Abstract
Purpose:
The heart is a highly aerobic organ consuming most of the oxygen the body in supporting heart function. Quantitative imaging of myocardial oxygen metabolism and perfusion is essential for studying cardiac physiopathology in vivo. Here, we report a new imaging method that can simultaneously assess myocardial oxygen metabolism and blood flow in the rat heart.
Methods:
This novel method is based on the 17O-MRSI combined with brief inhalation of 17O-isotope labeled oxygen gas for quantitative imaging of myocardial metabolic rate of oxygen consumption (MVO2), myocardial blood flow (MBF), and oxygen extraction fraction (OEF). We demonstrate this imaging method under basal and high workload conditions in rat hearts at 9.4 T.
Results:
We show that this 17O MRSI–based approach can directly measure and image MVO2 (1.35–4.06 μmol/g/min), MBF (0.49–1.38 mL/g/min), and OEF (0.33–0.44) in the heart of anesthetized rat under basal and high workload (21.6 × 103–56.7 × 103 mmHg • bpm) conditions. Under high workload condition, MVO2 and MBF values in healthy rats approximately doubled, whereas OEF remained unchanged, indicating a strong coupling between myocardial oxygen metabolic demand and supply through blood perfusion.
Conclusion:
The 17O-MRSI method has been used to simultaneously image the myocardial metabolic rate of oxygen consumption, blood flow, and oxygen extraction fraction in small animal hearts, which are sensitive to the physiological changes induced by high workload. This approach could provide comprehensive measures that are critical for studying myocardial function in normal and diseased states and has a potential for translation.
Keywords: high workload, in vivo oxygen-17 (17O) MRS imaging (MRSI), myocardial blood flow, myocardial energy metabolism, myocardial metabolic rate of oxygen consumption, oxygen extraction fraction
1 |. INTRODUCTION
Cardiovascular disease is one of the leading causes of death worldwide. The heart is a highly aerobic organ that consumes large amounts of oxygen from the blood circulating in the body. Myocardial oxygen metabolism is tightly associated with the production of biochemical energy in the molecular form of adenosine triphosphate (ATP), which is critical to support the contraction/relaxation of cardiomyocytes to perform mechanical work under various working conditions. Many cardiovascular diseases have been linked to vascular abnormality and impaired energy metabolism. Therefore, it is important to exploit robust imaging approaches that can noninvasively and quantitatively measure myocardial metabolic rate of oxygen (MVO2), ideally together with myocardial blood flow (MBF), then to determine another important physiology parameter: oxygen extraction fraction (OEF) in vivo.
With technological advancements over the past few decades, many biomedical imaging tools are available to noninvasively study different aspects of cardiac patho-physiology and function in animal models and humans (please see recent reviews on this topic1,2 and the references cited therein). Of these, techniques based on MRS or MRSI and PET are the most relevant modalities for cardiometabolic imaging. However, for quantitative imaging of myocardial oxygen consumption rates in humans and/or large animals, 15O-PET is perhaps the only method that can directly measure and quantify MVO23,4 and is considered the gold standard. Because the high-energy positrons emitted during 15O decay have a wide range, about 4 times that of the 18F isotope used in the popular fluorodeoxyglucose-18 (18FDG)–PET imaging method, the spatial resolution of 15O-PET is 4 times lower than that of 18FDG-PET.5,6 Furthermore, the half-life of the 15O-isotope is only about 2 min,5,6 so 15O-PET measurements rely on an on-site cyclotron, which is not available at most research or clinic sites.
On the other hand, the in vivo oxygen-17 (17O) MRS imaging (MRSI) approach has been successfully developed and demonstrated at ultrahigh magnetic field strength for 3D imaging and quantification of the cerebral metabolic rate of oxygen (CMRO2) and possibly cerebral blood flow in rat and cat brains with a brief inhalation of 17O-isotope labeled oxygen gas (17O2),7–10 and for human brain applications.11–14 In this study, we use 3D 17O MRSI to evaluate the feasibility of quantitatively imaging regional MVO2 as well as MBF and OEF in the rat heart based on a single imaging measurement with short (2 min) inhalation of 17O2 at 9.4 T under both basal and high workload conditions.
2 |. METHODS
2.1 |. Principle and methodology
The principle of 17O-MRSI to measure oxygen metabolism is similar to the 15O-PET imaging method: Both approaches involve the inhalation of isotope-labeled oxygen gas (17O2 for 17O-MRSI and 15O2 for 15O-PET imaging), followed by the determination of the rate at which inhaled 17O-labeled or 15O-isotope-labeled oxygen is converted into 17O-labeled or 15O-labeled water in tissues through oxygen metabolism, which is the oxygen metabolism rate.8,9,13,15 However, the 17O-MRSI method has several advantages over the 15O-PET method. The natural abundance of 17O in oxygen gas is very low (0.037%) but can be enriched to >70%; this highly enriched oxygen gas is non-radioactive, stable, and commercially available. Moreover, 17O2 in tissue is “invisible” to in vivo 17O-MRS/MRSI detection, and 17O-MRS/MRSI can only detect the final oxygen metabolism product—17O-labeled water H 172O—thus, making imaging measurement and quantification simple.8,9 Metabolism of normal (or natural-abundance) oxygen in inspired air, dominated by 16O2, does not alter the H 172O signal in 17O MRS/MRSI.
Figure 1A illustrates the setup for an animal study in which a simple device was used to allow rapid switching between an inspired gas mixture containing normal natural-abundance oxygen gas and a gas mixture containing 17O-enriched oxygen gas, which was delivered to the animal’s lungs through a ventilator (note: a ventilator may not be required for spontaneously breathing animals). For an aerobic organ with high oxygen metabolic rate and blood perfusion (such as heart or brain), the detected 17O-MRSI signal and time-dependent changes in tissue H217O can be characterized by three phases, as shown in Figure 1B:
Phase I (before inhalation): Natural-abundance 17O-MRS signal of tissue H 172O; this can be used as an internal reference for quantifying tissue H217O concentration and its changes in the subsequent two phase periods.
Phase II (17O2 inhalation): 17O-MRS signal during a brief 17O2 inhalation (usually lasting a few minutes), showing a rapid increase of tissue H 172O content through the metabolism of inhaled 17O2 in cells; the dynamic H217O change can be used to quantify MVO2.
Phase III (after inhalation): 17O-MRS signal after the 17O2 inhalation, in which H217O molecules produced via the metabolism of inhaled 17O2 in tissue begin to decay due to washout by blood perfusion; they can be used as an endogenous perfusion tracer to measure and quantify MBF.16
FIGURE 1.

