Skip to main content
Open Heart logoLink to Open Heart
. 2024 May 8;11(1):e002714. doi: 10.1136/openhrt-2024-002714

Effectiveness, utilisation and cost associated with implantable loop recorders versus external monitors after ischaemic or cryptogenic stroke

Sanket S Dhruva 1,2,3,, Jaime Murillo 4, Omid Ameli 5, Christine E Chaisson 5, Rita F Redberg 1,3,6, Ken Cohen 5
PMCID: PMC11086550  PMID: 38719499

Abstract

Objective

Implantable loop recorders (ILRs) are increasingly used for long-term rhythm monitoring after ischaemic and cryptogenic stroke, with the goal of detecting atrial fibrillation (AF) and subsequent initiation of oral anticoagulation to reduce risk of adverse clinical outcomes. There is a need to determine the effectiveness of different rhythm monitoring strategies in this context.

Methods

We conducted a retrospective cohort analysis of individuals with commercial and Medicare Advantage insurance in Optum Labs Data Warehouse who had incident ischaemic or cryptogenic stroke and no prior cardiovascular implantable electronic device from 1 January 2016 to 30 June 2021. Patients were stratified by rhythm monitoring strategy: ILR, long-term continuous external cardiac monitor (>48 hours to 30 days) or Holter monitor (≤48 hours). The primary outcome was risk-adjusted all-cause mortality at 12 months. Secondary outcomes included new diagnosis of AF and oral anticoagulation, bleeding, and costs.

Results

Among 48 901 patients with ischaemic or cryptogenic stroke, 9235 received an ILR, 29 103 long-term continuous external monitor and 10 563 Holter monitor only. Mean age was 69.9 (SD 11.9) years and 53.5% were female. During the 12-month follow-up period, patients who received ILRs compared with those who received long-term continuous external monitors had a higher odds of new diagnosis of AF and oral anticoagulant initiation (adjusted OR 2.27, 95% CI 2.09 to 2.48). Compared with patients who received long-term continuous external monitors, those who received ILRs had similar 12-month mortality (HR 1.00; 95% CI 0.89 to 1.12), with approximately $13 000 higher costs at baseline (including monitor cost) and $2500 higher costs during 12-month follow-up.

Conclusions

In this large real-world study of patients with ischaemic or cryptogenic stroke, ILR placement resulted in more diagnosis of AF and initiation of oral anticoagulation, but no difference in mortality compared with long-term continuous external monitors.

Keywords: Atrial Fibrillation; STROKE; Outcome Assessment, Health Care


WHAT IS ALREADY KNOWN ON THIS TOPIC.

  • There is increased interest in monitoring patients with ischaemic or cryptogenic stroke for occult atrial fibrillation (AF), with the goal of detecting this arrhythmia and using oral anticoagulation for secondary stroke prevention.

  • Monitoring is increasingly performed using implantable loop recorders (ILRs), but there are no clinical outcomes data to support this practice.

WHAT THIS STUDY ADDS

  • This retrospective cohort study found that use of ILRs after ischaemic or cryptogenic stroke led to greater detection of AF and prescription of oral anticoagulation compared with long-term continuous external monitors (>48 hours to 30 days).

  • However, there was no statistically significant difference in mortality compared with long-term continuous external monitors.

HOW THIS STUDY MIGHT AFFECT RESEARCH, PRACTICE OR POLICY

  • The results of this study indicate an urgent need for randomised clinical trials to study ILRs in secondary stroke prevention.

Introduction

Stroke is the fifth leading cause of death in the USA and a leading cause of long-term disability.1 Cryptogenic strokes, those of uncertain aetiology, comprise 10%–40% of all ischaemic strokes.2 One possible aetiology of cryptogenic stroke is subclinical atrial fibrillation (AF). A new diagnosis of AF after stroke is associated with an increased risk of recurrent stroke,3 and these strokes result in greater morbidity and mortality.4

Accordingly, there has been interest in monitoring for AF among patients with cryptogenic stroke, based on the hypothesis that detection of occult AF and the use of oral anticoagulation could reduce risk of recurrent stroke and subsequent disability and mortality.5 Strategies for AF detection include continuous external monitors and implantable loop recorders (ILRs). The 2021 American Heart Association/American Stroke Association clinical practice guideline for secondary prevention of ischaemic stroke gives a Class 2a recommendation for long-term rhythm monitoring to detect intermittent AF among patients with cryptogenic stroke; this is a moderate recommendation in which benefits are considered to outweigh risks.6 This guideline recommendation is based on three clinical trials with the surrogate endpoint of AF detection as the primary endpoint, not on clinical outcomes such as reduction in recurrent stroke or mortality.7–9

Given that cardiac monitoring after stroke leads to the identification of more AF, it leads to more initiation of oral anticoagulation, especially for long-term monitors such as ILRs.10–12 However, reduction in all-cause mortality has not been demonstrated.10–12 Simultaneously, clinical trial evidence suggests that screening with ILRs among patients with increased risk of stroke (but not necessarily prior stroke) compared with usual care results in threefold higher AF detection and anticoagulant use, but no significant reduction in stroke.13 The additional use of anticoagulation could increase bleeding risk.14

There is a paucity of real-world data in large datasets addressing if long-term cardiac monitoring with ILRs improves clinical outcomes in a secondary stroke prevention setting. Despite the lack of evidence, there has been growth in use of ILRs in recent years, and ILR placement after stroke is the third most common indication for ILR use.15 Accordingly, in this study, we asked: what are outcomes associated with use of ILRs compared with non-invasive rhythm monitoring among patients with recent ischaemic or cryptogenic stroke? Given that ILRs represent a costly, implanted technology, we also sought to understand differences in healthcare expenditures.

