Abstract
The dynamics and fusion of vesicles during the last steps of exocytosis are not well established yet in cell biology. An open issue is the characterization of the diffusion process at the plasma membrane. Total internal reflection fluorescence microscopy (TIRFM) has been successfully used to analyze the coordination of proteins involved in this mechanism. It enables to capture dynamics of proteins with high frame rate and reasonable signal-to-noise values. Nevertheless, methodological approaches that can analyze and estimate diffusion in local small areas at the scale of a single diffusing spot within cells, are still lacking. To address this issue, we propose a novel correlation-based method for local diffusion estimation. As a starting point, we consider Fick’s second law of diffusion that relates the diffusive flux to the gradient of the concentration. Then, we derive an explicit parametric model which is further fitted to time-correlation signals computed from regions of interest (ROI) containing individual spots. Our modeling and Bayesian estimation framework are well appropriate to represent isolated diffusion events and are robust to noise, ROI sizes, and localization of spots in ROIs. The performance of BayesTICS is shown on both synthetic and real TIRFM images depicting Transferrin Receptor proteins.
Keywords: Bayesian methods, diffusion, estimation, fluorescence microscopy, temporal correlation spectroscopy
Impact Statement
This paper presents an original Bayesian method to analyze fluorescent spots diffusing at the cell membrane and observed in time-lapse fluorescence microscopy. Unlike related temporal correlation spectroscopy methods, BayesTICS adapts locally and is robust to low signal-to-noise ratios and sizes of regions of interest.
1. Introduction
In cell biology, diffusion measurements are commonly used to compare several compartments within a cell or in different cells (e.g., neuronal synapses or HeLa cells). At the scale of a single cell, free diffusion of proteins (i.e., molecules undergoing Brownian motion) often corresponds to the main mode of molecular transport. The analysis of intracellular diffusion provides information about both the dynamics of the proteins and the cellular medium in which they evolve. Several techniques have been developed to quantify the dynamics of fluorescently-tagged proteins (e.g., Green Fluorescent Proteins [GFP]) in live cell imaging and to estimate diffusion coefficients from fluorescence microscopy data, that were adapted to different purposes. The two main types of techniques are single-particle techniques and ensemble measurement techniques, both allowing for the analysis of molecular dynamics, each having their advantages and limitations as described below.
Single-particle tracking (SPT) approaches are particularly recommended when the experimental setup is available, as the trajectory of a single molecule provides a quantitative description of motion in space and time. Given tracks obtained by nearest neighborhood algorithms or more sophisticated tracking methods( 1 ), the mean-square displacement (MSD) of tracks is generally used to interpret and detect free diffusion, confined diffusion, and directed flow( 2 ). The theoretical limits of SPT, in particular for confined diffusion, have been established in Ref. (3). SPT-based approaches require labeling single molecules with suitably high signal/noise marker particles, as well as high-speed and high-sensitivity microscopes. Tracking errors due to imperfect algorithms can also limit the applicability of this technique.
Fluorescence correlation approaches are valuable techniques that provide quantitative information on both large and small-scale intracellular dynamics without individual object tracking. In the original fluorescence correlation spectroscopy (FCS) method( 4 – 6 ), temporal fluctuations of fluorescent molecules in a region of interest (ROI) are used to measure the local concentration of the observed population. A correlation method is used to analyze 1D signals of temporal fluctuations. The main drawback of FCS is related to the photobleaching of the fluorescently-tagged molecules that limits the acquisition time and, thus, the applicability to fast dynamics. A related approach consists in analyzing the fluorescence recovery after photobleaching (FRAP)( 7 ) in a specified area by a high-intensity laser pulse and is used to quantify two-dimensional lateral diffusion and protein binding. The fluorescence recovery curves are fitted to a theoretical model by using a nonlinear least squares algorithm( 8 ). However, reliable estimation of the parameters requires several experimental curves that might introduce numerical and experimental repetition errors. The major limitations of both FCS and FRAP are related to strong sensitivity to the signal-to-noise ratio (SNR) and the need for spatial and temporal stationarity of dynamics in the ROI.
