Abstract
Background
Administrative health data and cardiac device registries can be used to empirically evaluate outcomes and costs after implantable cardioverter defibrillator (ICD) implantation. These datasets often have incomplete information on the indication for implantation (primary vs secondary prevention of sudden cardiac death).
Methods
We used 16 years of population-based cardiac device registry and administrative health data from British Columbia, Canada, to derive and internally validate statistical models that predict the likely indication for ICD implantation. We used chart review data as the reference standard for ICD indication in the Cardiac Device Registry database (CDR; 2004-2012 [Cardiac Services BC]) and nonmissing indication as the reference standard in the Heart Information System registry database (HEARTis; 2013-2019 [Cardiac Services BC]). We created 3 logistic regression prediction models in each database: one using only registry data, one using only administrative data, and one using both registry and administrative data. We assessed the predictive performance of each model using standard metrics after optimism correction with 200 bootstrap resamples.
Results
Models that used registry data alone demonstrated excellent predictive performance (sensitivity ≥ 89%; specificity ≥ 87%). Models that used only administrative data performed well (sensitivity ≥ 84%; specificity ≥ 70%). Models that used both registry and administrative data showed modest gains over those that used registry data alone (sensitivity ≥ 90%; specificity ≥ 89%).
Conclusions
Administrative health data and cardiac device registry data can distinguish secondary prevention ICDs from primary prevention ICDs with acceptable sensitivity and specificity. Imputation of missing ICD indication might make these data resources more useful for research and health system monitoring.
Résumé
Contexte
Les données administratives de santé et les registres des dispositifs cardiaques peuvent être utilisés pour évaluer de manière empirique les résultats et les coûts associés aux défibrillateurs cardioverteurs implantables (DCI). Or, ces ensembles de données comportent souvent des informations incomplètes sur l’indication de l’implant (prévention primaire ou secondaire de la mort subite d’origine cardiaque).
Méthodologie
Nous avons analysé 16 ans de données provenant du registre populationnel des dispositifs cardiaques et des données administratives de santé de la Colombie-Britannique, au Canada, pour alimenter des modèles statistiques prédisant l’indication probable de l’implant d’un DCI et pour effectuer une validation interne de ces modèles. Nous avons utilisé les données de la revue des dossiers médicaux comme norme de référence de l’indication des DCI dans le registre des dispositifs cardiaques (Cardiac Device Registry; 2004-2012 [Cardiac Services BC]) et les indications consignées comme norme de référence dans la banque de données Heart Information System (HEARTis; 2013-2019 [Cardiac Services BC]). Nous avons créé 3 modèles prédictifs par régression logistique dans chaque base de données : une utilisant seulement les données du registre, une utilisant seulement les données administratives et une utilisant les deux types de données. Nous avons évalué la performance de chaque modèle en matière de prédiction à l’aide de mesures normalisées, après correction pour l’optimisme de l’erreur à l’aide de 200 nouveaux échantillons obtenus par la méthode bootstrap.
Résultats
Les modèles utilisant seulement les données du registre avaient une excellente performance prédictive (sensibilité ≥ 89 %; spécificité ≥ 87 %). Les modèles qui n’utilisaient que les données administratives donnaient quant à eux de bons résultats (sensibilité ≥ 84 %; spécificité ≥ 70 %). Enfin, les modèles qui utilisaient les données administratives et les données du registre ont donné des gains modestes par rapport aux modèles qui n’utilisaient que les données du registre (sensibilité ≥ 90 %; spécificité ≥ 89 %).
Conclusions
Les données administratives de santé et les données des registres de dispositifs cardiaques permettent de distinguer les DCI implantés en prévention secondaire des DCI implantés en prévention primaire avec une sensibilité et une spécificité acceptables. Dans les cas où elle est absente, l’attribution d’une indication pour les DCI pourrait donc rendre ces ressources plus utiles pour la recherche et la surveillance du système de santé.
