Skip to main content
Global Cardiology Science & Practice logoLink to Global Cardiology Science & Practice
. 2024 Mar 3;2024(2):e202412. doi: 10.21542/gcsp.2024.12

Paclitaxel-eluting stents versus paclitaxel-coated balloons in coronary artery disease: a meta-analysis of randomized controlled trials

Bryan Gervais de Liyis 1,, Made Dhiyo Wiweka Aryaweda 1, Luh Oliva Saraswati Suastika 2
PMCID: PMC11090184  PMID: 38746063

Abstract

The efficacy of drug-coated balloons (DCB) versus drug-eluting stents (DES) for coronary artery disease (CAD) remains inconclusive. Despite paclitaxel’s common use in both DES and DCB, there is a lack of meta-analyses comparing paclitaxel-eluting stents (PES) and paclitaxel-coated balloons (PCB). This meta-analysis aimed to evaluate and compare the outcomes of DES and DCB with paclitaxel. A systematic literature search of the Medline and Cochrane databases yielded six randomized controlled trials with 951 patients (1:1 ratio). Primary endpoints were mortality, target lesion vascularization (TLV), myocardial infarction (MI), target vessel revascularization (TVR), and major adverse cardiovascular events (MACEs). Secondary endpoints included in-device binary stenosis, in-segment binary stenosis, late luminal loss (LLL), post-minimal lumen diameter (MLD), and post-diameter stenosis. Within the study populations, the incidence of previous MI was significantly lower in the PES group than in the PCB group (26.70% vs. 39.22%, OR:0.56, 95% CI [0.41–0.76], p = 0.0002). The meta-analysis results showed that mortality (OR:1.57, 95% CI [0.67–3.66], p = 0.29), TLV (OR:0.74, 95% CI [0.37–1.48], p = 0.39), MI (OR:1.76, 95% CI [0.79–3.88], p = 0.16), TVR (OR:0.76, 95% CI [0.51–1.12], p = 0.16), and MACEs (OR, 1.11; 95% CI [0.48–2.58]; p = 0.81) did not exhibit significant differences between the PES and PCB groups in CAD. Furthermore, in stent or in balloon binary stenosis (OR:0.80, 95% CI [0.34–1.87], p = 0.60), in segment binary stenosis (OR:1.16, 95% CI [0.48–2.80], p = 0.74), LLL (MD:0.03, 95% CI [−0.11 to 0.17], p = 0.65), post MLD (MD:0.04, 95% CI [−0.23 to 0.30], p = 0.77), and post diameter stenosis (MD:−5.48, 95% CI [−13.88 to 2.92], p = 0.20) were similar in both groups. Our comprehensive analysis concludes that both PES and PCB manifest comparable effectiveness and safety in CAD management.

Introduction

Coronary artery disease (CAD) is a chronic disorder characterized by the accumulation of plaque in the coronary arteries, resulting in decreased blood flow to the myocardium, which can lead to angina, heart attack, or even death1. In 2020, approximately 20.1 million adults aged 20 years and above suffered from CAD; of these, 2 out of every 10 deaths from CAD occurred in adults under 65 years of age2. Minimally invasive percutaneous coronary interventions (PCI), including balloon angioplasty and stenting, are frequently used in CAD patients to enhance blood flow and reduce symptoms3. Plain old balloon angioplasty (POBA) is a balloon-tipped catheter used to enlarge the lumen and improve blood flow in the coronary artery at the location of stenosis or blockage4. This operation is relatively noninvasive and frequently accompanied by stenting5. Stenting, on the other hand, involves the insertion of a tiny metal mesh-like device, known as a bare metal stent (BMS), into the coronary artery to keep it open and avoid restenosis. Stenting is often performed following balloon angioplasty to offer additional support to the arterial wall6. BMS and POBA have been associated with several limitations, including restenosis and in-stent thrombosis, which can result in repeat revascularization procedures and decreased long-term clinical outcomes, such as major adverse cardiovascular events (MACE)7–9, Drug-eluting stents (DES) and drug coated balloons (DCB), on the other hand, have been shown to reduce the incidence of restenosis and improve long-term clinical outcomes, thereby reducing the need for repeat revascularization procedures10–13. DES and DCB function by eluting antiproliferative drugs within the coronary artery, which reduces the risk of adverse events. These drugs are designed to reduce smooth muscle cell proliferation, which is a key contributor to restenosis14,15.

The most commonly used drugs in DES are sirolimus, paclitaxel, and everolimus. These drugs are delivered via a polymer coating on the stent surface and slowly elute into the surrounding tissue over time16–18. Likewise, the most commonly used drugs in DCBs are paclitaxel, sirolimus, and zotarolimus19. The advent of DES has garnered substantial attention, with sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES) being among the most thoroughly examined and utilized varieties within this category20. These drugs have mechanisms of action similar to those of BMS21. Previous meta-analyses have compared the outcomes of DCB and DES extensively22,23. Sánchez et al. suggested that the use of DCB for small-vessel CAD treatment resulted in similar rates of target vessel revascularization (TVR) and restenosis compared to DES. The study also noted a lower risk of vessel thrombosis with DCB22. Giacoppo et al. found that using paclitaxel-coated balloon (PCB) for angioplasty was moderately less effective than repeating the procedure with a DES, in terms of reducing target lesion revascularization (TLR) after 3 years. The combination of death, myocardial infarction, or target lesion thrombosis was found to be comparable between both groups23. However, it is important to note that the validity of these studies is at a risk of bias in terms of comparing stents to balloons. Multiple drugs were used in each group of these studies; therefore, this heterogeneity may limit their interpretation and generalizability. These studies utilized different types of drugs in the DES group (paclitaxel, zotarolimus, sirolimus, and everolimus), which introduced significant heterogeneity. Similarly, a meta-analysis conducted by Elgendy et al. compared different drug emitting interventions, paclitaxel-coated balloons, to everolimus-eluting stents. The study showed an increased risk of TVR and TLR with PCB at extended follow-up compared to everolimus-eluting stents (EES), and better late angiographic outcomes with EES24. Paclitaxel is an antiproliferative agent that works by stabilizing the intracellular microtubules, preventing mitosis in the Go-G1 and G2-M phases of the cell cycle, and effectively preventing the prolonged smooth muscle cell proliferation that occurs during in-stent restenosis25,26. Paclitaxel is lipophilic, thus allowing rapid, homogeneously distributed cellular uptake. In addition, the lipophilic properties of paclitaxel have prolonged effects on arterial smooth muscle cells26,27. This property provides a promising application for the coating of balloons in the treatment of CAD27. Stenting also benefits from this property, as studies have shown that PES significantly reduces the need for target vessel revascularization compared to bare metal stents28.

