Abstract
Background
Hyperpolarized gas MRI is a functional lung imaging modality capable of visualizing regional lung ventilation with exceptional detail within a single breath. However, this modality requires specialized equipment and exogenous contrast, which limits widespread clinical adoption. CT ventilation imaging employs various metrics to model regional ventilation from non‐contrast CT scans acquired at multiple inflation levels and has demonstrated moderate spatial correlation with hyperpolarized gas MRI. Recently, deep learning (DL)‐based methods, utilizing convolutional neural networks (CNNs), have been leveraged for image synthesis applications. Hybrid approaches integrating computational modeling and data‐driven methods have been utilized in cases where datasets are limited with the added benefit of maintaining physiological plausibility.
Purpose
To develop and evaluate a multi‐channel DL‐based method that combines modeling and data‐driven approaches to synthesize hyperpolarized gas MRI lung ventilation scans from multi‐inflation, non‐contrast CT and quantitatively compare these synthetic ventilation scans to conventional CT ventilation modeling.
Methods
In this study, we propose a hybrid DL configuration that integrates model‐ and data‐driven methods to synthesize hyperpolarized gas MRI lung ventilation scans from a combination of non‐contrast, multi‐inflation CT and CT ventilation modeling. We used a diverse dataset comprising paired inspiratory and expiratory CT and helium‐3 hyperpolarized gas MRI for 47 participants with a range of pulmonary pathologies. We performed six‐fold cross‐validation on the dataset and evaluated the spatial correlation between the synthetic ventilation and real hyperpolarized gas MRI scans; the proposed hybrid framework was compared to conventional CT ventilation modeling and other non‐hybrid DL configurations. Synthetic ventilation scans were evaluated using voxel‐wise evaluation metrics such as Spearman's correlation and mean square error (MSE), in addition to clinical biomarkers of lung function such as the ventilated lung percentage (VLP). Furthermore, regional localization of ventilated and defect lung regions was assessed via the Dice similarity coefficient (DSC).
Results
We showed that the proposed hybrid framework is capable of accurately replicating ventilation defects seen in the real hyperpolarized gas MRI scans, achieving a voxel‐wise Spearman's correlation of 0.57 ± 0.17 and an MSE of 0.017 ± 0.01. The hybrid framework significantly outperformed CT ventilation modeling alone and all other DL configurations using Spearman's correlation. The proposed framework was capable of generating clinically relevant metrics such as the VLP without manual intervention, resulting in a Bland‐Altman bias of 3.04%, significantly outperforming CT ventilation modeling. Relative to CT ventilation modeling, the hybrid framework yielded significantly more accurate delineations of ventilated and defect lung regions, achieving a DSC of 0.95 and 0.48 for ventilated and defect regions, respectively.
Conclusion
The ability to generate realistic synthetic ventilation scans from CT has implications for several clinical applications, including functional lung avoidance radiotherapy and treatment response mapping. CT is an integral part of almost every clinical lung imaging workflow and hence is readily available for most patients; therefore, synthetic ventilation from non‐contrast CT can provide patients with wider access to ventilation imaging worldwide.
Keywords: Functional lung imaging, CT ventilation, Hyperpolarized gas MRI, Deep learning, Image synthesis
1. INTRODUCTION
Lung diseases represent significant global health challenges. 1 , 2 Imaging of the lungs constitutes a key component of clinical care, providing both anatomical and functional information for a wide range of lung pathologies. Functional lung imaging modalities such as single‐photon emission computed tomography (SPECT), positron emission tomography (PET) and hyperpolarized gas magnetic resonance imaging (MRI) have shown efficacy in several applications such as early diagnosis, functional lung avoidance radiotherapy and treatment response evaluation. 3 , 4 , 5 Hyperpolarized gas MRI is a functional lung imaging modality capable of visualizing regional lung ventilation with exceptional detail within a single breath. 6 Quantitative biomarkers derived from this modality, including the ventilated lung percentage (VLP), provide further insights into regional ventilation. 7 However, this modality requires specialized equipment, including a laser polarizer, and inhaled contrast agents such as helium‐3 (3He) or xenon‐129 (129Xe) noble gases, which currently limits widespread clinical adoption. 8
Computed tomography (CT) is the most widely used anatomical imaging modality and is an integral part of clinical care for most patients with lung pathologies. CT ventilation imaging (CTVI) aims to model regional ventilation from non‐contrast CT scans acquired at multiple inflation levels, either during tidal breathing or breath‐hold. 9 , 10 CTVI assumes that changes in regional lung volume and/or lung density between inflation levels is representative of lung ventilation. 11 Several metrics have been proposed to generate synthetic ventilation maps from multi‐inflation CT, such as those that map changes in Hounsfield units (CTHU) or the determinant of the Jacobian (CTJAC). 9 , 10 The CTHU metric is based on differences in HU intensities between inflation levels whereas the CTJAC metric is a measure of volume expansion computed directly on the deformation vector field between inflations. Previous validation of CTVI methods included assessing Spearman's correlation with well‐established lung function measures, such as spirometry, resulting in moderate correlations, ranging from 0.38 to 0.73 for both the CTHU and CTJAC methods. 12 , 13 CTVI models have also been validated against nuclear imaging modalities, exhibiting moderate correlation with SPECT and PET imaging 14 , 15 ; however, these studies report highly variable results and often use small numbers of patients. 16 Furthermore, nuclear medicine imaging has a relatively poor spatial and temporal resolution and a susceptibility to aerosol deposition artifacts, particularly within defect regions. 17 , 18 In addition, the requirement of radioactive contrast agents makes nuclear medicine imaging unattainable for some patient groups, for example, pediatrics. By using hyperpolarized gas MRI for validation, Tahir et al. 19 showed moderate Spearman's correlations of several CTVI metrics.
Recently, deep learning (DL)‐based methods utilizing convolutional neural networks (CNNs) have become widespread in numerous lung imaging applications, including image synthesis. 20 Zhong et al. 21 used a CNN to synthesize CT‐based ventilation surrogates from 4DCT, reporting a mean square error (MSE) of 7.6%. However, a limitation of this approach is that CT ventilation images, used as the ground truth ventilation, are in themselves the subject of intense validation efforts. 22 Ren et al. 23 have shown the capability of deriving synthetic perfusion maps from CT using SPECT perfusion as ground truth; a 3D UNet CNN was used, achieving an average Spearman's correlation of 0.81 using three‐fold cross‐validation. A Dice similarity coefficient (DSC) value of 0.81 was achieved for both high‐functional and low‐functional lung regions. Furthermore, Liu et al. 24 proposed a CNN‐based approach to synthesize Technegas SPECT ventilation images from non‐contrast 4DCT. They demonstrated, after post‐processing, Spearman's correlations of 0.73 and 0.71 for 10‐phase and 2‐phase 4DCT, respectively. Ten‐fold cross‐validation was used, achieving an average DSC across all folds of 0.83 for high‐functional lung regions, 0.61 for medium‐functional lung regions, and 0.73 for low‐functional lung regions. Subsequently, Grover et al. 25 investigated the utility of CNNs for synthesizing Galligas PET ventilation images, demonstrating a mean Spearman's correlation of 0.58 and a mean DSC for high, medium, and low functional regions of 0.55. However, SPECT and PET have significantly longer acquisition times compared to CT imaging which facilitates acquisition within a single breath. This leads to the possibility of time‐delayed ventilation filling, 26 reducing the relationship between structural and functional imaging modalities. Conversely, hyperpolarized gas MRI ventilation has an acquisition time spanning a single breath, similar to that of CT, leading to a potentially more accurate representation of ventilation at a specific point in time. Capaldi et al. 27 has recently used a 2D UNet CNN to map free‐breathing proton MRI to 3He hyperpolarized gas MRI, achieving a Pearson correlation of 0.87 and a mean DSC of 0.90 and 0.37 for ventilated and defect lung regions, respectively. However, synthesizing hyperpolarized gas MRI directly from multi‐inflation CT has not yet been demonstrated.
