Optical Sensor System for 3D Jones Matrix Reconstruction of Optical Anisotropy Maps of Self-Assembled Polycrystalline Soft Matter Films

Waldemar Wójcik 1, Zhengbing Hu 2, Yuriy Ushenko 3, Andrzej Smolarz 1,*, Iryna Soltys 3, Oleksander Dubolazov 3,*, Oleksander Ushenko 3,4, Olexandra Litvinenko 5, Ivan Mikirin 3, Ivan Gordey 3, Oleksandr Pavlyukovich 5, Sergii Pavlov 6, Natalia Pavlyukovich 5, Saltanat Amirgaliyeva 7, Aliya Kalizhanova 8,9, Zhalau Aitkulov 8,10
Editor: Shyqyri Haxha
PMCID: PMC10933998  PMID: 38475128

Abstract

Our work uses a polarization matrix formalism to analyze and algorithmically represent optical anisotropy by open dehydration of blood plasma films. Analytical relations for Jones matrix reconstruction of optical birefringence maps of protein crystal networks of dehydrated biofluid films are found. A technique for 3D step-by-step measurement of the distributions of the elements of the Jones matrix or Jones matrix images (JMI) of the optically birefringent structure of blood plasma films (BPF) has been created. Correlation between JMI maps and corresponding birefringence images of dehydrated BPF and saliva films (SF) obtained from donors and prostate cancer patients was determined. Within the framework of statistical analysis of layer-by-layer optical birefringence maps, the parameters most sensitive to pathological changes in the structure of dehydrated films were found to be the central statistical moments of the 1st to 4th orders. We physically substantiated and experimentally determined the sensitivity of the method of 3D polarization scanning technique of BPF and SF preparations in the diagnosis of endometriosis of uterine tissue.

Keywords: Jones matrix, 3D reconstruction, blood plasma, optical anisotropy, diagnostics

1. Introduction

The relevance of diagnosis and treatment of prostate cancer is undeniable because of the high prevalence and hidden nature of the disease in the global male population [1,2,3]. The most important diagnostic task is the differentiation of prostate cancer stages, which determines the prognosis and treatment [4]. A variety of optical analysis techniques could be a promising avenue for addressing these pressing biomedical challenges [5,6,7,8,9,10]. The most sensitive to polarization manifestations of changes in the optical anisotropy of biological objects [11,12,13,14,15] are the multiparameter techniques of Mueller matrix [5,16,17], polarimetry [10,18,19,20,21,22,23], matrix decomposition [24,25] and coordinate mapping [26,27,28,29] using various analytical approximations [6,7,8,9], computer proceedings [30,31,32,33,34] and optically devises [35,36,37,38,39,40].

The most accurate (gold standard) and mandatory stage of diagnosis is histological and immunohistochemical examination of tumor biopsy, which allows us to make a final conclusion, determine the histological picture of the pathological condition with an accuracy that is close to the maximum (~100%) [41]. At the same time, these studies are not rapid, require the use of expensive reagents, are also largely subjective, and do not provide the possibility of quantitative analysis of the parameters of microscopic images of internal organ preparations.

Currently, instrumental high-precision (~95%) polarization interference methods for differential diagnosis of histological sections of prostate tumor biopsy have been developed, which are devoid of the above disadvantages of traditional histological examination [42].

At the same time, obtaining a biopsy is a traumatic and sometimes dangerous operation for patients’ health. Therefore, it is relevant to develop new rapid instrumental biophysical methods for differential diagnosis of prostate tumors using a minimally invasive procedure, an optical study of the polycrystalline structure of dehydrated films of biological fluids of human organs.

Polarimetric studies of the polarization manifestations of BF anisotropy make it possible to detect pathological changes in the quaternary and tertiary polycrystalline structure of basic proteins (albumin and globulin) in blood plasma and other biological fluids, which are inaccessible in the most common biochemical methods. In a series of works [43,44,45,46,47,48,49,50,51], the sensitivity of polarimetric methods to inflammatory, pathological and necrotic changes in the polycrystalline structure of films of blood plasma, urine, synovial fluid, and cerebrospinal fluid was demonstrated.

Despite such promising results in diagnosing the structure of biofluid films, there are still a number of unresolved problems. Among them are the following:

  1. There is no unified (unified) analytical description of polarization manifestations of optical properties of complex phase and amplitude anisotropic structure of networks of biological crystals in the volume of dehydrated BF films.

  2. Algorithms for polarization reconstruction of histograms of polycrystalline networks of biological crystal maps of various optical anisotropy mechanisms, birefringence and dichroism, have not been developed.

  3. Dehydrated BF films exhibit a complex spatially inhomogeneous volumetric structure of networks of biological crystals. On the other hand, polarization methods provide integrally averaged information over the whole volume of the biological layer in the form of 2D matrix element distributions. As a consequence, the sensitivity of existing methods of matrix polarimetry does not provide the capability to detect spatially localized changes of optical anisotropy of networks of biological crystals.

There is no unified medical-physical approach to the objective evaluation of diagnostic efficiency of matrix polarimetry methods.

Thus, a new and urgent issue of matrix polarimetry is the development of the Jones matrix model of analytical description of optical anisotropy of various types of dehydrated films of biological fluids followed by determination of algorithmic relationships between parameters of optical anisotropy of dehydrated BF films and values of partial matrix elements.

This polarimetric approach can be developed and generalized into a synthesis of polarization interference mapping and digital holographic reconstruction of object fields of complex amplitudes for layer-by-layer reconstruction of optical anisotropy maps of dehydrated BF films. Therefore, to improve the sensitivity and accuracy of polarimetric matrix diagnostics, it is urgent to create a new method for the layer-by-layer study of polycrystalline films of biological fluids by synthesizing polarization (Jones matrix) and interference methods [43,44,45,46,47,48,49,50].

In addition, the potential of the Jones matrix tomography technique can be expanded to other equally relevant areas, such as instrumental medical diagnostics COVID-19 [51,52,53]

Our work aims to create and validate a new experimental method of polarization interference multilayer Jones matrix scanning of the polycrystalline structure of blood plasma (BPF) and saliva (SF) for diagnosis and differentiation of prostate cancer stages.