Despite the growing number of studies on DES and DCB, there has been a noticeable absence of meta-analyses specifically comparing PES and PCB. The lack of comparative data makes it challenging for physicians to make informed decisions regarding the best treatment options for their patients. A comparison of PES and PCB is crucial, as paclitaxel, the drug used in both devices, has unique properties that affect performance. A meta-analysis of PES and PCB would provide a comprehensive evaluation of the safety and efficacy of these devices, allowing for the development of clinical guidelines, improved patient selection, and the optimized use of these treatments.

Methods

Study design and inclusion criteria

This study was conducted in accordance with the PRISMA guidelines. The meta-analysis was pre-registered and approved in the PROSPERO database (ID: CRD42023393794) before the initiation of the literature search. The inclusion criteria for this meta-analysis comprised of randomized controlled trials that evaluated the outcomes of PES and PCB in patients diagnosed with CAD. The literature search and data extraction were performed by a single author (B.G.L), and any discrepancies regarding study eligibility were resolved through consensus following review by two additional authors (M.D.W.A, L.O.S.S). The following criteria were employed: the studies had to clearly state the utilization of paclitaxel as the drug in both stents and balloons, direct comparisons of outcomes between PES and PCB were required, data of the studies had to come from registered trials, and the studies had to equally allocate participants (1:1). The use of the allocation ratio in our inclusion criteria, aimed at ensuring a balanced representation of both interventions. This methodological choice was made to minimize potential confounding variables and enhance the comparability of treatment groups, aligning with the primary objective of generating robust and clinically relevant insights. Exclusion criteria included studies that did not follow-up for at least 12 months and did not specify the type of stents or balloons utilized. This study was a retrospective study of published data and thus was exempt from IRB review.

Literature search and selection

A comprehensive and systematic literature search was executed in PubMed, Medline, and Cochrane databases from January 1st, 2009 to January 1st, 2023, with no language restrictions imposed. The search strategy utilized the combination of Medical Subject Headings (MeSH) terms and free-text keywords, including ((((((((((((((Coronary artery disease) OR (CAD)) OR (coronary disease)) OR (coronary heart disease)) OR (ischemic heart disease)) AND (Paclitaxel-Eluting Stents)) OR (PES)) OR (drug-eluting stents)) OR (stents)) OR (Paclitaxel Eluting Stents)) AND (Paclitaxel-Coated Balloons)) OR (PCB)) OR (drug-coated balloons)) OR (balloons)) AND (angiography). Of the 558 published abstracts or manuscripts retrieved, 132 met the pre-defined inclusion criteria, as outlined in the PRISMA flowchart (Figure 1). Further, a manual review of the references of the identified studies was performed to ensure the completeness of the search and identify any additional pertinent literature. Ultimately, six studies were selected for inclusion in the quantitative analysis.

Figure 1. PRISMA flowchart.

Figure 1.

Quality of included studies

A systematic evaluation of the risk of bias was performed using the Cochrane Collaboration’s tool for Risk of Bias Assessment. This tool comprises seven components, which were used to assess the potential sources of bias in each study, including selection, performance, detection, attrition, reporting, and other biases. The overall quality of evidence for each outcome was subjected to a rigorous evaluation for evaluating the quality of evidence in the medical literature.

Data extraction

The demographic, baseline clinical characteristics, and outcome variables of the included studies were systematically extracted. This information included the number of centers and participants, nation, trial registry, age, gender, presenting clinical features, history of clinical symptoms, target lesion characteristics, targeted vessel characteristics, pattern of restenosis, and type of stent or balloon utilized. The procedural details extracted encompassed parameters such as length, diameter, pressure, and inflation time. The outcome data comprised of metrics, including death, TLR, TVR, myocardial infarction (MI), MACEs, late luminal loss (LLL), post-minimal lumen diameter (MLD), post-diameter stenosis, in-stent thrombosis, in-stent binary stenosis, and in-segment stenosis.

Statistical analysis

For binary outcomes, such as death, TLR, TVR, myocardial infarction, MACE, and in-stent binary stenosis, odds ratios (ORs) with 95% confidence intervals (CIs) were estimated. These trial-specific ORs were combined using the DerSimonian and Laird random-effects model, with the estimate of heterogeneity derived from the Mantel-Haenszel model. For continuous outcomes, such as LLL, post-MLD and post-diameter stenosis, the standardized mean difference (SMD) with 95% CIs was used as the summary statistic, and trial-specific data were pooled using the inverse variance random-effects method. The weighted mean difference (MD) and 95% CIs were calculated for continuous outcomes. An algorithm was executed to determine the mean and standard deviation, and the results were graphically depicted in Forest plots. The heterogeneity between studies was assessed using the I2 statistic, and the random-effects model was employed to pool effect sizes if I2 was greater than 50%, otherwise the fixed-effects model was utilized. All statistical analyses were performed using Review Manager software version 5.4.1 (The Nordic Cochrane Centre, The Cochrane Collaboration, Copenhagen, Denmark), and data was considered statistically significant when the p-value was less than 0.05.

