Skip to main content
European Heart Journal. Case Reports logoLink to European Heart Journal. Case Reports
. 2024 Mar 7;8(3):ytae098. doi: 10.1093/ehjcr/ytae098

Primary percutaneous intervention in an unusual vessel using an unusual technique: a case report

Mohit D Gupta 1,, Ankur Gautam 2, Girish MP 3, Ankit Bansal 4, Vishal Batra 5,2
Editors: Krishnaraj Rathod, Michelle Feijen, Mariame Chakir, Ugur Canpolat, Pok-Tin Tang
PMCID: PMC10919390  PMID: 38454961

Abstract

Background

Primary percutaneous intervention (PPCI) of the saphenous vein graft (SVG) is associated with a high risk of distal embolization and no reflow, since SVG lesions are often very friable and have a large thrombotic burden. We report a case of successful PPCI of the SVG using guide catheter thrombectomy with novel double wire technique.

Case summary

A 60-year-old male with a past history of coronary artery bypass grafting presented with acute thrombotic occlusion of the SVG to the obtuse marginal graft. Despite appropriate pharmacotherapy (GPIIb/IIIa inhibitors) and thrombosuction, there was a large residual thrombus burden with poor distal flow. In the present case, we decided to perform guide catheter thrombosuction. An exchange length floppy 0.014' wire was passed alongside the pre-existing wire and the 6 Fr JR guide catheter was exchanged for a less traumatic 5 Fr JR guide catheter over the exchange wire. The first wire was kept distally in the vessel along the guiding catheter to maintain the access to the graft vessel. The 5 Fr JR guide catheter was slowly advanced over the wire to the distal portion of the graft, keeping the other wire in the distal portion of the graft to maintain access. A large amount of thrombus was aspirated and the patient improved dramatically.

Discussion

This double wire technique is an effortless and novel way to maintain access to the distal vasculature of the occluded artery, while the guide can be safely intubated deep into the coronary artery that helps in removing a very large amount of thrombus because of their larger internal lumen.

Keywords: Saphenous vein graft, Primary percutaneous coronary intervention, Thrombosuction, Guide thrombectomy, Case report


Learning points.

  • Primary percutaneous intervention of the saphenous vein graft (SVG) disease is a major challenge since patients with SVG diseases often have a high-risk profile and SVG lesions often are friable with a large thrombus burden as well.

  • Guide catheter thrombosuction can be used as a bailout modality in situations where pharmacological therapy and thrombosuction catheter fail to restore the flow.

  • A simple double wire in situ technique ensures prompt and true access to the lumen of the coronary artery even if dissection occurs or the distal vessel collapses.

Introduction

Percutaneous coronary intervention (PCI) of the saphenous vein graft (SVG) is challenging and associated with poor outcomes.1 Saphenous vein graft lesions are frequently complex and have a large amount of friable thrombus. These often lead to extensive dissection, severe distal embolization resulting in no reflow or slow flow, and consequently adverse outcomes.2 We report a case of successful primary PCI in the SVG performed using guide catheter thrombosuction with double wire technique.

Summary figure

graphic file with name ytae098il2.jpg

Case presentation

A 60-year-old diabetic, hypertensive, and non-smoker male presented to our emergency at odd hours with 3 h chest pain. He had a history of coronary artery bypass grafting 10 years ago, with left internal mammary artery graft (LIMA) to the left anterior descending artery (LAD) and SVGs to an obtuse marginal (OM), to the right posterior descending artery (RPDA), and to the ramus intermedius (RI) artery. On presentation, his blood pressure was 132/84 mmHg with a pulse rate of 120 b.p.m., respiratory rate of 20 breaths/min, and random blood sugar of 172 mg/dL. The general physical and cardiovascular examinations did not reveal any specific findings. His electrocardiogram showed ST segment elevation in leads I, aVL, V5, and V6 indicative of lateral wall myocardial infarction (MI) (Figure 1). Bedside echocardiography showed new regional wall motion abnormalities (RWMA) in the posterolateral wall with left ventricular ejection fraction (LVEF) of 50%. His previous echocardiography report showed normal LVEF without any RWMA. The patient received loading dose of 325 mg of aspirin and 180 mg of ticagrelor. He was immediately transferred to the cardiac catheterization laboratory for coronary angiography (CAG).

