Skip to main content
NIHPA Author Manuscripts logoLink to NIHPA Author Manuscripts
. Author manuscript; available in PMC: 2024 Apr 30.
Published in final edited form as: Lancet Gastroenterol Hepatol. 2020 May 14;5(8):715–717. doi: 10.1016/S2468-1253(20)30123-0

The future of tumour-specific fluorescence-guided surgery for pancreatic cancer

Thinzar M Lwin 1, Robert M Hoffman 1, Michael Bouvet 1
PMCID: PMC11057912  NIHMSID: NIHMS1988373  PMID: 32416765

A crucial issue in the surgical treatment of patients with pancreatic ductal adenocarcinoma is the absence of direct, real-time, intraoperative visualisation of the lesion and its metastases. An unacceptably high number of surgeries with curative intent for localised pancreatic ductal adenocarcinoma result in early locoregional recurrence, suggesting a weakness in our ability to completely remove the tumour at its resection bed and to recognise radiographically occult metastatic disease. There is a need for an agent to enhance the ability of surgeons to assess the tumour and metastases (if present), directly and in real-time. The ideal agent should be safe and cost-effective, with rapid pharmacokinetics and a high sensitivity and specificity to the tumour, lymph nodes, and metastases while sparing non-cancerous tissue.1,2

Contrast enhancement using near-infrared fluorescent dyes can provide surgeons with additional information. Indocyanine green is a near-infrared dye used in perfusion assessment, but it has been studied for its ability to preferentially accumulate in tumours due to disorganised tumour neovaculature, impaired lymphatic drainage, and increased permeability. This is called the enhanced permeability and retention effect. Indocyanine green was used for fluorescence-guided surgery for pancreatic ductal adenocarcinoma in an initial cohort of 20 patients.3 However, indocyanine green is non-specific; moreover, it would be desirable to link the fluorophore to a molecule that binds to the tumour directly. Probes evaluated for tumour-specificity are commonly antibodies, but fragmented antibodies, single-domain antibodies (nanobodies), peptides, and antibody mimetics are also under consideration.4

Only two previous clinical trials of tumour-specific fluorescent antibodies for fluorescence-guided surgery for pancreatic cancer exist. The first study assessed cetuximab, a chimeric anti-EGFR antibody linked to IRDye800CW (NCT02736578). The trial was stopped because of adverse infusion reactions. The second study,5 a phase 1 trial of 12 patients undergoing surgery for pancreatic ductal adenocarcinoma, used a chimeric antihuman carcinoembryonic antigen antibody linked to a 700 nm fluorophore (NCT02973672). Carcinoembryonic antigen is overexpressed in 71–98% of pancreatic ductal adenocarcinoma.6 In this study, the fluorescent anticarcinoembryonic antigen antibody (SGM-101) showed safety and efficacy.

The cell-surface marker EGFR is a rational target for tumour-specific intraoperative fluorescence imaging because it is overexpressed in up to 69% of patients with pancreatic ductal adenocarcinoma.7 In the study by Lu and colleagues7 in The Lancet Gastroenterology & Hepatology, the authors used a humanised anti-EGFR antibody, panitumumab, linked to an 800 nm fluorophore, IRDye800CW. They report the results of their phase 1 clinical trial of 11 patients who received 25 mg, 50 mg, or 75 mg of panitumumab-IRdye800CW, 2–5 days before surgery. They found that the molecule was safe, with four minor reactions related to the study drug (one grade 2 adverse event and three grade 1 adverse events). The pancreatic tumour was detectable in all dose cohorts. Fluorescence-guided surgery with panitumumab-IRDye800CW was feasible in both an open and laparoscopic setting using existing 800 nm imaging devices for indocyanine green imaging (Novadaq Pinpoint and Spy-PHI [Novadaq, Burnaby, BC, Canada]). Mean fluorescence intensity increased linearly and the tumour-to-background ratio ranged from three to four.