Every year, over 150,000 patients in the US and 7000 patients in Canada receive an implantable cardioverter defibrillator (ICD) for the prevention of sudden cardiac death (SCD).1,2 Despite the life-saving benefits of ICDs, up to 9% of patients experience a complication in the first 16 months after implantation,3 and approximately 1 in 4 transvenous ICD leads have a mechanical complication within 10 years.4 ICDs also are expensive, with previous estimates suggesting a cost of up to US∖$70,200 per quality-adjusted life-year gained.5
Two main sources of routinely collected health data could improve our understanding of the real-world benefits, risks, and cost-effectiveness of ICDs.6 Cardiac device registries include granular clinical information from the time of implantation but usually lack data on external costs and long-term outcomes.7 Administrative health data are collected for billing and healthcare insurance purposes and typically lack granular clinical information. However, they often include data on most medical services used by a large population over a long period of time, making it possible to select control subjects, estimate overall healthcare system costs, and evaluate longer-term outcomes (an important feature when studying preventative treatments such as ICDs).6 Compared to randomized controlled trials, retrospective studies using routinely collected health data can be faster, cheaper, easier to perform, and potentially less prone to commercial conflicts of interest.6,8 These advantages are valuable because assessments of effectiveness need to be revised periodically as ICD technology improves (eg, new device programming can affect shock incidence; different models of transvenous leads can affect complication rates).4,9 These features also make routinely collected health data useful for health system surveillance, including assessment of uptake and evaluation of disparities in access to ICDs.10,11
Establishing the indication for ICD implantation in routinely collected health data is particularly important to allow reassessment of the benefits and risks of primary prevention ICDs.8 Heart failure patients who would be candidates to receive primary prevention ICDs have seen a decline in SCD risk in recent decades because of improved medical therapy and larger competing risks for mortality in an older and more comorbid population.8,12,13 Evidence from older landmark randomized control trials may therefore no longer reflect current clinical reality. Unfortunately, the indication for ICD implantation is missing from routinely collected health data in many countries.6,10,11,14, 15, 16 Indication for ICD implantation can be missing from cardiac device registries because data entry into the registry may not be compulsory, physician documentation may be incomplete, and funding for data collection may be inconsistent.14,16, 17, 18 Indication can be missing from administrative health data because these details are often irrelevant for billing purposes.6 These data gaps are a major barrier to research and health system surveillance.
Accordingly, we used 16 years of population-based administrative health and cardiac device registry data to derive and internally validate statistical models to predict the indication for ICD implantation.
Methods
Setting
Our study was set in British Columbia (BC), Canada. BC's 5.4 million residents are universally insured for medically necessary health services including ICD implantation.19 ICD implantations are performed at only 5 specialized hospitals in the province.
Registry data
We obtained population-based cardiac device registry data from Cardiac Services BC (CSBC). CSBC cardiac device registries include data on all cardiac devices implanted throughout the province. Between 1995 and 2013, CSBC collected these data in their Cardiac Device Registry (CDR). The CDR originally did not capture the indication for ICD implantation, but Hawkins et al. later performed a retrospective clinical record review study to establish indication for ICD implantations occurring between January 2003 and March 2012.14 We used data from this chart review as the reference standard for ICD indication in the CDR (although only data from 2004 to 2012 were available to us). Starting on October 11, 2013, CSBC switched to a new data collection form and a new registry database (the Heart Information System [HEARTis]). HEARTis has a specific field where ICD indication can be specified, but entries for this field are sometimes missing. We used recorded (nonmissing) indication as the reference standard in HEARTis. The current study used registry data from these sources for ICDs implanted between January 1, 2004 and October 31, 2019.
Administrative data
We used unique provincial Personal Health Numbers (PHNs) to deterministically link cardiac device registry data to population-based, individual-level administrative health data that includes information on hospitalizations, physician fee-for-service claims, and all outpatient prescription medications filled at any community pharmacy in BC (Supplemental Table S1).20 We identified ICD implantations in the administrative data by finding the hospital episode-of-care record that corresponded to the implantation date from the cardiac device registry and included a Canadian Classification of Health Intervention code denoting ICD implantation (ie, 1HZ53GRFS, 1HZ53GRFU, 1HZ53HNFS, 1HZ53LAFS, 1HZ53LAFU, 1HZ53SYFS, 1HZ53SYFU, 1HZ53HAFS).
We deemed comorbidities to be present in the administrative data when, over a 1-year look-back interval, relevant diagnostic codes were found in any of the 25 diagnosis fields for ≥ 1 hospitalizations or in any of the 5 diagnosis fields for ≥ 2 physician visits, using diagnostic codes from the International Statistical Classification of Diseases and Related Health Problems, 10th revision, Canadian version (ICD-10-CA in the Discharge Abstract Database and International Classification of Diseases, 9th revision—Clinical Modification [ICD-9-CM] in the Medical Services Plan data). We identified active prescription medication use based on the dispensation date and days supplied for all prescriptions.
