Summary
We present our continuous efforts from a modeling and numerical viewpoint to develop a powerful and flexible mathematical and computational framework called Ocular Mathematical Virtual Simulator (OMVS). The OMVS aims to solve problems arising in biomechanics and hemodynamics within the human eye. We discuss our contribution towards improving the reliability and reproducibility of computational studies by performing a thorough validation of the numerical predictions against experimental data. The OMVS proved capable of simulating complex multiphysics and multiscale scenarios motivated by the study of glaucoma. Furthermore, its modular design allows the continuous integration of new models and methods as the research moves forward, and supports the utilization of the OMVS as a promising non-invasive clinical investigation tool for personalized research in ophthalmology.
Keywords: mathematical and computational ophthalmology, multiphysics and multiscale modeling, Hybridizable Discontinuous Galerkin method, validation, ocular hemodynamics and biomechanics
Graphical Abstract

In our research, we introduce the Ocular Mathematical Virtual Simulator (OMVS), a robust computational framework for multiscale and multiphysics modelling of biomechanics and hemodynamics in the human eye. Rigorously validated against experimental data, the OMVS excels in simulating diverse glaucoma-related scenarios. Its modular design ensures adaptability, enabling the continuous integration of new models. With potential as a promising non-invasive clinical tool, the OMVS supports personalised ophthalmology research.
1 |. INTRODUCTION
The interest in patient-specific mathematical models applied to biomedical problems has greatly increased in the last years. To provide meaningful and complementary insights to traditional research, these models should build upon clinical measures inputs combined with physiological knowledge. In order to fully exploit their quantitative predictive capabilities, a complete pipeline should next be developed and should incorporate: data integration, model derivation, numerical solving, validation and uncertainty quantification. Significant research progress was accomplished towards these challenging goals in specific biomedical applications, e.g. cardiovascular simulations1,2 or cerebral hemodynamics3,4, which are now quite mature and well-established research fields. Moreover, efficient computational frameworks5,6 oriented towards medical applications successfully tackled such complex multiphysics and multiscale problems and provided useful insights to interesting clinical questions.
In the field of ophthalmology, a similar paradigm is needed: the availability of rich, heterogeneous data published in the literature, possibly making contradictory statements and the lack of understanding of the underlying mechanisms of several ocular diseases, calls for innovative approaches to help diagnosis and monitoring of these clinical conditions. For a recent review of the state-of-the-art and the open questions, see for instance7,8 and the references therein. However, computational and mathematical ophthalmology is still an emergent field and to the best of our knowledge, only few studies focused on this particular topic, as reviewed for example in9,10 or, in the context of uncertainty quantification, in11,12.
The present work aims to contribute to this growing area of research by proposing a novel modeling and simulation environment, called the Ocular Mathematical Virtual Simulator (OMVS). From a clinical viewpoint, the focus of the present work is on glaucoma. The reasons are manifold: it is a leading cause of irreversible blindness worldwide, its prevalence increases with age, it poses a significant public health burden, it currently lacks a cure, existing treatments focus on managing the condition and slowing its progression. Our collaborative research with the specialist center at the Icahn School of Medicine, Mount Sinai (NY) provides a unique opportunity to develop a multidisciplinary approach to tackle these issues. Specifically, the OMVS has the purpose to provide a window on both ocular biomechanics and hemodynamics from a macroscale viewpoint. Moreover, this innovative framework means to account for the complexity stemming from the availability of data and their heterogeneity due different measurement techniques13,14. The multiscale and multiphysics characteristics dictated by data acquisition and the application itself have been considered from the beginning in the design and accounted thanks to a modular structure. On one hand, the combined effects of ocular blood flow and different ocular tissues are described by a coupled hemodynamics and biomechanics model. On the other hand, the multiscale aspect, essential to properly account for systemic effects of blood circulation coupled with local effects on tissues of interest, is represented by a coupled partial and ordinary differential equations for fluid flow. More details about these multiphysics and multiscale features and the associated developments are provided in Sec. 2, while Sec. 4 discusses information about geometrical and functional parameters utilized as OMVS input data.
The next challenge within the OMVS development is to have a robust and efficient numerical strategy able to preserve the physical properties at the discrete level. To address this ambitious goal, suitable innovative methods are adopted: a Hybridazable Discontinuous Galerkin (HDG) method with an original integral boundary condition15 detailed in Sec. 3.2 and a novel effective multiscale coupling solving method described in Sec. 3.1.
A preliminary version of the OMVS has been presented in16 and subsequently used in17 to target specific clinical applications related to glaucoma. A detailed uncertainty quantification and global sensitivity analysis study was conducted for a reduced version of the OMVS framework in18. However, until now, the full OMVS framework and the specific question of its validation have not been tackled directly yet. We therefore describe in Sec. 5 the results of a thorough validation analysis. Finally, a comprehensive scheme of the different connections between data and models within the OMVS framework can be found in Fig. 1, illustrating our paradigm and validation strategy.
FIGURE 1.

General design and strategy of the Ocular Mathematical Virtual Simulator (OMVS) framework.
2 |. HEMODYNAMICS AND BIOMECHANICS IN THE HUMAN EYE: A MULTISCALE MODEL
The OMVS framework is based on a multiscale mathematical description of blood circulation (or hemodynamics) and tissue deformation (or biomechanics) in various parts of the eye. Specifically, the anatomical regions considered in this work are sclera, cornea, lamina cribrosa, retina and choroid, see Fig. 2. The multiscale approach is adopted to couple models of different complexity for the hemodynamic and/or biomechanic behaviors in different anatomical regions depending on their relevance for the study at hand, as detailed below.
FIGURE 2.

Anatomy of the eye. Image created with BioRender19.
The current development of the OMVS is motivated by the study of glaucoma, for which the lamina cribrosa is considered to be a site of particular interest due to its crucial role in the balance of pressures between the eye and the brain20. However, direct measurements within this tissue are difficult or even impossible to obtain in clinical practice, thus alternative approaches are investigated.
The modeling of the lamina cribrosa is not a novelty in the scientific panorama, indeed this tissue has raised a lot of interest from a biomechanical viewpoint21,22,23,24,25,26. On the other hand, few studies have been completed on the hemodynamics of the lamina27. For this reason, the lamina cribrosa is modeled here as a three-dimensional (3D) poroelastic medium, with the goal of capturing the interaction between the blood flow through the tissue and the deformation of the tissue itself (see Section 2.2). However, blood flow and tissue deformation occurring within the lamina are also influenced by non-local factors, such as systemic blood pressure, that need to be taken into account in order to obtain physiologically-reasonable solutions (see Section 2.1).
Tissue deformations in the lamina cribrosa are mainly due to the load induced by intraocular pressure (IOP) and cerebrospinal fluid pressure (CSFp) acting on its inner and outer surfaces, respectively. However, these surfaces also experience a transversal tension due to the overall IOP-related inflation of the eye ball. This transversal tension can be incorporated in the model in several ways: either as given boundary conditions similarly to the approach proposed in28, or as interface conditions between the lamina cribrosa and the sclera. In the present work, we employ the latter strategy, which requires the lamina cribrosa to be coupled with models for other ocular tissues via interface conditions expressing the continuity of displacements and stresses (see Section 2.4). The other ocular tissues we account for in the present contribution are sclera, cornea, retinal nerve fiber layer and choroid, described as elastic media (see Section 2.3) This approach has the advantage of providing a global description of the biomechanics of main tissues composing the eye ball.
The blood supply to the lamina cribrosa is provided by the posterior ciliary arteries, which branch out from the ophthalmic artery before the central retina artery (CRA), whereas the blood drainage occurs via the central retinal vein (CRV), which also drains the retina (see Fig. 3). Thus, the hemodynamic conditions within the lamina cribrosa are inherently coupled with the hemodynamics in the central retinal vessels and in the retinal vasculature. To capture this interaction, the circulation in the CRA, CRV and retina are modeled via a zero-dimensional (0D) model based on a nonlinear system of ordinary differential equations (ODEs) describing blood flow as the analogous of an electric current flowing through an electric circuit (see Section 2.1). Next, we employ a multiscale connection between the 0D network and the 3D description of the hemodynamics in the lamina cribrosa. In particular, the idea is to have a first approximation of the contribution of the lamina cribrosa perfusion incorporated in the retinal vasculature via the 0D model described in Section 2.1. Then a more detailed 3D lamina cribrosa representation is introduced by means of the coupling between the hemodynamics and the biomechanics via the poroelastic model presented in Section 2.2. A suitable exchange of information between the 0D model for the circulation in CRA/CRV/retina and the 3D poroelastic medium for the circulation in the lamina cribrosa must be prescribed in order to ensure the continuity of mass and pressure (see Section 2.4). Finally, the description of the geometry, computational mesh, and parameter values utilized in the models is postponed to Section 4.
FIGURE 3.

Scheme of the blood supply and drainage for the lamina cribrosa and retina employed in our model.
2.1 |. A 0D network model for the circulation in the retina and the central retinal vessels
A nonlinear system of ODEs is utilized as a simplified representation of the blood circulation in the retina, CRA and CRV. The blood circulation is modelled via a lumped-parameter model, which exploits the electric analogy to fluid flow29 Chapter 15. Within this analogy, the flow of a fluid through a hydraulic network corresponds to the flow of an electric current through an electric circuit. Thus, volume, flow rate, fluid velocity, pressure correspond to electric charge, current, current density, potential, respectively.
The ODEs model illustrated in Fig. 4 stems from the circuit described and validated in30 and31. The vasculature is divided into six main compartments: lamina cribrosa , CRA , arterioles , capillaries , venules , and CRV . Each compartment includes resistances and capacitances . The intraocular segments are exposed to the IOP and the retrobulbar segments are exposed to the pressure within the optic nerve tissue, also referred to as retrolaminar tissue pressure (RLTp). IOP is mainly due to the pressure of aqueous humor in the anterior chamber, whereas RLTp is mainly due to the pressure of the cerebrospinal fluid in the subarachnoid space32. The lamina cribrosa compartment, with inner pressure , corresponds to a 0D simplified description of the hemodynamics in this tissue.
FIGURE 4.