Another approach that is derived from fluorescence correlation techniques and overcomes some of FCS limitations is temporal image correlation spectroscopy (TICS)( 9 ). With TICS, one can measure the concentration of molecules in the image as well as dynamical properties such as the characteristic time of diffusion. TICS is based on the same principles as FCS but exploits 2D temporal signals instead of 1D temporal signals, and can detect diffusion and flow at the same time. Spatio-temporal image correlation spectroscopy (STICS)( 10 ) extended the applicability of TICS to recover direction flow of moving molecules. Other derived methods were developed for specific purposes, such as spatio-temporal image cross-correlation spectroscopy (STICCS)( 11 ) that can detect and characterize the dynamics of two species in the ROI, reciprocal space image correlation spectroscopy (kICS)( 12 ) that solves the issue of sensitivity to photobleaching and blinking of the fluorescent molecules of STICS or, more recently, pair correlation function FCS (pCF)( 13 ) that is able to detect barriers of diffusion. While a wide range of applications is covered by these correlation-based methods, they still require a low concentration of molecules in the region of focus and a temporal stationarity of the fluorescence signals( 10 , 14 ), which is not always satisfied in experimental data.
All the aforementioned methods are either computationally demanding or come with a high sensitivity to parameters such as SNR or ROI size. Moreover, standard correlation-based methods require a previous knowledge of the point spread function (PSF) that is not always available, and need a minimum window size, which makes it impossible to estimate the diffusion coefficient on very small ROIs. Thus, analyzing diffusion in small inhomogeneous regions of the cell from regular 2D fluorescent microscopy data is still a real challenge.
In this paper, we address the issue of estimating locally constant but spatially varying diffusion coefficients of fluorescently-tagged membrane proteins close to the plasma membrane (PM). Experimental data is acquired by total internal reflection fluorescence (TIRF) microscopy, a technique vastly used for imaging protein dynamics within thin layers( 15 , 16 ). We propose two models of the autocorrelation function of the 2D temporal fluorescent signal and a Bayesian framework (approximate Bayesian computation (ABC)( 17 )) for robustly estimating the local diffusion coefficient. We show that the proposed method complements previous techniques by providing distinct advantages of local analysis over TICS counterparts on ROIs. Moreover, the method does not rely on a temporal stationarity hypothesis of the fluorescent signal or an accurate measurement of PSF of the imaging system. Unlike previous methods based on nonlinear model fitting( 18 ), BayesTICS is based on the simulation of time-correlation signals and provides the posterior distribution of diffusion coefficient that can be exploited to analyze changes in dynamics, or in the local environment of the membrane.
This paper is organized as follows. In the next section, we describe the diffusion and image models with initial conditions, the closed-form solution and approximations, including the ABC-based algorithm to estimate local diffusion coefficients from time-correlation signals computed over ROIs. In the experimental section, we demonstrate the robustness of BayesTICS to SNRs on simulated and real images depicting Transferrin Receptor (TfR) dynamics (labeled with pHluorin, a pH-sensitive derivative of GFP) at the PM during the late steps of exocytosis, that is, diffusion in the PM after vesicle fusion. We evaluate the sensitivity to both nuisance parameters (e.g., size of ROIs) and the algorithm parameters, and we assess the accuracy of BayesTICS on simulated data. Our approach further extends the capability of correlation spectroscopy methods and provides, to our knowledge, a new tool for the quantitative characterization of molecular dynamics in living cells.
2. Method
2.1. Diffusion model and image generation
Diffusion of transmembrane proteins is mainly modeled by lateral diffusion in the membrane( 19 ). This phenomenon may be described by Fick’s second law( 20 ):
| (1) |
where
denotes the concentration of molecules at time
and at location
,
being the ROI in the image domain, and
is the Laplacian operator. In our modeling framework, the diffusion coefficient
in (1) is assumed to be constant over
. In addition, we assume that all the proteins are concentrated at the center
of
, at initial time
, that is
where
is the Kronecker symbol and
is the initial concentration of molecules. With the aforementioned initial conditions, the closed-form solution is well established and given by(
21
,
22
):
![]() |
(2) |
Define
, and denote
the fluorescence intensity at time
and spatial position
. The fluorescence intensity is assumed to be proportional (with factor
) to the convolution (denoted
) of the microscopic number density (or concentration)
and the instrumental “PSF”
:
| (3) |
where
,
is the efficiency of the instrument to collect photons,
is the molecular absorption coefficient, and
is the quantum yield of the fluorophore. If we assume that the PSF is approximated with a 2D Gaussian function with an isotropic bandwidth
in the lateral direction, we get (see Refs. 18,23) and Supplementary Appendix A):
![]() |
(4) |
with
.