Results

Study selection

The reviewed studies were selected using a flow chart established using PRISMA (Figure 1). The initial literature search conducted using PubMed, Medline, and Cochrane databases collected 558 publications. From the collected publications, 26 were identified as duplicates and removed from the study. After applying the inclusion and exclusion criteria, 6 studies were included in meta-analysis19,20,22,23,29,30. In this study, we analyzed several outcomes which includes death, target lesion revascularization, target vessel revascularization, myocardial infarction, late luminal loss, minimal lumen diameter, diameter stenosis, thrombosis, binary stenosis (in stent/balloon) and binary stenosis (in segment).

From the included studies a total of 951 patients were analyzed. The randomized critical trials (RCTs) in this study were assessed using RoB-2 tool by Cochrane. Out of the 6 RCTs analyzed, 5 have a high risk of bias and 1 holds concern, with five studies presenting a high risk of performance bias, one study presenting a high risk of selection bias, and 2 studies presenting a high risk of reporting bias (Figure 2).

Figure 2. Risk of bias graph and risk of bias summary.

Figure 2.

Characteristics of selected studies

Table 1 shows the baseline information and characteristics of the study subjects in each trial. The included studies consist of six trials from four different countries, namely Italy, Germany, Netherlands, and China. These studies were registered by the name PICCOLETO, ISAR DESIRE 3, BELLO, DEB-AMI, PEPCAD II, and PEPCAD CHINA ISR. The PICCOLETO, BELLO, and DEB-AMI trial used the radial and femoral artery as the site of access. On the other hand, the ISAR DESIRE 3 and PEPCAD CHINA ISR trial used the radial artery as the only site of access, while the PEPCAD II trial used the femoral artery as the only site of access. In total, 477 patients were treated using paclitaxel-eluting stents while 474 were treated with paclitaxel-coated balloons, in a roughly 1:1 ratio.

Table 1. Baseline characteristics for each study.

Studies
Cortese, 2010 Kufner, 2015 Latib, 2012 Nijhoff, 2015 Unverdorben, 2009 Xu, 2014
Number of Centers 1 3 15 2 10 17
Country Italy Germany Italy Netherlands Germany China
Trial PICCOLETO (EudraCTCode: 2009-012268-15) ISAR DESIRE 3 (NCT00987324) BELLO (NCT01086579) DEB-AMI (NCT01086579) PEPCAD II (NCT00393315) PEPCAD CHINA ISR (NCT01622075)
Time August 2008 –August 2008 August 2009 –October 2011 March 2010 –March 2012 March 2009 –June 2011 January 2006 -December 2006 March 2011 –April 2012
Access Radial and Femoral Artery Radial Artery Radial and Femoral Artery Radial and Femoral Artery Femoral Artery Radial Artery
Participants S vs B (ratio) 29 vs 28 (1:1) 131 vs 137 (1:1) 97 vs 94 (1:1) 49 vs 40 (1:1) 65 vs 66 (1:1) 106 vs 109 (1:1)
Male Participants S 22 88 71 41 50 86
B 28 137 94 66 109
Stent Type Used Taxus Liberté, Boston Scientific, Natick, Massachusetts Taxus Liberté, Boston Scientific, Natick, Massachusetts Taxus Liberté, Boston Scientific, Natick, Massachusetts Taxus Liberté, Boston Scientific, Natick, Massachusetts Taxus Liberté, Boston Scientific, Natick, Massachusetts Taxus Liberté, Boston Scientific, Natick, Massachusetts
Balloon Type Used Dior PCB (Eurocor, Bonn, Germany) SeQuent Please, B. Braun, Melsungen,Germany IN.PACT Falcon paclitaxel DEB (Medtronic, Inc., Santa Rosa, California) Second generation DIORVR coronary angioplasty balloon (Eurocor GmbH, Bonn, Germany SeQuent Please, B. Braun, Melsungen,Germany SeQuentPlease, B. Braun Melsungen AG, Melsungen, Germany
Mean Age (SD) S 67 (10) 68.8 (10) 66.4 (9) 55.9 (9.7) 65.1 (8.7) 62.1 (9.3)
B 68 (9) 67.7 (10.4) 64.8 (8.5) 57.9 (10) 64.6 (9.7) 61.8 (9.3)
Smoking S 15 10 28 15 27
B 19 15 21 16 23
Hyper-tension S 20 101 75 15 54 69
B 21 105 72 14 53 78
Diabetes S 11 61 35 2 17 35
B 13 56 39 5 22 44
Hyperlipidemia S 13 103 73 16 46 35
B 17 108 71 7 52 38
Previous MI S 6 32 33 2 37
B 5 53 46 3 53
Previous CABG S 4 50 12 0
B 3 15 9 0 3
Multi-vessels S 19 122 56 - 42 22
B 17 129 56 - 47 24

Notes.

Abbreviations
B
Balloon group
S
Stent group
CABG
Coronary artery bypass graft
MI
Myocardial infraction
-
No Data in Study

The average age from the stent and balloon group did not significantly differ from one another 64.22 (9.45) vs 64.13 (9.48) (p = 0.37). Patients in the stent group and the balloon group had no significant difference in gender composition, with both groups being dominated by the male gender, shown by the male percentage of 62.68% vs 76.16% (p = 0.44) respectively. The baseline characteristics were generally found to have no statistically significant difference between the stent and balloon groups (smoking [p = 0.82], hypertension [p = 0.58], diabetes mellitus [p = 0.26], hyperlipidemia [p = 0.91], previous CABG [p = 0.37], multivessels [p = 0.53]) with the exception of previous MI status in which the balloon groups were found to have a significantly higher incidence rate (26.70% vs 39.22%; OR 0.56 [0.41, 0.76]; p = 0.0002). Lesion and procedural data of each study are summarized in Table 2. Meanwhile, the demographic status and baseline characteristics are summarized in Table 3.

Table 2. Lesion and procedural data for each study.

