Skip to main content
Surgical Neurology International logoLink to Surgical Neurology International
. 2024 Mar 29;15:111. doi: 10.25259/SNI_147_2024

Investigation of long lateral mass screw insertion torque

Seiya Watanabe 1,*, Kazuo Nakanishi 1, Yoshihisa Sugimoto 1, Kazuya Uchino 1, Hideaki Iba 1
PMCID: PMC11021086  PMID: 38628514

Abstract

Background:

Here, we assessed a new trajectory and insertion torque for the placement of a long lateral mass screw (LLMS) that offers stronger posterior fixation versus a shorter lateral mass screw (LMS) in the posterior cervical spine. We report a short technical note of the insertion torque of LLMS.

Methods:

The insertion trajectory/torque was evaluated in 30 patients (10 males and 20 females) undergoing posterior cervical LLMS fusions (2021–2023). Patients averaged 65 years of age. Pathology included eight cervical spine injuries, ten cord injuries, four dislocations/fractures, and eight other entities. Variables studied included the length of the LLMS inserted from C3–7, screw deviation rates, insertion torque, and adverse events.

Results:

A total of 146 screws were inserted: 11 pedicle screws (PSs) and 135 LLMS. The average insertion torque was 105.9 cNm for PS and 64.9 cNm for LLMS. As the screw lengthened by 1 mm, the insertion torque increased by approximately 4.4 cNm.

Conclusion:

Here, we documented that the insertion torque of LLMS was 66.1 cNm, greater than the 51.0 cNm for LMS, which should provide stronger posterior cervical fixation.

Keywords: Cervical, Insertion torque, Lateral mass screw


graphic file with name SNI-15-111-inline001.jpg

INTRODUCTION

Here, we report a new trajectory and technique for the placement of a long lateral mass screw (LLMS) versus a Lateral mass screw (LMS) that should facilitate stronger posterior cervical spine fusion.[4] We report a short technical note of the insertion torque of LLMS.

MATERIALS AND METHODS

We evaluate the trajectory and insertion torque for placing LLMS in 30 patients (10 males and 20 females) undergoing posterior cervical spine fusion (2021–2023); patients averaged 65 years old. Pathologies addressed included eight cases of cervical spine injuries, ten cord injuries, four dislocations/fractures, and eight other cases. Variables studied included screw length, insertion torque, screw deviation rate, and adverse events.

RESULTS

A total of 146 screws were inserted’ 11 pedicle screws (PS) and 135 LLMS. The average screw length was 24.7 ± 1.4 mm (22–26 mm) for PS and 22.0 ± 2.5 mm (18– 30 mm) for LLMS (P = 0.74) [Figure 1]. The average insertion torque was 105.9 cNm for PS and 64.9 cNm for LLMS [P = 0.04] [Figure 2]. The insertion torque increased with longer screws with a positive correlation [Figure 3]. The rate of Grade 2 or higher deviations in screw was 9.1% (1/11) for PS and 3.7% (5/135) for LLMS [Figures 4 and 5]. There were no adverse events [Table 1].

Figure 1:

Figure 1:

Screw length (mm). LLMS: Long Lateral mass screw, PS: Pedicle screw

Figure 2:

Figure 2:

Insertion torque (cNm). LLMS: Long Lateral mass screw, PS: Pedicle screw

Figure 3:

Figure 3:

As the screw lengthened by 1 mm, the insertion torque increased by approximately 4.4 cNm.

Figure 4:

Figure 4:

Deviation rate (%). LLMS: Long Lateral mass screw, PS: Pedicle screw.

Figure 5:

Figure 5:

(a) G0: No deviation, (b) G1 Screw diameter ½<, (c) G2 Screw diameter ½≧, and (d) G3 all screw diameter.

Table 1:

LLMS versus PS results. PS LLMS

graphic file with name SNI-15-111-t001.jpg

DISCUSSION

PS has a good posterior cervical fixation, but if it deviates, there is a risk of major complications (i.e., range 1.2–18.2%) even with navigation.[3] Our LLMS deviation rate was 35 cases (6/183 screws or 3.2%); none resulted in a vertebral artery or spinal cord injury. The screw length we utilized for LLMS was 21 ± 2.7 mm, longer than that of the LMS system (Roy-Camille: 14–15 mm, Mager l: 15–16 mm).[1-3] In this study, the 4.5 mm diameter screws were used for PS and 3.5 mm diameter screws for LLMS. The average insertion torque of PS was 105.9 cNm, while for LLMS, it was 64.9 cNm. The strength of LLMS screws was about 60% that of PS, suggesting that the insertion torque of LLMS tends to be higher despite the use of a smaller diameter screw. Here, using a 1 mm longer screw, the insertion torque increased by approximately 4.4 cNm.

CONCLUSION

We concluded that the insertion torque of LLMS was higher than that of LMS and that LLMS provides stronger posterior cervical fixation.

Footnotes

How to cite this article: Watanabe S, Nakanishi K, Sugimoto Y, Uchino K, Iba H. Investigation of long lateral mass screw insertion torque. Surg Neurol Int. 2024;15:111. doi: 10.25259/SNI_147_2024

Contributor Information

Seiya Watanabe, Email: seiya-w@med.kawasaki-m.ac.jp.

Kazuo Nakanishi, Email: nakanishikazuo60@gmail.com.

Yoshihisa Sugimoto, Email: sugi.ort@gmail.com.

Kazuya Uchino, Email: kazuya_u@med.kawasaki-m.ac.jp.

Hideaki Iba, Email: i-hideaki@med.kawasaki-m.ac.jp.

Ethical approval

The research/study approved by the Institutional Review Board at Kawasaki medical school, number 3782, dated 2019/12/19.

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

Use of artificial intelligence (AI)-assisted technology for manuscript preparation

The authors confirm that they have used artificial intelligence (AI)-assisted technology for assisting in the writing or editing of the manuscript or image creations.

Disclaimer

The views and opinions expressed in this article are those of the authors and do not necessarily reflect the official policy or position of the Journal or its management. The information contained in this article should not be considered to be medical advice; patients should consult their own physicians for advice as to their specific medical needs.

REFERENCES

  • 1.Magerl F, Seeman PF, Grob D. The cervical spine 1. New York: Springer Verlag; 1987. Stable dorsal fusion of cervical spine (C2-T1) using hook plates. [Google Scholar]
  • 2.Roy-Camille R, Saillant G, Laville C, Benazet JP. Treatment of lower cervical spinal injuries-C3 to C7. Spine (Phila Pa 1976) 1992;17:S442–6. doi: 10.1097/00007632-199210001-00017. [DOI] [PubMed] [Google Scholar]
  • 3.Shimokawa N, Sato H, Shirosaka K, Nakagawa C, Takami T. Accuracy of cervical pedicle screw placement with a navigation system. Spinal Surg. 2017;31:59–66. [Google Scholar]
  • 4.Watanabe S, Nakanishi K, Uchino K. Usefulness of the long lateral mass screw. J Spine Res. 2021;12:16–22. [Google Scholar]

Articles from Surgical Neurology International are provided here courtesy of Scientific Scholar

RESOURCES