Despite promising results achieved by DL synthesis techniques in multiple domains, there has been a lack of widespread adoption due to an inability to produce physiologically consistent results. Additionally, there is often a shortage of available data representative of a diverse population; to this end, several researchers have proposed the use of hybrid approaches that leverage computational modeling alongside data‐driven approaches, such as deep learning, 28 precluding the requirement for large datasets. For example, hybrid physics‐ and model‐based approaches have been used in weather forecasting, 29 earth surface modeling, 30 and spatiotemporal dynamic systems evolution in robotics. 31 Hybrid approaches have also been used for data generation in situations where there is limited data available. 32
We hypothesized that a hybrid framework that integrates physiological‐based multi‐inflation level CT ventilation modeling and CNN‐based DL may generate accurate surrogate ventilation maps. Accordingly, we propose a hybrid model‐ and DL‐based framework, where conventional CTHU models are used alongside structural inspiratory and expiratory CT scans as inputs to a CNN for functional lung image synthesis. In addition, we propose an automatic pipeline for predicting VLPs from the DL‐generated synthetic ventilation scans using CNN‐based segmentation. Due to the relatively small dataset, data‐driven approaches alone are unlikely to generate accurate synthetic ventilation images, especially in patients with significant ventilation defects. Therefore, the combination of data‐driven and physiological modeling approaches utilizes both methods’ benefits to produce physiologically consistent results, whilst also allowing features to be learnt from underlying patterns in the available data.
2. MATERIALS AND METHODS
2.1. Dataset
The dataset comprised paired inspiratory and expiratory CT and hyperpolarized 3He MRI scans for 47 patients originating from three clinical observational studies that were approved by the National Research Ethics Committee (REC). Lung cancer (n = 16) data was collected between 2015 and 2017 (REC: 14/LO/0481). 19 Asthma (n = 12) data was collected between 2012 and 2013 (REC: 11/EM/0402). 33 Cystic fibrosis (n = 19) data was collected between 2013 and 2014 (REC: 12/YH/0343). 34
2.2. Image acquisition
Image acquisition details for CT and 3He MRI across the three studies are provided in Table 1. Additional image acquisition details are given in the subsequent sections.
TABLE 1.
Study: | Name: | Study 1 | Study 2 | Study 3 |
---|---|---|---|---|
Disease: | Lung cancer | Asthma | Cystic fibrosis | |
Total subjects: | 16 | 12 | 19 | |
CT scans: | Acquisition orientation: | Axial | Axial | Axial |
Dose mode: | Radiotherapy planning | High resolution | Ultra‐low dose (expiration) & low dose (inhalation) | |
Breathing inflation: | FRC & FRC+1L | FRC & TLC | Inspiratory & expiratory breath‐hold | |
Slice thickness: | 2.5 mm | ∼ 2.1 mm | 2.5 mm | |
In‐plane resolution: | ∼ 0.98 × 0.98 mm2 | ∼ 0.8 × 0.8 mm2 | ∼ 0.6 × 0.6 mm2 | |
Tube voltage / Current: | 120 kV / 315 mA | 120 kV / 120 mA | 80‐100 kV / 25−150 mA | |
Hyperpolarized gas MRI scans: | Hyperpolarized gas: | 3He | 3He | 3He |
Dimension: | 3D | 2D | 2D | |
Sequence: | Balanced steady‐state free precession | Spoiled gradient echo | Spoiled gradient echo | |
Acquisition orientation: | Coronal | Coronal | Coronal | |
Breathing inflation: | FRC+1L | FRC+1L | FRC+1L | |
Slice thickness: | 5 mm | 10 mm | 10 mm | |
In‐plane resolution: | ∼ 4 × 4 mm2 | ∼ 3 × 3 mm2 | ∼ 3 × 3 mm2 | |
TR / TE: | 1.9 / 0.6 msec | 3.6 / 1.1 msec | 3.6 / 1.1 msec | |
Field of view: | 40 cm | 38.4 cm | 30‐40 cm | |
Flip angle: | 10° | 8° | 8° | |
Bandwidth: | ±166.6 kHz | ±63 kHz | ±63 kHz | |
Time‐difference: | Same day | < 4 days | Same day |
Abbreviations: 1L, 1 liter; 2D, 2‐dimensional; 3D, 3‐dimensional; 3He, helium‐3; CT, computed tomography; FRC, functional residual capacity; MRI, magnetic resonance imaging.; SD, standard deviation; TE, echo time; TR, repetition time.
2.2.1. CT acquisition
Study 119: comprised 16 lung cancer participants. All participants underwent radiotherapy planning breath‐hold CT on a 16‐slice Lightspeed scanner (GE Healthcare, Princeton, New Jersey, USA); each acquisition was acquired within 15−20 s.
Study 233: comprised 12 asthma participants. All participants underwent high‐resolution breath‐hold CT with a Sensation 16 CT scanner (Siemens, Forchheim, Germany).
Study 334: comprised 19 cystic fibrosis participants. All cystic fibrosis participants underwent low dose inspiratory and ultra‐low dose expiratory non‐contrast CT imaging, following the protocol of Loeve et al., 35 on a GE Lightspeed VCT 64 CT scanner (GE Healthcare, Milwaukee, Wisconsin, USA). The CT scanner tube voltage was 80 kV for children weighing < 35 kg and 100 kV for those weighing 35 kg and above. Inspiratory scans were performed with a modulating tube current (max 150 mA) and expiratory scans were performed at a fixed current of 25 mA; as a result, expiratory scans were lower dose.
2.2.2. MRI acquisition
All subjects underwent 3D volumetric 3He hyperpolarized gas MRI in the coronal plane at FRC+1L with full lung coverage at 1.5T on a HDx scanner (GE Healthcare, Milwaukee, Wisconsin, USA). Helium was polarized on‐site to around 25% polarization (GE Healthcare, Amersham, UK). Flexible quadrature radiofrequency coils were employed for transmission and reception of MR signals at the Larmor frequency of 3He (Clinical MR Solutions, Brookfield, WI, USA). An anatomical proton (1H) MRI in the same breath as 3He MRI was acquired for each patient. Details of this acquisition for each study are provided below:
Study 119: Same‐breath 1H MRI scans were acquired at the same resolution as 3He MRI using the scanner's inbuilt body coil with a 3D spoiled gradient‐echo sequence. Repetition time/echo time were equal to 1.9/0.6 ms with a flip angle of 5° and ± 83.3 kHz bandwidth.