(A) Schematic of a simple setup that allows rapid switching between a natural-abundance oxygen gas mixture and an 17O-enriched oxygen gas mixture sent to the animal’s lung by a ventilator and used to perform cardiac 17O-MRS imaging in rats. (B) For organs with high oxygen metabolic rate and blood perfusion, such as brain or heart, the dynamics of cardiac H217O signal can be characterized by three phases. Phase I: Steady-state natural-abundance 17O-water signal before 17O2 inhalation. Phase II: A brief period of 17O2 inhalation (indicated by a gray bar, usually a few minutes), resulting in a rapid increase in tissue H217O signal. Phase III: Following the 17O2 inhalation period, the metabolized H217O in myocardial tissue begins to decay and can serve as an endogenous perfusion tracer.
The mass balance relationship for the concentration of labeled H217O in myocardium during inhalation of 17O2 gas is given as follows9:
| (1) |
where Ca, Cm, and Cv are the H217O concentration expressed in excess of the natural abundance H217O concentration in arterial blood, myocardial tissue and venous blood, respectively, as a function of the 17O2 inhalation time t (unit = minute). One labeled 17O2 converts to two H217O molecules through oxidative metabolism; thus, a constant of 2 is used in Eq. (1). The parameter α in Eq. (1) is the 17O enrichment fraction in the inhaled 17O2 gas. Natural-abundance H217O concentration (equal to 20.35 μmol per gram tissue water or per gram water in blood [see Ref. 9]) can be used to calibrate the absolute concentrations of Cm(t), Ca(t), and Cv(t). For convenience, the unit for Cm is chosen as μmol/(g heart tissue water), and the units for Ca and Cv are μmol/(g blood water), where parameters f1 (=1.266) and f2 (=1.077) are conversion factors used for consistency of units applied in Eq. (1). Because the tissue water composition is similar between brain and heart,17 the same f1 and f2 conversion factors can be applied to brain and heart tissues.9
2.2 |. Quantification of MVO2 (Phase II)
According to the Taylor’s Theorem, Cm(t) during 17O2 inhalation can be written as
| (2) |
Because Cm is zero at the beginning of the 17O2 inhalation (i.e., Cm[0] = 0); thus, a0 = 0. Similarly, the second term on the right side of Eq. (1) can also be written as
| (3) |
with the boundary condition that both Cv and Ca are zero at the start of the inhalation (i.e., Cv[0] = Ca[0] = 0). Therefore, Eq. (1) becomes
| (4) |
Because Eq. (4) holds for any t value, applying the Polynomial Theorem to Eq. (4) at t = 0 leads to
| (5) |
Thus,
| (6) |
When Cm(t) is regressed by a polynomial function in the form of Eq. (2) with a0 = 0, the fitting coefficient of the linear term (i.e., a1) can be used to calculate MVO2 according to Eq. (6).
In principle, the higher the order of the polynomial used, the better the fit. However, when fitting a polynomial equation on experimental data with a limited SNR, the reliability of the fitting results is poor due to the overfitting of the data to polynomials of larger degrees; therefore, in practice, only linear and quadratic terms in Eq. (2) were used to fit the Cm(t) time courses for each imaging voxel to improve the fitting reliability. Our previous work showed that quadratic fitting provides accurate results for estimating metabolic rate of oxygen in rat brains, in contrast to linear fitting that could underestimate metabolic rates by up to 10% for rat brain data with several minutes of 17O2 inhalation.18 In this study, we use a quantification approach based on the quadratic fitting.
2.3 |. Quantification of MBF (Phase III)
During Phase III (after inhalation), the decay of the tissue H217O signal or concentration approximately follows the following exponential function:
| (7) |
Based on our early work of rat brains under various conditions,16 the determined decay rate (k) is approximately 1.86 times slower than that measured by the classic tracer method using a bolus injection of H217O into a carotid artery; thus,
| (8) |
2.4 |. Quantification of OEF
| (9) |
where Ca,O2 is the artery oxygen concentration and is treated as a constant. The common unit of the Ca,O2 is mL-O2/dL-blood and can be converted to μmol/mL-blood for matching the unit of MVO2 to MBF ratio according to Avogadro’s law, and the conversion factor is 2.24. In this study, we used the Ca,O2 value of 15.1 mL-O2/dL-blood measured in healthy and young rats as reported in the literature19 to calculate the myocardial OEF in the rat heart.
2.5 |. Materials and experiment
Eight Sprague–Dawley rats (body weight: 318 ± 38 g) were used in this study. The rats were placed in an induction box under 5% isoflurane for several minutes, after which the animals were intubated and mechanically ventilated under gaseous anesthesia (2% isoflurane in a mixture of 70% nitrous oxide and 30% oxygen). The femoral artery and vein were cannulated for physiological monitoring, blood sampling, and chemical administration. The animals’ rectal temperature was maintained at 37.1 ± 0.3°C using heated circulating water; the arterial blood pressure and heart rate were monitored and maintained under normal physiological conditions throughout the experiment. The ventilated oxygen gas could be switched between natural-abundance (most time) and 17O-enriched (up to 89% 17O enrichment and for 2 min of inhalation) O2 gas using the device shown in Figure 1A. The animals were studied under either basal and/or high workload condition using an intravenous bolus injection of 40 μg/(kg body weight) dobutamine and dopamine.
To achieve high SNR and temporal resolution for in vivo 17O-MRS/MRSI data in the rat heart, we developed a novel RF coil configuration consisting of two electrically decoupled RF coils. A small 17O surface coil (~1 cm diameter) with electric isolation and wrapped with soft Teflon film around the coil plane was inserted into the rat chest via thoracotomy and placed between the chest (inner) wall and the heart for holding the heart organ as illustrated in Figure 2A; the incision of the muscles was closed by suture after implanting the coil. Another half-volume proton (1H) RF coil was positioned around the rat’s body while the animal was in prone position with a RF magnetic field (B1) perpendicular to that generated by the 17O surface coil, resulting in passive decoupling between the two RF coils. The inserted 17O surface coil has two advantages: It provides a higher SNR for the detection of the signals from the heart due to the proximity between the RF coil and imaging object, enabling higher spatiotemporal imaging resolution; it also significantly reduces the contamination signals from surrounding chest muscle and the heart motion induced by breathing and lung motion. No additional gating or motion control was applied in this study. The University of Minnesota Institutional Animal Care and Use Committee approved the animal protocols used in this study.