Studies
Cortese, 2010 Kufner, 2015 Latib, 2012 Nijhoff, 2015 Unverdorben, 2009 Xu, 2014
S B S B S B S B S B S B
TV Diagonal 15 15 50 59 20 26 18 18 28 20 61 47
OMA 3 5 62 54 47 35 11 9 19 24 13 21
PDA 11 8 56 39 28 34 20 13 17 22 34 45
TL Reference Diameter 2.58 (0.24) 2.45 (0.28) 2.8 (0.49) 2.75 (0.5) 2.41 (0.4) 2.41 (0.34) 2.78 (0.53) 2.83 (0.51) 2.83 (0.36) 2.85 (0.39) 2.72 (0.44) 2.66 (0.38)
Lesion length 11.38 (7.12) 12.41 (5.89) 10.6 (6.3) 9.6 (5.9) 14.4 (5.6) 15.4 (6.2) 16.8 (8.7) 13 (5.7) 15.4 (6.6) 15.7 (6.6) 13.08 (7.13) 12.52 (6.55)
Lumen Diameter (pre-intervention) 0.4 (0.3) 0.48 (0.33) 0.93 (0.5) 0.97 (0.48) 0.62 (0.22) 0.6 (0.24) 0.34 (0.41) 0.29 (0.5) 0.77 (0.3) 0.74 (0.27) 0.86 (0.41) 0.85 (0.38)
Lumen Diameter (post-intervention) 2.63 (0.23) 2.47 (0.22) 2.29 (0.44) 2.29 (0.44) 1.99 (0.28) 1.56 (0.32) 2.53 (0.41) 2.22 (0.45) 2.11 (0.78) 2.3 (0.4) 1.89 (0.75) 2.39 (0.37)
Diameter Stenosis (Pre-intervention) 89.14 (10.6) 86.0 (12.1) 66.7 (16.5) 64.4 (16.8) 72.78 (9.27) 72.14 (10.05) 88.4 (13.6) 91.1 (15.4) 72.8 (9.4) 73.9 (8.8) 68.43 (13.25) 68.26 (12.47)
Diameter Stenosis (Post-intervention) 9.9 (9.2) 19 (17.3) 18.5 (8.3) 18.5 (8.3) 15.42 (6.92) 29.84 (10.24) 19 (11.6) 38.4 (23.5) 11.2 (8.1) 19.5 (9.9) 27.72 (25.58) 10.51 (7.22)

Notes.

Abbreviations
TV
Target Vessel
TL
Target Lesion
OMA
Obtuse Marginal Artery
PDA
Patent Ductus Arteriosus

Table 3. Difference in basic clinical symptoms.

PES PCB Odds Ratio/Mean Difference [95% CI] p
Mean age 64.22 (9.45) 64.13 (9.48) MD 0.55 [−0.65, 1.76] 0.37
Male 62.68% (299/477) 76.16% (361/474) OR 0.68 [0.26, 1.81] 0.44
Smoking 21.21% (95/448) 21.08% (94/446) OR 0.96 [0.69, 1.35] 0.82
Hypertension 70.02% (334/477) 72.36% (343/474) OR 0.92 [0.69, 1.23] 0.58
Diabetes mellitus 33.75% (161/477) 37.76% (179/474) OR 0.86 [0.65, 1.12] 0.26
Hyperlipidemia 59.96% (286/477) 60.97% (289/474) OR 0.98 [0.74, 1.31] 0.91
Previous MI 26.70% (110/412) 39.22% (160/408) OR 0.56 [0.41, 0.76] 0.0002
Previous CABG 18.18% (66/363) 8.15% (30/368) OR 1.68 [0.54, 5.22] 0.37
Multivessels 60.98% (261/428) 62.90% (273/434) OR 0.90 [0.65, 1.25] 0.53

Notes.

Abbreviations
CABG
Coronary artery bypass graft
MI
Myocardial infraction

Clinical outcomes in PES- vs PCB-treated patients

Clinical outcomes and complications found in the stent and balloon group and comparison between the two are summarized in Table 4. The analysis showed no significant difference in any outcome. Heterogeneity test to the death endpoint showed that there are no differences in the intervention effect across the study with an I2 value of 0% (p = 0.82) (Figure 3). The test of overall effect showed similar results, in which no significant difference between the two interventions were found (Z = 1.05; p = 0.29). All studies included resulted in a non-statistically significant odds ratio between interventions, with total odds ratio crossing the value of 1 (OR = 1.57; CI = 0.67–3.66).

Table 4. Forest plot results summary.

Endpoint PES PCB Odds Ratio/Mean Difference [95% CI] p
Death 2.73% (13/477) 1.69% (8/474) OR 1.57 [0.67, 3.66] 0.29
Target Lesion Revascularization 10.69% (51/477) 14.56% (69/474) OR 0.74 [0.37, 1.48] 0.39
Myocardial Infraction 3.74% (16/428) 2.07% (9/434) OR 1.76 [0.79, 3.88] 0.16
Target Vessel Revascularization 12.86% (53/412) 16.67% (68/408) OR 0.76 [0.51, 1.12] 0.16
Major Adverse Cardiovascular Events 18.66% (89/477) 15.40% (73/474) OR 1.11 [0.48, 2.58] 0.81
Binary Stenosis (in stent/in balloon) 12.43% (43/346) 13.65% (46/337) OR 0.80 [0.34, 1.87] 0.60
Binary Stenosis (in segment) 14.83% (47/317) 12.62% (39/309) OR 1.16 [0.48, 2.80] 0.74
Late Luminal Loss MD 0.03 [−0.11, 0.17] 0.65
Minimal Lumen Diameter (Post) MD 0.04 [−0.23, 0.30] 0.77
Diameter Stenosis (Post) MD -5.48 [−13.88, 2.92] 0.20

Notes.