Methods

Study design and data source

This retrospective cohort analysis of de-identified administrative claims data used the Optum Labs16 Data Warehouse (OLDW) for commercial and Medicare Advantage enrollees, which includes medical claims, pharmacy claims and enrolment records, and where applicable contains mortality information at month and year. OLDW contains longitudinal health information on enrollees, representing a mixture of ages and geographical regions across the USA. Because data were de-identified in compliance with the Health Insurance Portability and Accountability Act, an Institutional Review Board review or waiver of authorisation was not required.17 This study followed the Strengthening the Reporting of Observational Studies in Epidemiology reporting guidelines. Patients and/or the public were not involved in the design, or conduct, or reporting, or dissemination plans of this research.

Cohort selection

We created a cohort of individuals who received outpatient cardiac rhythm monitoring between 1 January 2016 and 30 June 2021. Patients were stratified into two groups, those with ILR placement and those who did not have an ILR but had either long-term continuous external cardiac monitoring (>48 hours to 30 days) or Holter monitoring (≤48 hours) (online supplemental table 1). Patients were stratified hierarchically based on the earliest date of a claim for an ILR, long-term continuous external cardiac monitor or Holter (and in that order). In other words, those who were classified as Holter could not have either an ILR or long-term continuous external cardiac monitor during their baseline period. Those classified as ILR or long-term continuous external cardiac monitor could have had the lower hierarchy device during baseline (long-term continuous external cardiac monitor or Holter for ILR and only Holter for the long-term continuous external cardiac monitor group).

Supplementary data

openhrt-2024-002714supp001.pdf (321.1KB, pdf)

The date of ILR insertion or earliest claim date for other monitors was the index date. Patients with an index date during an inpatient hospitalisation had the date adjusted to their hospital discharge date. This ensured that for all three groups, device-related inpatient utilisation and cost were consistently captured during the baseline period, which included the index date and 6 months prior to it.

All included patients were required to meet the following criteria during the 6 months prior to placement of the index monitoring device: (1) either cryptogenic or ischaemic stroke diagnosis (online supplemental table 2)15 18; (2) continuous enrolment with medical and pharmacy coverage; (3) no evidence of pacemaker, implantable cardioverter-defibrillator, cardiac resynchronisation therapy, AF ablation, atrioventricular node ablation or left atrial appendage occlusion (online supplemental table 3); (4) no pharmacy claims for warfarin or direct oral anticoagulants (online supplemental table 4); (5) no evidence of complete heart block, haemorrhagic stroke or CHA2DS2-VASc (1 point for congestive heart failure, 1 point for hypertension, 1 point for diabetes mellitus, 2 points for ischaemic stroke/transient ischaemic attack/thromboembolism, 1 point for vascular disease, 1 point for age 65–74 years, 2 points for age ≥75 years and 1 point for female sex) score19 ≤1; and (6) no data anomalies, including missing demographic information (age, sex) or a date of death earlier than index date. All patients were also required to have ≥3 months ILR-free period prior to the index monitoring device (online supplemental table 1).

Outcomes

The primary outcome was all-cause mortality based on month of death from 1 day postindex through 12 months of follow-up. For the analysis of time to month of death, beneficiaries were censored at disenrolment or month of death, whichever occurred earlier.

Secondary outcomes included clinical, safety, healthcare utilisation and cost outcomes. Clinical outcomes were a new diagnosis of AF (online supplemental table 2) and initiation of oral anticoagulants. Although we examined multiple outcomes on the causal path of secondary stroke prevention, including new AF diagnosis and anticoagulation as well as mortality, we did not include recurrent ischaemic or cryptogenic stroke because of a lack of sufficient accuracy of claims diagnoses and potentially differential misclassification.20 Safety outcomes were haemorrhagic stroke, major gastrointestinal bleeding and minor bleeds (online supplemental table 5). Healthcare utilisation outcomes were emergency department (ED) visits, hospitalisations, cumulative number of inpatient days and office visits. Cost outcomes were total costs of care, medical costs, outpatient pharmacy costs and direct medical costs of the monitoring devices; costs are summarised as both total and per member per month (PMPM). All were actual paid costs, which were adjusted to 2020 values using the Consumer Price Index. To assess secondary outcomes, all patients were required to have ≥12 months of continuous medical and pharmacy coverage following the index date; patients who died within the first 12 months were not included in assessment of secondary outcomes. Follow-up was assessed starting the day after the index date.