2.2. Local temporal image correlation spectroscopy
In this section, we describe our correlation-based method, inspired from FCS, to compute local diffusion in fluorescence images. For this purpose, we need to compute the temporal autocorrelation of images to capture temporal fluctuations of intensities.
2.2.1. Uniform background
First, we are interested in locally estimating the diffusion of an isolated spot over a uniform background (i.e., for a long enough sequence, the spatiotemporal average of
is zero). In that case, the process associated with the image sequence is not stationary. Accordingly, the autocorrelation function is real-time dependent and not only delay-dependent. Hence, we use the following expectation formula for the autocorrelation function:
![]() |
(5) |
where
is the temporal lag and denote the spatial average. By substituting
with (4) in (5), we get (see details in Supplementary Appendix B):
![]() |
(6) |
Note that if we consider the inverse of the autocorrelation function,
can be approximated as a linear function of unknown parameters
and
(see details in Supplementary Appendix B):
| (7) |
2.2.2. Nonuniform and cluttered background
In order to account for nonuniform background and the potential presence of neighboring spots diffusing in the ROI
, let us assume that the spatiotemporal average of
is nonzero. Hence, we consider the following expectation formula for the intensity fluctuation autocorrelation function:
![]() |
(8) |
where
. By replacing
in (8) with the expression given in (4), we obtain (see details in Supplementary Appendix C):
| (9) |
where
![]() |
Model
can then be considered as an extension of the model
. In (6) and (9), the ROI size
is a multiplicative factor and can be interpreted as a scaling parameter. We shall see that the ROI size does not influence the estimation of
in our experiments provided there is a single spot in the ROI. Unlike (6), the total time of observation
appears in
and
and may thus influence the estimation of
. Nevertheless, this impact is minimal for
large enough, as one has
Finally, the extended model
can be interpreted as an “out of equilibrium” state of the observed system, that allows us to take into account perturbations such as noisy data, nonuniform background, or other spots diffusing in the image.
2.3. Bayesian estimation of model parameters
Model
, as given by (9), depends on the values of
and
in a highly nonlinear fashion. As a result, the estimation of the involved parameters performed by maximizing the underlying likelihood (or minimizing the corresponding data fidelity term) may be very complex or even not tractable. Nevertheless, we can resort by applying a computational Bayesian approach described in what follows.
2.3.1. Principles of ABC
The ABC method( 17 ) relies on stochastic simulation that generates samples and selects those that follow the posterior distribution. This approach allows us to compute both the maximum a posteriori estimator and the a posteriori expectation from the selected samples.
Formally, let us assume that a given discrete observation
is generated from a model with parameters
whose prior is denoted by
. The posterior distribution of interest is defined by
where
. The success of the rejection ABC method(
17
) depends on the fact that the underlying stochastic process is easy to simulate for a given set of parameters. The ABC procedure can be summarized as below:
Generate
from the prior distribution
;Simulate
from the model with parameter
;Compute the distance
between
and
;Accept
with probability
and return to 1.
Here
is a constant chosen to guarantee that
defines a probability:
![]() |
The observation
and the simulation
are real-valued arrays of matching dimension and
evaluates the distance between them.
As mentioned above, this approach requires the design of a suitable metric
, as well as the choice of an adapted value for
. The choice of
depends on the given problem. However, standard metrics, such as the
norm, are used in a significant number of problems. As for the choice of
, one may note that, when
tends to
, the accepted samples come from the prior, while when
, the accepted samples follow the target posterior distribution
. Therefore, the choice of
reflects the balance between computability and accuracy. For a given
and
, accepted samples are independent and identically distributed from
.
The next step is to compute posterior expectation defined as
, which is known as the minimum mean square error (MMSE) estimator. The simplest way to compute the MMSE estimator is to draw
samples
, from
using the algorithm above and compute the empirical averages
. The samples can also be exploited to compute the posterior distribution for which the maximum mode equals the maximum a posteriori (MAP) estimator
. There are several advantages to this rejection method, among them the fact that they are usually easy to code, and they generate independent samples.