Study 233: Same‐breath 1H MRI scans were acquired at the same slice thickness as 3He MRI with an in‐plane resolution of 3 × 6 mm2 using the scanner's inbuilt body coil with a 2D steady‐state free‐precision sequence. Repetition time/echo time was equal to 2.4/0.7 ms with a flip angle of 50° and ± 167 kHz bandwidth.
Study 334: Same‐breath 1H MRI scans were acquired at the same resolution as 3He MRI using an eight‐element chest receiver array with a 2D steady‐state free‐precession sequence. Repetition time/echo time was equal to 2.9/0.9 ms with a flip angle of 50° and ± 250 kHz bandwidth.
2.3. Image segmentation
The Chest Imaging Platform (CIP) 36 (Harvard, Massachusetts, USA) was used to generate segmentations of the lung parenchyma on inspiratory and expiratory CT scans. These segmentations were subsequently reviewed and manually edited by multiple experienced observers, specifically, B.A.T and J.R.A. Segmentation of the lung parenchyma from 1H MRI scans was conducted using spatial fuzzy c‐means clustering. 37 1H MRI segmentations were subsequently manually edited by two experienced observers, namely, B.A.T and P.J.C.H; both observers have a PhD in respiratory imaging.
2.4. Image registration
Inspiratory and expiratory CT scans were aligned using deformable image registration and subsequently registered to the spatial domain of 3He MRI via a corresponding anatomical 1H MRI scan as previously described. 19 , 38 Registration pipelines consisted of rigid, affine and diffeomorphic stages. All registrations were conducted using the advanced normalization tools (ANTs) registration framework 39 based on parameters provided previously. 40 For each patient, two registrations were performed:
Inspiratory CT to expiratory CT
Expiratory CT to 1H MRI (same‐breath as 3He MRI)
Figure 1 shows example unregistered inspiratory and expiratory CT images with the corresponding warped CT images in the domain of 3He MRI. Registrations were quantitatively assessed for overlap using the DSC. 41
2.5. CT ventilation modeling
CT‐based surrogate ventilation images were computed using the CTHU model‐based metric originating from theory proposed by Simon et al. 42 CTVI scans were generated at expiratory geometry and computed using voxel‐wise intensity differences in HU values based on the formulation by Guerrero et al. 9 shown below:
(1) |
where represents the HU of voxels in the warped inspiratory scan that spatially correspond to voxels in the expiratory scan. and represent the HU of inspiratory and expiratory voxels, respectively. CTHU aims to measure the change in the fractional content of air, in a voxel‐wise manner, between expiratory and inspiratory phases. 43 The method assumes that there is uniform air distribution in a given parenchymal voxel and that the observed change in lung density between respiratory phases is attributable solely to changes in ventilation. Tahir et al. 19 previously demonstrated improved performance of the CTHU metric over other CTVI metrics, such as CTJAC, via Spearman's correlation with hyperpolarized gas MRI on a subset of the data used in this study. Several CTVI works have employed various degrees of filtering to account for image noise and possible registration errors. 15 , 19 , 44 , 45 This has previously been used for post‐processing of CTHU ventilation images in the range of 1 × 1 × 1 to 7 × 7 × 7 median filtering. 19 To this end, we applied median filtering to CTHU ventilation images across the whole lung region with a kernel size 6 × 6 × 1, due to the anisotropic resolution of 3He MRI.
3. DEEP LEARNING EXPERIMENTS AND EVALUATION
3.1. CNN architecture configurations
We evaluated four CNN configurations using either single‐channel or multi‐channel inputs as follows:
expiratory CT
inspiratory CT
expiratory CT + inspiratory CT
inspiratory CT + expiratory CT + CTHU model
For each configuration, input feature maps constituting patches of 128 × 128 × 48 voxels were used due to memory constraints. Patches were fed into a 3D fully convolutional neural network with VNet architecture. 46 The network consisted of convolutional steps containing between one and three convolutional layers with subsequent deconvolutional steps, enforcing the original input resolution. As demonstrated by Milletari et al., 46 each step is designed to learn residual functions by initially processing the first convolutional layer using a non‐linear activation function and subsequently replicating this output to the last convolutional layer within the step. 46 Convolutional operations in the initial input block used two convolutional layers with 5 × 5 × 5 kernels and a stride of 1 followed by 2 × 2 × 2 kernels with a stride of 2 to reduce image dimensionality. For the multi‐channel configurations 3) and 4), we concatenated network blocks, combining the feature maps from spatially aligned inspiratory CT, expiratory CT and CTHU modeling. This allowed the network to make use of concordant features represented across multiple inflation levels and modalities. 47 The rest of the network consisted of four convolutional blocks that contained a varying number of convolutional layers with either 5 × 5 × 5 kernels with a stride of 1 or 2 × 2 × 2 kernels with a stride of 2, resulting in a maximum of 248 channels. Each convolutional operation employed a PReLU non‐linear activation function with valid padding. Subsequent deconvolutional blocks, with the same structure as the convolutional blocks, were used to reduce the number of channels. Fine‐grained feature forwarding introduced residual functions to corresponding convolution and deconvolution steps. The final output block made use of a 1 × 1 × 1 convolutional layer.
3.2. CNN training parameters
All hyperpolarized gas MRI, CT and CTHU ventilation scans were masked by their respective lung parenchymal segmentations, thereby eliminating the effect of background voxels and allowing the network to focus on features within the lung parenchyma. All hyperpolarized gas MRI scans used in the dataset underwent pre‐processing to normalize image intensities to values between 0 and 1. Training data was augmented to reduce overfitting whilst still maintaining physiological plausibility. To do this, we employed constrained random rotations with limits −10° to 10° and scaling of −10% to 10%, where a different random rotation or scaling for each axis was applied at an interval within the defined limits above. The data augmentation method used does not increase the overall number of scans in the dataset; instead, each scan is given random scaling and rotation factors before being fed into the network. Therefore, the number of epochs can be increased as each time a scan is passed through the network, it is plausibly augmented by a different random factor at each epoch. Batch normalization was applied for each pass using a mini‐batch size of 2 with the aim of reducing covariate shift between network layers. 48 The weights of the network were trained from scratch and initialized using Xavier initialization, representing a Gaussian distribution with mean of 0 and variance of 1/N, where N represents the number of weights and biases. A root mean square error (RMSE) loss was used to optimize the network employing Adam 49 optimization with an initial learning rate of 1 × 10−5, reducing by a factor of 10 after 1500 epochs and trained for a total of 2150 epochs. L2 regularization with a decay of 0.00001 was used to penalize large network weights and minimize potential overfitting. Training and testing were performed using TensorFlow 50 1.15 and Python 3.6. 51 Training was parallelized across four NVIDIA Tesla V100 GPUs each with 16GB of RAM.