Covariates

CHA2DS2-VASc score was used for risk adjustment based on comorbidity burden and its association with adverse outcomes among patients with AF.21 Comorbidities were coded using facility and physician medical claims during the 6-month baseline period.

Statistical analysis

Cohort characteristics were summarised overall and for three study groups (ILR, long-term continuous external monitoring, Holter monitoring). Categorical variables are described as counts and percentages, and count and continuous variables are summarised as mean with SD or median with IQR. Pair-wise unadjusted significance of differences were assessed by either general linear model F statistic for continuous variables or χ2 for categorical variables.

All-cause mortality was modelled as time-to-event using Cox proportional hazards regression with the exposure group as the primary predictor. Binary and cost outcomes were modelled using logistic regression and generalised linear models with a gamma distribution and logarithmic link. All models were further adjusted for CHA2DS2-VASc groups.

Additionally, given that patients in long-term care may be at higher risk for adverse outcomes, we conducted a subanalysis excluding patients who had long-term care stays of ≥45 days during the 6-month baseline period. We also conducted a subanalysis excluding patients who had received a previous monitoring device (ie, limiting to just the first monitoring device that a given patient received).

All analyses were performed using SAS Enterprise Guide, V.7.1.

Results

Baseline patient characteristics

The cohort of 48 901 individuals included 9235 patients with ILR, 29 103 with long-term continuous external monitor (>48 hours to 30 days), and 10 563 with Holter monitor only (≤48 hours); this cohort was used to assess all-cause mortality (online supplemental figure 1). In the overall cohort, the mean age was 69.9 (SD 11.9) years and 53.5% of patients were female (table 1). Overall, 8451 (17.3%) patients had an index date of device placement during an inpatient stay. In the 6-month baseline period, 5.1% of patients had a Holter monitor (6.3% prior to long-term continuous external monitor placement and 7.4% prior to ILR placement) and 4.2% had an external monitor. The mean CHA2DS2-VASc score was 5.3 (SD 1.5).

Table 1.

Baseline characteristics

Total Implantable loop recorder Long-term continuous external monitor Holter monitor Global p value
N % N % N % N %
Cohort N 48 901 100 9235 18.9 29 103 59.5 10 563 21.6
Age, years (mean, SD) 69.9 11.9 69.6 11.4 69.8 12.0 70.5 12.0 <0.001
Gender
 Female 26 148 53.5 4688 50.8 15 729 54.1 5731 54.3 <0.001
 Male 22 753 46.5 4547 49.2 13 374 46.0 4832 45.7 <0.001
Insurance type
 Commercial 12 417 25.4 2477 26.8 7567 26.0 2373 22.5 <0.001
 Medicare Advantage 36 469 74.6 6754 73.2 21 526 74.0 8189 77.5 <0.001
Index device year
 2016 5759 11.8 885 9.6 2934 10.1 1940 18.4 <0.001
 2017 7657 15.7 1311 14.2 4205 14.5 2141 20.3 <0.001
 2018 9200 18.8 1857 20.1 5245 18.0 2098 19.9 <0.001
 2019 11 081 22.7 2189 23.7 6834 23.5 2058 19.5 <0.001
 2020 10 610 21.7 1971 21.3 7158 24.6 1481 14.0 <0.001
 2021 4594 9.4 1022 11.1 2727 9.4 845 8.0 <0.001
Monitoring device placement setting
 Monitoring device placement date between a hospitalisation and discharge 8451 17.3 3777 40.9 3748 12.9 926 8.8 <0.001
 Monitoring device placement same day as emergency department visit 4762 9.7 2556 27.7 1670 5.7 536 5.1 <0.001
Procedures of interest
 Holter monitor utilisation during 6 months prior to index device placement 2502 5.1 681 7.4 1821 6.3 0 0 <0.001
 External cardiac monitor utilisation during 6 months prior to index device 2043 4.2 >2031* >21.0* 0 0 <11* <0.1* <0.001
CHA2DS2-VASc score and comorbidities (based on 6-month baseline period†)
 Heart failure 7772 15.9 1565 17.0 4467 15.4 1740 16.5 <0.001
 Hypertension 42 146 86.2 8238 89.2 24 916 85.6 8992 85.1 <0.001
 Diabetes 17 815 36.4 3531 38.2 10 434 35.9 3850 36.5 <0.001
 Coronary artery disease 17 535 35.9 3649 39.5 10 054 34.6 3832 36.3 <0.001
 Peripheral arterial disease 2317 4.7 405 4.4 1235 4.2 677 6.4 <0.001
 Thromboembolism 46 182 94.4 9082 98.3 27 685 95.1 9415 89.1 <0.001
 CHA2DS2-VASc—continuous (mean, SD) 5.3 1.5 5.4 1.5 5.3 1.5 5.3 1.6 <0.001
 CHA2DS2-VASc score of 2 or 3 6613 13.5 1041 11.3 3989 13.7 1583 15.0 <0.001
 CHA2DS2-VASc score of 4 or more 42 288 86.5 8194 88.7 25 114 86.3 8980 85.0 <0.001
Long-term care stays during baseline period
 Cumulative long-term care days (could be non-consecutive), mean (SD) 5.3 (11.2) 7.1 (12.1) 5.0 (10.4) 4.4 (12.1) <0.001
 ≥45 long-term care days 745 1.5 167 1.8 396 1.4 182 1.7 0.002
 ≥90 long-term care days 97 0.20 24 0.26 43 0.15 30 0.28 0.009

*Masked to meet small cell suppression policy.