The authors are to be commended for advancing tumour-specific fluorescence-guided surgery using a rational design, with an antibody widely available for therapeutic use, and imaging devices that are already present in operating rooms. However, the study does have some limitations. EGFR expression can be increased in pancreatitis, but Tummers and colleagues8 showed in their work with cetuximab-IRDye800CW in patients with pancreatic ductal adenocarcinoma that there was a statistically significant difference in fluorescence intensity between tissue with pancreatitis and pancreatic ductal adenocarcinoma.8 Of note, five of the ten patients in this cohort received neoadjuvant therapy with a fluorescence signal present at the tumour.8 Lu and colleagues7 did not comment on whether neoadjuvant therapy affects the fluorescence signal because there is a potential for antigenic shift with pretreatment.8 More work is needed in this setting.

The work by Lu and colleagues7 and Hoogstins and colleagues5 heralds the beginning of a new era of direct, tumour-specific fluorescence-guided surgery. As more agents are tested in clinical trials, more information will be needed to determine the optimal fluorescence signal for navigation. A wide array of factors can affect the overall image at the time of surgery. Comparing pharmacokinetics across a wide combination of probes and fluorophores is difficult. Serum shedding of tumour antigen with serum sequestration of fluorescent probes and differential expression of the antigen in the setting of neoadjuvant therapy can further complicate the issue. The sensitivity of imaging devices can additionally affect detection. Acceptable signal thresholds for molecule and imaging devices need to be established. Current preclinical studies with clinically relevant models—such as patient-derived orthotopic xenografts in nude mouse models, which better recapitulate human patterns of metastases compared with subcutaneous mouse models—suggest a bright future for tumour-targeted fluorescence-guided surgery.9,10

Although tumour-specific fluorescence-guided surgery can never replace clinical judgment, this technology has the potential to greatly enhance intraoperative decision making, increase the likelihood of complete surgical resection, and potentially affect patient outcomes. More information will be forthcoming as evidence accumulates and the field of tumour-specific fluorescence-guided surgery matures.

Footnotes

We declare no competing interests.

References

  • 1.Rosenthal EL, Warram JM, de Boer E, et al. Successful translation of fluorescence navigation during oncologic surgery: a consensus report. J Nucl Med Off Publ Soc Nucl Med 2016; 57: 144–50. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Pogue BW, Rosenthal EL, Achilefu S, van Dam GM. Perspective review of what is needed for molecular-specific fluorescence-guided surgery. J Biomed Opt 2018; 23: 1–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Newton AD, Predina JD, Shin MH, et al. Intraoperative near-infrared imaging can identify neoplasms and aid in real-time margin assessment during pancreatic resection. Ann Surg 2019; 270: 12–20. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Lwin TM, Hoffman RM, Bouvet M. The development of fluorescence guided surgery for pancreatic cancer: from bench to clinic. Expert Rev Anticancer Ther 2018; 18: 651–62. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Hoogstins CES, Boogerd LSF, Sibinga Mulder BG, et al. Image-guided surgery in patients with pancreatic cancer: first results of a clinical trial using SGM-101, a novel carcinoembryonic antigen-targeting, near-infrared fluorescent agent. Ann Surg Oncol 2018; 25: 3350–57. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.de Geus SWL, Boogerd LSF, Swijnenburg R-J, et al. Selecting tumor-specific molecular targets in pancreatic adenocarcinoma: paving the way for image-guided pancreatic surgery. Mol Imaging Biol 2016; 18: 807–19. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Lu G, van den Berg NS, Martin BA, et al. Tumour-specific fluorescence-guided surgery for pancreatic cancer using panitumumab-IRDye800CW: a phase 1 single-centre, open-label, single-arm, dose-escalation study. Lancet Gastroenterol Hepatol 2020; published online May 14. 10.1016/S2468-1253(20)30088-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Tummers WS, Miller SE, Teraphongphom NT, et al. Intraoperative pancreatic cancer detection using tumor-specific multimodality molecular imaging. Ann Surg Oncol 2018; 25: 1880–88. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Hoffman RM. Patient-derived orthotopic xenografts: better mimic of metastasis than subcutaneous xenografts. Nat Rev Cancer 2015; 15: 451–52. [DOI] [PubMed] [Google Scholar]
  • 10.Lwin TM, Hoffman RM, Bouvet M. Advantages of patient-derived orthotopic mouse models and genetic reporters for developing fluorescence-guided surgery. J Surg Oncol 2018; 118: 253–64. [DOI] [PMC free article] [PubMed] [Google Scholar]

RESOURCES