FIGURE 2.

(A) Representative 1H MRI of rat chest and heart tissues in coronal (left panel) and sagittal (right panel) orientations, the location of the 17O surface coil is depicted on the images. (B) Stack plots of global heart H217O resonance signals (3 s per 17O spectrum) and the corresponding H217O signals time course measured before, during, and after a 2-min inhalation (indicated by gray bars) of 17O2 gas. D, dorsal; F, foot; H, head; L, left; R, right; V, ventral.
All 17O-MRS/MRSI experiments were conducted on a 9.4T/31-cm bore animal magnet (Magnex Scientific, Oxford UK) with a Varian INOVA console (Varian Inc., Palo Alto, CA, USA). The 1H RF half-volume coil was operated at 400 MHz, and the 17O RF surface coil was operated at 54.3 MHz.
A 3D-CSI method based on the Fourier series window (FSW) k-space weighting20,21 was applied in this study. The FSW weighting applied for the CSI acquisition is based on the Fourier coefficients of a predetermined voxel shape following the optimal termination of the series. The FSW-based CSI approach is characterized by better sensitivity and smaller out-of-voxel contamination as compared with the conventional Fourier transform approach.20,21 The 3D-CSI acquisition parameters were 9 × 9 × 5 phase encodes, 3 × 3 × 2.5 cm3 FOV, 3.3 × 3.3 × 5 mm3 nominal voxel size, 45-ms TR, 30-kHz spectral width, 11-s acquisition time per 3D 17O CSI. Multiple CSI volumes were collected to capture the dynamic H217O signal change in the heart across the three phases as illustrated in Figure 1B. A hard RF pulse was applied to excite the 17O water resonance, and its power was calibrated using a single-pulse acquisition sequence with varied RF pulse power to optimize the 17O signal of the natural abundance water dominated by the rat heart. The FID from each CSI voxel was zero-filled before performing Fourier transformation, and a line broadening (100 Hz) was applied to enhance SNR.
3 |. RESULTS
Figure 2A shows 1H structural images in two orientations covering the rat chest, heart, and other adjacent tissues. The position of the 17O surface coil (orange in Figure 2A) is marked schematically in the image, indicating its close proximity to the heart, and is used to detect the 17O water signal primarily from the myocardium. Figure 2B displays a stack plot of global myocardial 17O water (H217O) spectra with a high temporal resolution of 3 s per 17O spectrum and superior sensitivity, as well as the corresponding H217O signal time course before, during, and after a 2-min 17O2 gas inhalation. The three distinct phases of myocardial H217O signal changes are highly similar to those observed in the rodent brains.7,9,18,22,23 The first phase (before inhalation) measures the natural-abundance 17O-water signal from the myocardium, which can be used to calibrate the absolute H217O concentration7,9,18,22,23 in the myocardium for quantifying MVO2. The second phase is characterized by rapid accumulation of myocardial H217O content, primarily 17O-labeled water produced in mitochondria by myocardial 17O2 metabolism; the accumulation rate is tightly correlated to MVO2. The third phase shows that after 17O2 inhalation is terminated, the H217O signal decays as labeled H217O water is washed away from the myocardium via perfusion; its decay rate constant (k = 0.56 min−1 in this measurement) is related to myocardial blood perfusion (i.e., MBF). According to (Eqs. 6) and (8), for this particular measurement, the values of global heart MVO2 and MBF were determined to be 1.9 μmol/g/min and 1.1 mL/g/min, respectively.
Figure 3A presents the imaging results from another rat, showing the H217O time courses with 2 min of 17O2 inhalation from four representative 17O-CSI voxels located inside the heart and the corresponding 1H rat heart image. Excellent sensitivity and high temporal resolution (11 s per CSI volume) of the 17O-CSI make it possible to image the dynamics of the myocardial H217O in situ. The H217O time courses of these 4 voxels were well characterized with three distinct phases and relatively small signal fluctuation, resulting in MVO2 values in the range of 1.82–2.03 μmol/g/min and MBF values in the range of 0.47–0.65 mL/g/min, respectively. Figure 3B shows the 17O water signal maps of the same 17O-CSI slice at three time points imaged before/after the 17O2 inhalation (see Figure 3A for time labels), demonstrating the spatial distribution of the H217O signal in the 17O-RF coil sensitive region and its changes in response to 17O2 inhalation, metabolism and washout.
FIGURE 3.

(A) Cardiac 1H MRI of a representative rat with heart outlined by a yellow dashed line; the locations of four selected CSI voxels inside the heart from a representative CSI slice are marked by dashed circles (center panel). The H217O signal time courses of these voxels and the corresponding metabolic rate of oxygen consumption (MVO2) and myocardial blood flow (MBF) values are displayed for each selected voxel. (B) H217O signal maps of the same CSI slice at different time points before and after 17O2 gas inhalation, showing the distribution of H217O signals in the cardiac region covered by the 17O RF surface coil, and the change of H217O signal before and after 17O2 inhalation. Time labels and inhalation period are shown in (A, left-top panel). F, foot; H, head; L, left; R, right.
Figure 4 illustrates the results based on the average of multivoxel data from three 17O-CSI slices and the values of MVO2 and MBF in each slice, indicating a similar trend of these changes along the slice direction (averaged values from the three slices: MVO2 = 1.88 μmol/g/min and MBF = 0.60 mL/g/min).
FIGURE 4.

Cardiac 1H MRI in two orientations, showing the location of the 17O-RF surface coil and the positions of three representative 17O-CSI slices and the metabolic rate of oxygen consumption (MVO2) and myocardial blood flow (MBF) values from the averaged multivoxels for each 17O-CSI slice. D, dorsal; F, foot; H, head; L, left; R, right; V, ventral.