Due to the somewhat limited size of the dataset, we employed 6‐fold stratified cross‐validation, generating six separately trained models tested on a random subset of 7 or 8 patients. The use of cross‐validation to increase the size of the testing set allowed for inferential statistical analyses to be conducted. Each model was stopped at 2150 epochs to constrain model training, mitigating overfitting. All DL configuration outputs were subsequently median filtered with a kernel size of 6 × 6 × 1 in line with the filtering applied to CTHU ventilation images.
3.3. Quantitative evaluation
Synthetic ventilation images generated via the CTHU method and DL configurations were quantitatively evaluated using both voxel‐wise and clinical metrics. Following previous works in the CTVI field and the VAMPIRE grand challenge, Spearman's correlation (𝜌) was selected as the primary evaluation metric. 22 DL‐based methods were additionally assessed using the MSE metric. Further, based on voxel‐wise evaluation metrics, the clinical metric of VLP was computed on the best performing approach. Furthermore, regional localization of ventilated and defect lung regions was assessed via the DSC.
3.3.1. Spatial correlation
The spatial correlations of the DL‐generated synthetic ventilation images and the CTHU model against corresponding 3He MRI scans were assessed at full resolution using Spearman's 𝜌 on all voxels within the lung region, defined by the same‐breath 1H MRI lung segmentation. Spearman's 𝜌 quantifies the degree of monotonicity between any two ventilation images. It takes a range between −1 and 1 where 1 represents a perfect positive correlation and −1 represents a perfect negative correlation. Consequently, a Spearman's 𝜌 of 0 represents no correlation. Spearman's 𝜌 was used as the primary evaluation metric in this work.
3.3.2. Mean square error
Quantitative performance was further evaluated for all DL‐based approaches using the voxel‐wise MSE metric. The MSE represents the mean square difference between estimated values and actual values across all voxels within the lung region. MSE is derived from the square of errors and, therefore, always takes a positive value with the MSE approaching 0 as the error concordantly decreases.
3.3.3. Clinical evaluation
The quantitative biomarker of the VLP has been used extensively in the hyperpolarized gas MRI literature as a robust measure of lung function. VLP is calculated by comparing structural and ventilated lung segmentations to generate a percentage value of ventilated lung volume as follows:
(2) |
In our clinical lung image analysis workflow, VLP values are derived from expert segmentations of hyperpolarized gas MRI for ventilated lung volumes and 1H MRI for total lung volume. 8 In this study, we compared these expert VLP values to VLP values derived using the same 1H MRI expert segmentations for total lung volume and DL‐generated ventilated lung segmentations. We used a previously validated nn‐UNet CNN developed for automatic hyperpolarized gas MRI segmentation 52 to segment synthetic ventilated lung regions from the best performing DL configuration and the CTHU ventilation model. These segmentations were used to calculate VLP automatically without manual editing. Figure 2 depicts a high‐level description of the hybrid model/DL workflow and the automatic calculation of VLP values using DL and expert approaches. In addition to VLP values, DSC overlap values were computed between DL‐generated or CTHU‐generated ventilated lung segmentations and expert 1H MRI segmentations to define both ventilated and defect regions.
3.3.4. Statistical analysis
Statistical analysis was performed using GraphPad Prism 9 (GraphPad, San Diego, CA). In this work, a p‐value < 0.05 was considered statistically significant. A one‐way repeated measures analysis of variance (ANOVA) test for multiple comparisons was used to determine differences between DL configurations for both voxel‐wise Spearman's 𝜌 and MSE. Post‐hoc paired t‐tests were used to assess differences in Spearman's 𝜌 between the CTHU ventilation model and the four DL configurations compared to the reference 3He MRI ventilation scans. Kruskal‐Wallis tests were used to assess differences in Spearman's 𝜌 between the three studies contained within the dataset. Bland‐Altman analyses of bias were used to compare expert VLP values to DL‐derived and CTHU‐derived VLP values for the best performing DL‐based configuration. Paired t‐tests were used to assess differences in overlap of ventilated and defect lung regions for the best performing DL configuration and the CTHU ventilation model.
4. RESULTS
4.1. Image registration
Registrations between inspiratory CT and expiratory CT, and expiratory CT and 1H MRI were evaluated using the DSC metric. All studies generated a median (range) DSC value exceeding 0.98 for inspiratory and expiratory CT, and 0.91 for expiratory CT and 1H MRI (see Table 2).
TABLE 2.
Study |
Insp CT to Exp CT Median DSC (range) |
Exp CT to 1H MRI Median DSC (range) |
---|---|---|
Study 1 | 0.984 (0.969, 0.989) | 0.963 (0.942, 0.973) |
Study 2 | 0.986 (0.977, 0.988) | 0.948 (0.930, 0.960) |
Study 3 | 0.983 (0.970, 0.990) | 0.919 (0.864, 0.955) |
Median (range) DSC values are given for the three studies comprising the data used in this work.
4.2. Qualitative and quantitative evaluation
Qualitatively, there are numerous examples of the hybrid DL‐generated synthetic ventilation images accurately replicating gross ventilation defects in the ground‐truth hyperpolarized gas MRI scans. Figure 3 shows qualitative spatial agreement between 3He MRI and synthetic ventilation approaches for three example cases. For the three cases displayed, the hybrid DL method, with inspiratory CT, expiratory CT and the CTHU model as inputs, generated the highest Spearman's 𝜌 compared to the CTHU model and all other DL configurations. For Case 1, the differences in performance between DL configurations demonstrate that when a singular structural image is used as an input, the resulting synthesized ventilation scan is unable to capture gross ventilation defects in the left lung; however, when the hybrid DL configuration is utilized, the resulting synthetic scan accurately captures gross ventilation defects which mirror defects observed in the hyperpolarized gas MRI scan.
Significant differences between methods were determined by a one‐way ANOVA test (P < 0.05). The hybrid method yielded statistically significant improvements in Spearman's 𝜌 compared to the CTHU model with mean ± SD 𝜌 of 0.57 ± 0.17 versus 0.51 ± 0.22 (P = 0.003). Furthermore, this approach significantly outperformed all other DL configurations, which did not employ the CTHU model as an input (P < 0.05). DL‐based approaches were additionally assessed using voxel‐wise MSE; the hybrid configuration generated the lowest MSE based on descriptive statistics. No significant differences were observed between the three best performing DL‐methods using the MSE metric. Table 3 summarizes the descriptive statistics for all methods across 47 patients via six‐fold cross‐validation.
TABLE 3.
Spearman's 𝜌 | MSE | |
---|---|---|
Synthetic ventilation generation method | Mean ± SD | Mean ± SD |
CTHU model | 0.51 ± 0.22 | N/A |
DL (expiration CT) | 0.52 ± 0.20 | 0.024 ± 0.01 |
DL (inspiration CT) | 0.47 ± 0.21 | 0.020 ± 0.01 |
DL (expiration CT + inspiration CT) | 0.52 ± 0.19 | 0.020 ± 0.01 |
DL (expiration CT + inspiration CT + CTHU model) | 0.57 ± 0.17 | 0.017 ± 0.01 |
Mean ± SD Spearman's 𝜌 for the DL configurations and the CTHU model are shown. Additionally, mean ± SD MSE are given for the DL configurations. The best 𝜌 and MSE values are shown in bold.