Circuit representing the circulation in the lamina cribrosa, the retina and the central retinal vessels.
In the original circuit the external pressure on the resistances and is the effective stress exerted by the lamina on these vessels, which has been computed via the simplified FSI (fluid-structure interaction) model studied in33 on the CRA/CRV interaction with the lamina cribrosa. In the present lumped-parameter model (Fig. 4), this contribution has been simplified and the external pressure felt by the CRA/CRV is only due to the IOP in the intraocular and translaminar segments, and to the RLTp in the retrobulbar segments.
Similarly to the work presented in34,29,31, we employ the following modeling choices for the nonlinear resistors in the circuit:
| (1) |
| (2) |
where is the length of the vessel, is the average pressure inside the vessel, is the external pressure to the vessel, and and are univocally characterizing the nonlinear resistive behaviour.
Eq. (1) assumes that the cross-section remains circular in presence of external pressures; this situation applies to . Eq. (2) models a Starling resistor behaviour, which is based on experiments suggested by35,36. In particular, this formula expresses the fact that, in case of compressible tubes, the circular cross-section is preserved for dilation, whereas when the transmural pressure becomes negative the cross-section shape reflects the physiological high collapsibility of the venous segments. follow this equation.
2.2 |. A 3D poroelastic model for the lamina cribrosa
In this section we introduce the 3D model for the lamina cribrosa. We describe it as a poroelastic medium, where hemodynamics and biomechanics are combined with the goal of studying their interactions, as they are essential for the physiological functions of this tissue. To this end, let us consider the poroelastic system introduced by Biot37 and subsequently studied by38,39,40,41:
| (3a) |
| (3b) |
where is the computational domain, is the solid displacement, is the stress tensor of the mixture, also known as total stress, is the volumetric force term, is the fluid pressure, is the Biot coefficient, is the discharge velocity, is the volumetric fluid source term, and is the fluid content. The constitutive laws for , and are:
| (4a) |
| (4b) |
| (4c) |
| (4d) |
where is the Biot modulus, and are the Lamé parameters of the elastic matrix, and is the permeability tensor. In the context of this study, Eq. (3a) and Eq. (3b) represent the lamina biomechanics and hemodynamics, respectively. Guided by the particular application at hand, we make the following assumptions and considerations:
The volumetric source term in Eq. (3b) is assumed to be zero, i.e. . This implies that stresses and strains inside the lamina are merely due to its boundary conditions, i.e. IOP and CSFp, and interface conditions, i.e. coupling with other ocular tissues (see Sec. 2.4).
The volumetric source term in Eq. (3a) is assumed to be zero, i.e. . This assumption implies that blood circulating in the lamina is solely provided by a multiscale effective connection between the lamina and the posterior ciliary arteries on the arterial side, and between the lamina and the CRV on the venous side (see Sec. 2.4).
Changes in fluid content are assumed to be mostly due to changes in pressure, so that the term can be neglected in Eq. 4a).
Thus, we obtain the following simplified system of PDEs:
| (5a) |
| (5b) |
Referring to the same constitutive laws described in (4), system (5a) and (5b) is accompanied by appropriate boundary (BCs) and initial conditions (ICs), which are discussed in Sec. 2.4.
Remark 1. The well posedness of the poroelastic system (3) is proved in42,43.
Remark 2. In the context of lamina cribrosa modeling, various extensions of the Biot system have been considered, such as the use of a nonlinear model to describe its biomechanics44 and the use of a poroviscoelastic model to characterize the interaction between the blood flow and the elastic tissue within the optic nerve head45,43,46. In this work, we opted to consider the simplified system (5) since the focus of our study is the coupling between the lamina biomechanics and hemodynamics and the circulation upstream and downstream of the lamina (Sec. 2.1). Thus, the simplified system (5) should be seen as a first step to create the “big picture” of an ocular system in which each mathematical component could be replaced with more sophisticated models adapted as the research evolves.
To simplify the presentation, we detail hereafter the hemodynamics and the biomechanics of the model proposed in Eqs. (5) separately as sketched in Fig. 5.
FIGURE 5.

Poroelastic model framework for the lamina cribrosa.
Hemodynamics of the lamina cribrosa
We consider here just the contribution of Eq. (5b) and its mixed formulation: find such that
| (6) |
endowed with appropriate initial conditions, where corresponds to the lamina cribrosa domain. The choice of the boundary conditions for the fluid flow through the lamina is of particular importance, given that blood enters the lamina from the branches of the posterior ciliary arteries located at its outer boundary and it is drained by the central retinal vein running through the lamina transversally in its course from the retina to the cavernous sinus. These concepts are schematized in Fig. 6a. We adopt the isotropic hypothesis (Fig. 6b) for the permeability tensor which accounts for capillaries within the tissue of the lamina. Thus, we assume that with a given permeability . This approximation hypothesis has been also supported by experimental studies47.
FIGURE 6.

Hemodynamic model framework for the lamina cribrosa.
Biomechanics of the lamina cribrosa
For what concerns the biomechanics, we consider the contribution of Eq. (5a) and its mixed formulation: find such that
| (7) |
together with appropriate initial conditions. Specifically, in the biomechanics part, we consider the contribution of the extracellular matrix, the collagen beams and nerve bundles as described in Fig. 6b, but we neglect the biomechanical behaviour of the blood vessels.
2.3 |. A 3D biomechanical model for the sclera, choroid, retina and cornea
In this section we discuss the model that represents the biomechanics within the sclera (Fig. 7a), choroid (Fig. 7b), retina (Fig. 7c) and cornea (Fig. 7d). In this case we adopt a mixed formulation of the classic linear elastic problem: find defined on with such that
| (8) |
endowed with appropriate initial conditions.
FIGURE 7.

Ocular tissue domains introduced in the biomechanical description of the OMVS.
2.4 |. Boundary and interface conditions in the OMVS framework
This section illustrates the boundary conditions that are adopted for the PDE systems and the interface conditions that describe the coupling among all the model blocks within the multiscale system.
Hemodynamics within the lamina cribrosa.
The conditions to be imposed at the surfaces delimiting the lamina cribrosa are depicted in Fig. 8. Specifically, we have:
| (9a) |
| (9b) |
| (9c) |
where is the boundary delimiting the lamina cribrosa and is the outward unit normal vector.
FIGURE 8.

Hemodynamics boundary conditions for the lamina cribrosa in the OMVS.
The notations and refer to the variables obtained from the 0D model (Sec. 2.1). These conditions replicate the physiology of the lamina cribrosa. This tissue is nourished through the lateral boundaries, and finally the blood is gathered by the CRV at the central opening (Fig.6a). Eq. 9a) describes the physiological drainage through the CRV in a simplified manner, via a Dirichlet boundary condition, where the value of is given (see Sec. (4). Eq. (9b) corresponds to the physiological situation where there are no outward fluxes from the top or the bottom surfaces of the lamina. Eqs. (9c) represents the nourishment of the lamina cribrosa. This condition describes the feedback from the ODEs circuit to the hemodynamics part of the poroelastic model. The main advantages are:
this framework provides a zoom in a region of interest for the lamina cribrosa, while accounting for systemic feedback via the 0D circuit;
- the value is constant on thanks to the integral condition we have adopted (Eq. (9c)):
(10) the mixed formulation in Eq. (6) provides the natural spatial multiscale connection between the 3D flux and its 0D representation in the circuit .
Biomechanics of the lamina cribrosa.
The interface and boundary conditions pertaining to the lamina biomechanics are summarized in Fig. 9.
FIGURE 9.

Biomechanical boundary and interface conditions for the lamina cribrosa in the OMVS.
Interface conditions are imposed on the external lateral boundary . Here the lamina connects with the sclera and we require the continuity of displacement and stress as follows:
| (11a) |
| (11b) |
on .
The BCs are depicted in Fig. 9, i.e. we have:
-
on the internal boundary of the lamina
(11c) in this case due to lack of biological information we assumed that all the internal boundaries feel the same pressure (more details on the value of this pressure in Sec. 4) that is compressing (negative sign) ;
-
on the top boundary
(11d) the negative sign is to indicate the fact that IOP is compressing the tissue;
-
on the bottom boundary
(11e) also in this case the negative sign is to indicate the compressing effect of the CSF behind the eye on the tissue.
Biomechanics of sclera, choroid, retina and cornea.
First we list the boundary conditions associated with the description given in system (8) for the biomechanical behaviour of sclera, choroid, retina and cornea, where
(top left panels of Fig. 10 and 11),
(top right panels of Fig. 10 and 11),
(bottom left panels of Fig. 10 and 11), and
(bottom right panels of Fig. 10 and 11).
FIGURE 10.

Boundary condition labels of the OMVS geometry. The original geometry has been clipped along the z-plane in order to view within the eye. For each subfigure, the domain of interest is highlighted in red.
FIGURE 11.