†Baseline period includes the inpatient-stay adjusted index date and 182 days prior to the index date.

CHA2DS2-VASc score, 1 point for congestive heart failure, 1 point for hypertension, 1 point for diabetes mellitus, 2 points for ischaemic stroke/transient ischaemic attack/thromboembolism, 1 point for vascular diseases, 1 point for age 65–74 years, 2 points for age ≥75 years and 1 point for female sex.

After limiting to patients with at least 12 months of continuous enrolment, the cohort of patients to assess healthcare utilisation, costs and clinical outcomes included 6904 patients with ILRs, 22 079 with long-term continuous external monitors and 7916 with Holter monitors only. Baseline patient characteristics were similar to those in the cohort used to examine mortality (online supplemental table 6).

Unadjusted outcomes of ILRs versus external monitors

Mortality

Unadjusted mortality was not statistically different among the three patient groups: 4.2% of patients with ILRs, 4.2% with long-term continuous external monitors and 4.7% of patients with Holter monitors had died at 12 months (p=0.053) (online supplemental table 7 and figure 2). Unadjusted mortality was similar for patients with <45 days of long-term care during the baseline period and among those who had no baseline history of a prior rhythm monitoring device (online supplemental table 8).

Clinical outcomes

In unadjusted analyses, 23.2% of patients with ILRs, 13.7% with long-term continuous external monitors and 8.2% with Holter monitors were diagnosed with new AF at 12 months (p<0.001) (online supplemental table 9). Similarly, new initiation of oral anticoagulants was 25.5% in the ILR group, 13.4% in the long-term continuous external monitor group and 9.0% in the Holter group (p<0.001).

Twelve-month major gastrointestinal bleeding was not statistically different between the groups, while haemorrhagic stroke was higher among patients with ILRs (2.5% vs 1.6% vs 1.4%, respectively; p<0.001).

After the index date, 25.3% of patients with ILRs, 22.8% with long-term continuous external monitors and 22.4% with Holter monitors were hospitalised within 12 months (p<0.001, online supplemental table 10). Patients with ILRs also more often had at least one ED visit (46.9% vs 45.6% vs 43.7%, respectively, p<0.001) and a higher mean total number of office visits (24.9 vs 18.3 vs 18.0, respectively, p<0.001).

Costs of care

Among patients who received ILRs, the total costs of care at baseline (including index date, which means including the costs of the monitor, monitor placement and index hospitalisation) were higher than the other groups (ILR group mean $34 453±$32 357 vs long-term continuous external monitors mean $21 112±$27 850 vs Holter group mean $17 067±$31 266, p<0.001, online supplemental table 11). Mean total costs during 12-month follow-up, which did not include the index date and index hospitalisation, were also higher among patients who received ILRs ($26 967±$42 696) than for long-term continuous external monitors ($24 403±$39 291) and Holter monitors ($22 911±$39 729), p<0.001. Beneficiary out-of-pocket costs related to rhythm monitoring devices paid between the 6-month baseline period and 12 months following the index date were also higher among patients who received ILRs ($854±$1046) compared with those with long-term continuous external monitors ($64±$174) or Holter monitors ($27±$84), p<0.001.

Risk-adjusted outcomes of ILRs versus external monitors

Mortality

With patients who received long-term continuous external monitors as the reference group, patients who received ILRs had all-cause mortality at 12 months that was not statistically different, HR 1.00 (95% CI 0.89 to 1.12, table 2). Patients who received Holter monitors only had a higher hazard of death, HR 1.16 (95% CI 1.04 to 1.28) compared with those who received long-term continuous external monitors.

Table 2.

Adjusted mortality over 12-month follow-up

Level HR* (95% CI)
All-cause mortality ILR 1.00 (0.89 to 1.12)
All-cause mortality Holter 1.16 (1.05 to 1.28)

The reference group for all models is the long-term external continuous cardiac monitor (>48 hours to 30 days) group.

*Adjusted for CHA2DS2-VASc score.

ILR, implantable loop recorder.

Clinical and healthcare utilisation outcomes

With patients who received long-term continuous external monitors as the reference group, in the first 12 months, patients who received ILRs had a higher adjusted odds of a new diagnosis of AF (adjusted OR (aOR) 1.89, 95% CI 1.76 to 2.02) and both new diagnosis of AF and anticoagulant initiation (aOR 2.27, 95% CI 2.09 to 2.48, table 3). In contrast, patients who received Holter monitors had a lower adjusted odds of a new diagnosis of AF and anticoagulant initiation.

Table 3.