Figure 4 shows Spearman's correlations between 3He hyperpolarized gas MRI for both the CTHU ventilation model and DL‐based configurations; the proposed hybrid framework demonstrated significantly greater Spearman's correlations when compared to all other DL configurations and the CTHU ventilation model. Additionally, MSEs between 3He hyperpolarized gas MRI and DL configurations are displayed, indicating minimal significant differences between DL configurations.
The dataset contains scans from three independent research studies with varying acquisition protocols from participants with varying pulmonary pathologies. No significant difference in Spearman's ρ between datasets was observed using the CTHU ventilation model. A significant difference was observed between the Spearman's 𝜌 of Study 1 and Study 3 using the hybrid DL configuration (P = 0.03); no other significant differences were observed (Study 1 vs. Study 2, P = 0.93; Study 2 vs. Study 3, P = 0.51).
4.3. Clinical evaluation
The hybrid model/DL configuration exhibited significant improvements in Spearman's 𝜌 when compared to all other methods investigated. Therefore, we further investigated this configuration using a clinical metric, namely, VLP. Using the workflow defined in Figure 2, we compared expert VLP values to those computed from synthetic ventilation scans generated by the hybrid configuration. Figure 5 shows fused structural and functional images with corresponding VLP values for four cases in the dataset. Cases with significant ventilation defects were chosen to illustrate the hybrid framework's ability to replicate gross defects. For example, Case 2 shows almost no ventilation signal in the left lung of the hyperpolarized gas MRI scan which is largely replicated in the output of the hybrid configuration. We used Bland‐Altman analyses of bias to compare VLP values derived from hyperpolarized gas MRI versus VLP values derived using the hybrid DL configuration and the CTHU ventilation model as shown in Figure 6. The hybrid DL synthetic ventilation surrogates resulted in a bias of only 3.04% with limits of agreement (LoA) of −15.45% to 21.53% compared to the CTHU ventilation model which produced a bias of −10.74% with LoA of −47.55% to 26.07%.
DSC values of ventilated and defect lung regions for the hybrid DL and CTHU model are compared to expert ventilated and defect lung regions computed using hyperpolarized gas MRI (see Table 4). The hybrid DL configuration produced significantly greater DSC values for both the ventilated and defect lung regions, achieving a median (range) DSC of 0.946 (0.715, 0.977) and 0.483 (0.288, 0.743) for ventilated and defect lung regions, respectively.
TABLE 4.
Region | Hybrid DL | CTHU |
---|---|---|
Ventilated lung | 0.946 (0.715, 0.977) | 0.903 (0.046, 0.956) |
Defect lung | 0.483 (0.288, 0.743) | 0.426 (0.049, 0.730) |
The best DSC values are shown in bold.
5. DISCUSSION
In this work, we proposed a hybrid model‐ and DL‐based framework, integrating CTHU models of lung ventilation and structural, multi‐inflation CT as inputs to a VNet CNN capable of producing synthetic ventilation scans that correlated well with corresponding ground‐truth 3He MRI ventilation scans. To the best of our knowledge, this work represents the first use of DL to predict hyperpolarized gas MRI ventilation directly from multi‐inflation CT. As shown in Figures 3 and 5, the synthetic ventilation scans generated using the hybrid framework mimic moderate‐to‐large defects present in the corresponding 3He MRI scans. This has the potential to produce DL‐based synthetic ventilation scans from routinely acquired CT scans without exogenous contrast. Compared with conventional CTHU modeling, the hybrid framework yields a statistically significant improvement in spatial correlation. The comparison with CTHU ventilation surrogates is somewhat limited due to the inclusion of pulmonary vessels in CTHU images. Commonly, vessels are excluded from CTHU images; however, this adds a significant time‐consuming manual intervention step. The hybrid configuration developed here can potentially learn to accommodate pulmonary vessels without manual intervention through learning mechanisms. 1H MRI scans used in this study were acquired using spoiled‐gradient echo sequences; pulmonary vessels are significantly more challenging to identify using these sequences compared to balanced steady‐state free‐precession MRI 53 or CT; hence delineating corresponding vessels in imaging modalities is a significant challenge. In addition to outperforming conventional CTHU modeling, the hybrid configuration significantly outperformed all other DL configurations using Spearman's correlation, indicating the significant benefit of leveraging classical modeling and data‐driven approaches. The hybrid configuration's performance is further enhanced by harnessing a combination of structural and functional modalities. Functional CTHU ventilation images have demonstrated moderate correlation with hyperpolarized gas MRI previously 19 ; however, differences remain. By combining structural CT images at multiple inflations with CTHU images, additional information contained within the structural images can be utilized to modify the predicted ventilation image via a deep learning approach. The measured Spearman's correlations of the CTHU model and the hybrid configuration demonstrate some correlation with each other, but, crucially the inclusion of structural CT images in combination with the CTHU images as inputs generated a significant improvement in Spearman's 𝜌 compared to the conventional CTHU method or the DL configurations not integrating CTVI modeling. Although Spearman's 𝜌 was utilized as the primary evaluation metric, performance was also evaluated using the MSE. The MSE was not calculated for the CTHU ventilation model as this model is directly derived from HU values, which have physiological meaning, limiting a direct quantitative comparison with hyperpolarized gas MRI where specific voxel intensity values are arbitrary and not consistent between scans. The MSE was calculated for all DL configurations, indicating minimal significant differences between DL configurations; this is potentially due to the MSE assessing specific values of intensity, compared to correlations between corresponding voxel intensities, and may be less important than correlated regions of low intensity.
We evaluated the hybrid framework on a diverse and challenging dataset using six‐fold cross‐validation. The dataset contained scans of patients with one of three lung pathologies, namely, lung cancer, moderate‐to‐severe asthma or mild cystic fibrosis. The scans were pooled from three separate clinical studies, resulting in a wide range of acquisition protocols in the dataset: high‐dose and low‐dose CT; different CT scanner types, settings and breathing maneuvers; 2D versus 3D 3He MRI; differences in in‐plane resolutions and slice thicknesses. The proposed hybrid framework exhibited some differences between studies present in the dataset, that is, between Study 1 and Study 3; however, it cannot be determined whether this variation in performance is due to differences in participant disease or the image acquisition parameters used. The lack of differences when comparing performance of the remaining study combinations indicates a level of robustness and generalizability to both disease and acquisition parameters. 6‐fold cross‐validation was employed, resulting in six separately trained models. This expanded the number of scans available for evaluation; however, the dataset remains relatively limited in size, containing only 47 patients. Future work will aim to expand the dataset further and investigate novel data augmentation techniques, including synthetic data generation. There is a potential that, as the amount of available representative scans increases, configurations excluding CTVI modeling may generate synthetic ventilation images that are more correlated with hyperpolarized gas MRI scans. In future work, if the dataset is expanded, we can assess whether the inclusion of the CTVI modeling still provides significant performance benefits.
The VNet CNN architecture was used due to its fully convolutional nature. Fully convolutional networks contain no fully connected layers and hence contain significantly fewer parameters than conventional networks with fully connected layers; this minimizes the network's ability to simply memorize scans within the training set, referred to as overfitting. The fully convolutional VNet not only reduces the overall number of parameters but also makes the number of parameters independent of image matrix size. Therefore, the network was trained and tested on scans with different matrices and acquisition protocols using fixed‐size patches of 128 × 128 × 48 voxels. We further reduced the possibility of overfitting using L2 weight regularization with a decay of 0.00001 to penalize large network weights.
