Abstract
Purpose
The objective of this study was to implement a 5-minute MRI protocol for the shoulder in routine clinical practice consisting of accelerated 2D turbo spin echo (TSE) sequences with deep learning (DL) reconstruction at 1.5 and 3 Tesla, and to compare the image quality and diagnostic performance to that of a standard 2D TSE protocol.
Methods
Patients undergoing shoulder MRI between October 2020 and June 2021 were prospectively enrolled. Each patient underwent two MRI examinations: first a standard, fully sampled TSE (TSES) protocol reconstructed with a standard reconstruction followed by a second fast, prospectively undersampled TSE protocol with a conventional parallel imaging undersampling pattern reconstructed with a DL reconstruction (TSEDL). Image quality and visualization of anatomic structures as well as diagnostic performance with respect to shoulder lesions were assessed using a 5-point Likert-scale (5 = best). Interchangeability analysis, Wilcoxon signed-rank test and kappa statistics were performed to compare the two protocols.
Results
A total of 30 participants was included (mean age 50±15 years; 15 men). Overall image quality was evaluated to be superior in TSEDL versus TSES (p<0.001). Noise and edge sharpness were evaluated to be significantly superior in TSEDL versus TSES (noise: p<0.001, edge sharpness: p<0.05). No difference was found concerning qualitative diagnostic confidence, assessability of anatomical structures (p>0.05), and quantitative diagnostic performance for shoulder lesions when comparing the two sequences.
Conclusions
A fast 5-minute TSEDL MRI protocol of the shoulder is feasible in routine clinical practice at 1.5 and 3 T, with interchangeable results concerning the diagnostic performance, allowing a reduction in scan time of more than 50% compared to the standard TSES protocol.
Keywords: Acceleration, Magnetic resonance imaging, Deep learning reconstruction, Image processing, Diagnostic imaging
Highlights
-
•
MRI has become the most commonly used imaging modality for patients with shoulder pain.
-
•
Deep learning TSE reduces the scan time for the shoulder to 5 minutes.
-
•
Deep learning TSE provides significant improvement of noise and image quality.
-
•
Diagnostic performance of Deep Learning and standard TSE is interchangeable.
-
•
This immense reduction in scan time increases patient throughput and patient comfort.
1. Introduction
Magnetic resonance imaging (MRI) of the shoulder has become the most commonly used imaging modality in patients with shoulder pain due to its ability to enable comprehensive noninvasive diagnosis of pathologies such as rotator cuff or biceps tendon tears, and glenoid labral abnormalities [1], [2]. Standard MRI protocols for shoulder imaging consist of two-dimensional (2D) turbo spin-echo (TSE) sequences in three planes. A disadvantage of these comprehensive protocols is the long acquisition time of approximately 10–20 minutes. Methods to accelerate shoulder MRI acquisition primarily involve parallel imaging (PI), compressed sensing (CS), or three-dimensional (3D) MR sequences at high-resolution [3], [4], [5], [6], [7]. However, a major disadvantage of PI is the substantially lower signal-to-noise ratio (SNR) when accelerating sequences and, regarding 3D-sequences, the suboptimal tissue contrast [6].
Recently, novel MRI reconstruction techniques based on deep learning (DL) have been introduced and have revolutionized the trade-off between shortening acquisition time and maintaining image quality. The efficiency of DL acceleration for TSE-sequences has previously been evaluated for MRI protocols in musculoskeletal imaging of different joints, including protocols for shoulder imaging [8], [9], [10], [11], [12], [13], [14]. However, studies on the clinical implementation at 1.5 and 3 T and particularly on diagnostic performance in clinical practice for shoulder MRI are still scarce.
We hypothesize that a DL-reconstruction for TSE imaging of the shoulder is feasible in routine clinical practice and may allow for a significant reduction of examination time with comparable image quality and interchangeable diagnostic performance compared with standard imaging.
Therefore, the aim of this study was to implement a fast 5-minute shoulder MRI protocol consisting of accelerated 2D TSE sequences with DL-reconstruction at 1.5 and 3 T in daily clinical practice and to compare the image quality and diagnostic performance in terms of detection of common shoulder pathologies to that of a standard 2D TSE protocol.
2. Materials and methods
2.1. Study design
This single-center prospective study was approved by the institutional review board (clinical trial registry number: DRKS00023278) and written informed consent was obtained from all participants. All study procedures were in accordance with the Declaration of Helsinki and its subsequent amendments. Patients undergoing native MRI of the shoulder were consecutively enrolled in the study between October 2020 and June 2021. Inclusion criteria were clinically indicated shoulder MRI on appropriate scanners with the DL-reconstruction algorithm installed. Exclusion criteria were age under 18 years, application of contrast agents, nonconditional implants, and severe claustrophobia. The final sample included 30 participants (see Fig. 1 and Table 1).
Fig. 1.
Flow diagram of study inclusion and exclusion. DL = deep learning; T = Tesla.
Table 1.
Patients’ characteristic.
| Patients (male/female), n | 30 (15/15) |
| Scanner (1.5 T/3 T), n | 15/15 |
| Age, mean ± SD (range), y | total: 50 ± 15 (22−76) |
| male: 55 ± 15 (33−76) | |
| female: 45 ± 15 (22 – 65) | |
| Shoulder (right/left), n | 15/15 |
| Indication of MRI, n | Impingement syndrome/calcific tendinitis, 11 |
| Rotator cuff tendinopathy/tear, 9 | |
| Acute trauma, 4 | |
| Instability or dislocation, 3 | |
| Pain not otherwise specified, 3 |
n indicates number; T, Tesla; SD, standard deviation; y, years.