Interface condition labels of the OMVS geometry. The original geometry has been clipped along the z-plane in order to view within the eye. For each subfigure, the domain of interest is highlighted in red.
Thus, we have for the sclera:
on and ;
on and
For the choroid, BCs read:
on ;
on .
For the retina we have:
on
on .
Finally, we impose the following BCs for the cornea:
on ;
on .
Second, we impose the continuity of stresses and displacements on the interfaces between these ocular tissues, namely sclera, choroid, retina and cornea:
on ;
on ;
on ;
on ;
on ;
on .
3 |. NUMERICAL METHODS AND COMPUTATIONAL FRAMEWORK
In this section we present the discretization methods adopted in order to numerically solve the multiscale model introduced in Sec. 2 First, we describe the time discretization approach, in particular an innovative effective treatment of the multiscale description of the hemodynamics in the OMVS framework (see Section 3.1). Next, we introduce the spatial discretization approach, in particular the Hybridizable Discontinuous Galerkin (HDG) method with an original non-standard Integral Boundary Condition (IBC - see Section 3.2). Finally, we briefly present the open-source computational framework in which the numerical methods are implemented.
3.1 |. Time discretization
First, for what concerns the time approximation of the biomechanics problem, namely systems (7) and (8), we adopt a standard BDF2 approach, see for instance48 Chapter 5.
Next, we focus on the hemodynamics problem and provide details about an innovative method we adopted to address the time discretization of this multiscale system. The main challenge is to numerically solve in an efficient manner the system describing the 3D lamina cribrosa hemodynamics in the domain and the ocular posterior vasculature hemodynamics described by the network model represented in Fig. 4 and denoted hereafter . Note that the problem involves several nonlinearities, for instance the interaction between IOP/RLTp and the blood pressure within the CRA and CRV (Eqs. (1) and (2)).
On the one hand, recall that the system of PDEs (6) in is endowed with the boundary conditions specified in Eqs. (9a), (9b) and (9c), and accounts for the condition expressed in Eq. (10). On the other hand, the circuit can be uniquely described in a generic manner by the following non linear system of ODEs:
| (12) |
with the initial conditions . If is the number of unknowns of the circuit, i.e. the number of ODEs to be solved, is a -dimensional vector representing the state variables of the circuit is a tensor including the topology and physics of the connections among the circuit nodes, and is composed by sources and sinks within the circuit, and by the contribution due to the coupling with the PDE region . In addition, the conservation of flux between the 3D and the 0D is given by
| (13) |
where is the outward flux from the domain is the pressure at the interface and is the unknown pressure at the entrance of the lamina cribrosa in the network (see Fig. 4). As such, is part of the unknown vector .
Let with the time-discretization step. We introduce the notation for the pressure in the 3D domain and the vector of unknowns in the circuit :
In particular, we rewrite as
| (14) |
to highlight the crucial role played by the unknown in the subsequent algorithm:

Note that Steps 1 and 2 are defined on the discrete time interval , but the differential operators have yet to be fully discretized in time and space.
In this work, we adopted a partitioned approach for the numerical solving of the multiscale problem, in order to preserve the modular structure of the OMVS framework and in the perspective of potential extensions that would imply changes limited to each building block. Thus, the communication between the two steps is only realized through the initial conditions and the proposed effective strategy allows notable flexibility in the choice of solution methods for each sub-problem resulting from this specific algorithm. However, the design of the two steps and in particular solving the PDE system jointly with the condition of the conservation of the fluxes (Eq. (13)) in Step 2, is meant to preserve an implicit treatment of the multiscale connection.
Remark 3. Other partitioned strategies could be alternatively employed to numerically solve the multiscale system under consideration in this contribution. One possibility, referred to as functional iterations, or fixed-point (Picard) iteration is to design a strategy based on sub-iterations between PDE and ODE solvers at each time step. Another approach addressing the need to solve in separate sub-steps the PDE and the ODE problem in based on operator splitting. An extensive discussion about the attractive features of these strategies and their limitations in the context of the coupling between a poroelastic medium and a lumped hydraulic circuit can be found in49. The implementation of such approaches and a thorough analysis of their potential advantages in the present context raises interesting questions and might be considered as future research directions.
The computational framework relies on the open-source finite element library Feel++50, in which the global discretization procedure was implemented. Feel++ is a Finite Element Embedded Library in C++ that allows using a very wide range of Galerkin methods, as well as other advanced numerical methods such as domain decomposition methods or certified reduced basis. The ingredients of the software include a very expressive embedded language, seamless interpolation, mesh adaption and seamless parallelization. The first step was implemented within OpenModelica51, an open-source Modelica-based modelling and simulation environment intended for industrial and academic studies of complex dynamic systems. The multiscale connection between the different components of the solver is handled thanks to the capabilities of the Feel++ library. As for the spatial discretization, the splitting approach provided by Algorithm I is very flexible, allowing for different methods. Our specific choice in the present work is the Hybridizable Discontinuous Galerkin method, as described in the next section.
3.2 |. Spatial discretization
In this section we briefly present the Hybridizable Discontinuous Galerkin (HDG) method applied for the spatial discretization of the model, which was originally introduced in this context in15. The rationale for adopting this discretization approach is the high accuracy that all the model solvers require to reproduce physiological behaviors. Specifically, the advantages of HDG are that:
the equation are enforced element-by-element leading to local conservation properties;
the optimal convergence properties for both primal (potential and displacements) and dual (stresses and fluxes) variables are ensured; in particular fluxes are crucial in the communication between the micro- and macroscale.
However, these features induce a significant computational cost, which can be largely mitigated using static condensation as described in15 Section 4.2.
Remark 4. The use of HDG formulation combined with IBC () supports the direct solution of the pressure by means of a natural coupling between the 3D and the OD parts of the model, without any sub-iteration.
The main technical details of this approach are provided in Appendix A, where we report the formulation for the elasticity and the porous media model, which were not detailed in the original paper15. The final forms of the hemodynamics and biomechanics systems, obtained from the static condensation algorithm, are expressed in terms of the potential or the displacement, respectively. Potential and flux - or displacement and stresses for elasticity - are then computed element wise at higher order in a post processing step. For the present application, this property is fundamental, since it provides the same level of accuracy for the primal variables (potential and displacements) and for the dual unknowns, fluxes and stresses of notable interest here.
The overall discretization procedure is again implemented in the Feel++ library50. Numerically the problem is solved by means of domain decomposition methods, in parallel, using an algebraic multigrid solver for both Darcy and elasticity systems; more details are available in15.
Ethical statement:
not applicable
4 |. OMVS INPUT DATA
The purpose of this section is twofold: (i) first, we describe the pipeline we developed to generate a realistic computational mesh of the entire human eye; (ii) second, we provide a thorough description of the input parameters of the OMVS and the main rationale behind our choices. We emphasize the important role of the information described in this section in view of the reproducibility of our work.
4.1 |. Geometry and mesh
In this subsection we present the process we developed to generate a realistic geometry and the associated computational mesh used for the 3D biomechanics and hemodynamics simulations of the tissues represented in the OMVS. This geometry is parameterized on patient-specific inputs, such as the distance between the cornea and the lamina cribrosa and some lamina cribrosa features as described in Table 1 Patient-specific geometrical inputs could be relevant in several clinical contexts, such as: (i) higher risk factors for glaucoma among people of African descent (AD) when compared to European descent (ED), due to differences in their ocular structures (thinner corneas52 and thinner sclera and lamina cribrosa53 for the former compared to the latter); (ii) dynamic changes taking place in the anterior segment with aging, suggesting prevalence of angle closure glaucoma increased in females after middle age54 or (iii) structural changes in patients affected by myopia55.
TABLE 1.
Geometrical parameters that can be modified by the user during the generation of the computational mesh.
| Parameter | Default value | Description |
|---|---|---|
| hsize_lamina | 0.05 | max size of the mesh grid for the lamina cribrosa sub-domain |
| hsize_eye | 1.0 | max size of the mesh grid for all the eye except the lamina cribrosa sub-domain |
| distance | 0.25 mm | lamina cribrosa distance from retina/sclera |
| width | 0.2 mm | lamina cribrosa width |
| hole | 0.2 mm | radius of the lamina cribrosa hole |
| shift | 0.3 mm | hole shift from lamina cribrosa center |
| eye_length | 26.1 mm | ocular axial length |
| corneal_thickness | 1.0 | corneal thickness proportion with respect to the original cAD thickness |
The generation of the geometry and the mesh is realized via the software Salome56, which is an integration platform for numerical simulations with pre- and post-processing tools. We specifically utilized the CAD (Computer Aided Design) module, which is based on OpenCascade57 and its constructive solid geometry features. In the following we briefly describe the main steps of the pipeline we designed to obtain a computational mesh of the eye starting from a CAD image (as schematically illustrated in Fig. 12).
FIGURE 12.

Process to generate a computational mesh from a CAD drawing using the Salome platform.
Geometry
The starting CAD image of the eye is illustrated in Fig. 12a (courtesy of CEMOSIS‡). This preliminary image is imported in Salome, where the following 3D ocular structures are identified: cornea, vitreous humor, iris and ciliary body, ligament, lens, sclera, choroid, retina, central retinal vein and artery. Furthermore, we added the lamina cribrosa representation, motivated by the special role that this tissue plays in the onset and progression of glaucoma20. On the basis of the ocular anatomy description extracted from58, we created a lamina cribrosa geometry within the imported ocular framework. In the generation of the geometry, we made some specific parameters accessible and changeable by the user, as described in Tab. 1. A cut of the newly created geometry of the eye is displayed in Fig. 12b.
Mesh
The mesh module in Salome is used to generate 1D/2D/3D meshes. In particular we employed the NETGEN meshing plugin59 to specify the parameters of the mesh and eventually build the mesh. We set markers on every volume or surface of the structured mesh allowing simulations that can be run only on single parts of the eye or on the whole geometry. Fig. 13a displays the cut along the z-plane of the overall computational mesh, while Fig. 13b shows the generated computational mesh for the lamina cribrosa.
FIGURE 13.