Segmentations of ventilated lung volumes derived from hyperpolarized gas MRI and thoracic cavity volumes derived from structural 1H MRI segmentations have been extensively used in the literature to generate VLPs, an established biomarker of regional lung function. 7 We demonstrated that VLPs derived from the proposed hybrid framework are comparable with ground truth VLPs from 3He MRI, producing a significantly reduced bias compared to the CTHU method. Bland‐Altman analysis of bias, however, indicated that there was reduced accuracy in patients with more significant ventilation defects, resulting in higher predicted VLP values than the corresponding expert values. In addition to VLP analysis, synthetic ventilation scans were segmented using a DL‐based segmentation algorithm 52 to provide regional localized comparisons of ventilated and defect lung regions. The hybrid DL configuration generated a median DSC of 0.95 for ventilated regions and 0.48 for defect regions, significantly outperforming the DSC achieved by the CTHU method. Both VLP values and regional overlap values require the segmentation of synthetic ventilation scans and are, therefore, susceptible to biases in the segmentation algorithm used; the automatic segmentation method used here was trained to segment hyperpolarized gas MRI and not synthetic ventilation scans. 52 There is limited consensus on the appropriate segmentation schema required for the delineation of ventilated and defect regions, resulting in an inability to produce accurate comparisons between research studies. It is possible that ventilated lung regions were overestimated during segmentation due to the less pronounced changes in ventilation heterogeneity. Further investigation to improve automatic segmentation of synthetic ventilation scans generated by the hybrid configuration could reduce these biases.
As previously demonstrated by Levin et al., 54 the minimum resolution of functional lung images need not be higher than the smallest pulmonary gas exchange unit, namely, the acinus, which has been estimated to be on the order of 10 × 10 × 10 mm3 in adult humans. They further indicate that resolutions of 20 × 20 × 20 mm3 may be appropriate due to the spatial clustering of most ventilation defects. 54
Our study only investigates one CTVI modeling method, namely, CTHU; however, several other CTVI methods have been used in the literature. Subsequent research will aim to assess the differences in performance of the hybrid approach using classical CTVI metrics, such as CTJAC, and emerging metrics with more robust formulations. 10 , 55 One key consideration is the requirement of accurate registration between multi‐inflation CT and hyperpolarized gas MRI. Building a network capable of synthesizing ventilations scans independent of image registration would reduce the computational costs and time taken to generate synthetic images. Both the CTHU metric and the proposed hybrid model rely on accurate registrations and, consequently, are susceptible to errors in cases where the registration is suboptimal. Removing this requirement would eliminate biases due to errors in registration.
A previous approach by Westcott et al. 56 utilized texture analysis, feature selection and classical machine learning methods to generate synthetic lung ventilation maps from thoracic CT in COPD patients. They evaluated the synthetic ventilation maps using whole‐lung metrics; however, more accurate voxel‐wise evaluation metrics were not reported.
The ability to generate synthetic ventilation scans from CT has implications for several clinical applications, including functional lung avoidance radiotherapy 3 , 4 and treatment response mapping. 5 Kida et al. 57 has previously demonstrated that a Spearman's 𝜌 of ∼0.4 between CTHU and SPECT images produces clinically indistinguishable radiotherapy plans. In this study, we observed correlations of ∼0.6 between the hybrid DL configuration and hyperpolarized gas MRI, indicating the former's potential clinical utility in functional lung avoidance radiotherapy. Synthesizing hyperpolarized gas MRI in comparison to other functional lung imaging modalities such as SPECT has several advantages, including enhanced spatial and temporal resolution and the lack of aerosol deposition artifacts or time‐delayed ventilation filling effects. CT is an integral part of almost every clinical lung imaging workflow and hence is readily available for most patients; therefore, synthetic ventilation from non‐contrast CT can provide patients with wider access to ventilation imaging worldwide.
6. CONCLUSION
We propose a hybrid model/DL framework to synthesize ventilation scans from routinely acquired non‐contrast multi‐inflation CT and classical CTVI modeling. We show that a synergy between model‐based CTVI and CNN‐based learning yields statistically significant improvements in performance compared with conventional CTVI modeling alone and other DL configurations that do not integrate modeling.
CONFLICT OF INTEREST
The authors have no conflicts of interest to declare.
ACKNOWLEDGMENTS
This work was supported by Yorkshire Cancer Research (S406BT), National Institute of Health Research (NIHR‐RP‐R3‐12‐027), and the Medical Research Council (MR/M008894/1). The authors acknowledge access to high‐performance computing equipment available via an EPSRC Equipment Grant (EP/P020275/1) and support provided via Research Software Engineering Sheffield.
Astley JR, Biancardi AM, Marshall H, et al. A hybrid model‐ and deep learning‐based framework for functional lung image synthesis from multi‐inflation CT and hyperpolarized gas MRI. Med Phys. 2023;50:5657–5670. 10.1002/mp.16369
DATA AVAILABILITY STATEMENT
The imaging datasets generated and/or analysed during the current study are not publicly available as they were generated as part of an industrial collaborative study that is still underway. Requests for data should be addressed to B.A.T.