2.2. MRI protocol
All MRI examinations were performed in routine clinical practice using 1.5 and 3 T MRI scanners (MAGNETOM Avantofit, MAGNETOM Aera, MAGNETOM Skyra, MAGNETOM Prismafit, and MAGNETOM Vida, Siemens Healthcare, Erlangen, Germany). Patients were examined in supine position with the arms in anatomical position using a 16-channel shoulder coil. All participants were examined with the institution´s standard protocol (TSES) and the accelerated protocol with DL-reconstruction (TSEDL). The TSES consisted of the following sequences: proton density (PD)-weighted TSE with fat saturation (FS) in three planes (axial, coronal, sagittal) as well as one coronal T1-weighted (T1w) TSE. Immediately after TSES, the same sequence protocol was acquired with undersampled TSE sequences and reconstructed on the scanner using the research DL-reconstruction (TSEDL). The detailed MRI acquisition parameters are listed in Table 2. Siemens Healthineers, Erlangen, Germany provided the research DL-reconstruction. Full control of patient data was with the authors.
Table 2.
Acquisition parameters.
| Parameters | ||||||||
|---|---|---|---|---|---|---|---|---|
| Acquisition parameters of TSES and TSEDL at 1.5 T | ||||||||
| PD TSES FS | PD TSEDLFS | PD TSES FS | PD TSEDLFS | T1 TSES | T1 TSEDL | PD TSES FS | PD TSEDLFS | |
| Orientation | axial | axial | coronal | coronal | coronal | coronal | sagittal | sagittal |
| TA, min:s | 2:56 | 1:05 | 2:53 | 1:02 | 1:44 | 1:11 | 2:53 | 1:02 |
| TE//TR, ms | 42/3800 | 51/3550 | 42/3290 | 42/3160 | 9.2/562 | 9.2/549 | 42/3290 | 42/3000 |
| FOV, mm2 | 180 | 180 | 180 | 180 | 180 | 180 | 180 | 180 |
| Voxel size, mm3 | 0.6×0.6×3.0 | 0.6×0.6×3.0 | 0.6×0.6×3.0 | 0.6×0.6×3.0 | 0.3×0.3×3.0 | 0.6×0.6×3.0 | 0.6×0.6×3.0 | 0.6×0.6×3.0 |
| FA, degree | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 |
| Averages | 2 | 1 | 2 | 1 | 1 | 1 | 2 | 1 |
| PAT | 2 | 3 | 2 | 3 | 2 | 3 | 2 | 3 |
| Turbo factor | 9 | 9 | 9 | 10 | 3 | 3 | 9 | 9 |
| Echo spacing, ms | 8.46 | 8.46 | 8.46 | 8.46 | 9.22 | 9.22 | 8.46 | 8.46 |
| Bandwith, Hz/Px | 191 | 191 | 191 | 191 | 211 | 211 | 191 | 191 |
| Acquisition parameters of TSES and TSEDL at 3 T | ||||||||
| PDS TSE FS | PD TSEDLFS | PD TSES FS | PD TSEDLFS | T1 TSES | T1 TSEDL | PD TSES FS | PD TSEDLFS | |
| Orientation | axial | axial | coronal | coronal | coronal | coronal | sagittal | sagittal |
| TA, min:s | 3:02 | 0:56 | 2:56 | 1:38 | 2:09 | 1:10 | 2:50 | 1:32 |
| TE//TR, ms | 40/3000 | 39/3400 | 38/3000 | 37/3000 | 11/523 | 11/531 | 51/3000 | 49/3000 |
| FOV, mm2 | 200 | 200 | 200 | 200 | 160 | 160 | 160 | 160 |
| Voxel size, mm3 | 0.5×0.5×3.0 | 0.5×0.5×3.0 | 0.4×0.4×3.0 | 0.4×0.4×3.0 | 0.4×0.4×3.0 | 0.4×0.4×3.0 | 0.4×0.4×3.0 | 0.4×0.4×3.0 |
| FA, degree | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 |
| Averages | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 0 |
| PAT | 2 | 4 | 2 | 4 | 2 | 4 | 2 | 4 |
| Turbo factor | 9 | 9 | 11 | 11 | 4 | 4 | 11 | 12 |
| Echo spacing, ms | 9.98 | 7.75 | 12.6 | 12.4 | 11 | 11.1 | 12.6 | 12.1 |
| Bandwith, Hz/Px | 250 | 250 | 150 | 150 | 250 | 250 | 150 | 150 |
TSE indicates turbo spin echo; T. Tesla; PD, proton density; DL, deep learning; FS, fat saturation; TA, acquisition time; FOV, field of view; TE/TR, echo time/repetition time; FOV, field of view; FA, flip angle; PAT, Parallel Acquisition Technique; Hz: Hertz; Px: Pixel.
2.3. Deep learning-reconstruction technique for TSE
The undersampling pattern and the DL-reconstruction used for the fast 5-minute TSEDL protocol in this study have been introduced in previous studies for TSE sequences [8], [11], [13], [15], [16], [17], [18]. The k-space data are prospectively undersampled according to established patterns as known from parallel imaging [19], [20] and reconstructed using a DL-based image reconstruction with a fixed iterative reconstruction scheme or variational network [19], [21].
The reconstruction was trained on previous volunteer acquisitions using conventional TSE protocols. Approximately 10,000 slices were acquired on volunteers using different clinical 1.5 T and 3 T scanners (MAGNETOM scanners, Siemens Healthcare, Erlangen, Germany).
For use in the clinical setting, the trained network was converted to a proprietary C++ inference framework and integrated into the reconstruction pipeline of the scanners.