2. Methods and Theory

According to traditional concepts [54,55], a polycrystalline film of any biological fluid can be represented as a sequence of partial layers with six different types of phase (optical birefringence–LB(0,90);(45,135), CB⊗,⊕) and amplitude (LD(0,90);(45,135), CD⊗,⊕) anisotropy. These LD0,90, LD45,135 and LB0,90, LB45,135–“linear dichroism–birefringence”; CD⊗;⊕ and CB⊗;⊕–“circular dichroism–birefringence” of biological layer optically anisotropic component for linearly (0° ÷ 90° and 45° ÷ 135°) and circularly right-(⊗) and left-(⊕) polarised others.

LB0;90=2πλn0n90h; (1)
LB45;135=2πλn45n135h; (2)
CB;=2πλnnh; (3)
LD0;90=2πλχ0χ90h; (4)
LD45;135=2πλχ45χ135h; (5)
CD;=2πλχχh; (6)

where n0,n90,n45,n135 and χ0,χ90,χ45,χ135 are refractive indices–absorption for orthogonal amplitude components 0°–90° and 45°–135°; λ—laser wavelength; h—geometrical layer thickness.

Given the insignificant absorption of dehydrated BPF and SF in our work, we limit ourselves to taking into account the effects of birefringence.

We describe the polarization manifestations of each optical anisotropy mechanism by the Jones partial matrix operators of the formula below [48]:

JLB0;90=exp0.5iLB0;9000exp0.5iLB0;90; (7)
JLB45;135=cos0.5LB45;135isin0.5LB45;135isin0.5LB45;135cos0.5LB45;135; (8)
JCB;=cosCB;sinCB;sinCB;cosCB;; (9)

An analytical form of the generalized Jones matrix of a polycrystalline medium with complex anisotropy was found in [48]

J=j11j12j21j22=cos0.5ViLVsin0.5VC  iLVsin0.5VC + iLVsin0.5Vcos0.5V+iLVsin0.5V (10)

Here V—generalized anisotropy vector

V=VL0;90,L45;135;C;, (11)

where

L0;90=LB0;90;L45;135=LB45;135;C;=CB;.. (12)

From (11) and (12) we obtain an explicit form of the vector modulus V

V=L0;90+L45;135+C;0.5=LB20;90+(LB245;135)+CB2;0.5, (13)

On the basis of (7)–(13), we obtain theoretical interrelations between the parameters of linear and circular birefringence dichroism and elements of the Jones matrix J of an optically anisotropic layer

V=2arccos0.5Rej11+Rej22; (14)
LB0;90=V2sin0.5VImj22Imj11; (15)
LB45,135=V2sin0.5VImj12+Imj21; (16)
CB;=V2sin0.5VImj12Imj21 (17)

The algorithm for calculating the elements of the Jones matrix J (Expression (1)) includes the irradiation of a polycrystalline film sample by linearly polarised beams with azimuths 0° (Jones vector 10) and 90° (Jones vector 01)

U0=Ux0Uyo=j11j12j21j2210j11j21Ux0=1000j11j12j11;Uy0=0001j11j12j21; (18)
U90=Ux90Uy90=j11j12j21j2201j12j22Ux90=1000j12j22j21;Uy90=0001j12j22j22. (19)

As a result, we obtain the following expressions for the Jones matrix tomography of the polycrystalline structure of a biological fluid film

V=2arccos0.5Ux0expiφx0+Uy90expiφy90; (20)
LB0;90=V2sin0.5VUy90sinφy90Ux0sinφx0; (21)
LB45,135=V2sin0.5VUy0sinφy0Ux90sinφx90; (22)
CB;=V2sin0.5VUy0sinφy0Ux90sinφx90; (23)

In further experimental studies, we will use the generally accepted parameters for the different types of birefringence

LB=LB0;902+LB45;1352; (24)
CBCB;. (25)

3. Optical Scheme of 3D Jones Matrix Scanning of BPF and SF

Figure 1 shows a diagram of the polarization interferometry of Jones layer-by-layer distributions of dehydrated films JMI [46,47,49].

Figure 1.

Figure 1

Optical scheme of optical sensor system for Jones matrix tomography of polycrystalline films of biological fluids. 1—HeNe laser (Ø = 2 × 103 μm, λ = 0.6328 μm); 2—collimator; 3—light splitter (50%); 4—turning mirror; 5, 7, 10, 12, 13—linear polarizers; 6, 11—quarter wave plates; 8—sample of dehydrated film; 9—polarizing microobjective; 14—digital camera; 15—PC.

4. The Method of 3D Jones Matrix Scanning of BPF and SF

1. Two states of linear polarisation are sequentially formed in the “irradiating” (Ir) and “reference” (Re) parallel laser beams–Ir(0°)Re(0°)p i Ir(90°)Re(90°)r.

2. For each of the polarization states (p and r), two partial interference patterns are recorded through the polarizer-analyzer 14 with the orientation of the transmission plane at angles Ω=0°;Ω=90°.

3. Analytical processing of microscopic interference images of dehydrated film samples was carried out using the digital Fourier transform Fυ,ν [49]:

F0;90υ,ν=1M×Nm=0M1n=0N1Ix,yΩ=0°;90°expi2πm×υM+n×νN. (26)

where

Ix0Ω=0°m,n=Ux0Ω=0°m,nUx0*Ω=0°m,n;Ix90Ω=90°m,n=Ux90Ω=90°m,nUx90*Ω=90°m,nIy0Ω=0°m,n=Uy0Ω=0°m,nUy0*Ω=0°m,nIy90Ω=90°m,n=Uy90Ω=90°m,nUy90*Ω=90°m,n

Ux,y0,90, orthogonal components of complex amplitude for different orientations, Ω=0°;Ω=90°; * denotes the complex conjugation operation; υ,ν are the spatial frequencies and m=1120,n=960 are the number of pixels of the CCD camera

4. The results of the digital Fourier transform (Relations (25), (26)) are used to obtain distributions of complex amplitudes according to the following algorithms:

Ω00Ux0Ω=0°;Ω900Ux90Ω=90°expiφx90φx0; (27)
Ω00Uy0Ω=0°;Ω900Uy90Ω=90°expiφy90φy0 (28)

5. By means of stepwise (Δθ) phase (θk) scanning of the reconstructed field of complex amplitudes (Relations (27), (28)) using Algorithms (20)–(25), we obtain coordinate distributions of the optical birefringence parameters JTθk,m×n.

