EUS-guided hepaticoduodenostomy (EUS-HDS) is rarely indicated for right hepatic obstruction due to failed endoscopic retrograde cholangiopancreatography.[1–3] Compared with EUS-guided hepaticogastrostomy, the risk of obstruction of the anterior or posterior bile duct should be considered. A plastic stent may overcome this concern but has the drawback of short stent patency. EUS-HDS can normally be performed from the posterior bile duct, but the posterior bile duct can sometimes run at an acute angle. In addition, to prevent bile leakage, plastic stent deployment without tract dilation is recommended. Therefore, the stent must have both flexible and stiff properties during EUS-HDS. A novel plastic stent (REGULUS Biliary Tube Stent System; Japan Lifeline Co, Ltd, Tokyo, Japan) has recently become available in Japan [Figure 1]. The tip of this stent is tapered, and the inner lumen is coated by polytetrafluoroethylene to reduce the rate of stent obstruction due to sludge. This stent is stiff, but becomes flexible in vivo. We herein report successful EUS-HDS using this stent.
Figure 1.

The novel plastic stent (7F, REGULUS Biliary Tube Stent System; Japan Lifeline Co, Ltd, Tokyo, Japan).
A 77-year-old man underwent middle common bile duct resection due to bile duct cancer. After 6 months, recurrence of biliary cancer was observed at the posterior bile duct. Because of the complication of frequent focal cholangitis, EUS-HDS was attempted. First, the posterior bile duct was punctured using a 19-gauge needle [Figure 2], cholangiography was obtained [Figure 3], and an 0.025-inch guidewire was deployed [Figure 4]. The novel plastic stent delivery insertion system was then applied without tract dilation, and the stent was successfully inserted. Although the angle of the posterior bile duct was acute, an appropriate shape of the plastic stent was observed after stent deployment [Figure 5, Video 1]. The stent has not occluded during the 8 months after insertion.
Figure 2.

The posterior bile duct is punctured using a 19-gauge needle.
Figure 3.

Cholangiography shows the dilated posterior bile duct.
Figure 4.

A 0.025-inch guidewire is deployed.
Figure 5.

Although the angle of the posterior bile duct is acute, an appropriate shape of the plastic stent is observed after stent deployment.
Video Still. EUS-guided hepaticoduodenostomy using a novel plastic stent for isolated posterior bile duct obstruction.
Videos are available only at the official website of the journal (http://www.eusjournal.com).
In conclusion, the REGULUS plastic stent may be useful during EUS-HDS, as well as for endoscopic retrograde cholangiopancreatography.
Footnotes
Published online: 14 December 2023
Contributor Information
Saori Ueno, Email: onchannopasocon@yahoo.cop.jp.
Jun Sakamoto, Email: sakamoto.jun0917@gmail.com.
Nobuhiro Hattori, Email: nobuhero.222@gmail.com.
Hiroki Nishikawa, Email: nishikawa_6392_0207@yahoo.co.jp.
Informed Consent Statement
The authors certify that they have obtained all appropriate patient consent forms. In the form, the patient has given his consent for his images and other clinical information to be reported in the journal. The patient understands that his name and initials will not be published and due efforts will be made to conceal his identity, but anonymity cannot be guaranteed.
Conflict of Interest
Takeshi Ogura is an Editorial Board Member of the journal. This article was subject to the journal's standard procedures, with peer review handled independently of the editor and his research group. The authors declare that they have no financial conflict of interest with regard to the content of this report.
Author Contributions
Saori Ueno, Takeshi Ogura wrote a paper. Saori Ueno, Takeshi Ogura, Jun Sakamoto, Nobuhiro Hattori, and Hiroki Nishikawa revised the work critically for important intellectual content, gave final approval of the version to be published, and agree to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.
References
- 1.Park SJ Choi JH Park DH, et al. Expanding indication: EUS-guided hepaticoduodenostomy for isolated right intrahepatic duct obstruction (with video). Gastrointest Endosc 2013;78:374–780. [DOI] [PubMed] [Google Scholar]
- 2.Ogura T Sano T Onda S, et al. Endoscopic ultrasound–guided biliary drainage for right hepatic bile duct obstruction: novel technical tips. Endoscopy 2015;47:72–75. [DOI] [PubMed] [Google Scholar]
- 3.Ma KW So H Cho DH, et al. Durability and outcome of endoscopic ultrasound–guided hepaticoduodenostomy using a fully covered metal stent for segregated right intrahepatic duct dilatation. J Gastroenterol Hepatol 2020;35:1753–1760. [DOI] [PubMed] [Google Scholar]