We also measured the dynamics of the myocardial H217O signals and calculated the corresponding MVO2 and MBF values in the same rat heart under basal and high workload conditions. Two examples are presented herein. Figure 5 shows the results based on the global H217O signals (only used 17O surface coil localization), and Figure 6 displays the time courses of a representative CSI voxel located inside the heart and the H217O maps of a selected CSI slice across the rat heart at different times and conditions. Apparently, infusion of mixed dobutamine and dopamine largely increased the blood pressure and heart rate, leading to a high workload condition with greatly increased heart-rate pressure product (RPP, in mmgH·bpm bpm). Accordingly, the myocardial 17O water signal increased faster during the 17O2 inhalation and reached a higher peak at the end of the 17O2 inhalation (Phase II as illustrated in Figure 1B) under the high workload condition, resulting in a higher MVO2 rate (e.g., MVO2, high-workload = 3.18 μmol/g/min vs. MVO2, basal = 1.78 μmol/g/min as shown in Figure 5B,C). The H217O signal also decayed faster during the post-inhalation period (Phase III as illustrated in Figure 1B) under the high workload condition, indicating a higher perfusion rate (e.g., MBFhigh-workload = 1.37 mL/g/min vs. MBFbasal = 0.71 mL/g/min as shown in Figure 5B,C). Similar increases of MVO2 and MBF were also detected in a representative 3D 17O-CSI voxel located inside another rat heart (cycled in Figure 6A), showing again significantly elevated MVO2 = 2.66 μmol/g/min and MBF = 1.12 mL/g/min under the high workload condition as compared to the basal condition with MVO2 = 1.37 μmol/g/min and MBF = 0.64 mL/g/min. These results collectively show that myocardial oxygen consumption rate and perfusion approximately double as myocardial workload increases and suggest a tight coupling relationship between myocardial oxygen metabolism and perfusion under basal and high workload conditions.
FIGURE 5.

(A) Illustration of representative 1H cardiac MRI (in axial and sagittal orientations) of another rat and the location of the 17O-RF surface coil. Stack plots of global heart H217O resonance signals (3 s per spectrum) and the corresponding H217O time courses measured before, during, and after a 2-min inhalation (indicated by gray bars) of 17O2 gas under basal (B) and high workload (C) conditions. The values of metabolic rate of oxygen consumption (MVO2), myocardial blood flow (MBF), and rate pressure product for each condition are displayed. D, dorsal; F, foot; H, head; L, left; R, right; V, ventral.
FIGURE 6.

(A) Cardiac 1H MRI and the myocardial H217O time course of a representative 3D 17O-CSI voxel inside the rat heart measured before, during, and after a brief (2-min) 17O2 inhalation under basal and high workload conditions. The position of heart and voxel are indicated by a dashed outline and circle, respectively, on the 1H MRI; the values of metabolic rate of oxygen consumption (MVO2), myocardial blood flow (MBF), and rate pressure product (RPP) for each condition are also displayed. (B) H217O signal maps of the same CSI slice at different time points before and after 17O2 gas inhalation under basal and high workload conditions. Time labels and inhalation period are shown in (A). F, foot; H, head; L, left; R, right.
With the MVO2 and MBF values of the same heart under the same condition, we can readily calculate OEF of the myocardial tissue following (Eq. 9). The individual and averaged MVO2, MBF, OEF, and RPP of all eight rats studied are summarized in Table 1. We found statistically significant increases in mean MVO2 and MBF under high workload conditions compared with basal conditions. Figure 7 shows the correlation analysis results of MVO2 versus MBF (Figure 7A), MVO2 versus RPP (Figure 7B), MVO2 versus OEF (Figure 7C), as well as their linear regression curves, resulting in the following two approximated equations:
| (10) |
| (11) |
TABLE 1.
Summary of the measurement results in healthy rats (n = 8).
| Basal condition | Higher workload | |||||||
|---|---|---|---|---|---|---|---|---|
| Rats | MVO2 (μmol/g/min) |
MBF (mL/g/min) |
OEF | RPP |
MVO2 (μmol/g/min) |
MBF (mL/g/min) |
OEF | RPP |
| 1 | 1.83 | 0.81 | 0.33 | 36 586 | 2.41 | 0.86 | 0.42 | 47 239 |
| 2 | 1.71 | 0.65 | 0.39 | 42 211 | - | - | - | - |
| 3 | 1.35 | 0.49 | 0.41 | 27 530 | - | - | - | - |
| 4 | 2.80 | 1.24 | 0.33 | 24 609 | 4.06 | 1.38 | 0.44 | 36 000 |
| 5 | 2.80 | 0.96 | 0.43 | 35 711 | 2.88 | 1.22 | 0.35 | 41 622 |
| 6 | 1.89 | 0.71 | 0.39 | 21 677 | 1.97 | 0.73 | 0.40 | 25 046 |
| 7 | 1.78 | 0.71 | 0.37 | 25 818 | 3.18 | 1.36 | 0.35 | 56 680 |
| 8 | 2.08 | 0.83 | 0.37 | 26 867 | 2.24 | 0.91 | 0.37 | 34 656 |
| Mean | 2.03 | 0.80 | 0.38 | 30 126 | 2.79 * | 1.08 * | 0.39 | 40 207 * |
| SD | 0.52 | 0.23 | 0.03 | 7138 | 0.76 | 0.28 | 0.04 | 10 965 |
Indicating statistically significant changes with p < 0.05 (Student t-test) were detected between the two conditions.
Abbreviations: MBF, myocardial blood flow; MVO2, metabolic rate of oxygen consumption; OEF, oxygen extraction fraction; RPP, rate pressure product.
Note: Only the listed values with the * sign indicates statistically significant for the high working load condition as compared to the basal condition with a p value of < 0.05 (in bold).
FIGURE 7.

Regression analysis results showing a strong linear correlation between cerebral blood flow (CBF) and metabolic rate of oxygen consumption (MVO2) (A), a positive correlation between rate pressure product (RPP) and MVO2 (B), and oxygen extraction fraction (OEF) values were insensitive to changes in MVO2 in all rats studied (C). MBF; myocardial blood flow.
We also found that the mean OEF values (OEFbasal = 0.38 ± 0.03 and OEFhigh-workload = 0.39 ± 0.04) are almost identical under basal and high workload conditions with RPPbasal = (3.0 ± 0.7) × 104 mmHg·bpm and RPPhigh-workload = (4.0 ± 1.1) × 104 mmHg·bpm, respectively, in the rat hearts anesthetized using isoflurane. On average, a 33% increase in RPP (from 3.0 to 4.0 × 104 mmHg·bpm) resulted in a 37% increase in MVO2 (from 2.03 to 2.79 μmol/g/min) and 35% increase in MBF (from 0.80 to 1.08 mL/g/min) (see details in Table 1). Together, these results demonstrate that the 17O-MRSI method is sensitive and robust for quantitatively imaging changes in myocardial metabolism and perfusion in vivo in a noninvasive manner.
