As a newly qualified preregistration house officer, alone on an orthopaedic ward one weekend, I was asked to review a patient complaining of pleuritic chest pain. This meant considering a short list of differential diagnoses to treat or exclude. Among these, of course, was pulmonary embolism, hence a d-dimer test seemed relevant. I can't remember much about this specific encounter, but I know I thought, worried, and procrastinated for as long as it took for the blood results to come back. Then I bleeped the medical registrar to ask what to do about the abnormal d-dimer test result.
The most memorable part of the encounter was when I handed over the case to the orthopaedic senior house officer the next day. He quoted a paper from Thorax from the year before about the usefulness of d-dimer measurement for excluding pulmonary embolism.1 He seemed to think that my evaluation of the patient would have been much better if I had known the results of this paper. I was impressed and read the paper, which reported a one year prospective observational study of exclusion of pulmonary embolus without the need for lung scans.
Thus armed with a few rules for excluding pulmonary embolus, I worked for six months in the accident and emergency department in the same hospital. I think it went well. I had learnt from this paper that the d-dimer concentration (even measured by a commercial assay based on the agglutination of red blood cells) was useful in excluding pulmonary embolus. I had also learnt the importance of the arterial oxygen tension on air and the respiratory rate in the exclusion of pulmonary embolus. According to the paper, the predictive value of a negative d-dimer test result for excluding a pulmonary embolus was 0.99. Likewise the predictive value was 0.97 for an arterial oxygen tension of >10.7 KPa on air and 0.95 if the respiratory rate was <21 breaths per minute. The sensitivity of d-dimer concentration alone in detecting pulmonary embolus was 95%. The authors felt that if two or more of these parameters were normal, pulmonary embolus was most unlikely and a lung scan was not usually necessary.
I carried over my enthusiasm for d-dimer testing to another hospital in which I was a medical senior house officer. Here I was proud that my new consultant soon began referring to it as Clark's test—but only for as long as it took me to realise that “Clark's test” was synonymous with “yet another positive d-dimer test to be ignored.” I went back to the paper. This time I came away remembering that the specificity of a positive d-dimer test result for pulmonary embolus was only 54%. Trauma, infection, and inflammation were also potential causes of a positive d-dimer.
I continue to request d-dimer measurements, but fewer than I used to. Although the test is good at excluding thromboembolic disease when this must be excluded, it adds little to the assessment of most patients with other obvious cardiorespiratory disease and no specific reason to exclude a pulmonary embolus. Furthermore, overenthusiastic requesting at best invites the sarcasm of those who know better and at worst causes overinvestigation of your patients.
References
- 1.Egermayer P, Town GI, Turner JG, Heaton DC, Mee AL, Beard MEJ. Usefulness of d-dimer, blood gas, and respiratory rate measurements for excluding pulmonary embolism. Thorax. 1998;53:830–834. doi: 10.1136/thx.53.10.830. [DOI] [PMC free article] [PubMed] [Google Scholar]