Adjusted clinical and utilisation outcomes over 12-month follow-up

Adjusted OR* (95% CI)
Adjusted clinical outcomes over 12 months of follow-up
Implantable loop recorder
 New atrial fibrillation diagnosis 1.89 (1.76 to 2.02)
 New atrial fibrillation diagnosis and anticoagulant initiation 2.27 (2.09 to 2.48)
 Haemorrhagic stroke 1.60 (1.34 to 1.93)
 Major gastrointestinal bleeding 1.02 (0.91 to 1.14)
 Other major bleeding 1.11 (0.84 to 1.46)
 Other minor bleeding 1.06 (0.97 to 1.16)
Holter monitor
 New atrial fibrillation diagnosis 0.57 (0.52 to 0.62)
 New atrial fibrillation diagnosis and anticoagulant initiation 0.54 (0.48 to 0.62)
 Haemorrhagic stroke 0.87 (0.70 to 1.08)
 Major gastrointestinal bleeding 1.04 (0.94 to 1.16)
 Other major bleeding 0.71 (0.51 to 0.97)
 Other minor bleeding 1.10 (1.01 to 1.19)
Adjusted utilisation outcomes over 12 months of follow-up
Implantable loop recorder
 All-cause acute inpatient 1.13 (1.06 to 1.21)
 All-cause emergency department 1.04 (0.99 to 1.10)
Holter monitor
 All-cause acute inpatient 0.99 (0.93 to 1.05)
 All-cause emergency department 0.93 (0.88 to 0.98)

The reference group for all models is the long-term external continuous cardiac monitor (>48 hours to 30 days) group.

*All models adjusted for CHA2DS2-VASc score.

The 12-month adjusted odds of haemorrhagic stroke was higher among patients who received ILRs compared with those who received long-term continuous external monitors (aOR 1.60, 95% CI 1.34 to 1.90). Additionally, patients with ILRs were also more likely to have any all-cause acute inpatient hospitalisation (aOR 1.13, 95% CI 1.06 to 1.21).

Costs of care

The adjusted cost ratio (total costs of care PMPM for patients who received ILRs compared with those who received long-term continuous external monitors) was 1.10 (95% CI 1.06 to 1.15, table 4). Medical cost ratios were higher with ILRs, while pharmacy costs were not significantly different. Patients who received Holter monitors had a lower cost ratio compared with those who received long-term continuous external monitors.

Table 4.

Adjusted per member per month (PMPM) cost outcomes over 12-month follow-up

Adjusted cost Ratio*
(95% CI)
Implantable loop recorder
 Total cost of care, PMPM 1.10 (1.06 to 1.15)
 Medical cost, PMPM 1.13 (1.07 to 1.18)
 Pharmacy cost, PMPM 1.02 (0.94 to 1.10)
 Health plan paid cost, PMPM 1.11 (1.06 to 1.17)
Holter monitor
 Total cost of care, PMPM 0.94 (0.90 to 0.98)
 Medical cost, PMPM 0.94 (0.89 to 0.98)
 Pharmacy cost, PMPM 0.95 (0.88 to 1.03)
 Health plan paid cost, PMPM 0.93 (0.89 to 0.97)

The reference group for all models is the long-term external continuous cardiac monitor (>48 hours to 30 days) group.

*All models adjusted for CHA2DS2-VASc score.

Discussion

In this study of approximately 49 000 patients who received cardiac monitoring after ischaemic or cryptogenic stroke, we found that ILRs were associated with increased new diagnoses of AF and initiation of oral anticoagulants compared with long-term continuous external monitors. However, there was no reduction in mortality. Given our large sample size and the overall mortality rate of ischaemic stroke due to AF (40% of patients with ischaemic stroke and AF may die within 1 year),22 if ILR use reduced mortality, this should have been apparent in our data. Costs of care for ILRs, including patient out-of-pocket costs, were significantly higher than for patients who received long-term continuous external monitors.

Our results are consistent with evidence showing that detecting occult AF through screening and initiating oral anticoagulation in patients at increased risk does not improve clinical outcomes. In the LOOP trial, which randomised 6004 patients aged 70–90 with one additional stroke risk factor to ILR versus usual care, the rate of AF detection >6 min in duration was threefold higher in the ILR group and oral anticoagulation was started in 29.1% versus 13.1% of patients, respectively.13 However, neither stroke or systemic embolisation nor major bleeding significantly differed. Similarly, meta-analyses comparing ILR with non-ILR monitoring in three studies among patients with stroke found greater likelihood of AF detection and initiation of oral anticoagulation but no significant decrease in risk of recurrent ischaemic stroke or mortality.10 12 Our analysis is consistent with these findings of increased likelihood of new AF diagnosis and oral anticoagulation initiation but without improvement in mortality compared with long-term continuous external monitors. Further, the average added cost of ILR use was approximately $13 500 per patient and patients with ILRs had many more outpatient visits than patients with external monitors—some of which were for ILR interrogation, which can be billed as frequently as every 30 days.