Cohort, predictors, and analysis
Our study cohort included an individual's first ICD implantation if it met the following criteria: (i) occurred between January 1, 2004 and October 31, 2019; (ii) could be identified in both the cardiac device registry and the administrative health data; (iii) had an indication for implantation recorded in the corresponding reference standard; and (iv) had a device type recorded in the cardiac device registry data (ie, single-chamber, dual-chamber, cardiac resynchronization therapy). We identified potential predictors of ICD indication based on clinical plausibility (Supplemental Tables S2 and S3).
We fit several logistic regression models that used variables from the cardiac device registry and from the administrative health data to predict whether an ICD was implanted for secondary prevention of SCD. We fit separate models in the CDR (2004-2012) and in HEARTis (2013-2019) because each database collected different variables. When a particular clinical feature was captured by both administrative and registry data and we were fitting a model using both data sources, we deemed the comorbidity or medication to be present if it was identified as present in either database. We did not perform any variable selection, because our goal was to predict indication instead of establishing causality. We compared the predicted ICD indication to the ICD indication established using the reference standard and assessed the sensitivity, specificity, positive predictive value, negative predictive value, and C-statistic (area under the receiver operating curve) of the predictive algorithm after optimism correction with 200 bootstrap resamples.21
Ethics
The University of BC Clinical Research Ethics Board approved the study and waived the requirement for individual consent (H16-02043). Analysis occurred between January 2022 and September 2023, using R, version 4.0 (R Foundation, Vienna, Austria). All inferences, opinions, and conclusions drawn are those of the authors and do not reflect the opinions or policies of the Data Stewards. Research reporting adheres to the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) guidelines.
Results
The final study cohort consisted of 5936 first ICD implantations (Fig. 1). The number of ICDs implanted annually increased more than 3-fold over the 16-year study interval (Fig. 2). In total, 1341 of the 3008 ICDs included from the CDR (45%), and 1436 of the 2928 ICDs included from HEARTis (49%), were implanted for secondary prevention of SCD.
The final study cohort was predominantly male and had a median age of 66 years (Table 1). Baseline comorbidities and active medications were typical of individuals undergoing ICD implantation, with a majority having a history of ischemic heart disease, heart failure, and cardiac arrhythmia, and a majority having been prescribed beta-blockers and angiotensin-converting enzyme (ACE) inhibitors.
Table 1.
Characteristic | Entire CDR (1995–2012), n = 5575 | CDR included in final cohort∗, n = 3008 (54%) | Entire HEARTis (2013–2019), n = 3844 | HEARTis included in final cohort∗, n = 2928 (76%) |
---|---|---|---|---|
Demographics | ||||
Median age, y [Q1, Q3] | 65 [55.5, 72] | 65.5 [57, 73] | 67 [58, 74] | 67 (58, 74) |
Male sex | 4575 (82.1) | 2465 (81.9) | 3026 (78.7) | 2324 (79.4) |
Neighbourhood income quintile | ||||
First (lowest income) | 1056 (18.9) | 561 (18.7) | 757 (19.7) | 586 (20) |
Second | 1151 (20.6) | 643 (21.4) | 723 (18.8) | 558 (19.1) |
Third | 1100 (19.7) | 618 (20.5) | 776 (20.2) | 605 (20.7) |