Figure 1.

Figure 1

Electrocardiogram at the time of presentation.

Coronary angiography revealed severe disease in native coronary arteries with occluded LAD and RCA and diffusely diseased OM and RI. Angiography of graft vessels showed patent LIMA to LAD, SVG to RI, and SVG to RPDA and acute thrombotic occlusion of the SVG to the OM graft (Figure 2A) (see supplementary material online, Video S1). In view of ongoing chest pain and haemodynamic instability (blood pressure of 90/64 mmHg), we decided to perform primary PCI of the SVG to the OM.

Figure 2.

Figure 2

(A) Angiogram revealed complete thrombotic occlusion of the saphenous vein graft to an obtuse marginal. (B) Thrombosuction using thrombus aspiration catheter (arrow). (C) Angiogram showed larger thrombus burden (arrow) despite using thrombus aspiration catheter.

The SVG graft was engaged with 6 Fr Judkins right (JR) guiding catheter (Medtronic, Minneapolis, USA). The lesion was crossed with a hydrophilic 0.014' guidewire (HI-TORQUE WHISPER ES Guide Wire™ Abbott Vascular, IL, USA). Abciximab was administered 0.25 mg/kg IV bolus followed by infusion of 0.125 mcg/kg/min. In view of the large thrombus burden, thrombosuction was carried out with a thrombus aspiration catheter (Export Advance™ Medtronic, Minneapolis, USA) (Figure 2B) (see supplementary material online, Video S2). Despite pharmacologic and mechanical tools, there was a large residual thrombus burden in the vessel with poor distal flow (Figure 2C) (see supplementary material online, Video S3). Due to the deteriorating condition of the patient and unavailability of any other modality, we decided to perform guide catheter thrombosuction. One exchange length floppy tip wire 0.014' (Boston Scientific, Inc, Maple Grove, Minnesota) was passed alongside the pre-existing WHISPER wire, and the 6 Fr JR guiding catheter was changed to a less traumatic 5 Fr JR guiding catheter over the exchange length floppy wire (Figure 3A and B). Anticipating the possibility of dissection and difficult rewiring of the vessel, following guide thrombectomy, the WHISPER wire was kept distally in the vessel along the guiding catheter to maintain the access to the graft vessel.

Figure 3.

Figure 3

Safe removal of the 6 Fr JR guide catheter with exchange for a 5 Fr JR guide catheter while maintaining a wire in the distal segment of the saphenous vein graft (SVG) along the guide catheter. (A) The 6 Fr JR guide catheter (arrow) was removed. (B) A 5 Fr JR guide (arrow) was advanced over the exchange length floppy wire. (C) The guide catheter (arrow) thrombosuction into the SVG. (D) A large amount of thrombus material following flushing the catheter.

The 5 Fr JR guiding catheter was slowly advanced over the wire to the distal of the graft, and the floppy wire was removed (Figure 3C) (see supplementary material online, Video S4). The hub of the guide catheter was disconnected from the Y-connector and a 20 mL Luer-Lok syringe (Becton Dickinson) was attached. Maintaining a constant and moderate negative suction, the guide catheter was slowly withdrawn from the artery and out of the femoral sheath. A large amount of thrombus was detected following flushing of the catheter (Figure 3D). While all this was done, the WHISPER wire was in the graft to ensure access to the distal graft vessel. There was dramatic improvement in clinical condition of the patient with stabilization of haemodynamic status. The 6 Fr JR guide was then advanced over the WHISPER wire and the vessel was engaged (Figure 4A). Subsequent angiogram revealed marked improvement in TIMI flow with very small residual thrombus (Figure 4B) (see supplementary material online, Video S5). The culprit lesion at the proximal SVG graft had significant stenosis. The lesion was stented with a sirolimus-eluting stent Ultimaster (Terumo, Tokyo, Japan) 3.0 × 38 mm at 9 atm (Figure 4C). The final angiogram showed TIMI 3 flow in the vessel (Figure 4D) (see supplementary material online, Video S6). The course of hospital stay was uneventful. The patient was discharged on Day 4 with aspirin 75 mg once daily and ticagrelor 90 mg twice daily as dual antiplatelet therapy, atorvastatin 40 mg once daily, and telmisartan 40 mg once daily along with oral hypoglycaemic agents.