2.4. Image analysis
The thirty pairs of corresponding TSES and TSEDL datasets were separated, anonymized, and randomized. Sixty individual studies were obtained. Each of these studies was independently assessed by two radiologists with 5 and 2 years of experience in musculoskeletal MRI interpretation. Readers were blinded to reconstruction type, clinical and radiological report, and each other’s assessment. Before evaluation, both readers completed a joint training session with ten complete examinations that were not included in this study. Image quality parameters were evaluated using the following criteria on a five-point Likert scale (5, excellent; 1, non-diagnostic): Overall image quality, artifacts, banding artifacts, edge sharpness, noise, and diagnostic confidence as well as image impression. Delineation of anatomic structures of the shoulder included rotator cuff tendons, long biceps tendon, glenoid labrum, glenohumeral joint, acromioclavicular joint, as well as lesser and greater tuberosity. The extent of delineation was rated using an ordinal five-point Likert scale (5, excellent delineation; 1, no delineation). Diagnostic performance was assessed by evaluating abnormalities of the rotator cuff tendons (supraspinatus, infraspinatus, subscapularis), long biceps tendon, and glenoid labrum for the presence of lesions using a three-point scale (0, normal; 1, degeneration; 2, tear). The acromioclavicular joint, the glenohumeral joint as well as the lesser and greater tuberosity were evaluated for the presence of lesions using a two-point scale (0, normal; 1, edema and/or subchondral cyst). Joint fluid and bone marrow edema were evaluated to be present or absent (0, absent; 1, present).
Image analysis was performed on a PACS workstation (GE Healthcare Centricity PACS RA1000, Milwaukee, WI, USA). Interpretation of the examinations for each subject was separated by a period of 6 weeks, and the readers were blinded to the other readers’ evaluations to limit the potential for recall bias.
2.5. Statistical evaluation
Statistical evaluation was performed using SPSS Statistics Version 26 (IMB, Armonk, NY; USA), Stata Version 16 (StataCorp, Texas, USA), and R (v4.0.3, R Core Team, Vienna, Austria). Whereas parametric variables are displayed using mean ± standard deviation (SD), non-parametric variables are displayed using mean, median and interquartile range (IQR) in parentheses. The Wilcoxon signed-rank test was used for paired data of ordinal structure and non-normally-distributed parametric variables. The significance level was set at 0.05.
Kappa statistic is commonly used to assess interreader reliability because it accounts for chance agreements [22]. We used the weighted Kappa-statistic to test the agreement between TSES and TSEDL, and both readers. We used the commonly accepted rules of thumb to interpret agreement as minimal to non-agreement if Kappa is smaller than 0.4, weak if Kappa is 0.4–0.59, moderate if Kappa is 0.6–0.79, and strong if Kappa > 0.8 [22].
2.6. Interchangeability analysis
In addition to agreement, we assessed interchangeability between the TSES and TSEDL [7], [23], [24], [25]. First the interreader agreement when both readers used the TSEDL (intra-protocol interreader agreement rate) was compared with the agreement when one reader used the TSEDL, and the other used the TSES (interprotocol interreader agreement rate). The interprotocol (TSES vs. TSEDL) interreader agreement rate was subtracted from the intraprotocol (TSES vs. TSES) interreader agreement rate, resulting in the individual equivalence index. A 95% confidence interval (95% CI) was calculated using bootstrapping methods with 10,000 repetitions, i.e., by repeating the calculation of the equivalence index 10,000 times based on a set of patients randomly sampled with replacement. The interreader agreement index and 95% CI were calculated for each individual score as well as for groupings. A smaller than 5% difference in rate of agreement was considered acceptable.
3. Results
3.1. Patients’ characteristics
Thirty patients with shoulder pain (15 men, 15 women; mean patient age: 50 ± 15 years, range: 22 – 76 years) were consecutively recruited. Scans were performed on patients’ symptomatic side (right: 15, left: 15), (see Table 1). An image example of the institution’s standard protocol with TSES and TSEDL is displayed in Fig. 2.
Fig. 2.
Example of a standard (TSES, upper row) and accelerated, deep learning reconstructed (TSEDL, lower row) shoulder MRI protocol with PD-weighted TSE sequences in axial (A), coronal (B), and sagittal oblique (C) orientation, as well as T1-weighted TSE in coronal orientation (D) of a 37-year-old patient with shoulder pain after trauma at 1.5 Tesla.
The results of the more experienced reader 2 are described in the following. All results can be found in the tables of this manuscript.
3.2. Qualitative image analysis
Intraprotocol interreader agreement regarding image quality parameters resulted in a Cohen´s kappa of 0.788 for TSES and 0.813 for TSEDL. Overall image quality was evaluated to be significantly superior in TSEDL compared to TSES with a median of 5 (IQR 5 – 5) versus a median of 4 (IQR 4 – 5; p<0.001). Image noise levels were evaluated to be significantly superior in TSEDL compared to TSES with a median of 5 (IQR 5 – 5) for TSEDL versus a median of 4 (IQR 4 – 5; p<0.001) for TSES. Edge sharpness was evaluated to be significantly superior in TSEDL compared to TSES with a median of 5 (IQR 5 – 5) for TSEDL versus a median of 4 (IQR 4 – 5; p=0.02) for TSES. No significant difference was found concerning the overall extent of artifacts in TSEDL and TSES with a median of 5 (IQR 4 – 5; p=0.16). The extent of banding artifacts was rated higher in TSEDL with a median of 5 (IQR 4 – 5) versus a median of 5 (IQR 5 – 5) in TSES (p<0.05). Diagnostic confidence was evaluated to be comparable in TSEDL compared to TSES with a median of 5 (5 – 5, p=0.18). There was no significant difference regarding the image impression of both sequences with a median of 5 (5 – 5) for TSES and with a median of 5 (4.75 – 5) for TSEDL (p=0.56). Concerning the delineation of anatomical structures, no significant difference was found between the two sequences TSES and TSEDL (p=0.16–0.66). Table 3 shows image quality results of both readers.
Table 3.