Abbreviations
PES
Paclitaxel Eluding Stents
PCB
Paclitaxel Coated Balloons

Figure 3. Effects of paclitaxel-eluting stents on (A) mortality, (B) target lesion revascularization, (C) myocardial infraction, (D) target vessel revascularization, (E) major adverse cardiovascular events, (F) in stent or in balloon binary stenosis, (G) in segment binary stenosis, (H) late luminal loss, (I) post minimal lumen diameter, and (J) post diameter stenosis compared with paclitaxel-coated balloons.

Figure 3.

The test for overall effect showed that target lesion revascularization was found to not be significantly different between the intervention groups (Z = 0.85; P = 0.39). All studies included resulted in a non-statistically significant odds ratio between interventions, with total odds ratio crossing the value of 1 (OR = 0.74; CI = 0.37–1.48). Although, different from the death outcome, there was a significant heterogeneity between the findings of each included studies (I2 = 58%; p = 0.04).

In cases of myocardial infarction, homogeneity of findings of the included studies was observed (I2 = 0%; p = 0.64). No significant difference was found between the two interventions (OR = 1.76; CI = 0.79 –3.88). The test for overall effect showed similar results (Z = 1.39; p = 0.16). The DEB-AMI30 trial was not included in the analysis as no data regarding myocardial infarction was presented in the published article.

In terms of target vessel revascularization, paclitaxel-eluting stents and paclitaxel-coated balloons produced statistically similar outcome (OR = 0.76; CI = 0.51, 1.12). The heterogeneity test concluded that results from the included studies were homogenic (I2 = 0%; p = 0.41). The test of overall effect concluded that no statistically significant difference can be observed between the two intervention groups (Z = 1.40; p = 0.16). The PEPCAD II31 trial was not included in the analysis as no data regarding target vessel revascularization was provided.

Major adverse cardiovascular events frequency was found to be statistically similar between the two intervention groups, with odds ratio confidence interval crossing the value of 1 (OR = 1.11; CI = 0.48–2.58). Significant heterogeneity was found in the results of the included studies (I2 = 79%, p = 0.0003). With the exception of the PEPCAD CHINA ISR trial32, all included studies showed insignificant differences between interventions. The PEPCAD CHINA ISR study found that paclitaxel-eluting stents have a higher odds of MACE than paclitaxel-coated balloons32. Regardless, the test of overall effect showed no significant difference between the two interventions (Z = 0.24; p = 0.81).

The odds of binary stenosis happening in stent and in balloon were found to be statistically similar between the two interventions (OR = 0.80; CI = 0.34–1.87). However, this finding was not homogenic across the included studies (I2 = 65%; p = 0.02). Unlike the other 4 included studies, the DEB-AMI trial30 showed that patients in the paclitaxel-eluting stents group have a lower odds of developing in stent binary stenosis compared to their counterpart (OR = 0.17; CI = 0.03–0.85). Following the trend of other measured outcomes, the test for overall effect showed no significant difference between the two interventions (Z = 0.52; p = 0.60). The ISAR DESIRE 3 trial29 was not included in the analysis as no data regarding the in stent and in balloon stenosis event was recorded in the published article.

In segment binary stenosis events, frequency does not differ significantly between the interventions (OR = 1.16; CI = 0.48–2.80). Heterogeneity test results showed that not all included studies have the same conclusions (I2 = 67%; p = 0.03). The PEPCAD II31 concluded that patients treated with paclitaxel-eluding stents have a higher odds of developing in-segment binary stenosis compared to their counterparts. Nevertheless, the test for overall effect concluded that no significant difference is present between the two interventions regarding the in segment binary stenosis events (Z = 0.34; p = 0.74). The ISAR DESIRE 3 trial29 and the PICCOLETO trial33 were not included in the analysis as the published articles lacks data regarding in segment binary stenosis event.

Late luminal loss amount does not differ significantly between interventions as analysis showed that the mean difference’s confidence interval crosses zero (MD = 0.03 mm; CI = −0.11–0.17 mm). This finding is not homogenous, as shown by the heterogeneity test (I2 = 74%; p = 0.004). The PEPCAD II trial31 mentioned a mean difference of 0.21 mm with the confidence interval ranging from 0.03 to 0.39 mm, making it the only included study which confidently concludes that difference in late luminal loss is significantly present between the intervention. Nonetheless, the test for overall effect showed no significant difference between the two groups (Z = 0.45; p = 0.65). The PICCOLETO trial33 was not included in this analysis as the published article lacked data regarding late luminal loss.

The post-intervention minimal lumen diameters are not significantly different between the two interventions with confidence interval of the mean difference crossing zero (MD = 0.04 mm; CI = −0.23–0.30 mm). The findings from the 6 included studies are very heterogenic (I2 = 96%; p < 0.00001), with 2 studies29,31 showing no significant difference between the interventions, 3 studies30,33,34 showing wider diameter in favor of the paclitaxel-eluting stents group, and a study32 showing wider diameter in favor of the paclitaxel-coated balloons group. Nevertheless, the test for overall effect concluded that the two intervention groups does not differ significantly (Z = 0.29; p = 0.77).

Post-intervention percent diameter stenosis was found to be statistically similar when calculated in total (MD = −5.48%; CI = −13.88–2.92). Similar to post-intervention luminal loss, high heterogeneity was found regarding the percent diameter stenosis outcome of each study (I2 = 97%; p < 0.00001), in which 4 studies30,31,33,34 concluded that patients treated with paclitaxel-eluting stents have a lower post-intervention percent diameter stenosis, one study found no significant difference between the two groups29, and one study32 found that patients treated paclitaxel-coated balloons have a lower post intervention percent diameter stenosis. Following the trend of the other clinical outcomes, test for overall effect found no significant difference between the two interventions (Z = 1.28; p = 0.20).