Figure 4.

Figure 4

(A) Finally, the 5 Fr guide catheter was removed and exchanged with a 6 Fr JR guide catheter (arrow) over the WHISPER wire which was kept distally in the graft vessel. (B) Angiogram revealed a very small amount of residual thrombus (arrow) following guide catheter thrombosuction. (C) A drug-eluting stent was implanted (arrow) at the proximal SVG lesion. (D) Angiographically success result.

Discussion

The incidence of major adverse cardiac events after primary PCI in SVGs is remarkably higher than other vessels.3 Saphenous vein grafts have a tendency of slow flow because they are large diameter vessels anastomosed to smaller, native coronary arteries. Moreover, SVG lesions are often very friable and have a very thin fibrous cap with a large thrombotic burden.4 These peculiarities might cause distal embolization of athero-thrombotic debris that makes it challenging to achieve a good TIMI flow.5

Primary PCI in such cases is challenging and often associated with an increased risk of intraoperative complications like slow flow, no reflow, and fatal arrhythmias and mortality. Although routine manual thrombosuction has not shown to be beneficial, in a subgroup analysis of cases with high thrombus burden, a bailout treatment strategy of thrombus aspiration showed favourable outcomes.6 We did not use an embolic protection device in the present case. The utility of embolic protection devices during the primary PCI of SVG lesions has failed to show any benefit.7

In the present case, appropriate pharmacotherapy and thrombosuction failed to provide the desired result in a clinically deteriorating patient with occluded SVG with a large thrombus burden. In such a difficult situation, guide catheter thrombosuction was used as a bailout strategy to salvage the patient. Manual thrombus aspiration catheters have smaller internal diameter (ID) of 0.041' and often result in inadequate thrombus removal or clot migration resulting in risk of thromboembolism. Direct thrombus aspiration with guide catheter following deep coronary intubation helps in removing a very large amount of thrombus because of their larger internal lumen (IDs of 6 Fr and 5 Fr catheter are 0.071' and 0.058', respectively) as compared with conventional aspiration catheter.8 However, the guide catheter suction is associated with significant risks. It may cause endothelial damage, coronary artery dissections, and even collapse of the distal vessel.9 We therefore used a simple double wire technique to avoid these complications and achieve successful reperfusion. This double wire technique is an effortless and novel way to maintain access to the distal vasculature of the occluded artery, while the guide can be safely intubated deep into the coronary artery depending upon the thrombus burden.10 Even if the dissection occurs or the distal vessel collapses, the presence of a wire in the vessel will ensure prompt and true access to the lumen of the coronary artery. In the present case, the catheter was aligned almost straight on the graft, so the large thrombus could be extracted without major injury to the vessel wall. The use of a soft-tip guiding catheter and its cautious advancement over the wire prevented any catheter-induced trauma or dissection of the vessel. In addition, maintaining continuous negative suction on the syringe while withdrawing the guiding catheter out of the sheath minimized the risk of systemic embolization. We avoided pre- and post-dilatation and the stent was deployed at nominal pressure.

Conclusion

This case demonstrates the feasibility of using guide catheter thrombus aspiration with a simple double wire in situ to restore circulation in the occluded graft vessel with a large thrombus burden as a bailout measure.

Supplementary Material

ytae098_Supplementary_Data

Contributor Information

Mohit D Gupta, Department of Cardiology, GB Pant Hospital, 1, Jawaharlal Nehru Marg, 64 Khamba, Raj Ghat, New Delhi 110002, India.

Ankur Gautam, Department of Cardiology, GB Pant Hospital, 1, Jawaharlal Nehru Marg, 64 Khamba, Raj Ghat, New Delhi 110002, India.

Girish MP, Department of Cardiology, GB Pant Hospital, 1, Jawaharlal Nehru Marg, 64 Khamba, Raj Ghat, New Delhi 110002, India.