There are multiple possible explanations for our findings. First, the clinical significance of ILR detected AF may differ from clinically detected AF.23 A systematic review and meta-analysis found that AF detected after stroke was associated with a 26% lower risk of recurrent stroke compared with AF known before stroke.24 As research has shown that subclinical AF is associated with stroke risk,5 there is a need to define the clinical significance of AF detected on ILRs, particularly short, subclinical episodes of AF.25

Second, patients may experience harm after detection of AF, such as bleeding from oral anticoagulants (eg, haemorrhagic stroke) or adverse effects of rhythm control therapy (eg, antiarrhythmic medications) initiated after detection of AF, which mitigate any possible benefits. Given that AF detected by ILRs is nearly always asymptomatic (87% of patients in a study of nearly 700 000 ILR monitoring days never reported AF-related symptoms),26 if ILRs are not detecting arrhythmias that improve quality of life, it is important that they improve clinical outcomes.

Our findings are somewhat discordant from another observational study that examined ILRs among patients with cryptogenic stroke. Although that study also found increased rate of AF detection and initiation of oral anticoagulation among patients who received ILRs compared with all external cardiac monitors, the investigators found a reduced hazard of death associated with ILRs in a time-to-event analysis.27 The patients in our study were stratified into two external monitoring categories, with short-term Holter monitors distinguished from long-term continuous external monitors; Holter monitors were associated with a higher hazard of death and so the grouping of external monitors may explain the findings. Further, patients in our study had a higher CHA2DS2-VASc score, and there could be heterogeneity of effect based on patient risk for stroke. Finally, the other observational study had suggestion of non-random loss to follow-up of high-risk patients (eg, disabled, hospice and/or long-term care) from the ILR group compared with the control group.

Our findings of lack of reduction in mortality, but increased bleeding and costs, in the context of other published Randomized controlled trial (RCT) evidence finding no clinical outcome benefit from AF screening, suggests that there is a need to reconsider clinical practice guideline recommendations—which are based on AF detection, not on outcomes—for long-term rhythm monitoring to detect AF, since ILRs are increasingly used for that purpose. A recently published RCT that studied oral anticoagulation for device-detected atrial high-rate episodes was stopped early because of safety concerns and futility of efficacy,14 while another RCT found reduction in stroke or systemic embolism with apixaban compared with aspirin but that was offset by a similarly increased risk of bleeding.28 Additionally, although ILR placement is generally safe, as ILRs represent an implanted device, they are associated with some complications such as infection, site-related bleeding and pain29 30 as well as higher costs that are often borne directly by patients. The heterogeneity in rhythm monitoring strategies identified in our study among patients after ischaemic stroke also suggests a lack of clinical consensus as to the optimal rhythm monitoring approach.

Our study should be considered in the context of its limitations. First, as this is an observational study, it is susceptible to unmeasured confounding for variables that could not be matched. As our study represents the best available evidence, it highlights the need for an RCT of secondary prevention use of ILRs. Second, claims data have less reliability in distinguishing new ischaemic stroke from residual signs and symptoms of the original stroke, and so we did not include recurrent ischaemic stroke. Third, it is possible that the criteria for AF diagnosis differed across the monitoring modalities. However, as all three modalities monitor cardiac rhythm, we expect that this was unlikely. Fourth, our study is limited to findings at 1 year. It is possible that differences in mortality could emerge over longer follow-up.

Conclusion

Although ILRs were associated with a higher rate of new diagnoses of AF and more initiations of oral anticoagulation compared with long-term continuous external monitors after ischaemic or cryptogenic stroke, there was no reduction in mortality. This finding, along with an increased risk of haemorrhagic stroke and higher costs, raises the possibility of increasing harm caused by the increasing use of ILRs for this indication. These findings raise questions about the benefit of ILRs on clinical outcomes, including mortality, and indicate the urgent need for an RCT to guide clinical practice.

Acknowledgments

The authors thank Sarah Bitter, MA (University of California, San Francisco) for assistance in editing. Ms Bitter received support from Arnold Ventures.

Footnotes

Presented at: An earlier version of this work was previously presented at the 2023 American Heart Association Scientific Sessions. The citation is: Dhruva S, Ameli O, Redberg RF, Murillo J, Chaisson CE, Cohen K. Comparative Mortality, Safety, and Cost Among Stroke Patients Who Received Implantable Loop Records Compared to Continuous External Cardiac Monitors. Circulation. 2023;148:A15925.

Contributors: SD: study conception and design, data interpretation, drafting manuscript. JM: study conception and design, data interpretation, reviewing manuscript for important intellectual content. OA: study conception and design, data analysis and interpretation, reviewing manuscript for important intellectual content, guarantor. CEC: study conception and design, data analysis and interpretation, reviewing manuscript for important intellectual content. RR: study conception and design, data interpretation, reviewing manuscript for important intellectual content. KC: study conception and design, data interpretation, reviewing manuscript for important intellectual content.

Funding: SSD and RFR received funding for this study from Arnold Ventures. The funder had no role in the design and conduct of the study; collection, management, analysis and interpretation of the data; preparation, review or approval of the manuscript; and decision to submit the manuscript for publication.

Competing interests: SSD also receives research support from the Department of Veterans Affairs. SSD and RFR report serving on the Institute for Clinical and Economic Review (ICER) California Technology Assessment Forum. JM is a full-time employee of UnitedHealth Group and OA and KC (currently) and CEC (previously) are full-time employees of Optum Health, an arm of UnitedHealth Group and own stock in the company. OA had full access to all the data in the study and takes responsibility for the integrity of the data and the accuracy of the data analysis.

