Skip to main content
Journal of International Society of Preventive & Community Dentistry logoLink to Journal of International Society of Preventive & Community Dentistry
. 2023 Nov 7;14(1):43–51. doi: 10.4103/jispcd.jispcd_299_21

Comparative Evaluation of Microtensile Bond Strength in Three Different Dentin Luting Agents: An In vitro Study

Leonor Cristina Castro-Ramirez 1, Marysela Irene Ladera-Castañeda 2, Hernán Rafael Cachay-Criado 1, María Isabel Alvino-Vales 1, Carlos López-Gurreonero 3, Luis Adolfo Cervantes-Ganoza 4, César Félix Cayo-Rojas 1,
PMCID: PMC10980309  PMID: 38559644

ABSTRACT

Aim:

Long-term clinical success on indirect restorations is largely determined by bonding efficiency of the luting agent, with adhesion to dentin being the main challenge. Therefore, aim of this study was to assess the microtensile bond strength when using flowable resin composite, preheated resin composite and dual self-adhesive resin cement as dentin luting agents.

Materials and Methods:

Occlusal thirds of molar teeth were cut and randomly divided into 3 groups to be cemented: RelyX™U200, Filtek™ Z250 XT- preheated to 70° and Filtek Flow™ Z350XT. They were then thermocycled 5000 times between 5+/-2°C and 55+/-2°C. Subsequently, 10 microbars per group were prepared. The 30 samples were placed in saline solution for 24 hours at room temperature prior to microtensile test. This was performed with a digital universal testing machine at a crosshead speed of 0.5 mm/min. The bond strength values obtained were analyzed in Megapascals (MPa). Measures of central tendency such mean and measures of dispersion such standard deviation were used. In addition, the Kruskall Wallis non-parametric test with Bonferroni post hoc test was applied, considering a significance value of 5% (P < 0.05), with type I error.

Results:

The dentin microtensile bond strengths of preheated resin composite, flowable resin composite and dual self-adhesive cement were 6.08 ± 0.66 Mpa, 5.25 ± 2.60Mpa and 2.82 ± 1.26Mpa, respectively. In addition, the preheated resin composite exhibited significantly higher microtensile bond strength compared to the dual self-adhesive cement (P < 0.001). While the flowable resin composite showed no significant difference with the dual self-adhesive cement (P = 0.054) and the preheated resin composite (P = 0.329).

Conclusions:

The microtensile bond strength in dentin was significantly higher when using a preheated resin composite at 70°C as a luting agent compared to dual self-adhesive cement. However, the preheated resin composite showed similar microtensile bond strength compared to the flowable resin composite.

Keywords: Dentistry, flowable resin, luting agent, microtensile bond strength, preheated resin, resin composite

INTRODUCTION

Indirect restorations based on conventional resin composites are an affordable alternative with good esthetic results. Therefore, many dentists prefer them because of their better mechanical performance and significant reduction of shrinkage during polymerization compared to a direct restoration,[1,2,3,4,5] since the direct technique has a volumetric shrinkage rate of 1% to 6%, depending on the composition of the resin and curing conditions, which would be reduced when performing an indirect technique.[4] They also have a lower incidence of fractures compared to ceramics, since these have shown up to 20% fracture rates in studies clinical Class I and II cavities.[3]

Several authors point out that one of main reasons for failure of indirect restorations is due to lack of sealing at the tooth-restoration interface, since the shrinkage produced by polymerization of luting agent would cause the formation of marginal spaces or microgaps around inlay, allowing bacterial infiltration and entry of food debris, which would generate secondary caries.[5,6,7] Therefore, it is considered that long-term clinical success of indirect restorations is largely determined by bonding efficiency of the luting agent.[5,6]

In order to increase the bond strength to dental substrate, some modifications have been made to bonding agents regarding their chemical composition, bonding mechanism, number of steps and application technique. As a result, there are several generations of bonding agents available on the market.[8]

Conventional composite resins continue to be one of the most widely used materials in dentistry, being used in direct and indirect restorations, either as a restorative material or as a luting agent.[9,10] The composition of composite resins is based on an organic matrix with a mixture of monomers such as Bis-GMA (Bisphenol-A-Glycidyl Methacrylate), TEGDMA (Triethylene Glycol Dimethacrylate), UDMA (Urethane Dimethacrylate), HEMA (Hydroxy Ethylmethacrylate), Bis-EMA (Bisphenol A Polyethylene Glycol Diether Dimethacrylate), fillers such as silica, quartz or ceramic glass and a photoinitiator such as camphorquinone, BAPO (Bisacyl Phosphine Oxide) or others, resulting in macroparticulate, microparticulate, nanoparticulate and hybrid composite resins containing particles of different sizes.[9,11,12] On the other hand, when referring to resinous cements, the composition varies, having two main differences: the proportion of monomers used in the mixture and the amount of filler, which confers lower viscosity for higher flow, but at the same time reducing its mechanical properties compared to conventional resin composites.[9,12]