5. Statistical Analysis of Maps of Linear and Circular Birefringence of Polycrystalline Films of Biological Fluids

The resulting set of optical anisotropy maps fLBθk,m,n;CBθ,m,n was analyzed in a statistical approach using the following algorithms to calculate mean (Z1), variance (Z2), skewness (Z3) and kurtosis (Z4) [43,44,45,46,47,48,49,50,51]

Z1=1Kj=1Kfj;Z2=1Kj=1Kf2j;Z3=1Z231Kj=1Kf3j;Z4=1Z241Kj=1Kf4j, (29)

where K=M×N—CCD pixels quantity.

6. Diagnostic Method

The search for the most sensitive phase plane was carried out as follows.

1. At the first stage:

  • Discrete phase scanning was carried out in “maximum” increments Δθkmax=0.25 rad.

  • Using Relations (20)–(25), birefringence maps were calculated fLBθk,m,n;CBθ,m,n.

  • Central statistical moments Zi=1;2;3;4 were calculated for the optical anisotropy distributions fLBθk,m,n;CBθ,m,n.

  • The differences between the obtained values of the statistical parameters were assessed ΔZik=Ziθj+1maxZiθjmax.

  • The phase interval Δθ*=θj+1max÷θjmax was determined, within which the monotonic increase in the value ends ΔZi=(Ziθj+1maxZiθjmax)0.

  • The macrointerval phase found Δθ* was analyzed again in finer increments Δθqmin=0.05 radΔZi=Ziθj+1minZiθjmin.

  • The new (most sensitive) phase section θ* was determined, in which ΔZiθ*=max.

2. In this plane θ*, the mean ΔZ¯i=1;2;3;4* and standard deviations σΔZi* are determined

Therefore, prostate tumor diagnosis, for each of the statistical moments Zi=1;2;3;4 the sensitivity

(Se12f=a12a12+b12100%; Se34f=a34a34+b34100), (30)

specificity

(Sp12f=c12c12+d12100%; Sp34f=c34c34+d34100%) (31)

and balanced accuracy

(Ac12f=0.5Se12+Sp12; Ac34f=0.5Se34+Sp34) (32)

were calculated [56,57,58,59].

Here, a12a34 and b12b34 are the number of correct and incorrect diagnoses within investigation group 2 (group 4); and c12c34 and d12d34 are the same within control group 1 (group 3).

7. Biological Samples

Blood and saliva samples were taken for the purpose of determination of the prostate tumor [60,61,62,63].

Experimental blood plasma samples were obtained by centrifugation. Liquid drops with a volume of 10 μL were applied onto optically homogeneous glass heated to the temperature of the human body (36.6 °C). The process of complete drying (dehydration) lasted 45–50 min.

Experimental saliva samples were obtained by taking 2–3 mL of liquid into a test tube and settling it until the mucin proteins precipitated. Then, by centrifugation, the liquid and sedimentary components were separated. A drop of liquid with a volume of 10 μL was applied to optically homogeneous glass heated to the temperature of the human body (36.6 °C). The process of complete drying (dehydration) lasted 40–45 min.

The main biochemical components of blood plasma are water (90%), proteins (7%), organic nonprotein compounds (2%), salts (1%). Protein composition—60% albumin, 40% globulin.

It is known [62] that in the process of blood plasma dehydration, a dry (polycrystalline) drop is formed, which contains three zones:

  • “outer”—an annular ridge, which almost entirely consists of linearly birefringent needlelike albumin crystals (h~12 μm15 μm);

  • “transitional”—circularly birefringent structure of globulin crystals with a small content of albumin crystals and optically isotropic crystals of NaCl salt (h~10 μm12 μm);

  • “Central”—solid crystals of NaCl salt (h~7 μm10 μm).

The composition of saliva and blood plasma is correlated with each other. Saliva contains the same protein fractions as blood plasma—albumin and globulins. At the same time, among them, there are significantly fewer albumins and four times more globulins.

When a saliva drop is dehydrated, the crystallization results differ significantly from the polycrystalline structure of a blood plasma drop. This is due to the lower concentration of albumin and globulin proteins in saliva. Therefore, the marginal protein roll is not formed.

A dry drop of saliva has the form of a film quasi-uniform in thickness (h~10 μm÷15 μm), where optically isotropic dendritic networks of cubic crystals of NaCl salt are localized.

Such a film contains, in the form of domains, large (linearly birefringent needlelike albumin crystals) and small (circularly birefringent globulin crystals) optically anisotropic aggregates with a range of sizes h=10 μm÷500 μm.

Four representative groups of blood plasma and saliva polycrystalline films were formed:

  • Group 1 consisted of n=36 samples of BPF from healthy donors;

  • Group 2 consisted of n=36 samples of BPF films of patients with moderately differentiated adenocarcinoma (3 + 4; 4 + 3 on Gleason’s Pattern scale-ISUP grade 2–3);

  • Group 3 consisted of n=36 SF samples from healthy donors.

  • Group 4 consisted of n=36 SF samples from patients with moderately differentiated adenocarcinoma (3 + 4; 4 + 3 on Gleason’s Pattern scale-ISUP grade 2–3).

8. Results

At the first stage, layer-by-layer maps fLBθk,m,n;CBθ,m,n of BPF and SF of healthy donors were studied. The results of 3D Jones matrix layer-by-layer tomography for phase planes θk=0.1 rad;0.25 rad;0.5 rad are presented in the framework of statistical analysis of changes in coordinate distributions of the magnitude of optical birefringence parameters of supramolecular networks of biological crystals.

Such processes are quantitatively characterized by a set of mean values Z¯i and standard deviations ±2σ (within group 1 and group 3) of the values of statistical moments Zi (Relation (29)) characterizing the maps of optical anisotropy fLBθk,m,n;CBθ,m,n of polycrystalline films of blood plasma and saliva (Table 1).

Table 1.