2.3.2. ABC algorithm and implementation details
In our context, the observation
is the autocorrelation (5) or (8) approximated in the discrete setting from the fluorescent intensities
, in a given ROI
, as follows:
![]() |
(10) |
where
denotes a pixel location in
,
and
are the width and height of the ROI (
),
, and
. The simulated sample
is the autocorrelation simulated from the model (6) and (9) with parameter
.
We implemented the ABC rejection-based method with 0–1 cut-off and the distance
(see Algorithm 1). The algorithm takes as input an image sequence, also denoted
, and computes
as explained above. Then, it uses the ABC procedure to compute the estimates
and
.
Algorithm 1:
BayesTICS algorithm
We now discuss how the parameters of BayesTICS can be selected. The prior distribution of both parameters
and
is assumed to be uniform on intervals depending on the underlying biological process. Typically,
and
. The number
is set to 100, 000 samples. The cut-off value
is set so as to accept 1 to 5% of the samples (about the best 1000 samples) which serve to compute the posterior distribution,
, and
.
The algorithm is relatively fast as each sample
from (6) or (9) takes about 0.001 s to generate. Moreover, all the simulated samples in a ROI are independent and can be generated in parallel. This means that the processing of multiple ROIs in an image sequence can be performed very efficiently.
3. Experimental Results
In this section, we evaluate the performance of BayesTICS on synthetic and real images depicting multiple diffusing spots at the PM observed in TIRF microscopy as illustrated in Figure 1. We applied the BayesTICS algorithm to compute the MAP and MMSE estimators of the diffusion coefficient by considering the two models (6) and (9), respectively. The ROI size depends on the spot size and here is set to
pixels windows from the analysis of real images. Meanwhile, the temporal series should be long enough to observe stationary fluctuations. In our experiments,
time points. As these choices may involve some arbitrariness, we assessed the sensitivity to
and
, as well as the position of the spot of interest in the ROI. In what follows, we show that changes in these parameters lead to essentially similar results and demonstrate the robustness of BayesTICS with respect to noise levels and cluttered background (i.e., presence of multiple spots in a ROI). We focus on the estimation of
which is the parameter of interest.
Figure 1.
Microscopy image depicting diffusing pHluorin-tagged spots at the PM observed in TIRF microscopy (courtesy of PICT facility, UMR144-CNRS Institut Curie).
3.1. Evaluation on simulated data
First, in order to test the robustness of BayesTICS to noise, we simulated six image sequences depicting an isolated diffusion spot in a ROI
of
pixels, with a diffusion coefficient equal to
pixel/frame. The image intensities were then corrupted with Gaussian white noise with different standard deviations yielding image sequences with different SNRs. Figure 2 shows the 2D images at time
(left) extracted from the six image sequences and the autocorrelation plots (middle and right). We reported the results of BayesTICS, that is the posterior distributions,
, and
for the two autocorrelation models
and
, respectively. The results suggest that the performance of estimators
pixel/frame and
pixel/frame for
, and
pixel/frame and
pixel/frame for
, are hardly influenced by the amount of noise in the images. We observe that the MMSE values are slightly higher than the true diffusion coefficient (
pixel/frame) for both models.
Figure 2.
Robustness of the BayesTICS method to noise level with a fixed window size. Five different ROIs with increasing amount of noise (from top to bottom, and from left to right) were simulated. (a) The ROIs at time
are extracted from five simulated sequences composed of
frames (
pixels images) and depicting 2D diffusing spots with a theoretical diffusion coefficient
pixel/frame. The size of ROIs is set to
pixels and the spots are located at the center of each ROI. (b) The autocorrelation versus time lag plot is shown for
and
models. Each plot shows the observed autocorrelation (black curve), and two autocorrelation samples generated from the
and
models with the
and
parameters (green and magenta curves). (c) The estimated posterior distributions are displayed for
and
for the ROI with intermediate noise level.
Furthermore, we evaluated the influence of the ROI size, the spot position in ROIs, and the amount of noise in ROIs. We analyzed six different ROIs shown in Figure 3. The spot of interest (red circle) is not located at the center of the ROI. The size of the ROI varies from small regions to large square/rectangle windows which may contain background and additional spots. The SNR changes from low values (upper-left image in Figure 3) to high values (lower-right image in Figure 3). In this experiment, we obtained
pixel/frame and
pixel/frame for
, and
pixel/frame and
pixel/frame for
, while
pixel/frame. Both MAP and MMSE estimators display a certain variance and inaccuracy that is due to the background environment in the ROI. Supplementary Figures 1–3 show that the change in ROI size or in spot position do not influence significantly the estimation, but a combined effect with the background clutter in the ROI can potentially diminish the accuracy of the estimation. Interestingly, both MAP and MMSE estimators from model
are more accurate than the estimation from
, suggesting that model (9) is better suited for spots in complex environments than model (6).