Discussion

Careful consideration of the type and location of the stenosis or occlusion, as well as the overall health and medical history of the patient, is essential in determining the best treatment strategy for PCI. Our meta-analysis found homogenic, non-significant difference in the outcome of death, target vessel revascularization, and myocardial infarction events. This indicated that PES and PCB are equally effective at preventing said events in patients with coronary artery disease. This finding is consistent with the findings of a previous meta-analysis conducted by Li et al. 26, which concluded that drug-coated balloon is noninferior to drug-eluting stent in terms of delivering a good outcome in nonfatal myocardial infarction in patients with de novo small coronary artery vessel disease. Similar results were found in the meta-analysis performed by Elgendy et al. 24, which concluded that PCB was associated with similar risk of target vessel revascularization at 1-year follow up in patients with ISR.

On the other hand, highly heterogeneous results were found in the outcomes regarding TLR, MACE, binary stenosis (both in stent/balloon and in segment), late luminal loss, and minimal lumen diameter and diameter stenosis, both of which reached p values of <0.00001 and I2 of 96% and 97%, respectively. The high heterogeneity might have been caused by the difference in the race composition of the patients included in each included study in this meta-analysis. Different races, such as white, black, Hispanic, and Asian, have been shown to have significantly different outcomes with regard to major adverse cardiac event rates, even after adjusting for differences in baseline characteristics35. Thus, it is advisable to conduct additional research to explore the potential role of race in determining the outcomes of both PES and PCB.

Another important factor that should be considered is the different types of balloons used in each included study. The ISAR DESIRE 329, PEPCAD II31, and PEPCAD CHINA32 trials used the SeQuent® Please catheter, the PICCOLETO trial33 used the DIOR® Paclitaxel-eluting coronary balloon catheter, the DEB-AMI trial30 used the second-generation DIOR Paclitaxel-eluting coronary balloon catheter, and the BELLO trial34 used the IN. PACT™ Admiral™ Paclitaxel-coated PTA Balloon Catheter.

DIOR and Sequent catheters use different coating technologies. The former achieves paclitaxel delivery by coating it on a roughened surface of the balloon, whereas the latter achieves paclitaxel delivery by sticking paclitaxel into a water-soluble matrix.

The SeQuent® Please technology allows for higher bioavailability as the drug is released completely after the first expansion33. We found that trials using the SeQuent® Please catheter resulted in an odds ratio in favor of PCB in the MI, stent or balloon binary stenosis, segment binary stenosis, and mortality outcome, while resulting in favor of PES in the post-intervention minimum lumen diameter, late luminal loss, and target vessel revascularization.

However, it is important to note that most of these results are not statistically conclusive since the confidence interval crosses the value of one. In addition, we found that the BELLO study34, the only included study using the IN.PACT™ Admiral™ Paclitaxel-coated PTA Balloon Catheter, which uses urea as the inactive ingredient to facilitate the release and transfer of paclitaxel, was the only study which resulted in favor of PCB in the TVR outcome, although the result is not statistically conclusive as the confidence interval still crossed the value of one.

This trial also favored PCB in 8 other outcomes, namely MI, TVR, TVL, MACE, stent or balloon binary stenosis, segment binary stenosis, post-intervention late luminal loss, and minimal lumen diameter, with the last outcome being the only significantly conclusive result.

Several limitations must be acknowledged when interpreting the results of our meta-analysis. First, the included trials varied in design, patient population, and follow-up duration, potentially introducing heterogeneity. Additionally, the relatively small sample size of the selected studies may limit the generalizability of our findings. Furthermore, the paucity of long-term data on outcomes such as late stent thrombosis or restenosis rates necessitates the cautious interpretation of our conclusions beyond the observed follow-up periods. Moreover, our study included trials with various catheters used for PCB, which allowed for bias based on the individual performance of each catheter. In addition, high heterogeneity in some of the observed outcomes may require clinicians to approach the conclusions of this meta-analysis in the general population more carefully. Despite these limitations, our meta-analysis provides valuable insights into current evidence comparing PES and PCB in the context of CAD.

Conclusions

Our meta-analysis aimed to compare the clinical outcomes of PES and PCB use in patients with CAD. We analyzed death, target vessel revascularization, target lesion revascularization, MACE, myocardial infarction, in stent/balloon binary stenosis, in segment binary stenosis, late luminal loss, minimal lumen diameter, and diameter stenosis outcomes. We found no significant difference between the two interventions in all outcomes, despite the highly heterogeneous results. This finding implies that PCB and PES are similarly effective in terms of efficacy and safety in the treatment of CAD.

Conflict of Interest

The authors declare no potential conflicts of interest with respect to the research, authorship, or publication of this article.

Acknowledgements

No other acknowledgements

Sources of Funding

This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors

Author Contributions

Conceptualization: Bryan Gervais de Liyis

Supervision: Bryan Gervais de Liyis and Luh Oliva Saraswati Suastika

Software: Bryan Gervais de Liyis

Writing -Original Draft Preparation: Made Dhiyo Wiweka Aryaweda

Writing -Review & Editing: Made Dhiyo Wiweka Aryaweda, and Luh Oliva Saraswati Suastika