Fourth | 1044 (18.7) | 566 (18.8) | 766 (19.9) | 598 (20.4) |
Fifth (highest income) | 1080 (19.4) | 574 (19.1) | 710 (18.5) | 547 (18.7) |
Missing | 144 (2.6) | 46 (1.5) | 112 (2.9) | 34 (1.2) |
Medical history in prior year | ||||
CCI ≥ 2 | 2870 (51.5) | 1646 (54.7) | 2150 (55.9) | 1668 (57) |
≥ 1 hospitalization | 5514 (98.9) | 3008 (100) | 3776 (98.2) | 2928 (100.0) |
≥ 7 physician visits | 5420 (97.2) | 2974 (98.9) | 3717 (96.7) | 2885 (98.5) |
Any heart condition | 5453 (97.8) | 2975 (98.9) | 3712 (96.6) | 2885 (98.5) |
Myocardial infarction | 1529 (27.4) | 784 (26.1) | 958 (24.9) | 741 (25.3) |
Congestive heart failure | 4079 (73.2) | 2402 (79.9) | 2769 (72.0) | 2161 (73.8) |
Peripheral vascular disease | 437 (7.8) | 225 (7.5) | 179 (4.7) | 134 (4.6) |
Cerebrovascular disease | 278 (5.0) | 151 (5.0) | 192 (5.0) | 139 (4.7) |
Dementia | 31 (0.6) | 23 (0.8) | 37 (1.0) | 26 (0.9) |
Chronic obstructive pulmonary disease | 621 (11.1) | 345 (11.5) | 428 (11.1) | 334 (11.4) |
Rheumatic disease | 57 (1.0) | 30 (1.0) | 30 (0.8) | 25 (0.9) |
Peptic ulcer disease | 59 (1.1) | 33 (1.1) | 39 (1.0) | 29 (1.0) |
Mild liver disease | 48 (0.9) | 26 (0.9) | 58 (1.5) | 44 (1.5) |
Diabetes | 1407 (25.2) | 852 (28.3) | 1229 (32.0) | 947 (32.3) |
Paraplegia and hemiplegia | 33 (0.6) | 17 (0.6) | 16 (0.4) | 9 (0.3) |
Renal disease | 479 (8.6) | 280 (9.3) | 591 (15.4) | 456 (15.6) |
Cancer | 181 (3.2) | 95 (3.2) | 151 (3.9) | 119 (4.1) |
Moderate or severe liver disease | 8 (0.1) | 0 (0) | 11 (0.3) | 8 (0.3) |
Metastatic carcinoma | 16 (0.3) | ≤ 5 | 12 (0.3) | 7 (0.2) |
HIV | 9 (0.2) | ≤ 5 | 12 (0.3) | 11 (0.4) |
Syncope | 537 (9.6) | 279 (9.3) | 401 (10.4) | 312 (10.7) |
Atrial fibrillation and flutter | 1367 (24.5) | 736 (24.5) | 1027 (26.7) | 804 (27.5) |
Other arrhythmias | 4674 (83.8) | 2461 (81.8) | 2981 (77.5) | 2,313 (79) |
Seizure disorders | 48 (0.9) | 22 (0.7) | 44 (1.1) | 34 (1.2) |
Obstructive sleep apnea and other sleep disorders | 142 (2.5) | 81 (2.7) | 126 (3.3) | 99 (3.4) |
Psychiatric disorders | 734 (13.2) | 410 (13.6) | 601 (15.6) | 466 (15.9) |
Alcohol misuse | 161 (2.9) | 87 (2.9) | 113 (2.9) | 82 (2.8) |
Other substance misuse | 121 (2.2) | 51 (1.7) | 79 (2.1) | 62 (2.1) |
Chronic ischemic heart disease | 3492 (62.6) | 1926 (64.0) | 2252 (58.6) | 1769 (60.4) |
Hypertension | 2404 (43.1) | 1356 (45.1) | 1759 (45.8) | 1366 (46.7) |
Unstable angina | 228 (4.1) | 123 (4.1) | 55 (1.4) | 42 (1.4) |
Pacemaker | ≤ 5 | 0 (0) | 59 (1.5) | 37 (1.3) |
Cardiac arrest | 1036 (18.6) | 523 (17.4) | 898 (23.4) | 714 (24.4) |
Ventricular tachycardia or fibrillation | 3778 (67.8) | 1886 (62.7) | 1849 (48.1) | 1456 (49.7) |
Medications active at baseline | ||||
Number of medications | ||||
0 or 1 | 1428 (25.6) | 653 (21.7) | 1004 (26.1) | 744 (25.4) |
≥ 2 | 4147 (74.4) | 2355 (78.3) | 2840 (73.9) | 2184 (74.6) |
Loop diuretics | 1859 (33.3) | 1094 (36.4) | 1058 (27.5) | 821 (28.0) |
ACEi or ARB | 3193 (57.3) | 1867 (62.1) | 2119 (55.1) | 1631 (55.7) |
MRA | 1287 (23.1) | 788 (26.2) | 1033 (26.9) | 830 (28.3) |
Beta-blockers | 3166 (56.8) | 1852 (61.6) | 2180 (56.7) | 1688 (57.7) |
Nitroglycerin | 558 (10.0) | 306 (10.2) | 234 (6.1) | 180 (6.1) |
Hydralazine | 83 (1.5) | 50 (1.7) | 63 (1.6) | 46 (1.6) |
Antihypertensives | 4172 (74.8) | 2363 (78.6) | 2751 (71.6) | 2116 (72.3) |
Digoxin | 883 (15.8) | 489 (16.3) | 190 (4.9) | 143 (4.9) |
Calcium-channel blockers | 511 (9.2) | 276 (9.2) | 326 (8.5) | 229 (7.8) |
Anti-arrhythmics | 537 (9.6) | 256 (8.5) | 155 (4.0) | 123 (4.2) |