Mesh of the eye realized with Salome using NETGEN algorithms.
In summary, from a CAD of the whole eye we developed a parameterized ocular geometry in order to generate a complex computational mesh, with the following characteristics:
5 sub-domains: ;
20 boundaries and interfaces, with conforming elements at edges and at interfaces;
specific discretization for the lamina cribrosa due to its different geometrical dimensions with respect to the other components.
This generating process has addressed the goal of having a full realistic description of the ocular architecture, which is used by the OMVS for patient-specific numerical simulations. For the entire process and in the case of default values, the code takes a total time of 272.6s, of which 186.1 for the geometry and 84.7 for the mesh.
4.2 |. Model parameters
In this subsection we report all the baseline values for the parameters employed in the OMVS. The selection was made in such way that, at baseline, the model predictions agree with values reported in the literature. Some of the parameters were directly measured or extracted from literature, whereas others were not readily available and thus are indirectly inferred from accessible data, under clinical hypothesis, which will be indicated when relevant. In addition, whenever pertinent, a brief discussion on the measurement instruments to obtain or estimate these parameters is presented.
We remark that parameters choices and calibration is well-recognized as a very delicate problem in the context of mathematical modelling in medicine. On the one hand, as explained above, suitable data to feed the models might be difficult or even impossible to be measured directly. On the other hand, they usually suffer from high variability due to (i) operator-dependent and instrument-dependent measurements, which can be different across clinical centers and (ii) inherent differences among individuals. To take into account these sources of uncertainty and variability, we refer to the preliminary sensitivity analysis we carried out in18 for the 0D components of the OMVS.
We divide the set of parameters of the proposed ocular mathematical model in three groups: (i) parameters common to both the ODE-based and the PDE-based systems, called hereafter global OMVS parameters, (ii) specific parameters employed only in the 3D hemodynamical and biomechanical description of the model, and (iii) specific parameters related to the 0D hemodynamical part.
Global OMVS parameters
First, we focus on the systemic parameters, namely the heart rate (HR), the systolic blood pressure (SP), and the diastolic blood pressures (DP), that can be easily measured with standard non-invasive devices. Specifically, blood pressure is measured with a sphygmomanometer, a clinical instrument which typically consists of an inflatable rubber cuff that is applied to the arm and connected to a column of mercury next to a graduated scale, enabling the determination of SP and DP by increasing and gradually releasing the pressure in the cuff. With the help of a stethoscope, the reading of the HR is easy and noninvasive.
Second, the parameters pertaining to the ocular region described in the model are the IOP, and the RLTp. Recall that IOP is the pressure of the fluids inside the eye and it is determined by the balance between the production and the drainage of aqueous humor. Its value can be obtained non-invasively in a standard clinical setting with the Goldmann Applanation Tonometer, which measures the force necessary to flatten an area of the cornea and computes the pressure exploiting the Imbert-Fick law60. The RLTp is the pressure within the optic nerve tissue, behind the lamina cribrosa. This pressure is largely determined by the pressure within the subarachnoid space, i.e. the intracranial pressure (ICP)32. ICP is usually measured with a lumbar puncture, an invasive technique in which a needle is inserted into the spinal canal to collect cerebrospinal fluid (CSF). However, some recent clinical works61,62 and mathematical models63, propose innovative methods in order to estimate ICP noninvasively. The baseline values for the global parameters are reported in Tab. 2.
TABLE 2.
OMVS global parameters.
| Parameter | Value | Unit | Reference |
|---|---|---|---|
| HR | 69 | beats/min | 64 |
| SP | 120 | mmHg | 30 |
| DP | 80 | mmHg | 30 |
| IOP | 15 | mmHg | 30 |
| RLTp | 7 | mmHg | 30 |
HR=Heart Rate, SP=systolic blood pressure, DP=diastolic blood pressure, IOP=Intraocular pressure, RLTp=Retrolaminar tissue pressure.
3D hemodynamics and biomechanics parameters for the OMVS
Here we describe the baseline parameters values related to the 3D modelling of the OMVS.
The baseline permeability coefficient of the lamina cribrosa and the baseline Lamé coefficients for the different ocular tissues are reported in Tab. 3 In particular we recall that for the lamina cribrosa we have adopted the isotropic hypothesis (Fig. 6b) for the permeability tensor which takes into account for capillaries within the tissue of the lamina. This hypothesis provides a satisfactory approximation of physiological conditions as confirmed by experimental studies47. The majority of the Lamé coefficients values have to be considered valid in case of small stresses 0.0 − 8.0 kPa (≈ 0 – 60 mmHg), see68, which includes the physiological range of pressures involved in the realistic framework developed in the present work.
TABLE 3.
3D parameters for the OMVS.
To complete the set of parameters involved in the 3D model, we consider as baseline value in Eq. (9a) and as baseline value in Eq. (11c). These values have been retrieved from30 in the case of baseline systemic blood pressure of and , as in Tab. 2 For the different validation cases for which we report simulations in the next section we have calibrated the values of and with a similar approach, namely directly proportional to the values of SP and DP. Thus, every time the values of SP and DP are modified from their baseline values, also and are changed accordingly.
Regarding available measurements in this context, the utilization of Optical Coherence Tomography Angiography offers valuable insights about crucial dimensions, thickness, and vessel structure of the lamina and retina74,75. Additionally, the pachymeter serves as a precise tool for obtaining Central Corneal Thickness measurements. In terms of material properties, our focus turns to ultrasound elastography, a technique that holds promise in this domain. Moreover, we point to a rich reservoir of ocular biomechanics literature, particularly highlighting ex-vivo measurements and traction tests supported by advanced mathematical analysis76,77,78.
0D hemodynamics parameters for the OMVS
In this paragraph we define the baseline parameter values for the 0D component of the OMVS. The resistances and the capacitances baseline values are reported in Tabs. 4 and 5, respectively, together with the corresponding references from which they were extracted. In the particular case of nonlinear resistors, the values are computed using Eqs. (1) and (2), respectively.
TABLE 4.
Summary of the data for the resistors in the 0D hemodynamics model.
| Name | Parameters | Values | Units | Reference |
|---|---|---|---|---|
| R | 22500 | mmHg s cm−3 | 30 | |
| 2.124 · 10−4 | cm3 mmHg−1 s−1 | 31 | ||
| 55.714 | [-] | |||
| 24.665 | mmHg | |||
| RLTp | mmHg | |||
| 2.107 · 10−4 | cm3 mmHg−1 s−1 | 31 | ||
| 55.487 | [-] | |||
| 24.816 | mmHg | |||
| RLTp | mmHg | |||
| 0.0047 | cm3 mmHg−1 s−1 | 31 | ||
| 56.1468 | [-] | |||
| 24.3797 | mmHg | |||
| IOP | mmHg | |||
| 0.0010 | cm3 mmHg−1 s−1 | 31 | ||
| 56.1785 | [-] | |||
| 24.3591 | mmHg | |||
| IOP | mmHg | |||
| R | 6000 | mmHg s cm−3 | 31 | |
| R | 6000 | mmHg s cm−3 | 31 | |
| R | 5680 | mmHg s cm−3 | 31 | |
| R | 5680 | mmHg s cm−3 | 31 | |
| 2.199 · 10−4 | cm3 mmHg−1 s−1 | 31 | ||
| 992.4853 | [-] | |||
| 0.0722 | mmHg | |||
| IOP | mmHg | |||
| 2.199 · 10−4 | cm3 mmHg−1 s−1 | 31 | ||
| 992.4853 | [-] | |||
| 0.0722 | mmHg | |||
| IOP | mmHg | |||
| 0.0031 | cm3 mmHg−1 s−1 | 31 | ||
| 1457.5 | [-] | |||
| 0.3687 | mmHg | |||
| IOP | mmHg | |||
| 0.0156 | cm3 mmHg−1 s−1 | 31 | ||
| 1458.2 | [-] | |||
| 0.3684 | mmHg | |||
| IOP | mmHg | |||
| 0.0007 | cm3 mmHg−1 s−1 | 31 | ||
| 1419.4 | [-] | |||
| 0.3836 | mmHg | |||
| RLTp | mmHg | |||
| 0.0007 | cm3 mmHg−1 s−1 | 31 | ||
| 1424.1 | [-] | |||
| 0.3817 | mmHg | |||
| RLTp | mmHg | |||
| R | 14111.39 | mmHg s cm−3 | 30 | |
| R | 78181.9 | mmHg s cm−3 | 66 | |
| R | 21988.25 | mmHg s cm−3 | 66 |
TABLE 5.
Summary of the data for the capacitors in the 0D hemodynamics model.
Finally, we characterize the blood pressure source and sink within the circuit in a consistent manner with experiments. For , we employed the same approach as in30: we reconstruct the pressure profile at the entry of the circuit (see Fig. 4 from typical Color Doppler Imaging (CDI) measurement of the blood velocity in the CRA and we impose it as a time-dependent pressure source (see Fig. 14). The CDI employs the Doppler effect to generate imaging of the movement of tissues and body fluids - usually blood - and their relative velocity to the probe by calculating the frequency shift of a particular sample volume. We parametrize the reconstructed signal using HR, SP and DP as inputs; thus, we have divided this blood pressure time profile into 6 parts for each cardiac cycle, as follows:
| (15) |
where . Regarding , we set its baseline value to 14 mmHg, as reported in30.
FIGURE 14.

Color Doppler Imaging (CDI) blood velocity profile within the CRA. Courtesy of the Eugene and Marilyn Glick Eye Institute (Indianapolis, USA).
For the retinal blood flow another quantity that the ophthalmologist can measure is the oxygenation of the blood by means of the retinal oxymetry79, however for the current implementation of the OMVS, this measurement is not exploited.
5 |. OMVS VALIDATION
In this section we discuss several significant outcomes of the OMVS and compare our simulations with clinical or experimental data whenever available. The aim is to provide a thorough validation for the OMVS framework and to complement predictive results previously published in80,17. The verification of the numerical methods presented in Sec. 3 has been already extensively performed in 15.
Fig. 15 displays all the output available within the OMVS and lists the main sources where we retrieved the experimental data. The section is organized as follows:
FIGURE 15.

Overview of the OMVS validation: comparison with experimental data.
validation of the hemodynamics simulated by the OMVS;
validation of the biomechanics of the lamina cribrosa simulated by the OMVS;
validation of the biomechanics of other ocular tissues represented in the OMVS.
Note that the intrinsic physiological variability makes validation a very challenging task; thus we strive to report both qualitative and quantitative comparisons with experimental data whenever the latter ones are possible. Furthermore, we highlight the fact that for the hemodynamics within the lamina cribrosa, to the best of our knowledge, there are no experimental or clinical data, thus we cannot directly validate the simulation results; however, since all the system components are strongly coupled we consider that if all the other parts reproduce a physiological behavior, also the lamina cribrosa perfusion computed by the OMVS should attain realistic values.
5.1 |. Hemodynamics of the ocular posterior segment
In this part we discuss the outcome concerning the central retinal vessels hemodynamics, which are part of the circuit presented in Sec. 2.1 and in the lamina cribrosa, as described in Sec.2.2.
First, we obtained similar numerical results as reported in30. Despite the numerous simplifying assumption in the simple 0D scheme, indeed, the proposed mathematical model is able to capture the mechanical action of IOP on clinically measurable hemodynamics quantities, in particular the CRA blood velocity. In particular Guidoboni et al. report a peak systolic CRA flow of and an end distolic CRA flow of for a patient with normal IOP and high blood pressure, values which are in good agreement with our results for the HBP - Normal IOP case (110.58 and , respectively). Therefore their conclusions can be extended also to the present model. The model predicts that the steep decay in retinal blood flow that occurs due to high IOP would shift toward higher values as the blood pressure of the subject increases. This outcome also agrees with the clinical study of He et al.93, who found that a higher IOP was needed to attenuate ocular blood flow in Long-Evans rats with higher systemic blood pressure.
Second, in another set of simulations, we utilize the values of IOP, HR, SP, and DP reported in81 as input data of the OMVS and compare the predictions of the simulation (Fig. 16) with the clinical results provided in81. We have simulated three test cases of clinical interest:
systemic hypertensive subjects (HBP) with high IOP;
system hypertensive subjects (HBP) with normal IOP;
normal systemic blood pressure subjects (NBP) with high IOP.
Input values are listed in Tab. 6.
FIGURE 16.