Statistical parameters of optical anisotropy maps of BPF and SF of healthy donors.

f LBθk,m,n CBθk,m,n
Zi Blood Plasma Group 1
n = 36
Saliva Group 3
n = 36
Blood Plasma Group 1
n = 36
Saliva Group 3
n = 36
θk θ=0.1 rad
Z1×103 0.15 ± 0.012 0.021 ± 0.0011 0.09 ± 0.006 0.08 ± 0.003
Z2×103 0.12 ± 0.008 0.015 ± 0.0007 0.07 ± 0.008 0.06 ± 0.002
Z3 1.54 ± 0.068 2.29 ± 0.11 2.12 ± 0.105 1.96 ± 0.088
Z4 2.18 ± 0.098 3.11 ± 0.14 2.81 ± 0.13 2.73 ± 0.12
θk θ=0.25 rad
Z1×103 0.24 ± 0.011 0.031 ± 0.0014 0.14 ± 0.007 0.12 ± 0.006
Z2×103 0.16 ± 0.008 0.017 ± 0.0007 0.11 ± 0.008 0.09 ± 0.004
Z3 1.12 ± 0.068 1.62 ± 0.084 1.31 ± 0.061 1.22 ± 0.056
Z4 1.51 ± 0.068 2.42 ± 0.12 2.13 ± 0.11 2.04 ± 0.105
θk θ=0.5 rad
Z1×103 0.33 ± 0.014 0.039 ± 0.0015 0.16 ± 0.007 0.14 ± 0.006
Z2×103 0.21 ± 0.009 0.015 ± 0.0007 0.12 ± 0.005 0.09 ± 0.004
Z3 0.62 ± 0.029 0.91 ± 0.044 0.74 ± 0.031 0.69 ± 0.028
Z4 1.08 ± 0.045 1.53 ± 0.072 1.41 ± 0.064 1.35 ± 0.061

The data obtained revealed the individual means of all parameters Zi, characterizing the statistical structure of BPF and SF maps fLBθk,m,n;CBθ,m,n, in all phase planes, θk=0.1 rad;0.25 rad;0.5 rad.

The largest phase (θk) differences were found for the statistical moments of the 3rd and 4th orders, which characterize the skewness and kurtosis of the distributions of the optical anisotropy parameters fLBθk,m,n;CBθ,m,n of polycrystalline films of biological fluids:

  • BPF-ΔZ3LB=2.48;ΔZ4LB=2.02 and ΔZ3CB=2.86;ΔZ4CB=1.99;

  • SF-ΔZ3LB=2.52;ΔZ4LB=2.03 and ΔZ3CB=2.84;ΔZ4CB=2.02

9. Diagnosis of Prostate Cancer

The results of 3D Jones scanning of the BPF and SF from the control (group 1 and group 3) and experimental (group 2 and group 4) for the experimentally optimal phase planes (θblood*δ=0.35 rad;θsaliva*δ=0.35 rad and θblood*ω=0.25 rad;θsaliva*ω=0.25 rad;) are shown in a series of fragments in Figure 2 and Figure 3.

Figure 2.

Figure 2

Topographic maps of linear θblood*LB=0.35rad (Fragments (1), (2)) and circular θblood*CB=0.25rad (Fragments (3), (4)) birefringence of healthy donors BPF (Fragments (1), (3)) and sick patients (Fragments (2), (4)).

Figure 3.

Figure 3

Topographic maps of linear θblood*LB=0.35rad (Fragments (1), (2)) and circular θblood*CB=0.25rad (Fragments (3), (4)) birefringence of SF of healthy donors (Fragments (1), (3)) and sick patients (Fragments (2), (4)).

On a series of fragments of Figure 2 and Figure 3 represent, reconstructed by Jones matrix tomography, coordinate distributions (optical anisotropy maps) of linear LBθ*,m,n (Fragments (1),(2)) and circular CBθ*,m,n (Fragments (3),(4)) birefringence of supramolecular networks of dehydrated plasma films (Figure 2) and saliva (Figure 3) of healthy donors (Fragments (1), (3)) and prostate cancer patients (Fragments (2), (4)).

Comparison of the obtained data revealed a correlation between the model analysis (Ratios (1)–(25)) and the experimental results (Figure 2 and Figure 3). Namely:

  • The presence of mechanisms of linear LBθ*,m,n and circular CBθ*,m,n birefringence of supramolecular networks of dehydrated films of biological fluids with different morphological architectonics (Figure 2 and Figure 3).

  • Individual topographic structure of maps of various birefringence mechanisms LB and CB, which are formed dendritic (Fragments (1), (2)) and spherulitic (Fragments (1), (2)) components of optically anisotropic supramolecular networks of biological crystals of dehydrated blood plasma films (Figure 2) and saliva (Figure 3).

  • Insignificant differences (the magnitude of the average and the amplitude of fluctuations) between topographic maps of linear birefringence of LBθ*,m,n dendritic components of optically anisotropic architectonics of dehydrated plasma films (Figure 2) and saliva (Figure 3) of healthy donors (Fragments (1)) and prostate cancer patients (Fragments (2)).

  • A significant increase in the circular birefringence of CBθ*,m,n spherulite components of the optically anisotropic architectonics of dehydrated plasma films (Figure 2) and saliva (Figure 3) of healthy donors (Fragments (3)) and prostate cancer patients (Fragments (4)).

Quantitative and objective scenarios of changes in various types of birefringence LBθ*,m,n and CBθ*,m,n. The optically anisotropic architectonics of dehydrated films of biological fluids of both types are illustrated by statistical analysis data (ratios (29)), which are presented in Table 2.

Table 2.

Statistical parameters of optical anisotropy maps in sections θ*LB=0.35rad and θ*CB=0.25rad fields of complex amplitudes of BPF and SF.

θk θ*LB=0.35rad θ*CB=0.25rad
Zi Blood Plasma Group 1
n = 36
Blood Plasma Group 2
n = 36
Blood Plasma Group 1
n = 36
Blood Plasma Group 2
n = 36
Z1×103 0.24 ± 0.011 0.19 ± 0.009 0.14 ± 0.007 0.21 ± 0.011
Z2×103 0.16 ± 0.008 0.13 ± 0.007 0.11 ± 0.008 0.16 ± 0.009
Z3 1.12 ± 0.068 1.45 ± 0.076 1.31 ± 0.061 0.81 ± 0.036
Z4 1.51 ± 0.068 2.05 ± 0.108 2.13 ± 0.11 1.31 ± 0.09
Zi Saliva
Group 3
n = 36
Saliva
Group 4
n = 36
Saliva
Group 3
n = 36
Saliva
Group 4
n = 36
Z1×103 0.031 ± 0.0014 0.027 ± 0.0011 0.12 ± 0.006 0.17 ± 0.008
Z2×103 0.017 ± 0.0007 0.015 ± 0.0006 0.09 ± 0.004 0.14 ± 0.006
Z3 1.62 ± 0.084 1.88 ± 0.094 1.22 ± 0.056 0.72 ± 0.035
Z4 2.42 ± 0.12 2.84 ± 0.14 2.04 ± 0.105 1.24 ± 0.075

The maximum intergroup differences were established:

  • BPF-ΔZ3CB=1.62;ΔZ4CB=1.63;

  • SF-ΔZ3CB=1.69;ΔZ4CB=1.65.