4 |. DISCUSSION
Like the brain, the heart relies on extensive ATP energy production from oxidative metabolism to support normal cardiac function. Most of the ATP molecules used by the normal adult heart are produced by the oxidation of fatty acids in the mitochondria, and the remainder is by the oxidation of glucose.24–26 Because the P:O (phosphorylation vs. oxygen metabolism) ratio of fatty acid oxidation is relatively lower than that of glucose oxidation,27 for the same ATP synthesis rate, more oxygen must be consumed when fatty acids are used as substrates for energy metabolism. A healthy human heart can synthesize approximately 6 kg of ATP molecules per day,28 which is similar to the 5.7 kg of ATP molecules produced by the human brain per day,29 although the heart weight is 3–4 times lighter than the brain. The high activities of oxygen metabolism and substrate oxidation in the heart are closely associated with high coronary blood supply and tissue perfusion to meet the high oxygen demand of the heart even in the basal state.30 Blood flow and oxygen consumption are highly dynamic and tightly coupled under working state, as shown in Figure 7A. Abnormality in energy metabolism is associated with cardiac dysfunction and diseases; for example, obesity and diabetes have increased myocardial oxygen consumption and fatty acid oxidation rates, resulting in reduced cardiac efficiency.31 Therefore, quantitative and robust imaging of myocardial oxygen metabolism, blood flow, and oxygen extraction fraction is essential for assessing and understanding cardiac physiopathology.
The 15O-PET imaging method was established decades ago to image oxygen consumption and blood flow rates and OEF in the brain32 or heart.3,4 By inhaling oxygen gas enriched with radioactive 15O-isotope (15O2) and monitoring the spatial distribution and accumulation rate of 15O-isotope labeled signals in tissues, 15O-PET can determine the regional metabolic rate of oxygen consumption. However, 15O-PET is unable to distinguish the radioactive signals between the 15O2 molecules bound to hemoglobin and the 15O atoms incorporated into H215O. To overcome this shortcoming, two additional measurements are commonly required to determine blood volume with inhaled C15O and blood flow with an intravenous H215O tracer.32 Therefore, three 15O-PET scans with different radioactive tracers are required to quantitatively determine the metabolic rate of oxygen consumption, blood flow, and OEF based on a complex model with a number of approximations and assumptions. This presents challenges for longitudinal studies with multiple measurements due to the safety concern of excess radiotracers taken by the body.
In this pilot study, we demonstrate for the first time the feasibility of a novel 3D 17O-MRSI method for quantitative imaging of three important quantities: MVO2, MBF, and OEF via a single imaging measurement with a brief (2 min) inhalation of 17O-labeled oxygen gas (17O2). Although 15O-PET and 17O-MRSI imaging methods are similar in methodology and principle, 17O MRSI offers merits. First, the 17O isotope is stable and non-radioactive. Second, 17O MRSI specifically detects the metabolically produced H217O from inhaled 17O2 without the confounding signals from 17O2 molecules bound to hemoglobin or dissolved in tissues, so the 17O signal is only detectable when 17O2 is incorporated into water via oxygen metabolism.8,9 Because of this unique specificity, quantification of MVO2 from 17O-MRSI data becomes simpler (see Section 2) compared with the 15O-PET imaging method. Third, the metabolically generated H217O in the myocardium can serve as an endogenous perfusion tracer for determining MBF. These merits allow the simultaneous imaging of MVO2, MBF, and OEF in small animals with a single noninvasive 17O-MRSI measurement and a brief 17O2 inhalation. Moreover, the sensitivity of 17O MRSI is significantly improved using high or ultrahigh-field MRI scanner,33,34 enabling high spatiotemporal imaging resolution and high-quality images, as illustrated in this study at 9.4 T.
To reduce the heart motion caused by breathing, and achieve optimal detection sensitivity, we designed an implantable 17O-RF surface coil to hold the rat heart when performing the dynamic 17O-MRSI study with high spatiotemporal resolution. From the structural 1H MRI and 3D 17O MRSI (Figures 3 and 6), the global signal detected by the 17O surface coil was dominated by the heart with negligible contamination from surrounding chest muscle. Therefore, the derived parameters based on the global H217O signal and its dynamic change should primarily reflect the metabolic rate of oxygen consumption, blood flow, and OEF of the heart (Figures 2 and 5). Although global H217O signal does not provide regional information within the heart, it offers excellent sensitivity to monitor the dynamic change of the myocardial tissue H217O metabolized from inhaled 7O2 (Figures 2B and 5B,C), thereby robustly determining the MVO2 and MBF values.
The 17O-RF coil configuration and high field strength at 9.4 T provide excellent detection sensitivity, making it possible to perform 3D 17O MRSI with relatively high spatial (nominal voxel size: 0.054 mL) and temporal (11 s per 3D 17O-MRSI volume) resolution (Figures 3 and 6). Considering that the heart weight of the Sprague–Dawley rats is about 1.1 g,35 a myocardial tissue density is 1.1 g/mL, the myocardial tissue volume is estimated to be about 1.0 mL, and thus covered by up to 18 17O-CSI voxels. Nevertheless, we found that the MVO2 and MBF values from four representative voxels as shown in Figure 3A (MVO2: 1.82–2.03 μmol/g/min; MBF: 0.47–0.65 mL/g/min) or the averaged values from three 17O-CSI slices as shown in Figure 4 (MVO2 = 1.88 μmol/g/min; MBF = 0.65 mL/g/min) are in an excellent agreement with the global measurement results from the same animal (MVO2 = 1.89 μmol/g/min; MBF = 0.71 mL/g/min, see Rat 6 in Table 1). The lack of regional differences in the measured MVO2 and MBF values may be due to partial volume effects (see more discussion later).
The 17O-MRSI measurement is sensitive to the heart workload. This study shows approximately doubling the MVO2 and MBF values under the high workload condition; for instance, MVO2 and MBF increased 79% and 93%, respectively, based on the global measurement in an isoflurane anesthetized rat (Figure 5), and increased 94% and 75%, respectively, in a representative voxel in the heart of a different rat (Figure 6). The results are consistent with an isolated and perfused rat heart study, showing a 92% increase of MVO2 at high workload condition using high perfused Ca2+ concentration.36 The coupling relationship between MVO2 and the workload strength as quantified by the RPP parameter is shown in Figure 7B, and a similar correlation was also reported in literature.3,4 As expected in healthy hearts, there was a strong, linear correlation between MVO2 and MBF measured under basal and high workload conditions (Figure 7A and Eq. [11]), resulting in OEF values (OEFbasal = 0.38 ± 0.03 and OEFhigh-workload = 0.39 ± 0.04) that are insensitive to changes in MVO2 and MBF under normal physiology conditions.