OMVS validation study: hemodynamics of the CRA/CRV and lamina cribrosa. Input data retrieved from81.
TABLE 6.
Input data for the comparative study with81.
| Test case | SP[mmHg] | DP[mmHg] | HR[beats/min] | IOP[mmHg] |
|---|---|---|---|---|
| HBP - High IOP | 170 | 100 | 60 | 28 |
| HBP - Normal IOP | 170 | 100 | 60 | 15 |
| NBP - High IOP | 139.2 | 82.4 | 60 | 28 |
Fig. 16a shows the blood flow profile during two cardiac cycles computed by the OMVS within the CRA and CRV. Note that the CRV flow has a negative sign to indicate its opposite direction with respect CRA flow, the same convention used in clinical settings for CDI (see Fig. 14). Systemic hypertensive virtual subjects share a similar blood flow waveform within the CRA (red and blue solid lines), whereas the model predicts a lower CRA blood flow for NBP - High IOP subjects (black solid line). For what concerns the CRV, the simulation results for virtual subjects with elevated IOP (blue and black dashed lines) show a drop in the blood flow with respect to HBP - Normal IOP (red dashed line). This reduction lasts longer in the case of NBP - High IOP (black dashed line).
The top panel of Fig. 16b displays the lamina cribrosa pressure drop between its external and internal boundaries during one cardiac cycle. The bottom panel of Fig. 16b reports the lamina cribrosa perfusion value on during one cardiac cycle. Fig. 16b suggests that HBP - Normal IOP subjects (red line) experience a similar hemodynamic behavior as HBP - High IOP subjects (blue line), whereas NBP - High IOP subjects (black line) exhibit a significant drop in the lamina cribrosa pressure and perfusion (up to 28% in both cases). These outcomes are easily identifiable also qualitatively from Fig. 16c where we display the 3D spatial distribution of the blood pressure accompanied by the intensity of the blood perfusion (color-coded arrows within the domain). The clinical results reported by Costa et al.81 suggest that only individuals with high IOP and normal blood pressure may be at higher risk for glaucomatous damage. The model predictions of the OMVS conjecture that elevated IOP has a significant impact on the lamina cribrosa hemodynamics when combined with normal systemic blood pressure, whereas it is remarkably less noticeable in case of high systemic blood pressure. Considering that a deficit in the lamina cribrosa perfusion as a risk factor for glaucoma, which is an increasingly supported idea in ophthalmology94,95, the simulation results obtained employing our mathematical model are consistent with the clinical analysis presented above. In addition, we also compared our results with experimental data from a quantitative viewpoint. In particular, we refer to the values of the CRA blood flow at peak systole, end diastole and mean reported by Harris et al.83, Riva et al.84, and Dorner et al.82, which are in good agreement with the present simulation outcomes (see Tab. 7).
TABLE 7.
CRA flow comparison with experimental data using the hypothesis of CRA diameter of 82.
Third, these theoretical predictions on the relationship between intraocular pressure, blood pressure, ocular perfusion and glaucoma have been confirmed by the Singapore Epidemiology of Eye Diseases study, an independent population-based study including nearly 10000 individuals85.
5.2 |. Biomechanics of the lamina cribrosa
We focus in this part on the OMVS outcomes related to the biomechanics of the lamina cribrosa.
First, Guidoboni et al.33 compared the simulation results with experimental measurements96,97 suggesting that the biomechanics in the lamina has a significant impact also on the hemodynamics in the central retinal vessels. In a previous study98 (results not reported in detail here) we performed a similar virtual experiment that investigates the effect of IOP on the biomechanics and hemodynamics within the lamina cribrosa. The results obtained employing the OMVS were consistent with the findings reported in33.
Second, Causin et al.65 reported results on two different modeling case studies and comparisons with experiments conducted by Yan et al.88, who mounted three enucleated human eyes on a specially designed experimental apparatus, which allowed to sequentially increase the IOP. We replicated this experiment virtually using the OMVS, completing 5 tests with increasing IOP values of 5, 15, 25, 35 and 50 mmHg, respectively. According to data reported in65 and88, for all virtual tests we considered the following inputs
Fig. 17a shows the deformed 3D geometry of the lamina cribrosa for the 5 different input values for the IOP, using the one corresponding to IOP = 5mmHg as the reference value (in gray). On this basis, we next computed the LC volume below reference, namely , and we compared our 5 simulations with the measurements using three enucleated human eyes (eyeA, eyeB, eyeC)88 and the results provided by65 in the two modeling test cases (Causin-case1, Causin-case2). The results displayed in Fig. 17c show that the values of predicted by the OMVS fall within the range of values measured experimentally in88 and theoretically predicted in65. In addition, the LC maximum displacement at baseline with is within the range of values reported by the experimental studies of Yan et al.87 . Fig. 17b is an the example of the 3D spatial distribution LC displacement at baseline , showing that the LC biomechanics is only mildly influenced by the presence of the CRA/CRV opening. Interestingly, this effect has been reported in a previous optic nerve head biomechanics study86.
FIGURE 17.

OMVS validation study: biomechanics of the lamina cribrosa.
5.3 |. Biomechanics of cornea, sclera, choroid and retina.
In this subsection we discuss the biomechanical simulations provided by the OMVS for other ocular tissues than the lamina cribrosa, and their relevance when compared with real data.
As a premise, we emphasize the fact that few works have been done in this direction. Indeed, the possibility to measure the stresses and the displacements experienced by retina, choroid, sclera and cornea in vivo is very challenging; on the other hand, many studies tried to replicate the behavior of such tissues with phantoms or ex vivo experiments. For this reason, we have compared the simulations results of the sclera and the cornea, which are the external and more accessible tissues, whereas for the biomechanics of the retina and choroid we plan to conclude this exhaustive analysis when more data will be available in the future. For all test cases we have used the 3D OMVS parameters presented in Tab. 3 and the following input data
First, we refer to the work by Myers et al.92, where the authors are performing an inflation test on a posterior bovine sclera. This in vitro analysis exhibits a nonlinear response to controlled pressurization. We completed 3 virtual experiments with increasing IOP values of 14.78, 23.3 and 30 mmHg, respectively. Myers et al. reported that the sclera can be modeled as a quasi-linear elastic material in the physiological pressure range of 2 – 6kPa (≈ 15 – 45 mmHg), behavior which is well replicated by our virtual experiments resumed in Fig. 18a The colormap of the 3D overview of the scleral displacement in Fig. 18b shows a larger deformability of the optic nerve head area, coherently with the work of Myers et al.92.
FIGURE 18.