References

  • 1.Shahjehan RD, Bhutta BS. Coronary artery disease. StatPearls; Treasure Island (FL): 2022. [PubMed] [Google Scholar]
  • 2.Tsao CW, Aday AW, Almarzooq ZI, Alonso A, Beaton AZ, Bittencourt MS, et al. Heart disease and stroke statistics—2022 update: A report from the American heart association. Circulation [Internet] 2022;145(8):e153–639. doi: 10.1161/CIR.0000000000001052. Available from: [DOI] [PubMed] [Google Scholar]
  • 3.Ahmad M, Mehta P, Reddivari AKR, Mungee S. Percutaneous coronary intervention. StatPearls; Treasure Island (FL): 2022. [PubMed] [Google Scholar]
  • 4.Byrne RA, Stone GW, Ormiston J, Kastrati A. Coronary balloon angioplasty, stents, and scaffolds. Lancet [Internet] 2017;390(10096):781–92. doi: 10.1016/S0140-6736(17)31927-X. Available from: [DOI] [PubMed] [Google Scholar]
  • 5.Sfyroeras GS, Karathanos C, Antoniou GA, Saleptsis V, Giannoukas AD. A meta-analysis of combined endarterectomy and proximal balloon angioplasty for tandem disease of the arch vessels and carotid bifurcation. J Vasc Surg. 2011;54(2):534–40. doi: 10.1016/j.jvs.2011.04.022. [DOI] [PubMed] [Google Scholar]
  • 6.Bonaventura A, Montecucco F, Liberale L. Coronary stenting: A matter of revascularization. World journal of cardiology. 2017;9:207–11. doi: 10.4330/wjc.v9.i3.207. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Alfonso F, Cuesta J. The therapeutic dilemma of recurrent in-stent restenosis. Circ Cardiovasc Interv [Internet] 2018;11(8):e007109. doi: 10.1161/CIRCINTERVENTIONS.118.007109. Available from: [DOI] [PubMed] [Google Scholar]
  • 8.Yang J, Mamuti W, Zhang F. Optimal interventional strategy for the treatment of coronary in-stent restenosis. J Thorac Dis. 2015;7(10) doi: 10.3978/j.issn.2072-1439.2015.10.13. Available from: https://jtd.amegroups.com/article/view/5498. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Paramasivam G, Devasia T, Ubaid S, Shetty A, Nayak K, Pai U, et al. In-stent restenosis of drug-eluting stents: Clinical presentation and outcomes in a real-world scenario. Egypt Hear J [Internet] 2019;71(1):28. doi: 10.1186/s43044-019-0025-z. Available from: [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Mohiaddin H, Wong TDFK, Burke-Gaffney A, Bogle RG. Drug-coated balloon-only percutaneous coronary intervention for the treatment of De Novo coronary artery disease: A systematic review. Cardiol Ther [Internet] 2018;7(2):127–49. doi: 10.1007/s40119-018-0121-2. Available from: [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Hao X, Huang D, Wang Z, Zhang J, Liu H, Lu Y. Study on the safety and effectiveness of drug-coated balloons in patients with acute myocardial infarction. J Cardiothorac Surg [Internet] 2021;16(1):178. doi: 10.1186/s13019-021-01525-8. Available from: [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Sarno G, Lagerqvist B, Fröbert O, Nilsson J, Olivecrona G, Omerovic E, et al. Lower risk of stent thrombosis and restenosis with unrestricted use of ‘new-generation’ drug-eluting stents: A report from the nationwide Swedish Coronary Angiography and Angioplasty Registry (SCAAR) Eur Heart J [Internet] 2012;33(5):606–13. doi: 10.1093/eurheartj/ehr479. Available from: [DOI] [PubMed] [Google Scholar]
  • 13.Kiramijyan S, Liu MW. The benefits of drug-eluting stents in the treatment of coronary artery disease. Res Reports Clin Cardiol. 2016;16(7):9–25. [Google Scholar]
  • 14.Marx SO, Totary-Jain H, Marks AR. Vascular smooth muscle cell proliferation in restenosis. Circ Cardiovasc Interv. 2011;4(1):104–11. doi: 10.1161/CIRCINTERVENTIONS.110.957332. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Buglak NE, Jiang W, Bahnson ESM. Cinnamic aldehyde inhibits vascular smooth muscle cell proliferation and neointimal hyperplasia in Zucker Diabetic Fatty rats. Redox Biol. 2018;19:166–78. doi: 10.1016/j.redox.2018.08.013. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Kimura T, Morimoto T, Natsuaki M, Shiomi H, Igarashi K, Kadota K, et al. Comparison of everolimus-eluting and sirolimus-eluting coronary stents. Circulation [Internet] 2012;126(10):1225–36. doi: 10.1161/CIRCULATIONAHA.112.104059. Available from: [DOI] [PubMed] [Google Scholar]
  • 17.Lee MS, Mahmud E, Ang L, Lluri G, Cheng RK, Aragon J, et al. Comparison of sirolimus-, paclitaxel-, and everolimus-eluting stent in unprotected left main coronary artery percutaneous coronary intervention. J Saudi Hear Assoc. 2013;25(2):75–8. doi: 10.1016/j.jsha.2013.03.001. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Kaul U, Bangalore S, Seth A, Arambam P, Abhaichand RK, Patel TM, et al. Paclitaxel-eluting versus everolimus-eluting coronary stents in diabetes. N Engl J Med [Internet] 2015;373(18):1709–19. doi: 10.1056/NEJMoa1510188. Available from: [DOI] [PubMed] [Google Scholar]
  • 19.Jeger RV, Eccleshall S, Wan Ahmad WA, Ge J, Poerner TC, Shin ES, et al. Drug-coated balloons for coronary artery disease: Third report of the international DCB Consensus group. JACC Cardiovasc Interv [Internet] 2020;13(12):1391–402. doi: 10.1016/j.jcin.2020.02.043. Available from: https://www.sciencedirect.com/science/article/pii/S1936879820308244. [DOI] [PubMed] [Google Scholar]