It has been reported in the literature that the MVO2 values of normal human3,37,38 and anesthetized dog4,39–41 hearts measured by conventional methods are about 4.5–6.5 and 3.2–4.7 μmol/g/min, respectively; however, due to the difficulty of measuring MVO2 in small animals, there is a lack of MVO2 values for normal rats in the literature. The MVO2 (1.35–4.06 μmol/g/min) obtained in healthy rats in this study is similar to the range of humans and dogs, but lower than expected given the higher metabolic activity of rodents. Similarly, the MBF (0.49–1.38 mL/g/min) and OEF (0.33–0.44) obtained in this work are also lower than those reported values of healthy humans with MBFhuman ≈ 0.4–1.2 mL/g/min and OEFhuman ≈ 0.6–0.7,3,37,38,42,43 dogs with MBFdog ≈ 0.6–1.3 mL/g/min and OEFdog ≈ 0.5–0.64,40,41,44 or rats with MBF ≈ 1.5–6.5 mL/g/min.45–48 rat The main reason for this underestimation in the present study is the uncorrected partial volume effect of the intracardiac blood pool, although in cardiac PET studies, the systematic underestimation in measurements of myocardial radiotracer concentration due to wall motion and small transmural wall thickness has been corrected.49,50 If one assumes a myocardial tissue fraction of 0.5 in the region of interest or imaging voxel, and that the dynamic change in H217O concentration in the blood pool is half that of the myocardium during the 17O2 inhalation, a 3-fold increase in MVO2, 50% or smaller increase in MBF and about 2-fold increase in OEF can be anticipated. It seems more reasonable if a similar correction is applied to the results obtained in the current study. Further work is needed to improve quantification.
In the present study, we independently processed Phases II and III of the myocardial H217O time course to quantify MVO2 and MBF, respectively (see Section 2). However, for organs or tissues with low oxygen metabolic rate and blood flow, such as skeletal muscle at rest, or even human brain or heart, a sophisticated quantification model combining Phases II and III (i.e., a two-phase model) is needed to correctly determine myocardial oxygen consumption rate13,23 or to measure CMRO2, cerebral blood flow, and thus OEF in the human brain.14 Therefore, for human cardiac imaging application using the 17O-MRSI method, a two-phase quantification model should be considered.
We designed and applied an implantable 17O-RF surface coil on a rat model to achieve an excellent SNR for 3D 17O-MRSI measurements; however, a small surgery for coil implantation is required. Surgery can be avoided if the 17O-RF coil is placed outside the chest, which is preferable for close-chest or human applications, although SNR may be reduced. Recently, we demonstrated the feasibility of performing a completely noninvasive deuterium (2H) MRSI (DMRSI) study in a close-chest rat heart model51; and a novel machine learning–based method that greatly improves SNR and enables high-resolution dynamic DMRSI study of brain tumor in rats.52 We believe the potential of the 17O-MRSI technique for non-invasive imaging MVO2, MBF and OEF in the human heart in normal and/or diseased states can be realized if these two approaches are combined with a 3D 17O-MRSI method. The 17O MRSI or 17O MRI has been applied to map human brain CMRO2 at varied magnetic field strength from 3 T to 9.4 T.11–14,53 It has also been shown that the natural-abundance H217O signal (i.e., Phase I) in the human myocardium can be imaged at the clinical MRI strength of 3 T.53 Therefore, by introducing a biphasic quantification model14 and a machine learning–based denoising method in a 17O-MRSI approach capable of simultaneous MVO2, MBF and OEF imaging, one should be able to apply this technique to human cardiac imaging.
McCommis et al. has reported an alternative myocardial imaging approach based on the proton T1ρ MRI for indirectly detecting the change of the myocardial H217O content metabolized from the injected 17O2-enriched artificial blood, and thus to determine MVO2 in canine.54 The indirect 17O method based on proton imaging read-out is expected to provide higher detection sensitivity than the direct 17O imaging method; however, in practice the reported method has several technical limitations and drawbacks. First, it is difficult to accurately quantify tissue H217O concentration and MVO2 value due to low sensitivity in detecting proton signal changes that are directly related to changes in tissue H217O content, and it requires multiple T1ρ MRI measurements at two spin-locking frequencies and each with different spin-locking times for calibration. Second, injection of 17O2-enriched artificial blood can alter blood oxygenation level, resulting in confounding BOLD signal contributions, significantly increasing the uncertainty in determining true MVO2 values. Third, the T1ρ measurement is highly sensitive to the static magnetic field (B0) and shimming, cardiac pulsation, and motion; therefore, controlling the electrocardiogram trigger during imaging acquisitions is critical to reduce imaging signal fluctuations caused by cardiac motion. Additionally, it requires intravenous injection of large amounts of 17O2-enriched artificial blood, which is not ideal for potential clinical applications. In contrast, the 17O-MRS/MRSI technique presented herein overcomes the technical challenges faced by the indirect T1ρ MRI approach and provides a simple and robust myocardial imaging method that is not only capable of quantitatively imaging MVO2, but also MBF and OEF from a single imaging measurement.
5 |. CONCLUSIONS
This study demonstrates the feasibility and promise of a noninvasive 3D 17O-MRSI method for quantitatively imaging myocardial metabolic rate of oxygen consumption, blood flow, and oxygen extraction fraction with a brief inhalation of 17O2 and a single imaging measurement. This novel cardiac imaging method is simple, robust, and sensitive to changes in cardiac physiology. The results showed a strong correlation between MVO2 and MBF under a variety of different physiological conditions, from basal to high workload, suggesting an efficient regulation, controlled by changes in blood perfusion or myocardial oxygen supply, and altered oxygen metabolism that produces adequate ATP energy to meet high cardiac workload demands. With further methodology improvements, the 17O-MRSI or 17O-MRI technique promises to provide comprehensive and quantitative measurements of myocardial oxygen metabolism and blood flow, thereby providing oxygen extraction fraction in normal and diseased states, with the potential to translate to human cardiac imaging applications.
ACKNOWLEDGMENTS
This work was in part supported by the National Institutes of Health grants R01 MH111413, R01 NS133006, and P41 EB027061; and the W. M. Keck Foundation. The authors thank Yi Zhang for performing animal preparation and monitoring physiology condition, and Dr. Wei Zhu for assistance in generating tissue H217O maps.
Footnotes
CONFLICT OF INTEREST
The authors don’t have conflicts of interest.