Image quality, lesion detectability, and interreader agreement using Cohen’s Kappa for TSES/TSEDL.
|
Reader 1 |
Reader 2 |
Intraprotocol interreader agreement |
||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| TSES Mean, Median (IQR) | TSEDL Mean, Median (IQR) | p-value | TSES Mean, Median (IQR) | TSEDL Mean, Median (IQR) |
p-value | TSES |
TSEDL |
|||
| Cohens κ | 95% CI | Cohens κ | 95% CI | |||||||
| Overall image quality | ||||||||||
| Image quality | 4.27, 4 (4−5) | 4.80, 5 (5−5) | <0.001 | 4.37, 4 (4−5) | 4.83, 5 (5−5) | <0.001 | 0.834 | [0.68;0.98] | 0.89 | [0.72;1.00] |
| Artifacts | 4.50, 5 (4−5) | 4.67, 5 (4−5) | 0.10 | 4.57, 5 (4−5) | 4.70, 5 (4−5) | 0.16 | 0.789 | [0.61;0.95] | 0.93 | [0.81;1.00] |
| Banding artifacts | 4.93, 5 (5−5) | 4.60, 5 (4−5) | 0.004 | 4.90, 5 (5−5) | 4.63, 5 (4−5) | 0.02 | 0.783 | [0.37;1.00] | 0.82 | [0.63;1.00] |
| Edge sharpness | 4.47, 4 (4−5) | 4.87, 5 (5−5) | <0.001 | 4.57, 5 (4−5) | 4.80, 5 (5−5) | 0.02 | 0.802 | [0.59;0.96] | 0.76 | [0.45;1.00] |
| Noise | 4.37, 4 (4−5) | 4.90, 5 (5−5) | <0.001 | 4.40, 4 (4−5) | 4.83, 5 (5−5) | <0.001 | 0.935 | [0.82;1.00] | 0.71 | [0.35;1.00] |
| Diagnostic confidence | 4.77, 5 (4.75–5) | 4.87, 5 (5−5) | 0.08 | 4.80, 5 (5−5) | 4.90, 5 (5−5) | 0.18 | 0.706 | [0.40;1.00] | 0.84 | [0.53;1.00] |
| Image impression | 4.83, 5 (5−5) | 4.73, 5 (4−5) | 0.08 | 4.80, 5 (5−5) | 4.77, 5 (4.75–5) | 0.56 | 0.667 | [0.32;1.00] | 0.73 | [0.45;1.00] |
| Delineation of anatomic structures | ||||||||||
| Rotator cuff tendons | 4.80, 5 (5−5) | 4.77, 5 (4.75–5) | 0.32 | 4.73, 5 (4−5) | 4.77, 5 (4.75–5) | 0.32 | 0.815 | [0.57;1.00] | 0.81 | [0.57;1.00] |
| Long biceps tendon | 4.77, 5 (5−5) | 4.83, 5 (5−5) | 0.32 | 4.73, 5 (4.75–5) | 4.77, 5 (4.75–5) | 0.66 | 0.918 | [0.76;1.00] | 0.79 | [0.52;1.00] |
| Glenoid labrum | 4.70, 5 (4−5) | 4.80, 5 (5−5) | 0.08 | 4.60, 5 (4−5) | 4.67, 5 (4−5) | 0.16 | 0.783 | [0.56;1.00] | 0.67 | [0.38;1.00] |
| Acromioclavicular joint | 4.83, 5 (5−5) | 4.80, 5 (5−5) | 0.32 | 4.83, 5 (5−5) | 4.80, 5 (5−5) | 0.66 | 0.760 | [0.44;1.00] | 0.67 | [0.32;1.00] |
| Glenohumeral joint | 4.83, 5 (5−5) | 4.90, 5 (5−5) | 0.16 | 4.73, 4 (5−5) | 4.80, 5 (5−5) | 0.16 | 0.710 | [0.41;1.00] | 0.62 | [0.23;1.00] |
| Lesser tuberosity | 4.83, 5 (5−5) | 4.77, 5 (4.75–5) | 0.41 | 4.73, 4 (5−5) | 4.80, 5 (5−5) | 0.41 | 0.710 | [0.44;1.00] | 0.71 | [0.40;1.00] |
| Greater tuberosity | 4.80, 5 (5−5) | 4.83, 5 (5−5) | 0.56 | 4.77, 4.75 (5−5) | 4.80, 5 (5−5) | 0.56 | 0.902 | [0.71;1.00] | 0.67 | [0.32;1.00] |
IQR indicates interquartile range; TSE, turbo spin echo; S, standard; DL, deep learning.
Image quality grading: 1 = non-diagnostic, 2 = low image quality, non-diagnostic; 3 = minor image quality impairment, diagnostic; 4= good image quality, diagnostic; 5 = excellent image quality, diagnostic)
Cohen’s κ, interreader-agreement (0–0.20 = poor agreement, 0.21–0.40 = fair agreement, 0.41–0.60 = moderate agreement, 0.61–0.80 = substantial agreement, 0.81–1 = (almost) perfect agreement)
3.3. Interchangeability analysis
While interreader agreement ranged from 83.33 – 96.67% for different structures, intrareader agreement between TSEDL and TSES was nearly identical with 80.00 – 93.33% for almost all of the evaluated structures. The CIs for all evaluated parameters were within the critical limit [-5%, +5%], indicating that TSEDL and TSES are interchangeable (Table 4).
Table 4.