Due to great versatility of resin composites and their superior mechanical properties, alternative techniques have been used to reduce their viscosity and use them as luting agent. The best known is thermoplastic technique, in which resin becomes less viscous when heated due to increased agitation of molecules, providing sufficient viscosity for bonding indirect restorations, similar to resin cements.[9,11] Consequently, preheated composite could be used as luting agent without losing its mechanical strength properties, giving the advantage of greater color shade availability and lower cost, in addition to being able to preheat the same resin syringe up to 20 times without affecting its mechanical properties. However, there is currently no consensus on whether preheated resin composite would increase or decrease the bond strength between the restorative material and the substrate. In addition, there is still some controversy over the thickness of the film formed from it, with some authors claiming that inlay sits well in the cavity, while others do not.[9,13,14]

Another alternative as a luting agent is composite resin as it has lower viscosity due to its low amount of filler and particle size, similar to conventional composite resins. These characteristics give as an advantage greater color stability over time, better diffusion of the material, wide range of colors for different clinical situations, in addition to polymerization shrinkage and film thickness similar to resinous cements. On the other hand, due to its low inorganic filler, it has the disadvantage of higher polymerization shrinkage. However, its low modulus of elasticity would allow shrinkage to take place with little stress, reducing the formation of micro-gaps.[10,15,16,17]

Dual resinous cement, which possesses advantageous characteristics of light-curing and self-curing cements, is also used to cement indirect restorations because of its low solubility, low viscosity, clinically acceptable film thickness, better mechanical properties than conventional cements, good adhesion when used as a bonding agent and less microleakage compared to other luting materials. As a disadvantage, it has been suggested that early vitrification (formation of polymeric networks) induced by light activation could interfere with autopolymerization, thus compromising the degree of conversion. In addition, it has been pointed out that insufficient light exposure could result in incomplete polymerization, with a lower level compared to self-curing resinous cements.[6,18]

Several studies report that bonding to enamel is achieved in a firm and durable manner with relative ease. However, bonding to dentin has been considered more difficult and less predictable due to its heterogeneous nature containing hydroxyapatite deposited on a mesh of hydrophilic collagen fibers, representing a great challenge for bonding agents.[18,19] Since bonding agents are of utmost importance for preservation of the restoration, it has been suggested to carry out more in vitro research on adhesive tests, the most widely used being microtraction or microtensile tensile strength.[19,20] In view of the above, the constant evolution of dental materials leads to rethinking of techniques, materials and treatments in order to provide a quality restoration to the patient.

Therefore, objective of the present study was to evaluate the in vitro microtensile adhesive strength when using flowable resin composite, preheated resin composite and dual self-adhesive resin cement as dentin luting agents.

MATERIALS AND METHODS

BIOETHICAL CONSIDERATIONS

This research respected the bioethical principles for medical research with human beings of the Declaration of Helsinki. Likewise, it was approved by the Ethics and Research Committee of the Faculty of Stomatology of the Universidad Privada San Juan Bautista with official letter No. 436-2021- CIEI-UPSJB. The teeth obtained for the present investigation were donated by the patients, with prior informed consent.

TYPE OF STUDY AND DELIMITATION

This experimental in vitro, cross-sectional and analytical study was carried out at Stomatology School of the Universidad Privada San Juan Bautista and at the High Technology Laboratory Certificate (ISO/IEC Standard: 17025), Lima - Peru; from July to October 2021. This study considered the CRIS Guidelines (Checklist for Reporting In-vitro Studies).[21]

SAMPLE CALCULATION AND SELECTION

30 sample units were distributed in three groups under a completely randomized block design without replacement (n = 10), and were calculated based on data obtained in a previous pilot study where mean comparison formula was applied considering a significance level (α) = 0.05, a statistical power (1-β) = 0.80 with variances S12 = 0.41 and S22 = 1.56, and a mean difference equal to 1.3 Mpa. The experimental groups, according to luting agents employed were:

  • Group 1: RelyX™U200 Dual Self-Adhesive Resinous Cement (3M ESPE, St. Paul, MN, USA)

  • Group 2: Filtek ™ Z250 XT- Resin composite preheated to 70° (3M ESPE, St. Paul, MN, USA).