REFERENCES
- 1. Vos T, Abajobir AA, Hassen Abate K, et al. Global, regional, and national incidence, prevalence, and years lived with disability for 328 diseases and injuries for 195 countries, 1990–2016: a systematic analysis for the Global Burden of Disease Study 2016. Lancet. 2017;390(10100):1211‐1259. 10.1016/S0140-6736(17)32154-2 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2. Torre LA, Bray F, Siegel RL, Ferlay J, Lortet‐Tieulent J, Jemal A. Global cancer statistics, 2012. CA Cancer J Clin. 2015;65(2):87‐108. 10.3322/caac.21262 [DOI] [PubMed] [Google Scholar]
- 3. Tahir BA, Bragg CM, Wild JM, et al. Impact of field number and beam angle on functional image‐guided lung cancer radiotherapy planning. Phys Med Biol. 2017;62(17):7114‐7130. 10.1088/1361-6560/aa8074 [DOI] [PubMed] [Google Scholar]
- 4. Ireland RH, Tahir BA, Wild JM, Lee CE, Hatton MQ. Functional Image‐guided Radiotherapy Planning for Normal Lung Avoidance. Clin Oncol (R Coll Radiol). 2016;28(11):695‐707. 10.1016/j.clon.2016.08.005 [DOI] [PubMed] [Google Scholar]
- 5. Horn FC, Marshall H, Collier GJ, et al. Regional ventilation changes in the lung: treatment response mapping by using hyperpolarized gas MR imaging as a quantitative biomarker. Radiology. 2017/09/01 2017;284(3):854‐861. 10.1148/radiol.2017160532 [DOI] [PubMed] [Google Scholar]
- 6. Fain SB, Korosec FR, Holmes JH, O'Halloran R, Sorkness RL, Grist TM. Functional lung imaging using hyperpolarized gas MRI. J Magn Reson Imaging. 2007;25(5):910–923. 10.1002/jmri.20876 [DOI] [PubMed] [Google Scholar]
- 7. Woodhouse N, Wild JM, Paley MN, et al. Combined helium‐3/proton magnetic resonance imaging measurement of ventilated lung volumes in smokers compared to never‐smokers. J Magn Reson Imaging. 2005;21(4):365‐9. 10.1002/jmri.20290 [DOI] [PubMed] [Google Scholar]
- 8. Stewart NJ, Smith LJ, Chan HF, et al. Lung MRI with hyperpolarised gases: current & future clinical perspectives. Br J Radiol. 2021:20210207. 10.1259/bjr.20210207 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9. Guerrero T, Sanders K, Noyola‐Martinez J, et al. Quantification of regional ventilation from treatment planning CT. Int J Radiat Oncol Biol Phys. 2005;62(3):630‐4. 10.1016/j.ijrobp.2005.03.023 [DOI] [PubMed] [Google Scholar]
- 10. Reinhardt J, Ding K, Cao K, Christensen G, Hoffman E, Bodas SV. Registration‐based estimates of local lung tissue expansion compared to xenon CT measures of specific ventilation. Med Image Anal. 2008;12 6:752‐63. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11. Ding K, Cao K, Fuld M, et al. Comparison of image registration based measures of regional lung ventilation from dynamic spiral CT with Xe‐CT. Med Phys. 2012;39 8:5084‐98. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12. Brennan D, Schubert L, Diot Q, et al. Clinical Validation of 4‐Dimensional Computed Tomography Ventilation With Pulmonary Function Test Data. Int J Radiat Oncol Biol Phys. 2015;92(2):423‐429. 10.1016/j.ijrobp.2015.01.019 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13. Yamamoto T, Kabus S, Lorenz C, et al. Pulmonary ventilation imaging based on 4‐dimensional computed tomography: comparison with pulmonary function tests and SPECT ventilation images. Int J Radiat Oncol*Biol*Phys. 2014/10/01/2014;90(2):414‐422. doi: 10.1016/j.ijrobp.2014.06.006 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14. Castillo R, Castillo E, Martinez JG, Guerrero T. TU b 204b 04: ventilation from four dimensional computed tomography: density versus Jacobian methods. Med Phys. 2010;37:3377‐3377. [DOI] [PubMed] [Google Scholar]
- 15. Kipritidis J, Siva S, Hofman M, Callahan J, Hicks R, Keall P. Validating and improving CT ventilation imaging by correlating with ventilation 4D‐PET/CT using Ga‐68‐labeled nanoparticles. Med Phys. 2014;41:011910. 10.1118/1.4856055 [DOI] [PubMed] [Google Scholar]
- 16. Yamamoto T, Kabus S, Berg J, Lorenz C, Goris ML, Loo B, Keall P. Evaluation of Four‐dimensional (4 D) Computed Tomography (CT) Pulmonary Ventilation Imaging by Comparison with Single Photon Emission Computed Tomography (SPECT) Scans for a Lung Cancer Patient. Proceedings of the Third International Workshop on Pulmonary Image Analysis. 2010; 117‐128.
- 17. Jögi J, Jonson B, Ekberg M, Bajc M. Ventilation‐perfusion SPECT with 99mTc‐DTPA versus Technegas: a head‐to‐head study in obstructive and nonobstructive disease. J Nucl Med. 2010;51(5):735‐41. 10.2967/jnumed.109.073957 [DOI] [PubMed] [Google Scholar]
- 18. Magnant J, Vecellio L, de Monte M, et al. Comparative analysis of different scintigraphic approaches to assess pulmonary ventilation. J Aerosol Med. 2006/06/01 2006;19(2):148‐159. 10.1089/jam.2006.19.148 [DOI] [PubMed] [Google Scholar]
- 19. Tahir BA, Hughes PJC, Robinson SD, et al. Spatial comparison of CT‐based surrogates of lung ventilation with hyperpolarized helium‐3 and Xenon‐129 gas MRI in patients undergoing radiation therapy. Int J Radiat Oncol Biol Phys. 2018;102(4):1276‐1286. 10.1016/j.ijrobp.2018.04.077 [DOI] [PubMed] [Google Scholar]
- 20. Astley JR, Wild JM, Tahir BA. Deep learning in structural and functional lung image analysis. Br J Radiol. 2020;0(0):20201107. 10.1259/bjr.20201107 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21. Zhong Y, Vinogradskiy Y, Chen L, et al. Technical Note: Deriving ventilation imaging from 4DCT by deep convolutional neural network. Med Phys. 2019;46(5):2323‐2329. 10.1002/mp.13421 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22. Kipritidis J, Tahir BA, Cazoulat G, et al. The VAMPIRE challenge: A multi‐institutional validation study of CT ventilation imaging. Med Phys. 2019;46(3):1198‐1217. 10.1002/mp.13346 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23. Ren G, Li B, Lam S‐k, et al. A transfer learning framework for deep learning‐based CT‐to‐perfusion mapping on lung cancer patients. Original research. Front Oncol. 2022;12 10.3389/fonc.2022.883516 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24. Liu Z, Miao J, Huang P, et al. A deep learning method for producing ventilation images from 4DCT: First comparison with technegas SPECT ventilation. Med Phys. 2020;47(3):1249‐1257. 10.1002/mp.14004 [DOI] [PubMed] [Google Scholar]
- 25. Grover J, Byrne HL, Sun Y, Kipritidis J, Keall P. Investigating the use of machine learning to generate ventilation images from CT scans. Med Phys. 2022;49(8):5258‐5267. 10.1002/mp.15688 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26. Marshall H, Deppe MH, Parra‐Robles J, et al. Direct visualisation of collateral ventilation in COPD with hyperpolarised gas MRI. Thorax. 2012;67(7):613. 10.1136/thoraxjnl-2011-200864 [DOI] [PubMed] [Google Scholar]
- 27. Capaldi DPI, Guo F, Xing L, Parraga G. Pulmonary ventilation maps generated with free‐breathing proton MRI and a deep convolutional neural network. Radiology. 2021/02/01 2020;298(2):427‐438. 10.1148/radiol.2020202861 [DOI] [PubMed] [Google Scholar]