Interprotocol intrareader agreement and interchangeability results concerning shoulder lesions using Cohen’s Kappa for TSES/TSEDL.
|
Interprotocol intrareader agreement |
Interchangeability results |
|||||||
|---|---|---|---|---|---|---|---|---|
| R1 |
R2 |
R1 vs R2 | TSES vs TSEDL | |||||
| Cohens κ | 95% CI | Cohens κ | 95% CI | Agreement | Agreement | Index | 95% CI | |
| Supraspinatus tendon | 0.85 | [0.73;0.97] | 0.94 | [0.86;1.02] | 83.33% | 80.00% | 3.33% | [-15.00;21.65] |
| Infraspinatus tendon | 0.83 | [0.59;1.07] | 0.92 | [0.76;1.08] | 93.33% | 90.00% | -3.33% | [-14.32;0.81] |
| Subscapularis tendon | 0.81 | [0.54;1.09] | 0.81 | [0.54;1.09] | 90.00% | 90.00% | <0.01% | [-17.04;16.90] |
| Long biceps tendon | 0.72 | [0.46;0.99] | 0.89 | [0.73;1.05] | 90.00% | 90.00% | <0.01% | [-15.33;15.43] |
| Glenoid labrum | 0.76 | [0.45;1.07] | 0.76 | [0.45;1.07] | 90.00% | 88.33% | -1.67% | [-15.61;18.71] |
| Acromioclavicular joint | 0.83 | [0.61;1.05] | 0.91 | [0.74;1.08] | 90.00% | 88.33% | 1.67% | [-15.01;18.04] |
| Glenohumeral joint | 0.79 | [0.52;1.06] | 0.79 | [0.52;1.06] | 93.33% | 91.67% | -1.67% | [-16.25;19.11] |
| Lesser tuberosity | 0.63 | [0.18;1.09] | 0.63 | [0.18;1.09] | 96.67% | 93.33% | 3.33% | [-18.47;24.57] |
| Greater tuberosity | 0.86 | [0.67;1.05] | 0.86 | [0.67;1.05] | 93.33% | 88.33% | 5.00% | [-13.07;23.12] |
| Joint fluid | 0.87 | [0.69;1.05] | 0.87 | [0.69;1.05] | 90.00% | 90.00% | <0.01% | [-15.33;15.43] |
| Bone marrow edema | 0.92 | [0.78;1.07] | 0.92 | [0.78;1.07] | 93.33% | 93.33% | <0.01% | [-15.27;15.45] |
TSE indicates turbo spin echo; S, standard; DL, deep learning; CI, confidence interval.
Cohen’s κ, (0–0.20 = poor agreement, 0.21–0.40 = fair agreement, 0.41–0.60 = moderate agreement, 0.61–0.80 = substantial agreement, 0.81–1 = (almost) perfect agreement)
Table 4 shows detailed interprotocol intrareader agreement and interchangeability results with corresponding confidence intervals. Fig. 2, Fig. 3, Fig. 4, Fig. 5 show examples of TSES and TSEDL.
Fig. 3.
Example of a standard (TSES, upper row) and accelerated, deep learning reconstructed (TSEDL, lower row) shoulder MRI of the right shoulder at 3 Tesla of a 59-year-old female patient with pain and impingement symptoms. PD-weighted TSE sequences are displayed in axial (A), coronal (B), and sagittal oblique (C) orientation, as well as T1-weighted TSE in coronal orientation (D). In both, TSES and TSEDL a structure hypointense in PD- and T1-weighted TSE is seen in the cranial portion of the infraspinatus tendon measuring approximately 9 ×20 mm. Comparing TSES and TSEDL noise is significantly reduced in TSEDL and findings as the calcified structure can be very well delineated in both sequences, with the TSEDL providing improved edge sharpness.
Fig. 4.
Example of a standard (TSES, upper row) and accelerated, deep learning reconstructed (TSEDL, lower row) shoulder MRI of the right shoulder at 3 Tesla of a 76-year-old patient with omalgia on the right side and suspected rotator cuff lesion at 3 Tesla. In the coronal PD-weighted TSE (A) you find a complete transmural rupture of the supraspinatus tendon (arrow) which is well delineated in both sequences, but slightly sharper in the TSEDL. In the axial PD-weighted TSE (B) the attachment tendinopathy of the subscapularis tendon (arrow head) is better delineated in the TSEDL due to fewer motion artifacts, which in turn is attributed to the shorter acquisition time. The rupture of the infraspinatus muscle with tendon retraction in the PD-weighted TSE in sagittal oblique orientation (C) can be very well delineated in both sequences, with the TSEDL providing improved sharpness and less noise.
Fig. 5.
Example of a standard (TSES, upper row) and accelerated, deep learning reconstructed (TSEDL, lower row) shoulder MRI examination of a 58-year-old patient with shoulder pain and suspected rotator cuff rupture at 1.5 Tesla with PD-weighted TSE sequences in coronal (A), sagittal oblique (B), and axial (C) orientation. Rupture of the supraspinatus tendon with slight retraction (arrow) is seen, which is well delineated in both sequences, but slightly sharper in the TSEDL. Noise is reduced in TSEDL compared to TSES.
3.4. Acquisition time reduction
The acquisition time (TA) of the fast TSEDL protocol was 4:21 min versus 10:26 min of TSES protocol for 1.5 T and 5:16 min versus 10:56 min of TSES protocol for 3 T. Thus, TA for a native shoulder MRI protocol using TSEDL was reduced by 58% for 1.5 T and by 52% for 3 T compared to the standard TSES protocol. These scan times were selected from the standard examination without adjusting the parameters for each individual.
4. Discussion
This study investigated the feasibility and compared the image quality and diagnostic performance of a fast 5-minute 2D TSE imaging with DL-reconstruction of the shoulder at 1.5 and 3 T and demonstrated that TSEDL imaging of the shoulder was feasible in daily clinical routine, with acquisition time reduced by more than 50% and improved image quality compared to TSES.