  • Group 3: Filtek Flow ™ Z350XT Flowable resin composite (3M ESPE, St. Paul, MN, USA).

STUDY VARIABLES

Variables included in the present study were: type of luting agent and bond strength.

SAMPLE CHARACTERISTICS AND PREPARATION

Teeth were extracted during the last 3 months prior to experiment, removing remains of soft tissue or bacterial plaque with a dental ultrasonic scaler (DTE D5 LED, Woodpecker, Guilin, Guangxi, China). They were then stored in 0.9% sodium hypochlorite solution. Subsequently, they were divided into three groups to cut the occlusal third with a rotary tool (DREMEL® 300 Series, Mt. Prospect, Illinois, U.S) and a low-speed water-cooled diamond cutting disc. In addition, a standard mold was made to produce 6 x 6 mm resin blocks with Filtek™ Z250 XT resin composite. Prior to cementation, all resin blocks were micro-sandblasted (MicroJato, Bio-art, Sao Carlos, SP, Brazil) for 15 seconds. Cementation was then performed according to 3 experimental groups: [Figures 1 and 2]:

Figure 1.

Figure 1

Materials used as luting agents

Figure 2.

Figure 2

A: Dual RelyX™U200 Self-Adhesive Resin Cement Preparation. B: Z250XT resin composite preheating. C: Placement of Z350XT Flowable resin composite. D: Light curing of samples with third generation LED curing lamp (Valo - Ultradent, South Jordan, UT, USA)

  • -

    Group 1: Dual RelyX™U200 Self-Adhesive Resin Cement. It was cemented according to manufacturer’s instructions. Surface was cleaned with pumice stone and resin cement was placed on the resin block. The resin cement was set on the surface exerting pressure to eliminate the excess with the help of a microbrush and then light cured with an third generation LED lamp (Valo - Ultradent, South Jordan, UT, USA) with an intensity of 1200 mW/cm2 for 20 seconds.

  • -

    Group 2: Filtek™ Z250 XT- resin composite preheated to 70°. A 37% acid etch with Scotchbond™ Etchant™ was performed (3M ESPE, Maplewood, Minnesota, USA), for 15 seconds, then washed with water for 10 seconds and dried the excess moisture with cotton. Then, a single layer of AdperTM Single Bond 2 adhesive (3M ESPE, Maplewood, Minnesota, U.S.) was applied on sample, evaporating the solvent with gentle air flow for 3 seconds and light cured with an LED lamp at an intensity of 1200 mW/cm2 for 20 seconds. Resin composite was preheated in an AR Heater (Zhengzhou, Henan, China) at 70°C [Figure 3] for 10 minutes and then cemented. The material was placed in the resin block, settled on surface exerting pressure to eliminate excess, which was removed with microbrush, and light cured with LED lamp at an intensity of 1200 mW/cm2 for 20 seconds.

  • -

    Grupo 3: Filtek Flow™ Z350XT Flowable Resin Composite. A 37% acid etch was performed with Scotchbond™ Etchant for 15 seconds, then washed with water for 10 seconds and dried the excess moisture with cotton. Then a single layer of AdperTM Single Bond 2 adhesive was applied on sample, evaporating the solvent with gentle air flow for 3 seconds and light cured with an LED lamp at an intensity of 1200 mW/cm2 for 20 seconds. Then, the material was placed in the resin block, settled on surface exerting pressure to eliminate the excess, which was removed with microbrush, and light cured with LED lamp at an intensity of 1200 mW/cm2 for 20 seconds.

Figure 3.

Figure 3

A: Rear side of heater with temperature indicator. B: Front side of heater (red color indicates 70°C)

Subsequently, 5000 thermocycles between 5+/-2°C and 55+/-2°C were applied to all study samples. For better handling, teeth were placed on an acrylic base to obtain microbars. Horizontal and vertical cuts were made using a low speed water-cooled diamond cutting disc, changing the disc every 5 cuts. The dimensions of microbars were 1 mm × 1 mm × 8 mm[22] obtaining 10 bars per group [Figure 4]. Measurements were made with a digital vernier caliper (Mitutoyo, Kawasaki, Kanagawa, Japan).

Figure 4.