OMVS validation study: biomechanics of the sclera and cornea. Dotted lines represent the ideal linear behaviour.
Second, we refer to the correlation between axial length and intraocular pressure discussed in the work by Detorakis and Pallikaris90. The axial length is the distance between the cornea and the back of the retina. It is the combination of the depth of the anterior chamber, the lens and the vitreous humor chamber. In adults, it measures between 22 and 25 mm99. In this case, we have performed 6 virtual experiments with increasing IOP values of 1.5, 3.83, 10.5, 14.78, 23.3 and 30 mmHg, respectively. The authors infer a linear dependency between the measurements of intraocular pressure and axial length. The results provided by the OMVS (Fig. 18c) are in good agreement with such a correlation between these two quantities and within the range of measurements in adults.
Third, we compare the model predictions of the OMVS with the findings of Boyce et al. 89 on the corneal displacement. In their study, the authors have conducted experiments on a bovine cornea to measure the displacement under constrained inflation conditions. We conducted 6 virtual experiments with increasing IOP values of 1.5, 3.83, 10.5, 14.78, 23.3 and 30 mmHg, respectively. Boyce et al. found that, if the IOP applied on the cornea is in physiological ranges, the displacement has a linear behavior (Figs. 7, 9 and 10 of89). Our model predicts a similar behavior for the human cornea, as illustrated in Fig. 18d. This linear behavior is well captured by the OMVS, despite the presence of several nonlinearities in the biomechanical interaction between the ocular tissues and in the hemodynamics of the ocular posterior segment. Furthermore, Fig. 18d reports a maximum corneal displacement up to 0.03 cm, which is consistent with the values reported by Elsheikh et al.91.
6 |. CONCLUSIONS
The main goal of the current study was to design the Ocular Mathematical Virtual Simulator, a mathematical and computational framework able to simulate and predict the biomechanics and hemodynamics within the main tissues of the eye. Advanced and innovative numerical methods were developed to take into account (i) the combined effects of flows and different structures from a multiphysics perspective, and (ii) the interplay between local and systemic effects on the blood flow inherent to the multiscale structure of the problem. The proposed results provide an extensive validation of the model, that paves the way for its utilization in the context of clinical research for glaucoma. By comprehensively modeling the lamina cribrosa’s and the surrounding tissues behavior under varying conditions100,16,98,17, our framework could aid in predicting and understanding the hemodynamical and biomechanical changes associated with glaucomatous damage. This, in turn, may contribute to improved diagnostic and treatment strategies, enhancing patient care.
Some hypotheses, however, had been incorporated in the development of the OMVS, which lead to some limitations for its use. First, the retina has been considered as an elastic tissue from the biomechanics standpoint and represented by a 0D model for the hemodynamics. Alternatively, a porous media model could have been used to describe blood flow dynamics in this tissue, similarly to the lamina cribrosa. However, the internal retinal vasculature is more complex than the lamina cribrosa and it is not fully understood yet101. Moreover, the images that can be obtained on the retina are mostly reduced to a small portion of the total tissue, usually the fundus, which is the part close to the optic nerve head. Second, the present configuration of the OMVS does not incorporate the effect of the vitreous humor and only accounts for a steady description of the aqueous humor, in which the IOP value is considered constant. As a further step, and thanks to the modularity of the OMVS design, other models developed to describe the vitreous humor102, the aqueous humor and the IOP modeling103 could be integrated in the proposed framework. Third, further investigation into uncertainty quantification should be undertaken to comprehensively gauge the level of confidence associated with the obtained results and understand the robustness of the OMVS framework. Fourth, although our primary emphasis remains the investigation of glaucoma, it is conceivable that a comparable approach could be extended to provide insights into other ocular pathologies, including Age-Related Macular Degeneration, Diabetic Retinopathy, or other neurodegenerative diseases80. Nevertheless, for the model to offer substantial insights into these diverse conditions, it would necessitate overcoming certain limitations outlined earlier. Furthermore, its clinical significance in those areas would necessitate dedicated research efforts and validation specific to those conditions.
In conjunction with this, the incorporation of machine learning techniques also presents considerable promise in the advancement of sophisticated models for ocular diseases. It has the potential to enrich our comprehension of diverse ocular pathologies by meticulously analyzing extensive datasets, as recently reviewed for instance in104, see also105,106. Furthermore, the combined use of mathematical modeling and artificial intelligence may help progressing personalized research in ophthalmology.
ACKNOWLEDGMENTS
This work has been partially supported by the Ministère de l’Enseignement supérieur et de la Recherche (France), the Center for Modeling and Simulation in Strasbourg (Cemosis) and it has received funding from the European Union’s Horizon 2020 research and innovation program under grant agreement No. 731063. Professor Giovanna Guidoboni has been partially supported by NSF DMS 2108711/2327640 and NIH R01EY034718. Professor Alon Harris is supported by NIH grants (R01EY030851 and NIH R01EY034718), NYEE Foundation grants, and in part by a Challenge Grant award from Research to Prevent Blindness, NY. Professor Giovanna Guidoboni would like to disclose that he received remuneration from Qlaris and Foresite Healthcare serving as a consultant. All relationships listed above are pursuant to UMaine’s policy on outside activities.
Professor Alon Harris would like to disclose that he received remuneration from AdOM, Qlaris, and Cipla for serving as a consultant, and he serves on the board of AdOM and Qlaris. Professor Alon Harris holds an ownership interest in AdOM, Oxymap, Qlaris, and SlitLed. All relationships listed above are pursuant to Icahn School of Medicine’s policy on outside activities.
APPENDIX A
In this appendix we describe the main steps of the HDG method utilized in the OMVS framework, based on15. We first introduce the general framework and its notations, then specify our approach to the hemodynamics in the lamina cribrosa (Eq. (6)), and finally to the biomechanics described by systems (7) and (8).
Introductory notation
In view of the finite element approximation, we partition with into the union of closed straight tetrahedra , and we denote by - called triangulation - the collection of elements such that . For each , we denote by the diameter of . We let and we consider a family of conforming, regular triangulations of (see48 Chapter 3). For each element we indicate by the boundary of and by the associated outward unit normal vector. The 3-dimensional measure of the element is indicated with while the 2-dimensional measure of each face of is denoted by .
We let denote the collection of all the faces of , whose union forms the skeleton of the decomposition . The set naturally splits into the subset of faces belonging to , and into the subset of faces belonging to the interior of , denoted by . Finally, assuming that the decomposition is such that for all faces in with either or , the sets of boundary faces can be split into the subsets , and , which correspond to the boundaries where we impose Dirichlet, Neumann and Integral condition, respectively. Let us now introduce the finite element spaces
| (16a) |
| (16b) |
with defined as
and with
| (17) |
where (resp. ) denotes the space of polynomials of degrees less or equal that on (resp. ). Definitions (16a), (16b) and (17) imply that functions belonging to and are, in general, discontinuous across elements faces of , while functions in are discontinuous across element edges of , single-valued on each face of the skeleton of and constant on . The functions of play the role of “connectors” between adjacent elements enabling the possibility to use static condensation to reduce the computational cost. To simplify the presentation, we introduce the compact notations for the integrals:
Porous media model
We now consider the elliptic boundary value problem of second order described in Eq. (6). At the discrete level, in the numerical normal flux is defined as
| (18) |
where the quantity is a non-negative stabilization parameter. The HDG formulation then reads: find and such that
where
and and are the associated Neumann and Dirichlet boundary conditions described in Sec. 2.4. The dependent variables and are the approximations of and in the interior of each element , whereas the dependent variable is the approximation of the trace of on each face of . The numerical normal flux (18) is characteristic of a particular class of HDG methods, the so-called Local Discontinuous Galerkin Hybridizable (LDG-H) methods proposed and investigated in a series of seminal papers (see107 and references therein).
Linear elasticity model
In this paragraph we apply the HDG method to the linear elasticity equations (Eqs. (7) and (8)).
In addition to the notation introduced in the previous part, we define on for the stabilization parameter and the -orthogonal projection from onto , denoted such that:
| (19) |
The use of is needed in order to obtain the optimal accuracy; without it, the formulation might result slightly less accurate108. Thus, we write the HDG formulation for linear elasticity: find and such that and
where
with defined as
and and are the associated Neumann and Dirichlet boundary conditions described in Sec. 2.4. Observe that (i) the spaces introduced in this paragraph are the natural extension of the spaces needed for the porous media system, and (ii) the symmetry for elements is enforced in an essential manner in their definition108.
□
Footnotes
The formula used is peak systolic flow end diastolic flow
CEnter for MOdeling and SImulation in Strasbourg. http://www.cemosis.fr/
References