In recent years, various imaging techniques have been developed and investigated to shorten the acquisition time of musculoskeletal MRI. A long acquisition time may compromise image quality due to motion artifacts caused by patient discomfort due to prolonged immobility. Mainly isotropic 3D sequences using gradient-echo or TSE techniques have been developed and implemented, which allow high-quality multiplanar reformat images in thin continuous slices to provide a good delineation of anatomical structures. To further accelerate the 3D acquisition, Lee et al. investigated the application of compressed sensing (CS) to a 3D-TSE sequence for shoulder MRI [6]. CS is an established method for accelerating MRI acquisitions, including 2D sequences, and is based on redundancy of imaging data. The main disadvantages of CS images are their unnatural appearance and the long computation processing time [26]. Although Lee et al. found no relevant compromise in image quality comparing 3D-TSE with CS to standard 3D-TSE, no significant difference was found in terms of motions artifacts, and acquisition time was reduced only by about 30%. In our study, apart from no significant difference in terms of artifact extent, acquisition time was reduced by over 50% compared to standard imaging.
The potential of the DL-reconstruction in musculoskeletal MRI has previously been demonstrated in several studies [8], [9], [11], [13], [14], [18], including Hahn et al. who first showed the applicability of this technique in shoulder MRI, providing a 67% scan time reduction with comparable image quality, artifacts, and diagnostic performance in a cohort of 105 participants when using a PI undersampling pattern with an acceleration factor of 4 and the DL-reconstruction [10]. Obama et al. compared the DL-reconstruction in their study when using a CS and a PI undersampling pattern, including 30 participants and showed an improved image quality when using the DL-reconstruction, and a significantly shorter scan time, when combining the CS undersampling with the DL-reconstruction compared to the PI undersampling pattern with the DL-reconstruction [12]. However, in the aforementioned studies, the authors used exclusively MR scanners of 3 T and, beyond that, Obama et al. did not include the detectability of pathologies in the evaluation and assessed image quality solely.
In our study, we applied the DL-reconstruction in daily clinical routine at 1.5 and 3 T using an PI-based method with high undersampling factors was used to accelerate the image acquisition. In our study, image quality could be improved and no difference was found in the delineation of anatomical structures and the detection of various pathologies, which is in line with the aforementioned studies. Furthermore, in our study, no difference in the extent of artifacts was observed. Moreover, image quality was actually improved when DL-reconstruction was used. A major disadvantage of PI is the loss of SNR with the increase in acceleration factor. This is accompanied by banding artifacts, a disadvantage of DL-reconstructed images in our study. Banding artifacts are characteristic artifacts that appear in the form of a stripe pattern aligned exactly with the phase-encoding direction and are particularly strong in the low-SNR regions of DL-reconstructed images [27]. Although one reader noted a significantly higher extent of banding artifacts in the images of the TSEDL protocol compared to TSES, overall image quality and general extent of artifacts as well as the diagnostic confidence of the images were not affected. Therefore, it can be assumed that the appearance of banding artifacts does not affect the image quality and the detection of pathological findings. Moreover, recent approaches have shown promising results in reducing such banding artifacts [27].
Despite the reduction in acquisition time and improved image quality, the question arises as to what clinical benefit can be derived from these results. MRI of the shoulder is an important tool for diagnosing the most common causes of shoulder pain, such as impingement syndrome or rotator cuff tears, and plays an important role in therapy planning [1], [2], [28], [29]. However, increasing demand for examinations does not automatically lead to an increase in supply because of limited availability of MRI scanners and examination times. To our knowledge, our study is the first to evaluate the implementation of DL-reconstruction on undersampled sequences for the shoulder in a prospective setting in daily clinical practice at both 1.5 and 3 T. DL-reconstruction could be implemented in the clinical workflow, and during reconstruction, the MR-scanner could acquire subsequent sequences without interfering with the ongoing scanning workflow. In addition, the demonstrated approach of acquisition time reduction of more than 50% for multiplane, multicontrast imaging of the shoulder offers tremendous potential to increase scanner availability. Furthermore, reduced acquisition time proves to be an important advantage concerning patient comfort when examining patients who are sensitive to closed spaces, particularly among children.
Nonetheless, our study was not without limitations. First, although our 5-minute TSEDL-protocol was comparable with TSES for all structures evaluated, the small sample size and the low prevalence of abnormalities, such as rotator cuff tears may limit the generalizability of the findings. Second, solely DL-reconstructions of T1- and PD-weighted 2D TSE imaging were examined in this study. However, due to the time-consuming acquisition process of PD-weighted sequences, these sequences were preferred for implementation. Third, although no significant difference in image impression was found between TSEDL and TSES, readers were likely able to identify whether they were interpreting TSEDL or TSES because of the characteristic appearance of the DL-reconstructed images. However, recall bias was minimized by randomization of datasets and a washout period of 30 days, before readers evaluated the second set of images of each patient.
In conclusion, a novel 5-minute TSEDL protocol for the shoulder is feasible in daily clinical routine at 1.5 and 3 T and allows for a reduction in acquisition time of more than 50%, while improving image quality and maintaining equivalent diagnostic performance of shoulder abnormalities compared to standard TSE imaging. Therefore, TSEDL may pave the way for the introduction of ultrafast protocols in shoulder MRI.
Funding
This research received no external funding.
Ethical statement
This prospective study was approved by the institutional review board (University of Tuebingen, clinical trial registry number: DRKS00023278) and written informed consent was obtained from all participants. All study procedures were in accordance with the Declaration of Helsinki and its subsequent amendments.