For these statistical parameters, Table 3 shows the values of the sensitivity Se, specificity Sp and balanced accuracy Ac of the method of layer-by-layer Jones matrix mapping with reproduction of maps of linear and circular birefringence of polycrystalline films of blood plasma and saliva.

Table 3.

Characteristics of the diagnostic power of the 3D matrix scanning method of BPF and SF.

w LBθ*=0.35rad CBθ*=0.25rad
Groups Group 1–Group 2 Group 3–Group 4 Group 1–Group 2 Group 3–Group 4
Se (%) 88.9 75 94.4 97.2
Sp (%) 86.1 77.8 91.7 94.4
Ac (%) 87.5 76.4 93.05 95.8

The results shown in Table 3 indicate a different efficiency in diagnosing prostate cancer by Jones matrix layered reproduction of maps of linear LBθ*,m,n and circular CBθ*,m,n birefringence of BPF and SF.

It was found that the layer-by-layer mapping of the linear birefringence distributions LBθ*,m,n of the dendritic component of the optically anisotropic architectonics of dehydrated plasma films is quite sensitive and accurate (87.5%) to the pathological change in the structure of supramolecular networks of needlelike albumin crystals.

The accuracy of a similar diagnosis for the dendritic component of the supramolecular network of the dehydrated saliva film appears to be significantly lower (76.4%) due to a lower level of linear birefringence of needle-shaped albumin crystals and a high concentration of optically isotropic cubic NaCl crystals.

The most optimal and practically independent of the type of biological fluid was the statistical analysis of the coordinate distributions of the circular birefringence value CBθ*,m,n associated with the concentration of globulins. In this situation, an excellent level of balanced accuracy was achieved: AcZ3;4=93.05%÷95.8%.

10. Conclusions

For the first time, the Jones matrix analytical model for the optical anisotropy description of different types of dehydrated films of biological fluids, such as blood plasma and saliva, is proposed. New algorithmic relationships between phase anisotropy parameters (birefringence and optical activity) of dehydrated films and values of partial elements of the Jones matrix were found. Based on the synthesis of polarization interference mapping and digital holographic reconstruction of object fields of complex amplitudes, a new technique of phase Jones matrix scanning with the subsequent layer-by-layer reconstruction of optically mapped optically anisotropic structure of dehydrated biological liquid films was developed and tested experimentally for the first time. An original algorithm for determining the cross section in the volume of dehydrated films of biological fluids is proposed, which is most effective for differential diagnosis of pathological changes in optical birefringence. New objective criteria (markers) for high accuracy (93.05% to 95.8%) diagnosis and differentiation (91.7% to 94.4%) of prostate cancer stages have been defined in the statistical Jones matrix analysis of the reconstructed optical anisotropy maps of dehydrated blood plasma and saliva samples.

The present study is one of the first steps in the fundamental development and experimental testing of the diagnostic potential of the Jones express technique matrix tomography of polycrystalline architectonics of dehydrated human fluid films.

The next steps in the development of this method will be experimental studies planned on the scale of clinical institutions of the countries represented by the members of the author’s team for the purpose of expert evaluation and determination of the validity of Jones matrix tomography of pathological conditions of human organs.

Author Contributions

Conceptualization, W.W., O.U. and O.D.; methodology, O.D., Z.H. and I.S.; software, Y.U., I.M. and I.G.; validation, A.S., O.P. and S.P.; formal analysis, O.L.; investigation, N.P., S.A. and A.K.; resources, O.U.; data curation, I.S. and Z.A.; writing—original draft preparation, W.W., Z.H., O.D. and I.S.; writing—review and editing, A.S., S.P. and A.K.; visualization, O.L. and O.P.; supervision, W.W., Z.H. and O.U.; project administration, W.W., A.S. and S.P.; funding acquisition, W.W. All authors have read and agreed to the published version of the manuscript.

Institutional Review Board Statement

This study was conducted in accordance with the principles of the Declaration of Helsinki, and in compliance with the International Conference on Harmonisation-Good Clinical Practice and local regulatory requirements. Ethical approval was obtained from the Ethics Committee of the Bureau of Forensic Medicine of the Chernivtsi National University and the Bukovinian State Medical University (Protocol of meeting No. 8 dated May 18, 2023, Chernivtsi, Ukraine), and written informed consent was obtained from all subjects prior to study initiation.

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

The data presented in this study are available on request from the corresponding author. As the research involves human tissue, the availability of data is subject to the decision of the relevant ethics committee.

Conflicts of Interest

The authors declare no conflicts of interest.

Funding Statement

This work is supported by grant from the Ministry of Science and higher Education of the Republic of Kazakhstan within the framework of the Project № AP09259547 «Development of a system of distributed fiber-optic sensors based on fiber Bragg gratings for monitoring the state of building structures», Institute Information and Computational Technologies CS MSHE RK.