Statins | 2395 (43.0) | 1448 (48.1) | 1790 (46.6) | 1376 (47.0) |
Antiplatelets | 769 (13.8) | 461 (15.3) | 685 (17.8) | 542 (18.5) |
Anticoagulants | 1153 (20.7) | 660 (21.9) | 863 (22.5) | 650 (22.2) |
Insulin | 241 (4.3) | 143 (4.8) | 201 (5.2) | 150 (5.1) |
Oral hypoglycemics | 743 (13.3) | 463 (15.4) | 667 (17.4) | 504 (17.2) |
Opioids | 319 (5.7) | 191 (6.3) | 254 (6.6) | 201 (6.9) |
Benzodiazepines | 643 (11.5) | 357 (11.9) | 307 (8.0) | 243 (8.3) |
Baseline characteristics for the study cohort from both cardiac device registries and administrative health data. Values are n (%), unless otherwise indicated.
ACEi, angiotensin-converting enzyme inhibitor; ARB, angiotensin receptor blocker; CCI, Charlson Comorbidity Index; CDR, Cardiac Device Registry [Cardiac Services BC]; HEARTis, Heart Information System [Cardiac Services BC]; HIV, human immunodeficiency virus; MRA, mineralocorticoid receptor antagonist; Q, quartile.
See text for inclusion criteria. Myocardial infarction, other substance misuse, chronic ischemic heart disease, hypertension, unstable angina, and pacemaker were considered present if ≥ 1 entries were present in the Discharge Abstract Database (DAD) data or ≥ 2 entries were present in the Medical Services Plan (MSP) data.
Predictive models that used both registry and administrative data exhibited excellent ability to predict which ICDs were implanted for secondary prevention (sensitivity ≥ 90%, specificity ≥ 89%, positive predictive value ≥ 91%, and negative predictive value ≥ 87%, in both the CDR and HEARTis; Table 2). Predictive models that used registry data alone also exhibited excellent performance (sensitivity ≥ 89%, specificity ≥ 87%, positive predictive value ≥ 87%, and negative predictive value ≥ 86% in both the CDR and HEARTis). Predictive models based on administrative data alone exhibited very good performance, particularly for the more recently implanted ICDs in the HEARTis database (sensitivity ≥ 84%, specificity ≥ 70%, positive predictive value ≥ 78%, and negative predictive value 78% in both the CDR and HEARTis).
Table 2.
Measure of predictive model performance (optimism-corrected) | CDR (2004–2012), n = 3008 |
HEARTis (201–2019), n = 2928 |
Entire data set (2004–2019), n = 5936 |
||||
---|---|---|---|---|---|---|---|
Both | Registry only | Admin only | Both | Registry only | Admin only | Basic admin variables only∗ | |
Sensitivity | 0.90 | 0.89 | 0.84 | 0.92 | 0.89 | 0.90 | 0.82 |
Specificity | 0.89 | 0.88 | 0.70 | 0.91 | 0.87 | 0.89 | 0.71 |
Positive predictive value | 0.91 | 0.90 | 0.78 | 0.92 | 0.87 | 0.89 | 0.76 |
Negative predictive value | 0.87 | 0.86 | 0.78 | 0.92 | 0.89 | 0.90 | 0.78 |
C-statistic | 0.97 | 0.96 | 0.86 | 0.97 | 0.95 | 0.96 | 0.85 |
Table displays performance metrics for models using only administrative (admin) health data, only cardiac device registry data, and models combining both. Performance metrics were corrected for optimism (the inflation of model performance metrics when evaluated on the same data they are trained on) with 200 bootstraps on the entire training set. The Cardiac Device Registry (CDR; Cardiac Services BC) and Heart Information System (HEARTis; Cardiac Services BC) subsets included in this study consists of only implantable cardioverter defibrillator cases with nonmissing indication that also have corresponding records in admin data. The C-statistic measures the goodness-of-fit of the logistic regression. Table shows excellent model performance in each subset of data.