CRediT authorship contribution statement
You-Shan Feng: Writing – review & editing, Validation, Methodology, Investigation. Judith Herrmann: Writing – original draft, Visualization, Validation, Resources, Project administration, Methodology, Investigation, Formal analysis, Data curation, Conceptualization. Andreas Lingg: Writing – review & editing, Supervision, Methodology, Data curation, Conceptualization. Gregor Koerzdoerfer: Writing – review & editing, Software. Jan-Peter Grunz: Writing – review & editing, Validation, Supervision. Sebastian Gassenmaier: Writing – review & editing, Validation, Supervision, Project administration, Methodology, Investigation, Formal analysis, Data curation, Conceptualization. Saif Afat: Writing – review & editing, Visualization, Validation, Supervision, Resources, Project administration, Methodology, Investigation, Formal analysis, Data curation, Conceptualization. Ahmed E. Othman: Writing – review & editing, Validation, Supervision, Project administration, Formal analysis, Data curation, Conceptualization. Dominik Nickel: Writing – review & editing, Software. Haidara Al-Mansour: Writing – review & editing, Investigation, Formal analysis, Data curation.
Declaration of Competing Interest
The authors declare the following financial interests/personal relationships which may be considered as potential competing interests. Gregor Koerzdoerfer and Dominik Nickel are employees of Siemens Healthineers, Germany and provided the prototype Deep Learning reconstruction used in this study. Full control of patient data was with the authors of University of Tuebingen and who are not employees of Siemens
References
- 1.Pappou I.P., Schmidt C.C., Jarrett C.D., Steen B.M., Frankle M.A. AAOS appropriate use criteria: optimizing the management of full-thickness rotator cuff tears. J. Am. Acad. Orthop. Surg. 2013;21(12):772–775. doi: 10.5435/JAAOS-21-12-772. [DOI] [PubMed] [Google Scholar]
- 2.Lenza M., Buchbinder R., Takwoingi Y., Johnston R.V., Hanchard N.C., Faloppa F. Magnetic resonance imaging, magnetic resonance arthrography and ultrasonography for assessing rotator cuff tears in people with shoulder pain for whom surgery is being considered. Cochrane Database Syst. Rev. 2013;(9):CD009020. doi: 10.1002/14651858.CD009020.pub2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Daniels S.P., Gyftopoulos S. 3D MRI of the Shoulder. Semin. Musculoskelet. Radiol. 2021;25(3):480–487. doi: 10.1055/s-0041-1728813. [DOI] [PubMed] [Google Scholar]
- 4.Hou B., Li Y., Xiong Y., Morelli J.N., Wang J., Liu C., Wu G., Li X. Comparison of CAIPIRINHA-accelerated 3D fat-saturated-SPACE MRI with 2D MRI sequences for the assessment of shoulder pathology. Eur. Radiol. 2022;32(1):593–601. doi: 10.1007/s00330-021-08183-3. [DOI] [PubMed] [Google Scholar]
- 5.Kloth J.K., Winterstein M., Akbar M., Meyer E., Paul D., Kauczor H.U., Weber M.A. Comparison of 3D turbo spin-echo SPACE sequences with conventional 2D MRI sequences to assess the shoulder joint. Eur. J. Radiol. 2014;83(10):1843–1849. doi: 10.1016/j.ejrad.2014.06.011. [DOI] [PubMed] [Google Scholar]
- 6.Lee S.H., Lee Y.H., Song H.T., Suh J.S. Rapid acquisition of magnetic resonance imaging of the shoulder using three-dimensional fast spin echo sequence with compressed sensing. Magn. Reson Imaging. 2017;42:152–157. doi: 10.1016/j.mri.2017.07.022. [DOI] [PubMed] [Google Scholar]
- 7.Subhas N., Benedick A., Obuchowski N.A., Polster J.M., Beltran L.S., Schils J., Ciavarra G.A., Gyftopoulos S. Comparison of a fast 5-minute shoulder MRI protocol with a standard shoulder MRI protocol: a multiinstitutional multireader study. AJR Am. J. Roentgenol. 2017;208(4):W146–W154. doi: 10.2214/AJR.16.17041. [DOI] [PubMed] [Google Scholar]
- 8.Herrmann J., Koerzdoerfer G., Nickel D., Mostapha M., Nadar M., Gassenmaier S., Kuestner T., Othman A.E. Feasibility and Implementation of a deep learning MR reconstruction for TSE sequences in musculoskeletal imaging. Diagnostics. 2021;11(8) doi: 10.3390/diagnostics11081484. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Recht M.P., Zbontar J., Sodickson D.K., Knoll F., Yakubova N., Sriram A., Murrell T., Defazio A., Rabbat M., Rybak L., Kline M., Ciavarra G., Alaia E.F., Samim M., Walter W.R., Lin D., Lui Y.W., Muckley M., Huang Z., Johnson P., Stern R., Zitnick C.L. Using deep learning to accelerate knee MRI at 3T: results of an Interchangeability Study. AJR Am. J. Roentgenol. 2020 doi: 10.2214/AJR.20.23313. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Hahn S., Yi J., Lee H.J., Lee Y., Lim Y.J., Bang J.Y., Kim H., Lee J. Image Quality and diagnostic performance of accelerated shoulder MRI with deep learning-based reconstruction. AJR Am. J. Roentgenol. 2022;218(3):506–516. doi: 10.2214/AJR.21.26577. [DOI] [PubMed] [Google Scholar]