Figure 4

A: Cutting of microbars. B: Measurement of microbars

MICROTENSILE TEST

Once the 30 samples were obtained, they were placed in saline solution for 24 hours at room temperature prior to microtensile testing. The tests were performed using a digital universal testing machine (CMT-5L Liangong, Shandong, China) with a software digital (Smart Test) at a crosshead speed of 0.5 mm/min [Figure 5]. The bond strength values obtained after the test were analyzed in Megapascals (MPa).

Figure 5.

Figure 5

A: Samples prior to microtensile. B: Microtensile Universal Testing Machine. C: Microtensile test. D: Samples after microtensile

STATISTICAL ANALYSIS

The data collected were entered in a Microsoft Excel 2019® file and subsequently imported for statistical analysis by the SPSS program (Statistical Package for the Social Sciences Inc. IBM, NY, USA) version 24.0. For descriptive analysis, measures of central tendency such mean and measures of dispersion such standard deviation were used. For comparative analysis, the Shapiro Wilk normality test and Levene’s homoscedasticity test were previously performed. With the results, the statistical decision to use the nonparametric Kruskall-Wallis test with the Bonferroni post hoc test was made, considering a significance value of 5% (P < 0.05), with a type I error.

RESULTS

The preheated resin composite as dentin luting agent presented higher values of microtensile bond strength with a mean of 6.08 ± 0.66 Mpa, while the dual self-adhesive cement presented the lowest values with a mean of 2.82 ± 1.26 Mpa. [Table 1 and Graph 1].

Table 1.

Microtensile bond strength (Mpa), according to luting agent

Luting agent n Median Mean SD SE 95% CI Min Max
LL UL
Dual self-bonding cement 10 2.46 2.82 1.26 0.40 1.92 3.72 1.37 4.98
Preheated Resin 10 5.87 6.08 0.66 0.21 5.61 6.56 5.42 7.55
Flowable Resin 10 4.64 5.25 2.60 0.82 3.39 7.11 2.90 10.54

Mpa: Megapascals, n: sample, SD: Standard Deviation, SE: Standard Error, Ll: Lower Limit, UL: Upper Limit, CI: Confidence Interval, Min: Minimum, Max: Maximum

Graph 1.

Graph 1

Distribution of the microtensile bond strength values, according to the dentin luting agent

When comparing the microtensile bond strength, it was noticed that there were significant differences (P < 0.001) between the three dentin luting agents, with the preheated resin composite obtaining less dispersed values (RIQ = 0.99) [Table 2].

Table 2.

Comparison of microtensile bond strength (Mpa) between the three luting agents

Luting agent n Median IQR p-value p-value p-value
Dual self-bonding cement 10 2.46 2.16 0.113 0.008b <0.001c
Preheated Resin 10 5.87 0.99 0.106
Flowable Resin 10 4.64 3.75 0.038a

n: sample, IQR: interquartile range; aShapiro-Wilk normality test, no normal distribution (p<0.05); bLevene homoscedasticity test, non-homogeneous variances (p<0.05); cKruskal-Wallis test, significant differences (p<0.05)

As dentin luting agent, preheated resin composite presented significantly higher microtensile bond strength in comparison to dual self-adhesive cement (P < 0.001). While the flowable resin composite did not present significant differences with the dual self-adhesive cement (P = 0.054) and the preheated resin (P = 0.329), respectively [Table 3 and Graph 2].

Table 3.

Pairwise comparison of the microtensile bond strength variable, according to luting agent

Luting Agent Flowable Resin Preheated Resin
Dual self-bonding cement p = 0.054 p< 0.001*
Preheated Resin p = 0.329 -

*Based on Bonferroni adjustment test, significant differences (p<0.05)

Graph 2.

Graph 2

Statistical comparisons between luting agents

DISCUSSION

Bonding to dentin continues to be a challenge, compared to enamel, due to its hydrophilic nature. In this sense, in order to achieve success when cementing an indirect restoration, it is necessary to use materials that present greater bonding strength to dentin.[18,19,23] Currently there are different adhesive materials and different application techniques. Therefore, the present study aimed to evaluate the microtensile bond strength in vitro, using flowable resin composite, preheated resin composite and dual self-adhesive resin cement, as a dentin luting agent. It was obtained that the preheated resin composite resin presented significantly higher values in microtensile bond strength with respect to the dual self-adhesive cement, and higher values than the flowable resin composite, although not significantly. These results were in agreement with those reported by Goulart et al[24] and Ugarte et al.[25]