Figure 3.
Robustness of the BayesTICS method to noise level with variable spot position, and window size. (a-f) Six different cases with varying noise level, spot position, and window size were tested. They were extracted from six simulated sequences of 2D diffusing spots, with
pixels window size, total length of
frames, a theoretical diffusion coefficient of
pixels/frame. For each case, the z-projection of the maximum intensity of the simulated stack and the autocorrelation versus time lag plot is shown. The spot of interest is market in purple, and can be anywhere in the ROI. Other spots can be in the ROI, diffusing or not. The size of the ROI has the following values (from a to f):
,
,
,
,
,
pixels. Each plot shows the computed autocorrelation from the data (dark gray), generated autocorrelations for the BayesTICS method (green). The two estimates
and
for the diffusion coefficient are given on the corresponding plots.
3.2. Experiments on real data: TfR molecules diffusion at different locations at the plasma membrane
We assessed the BayesTICS algorithm on real data total internal reflection fluorescence microscopy (TIRFM) 2D image sequences depicting TfR proteins tagged with pHluorin in M10 cells, at the late steps of exocytosis, that is when the vesicles fuse with the PM. TfR is a transmembrane protein known to diffuse at the PM, and serves here as a reference biological model. PHluorin is pH-sensitive and is helpful here to determine the accurate time-point when the fusion starts. This probe was already used in previous studies(
23
,
24
). We considered 2D TIRFM sequences composed of
images of size
pixels (see Figure 1), acquired with a frame rate of
frames/s.
Local diffusion events are first detected at the PM with an appropriate algorithm(
18
,
23
) (or manually selected by an user) and several temporal series of ROIs with the same size
are automatically extracted as illustrated in Figure 4. The nonuniform fluorescent background in
is estimated as the median of the intensity values, over 20 frames, and further subtracted to reduce bias in the estimation of diffusion. The initial time point
is automatically found in our experiments by detecting the frame in which the fluorescence intensity is maximal in the temporal sequence. For a given ROI, the frames with index
are discarded. The value of
is set to
and
for computing
and
, respectively. As the background is subtracted from the last few dozen frames,
must be chosen as to keep the end of the sequence free of other diffusing spots. As long as this condition is satisfied,
can be tuned according to the underlying diffusion speed. Finally, we assume that the images are corrupted by white Gaussian noise. A variance stabilizing transform (Generalized Anscombe transform(
24
)) is potentially applied to produce a normally distributed noise(
25
).
Figure 4.
Evaluation of BayesTICS on real TIRF image sequences depicting TfR proteins tagged with pHluorin (pH-sensitive probe) in M10 cells. (a) Five
pixels ROIs were selected (left). (b) The autocorrelation versus time lag plot are shown for
and
models. Each plot shows the observed autocorrelation (black curve), and two autocorrelation samples generated from the
and
models with the
and
parameters (green and magenta curves). (c) The estimated posterior distributions are displayed for
(left) and
(right) for Spot s5.
We selected five ROIs (s1,s2, s3, s4, s5) in the image shown in Figure 1 which contain a diffusing spot and variable background. We applied BayesTICS to compute the posterior distributions of
and
and the MAP and MMSE estimators by considering the two models
and
. In the present situation, the MAP and MMSE estimators (
,
) computed with the
model are more consistent with those published in the literature(
18
,
23
).
4. Conclusion
In this paper, we have proposed a novel method, named BayesTICS, to estimate local 2D diffusion observed in TIRF microscopy from temporal series of images acquired for typical temporal correlation measurements. BayesTICS was specifically designed for local estimation, as opposed to other methods such as FRAP or FCS that provide a global estimator for the entire image. We assume that the diffusion coefficient is constant in the region of interest, that is, for each diffusing spot, but not necessarily constant across the entire image. BayesTICS may be helpful to confirm if diffusion is homogeneous or heterogeneous across several spots. In our approach, the fluorescent intensity and a nonstationary initial diffusion model are used to compute the autocorrelation function of the sequence. This function is then used in a correlation-based Bayesian framework providing the posterior distribution of the diffusion coefficient. Two models are proposed: one for isolated diffusing spots without background (
), and one for nonisolated diffusing spots with crowded background (
). The efficiency and accuracy of the method are demonstrated on extensive simulated sequences, then applied to experimental data.