- 11.Herrmann J., Keller G., Gassenmaier S., Nickel D., Koerzdoerfer G., Mostapha M., Almansour H., Afat S., Othman A.E. Feasibility of an accelerated 2D-multi-contrast knee MRI protocol using deep-learning image reconstruction: a prospective intraindividual comparison with a standard MRI protocol. Eur. Radiol. 2022 doi: 10.1007/s00330-022-08753-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Obama Y., Ohno Y., Yamamoto K., Ikedo M., Yui M., Hanamatsu S., Ueda T., Ikeda H., Murayama K., Toyama H. MR imaging for shoulder diseases: Effect of compressed sensing and deep learning reconstruction on examination time and imaging quality compared with that of parallel imaging. Magn. Reson Imaging. 2022;94:56–63. doi: 10.1016/j.mri.2022.08.004. [DOI] [PubMed] [Google Scholar]
- 13.Almansour H., Herrmann J., Gassenmaier S., Afat S., Jacoby J., Koerzdoerfer G., Nickel D., Mostapha M., Nadar M., Othman A.E. Deep learning reconstruction for accelerated spine MRI: prospective analysis of interchangeability. Radiology. 2022 doi: 10.1148/radiol.212922. [DOI] [PubMed] [Google Scholar]
- 14.Koch K.M., Sherafati M., Arpinar V.E., Bhave S., Ausman R., Nencka A.S., Lebel R.M., McKinnon G., Kaushik S.S., Vierck D., Stetz M.R., Fernando S., Mannem R. Analysis and evaluation of a deep learning reconstruction approach with denoising for orthopedic MRI. Radiol. Artif. Intell. 2021;3(6) doi: 10.1148/ryai.2021200278. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Gassenmaier S., Afat S., Nickel D., Mostapha M., Herrmann J., Othman A.E. Deep learning-accelerated T2-weighted imaging of the prostate: reduction of acquisition time and improvement of image quality. Eur. J. Radiol. 2021;137 doi: 10.1016/j.ejrad.2021.109600. [DOI] [PubMed] [Google Scholar]
- 16.Gassenmaier S., Afat S., Nickel M.D., Mostapha M., Herrmann J., Almansour H., Nikolaou K., Othman A.E. Accelerated T2-weighted TSE imaging of the prostate using deep learning image reconstruction: a prospective comparison with standard T2-weighted TSE imaging. Cancers. 2021;13(14) doi: 10.3390/cancers13143593. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Gassenmaier S., Afat S., Nickel D., Mostapha M., Herrmann J., Othman A.E. Deep learning–accelerated T2-weighted imaging of the prostate: reduction of acquisition time and improvement of image quality. Eur. J. Radiol. 2021 doi: 10.1016/j.ejrad.2021.109600. [DOI] [PubMed] [Google Scholar]
- 18.Wessling D., Herrmann J., Afat S., Nickel D., Othman A.E., Almansour H., Gassenmaier S. Reduction in acquisition time and improvement in image quality in T2-weighted MR imaging of musculoskeletal tumors of the extremities using a novel deep learning-based reconstruction technique in a turbo spin echo (TSE) sequence. Tomography. 2022;8(4):1759–1769. doi: 10.3390/tomography8040148. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Hammernik K., Klatzer T., Kobler E., Recht M.P., Sodickson D.K., Pock T., Knoll F. Learning a variational network for reconstruction of accelerated MRI data. Magn. Reson. Med. 2018;79(6):3055–3071. doi: 10.1002/mrm.26977. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Knoll F., Hammernik K., Kobler E., Pock T., Recht M.P., Sodickson D.K. Assessment of the generalization of learned image reconstruction and the potential for transfer learning. Magn. Reson. Med. 2019;81(1):116–128. doi: 10.1002/mrm.27355. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Schlemper J., Caballero J., Hajnal J.V., Price A.N., Rueckert D. A deep cascade of convolutional neural networks for dynamic MR image reconstruction. IEEE Trans. Med. Imaging. 2018;37(2):491–503. doi: 10.1109/TMI.2017.2760978. [DOI] [PubMed] [Google Scholar]
- 22.McHugh M.L. Interrater reliability: the kappa statistic. Biochem. Med. 2012;22(3):276–282. [PMC free article] [PubMed] [Google Scholar]
- 23.Obuchowski N.A., Subhas N., Schoenhagen P. Testing for interchangeability of imaging tests. Acad. Radiol. 2014;21(11):1483–1489. doi: 10.1016/j.acra.2014.07.004. [DOI] [PubMed] [Google Scholar]
- 24.Alaia E.F., Benedick A., Obuchowski N.A., Polster J.M., Beltran L.S., Schils J., Garwood E., Burke C.J., Chang I.J., Gyftopoulos S., Subhas N. Comparison of a fast 5-min knee MRI protocol with a standard knee MRI protocol: a multi-institutional multi-reader study. Skelet. Radiol. 2018;47(1):107–116. doi: 10.1007/s00256-017-2780-9. [DOI] [PubMed] [Google Scholar]
- 25.Zanchi F., Richard R., Hussami M., Monier A., Knebel J.F., Omoumi P. MRI of non-specific low back pain and/or lumbar radiculopathy: do we need T1 when using a sagittal T2-weighted Dixon sequence? Eur. Radiol. 2020;30(5):2583–2593. doi: 10.1007/s00330-019-06626-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Feng L., Benkert T., Block K.T., Sodickson D.K., Otazo R., Chandarana H. Compressed sensing for body MRI. J. Magn. Resonl Imaging. 2017;45(4):966–987. doi: 10.1002/jmri.25547. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.A. Defazio, T. Murrell, M.P. Recht, MRI Banding Removal via Adversarial Training, arXiv preprint arXiv:2001.08699 (2020).
- 28.Smith T.O., Drew B.T., Toms A.P. A meta-analysis of the diagnostic test accuracy of MRA and MRI for the detection of glenoid labral injury. Arch. Orthop. Trauma Surg. 2012;132(7):905–919. doi: 10.1007/s00402-012-1493-8. [DOI] [PubMed] [Google Scholar]
- 29.Seeger L.L., Gold R.H., Bassett L.W., Ellman H. Shoulder impingement syndrome: MR findings in 53 shoulders. AJR Am. J. Roentgenol. 1988;150(2):343–347. doi: 10.2214/ajr.150.2.343. [DOI] [PubMed] [Google Scholar]