However, this disagrees with Görüs,[7] who mentions that strength values of adhesive cements decrease after preheating, which could be due to the composition of the material used, since it contained fiber inside the filler and preheating could have caused its structural rupture, reducing the bonding values. Likewise, Morais et al[26] have reported that effectiveness of preheating depends on the resinous product used. It has also been reported that preheating of resinous composites decreases their viscosity, reduces film thickness and improves marginal sealing. In addition, it has been reported that there is between 10 and 15 seconds of ideal working time when the temperature and viscosity in the resin composite are still optimal, so it should be applied quickly, knowing that after removing it from the heating equipment, its temperature decreases about 50% in two minutes.[7,14,25]

Urcuyo et al. mentioned that preheating the resin to 60°C increases the conversion of monomers, originating an increase also in molecular mobility. With higher conversion there is greater crosslinking and the free space of polymers is reduced, improving their mechanical properties.[27] This allows to deduce that, if the temperature increases, the mechanical properties as well. Some reports state that increasing the temperature of resin composite between 54° and 68°C would not damage the pulp chamber,[27] since preheating to 68°C increases the pulp temperature between 0.8 to 1.2°C. To cause pulp damage the temperature should be increased by 5.5°C.[28,29] For this reason, in the present study it was decided to preheat resin to 70°C.

As for dual self-adhesive cement resin (RelyX U200), it presents phosphoric acid ester and modified multifunctional methacrylate monomers, which have high affinity for the minerals in substrate, which penetrate the dentin creating micromechanical retention and chemical bonding with the calcium ions of hydroxyapatite.[30,31] This suggest that this material would present a higher microtensile bond strength. However, Bulut et al. mentioned that this composite would contain phosphoric acid with a very low pH which would not help the chemical bonding with dentin, resulting in inadequate demineralization and weak formation of the hybrid layer,[32] which would explain the low bond strength obtained in the present study. On the other hand, the hydrophilic monomers present in self-adhesive materials, compared to conventional composites, present a greater tendency to water absorption, which leads to swelling of the matrix and consequent rupture of its polymeric chains. These interactions may weaken the mechanical properties of self-adhesive composites, resulting in significantly reduced bond strength.[33] This further reinforces the poor bond strength obtained.

On the other hand, flowable resin composite showed superior bond strength to dual self-adhesive cement, which may be due to fact that it was placed after acid etching and adhesive application. Acid etching would demineralize the smear layer, exposing the collagen fibers of superficially demineralized dentin, causing increased micromechanical interlocking of the bonding agent and resin inside the dentin surface..[34]

It should be emphasized that compact resin was used to make the luting blocks because it is reported to have less light attenuation compared to other materials. It has also been reported that light attenuation causes reduction in the conversion degree of luting agent and is also associated with reduced mechanical properties.[24] Therefore, in the present study, the use of nanohybrid resin composite was chosen to prevent light attenuation from affecting the mechanical properties of materials tested. Also, the application of 5000 thermocycles between 5+/-2°C and 55+/-2°C to all experimental units was justified in order to simulate the temperature variation that occurs in the oral cavity equivalent to half a year of clinical aging, considering that thermal fluctuations can cause microcracks across the resin interface with the luting agents and this could influence the microtensile bond strength.[35,36,37]

Results of the present study suggest an alternative for cementation of indirect restorations taking into account the microtensile bond strength of three adhesive systems, allowing to suggest the use of a preheated resin as luting material to ensure greater bond strength to dental substrate. However, these results should be taken with caution, since, as a limitation of this study, it is recognized that results obtained in this in vitro study cannot be extrapolated to clinical field. For this reason, it is advisable to conduct randomized clinical trials related to the stated objective. In addition, more comparative studies are needed between the three luting agents used, with a larger sample to ensure the performance of parametric tests and to be able to make statistical inference. Furthermore, it is recommended in future studies to use composites with different filler characteristics, since this could influence the reaction of resin to preheating and therefore its mechanical properties. Likewise, it is suggested to control the variable “time elapsed when placing material”, as well as to study the effect of resin preheating on intrapulp temperature.

CONCLUSION

In summary, with the limitations presented by this in vitro study, it can be concluded that the microtensile bond strength in dentin was significantly higher when using a preheated resin composite at 70°C as luting agent compared to dual self-adhesive cement. However, the preheated resin composite showed similar microtensile bond strength compared to flowable resin composite.

FINANCIAL SUPPORT AND SPONSORSHIP

Nil.

CONFLICTS OF INTEREST

None to declare.