Ankit Bansal, Department of Cardiology, GB Pant Hospital, 1, Jawaharlal Nehru Marg, 64 Khamba, Raj Ghat, New Delhi 110002, India.

Vishal Batra, Department of Cardiology, GB Pant Hospital, 1, Jawaharlal Nehru Marg, 64 Khamba, Raj Ghat, New Delhi 110002, India.

Lead author biography

Inline graphicDr Mohit D. Gupta, MD, DM, FRCP (Edin), FACC, FSCAI, FESC, FCSI, FAPI, is a professor of cardiology in Govind Ballabh Pant Institute of Postgraduate Medical Education and Research, New Delhi, 110002. He is the principle investigator of the NORIN STEMI registry. He is the Executive Editor of the Indian Heart Journal.

Supplementary material

Supplementary material is available at European Heart Journal – Case Reports online.

Consent: Written informed consent was obtained from the patient.

Funding: None declared.

Data availability

The data underlying this article are available in the article and its online supplementary material.

References

  • 1. Brodie  BR, VerSteeg  DS, Brodie  MM, Hansen  C, Richter  SJ, Stuckey  TD, et al.  Poor long-term patient and graft survival after primary percutaneous coronary intervention for acute myocardial infarction due to saphenous vein graft occlusion. Catheter Cardiovasc Interv  2005;65:504–509. [DOI] [PubMed] [Google Scholar]
  • 2. Cook  J, Uretsky  BF, Sachdeva  R. Intervention in the occluded vein graft: with high risk can come great reward: review of techniques with case examples. J Invasive Cardiol  2012;24:612–617. [PubMed] [Google Scholar]
  • 3. Redfors  B, Généreux  P, Witzenbichler  B, McAndrew  T, Diamond  J, Huang  X, et al.  Percutaneous coronary intervention of saphenous vein graft. Circ Cardiovasc Interv  2017;10:e004953. [DOI] [PubMed] [Google Scholar]
  • 4. de Winter  RW, Walsh  SJ, Hanratty  CG, Spratt  JC, Sprengers  RW, Twisk  JWR, et al.  Percutaneous coronary intervention of native coronary artery versus saphenous vein graft in patients with prior coronary artery bypass graft surgery: rationale and design of the multicenter, randomized PROCTOR trial. Am Heart J  2023;257:20–29. [DOI] [PubMed] [Google Scholar]
  • 5. Xenogiannis  I, Zenati  M, Bhatt  DL, Rao  SV, Rodés-Cabau  J, Goldman  S, et al.  Saphenous vein graft failure: from pathophysiology to prevention and treatment strategies. Circulation  2021;144:728–745. [DOI] [PubMed] [Google Scholar]
  • 6. Jolly  SS, Cairns  JA, Yusuf  S, Meeks  B, Pogue  J, Rokoss  MJ, et al.  Randomized trial of primary PCI with or without routine manual thrombectomy. N Engl J Med  2015;372:1389–1398. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7. Alak  A, Jolly  SS. The role of manual aspiration thrombectomy in patients undergoing primary percutaneous coronary intervention for STEMI. Curr Cardiol Rep  2016;18:30. [DOI] [PubMed] [Google Scholar]
  • 8. Shimada  Y, Kino  N, Fukumoto  H. Direct aspiration of large thrombi in acute myocardial infarction using a standard 6 Fr guide catheter via the transradial approach. J Invasive Cardiol  2012;24:E283–E288. [PubMed] [Google Scholar]
  • 9. Ben-Dor  I, Pichard  AD, Waksman  R. Combined mechanical and pharmacological approach to a thrombus-containing lesion. Catheter Cardiovasc Interv  2010;75:972–976. [DOI] [PubMed] [Google Scholar]
  • 10. Girish  MP, Gupta  MD, Tyagi  S. Guide catheter suction with novel double wire technique for successful management of large thrombus in occluded right coronary artery. J Invasive Cardiol  2012;24:141–143. [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

ytae098_Supplementary_Data

Data Availability Statement

The data underlying this article are available in the article and its online supplementary material.


Articles from European Heart Journal: Case Reports are provided here courtesy of Oxford University Press

RESOURCES