Footnotes

Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

References

  • 1.Mohler J., Antonarakis E.S., Armstrong A.J., D’Amico A.V., Davis B.J., Dorff T., Eastham J., Enke C., Farrington T., Higano C. Prostate Cancer. J. Natl. Compr. Cancer Netw. 2010;8:162–200. doi: 10.6004/jnccn.2010.0012. [DOI] [PubMed] [Google Scholar]
  • 2.Grönberg H. Prostate cancer epidemiology. Lancet. 2003;361:859–864. doi: 10.1016/S0140-6736(03)12713-4. [DOI] [PubMed] [Google Scholar]
  • 3.Ilic D., Neuberger M.M., Djulbegovic M., Dahm P. Screening for prostate cancer. Cochrane Database Syst. Rev. 2013;1 doi: 10.1002/14651858.CD004720.pub3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Albertsen P.C., Hanley J.A., Fine J. 20-Year outcomes following conservative management of clinically localized prostate cancer. J. Am. Med. Assoc. 2005;293:2095–2101. doi: 10.1001/jama.293.17.2095. [DOI] [PubMed] [Google Scholar]
  • 5.Tuchin V.V. Tissue Optics and Photonics: Light-Tissue Interaction. J. Biomed. Photonics Eng. 2015;1:98–134. doi: 10.18287/JBPE-2015-1-2-98. [DOI] [Google Scholar]
  • 6.Tuchin V.V. Biomedical Photonics Handbook. CRC Press; Boca Raton, FL, USA: 2014. [Google Scholar]
  • 7.Tuchin V.V. Handbook of Biomedical Optics. CRC Press; Boca Raton, FL, USA: 2011. [Google Scholar]
  • 8.Tuchin V.V. Tissue Optics: Light Scattering Methods and Instruments for Medical Diagnosis. 3rd ed. Society of Photo-Optical Instrumentation Engineers (SPIE); Bellingham, WA, USA: 2015. [Google Scholar]
  • 9.Wang L.V., Wu H.-I. Biomedical Optics: Principles and Imaging. John Wiley & Sons, Inc.; Hoboken, NJ, USA: 2009. [Google Scholar]
  • 10.Ushenko A.G., Pishak V.P. Laser Polarimetry of Biological Tissues: Principles and Applications. In: Tuchin V.V., Valeri V., editors. Handbook of Coherent Domain Optical Methods. Springer; New York, NY, USA: 2004. pp. 93–138. [Google Scholar]
  • 11.Ghosh N. Tissue polarimetry: Concepts, challenges, applications, and outlook. J. Biomed. Opt. 2011;16:110801. doi: 10.1117/1.3652896. [DOI] [PubMed] [Google Scholar]
  • 12.Jacques S.L. Polarized light imaging of biological tissues. In: Boas D., Pitris C., Ramanujam N., editors. Handbook of Biomedical Optics. CRC Press; Boca Raton, FL, USA: 2011. pp. 649–669. [Google Scholar]
  • 13.Ghosh N., Wood M., Vitkin A. Polarized Light Assessment of Complex Turbid Media Such as Biological Tissues Using Mueller Matrix Decomposition. In: Tuchin V.V., editor. Handbook of Photonics for Biomedical Science. CRC Press; Boca Raton, FL, USA: 2010. pp. 253–282. [Google Scholar]
  • 14.Layden D., Ghosh N., Vitkin I.A. Quantitative polarimetry for tissue characterization and diagnosis. In: Wang R.K., Tuchin V.V., editors. Advanced Biophotonics: Tissue Optical Sectioning. CRC Press; Boca Raton, FL, USA: 2013. pp. 73–108. [Google Scholar]
  • 15.Vitkin A., Ghosh N., de Martino A. Tissue Polarimetry. In: Andrews D.L., editor. Photonics: Scientific Foundations, Technology and Applications. John Wiley & Sons, Ltd.; Hoboken, NJ, USA: 2015. pp. 239–321. [Google Scholar]
  • 16.Mishchenko M.I., Travis L.D., Lacis A.A. Scattering, Absorption, and Emission of Light by Small Particles. Cambridge University Press; Cambridge, UK: 2002. [Google Scholar]
  • 17.Tuchin V.V. Tissue Optics and Photonics: Biological Tissue Structures. J. Biomed. Photonics Eng. 2015;1:3–21. doi: 10.18287/JBPE-2015-1-1-3. [DOI] [Google Scholar]
  • 18.Swami M.K., Patel H.S., Gupta P.K. Conversion of 3 × 3 Mueller matrix to 4 × 4 Mueller matrix for non-depolarizing samples. Opt. Commun. 2013;286:18–22. doi: 10.1016/j.optcom.2012.08.094. [DOI] [Google Scholar]
  • 19.Izotova V.F., Maksimova I.L., Nefedov I.S., Romanov S.V. Investigation of Mueller matrices of anisotropic nonhomogeneous layers in application to an optical model of the cornea. Appl. Opt. 1997;36:164. doi: 10.1364/AO.36.000164. [DOI] [PubMed] [Google Scholar]
  • 20.Manhas S., Swami M.K., Buddhiwant P., Ghosh N., Gupta P.K., Singh K. Mueller matrix approach for determination of optical rotation in choral turbid media in backscattering geometry. Opt. Express. 2006;14:190. doi: 10.1364/OPEX.14.000190. [DOI] [PubMed] [Google Scholar]
  • 21.Deng Y., Zeng S., Lu Q., Zhu D., Luo Q. Characterization of backscattering Mueller matrix patterns of highly scattering media with triple scattering assumption. Opt. Express. 2007;15:9672. doi: 10.1364/OE.15.009672. [DOI] [PubMed] [Google Scholar]
  • 22.Angelsky O.V., Ushenko A., Ushenko Y.A., Pishak V.P., Peresunko A.P. Statistical, Correlation, and Topological Approaches in Diagnostics of the Structure and Physiological State of Birefringent Biological Tissues. In: Tuchin V.V., editor. Handbook of Photonics for Biomedical Science. CRC Press; Boca Raton, FL, USA: 2010. pp. 283–322. [Google Scholar]
  • 23.Ushenko Y.A., Boychuk T.M., Bachynsky V.T., Mincer O.P. Diagnostics of Structure and Physiological State of Birefringent Biological Tissues: Statistical, Correlation and Topological Approaches. In: Tuchin V.V., editor. Handbook of Coherent-Domain Optical Methods. Volume 1–2. Springer; New York, NY, USA: 2013. pp. 107–148. [Google Scholar]
  • 24.Pierangelo A., Manhas S., Benali A., Fallet C., Totobenazara J.L., Antonelli M.R., Novikova T., Gayet B., De Martino A., Validire P. Multispectral Mueller polarimetric imaging detecting residual cancer and cancer regression after neoadjuvant treatment for colorectal carcinomas. J. Biomed. Opt. 2013;18:046014. doi: 10.1117/1.JBO.18.4.046014. [DOI] [PubMed] [Google Scholar]