Provenance and peer review: Not commissioned; externally peer reviewed.

Supplemental material: This content has been supplied by the author(s). It has not been vetted by BMJ Publishing Group Limited (BMJ) and may not have been peer-reviewed. Any opinions or recommendations discussed are solely those of the author(s) and are not endorsed by BMJ. BMJ disclaims all liability and responsibility arising from any reliance placed on the content. Where the content includes any translated material, BMJ does not warrant the accuracy and reliability of the translations (including but not limited to local regulations, clinical guidelines, terminology, drug names and drug dosages), and is not responsible for any error and/or omissions arising from translation and adaptation or otherwise.

Data availability statement

Data are available upon reasonable request. The data are proprietary and are not available for public use but, under certain conditions, might be made available to editors and their approved auditors under a data use agreement to confirm the findings of this study.The manuscript’s guarantor, OA, affirms that this manuscript is an honest, accurate, and transparent account of the study being reported; that no important aspects of the study have been omitted; and that any discrepancies from the study as planned (and, if relevant, registered) have been explained.

Ethics statements

Patient consent for publication

Not applicable.

References

  • 1. Tsao CW, Aday AW, Almarzooq ZI, et al. Heart disease and stroke statistics-2023 update: A report from the American Heart Association. Circulation 2023;147:e93–621. 10.1161/CIR.0000000000001123 [DOI] [PubMed] [Google Scholar]
  • 2. Saver JL. Cryptogenic stroke. N Engl J Med 2016;374:2065–74. 10.1056/NEJMcp1503946 [DOI] [PubMed] [Google Scholar]
  • 3. Kamel H, Johnson DR, Hegde M, et al. Detection of atrial fibrillation after stroke and the risk of recurrent stroke. J Stroke Cerebrovasc Dis 2012;21:726–31. 10.1016/j.jstrokecerebrovasdis.2011.03.008 [DOI] [PubMed] [Google Scholar]
  • 4. Veltkamp R, Pearce LA, Korompoki E, et al. Characteristics of recurrent ischemic stroke after embolic stroke of undetermined source: secondary analysis of a randomized clinical trial. JAMA Neurol 2020;77:1233–40. 10.1001/jamaneurol.2020.1995 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5. Kim AS, Kamel H, Bernstein RA, et al. Controversies in stroke: should patients with embolic stroke of undetermined source undergo intensive heart rhythm monitoring with an implantable loop recorder Stroke 2022;53:3243–7. 10.1161/STROKEAHA.122.037342 [DOI] [PubMed] [Google Scholar]
  • 6. Kleindorfer DO, Towfighi A, Chaturvedi S, et al. Guideline for the prevention of stroke in patients with stroke and transient ischemic attack: A guideline from the American Heart Association/American Stroke Association. Stroke 2021;52:e364–467. 10.1161/STR.0000000000000375 [DOI] [PubMed] [Google Scholar]
  • 7. Sanna T, Diener H-C, Passman RS, et al. Cryptogenic stroke and underlying atrial fibrillation. N Engl J Med 2014;370:2478–86. 10.1056/NEJMoa1313600 [DOI] [PubMed] [Google Scholar]
  • 8. Gladstone DJ, Spring M, Dorian P, et al. Atrial fibrillation in patients with cryptogenic stroke. N Engl J Med 2014;370:2467–77. 10.1056/NEJMoa1311376 [DOI] [PubMed] [Google Scholar]
  • 9. Wachter R, Gröschel K, Gelbrich G, et al. Holter-electrocardiogram-monitoring in patients with acute ischaemic stroke (Find-AF(RANDOMISED)): an open-label randomised controlled trial. Lancet Neurol 2017;16:282–90. 10.1016/S1474-4422(17)30002-9 [DOI] [PubMed] [Google Scholar]
  • 10. Huang WY, Ovbiagele B, Hsieh CY, et al. Association between implantable loop recorder use and secondary stroke prevention: a meta-analysis. Open Heart 2022;9:e002034. 10.1136/openhrt-2022-002034 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11. Tsivgoulis G, Triantafyllou S, Palaiodimou L, et al. Prolonged cardiac monitoring and stroke recurrence: a meta-analysis. Neurology 2022;98:e1942–52. 10.1212/WNL.0000000000200227 [DOI] [PubMed] [Google Scholar]
  • 12. Ko D, Dai Q, Flynn DB, et al. Meta-analysis of randomized clinical trials comparing the impact of implantable loop recorder versus usual care after ischemic stroke for detection of atrial fibrillation and stroke risk. Am J Cardiol 2022;162:100–4. 10.1016/j.amjcard.2021.09.013 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13. Svendsen JH, Diederichsen SZ, Højberg S, et al. Implantable loop recorder detection of atrial fibrillation to prevent stroke (the LOOP study): a randomised controlled trial. Lancet 2021;398:1507–16. 10.1016/S0140-6736(21)01698-6 [DOI] [PubMed] [Google Scholar]
  • 14. Kirchhof P, Toennis T, Goette A, et al. Anticoagulation with edoxaban in patients with atrial high-rate episodes. N Engl J Med 2023;389:1167–79. 10.1056/NEJMoa2303062 [DOI] [PubMed] [Google Scholar]