AUTHORS CONTRIBUTIONS

They conceived the research idea (LCCR), elaborated the manuscript (LCCR, MILC, LACG, CFCR), collected, tabulated the information (LCCR, CLG), carried out the bibliographic search (MILC, CLG), interpreted the statistical results (CFCR, MAV), helped in the development of the discussion (LCCR, HCC, MAV, CFCR), performed the critical review of the manuscript (HCC, LACG, CFCR). All authors approved the final version of the manuscript.

ETHICAL POLICY AND INSTITUTIONAL REVIEW BOARD STATEMENT

This research respected the bioethical principles for medical research with human beings of the Declaration of Helsinki. Likewise, it was approved by the Ethics and Research Committee of the Faculty of Stomatology of the Universidad Privada San Juan Bautista with official letter No. 436-2021-CIEI-UPSJB.

PATIENT DECLARATION OF CONSENT

Not applicable.

DATA AVAILABILITY STATEMENT

The data that support the study results are available from the author (Ms. Leonor Castro-Ramirez, e-mail: leonor.castro@upsjb.edu.pe) on request.

ACKNOWLEDGEMENTS

We thank the team of the “Biomaterials” research line of the School of Stomatology of the San Juan Bautista Private University, Lima e Ica, Peru, for their constant support in the preparation of this manuscript.