REFERENCES
- 1.Sosnovik DE, Scherrer-Crosbie M. Biomedical imaging in experimental models of cardiovascular disease. Circ Res. 2022;130:1851–1868. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.van de Weijer T, Paiman EHM, Lamb HJ. Cardiac metabolic imaging: current imaging modalities and future perspectives. J Appl Physiol. 2018;124:168–181. [DOI] [PubMed] [Google Scholar]
- 3.Iida H, Rhodes CG, Araujo LI, et al. Noninvasive quantification of regional myocardial metabolic rate for oxygen by use of 15O2 inhalation and positron emission tomography. Theory, error analysis, and application in humans. Circulation. 1996;94:792–807. [DOI] [PubMed] [Google Scholar]
- 4.Yamamoto Y, de Silva R, Rhodes CG, et al. Noninvasive quantification of regional myocardial metabolic rate of oxygen by 15O2 inhalation and positron emission tomography. Experimental validation. Circulation. 1996;94:808–816. [DOI] [PubMed] [Google Scholar]
- 5.Levin CS, Hoffman EJ. Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution. Phys Med Biol. 1999;44:781–799. [DOI] [PubMed] [Google Scholar]
- 6.Zanzonico P Positron emission tomography: a review of basic principles, scanner design and performance, and current systems. Semin Nucl Med. 2004;34:87–111. [DOI] [PubMed] [Google Scholar]
- 7.Zhu XH, Chen JM, Tu TW, Chen W, Song SK. Simultaneous and noninvasive imaging of cerebral oxygen metabolic rate, blood flow and oxygen extraction fraction in stroke mice. Neuroimage. 2013;64:437–447. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Zhu XH, Chen W. In vivo 17O MRS imaging-quantitative assessment of regional oxygen consumption and perfusion rates in living brain. Anal Biochem. 2017;529:171–178. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Zhu XH, Zhang Y, Tian RX, et al. Development of 17O NMR approach for fast imaging of cerebral metabolic rate of oxygen in rat brain at high field. Proc Natl Acad Sci U S A. 2002;99:13194–13199. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Zhu XH, Zhang N, Zhang Y, Ugurbil K, Chen W. New insights into central roles of cerebral oxygen metabolism in the resting and stimulus-evoked brain. J Cereb Blood Flow Metab. 2009;29:10–18. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Kurzhunov D, Borowiak R, Reisert M, Ozen AC, Bock M. Direct estimation of 17O MR images (DIESIS) for quantification of oxygen metabolism in the human brain with partial volume correction. Magn Reson Med. 2018; 80:2717–2725. [DOI] [PubMed] [Google Scholar]
- 12.Niesporek SC, Umathum R, Lommen JM, et al. Reproducibility of CMRO2 determination using dynamic 17O MRI. Magn Reson Med. 2018;79:2923–2934. [DOI] [PubMed] [Google Scholar]
- 13.Atkinson IC, Thulborn KR. Feasibility of mapping the tissue mass corrected bioscale of cerebral metabolic rate of oxygen consumption using 17-oxygen and 23-sodium MR imaging in a human brain at 9.4 T. Neuroimage. 2010;51:723–733. [DOI] [PubMed] [Google Scholar]
- 14.Zhu XH, Wiesner HM, Lee BY, Lu M, Chen W. Quantitative and simultaneous imaging of CMRO2, CBF and OEF in resting human brain. Proceedings of the International Society for Magnetic Resonance in Medicine. ISMRM; 2015:895. [Google Scholar]
- 15.Mateescu GD, Yvars GM, Dular T. In: Lauger P, Packer L, Vasilescu V, eds. Water, Ions and O-17 Magnetic Resonance Imaging. Birkhauser Verlag; 1988. [Google Scholar]
- 16.Zhu XH, Zhang Y, Wiesner HM, Ugurbil K, Chen W. In vivo measurement of CBF using 17O NMR signal of metabolically produced H217O as a perfusion tracer. Magn Reson Med. 2013;70:309–314. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Mitchell HH, Hamilton TS, Steggerda FR, Bean HW. The chemical composition of the adult human body and its bearing on the biochemistry of growth. J Biol Chem. 1945;158:625–637. [Google Scholar]
- 18.Zhang N, Zhu XH, Lei H, Ugurbil K, Chen W. Simplified methods for calculating cerebral metabolic rate of oxygen based on 17O magnetic resonance spectroscopic imaging measurement during a short 17O2 inhalation. J Cereb Blood Flow Metab. 2004;24:840–848. [DOI] [PubMed] [Google Scholar]
- 19.Hoffman WE, Albrecht RF, Miletich DJ. Cerebrovascular response to hypoxia in young vs aged rats. Stroke. 1984;15:129–133. [DOI] [PubMed] [Google Scholar]
- 20.Garwood M, Schleich T, Bendall MR, Pegg DT. Improved fourier series windows for localization in in vivo NMR spectroscopy. J Magn Reson. 1985;65:510–515. [Google Scholar]
- 21.Hendrich K, Hu X, Menon RS, et al. Spectroscopic imaging of circular voxels with a two-dimensional Fourier-series window technique. J Magn Reson B. 1994;105:225–232. [DOI] [PubMed] [Google Scholar]
- 22.Cui W, Zhu XH, Vollmers ML, et al. Non-invasive measurement of cerebral oxygen metabolism in the mouse brain by ultra-high field 17O MR spectroscopy. J Cereb Blood Flow Metab. 2013;33:1846–1849. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Wiesner HM, Balla DZ, Scheffler K, et al. Quantitative and simultaneous measurement of oxygen consumption rates in rat brain and skeletal muscle using 17O MRS imaging at 16.4T. Magn Reson Med. 2020;85:2232–2246. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Pascual F, Coleman RA. Fuel availability and fate in cardiac metabolism: a tale of two substrates. Biochim Biophys Acta. 2016;1861:1425–1433. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Ritterhoff J, Tian R. Metabolism in cardiomyopathy: every substrate matters. Cardiovasc Res. 2017;113:411–421. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Stanley WC, Recchia FA, Lopaschuk GD. Myocardial substrate metabolism in the normal and failing heart. Physiol Rev. 2005;85:1093–1129. [DOI] [PubMed] [Google Scholar]
- 27.Neely JR, Morgan HE. Relationship between carbohydrate and lipid metabolism and the energy balance of heart muscle. Annu Rev Physiol. 1974;36:413–459. [DOI] [PubMed] [Google Scholar]