  • 25.Du E., He H., Zeng N., Sun M., Guo Y., Wu J., Liu S., Ma H. Mueller matrix polarimetry for differentiating characteristic features of cancerous tissues. J. Biomed. Opt. 2014;19:076013. doi: 10.1117/1.JBO.19.7.076013. [DOI] [PubMed] [Google Scholar]
  • 26.Lu S.-Y., Chipman R.A. Interpretation of Mueller matrices based on polar decomposition. J. Opt. Soc. Am. 1996;13:1106. doi: 10.1364/JOSAA.13.001106. [DOI] [Google Scholar]
  • 27.Guo Y., Zeng N., He H., Yun T., Du E., Liao R., He Y., Ma H. A study on forward scattering Mueller matrix decomposition in anisotropic medium. Opt. Express. 2013;21:18361. doi: 10.1364/OE.21.018361. [DOI] [PubMed] [Google Scholar]
  • 28.Buscemi I.C., Guyot S. Near real-time polarimetric imaging system. J. Biomed. Opt. 2013;18:1. doi: 10.1117/1.JBO.18.11.116002. [DOI] [PubMed] [Google Scholar]
  • 29.DeBoo B., Sasian J., Chipman R. Degree of polarization surfaces and maps for analysis of depolarization. Opt. Express. 2004;12:4941. doi: 10.1364/OPEX.12.004941. [DOI] [PubMed] [Google Scholar]
  • 30.Hu Z., Ivashchenko M., Lyushenko L., Klyushnyk D. Artificial Neural Network Training Criterion Formulation Using Error Continuous Domain. Int. J. Mod. Educ. Comput. Sci. IJMECS. 2021;13:13–22. doi: 10.5815/ijmecs.2021.03.02. [DOI] [Google Scholar]
  • 31.Hu Z., Tereikovskyi I., Chernyshev D., Tereikovska L., Tereikovskyi O., Wang D. Procedure for Processing Biometric Parameters Based on Wavelet Transformations. Int. J. Mod. Educ. Comput. Sci. IJMECS. 2021;13:11–22. doi: 10.5815/ijmecs.2021.02.02. [DOI] [Google Scholar]
  • 32.Hu Z., Odarchenko R., Gnatyuk S., Zaliskyi M., Chaplits A., Bondar S., Borovik V. Statistical Techniques for Detecting Cyberattacks on Computer Networks Based on an Analysis of Abnormal Traffic Behavior. Int. J. Comput. Netw. Inf. Secur. IJCNIS. 2020;12:1–13. doi: 10.5815/ijcnis.2020.06.01. [DOI] [Google Scholar]
  • 33.Hu Z., Gnatyuk S., Okhrimenko T., Tynymbayev S., Iavich M. High-Speed and Secure PRNG for Cryptographic Applications. Int. J. Comput. Netw. Inf. Secur. IJCNIS. 2020;12:1–10. doi: 10.5815/ijcnis.2020.03.01. [DOI] [Google Scholar]
  • 34.Hu Z., Dychka I., Onai M., Zhykin Y. Blind Payment Protocol for Payment Channel Networks. Int. J. Comput. Netw. Inf. Secur. IJCNIS. 2019;11:22–28. doi: 10.5815/ijcnis.2019.06.03. [DOI] [Google Scholar]
  • 35.Kolobrodov V.G., Nguyen Q.A., Tymchik G.S. The problems of designing coherent spectrum analyzers; Proceedings of the SPIE, of the 11th International Conference on Correlation Optics; Chernivtsi, Ukraine. 18–21 September 2013; [Google Scholar]
  • 36.Ostafiev V.A., Sakhno S.P., Ostafiev S.V., Tymchik G.S. Laser diffraction method of surface roughness measurement. J. Mater. Process. Technol. 1997;63:871–874. doi: 10.1016/S0924-0136(96)02741-0. [DOI] [Google Scholar]
  • 37.Chyzh I., Kolobrodov V., Molodyk A., Mykytenko V., Tymchik G., Romaniuk R., Kisała P., Kalizhanova A., Yeraliyeva B. Energy resolution of dual-channel opto-electronic surveillance system; Proceedings of the Photonics Applications in Astronomy, Communications, Industry, and High Energy Physics Experiments; Wilga, Poland. 31 August–2 September 2020; [Google Scholar]
  • 38.Kolobrodov V.H., Mykytenko V.I., Tymchik G.S. Polarization model of thermal contrast observation objects. Thermotlectricity. 2020;1:36–49. [Google Scholar]
  • 39.Kolobrodov V.G., Tymchik G.S., Kolobrodov M.S., Vasyura A.S., Komada P., Azehsova Z. The output signal of a digital optoelectronic processor; Proceedings of the SPIE Photonics Applications in Astronomy, Communications, Industry, and High-Energy Physics Experiments; Wilga, Poland. 3–10 June 2018; pp. 256–263. [Google Scholar]
  • 40.Tymchik G.S., Skytsyuk V.I., Klotchko T.R., Bezsmertna H., Wójcik W., Luganskaya S., Zhassulan O., Iskakova A. Diagnosis abnormalities of limb movement in disorders of the nervous system; Proceedings of the SPIE Photonics Applications in Astronomy, Communications, Industry, and High-Energy Physics Experiments; Wilga, Poland. 9 May–4 June 2017; pp. 1139–1149. [Google Scholar]
  • 41.Fenton J.J., Weyrich M.S., Durbin S., Liu Y., Bang H., Melnikow J. Prostate-Specific Antigen-Based Screening for Prostate Cancer: A Systematic Evidence Review for the U.S. Preventive Services Task Force. Agency for Healthcare Research and Quality (US); Rockville, MD, USA: 2018. Report No.: 17-05229-EF-1. [PubMed] [Google Scholar]
  • 42.Sdobnov A., Ushenko V.A., Trifonyuk L., Dubolazov O.V., Ushenko Y.A., Ushenko A.G., Soltys I.V., Gantyuk V.K., Bykov A., Meglinski I. Polarization-based optical interference approach for differential diagnosis of benign and malignant tumours. Opt. Lasers Eng. 2023;171:107806. doi: 10.1016/j.optlaseng.2023.107806. [DOI] [Google Scholar]
  • 43.Huang T., Meng R., Qi J., Liu Y., Wang X., Chen Y., Liao R., Ma H. Fast Mueller matrix microscope based on dual DoFP polarimeters. Opt. Lett. 2021;46:1676–1679. doi: 10.1364/OL.421394. [DOI] [PubMed] [Google Scholar]
  • 44.Zhao Q., Huang T., Hu Z., Bu T., Liu S., Liao R., Ma H. Geometric Optimization Method for Polarization State Generator of Mueller Matrix Microscope. Opt. Lett. 2021;46:5631–5634. doi: 10.1364/OL.441492. [DOI] [PubMed] [Google Scholar]