- 28. Long Y, She X, Mukhopadhyay S. HybridNet: integrating model‐based and data‐driven learning to predict evolution of dynamical systems. PMLR; 2018:551‐560. [Google Scholar]
- 29. Grover A, Kapoor A, Horvitz E. A Deep Hybrid Model for Weather Forecasting. presented at: Proceedings of the 21th ACM SIGKDD International Conference on Knowledge Discovery and Data Mining; 2015; Sydney, NSW, Australia. 10.1145/2783258.2783275 [DOI] [Google Scholar]
- 30. Goldstein EB, Coco G, Murray AB, Green MO. Data‐driven components in a model of inner‐shelf sorted bedforms: a new hybrid model. Earth Surf Dynam. 2014;2(1):67‐82. 10.5194/esurf-2-67-2014 [DOI] [Google Scholar]
- 31. Hamilton F, Lloyd AL, Flores KB. Hybrid modeling and prediction of dynamical systems. PLoS Comput Biol. 2017;13(7):e1005655. 10.1371/journal.pcbi.1005655 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32. Willard J, Jia X, Xu S, Steinbach M, Kumar V. Integrating physics‐based modeling with machine learning: A survey. arXiv preprint arXiv:200304919. 2020; [Google Scholar]
- 33. Tahir BA, Van Holsbeke C, Ireland RH, et al. Comparison of CT‐based lobar ventilation with 3He MR imaging ventilation measurements. Radiology. 2016;278(2):585‐92. 10.1148/radiol.2015142278 [DOI] [PubMed] [Google Scholar]
- 34. Marshall H, Horsley A, Taylor CJ, et al. Detection of early subclinical lung disease in children with cystic fibrosis by lung ventilation imaging with hyperpolarised gas MRI. Thorax. 2017;72(8):760. 10.1136/thoraxjnl-2016-208948 [DOI] [PubMed] [Google Scholar]
- 35. Loeve M, Lequin MH, de Bruijne M, et al. Cystic fibrosis: Are volumetric ultra‐low‐dose expiratory CT scans sufficient for monitoring related lung disease? Radiology. 2009;253(1):223‐229. 10.1148/radiol.2532090306 [DOI] [PubMed] [Google Scholar]
- 36. San Jose Estepar R, Ross JC, Harmouche R, Onieva J, Diaz AA, Washko GR. Chest Imaging Platform: An Open‐Source Library and Workstation for Quantitative Chest Imaging. C66 LUNG IMAGING II: NEW PROBES AND EMERGING TECHNOLOGIES. American Thoracic Society; 2015:A4975‐A4975. American Thoracic Society International Conference Abstracts. [Google Scholar]
- 37. Hughes PJC, Horn FC, Collier GJ, Biancardi A, Marshall H, Wild JM. Spatial fuzzy c‐means thresholding for semiautomated calculation of percentage lung ventilated volume from hyperpolarized gas and (1) H MRI. J Magn Reson Imaging. 2018;47(3):640‐646. 10.1002/jmri.25804 [DOI] [PubMed] [Google Scholar]
- 38. Tahir BA, Swift AJ, Marshall H, et al. A method for quantitative analysis of regional lung ventilation using deformable image registration of CT and hybrid hyperpolarized gas/1H MRI. Phys Med Biol. 2014;59(23):7267‐77. 10.1088/0031-9155/59/23/7267 [DOI] [PubMed] [Google Scholar]
- 39. Avants B, Tustison N, Song G. Advanced normalization tools (ANTS). Insight J. 2008;1–35 [Google Scholar]
- 40. Tahir BA, Marshall H, Hughes PJC, et al. Comparison of CT ventilation imaging and hyperpolarised gas MRI: effects of breathing manoeuvre. Phys Med Biol. 2019;64(5):055013. 10.1088/1361-6560/ab0145 [DOI] [PubMed] [Google Scholar]
- 41. Dice LR. Measures of the amount of ecologic association between species. Ecology. 1945;26(3):297‐302. 10.2307/1932409 [DOI] [Google Scholar]
- 42. Simon B. Non‐invasive imaging of regional lung function using X‐ray computed tomography. J Clin Monit Comput. 2004;16:433‐442. [DOI] [PubMed] [Google Scholar]
- 43. Simon BA, Kaczka DW, Bankier AA, Parraga G. What can computed tomography and magnetic resonance imaging tell us about ventilation? 2012. p. 647–657. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44. Castillo R, Castillo E, Martinez J, Guerrero T. Ventilation from four‐dimensional computed tomography: density versus Jacobian methods. Phys Med Biol. 2010;55(16):4661‐85. 10.1088/0031-9155/55/16/004 [DOI] [PubMed] [Google Scholar]
- 45. Castillo R, Castillo E, McCurdy M, et al. Spatial correspondence of 4D CT ventilation and SPECT pulmonary perfusion defects in patients with malignant airway stenosis. Phys Med Biol. 2012;57(7):1855‐1871. 10.1088/0031-9155/57/7/1855 [DOI] [PubMed] [Google Scholar]
- 46. Milletari F, Navab N, Ahmadi SA. V‐Net: Fully Convolutional Neural Networks for Volumetric Medical Image Segmentation. Proceedings of 2016 Fourth International Conference on 3d Vision (3dv). 2016:565‐571. 10.1109/3dv.2016.79 [DOI] [Google Scholar]
- 47. Berger L, Eoin H, Cardoso MJ, Ourselin S. An adaptive sampling scheme to efficiently train fully convolutional networks for semantic segmentation. Springer; 2018:277‐286. [Google Scholar]
- 48. Ioffe S, Szegedy C. Batch normalization: Accelerating deep network training by reducing internal covariate shift. International Machine Learning Society (IMLS); 2015:448‐456. [Google Scholar]
- 49. Kingma D, Adam Ba J.: A Method for Stochastic Optimization. 2015.
- 50. Abadi M, Agarwal A, Barham P, et al. Tensorflow: Large‐scale machine learning on heterogeneous distributed systems. arXiv preprint arXiv:160304467. 2016; [Google Scholar]
- 51. Gibson E, Li W, Sudre C, et al. NiftyNet: a deep‐learning platform for medical imaging. Comput Methods Programs Biomed. 2018;158:113‐122. 10.1016/j.cmpb.2018.01.025 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52. Astley JR, Biancardi AM, Hughes PJC, et al. Large‐scale investigation of deep learning approaches for ventilated lung segmentation using multi‐nuclear hyperpolarized gas MRI. Sci Rep. 2022;12(1):10566. 10.1038/s41598-022-14672-2 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53. Wild JM, Marshall H, Bock M, et al. MRI of the lung (1/3): methods. Insights into Imaging. 2012;3(4):345‐353. 10.1007/s13244-012-0176-x [DOI] [PMC free article] [PubMed] [Google Scholar]
- 54. Levin DL, Schiebler ML, Hopkins SR. Physiology for the pulmonary functional imager. Eur J Radiol. 2017;86:308‐312. 10.1016/j.ejrad.2016.09.027 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55. Castillo E, Castillo R, Vinogradskiy Y, et al. Robust CT ventilation from the integral formulation of the Jacobian. Med Phys. 2019;46(5):2115‐2125. 10.1002/mp.13453 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56. Westcott A, Capaldi DPI, McCormack DG, Ward AD, Fenster A, Parraga G. Chronic obstructive pulmonary disease: Thoracic CT texture analysis and machine learning to predict pulmonary ventilation. Radiology. 2019;293(3):676‐684. 10.1148/radiol.2019190450 [DOI] [PubMed] [Google Scholar]
- 57. Kida S, Bal M, Kabus S, et al. CT ventilation functional image‐based IMRT treatment plans are comparable to SPECT ventilation functional image‐based plans. Radiother Oncol. 2016/03//2016;118(3):521‐527. 10.1016/j.radonc.2016.02.019 [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
The imaging datasets generated and/or analysed during the current study are not publicly available as they were generated as part of an industrial collaborative study that is still underway. Requests for data should be addressed to B.A.T.