- 1.Updegrove A, Wilson NM, Merkow J, Lan H, Marsden AL, Shadden SC. SimVascular: an open source pipeline for cardiovascular simulation. Annals of biomedical engineering 2017; 45(3): 525–541. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Arthurs CJ, Khlebnikov R, Melville A, et al. CRIMSON: An open-source software framework for cardiovascular integrated modelling and simulation. PLOS Computational Biology 2021; 17(5): e1008881. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Mut F, Löhner R, Chien A, et al. Computational hemodynamics framework for the analysis of cerebral aneurysms. International journal for numerical methods in biomedical engineering 2011; 27(6): 822–839. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Mardal KA, Rognes ME, Thompson TB, Valnes LM. Mathematical Modeling of the Human Brain: From Magnetic Resonance Images to Finite Element Simulation. 2022.
- 5.Africa PC.: A flexible, high performance library for the numerical solution of complex finite element problems. SoftwareX 2022; 20: 101252. [Google Scholar]
- 6.https://gitlab.inria.fr/felisce/felisce..
- 7.Guidoboni G, Nunez R, Keller J, et al. Precision medicine and glaucoma management: how mathematical modeling and artificial intelligence help in clinical practice. Expert Review of Ophthalmology 2022; 17(5): 299–301. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Zhu L, Zheng Y, Von Kerczek C, Topoleski L, Flower R. Feasibility of extracting velocity distribution in choriocapillaris in human eyes from ICG dye angiograms. 2006. [DOI] [PubMed]
- 9.Guidoboni G, Harris A, Sacco R. Ocular fluid dynamics: anatomy, physiology, Imaging Techniques, and Mathematical Modeling. Springer. 2019. [Google Scholar]
- 10.Hernandez RJ, Roberts PA, El-Bouri WK. Advancing treatment of retinal disease through in silico trials. Progress in Biomedical Engineering 2023; 5(2): 022002. doi: 10.1088/2516-1091/acc8a9 [DOI] [Google Scholar]
- 11.Ninos G, Bartzis V, Merlemis N, Sarris IE. Uncertainty quantification implementations in human hemodynamic flows. Computer Methods and Programs in Biomedicine 2021; 203: 106021. [DOI] [PubMed] [Google Scholar]
- 12.Ninos G, Sofiadis G, Skouroliakou A, Sarris IE. A Low-Cost Algorithm for Uncertainty Quantification Simulations of Steady-State Flows: Application to Ocular Hemodynamics. Symmetry 2022; 14(11): 2305. [Google Scholar]
- 13.Gross J, Prada D. Measurement of geometrical and functional parameters related to ocular blood flow. In: Springer. 2019. (pp. 71–99). [Google Scholar]
- 14.Maram J, Srinivas S, Sadda SR. Evaluating ocular blood flow. Indian Journal of Ophthalmology 2017; 65(5): 337. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Bertoluzza S, Guidoboni G, Hild R, et al. A HDG method for elliptic problems with integral boundary condition: Theory and Applications.. Journal of Scientific Computing 2023; 95(6). doi: 10.1007/s10915-023-02109-5 [DOI] [Google Scholar]
- 16.Sala L, Prud’Homme C, Guidoboni G, Szopos M. Ocular mathematical virtual simulator: A hemodynamical and biomechanical study towards clinical applications. Journal of Coupled Systems and Multiscale Dynamics 2018; 6(3): 241–247. [Google Scholar]
- 17.Sala L, Prud’homme C, Guidoboni G, Szopos M, Harris A. Mathematical Assessment of the Role of Three Factors Entangled in the Development of Glaucoma by Means of the Ocular Mathematical Virtual Simulator. In: Springer. 2021. (pp. 851–860). [Google Scholar]
- 18.Prud’Homme C, Sala L, Szopos M. Uncertainty propagation and sensitivity analysis: results from the Ocular Mathematical Virtual Simulator. Mathematical Biosciences and Engineering 2021; 18(3): 2010–2032. [DOI] [PubMed] [Google Scholar]
- 19.https://www.biorender.com..
- 20.Harris A, Guidoboni G, Siesky B, et al. Ocular blood flow as a clinical observation: Value, limitations and data analysis. Progress in retinal and eye research 2020; 78: 100841. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Downs JC, Roberts MD, Burgoyne CF, Hart RT. Multiscale finite element modeling of the lamina cribrosa microarchitecture in the eye. In: IEEE.; 2009: 4277–4280. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Sigal IA, Ethier CR. Biomechanics of the optic nerve head. Experimental eye research 2009; 88(4): 799–807. [DOI] [PubMed] [Google Scholar]
- 23.Grytz R, Meschke G, Jonas JB. The collagen fibril architecture in the lamina cribrosa and peripapillary sclera predicted by a computational remodeling approach. Biomechanics and modeling in mechanobiology 2011; 10(3): 371–382. [DOI] [PubMed] [Google Scholar]
- 24.Newson T, El-Sheikh A. Mathematical modeling of the biomechanics of the lamina cribrosa under elevated intraocular pressures. Journal of biomechanical engineering 2006; 128(4): 496–504. [DOI] [PubMed] [Google Scholar]
- 25.Bellezza AJ, Hart RT, Burgoyne CF. The optic nerve head as a biomechanical structure: initial finite element modeling. Investigative ophthalmology & visual science 2000; 41(10): 2991–3000. [PubMed] [Google Scholar]
- 26.Girard MJ, Suh JKF, Bottlang M, Burgoyne CF, Downs JC. Biomechanical changes in the sclera of monkey eyes exposed to chronic IOP elevations. Investigative ophthalmology & visual science 2011; 52(8): 5656–5669. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Chuangsuwanich T, Birgersson KE, Thiery A, Thakku SG, Leo HL, Girard MJ. Factors Influencing Lamina Cribrosa Microcapillary Hemodynamics and Oxygen Concentrations. Investigative ophthalmology & visual science 2016; 57(14): 6167–6179. [DOI] [PubMed] [Google Scholar]
- 28.Carichino L, Guidoboni G, Siesky B, et al. Effect of intraocular pressure and cerebrospinal fluid pressure on the blood flow in the central retinal vessels. Integrated Multidisciplinary Approaches in the Study and Care of the Human Eye Kugler Publications 2014: 59–66. [Google Scholar]
- 29.Sacco R, Guidoboni G, Mauri AG. A Comprehensive Physically Based Approach to Modeling in Bioengineering and Life Sciences. Academic Press. 2019. [Google Scholar]
- 30.Guidoboni G, Harris A, Cassani S, et al. Intraocular pressure, blood pressure, and retinal blood flow autoregulation: a mathematical model to clarify their relationship and clinical relevance. Investigative ophthalmology & visual science 2014; 55(7): 4105–4118. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Salerni F, Repetto R, Harris A, et al. Biofluid modeling of the coupled eye-brain system and insights into simulated microgravity conditions. PloS one 2019;14(8). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Morgan WH, Yu DY, Alder VA, et al. The correlation between cerebrospinal fluid pressure and retrolaminar tissue pressure.. Investigative ophthalmology & visual science 1998; 39(8): 1419–1428. [PubMed] [Google Scholar]
- 33.Guidoboni G, Harris A, Carichino L, Arieli Y, Siesky BA. Effect of intraocular pressure on the hemodynamics of the central retinal artery: a mathematical model. Mathematical Biosciences & Engineering 2014; 11(3): 523–546. [DOI] [PubMed] [Google Scholar]
- 34.Cassani S Blood circulation and aqueous humor flow in the eye: multi-scale modeling and clinical applications. PhD thesis. 2016. [Google Scholar]
- 35.Cancelli C, Pedley T. A separated-flow model for collapsible-tube oscillations. Journal of Fluid Mechanics 1985; 157: 375–404. [Google Scholar]
- 36.Shapiro AH. Steady flow in collapsible tubes. Journal of Biomechanical Engineering 1977; 99(3): 126–147. [Google Scholar]
- 37.Biot M, Willis D. The elastic coeff cients of the theory of consolidation. J. appl. Mech 1957; 24: 594–601. [Google Scholar]
- 38.De Boer R Theory of porous media: highlights in historical development and current state. Springer Science & Business Media. 2012. [Google Scholar]
- 39.Coussy O. Poromechanics. John Wiley & Sons. 2004. [Google Scholar]
- 40.Whitaker S The method of volume averaging. 13. Springer Science & Business Media. 2013. [Google Scholar]
- 41.Markert B Porous media viscoelasticity with application to polymeric foams. 2005.
- 42.Showalter RE. Diffusion in poro-elastic media. Journal of mathematical analysis and applications 2000; 251(1): 310–340. [Google Scholar]
- 43.Bociu L, Guidoboni G, Sacco R, Webster JT. Analysis of nonlinear poro-elastic and poro-visco-elastic models. Archive for Rational Mechanics and Analysis 2016; 222(3): 1445–1519. [Google Scholar]
- 44.Recrosi F, Repetto R, Tatone A, Guidoboni G. Thermodynamic derivation of a non-linear poroelastic model describing hemodynamicsmechanics interplay in the lamina cribrosa. Journal for Modeling in Ophthalmology 2018; 2(2): 80–85. [Google Scholar]
- 45.Prada D A hybridizable discontinuous Galerkin method for nonlinear porous media viscoelasticity with applications in ophthalmology. PhD thesis. IUPUI, 2016. [Google Scholar]
- 46.Bociu L, Guidoboni G, Sacco R, Verri M. On the role of compressibility in poroviscoelastic models. Mathematical Biosciences and Engineering 2019; 16(5). [DOI] [PubMed] [Google Scholar]
- 47.Brazile B, Yang B, Gogola A, Lam P, Voorhees A, Sigal IA. One beam-one vessel is not true: lamina cribrosa vessel and collagen beam networks have distinct topologies. Investigative Ophthalmology & Visual Science 2019; 60(9): 4275–4275. [Google Scholar]
- 48.Quarteroni A, Valli A. Numerical Approximation of Partial Differential Equations. Lecture Notes in MathematicsSpringer-Verlag. 1994. [Google Scholar]
- 49.Bociu L, Guidoboni G, Sacco R, Prada D. Numerical simulation and analysis of multiscale interface coupling between a poroelastic medium and a lumped hydraulic circuit: Comparison between functional iteration and operator splitting methods. Journal of Computational Physics 2022; 466: 111379. doi: 10.1016/j.jcp.2022.111379 [DOI] [Google Scholar]
- 50.Prud’Homme C, Chabannes V, Doyeux V, Ismail M, Samake A, Pena G. Feel++: A computational framework for galerkin methods and advanced numerical methods. In:. 38. EDP Sciences.; 2012: 429–455. [Google Scholar]
- 51.Fritzson P, Aronsson P, Lundvall H, et al. The OpenModelica modeling, simulation, and development environment. In: ; 2005.
- 52.Racette L, Boden C, Kleinhandler SL, et al. Differences in visual function and optic nerve structure between healthy eyes of blacks and whites. Archives of ophthalmology 2005; 123(11): 1547–1553. [DOI] [PubMed] [Google Scholar]
- 53.Downs CGMFHYLWBSCCCBJC. Racial variation in the structure of the lamina cribrosa and sclera within 3-D fluorescent reconstructed optic nerve heads (ONH) from normal human donor tissue.. In: ; 2013.
- 54.Lim KJ, Hyung SM, Youn DH. Ocular dimensions with aging in normal eyes. Korean Journal of Ophthalmology 1992; 6(1): 19–31. [DOI] [PubMed] [Google Scholar]
- 55.Markeviciute A, Januleviciene I, Antman G, Siesky B, Harris A. Differences in structural parameters in patients with open-angle glaucoma, high myopia and both diseases concurrently. A pilot study. Plos one 2023; 18(6): e0286019. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56.Ribes A, Caremoli C. Salome platform component model for numerical simulation. In:. 2. IEEE.; 2007: 553–564. [Google Scholar]
- 57.SAS OC. Open CASCADE Technology, 3D modeling & numerical simulation. 2008.