  • 45.Hotra O., Kovtun S., Dekusha O. Analysis of the characteristics of bimetallic and semiconductor heat flux sensors for in-situ measurements of envelope element thermal resistance. Meas. J. Int. Meas. Confed. 2021;182:109713. doi: 10.1016/j.measurement.2021.109713. [DOI] [Google Scholar]
  • 46.Hotra O.Z., Samila A.P., Rozorinov H.M., Hres O.V. Current status and development prospects of nuclear quadrupole resonance pulsed spectroscopy methods: A review. Telecommun. Radio Eng. 2019;78:1483–1496. doi: 10.1615/TelecomRadEng.v78.i16.60. [DOI] [Google Scholar]
  • 47.Peyvasteh M., Tryfonyuk L., Ushenko V., Syvokorovskaya A.V., Dubolazov A., Vanchulyak O., Ushenko Y., Gorsky M., Meglinski I. 3D Mueller-matrix-based azimuthal invariant tomography of polycrystalline structure within benign and malignant soft-tissue tumours. Laser Phys. Lett. 2020;17:115606. doi: 10.1088/1612-202X/abbee0. [DOI] [Google Scholar]
  • 48.Ushenko V.O., Trifonyuk L., Ushenko Y.A., Dubolazov O.V., Gorsky M.P., Ushenko A.G. Polarization singularity analysis of Mueller-matrix invariants of optical anisotropy of biological tissues samples in cancer diagnostics. J. Opt. 2021;23:064004. doi: 10.1088/2040-8986/abf97a. [DOI] [Google Scholar]
  • 49.Trifonyuk L., Strashkevich A., Pavlyukovich N., Pavlyukovich A., Tomka Y., Zhitaryuk V., Tkachuk V.I. Polarization interference mapping of microscopic images of protein fluorofores in the differential diagnosis of benign and malignant prostate tumours. Proc. SPIE Int. Soc. Opt. Eng. 2021;12126:1212628. [Google Scholar]
  • 50.Trifonyuk L., Strashkevich A., Kozlov S., Davidenko I., Poliansky I., Pavlyukovich N., Pavlyukovich A., Tomka Y., Fesiv I.V., Ushenko Y.A., et al. Digital microscopic mapping of laser induced polarization ellipticity maps in differential diagnostics of preparations of benign and malignant prostate tumours. Proc. SPIE Int. Soc. Opt. Eng. 2021;12126:1212629. [Google Scholar]
  • 51.Kvasniuk D., Trifonyuk L., Strashkevich A., Kozan N., Ushenko V., Dunaiev O., Kryvetskyi V., Oliinyk I., Kurek E.I., Tkachuk V.I. Detection of pathological changes in the architectonics of polycrystalline blood films using laser-induced polarization interferometry. Proc. SPIE Int. Soc. Opt. Eng. 2021;12126:1212629. [Google Scholar]
  • 52.Cui T.J., Liang C.H., Wiesbeck W. Closed-Form Solutions for One-Dimensional Inhomogeneous Anisotropic Medium in a Special Case—Part II: Inverse Scattering Problem. IEEE Trans. Antennas Propag. 1997;45:942–948. [Google Scholar]
  • 53.Valagiannopoulos C. On measuring the permittivity tensor of an anisotropic material from the transmission coefficients. Prog. Electromagn. Res. B. 2008;9:105–116. doi: 10.2528/PIERB08072005. [DOI] [Google Scholar]
  • 54.Bedair A., Okasha K., Mansour F.R. Spectroscopic methods for COVID-19 detection and early diagnosis. Virol. J. 2022;19:152. doi: 10.1186/s12985-022-01867-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 55.Gori F., Santarsiero M., Vicalvi S., Borghi R., Guattari G. Beam coherence-polarization matrix. Pure Appl. Opt. 1998;7:941–951. doi: 10.1088/0963-9659/7/5/004. [DOI] [Google Scholar]
  • 56.Tervo J., Setala T., Friberg A. Two-point Stokes parameters: Interpretation and properties. Opt. Lett. 2009;34:3074–3076. doi: 10.1364/OL.34.003074. [DOI] [PubMed] [Google Scholar]
  • 57.Robinson S.P. Principles of Forensic Medicine. Greenwich Medical Media; London, UK: 1996. p. 206. [Google Scholar]
  • 58.He C., He H., Chang J., Chen B., Booth M.J. Polarisation optics for biomedical and clinical applications: A review. Light Sci. Appl. 2021;10:194. doi: 10.1038/s41377-021-00639-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 59.Adhikari A., Dev K., Asundi A. Subwavelength metrological chracterization by Mueller matrix polarimeter and finite difference time domain method. Opt. Lasers Eng. 2016;86:242–247. doi: 10.1016/j.optlaseng.2016.06.014. [DOI] [Google Scholar]
  • 60.Heinrich C., Rehbinder J., Nazac A., Teig B., Pierangelo A., Zallat J. Mueller polarimetric imaging of biological tissues: Classification in a decisiontheoretic framework. J. Opt. Soc. Am. A. 2018;35:2046. doi: 10.1364/JOSAA.35.002046. [DOI] [PubMed] [Google Scholar]
  • 61.Dong Y., Wan J., Wang X., Xue J.-H., Zou J., He H., Li P., Hou A., Ma H. A Polarization-Imaging-Based Machine Learning Framework for Quantitative Pathological Diagnosis of Cervical Precancerous Lesions. IEEE Trans. Med. Imaging. 2021;40:3728–3738. doi: 10.1109/TMI.2021.3097200. [DOI] [PubMed] [Google Scholar]
  • 62.Rovira J.R., Pavlov S.V., Vassilenko V.B., Wójcik W., Sugurova L. Proceeding SPIE, Optical Fibers and Their Applications. Volume 8698. SPIE; Bellingham, WA, USA: 2013. Methods and resources for imaging polarimetry; pp. 216–219. [Google Scholar]
  • 63.Dubolazov A.V., Koval G.D., Zabolotna N.I., Pavlov S.V. Fractal structure of optical anisotropy Mueller-matrices images of biological layers; Proceedings of the Eleventh International Conference on Correlation Optics; Chernivtsi, Ukraine. 17 December 2013; [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The data presented in this study are available on request from the corresponding author. As the research involves human tissue, the availability of data is subject to the decision of the relevant ethics committee.


Articles from Sensors (Basel, Switzerland) are provided here courtesy of Multidisciplinary Digital Publishing Institute (MDPI)

RESOURCES