REFERENCES

  • 1.Azeem RA, Sureshbabu NM. Clinical performance of direct versus indirect composite restorations in posterior teeth: A systematic review. J Conserv Dent. 2018;21:2–9. doi: 10.4103/JCD.JCD_213_16. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Cayo C, Llancari L, Mendoza R, Cervantes L. Marginal filling and adhesive resistance of bulk fill resin applying 18% EDTA gel compared with 37% phosphoric acid gel in vitro dental conditioning. J Oral Res. 2019;8:228–35. https://doi.org/10.17126/joralres.2019.034. [Google Scholar]
  • 3.Derchi G, Marchio V, Borgia V, Özcan M, Giuca MR, Barone A. Twelve-year longitudinal clinical evaluation of bonded indirect composite resin inlays. Quintessence Int. 2019;50:448–54. doi: 10.3290/j.qi.a42477. [DOI] [PubMed] [Google Scholar]
  • 4.Soares CJ, Faria-E-Silva AL, Rodrigues MP, Vilela ABF, Pfeifer CS, Tantbirojn D, et al. Polymerization shrinkage stress of composite resins and resin cements - what do we need to know? Braz Oral Res. 2017;31:e62. doi: 10.1590/1807-3107BOR-2017.vol31.0062. [DOI] [PubMed] [Google Scholar]
  • 5.Ramírez-Vargas GG, Medina y Mendoza JE, Aliaga-Mariñas AS, Ladera-Castañeda MI, Cervantes-Ganoza LA, Cayo-Rojas CF. Effect of polishing on the surface microhardness of nanohybrid composite resins subjected to 35% hydrogen peroxide: An in vitro study. J Int Soc Prevent Communit Dent. 2021;11:216–21. doi: 10.4103/jispcd.JISPCD_9_21. doi: 10.4103/jispcd.JISPCD_9_21. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Manso AP, Carvalho RM. Dental cements for luting and bonding restorations: Self-adhesive resin cements. Dent Clin North Am. 2017;61:821–34. doi: 10.1016/j.cden.2017.06.006. [DOI] [PubMed] [Google Scholar]
  • 7.Görüş Z. Examination of the effect of preheating process on microtensile bond strength in the cementation of indirect restorations. International Dental Research. 2018;8:15–21. https://doi.org/10.5577/intdentres.2018.vol8.no1.3. [Google Scholar]
  • 8.Pouyanfar H, Tabaii ES, Aghazadeh S, Nobari SPTN, Imani MM. Microtensile bond strength of composite to enamel using universal adhesive with/without acid etching compared to etch and rinse and self-etch bonding agents. Open Access Maced J Med Sci. 2018;6:2186–92. doi: 10.3889/oamjms.2018.427. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Tomaselli LO, Oliveira DCRS, Favarão J, Silva AFD, Pires-de-Souza FCP, Geraldeli S, et al. Influence of pre-heating regular resin composites and flowable composites on luting ceramic veneers with different thicknesses. Braz Dent J. 2019;30:459–66. doi: 10.1590/0103-6440201902513. [DOI] [PubMed] [Google Scholar]
  • 10.Bragança G, Mazão J, Versluis A, Soares C. Effect of luting materials, presence of tooth preparation, and functional loading on stress distribution on ceramic laminate veneers: A finite element analysis. J Prosthet Dent. 2020;125:778–87. doi: 10.1016/j.prosdent.2020.02.005. doi: 10.1016/j.prosdent.2020.02.005. [DOI] [PubMed] [Google Scholar]
  • 11.Pratap B, Gupta RK, Bhardwaj B, Nag M. Resin based restorative dental materials: Characteristics and future perspectives. Jpn Dent Sci Rev. 2019;55:126–38. doi: 10.1016/j.jdsr.2019.09.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Kusuma Yulianto HD, Rinastiti M, Cune MS, de Haan-Visser W, Atema-Smit J, Busscher HJ, et al. Biofilm composition and composite degradation during intra-oral wear. Dent Mater. 2019;35:740–50. doi: 10.1016/j.dental.2019.02.024. [DOI] [PubMed] [Google Scholar]
  • 13.Magne P, Razaghy M, Carvalho MA, Soares LM. Luting of inlays, onlays, and overlays with preheated restorative composite resin does not prevent seating accuracy. Int J Esthet Dent. 2018;13:318–32. [PubMed] [Google Scholar]
  • 14.Marcondes RL, Lima VP, Barbon FJ, Isolan CP, Carvalho MA, Salvador MV, et al. Viscosity and thermal kinetics of 10 preheated restorative resin composites and effect of ultrasound energy on film thickness. Dent Mater. 2020;36:1356–64. doi: 10.1016/j.dental.2020.08.004. [DOI] [PubMed] [Google Scholar]
  • 15.Manríquez C, Tranamil F, Vargas P. Comparison of thickness and homogeneity of thecementationlayer in indirectveneers, madewith fluidresin vs. light-cure resincement: In vitro study. Odont Vital. 2019;30:65–72. Available from: http://www.scielo.sa.cr/scielo.php?script=sci_arttext&pid=S1659-07752019000100065&lng=en . [Google Scholar]
  • 16.Baroudi K, Rodrigues JC. Flowable resin composites: A systematic review and clinical considerations. J Clin Diagn Res. 2015;9:ZE18–24. doi: 10.7860/JCDR/2015/12294.6129. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Prieto LT, Pimenta de Araújo CT, Araujo Pierote JJ, Salles de Oliveira DCR, Coppini EK, Sartini Paulillo LAM. Evaluation of degree of conversion and the effect of thermal aging on the color stability of resin cements and flowable composite. J Conserv Dent. 2018;21:47–51. doi: 10.4103/JCD.JCD_128_17. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Kumari RV, Poluri RK, Nagaraj H, Siddaruju K. Comparative evaluation of bond strength of dual-cured resin cements: An in-vitro study. J Int Oral Health. 2015;7:43–7. [PMC free article] [PubMed] [Google Scholar]
  • 19.Sano H, Chowdhury AFMA, Saikaew P, Matsumoto M, Hoshika S, Yamauti M. The microtensile bond strength test: Its historical background and application to bond testing. JPN Dent Sci Rev. 2020;56:24–31. doi: 10.1016/j.jdsr.2019.10.001. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Maaßen M, Wille S, Kern M. Bond strength of adhesive luting systems to human dentin and their durability. J Prosthet Dent. 2021;125:182–8. doi: 10.1016/j.prosdent.2019.07.012. [DOI] [PubMed] [Google Scholar]