By applying the BayesTICS method to the diffusion of TfR molecules during the fusion of vesicles to the PM in exocytosis, we showed that this method is able to properly handle a wide variety of situations, yielding results that are consistent and in accordance with previously reported results. The results show that the apparent diffusion coefficient varies slightly between the different spots, which is helpful here to detect local variations in the environment of the diffusing spot. In Supplementary Figure 4, we illustrate BayesTICS in a complementary study focused on the interactions between TfR and Rab11 proteins that dissociate or diffuse close to the PM. Our method suggests that a small fraction of the detected Rab11 spots display apparent diffusion at the PM. These preliminary results need to be confirmed with alternative and complementary estimation techniques as currently investigated in an on-going project.
BayesTICS is a fast and simple-to-implement method for local diffusion quantification from TIRF microscopy data. Its main advantages are that it uses standard TIRF microscopy acquisition, and only needs a single sequence to estimate local diffusing with little preprocessing. This both reduces experimental setup costs and avoids extra numerical errors that come from repeating experiments and from complex pre or postprocessing. This method is also robust to variable SNRs, to the choice of the size of the analysis window, and to the location of the spot of interest in the ROI. Two limitations remain: the method requires long acquisition sequences (at least 100 frames for
and 300 frames for
), which is due to the correlation basis itself and, it is sensitive to dynamic interferences in the ROI, which could be improved by introducing the appropriate dynamic initial model to include other types of diffusion. While BayesTICS is currently designed to detect 2D diffusion only, its extension to 3D and, in particular, its application to 3D multi-angle TIRFM(
26
) are envisioned, in order to better decipher the late steps of the exocytosis mechanisms.
Acknowledgments
We warmly thank L. Leconte and J. Salamero for discussions and suggestions to improve the manuscript, as well as the PICT imaging platform of Institut Curie, member of the France-BioImaging infrastructure (ANR-10-INBS-04-01), for providing real TIRM image sequences.
Competing Interests
The authors declare no competing interests exist.
Authorship Contributions
C.K. devised the project and the main conceptual ideas, supervised the project, and was in charge of overall direction and planning. A.C. designed and implemented the presented BayesTICS, in discussions with Y.L.C. A.C. performed experiments on artificial datasets and real images. A.C. and C.K. cowrote the manuscript. All authors provided critical feedback and helped shape the research, analysis, and manuscript.
Funding Statement
This research was supported by a grant from the French Ministry of Research and Innovation (MESRI).
Supplementary material
For supplementary material accompanying this paper visit https://doi.org/10.1017/S2633903X23000041.
click here to view supplementary material
References
- 1.Chenouard N, Smal I, De Chaumont F, et al. (2014) Objective comparison of particle tracking methods. Nature Methods 11(3), 281–289. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Qian H, Sheetz M & Elson E (1991) Single particle tracking: analysis of diffusion and flow in two-dimensional system. Biophysical J 60, 910–921. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Bickel T (2007) A note on confined diffusion. Phys A Stat Mech App 377(1), 24–32. [Google Scholar]
- 4.Elson E & Magde D (1974) Fluorescence correlation spectroscopy. I. conceptual basis and theory. Biopolymers 13(1), 1–27. [DOI] [PubMed] [Google Scholar]
- 5.Magde D, Elson E & Webb W (1972) Thermodynamic fluctuations in a reacting system—measurement by fluorescence correlation spectroscopy. Phys Rev Lett 29(11), 705. [Google Scholar]
- 6.Magde D, Elson E & Webb W (1974) Fluorescence correlation spectroscopy. II. An experimental realization. Biopolymers 13(1), 29–61. [DOI] [PubMed] [Google Scholar]