  • 15. Ellenbogen MI, Andersen KM, Marine JE, et al. Changing patterns of use of implantable cardiac monitors from 2011 to 2018 for a large commercially-insured U.S. population. Medicine (Baltimore) 2021;100:e28356. 10.1097/MD.0000000000028356 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16. Optum Labs . OptumLabs and OptumLabs Data Warehouse (OLDW) Descriptions and Citation. Reproduced with permission from OptumLabs, 2020. [Google Scholar]
  • 17. Wallace PJ, Shah ND, Dennen T, et al. Optum Labs: building a novel node in the learning health care system. Health Aff (Millwood) 2014;33:1187–94. 10.1377/hlthaff.2014.0038 [DOI] [PubMed] [Google Scholar]
  • 18. Mansour MC, Gillen EM, Garman A, et al. Healthcare utilization and clinical outcomes after ablation of atrial fibrillation in patients with and without Insertable cardiac monitoring. Heart Rhythm O2 2022;3:79–90. 10.1016/j.hroo.2021.12.005 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19. Sehrawat O, Kashou AH, Van Houten HK, et al. Contemporary trends and barriers to oral anticoagulation therapy in non-valvular atrial fibrillation during DOAC predominant era. Int J Cardiol Heart Vasc 2023;46:101212. 10.1016/j.ijcha.2023.101212 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20. Shirley AM, Morrisette KL, Choi SK, et al. Validation of ICD-10 hospital discharge diagnosis codes to identify incident and recurrent ischemic stroke from a US integrated healthcare system. Pharmacoepidemiol Drug Saf 2023;32:1439–45. 10.1002/pds.5675 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21. Harb SC, Wang TKM, Nemer D, et al. CHA(2)DS(2)-Vasc score stratifies mortality risk in patients with and without atrial fibrillation. Open Heart 2021;8. 10.1136/openhrt-2021-001794 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22. Fang MC, Go AS, Chang Y, et al. Long-term survival after ischemic stroke in patients with atrial fibrillation. Neurology 2014;82:1033–7. 10.1212/WNL.0000000000000248 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23. Mandrola J, Foy A, Naccarelli G. Screening for atrial fibrillation comes with many snags. JAMA Intern Med 2018;178:1296–8. 10.1001/jamainternmed.2018.4038 [DOI] [PubMed] [Google Scholar]
  • 24. Fridman S, Jimenez-Ruiz A, Vargas-Gonzalez JC, et al. Differences between atrial fibrillation detected before and after stroke and TIA: a systematic review and meta-analysis. Cerebrovasc Dis 2022;51:152–7. 10.1159/000520101 [DOI] [PubMed] [Google Scholar]
  • 25. Sposato LA, Field TS, Schnabel RB, et al. Towards a new classification of atrial fibrillation detected after a stroke or a transient ischaemic attack. Lancet Neurol 2024;23:110–22. 10.1016/S1474-4422(23)00326-5 [DOI] [PubMed] [Google Scholar]
  • 26. Diederichsen SZ, Haugan KJ, Brandes A, et al. Natural history of subclinical atrial fibrillation detected by implanted loop recorders. J Am Coll Cardiol 2019;74:2771–81. 10.1016/j.jacc.2019.09.050 [DOI] [PubMed] [Google Scholar]
  • 27. Yaghi S, Ryan MP, Gunnarsson CL, et al. Longitudinal outcomes in cryptogenic stroke patients with and without long-term cardiac monitoring for atrial fibrillation. Heart Rhythm O2 2022;3:223–30. 10.1016/j.hroo.2022.02.006 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28. Healey JS, Lopes RD, Granger CB, et al. Apixaban for stroke prevention in subclinical atrial fibrillation. N Engl J Med 2024;390:107–17. 10.1056/NEJMoa2310234 [DOI] [PubMed] [Google Scholar]
  • 29. Diederichsen SZ, Haugan KJ, Højberg S, et al. Complications after implantation of a new-generation insertable cardiac monitor: results from the LOOP study. Int J Cardiol 2017;241:229–34. 10.1016/j.ijcard.2017.03.144 [DOI] [PubMed] [Google Scholar]
  • 30. Kheiri B, Sanghai S, Alhamoud H, et al. Meta-analysis of implantable loop recorder for atrial fibrillation detection in patients with ischemic stroke. Am J Cardiol 2021;161:115–6. 10.1016/j.amjcard.2021.08.001 [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary data

openhrt-2024-002714supp001.pdf (321.1KB, pdf)

Data Availability Statement

Data are available upon reasonable request. The data are proprietary and are not available for public use but, under certain conditions, might be made available to editors and their approved auditors under a data use agreement to confirm the findings of this study.The manuscript’s guarantor, OA, affirms that this manuscript is an honest, accurate, and transparent account of the study being reported; that no important aspects of the study have been omitted; and that any discrepancies from the study as planned (and, if relevant, registered) have been explained.


Articles from Open Heart are provided here courtesy of BMJ Publishing Group

RESOURCES