  • 21.Krithikadatta J, Gopikrishna V, Datta M. Cris guidelines (checklist for reporting in-vitro studies): A concept note on the need for standardized guidelines for improving quality and transparency in reporting in-vitro studies in experimental dental research. J Conserv Dent. 2014;17:301–4. doi: 10.4103/0972-0707.136338. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Yuan H, Li M, Guo B, Gao Y, Liu H, Li J. Evaluation of microtensile bond strength and microleakage of a self-adhering flowable composite. J Adhes Dent. 2015;17:535–43. doi: 10.3290/j.jad.a35253. [DOI] [PubMed] [Google Scholar]
  • 23.van den Breemer C, Özcan M, Cune MS, Ayres AA, Van Meerbeek B, Gresnigt M. Effect of immediate dentin sealing and surface conditioning on the microtensile bond strength of resin-based composite to dentin. Oper Dent. 2019;44:E289–98. doi: 10.2341/18-052-L. [DOI] [PubMed] [Google Scholar]
  • 24.Goulart M, Borges Veleda B, Damin D, Bovi Ambrosano GM, Coelho de Souza FH, Erhardt MCG. Preheated composite resin used as a luting agent for indirect restorations: Effects on bond strength and resin-dentin interfaces. Int J Esthet Dent. 2018;13:86–97. [PubMed] [Google Scholar]
  • 25.Ugarte F, Sanchez M. Preheated Filtek Z250 XT resin as a luting agent in indirect restorations. Rev Cubana Estomatol. 2021;58:e3283. Available from: http://www.revestomatologia.sld.cu/index.php/est/article/view/3283 . [Google Scholar]
  • 26.Morais A, Santos AR, Giannini M, Reis AF, Rodrigues JA, Arrais CA. Effect of pre-heated dual-cured resin cements on the bond strength of indirect restorations to dentin. Braz Oral Res. 2012;26:170–6. doi: 10.1590/s1806-83242012000200014. [DOI] [PubMed] [Google Scholar]
  • 27.Urcuyo M, Escobar D, Pozos A, Flores J, Romo G, Ortiz M. Evaluation of the bond strength and marginal seal of indirect restorations of composites bonded with preheating resin. Eur J Dent. 2020;14:644–50. doi: 10.1055/s-0040-1716630. doi: 10.1055/s-0040-1716630. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Lohbauer U, Zinelis S, Rahiotis C, Petschelt A, Eliades G. The effect of resin composite pre-heating on monomer conversion and polymerization shrinkage. Dent Mater. 2009;25:514–9. doi: 10.1016/j.dental.2008.10.006. [DOI] [PubMed] [Google Scholar]
  • 29.Karacan AO, Ozyurt P. Effect of preheated bulk-fill composite temperature on intrapulpal temperature increase in vitro. J Esthet Restor Dent. 2019;31:583–8. doi: 10.1111/jerd.12503. [DOI] [PubMed] [Google Scholar]
  • 30.Lima D, Linhares T, Lima S, Carvalho E, Loguercio A, Bauer J, Carvalho CN. Effect of sonic application of self-adhesive resin cements on push-out bond strength of glass fiber posts to root dentin. Materials (Basel) 2019;12:1930. doi: 10.3390/ma12121930. doi: 10.3390/ma12121930. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Velo MMAC, Nascimento TRL, Scotti CK, Bombonatti JFS, Furuse AY, Silva VD, et al. Improved mechanical performance of self-adhesive resin cement filled with hybrid nanofibers-embedded with niobium pentoxide. Dent Mater. 2019;35:e272–85. doi: 10.1016/j.dental.2019.08.102. [DOI] [PubMed] [Google Scholar]
  • 32.Bulut NB, Evlioğlu G, Röhlig BG, Çelakıl T. Effect of dentin pretreatment on shear bond strength of three resin-based luting cements. Eur Oral Res. 2018;52:82–8. doi: 10.26650/eor.2018.449. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Peterson J, Rizk M, Hoch M, Wiegand A. Bonding performance of self-adhesive flowable composites to enamel, dentin and a nano-hybrid composite. Odontology. 2018;106:171–80. doi: 10.1007/s10266-017-0324-3. [DOI] [PubMed] [Google Scholar]
  • 34.Abdelraouf RM, Mohammed M, Abdelgawad F. Evaluation of shear-bond-strength of dental self-adhering flowable resin-composite versus total-etch one to enamel and dentin surfaces: An in-vitro study. Open Access Maced J Med Sci. 2019;7:2162–6. doi: 10.3889/oamjms.2019.579. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Chao X, Ying H, Xin-Yi Z, Zhong-Yi W, Hui-Ming H. Microtensile bond strength of one- and two-step self-etching adhesives on sclerotic dentin: The effects of thermocycling. Oper Dent. 2010;35:547–55. doi: 10.2341/10-025-L. doi: 10.2341 / 10-025-L. [DOI] [PubMed] [Google Scholar]
  • 36.Cayo C, Carrillo A. Sellado marginal aplicando hipoclorito de sodio versus ácido fosfórico Como acondicionador dental. Rev Cubana Estomatol. 2020;57:e2872. Available at: http://www.revestomatologia.sld.cu/index.php/est/article/view/2872 . [Google Scholar]
  • 37.Zakavi F, Johar N, Moalemnia M, Rakhshan V. Effects of at-home and in-office bleaching and three composite types (hybrid, microhybrid, and nanofilled) on repair shear bond strength of aged composites: A preliminary study. Dent Res J (Isfahan) 2021;18:1–9. Available from: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8428288/ [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The data that support the study results are available from the author (Ms. Leonor Castro-Ramirez, e-mail: leonor.castro@upsjb.edu.pe) on request.


Articles from Journal of International Society of Preventive & Community Dentistry are provided here courtesy of Wolters Kluwer -- Medknow Publications

RESOURCES