- 7.Axelrod D, Koppel D, Schlessinger J, Elson E & Webb W (1976) Mobility measurement by analysis of fluorescence photobleaching recovery kinetics. Biophysical J 16(9), 1055–1069. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Soumpasis D (1983) Theoretical analysis of fluorescence photobleaching recovery experiments. Biophysical J 41(1), 95–97. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Wiseman P, Squier J, Ellisman M & Wilson K (2000) Two-photon image correlation spectroscopy and image cross-correlation spectroscopy. J Microscopy 200(1), 14–25. [DOI] [PubMed] [Google Scholar]
- 10.Hebert B, Costantino S & Wiseman P (2005) Spatiotemporal image correlation spectroscopy (stics) theory, verification, and application to protein velocity mapping in living cho cells. Biophysical J 88(5), 3601–3614. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Schwille P, Meyer-Almes F-J & Rigler R (1997) Dual-color fluorescence cross-correlation spectroscopy for multicomponent diffusional analysis in solution. Biophysical J 72(4), 1878–1886. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Kolin D, Ronis D & Wiseman P (2006) k-space image correlation spectroscopy: a method for accurate transport measurements independent of fluorophore photophysics. Biophysical J 91(8), 3061–3075. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Malacrida L, Hedde P, Ranjit S, Cardarelli F & Gratton E (2018) Visualization of barriers and obstacles to molecular diffusion in live cells by spatial pair-cross-correlation in two dimensions. Biomedical Opt Express 9(1), 303–321. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Ji L & Danuser G (2005) Tracking quasi-stationary flow of weak fluorescent signals by adaptive multi-frame correlation. J Microscopy 220(3), 150–167. [DOI] [PubMed] [Google Scholar]
- 15.Axelrod D (2001) Total internal reflection fluorescence microscopy in cell biology. Traffic 2(11), 764–774. [DOI] [PubMed] [Google Scholar]
- 16.Burchfield J, Lopez J, Mele K, Vallotton P & Hughes W (2010) Exocytotic vesicle behaviour assessed by total internal reflection fluorescence microscopy. Traffic 11(4), 429–439. [DOI] [PubMed] [Google Scholar]
- 17.Beaumont M, Zhang W & Balding D (2002) Approximate Bayesian computation in population genetics. Genetics 162, 2025–2035. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Basset A, Bouthemy P, Boulanger J, Waharte F, Salamero J & Kervrann C (2017) An extended model of vesicle fusion at the plasma membrane to estimate protein lateral diffusion from TIRF microscopy images. BMC Bioinformatics 18, 352. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Almeida P & Vaz W (1995) Lateral diffusion in membranes. In Handbook of Biological Physics, Vol. 1, pp. 305–357. Amsterdam: Elsevier. [Google Scholar]
- 20.Philibert J (2005) One and a half century of diffusion: Fick, einstein, before and beyond. Diffusion Fundamentals 2(1), 1–10. [Google Scholar]
- 21.Crank J (1975) The Mathematics of Diffusion. Oxford: Clarendon Press. [Google Scholar]
- 22.Seiffert S & Oppermann W (2005) Systematic evaluation of frap experiments performed in a confocal laser scanning microscope. J Microscopy 220(1), 20–30. [DOI] [PubMed] [Google Scholar]
- 23.Basset A, Bouthemy P, Boulanger J, Waharte F, Kervrann C & Salamero J (2015) Detection and estimation of membrane diffusion during exocytosis in TIRFM image sequences. In Proceedings IEEE International Symposium on Biomedical Imaging (ISBI), pp. 695–698. New York: IEEE. [Google Scholar]
- 24.Boulanger J, Kervrann C, Bouthemy P, Elbau P, Sibarita JB & Salamero J (2010) Patch-based nonlocal functional for denoising fluorescence microscopy image sequences. IEEE Trans Med Imaging 29(2), 442–454. [DOI] [PubMed] [Google Scholar]
- 25.Basset A, Boulanger J, Salamero S, Bouthemy P & Kervrann C (2015) Adaptive spot detection with optimal scale selection in fluorescence microscopy images. IEEE Trans Image Process 24(11), 4512–4527. [DOI] [PubMed] [Google Scholar]
- 26.Boulanger J, Gueudry C, Münch D, et al. (2014) Fast high-resolution 3D total internal reflection fluorescence microscopy by incidence angle scanning and azimuthal averaging. Proc Natl Acad Sci USA 111(48), 17164–17169. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
For supplementary material accompanying this paper visit https://doi.org/10.1017/S2633903X23000041.
click here to view supplementary material