  • 20.Zhang X, Xie J, Li G, Chen Q, Xu B. Head-to-head comparison of sirolimus-eluting stents versus paclitaxel-eluting stents in patients undergoing percutaneous coronary intervention: A meta-analysis of 76 studies. PLoS One [Internet] 2014;9(5):e97934. doi: 10.1371/journal.pone.0097934. Available from: [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Kolachalama VB, Pacetti SD, Franses JW, Stankus JJ, Zhao HQ, Shazly T, et al. Mechanisms of tissue uptake and retention in zotarolimus-coated balloon therapy. Circulation [Internet] 2013;127(20):2047–55. doi: 10.1161/CIRCULATIONAHA.113.002051. Available from: [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Sanz Sánchez J, Chiarito M, Cortese B, Moretti A, Pagnotta P, Reimers B, et al. Drug-coated balloons vs drug-eluting stents for the treatment of small coronary artery disease: A meta-analysis of randomized trials. Catheter Cardiovasc Interv [Internet] 2021;98(1):66–75. doi: 10.1002/ccd.29111. Available from: [DOI] [PubMed] [Google Scholar]
  • 23.Giacoppo D, Alfonso F, Xu B, Claessen BEPM, Adriaenssens T, Jensen C, et al. Paclitaxel-coated balloon angioplasty vs. drug-eluting stenting for the treatment of coronary in-stent restenosis: A comprehensive, collaborative, individual patient data meta-analysis of 10 randomized clinical trials (DAEDALUS study) Eur Heart J. 2020;41(38):3715–28. doi: 10.1093/eurheartj/ehz594. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Elgendy IY, Mahmoud AN, Elgendy AY, Mojadidi MK, Elbadawi A, Eshtehardi P, et al. Drug-eluting balloons versus everolimus-eluting stents for in-stent restenosis: A meta-analysis of randomized trials. Cardiovasc Revasc Med. 2019;20(7):612–8. doi: 10.1016/j.carrev.2018.08.010. [DOI] [PubMed] [Google Scholar]
  • 25.Mark K, Tuttle M, Jeffrey J, Popma M. A retrospective look at paclitaxel use in the coronary arteries. Endovasc Today. 2019;18(9):80–4. [Google Scholar]
  • 26.El-Mokadem M, El-Ramly M, Hassan A, Boshra H, AbdelWahab A. Comparison between catheter-based delivery of paclitaxel after bare-metal stenting and drug-eluting stents in coronary artery disease patients at high risk for in-stent restenosis. Cardiovasc Revascularization Med. 2017;18(8):596–600. doi: 10.1016/j.carrev.2017.05.018. [DOI] [PubMed] [Google Scholar]
  • 27.Yerasi C, Case BC, Forrestal BJ, Torguson R, Weintraub WS, Garcia-Garcia HM, et al. Drug-coated balloon for De Novo coronary artery disease: JACC state-of-the-art review. J Am Coll Cardiol. 2020;75(9):1061–73. doi: 10.1016/j.jacc.2019.12.046. [DOI] [PubMed] [Google Scholar]
  • 28.Palmerini T, Biondi-Zoccai G, Della Riva D, Mariani A, Genereux P, Branzi A, et al. Stent thrombosis with drug-eluting stents: Is the paradigm shifting? J Am Coll Cardiol. 2013;62(21):1915–21. doi: 10.1016/j.jacc.2013.08.725. [DOI] [PubMed] [Google Scholar]
  • 29.Kufner S, Cassese S, Valeskini M, Neumann FJ, Schulz-Schüpke S, Hoppmann P, et al. Long-term efficacy and safety of paclitaxel-eluting balloon for the treatment of drug-eluting stent restenosis: 3-year results of a randomized controlled trial. JACC Cardiovasc Interv. 2015;8(7):877–84. doi: 10.1016/j.jcin.2015.01.031. [DOI] [PubMed] [Google Scholar]
  • 30.Nijhoff F, Agostoni P, Belkacemi A, Nathoe HM, Voskuil M, Samim M, et al. Primary percutaneous coronary intervention by drug-eluting balloon angioplasty: The nonrandomized fourth arm of the DEB-AMI (drug-eluting balloon in ST-segment elevation myocardial infarction) trial. Catheter Cardiovasc Interv. 2015;86:S34–44. doi: 10.1002/ccd.26060. [DOI] [PubMed] [Google Scholar]
  • 31.Unverdorben M, Vallbracht C, Cremers B, Heuer H, Hengstenberg C, Maikowski C, et al. Paclitaxel-coated balloon catheter versus paclitaxel-Coated stent for the treatment of coronary in-stent restenosis. Circulation. 2009;119(23):2986–94. doi: 10.1161/CIRCULATIONAHA.108.839282. [DOI] [PubMed] [Google Scholar]
  • 32.Xu B, Gao R, Wang J, Yang Y, Chen S, Liu B, et al. A prospective, multicenter, randomized trial of paclitaxel-coated balloon versus paclitaxel-eluting stent for the treatment of drug-eluting stent in-stent restenosis: Results from the PEPCAD China ISR trial. JACC Cardiovasc Interv. 2014;7(2):204–11. doi: 10.1016/j.jcin.2013.08.011. [DOI] [PubMed] [Google Scholar]
  • 33.Cortese B, Micheli A, Picchi A, Coppolaro A, Bandinelli L, Severi S, et al. Paclitaxel-coated balloon versus drug-eluting stent during PCI of small coronary vessels, a prospective randomised clinical trial. The PICCOLETO study. Heart. 2010;96(16):1291–6. doi: 10.1136/hrt.2010.195057. [DOI] [PubMed] [Google Scholar]
  • 34.Latib A, Colombo A, Castriota F, Micari A, Cremonesi A, De Felice F, et al. A randomized multicenter study comparing a paclitaxel drug-eluting balloon with a paclitaxel-eluting stent in small coronary vessels: The bello (balloon elution and late loss optimization) study. J Am Coll Cardiol. 2012;60(24):2473–80. doi: 10.1016/j.jacc.2012.09.020. [DOI] [PubMed] [Google Scholar]
  • 35.Golomb M, Redfors B, Crowley A, Smits PC, Serruys PW, von Birgelen C, et al. Prognostic impact of race in patients undergoing PCI: Analysis from 10 randomized coronary stent trials. Cardiovasc Interv. 2020;13(13):1586–95. doi: 10.1016/j.jcin.2020.04.020. [DOI] [PubMed] [Google Scholar]

Articles from Global Cardiology Science & Practice are provided here courtesy of Magdi Yacoub Institute

RESOURCES