med. 2021;86(1):143‐156. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28. Schwarzbauer C, Morrissey SP, Deichmann R, Hillenbrand C, Syha J, Adolf H, Nöth U, Haase A. Quantitative magnetic resonance imaging of capillary water permeability and regional blood volume with an intravascular MR contrast agent. Magn Reson Med. 1997;37(5):769‐777. [DOI] [PubMed] [Google Scholar]
  • 29. Beaumont H, Pearson A, Van Osch MJ, Parkes LM. In: Proceedings of the 24th Annual Meeting of ISMRM, Singapore.
  • 30. Powell E, Dickie B, Ohene Y, Parker GJM, Parkes LM. Blood–brain barrier water exchange estimation using optimised contrast‐enhanced ASL. In: Proceedings of the 29th Annual Meeting of ISMRM, virtual; 2021.
  • 31. Parkes LM, Tofts PS. Improved accuracy of human cerebral blood perfusion measurements using arterial spin labeling: accounting for capillary water permeability. Magn Reson Med. 2002;48(1):27‐41. [DOI] [PubMed] [Google Scholar]
  • 32. Carr JP, Buckley DL, Tessier J, Parker GJM. What levels of precision are achievable for quantification of perfusion and capillary permeability surface area product using ASL?. Magn Reson Med. 2007;58(2):281‐289. [DOI] [PubMed] [Google Scholar]
  • 33. Alsop DC, Detre JA, Golay X, et al. Recommended implementation of arterial spin‐labeled perfusion MRI for clinical applications: a consensus of the ISMRM Perfusion Study Group and the European Consortium for ASL in Dementia. Magn Reson Med. 2015;73(1):102‐116. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34. Ethofer T, Mader I, Seeger U, Helms G, Erb M, Grodd W, Ludolph A, Klose U. Comparison of longitudinal metabolite relaxation times in different regions of the human brain at 1.5 and 3 Tesla. Magn Reson Med. 2003;50(6):1296‐1301. [DOI] [PubMed] [Google Scholar]
  • 35. Wright PJ, Mougin OE, Totman JJ, et al. Water proton T1 measurements in brain tissue at 7, 3, and 1.5 T using IR‐EPI, IR‐TSE, and MPRAGE: results and optimization. Magn Reson Mater Phys Biol Med. 2008;21(1/2):121‐130. [DOI] [PubMed] [Google Scholar]
  • 36. Woods JG, Chappell MA, Okell TW. A general framework for optimizing arterial spin labeling MRI experiments. Magn Reson Med. 2019;81(4):2474‐2488. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37. Al‐Bachari S, Naish JH, Parker GJM, Emsley HCA, Parkes LM. Blood–brain barrier leakage is increased in Parkinson's disease. Front Physiol. 2020;11:593026. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38. Shen Y, Goerner FL, Snyder C, Morelli JN, Hao D, Hu D, Li X, Runge VM. T1 relaxivities of gadolinium‐based magnetic resonance. Invest Radiol. 2015;50(5):330‐338. [DOI] [PubMed] [Google Scholar]
  • 39. Parker GJM, Roberts C, Macdonald A, et al. Experimentally‐derived functional form for a population‐averaged high‐temporal‐resolution arterial input function for dynamic contrast‐enhanced MRI. Magn Reson Med. 2006;56(5):993‐1000. [DOI] [PubMed] [Google Scholar]
  • 40. Ashburner J, Friston KJ. Unified segmentation. NeuroImage. 2005;26(3):839‐851. [DOI] [PubMed] [Google Scholar]
  • 41. Tzourio‐Mazoyer N, Landeau B, Papathanassiou D, Crivello F, Etard O, Delcroix N, Mazoyer B, Joliot M. Automated anatomical labeling of activations in SPM using a macroscopic anatomical parcellation of the MNI MRI single‐subject brain. NeuroImage. 2002;15(1):273‐289. [DOI] [PubMed] [Google Scholar]
  • 42. Dickie BR, Banerji A, Kershaw LE, McPartlin A, Choudhury A, West CM, Rose CJ. Improved accuracy and precision of tracer kinetic parameters by joint fitting to variable flip angle and dynamic contrast enhanced MRI data. Magn Reson Med. 2016;76(4):1270‐1281. [DOI] [PubMed] [Google Scholar]
  • 43. Rorden C, Brett M. Stereotaxic display of brain lesions. Behav Neurol. 2000;12(4):191‐200. [DOI] [PubMed] [Google Scholar]
  • 44. Xu G, Rowley HA, Wu G, Alsop DC, Shankaranarayanan A, Dowling M, Christian BT, Oakes TR, Johnson SC. Reliability and precision of pseudo‐continuous arterial spin labeling perfusion MRI on 3.0 T and comparison with 15O‐water PET in elderly subjects at risk for Alzheimer's disease. NMR Biomed. 2010;23(3):286‐293. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 45. Liu AA, Voss HU, Dyke JP, Heier LA, Schiff ND. Arterial spin labeling and altered cerebral blood flow patterns in the minimally conscious state. Neurology. 2011;77(16):1518‐1523. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46. Parkes LM, Rashid W, Chard DT, Tofts PS. Normal cerebral perfusion measurements using arterial spin labeling: reproducibility, stability, and age and gender effects. Magn Reson Med. 2004;51(4):736‐743. [DOI] [PubMed] [Google Scholar]
  • 47. Liu Y, Zhu X, Feinberg D, Guenther M, Gregori J, Weiner MW, Schuff N. Arterial spin labeling MRI study of age and gender effects on brain perfusion hemodynamics. Magn Reson Med. 2012;68(3):912‐922. [DOI] [PubMed] [Google Scholar]
  • 48. Juttukonda MR, Li B, Almaktoum R, Stephens KA, Yochim KM, Yacoub E, Buckner RL, Salat DH. Characterizing cerebral hemodynamics across the adult lifespan with arterial spin labeling MRI data from the Human Connectome Project—Aging. NeuroImage. 2021;230:117807. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 49. Lin Z, Lance E, McIntyre T, et al. Imaging blood brain barrier permeability through MRI in pediatric sickle cell disease: a feasibility study. J Magn Reson Imaging. 2022;55(5):1551‐1558. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 50. Silvennoinen MJ, Kettunen MI, Kauppinen RA. Effects of hematocrit and oxygen saturation level on blood spin–lattice relaxation. Magn Reson Med. 2003;49(3):568‐571. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

nbm5009‐sup‐0001‐Supporting Information.pdf

Data Availability Statement

The data that support the findings of this study are available on request from the corresponding author. The data are not publicly available due to privacy or ethical restrictions.