- 28.Kolwicz SC Jr, Purohit S, Tian R. Cardiac metabolism and its interactions with contraction, growth, and survival of cardiomyocytes. Circ Res. 2013;113:603–616. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Zhu XH, Qiao H, Du F, et al. Quantitative imaging of energy expenditure in human brain. Neuroimage. 2012;60:2107–2117. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Duncker DJ, Bache RJ. Regulation of coronary blood flow during exercise. Physiol Rev. 2008;88:1009–1086. [DOI] [PubMed] [Google Scholar]
- 31.Boudina S, Sena S, Theobald H, et al. Mitochondrial energetics in the heart in obesity-related diabetes: direct evidence for increased uncoupled respiration and activation of uncoupling proteins. Diabetes. 2007;56:2457–2466. [DOI] [PubMed] [Google Scholar]
- 32.Mintun MA, Raichle ME, Martin WR, Herscovitch P. Brain oxygen utilization measured with O-15 radiotracers and positron emission tomography. J Nucl Med. 1984;25:177–187. [PubMed] [Google Scholar]
- 33.Lu M, Zhang Y, Ugurbil K, Chen W, Zhu XH. In vitro and in vivo studies of 17O NMR sensitivity at 9.4 and 16.4 T. Magn Reson Med. 2013;69:1523–1527. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Zhu XH, Merkle H, Kwag JH, Ugurbil K, Chen W. 17O relaxation time and NMR sensitivity of cerebral water and their field dependence. Magn Reson Med. 2001;45:543–549. [DOI] [PubMed] [Google Scholar]
- 35.Piao Y, Liu Y, Xie X. Change trends of organ weight background data in Sprague Dawley rats at different ages. J Toxicol Pathol. 2013;26:29–34. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Lu M, Atthe B, Mateescu GD, Flask CA, Yu X. Assessing mitochondrial respiration in isolated hearts using 17O MRS. NMR Biomed. 2012;25:883–889. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Heinonen I, Kudomi N, Kemppainen J, et al. Myocardial blood flow and its transit time, oxygen utilization, and efficiency of highly endurance-trained human heart. Basic Res Cardiol. 2014;109:413. [DOI] [PubMed] [Google Scholar]
- 38.Kudomi N, Kalliokoski KK, Oikonen VJ, et al. Myocardial blood flow and metabolic rate of oxygen measurement in the right and left ventricles at rest and during exercise using 15O-labeled compounds and PET. Front Physiol. 2019;10:741. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.McKeever WP, Gregg DE, Canney PC. Oxygen uptake of the nonworking left ventricle. Circ Res. 1958;6:612–623. [DOI] [PubMed] [Google Scholar]
- 40.Weiss HR, Neubauer JA, Lipp JA, Sinha AK. Quantitative determination of regional oxygen consumption in the dog heart. Circ Res. 1978;42:394–401. [DOI] [PubMed] [Google Scholar]
- 41.Zhang J, Gong G, Ye Y, et al. Nitric oxide regulation of myocardial O2 consumption and HEP metabolism. Am J Physiol Heart Circ Physiol. 2005;288:H310–H316. [DOI] [PubMed] [Google Scholar]
- 42.Bateman TM, Heller GV, Beanlands R, et al. Practical guide for interpreting and reporting cardiac PET measurements of myocardial blood flow: an information statement from the American Society of Nuclear Cardiology, and the Society of Nuclear Medicine and Molecular Imaging. J Nucl Cardiol. 2021;28:768–787. [DOI] [PubMed] [Google Scholar]
- 43.Kajander SA, Joutsiniemi E, Saraste M, et al. Clinical value of absolute quantification of myocardial perfusion with 15O-water in coronary artery disease. Circ Cardiovasc Imaging. 2011;4:678–684. [DOI] [PubMed] [Google Scholar]
- 44.Pauw MD, Melin J, Buyzere MD, Heyndrickx GR. Myocardial oxidative metabolism, blood flow and efficiency in rapid pacing induced heart failure in dogs. Int J Physiol Pathophysiol Pharmacol. 2014;6:209–215. [PMC free article] [PubMed] [Google Scholar]
- 45.Herrero P, Kim J, Sharp TL, et al. Assessment of myocardial blood flow using 15O-water and 1-11C-acetate in rats with small-animal PET. J Nucl Med. 2006;47:477–485. [PubMed] [Google Scholar]
- 46.Iltis I, Kober F, Dalmasso C, Lan C, Cozzone PJ, Bernard M. In vivo assessment of myocardial blood flow in rat heart using magnetic resonance imaging: effect of anesthesia. J Magn Reson Imaging. 2005;22:242–247. [DOI] [PubMed] [Google Scholar]
- 47.Oshita A, Ohmori K, Yu Y, et al. Myocardial blood flow measurements in rats with simple pulsing contrast echocardiography. Ultrasound Med Biol. 2002;28:459–466. [DOI] [PubMed] [Google Scholar]
- 48.Troalen T, Capron T, Bernard M, Kober F. In vivo characterization of rodent cyclic myocardial perfusion variation at rest and during adenosine-induced stress using cine-ASL cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2014;16:18. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Iida H, Kanno I, Takahashi A, et al. Measurement of absolute myocardial blood flow with H215O and dynamic positron-emission tomography. Strategy for quantification in relation to the partial-volume effect. Circulation. 1988;78:104–115. [DOI] [PubMed] [Google Scholar]
- 50.Iida H, Rhodes CG, de Silva R, et al. Myocardial tissue fraction–correction for partial volume effects and measure of tissue viability. J Nucl Med. 1991;32:2169–2175. [PubMed] [Google Scholar]
- 51.Wang T, Zhu XH, Li H, et al. Noninvasive assessment of myocardial energy metabolism and dynamics using in vivo deuterium MRS imaging. Magn Reson Med. 2021;86:2899–2909. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52.Li Y, Zhao Y, Guo R, et al. Machine learning-enabled high-resolution dynamic deuterium MR spectroscopic imaging. IEEE Trans Med Imaging. 2021;40:3879–3890. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53.Borowiak R, Groebner J, Haas M, Hennig J, Bock M. Direct cerebral and cardiac 17O-MRI at 3 tesla: initial results at natural abundance. Magma. 2014;27:95–99. [DOI] [PubMed] [Google Scholar]
- 54.McCommis KS, He X, Abendschein DR, Gupte PM, Gropler RJ, Zheng J. Cardiac 17O MRI: toward direct quantification of myocardial oxygen consumption. Magn Reson Med. 2010;63:1442–1447. [DOI] [PMC free article] [PubMed] [Google Scholar]