- 58.Prada D, Harris A, Guidoboni G, Rowe L, Verticchio-Vercellin AC, Mathew S. Vascular anatomy and physiology of the eye. In: Springer. 2019. (pp. 23–45). [Google Scholar]
- 59.Schöberl J NETGEN An advancing front 2D/3D-mesh generator based on abstract rules. Computing and visualization in science 1997; 1(1): 41–52. [Google Scholar]
- 60.Ehlers N, Bramsen T, Sperling S. Applanation tonometry and central corneal thickness. Acta ophthalmologica 1975; 53(1): 34–43. [DOI] [PubMed] [Google Scholar]
- 61.Morgan B, Khoo YJ, Kermode A, et al. Utilization of Retinal Vein Photoplethysmography to Measure Intracranial Pressure. Investigative Ophthalmology & Visual Science 2019; 60(9): 5229–5229. [Google Scholar]
- 62.Rantz M, Lane K, Phillips LJ, et al. Enhanced registered nurse care coordination with sensor technology: Impact on length of stay and cost in aging in place housing. Nursing outlook 2015; 63(6): 650–655. [DOI] [PubMed] [Google Scholar]
- 63.Garnotel S, Salmon S, Balédent O. Numerical modeling of the intracranial pressure using windkessel models. MathematicS In Action 2017; 8(1): 9–25. [Google Scholar]
- 64.Bryan S, Larose MSP, Campbell N, Clarke J, Tremblay MS. Resting blood pressure and heart rate measurement in the Canadian Health Measures Survey, cycle 1. Health Reports 2010; 21(1): 71. [PubMed] [Google Scholar]
- 65.Causin P, Guidoboni G, Harris A, Prada D, Sacco R, Terragni S. A poroelastic model for the perfusion of the lamina cribrosa in the optic nerve head. Mathematical biosciences 2014; 257: 33–41. [DOI] [PubMed] [Google Scholar]
- 66.Sala L Mathematical modelling and simulation of ocular blood flows and their interactions. PhD thesis. Université de Strasbourg, 2019. [Google Scholar]
- 67.Causin P, Sacco R. A Discontinuous Petrov-Galerkin Method with Lagrangian Multipliers for Second Order Elliptic Problems. SIAM Journal on Numerical Analysis 2005; 43(1): 280–302. [Google Scholar]
- 68.Woo SY, Kobayashi A, Schlegel W, Lawrence C. Nonlinear material properties of intact cornea and sclera. Experimental eye research 1972; 14(1): 29–39. [DOI] [PubMed] [Google Scholar]
- 69.Friberg TR, Lace JW. A comparison of the elastic properties of human choroid and sclera. Experimental eye research 1988; 47(3): 429–436. [DOI] [PubMed] [Google Scholar]
- 70.Norman RE, Flanagan JG, Sigal IA, Rausch SM, Tertinegg I, Ethier CR. Finite element modeling of the human sclera: influence on optic nerve head biomechanics and connections with glaucoma. Experimental eye research 2011;93(1):4–12. [DOI] [PubMed] [Google Scholar]
- 71.Jones I, Warner M, Stevens J. Mathematical modelling of the elastic properties of retina: a determination of Young’s modulus. Eye 1992; 6(6): 556. [DOI] [PubMed] [Google Scholar]
- 72.Wollensak G, Spoerl E. Biomechanical characteristics of retina. Retina 2004; 24(6): 967–970. [DOI] [PubMed] [Google Scholar]
- 73.Pinsky PM, Heide v. dD, Chernyak D. Computational modeling of mechanical anisotropy in the cornea and sclera. Journal of Cataract & Refractive Surgery 2005; 31(1): 136–145. [DOI] [PubMed] [Google Scholar]
- 74.Mao Z, Miki A, Mei S, et al. Automated 3D Lamina Cribrosa Segmentation in Optical Coherence Tomography Volumetric Scans.. In: ; 2019. [DOI] [PMC free article] [PubMed]
- 75.Zang P, Wang J, Hormel T, Liu L, Huang D, Jia Y. Automated Segmentation of Peripapillary Retinal Boundaries in OCT Combining Convolutional Neural Network and Graph Search.. In: ; 2019. [DOI] [PMC free article] [PubMed]
- 76.Huhnke FH, Russo JD, Wysmolek P, et al. The tissue within a retina organoid shows a yield stress, the amount of mechanical stress necessary to induce irreversible deformations, which regulates the retina’s mechanical integrity.. In: ; 2019.
- 77.Nguyen TD, Midgett D, Liu B, Quigley HA. Analysis for the effects of glaucoma and optic nerve damage on the pressure-induced strains in the human lamina cribrosa.. In: ; 2019.
- 78.O’Brien CJ, Murphy R, Irnaten M, Hopkins A. The role of lamina cribrosa tissue stiffness as a fundamental biomechanical driver of pathological glaucomatous cupping.. In: ; 2019. [DOI] [PubMed]
- 79.Harris A, Dinn RB, Kagemann L, Rechtman E. A Review of Methods for Human Retinal Oximetry. Ophthalmic Surgery, Lasers and Imaging Retina 2003; 34(2): 152–164. doi: 10.3928/1542-8877-20030301-16 [DOI] [PubMed] [Google Scholar]
- 80.Guidoboni G, Sacco R, Szopos M, et al. Neurodegenerative disorders of the eye and of the brain: a perspective on their fluid-dynamical connections and the potential of mechanism-driven modeling. Frontiers in Neuroscience 2020: 1173. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 81.Costa VP, Arcieri ES, Harris A. Blood pressure and glaucoma. British Journal of Ophthalmology 2009; 93(10): 1276–1282. [DOI] [PubMed] [Google Scholar]
- 82.Dorner GT, Polska E, Garhöfer G, Zawinka C, Frank B, Schmetterer L. Calculation of the diameter of the central retinal artery from noninvasive measurements in humans. Current eye research 2002; 25(6): 341–345. [DOI] [PubMed] [Google Scholar]
- 83.Harris A, Joos K, Kay M, et al. Acute IOP elevation with scleral suction: effects on retrobulbar haemodynamics.. British journal of ophthalmology 1996; 80(12): 1055–1059. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 84.Riva CE, Grunwald JE, Sinclair SH, Petrig B. Blood velocity and volumetric flow rate in human retinal vessels.. Investigative ophthalmology & visual science 1985; 26(8): 1124–1132. [PubMed] [Google Scholar]
- 85.Tham YC, Lim SH, Gupta P, Aung T, Wong TY, Cheng CY. Inter-relationship between ocular perfusion pressure, blood pressure, intraocular pressure profiles and primary open-angle glaucoma: the Singapore Epidemiology of Eye Diseases study. British Journal of Ophthalmology 2018; 102(10): 1402–1406. [DOI] [PubMed] [Google Scholar]
- 86.Sigal IA, Flanagan JG, Tertinegg I, Ethier CR. Finite element modeling of optic nerve head biomechanics. Investigative ophthalmology & visual science 2004; 45(12): 4378–4387. [DOI] [PubMed] [Google Scholar]
- 87.Yan D, Coloma F, Metheetrairut A, Trope G, Heathcote J, Ethier C. Deformation of the lamina cribrosa by elevated intraocular pressure.. British Journal of Ophthalmology 1994; 78(8): 643–648. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 88.Yan D, Flanagan J, Flanagan J, Farra T, Trope G, Ethier C. Study of regional deformation of the optic nerve head using scanning laser tomography. Current eye research 1998; 17(9): 903–916. [DOI] [PubMed] [Google Scholar]
- 89.Boyce BL, Grazier JM, Jones RE, Nguyen TD. Full-field deformation of bovine cornea under constrained inflation conditions. Biomaterials 2008; 29(28): 3896–3904. [DOI] [PubMed] [Google Scholar]
- 90.Detorakis ET, Pallikaris IG. Ocular rigidity: biomechanical role, in vivo measurements and clinical significance. Clinical & experimental ophthalmology 2013; 41(1): 73–81. [DOI] [PubMed] [Google Scholar]
- 91.Elsheikh A, Wang D, Brown M, Rama P, Campanelli M, Pye D. Assessment of corneal biomechanical properties and their variation with age. Current eye research 2007; 32(1): 11–19. [DOI] [PubMed] [Google Scholar]
- 92.Myers KM, Coudrillier B, Boyce BL, Nguyen TD. The inflation response of the posterior bovine sclera. Acta biomaterialia 2010; 6(11): 4327–4335. [DOI] [PubMed] [Google Scholar]
- 93.He Z, Nguyen CT, Armitage JA, Vingrys AJ, Bui BV. Blood pressure modifies retinal susceptibility to intraocular pressure elevation. PLoS One 2012; 7(2): e31104. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 94.Kerr J, Nelson P, O’Brien C. A comparison of ocular blood flow in untreated primary open-angle glaucoma and ocular hypertension. American journal of ophthalmology 1998; 126(1): 42–51. [DOI] [PubMed] [Google Scholar]
- 95.Ciancaglini M, Carpineto P, Costagliola C, Matropasqua L. Perfusion of the optic nerve head and visual field damage in glaucomatous patients. Graefe’s archive for clinical and experimental ophthalmology 2001; 239(8): 549–555. [DOI] [PubMed] [Google Scholar]
- 96.Findl O, Strenn K, Wolzt M, et al. Effects of changes in intraocular pressure on human ocular haemodynamics. Current eye research 1997; 16(10): 1024–1029. [DOI] [PubMed] [Google Scholar]
- 97.Morgan WH, Chauhan BC, Yu DY, Cringle SJ, Alder VA, House PH. Optic disc movement with variations in intraocular and cerebrospinal fluid pressure. Investigative ophthalmology & visual science 2002; 43(10): 3236–3242. [PubMed] [Google Scholar]
- 98.Sala L, Prud’homme C, Guidoboni G, Szopos M, Siesky BA, Harris A. Analysis of IOP and CSF alterations on ocular biomechanics and lamina cribrosa hemodynamics. Investigative Ophthalmology & Visual Science 2018; 59(9): 4475–4475. [Google Scholar]
- 99.Bhardwaj V, Rajeshbhai GP. Axial length, anterior chamber depth-a study in different age groups and refractive errors. Journal of clinical and diagnostic research: JCDR 2013; 7(10): 2211. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 100.Sala L, Prud’Homme C, Prada D, et al. Patient-specific virtual simulator of tissue perfusion in the lamina cribrosa.. In:. 58. The Association for Research in Vision and Ophthalmology; 2017: 727. [Google Scholar]
- 101.Chiaravalli G, Guidoboni G, Sacco R, Ciulla TA, Harris A. A theoretical study of vascular configurations of retinal capillary plexi based on OCTA data. Investigative Ophthalmology & Visual Science 2019; 60(9): 149–149. [Google Scholar]
- 102.Repetto R, Dvoriashyna M. Mathematical Models of Vitreous Humour Dynamics and Retinal Detachment: 303–325; Cham: Springer International Publishing. 2019 [Google Scholar]
- 103.Szopos M, Cassani S, Guidoboni G, et al. Mathematical modeling of aqueous humor flow and intraocular pressure under uncertainty: towards individualized glaucoma management. Journal for Modeling in Ophthalmology 2016; 2: 29–39. [Google Scholar]
- 104.Nunez R, Harris A, Ibrahim O, et al. Artificial Intelligence to Aid Glaucoma Diagnosis and Monitoring: State of the Art and New Directions. In:. 9. MDPI.; 2022: 810. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 105.Li Z, He Y, Keel S, Meng W, Chang RT, He M. Efficacy of a deep learning system for detecting glaucomatous optic neuropathy based on color fundus photographs. Ophthalmology 2018; 125(8): 1199–1206. [DOI] [PubMed] [Google Scholar]
- 106.Ran AR, Tham CC, Chan PP, et al. Deep learning in glaucoma with optical coherence tomography: a review. Eye 2021; 35(1): 188–201. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 107.Cockburn B, Dong B, Guzmán J, Restelli M, Sacco R. A Hybridizable Discontinuous Galerkin Method for Steady-State Convection-Diffusion-Reaction Problems. SIAM Journal on Scientific Computing 2009; 31(5): 3827–3846. [Google Scholar]
- 108.Qiu W, Shen J, Shi K. An HDG method for linear elasticity with strong symmetric stresses. Mathematics of Computation 2018; 87(309): 69–93. [Google Scholar]