This model used only basic administrative variables, including age, sex, features of the index hospital visit for ICD implantation (urgency of admission, length of stay ≥ 3 days), and the presence of cardiac arrest, ventricular arrhythmia, and heart failure on the index implantation hospital visit record.
Using registry data alone for both the CDR and HEARTis, history of any of cardiac arrest, ventricular fibrillation, or Brugada syndrome was an extremely strong predictor of secondary prevention ICD, increasing the likelihood by about 2500-fold in the CDR, and deterministically predicting secondary prevention in HEARTis. Elective (rather than “urgent/emergency”) implantation reduced the likelihood of secondary prevention ICD by about half. Left ventricular ejection fraction and New York Heart Association class were not available from the CDR but were only modest predictors of ICD indication in HEARTis. Other predictors were highly plausible, supporting the face validity of our approach (Supplemental Tables S4 and S5).
Using administrative data alone for both the CDR and HEARTis, the identification of specific comorbidities during the index hospital visit for ICD implantation changed the likelihood of a secondary prevention ICD: A history of cardiac arrest increased the likelihood by almost 10-fold; a history of ventricular arrhythmia more than doubled the likelihood; and a history of heart failure reduced the likelihood by about 60% (Supplemental Table S6). The specific medications that were active at implantation date had a modest influence on the likelihood of secondary prevention ICD.
Based on our findings, we also evaluated a simplified predictive model based on administrative data alone that included only age, sex, features of the index hospital visit for ICD implantation (urgency of admission, length of stay ≥ 3 days), and an index implantation hospital visit record that notes current or prior cardiac arrest, ventricular arrhythmia, or heart failure. Using pooled data from the final study cohort, this simplified predictive model exhibited adequate performance for the prediction of secondary prevention ICDs (Table 2; sensitivity 82%, specificity 71%, positive predictive value 76%, negative predictive value 78%, and C-statistic 0.85).
Discussion
Using 16 years of retrospective population-based data for 5936 ICD implantations, we found that cardiac device registry and administrative health data could be used to predict which ICDs were implanted for secondary prevention of SCD. We found that predictive models based on a combination of registry data and administrative health data demonstrated excellent predictive performance, models based on registry data alone demonstrated excellent predictive performance, and models based on administrative health data alone demonstrated acceptable performance. These findings have potential utility to researchers (who may wish to evaluate ICD uptake, benefits, risks, and cost-effectiveness), to administrators (who may wish to monitor healthcare system performance), and to clinicians (who may wish to compare practice patterns with peers). To help with these tasks, we provide data on the degree to which specific demographic, clinical, and procedural variables predict that an ICD was implanted for secondary prevention of SCD (Supplemental Tables S4-S8). We note that similar variables are frequently available in other cardiac device registries, highlighting the potential generalizability of our work.22, 23, 24, 25
Prior studies would have benefitted from a validated method for establishing the indication for ICD implantation.6,10,11,15,16 A pioneering 2013 Italian study used administrative health data to examine the real-world impacts and costs of ICD treatment, but the analysis was limited by a lack of data on indication.6 Cost-benefit analyses that ignore ICD indication may misinform clinicians on the extent to which the treatment is beneficial. A retrospective cohort of 14,230 patients in the US examined ICD shock recurrence in a remote monitoring registry, relying on recorded reasons for device implantation, such as “ventricular tachycardia” to indicate a secondary prevention ICD, or “congestive heart failure” to indicate a primary prevention ICD.15 However, 61% of the cohort had to be excluded because the markers for inferring primary or secondary prevention were not available. A nationwide assessment of 8460 ICD recipients in Denmark that used administrative data was forced to rely on ‘prior diagnosis of ventricular tachycardia or cardiac arrest’ to infer secondary prevention indication; patients without these prior diagnoses were assumed to have primary prevention ICDs.16 Applying a similar approach to the CDR (ie, assuming all ICDs are implanted for primary prevention of SCD unless the registry indicates a history of ventricular arrhythmia or cardiac arrest) yields a sensitivity of 64% and a specificity of 73% (Supplemental Table S9). In contrast, our complete registry data predictive model exhibits a sensitivity of 89% and a specificity of 88% in the CDR. In the future, our findings might be used to reliably establish indication for implantation for a greater proportion of study participants, thereby improving statistical power, potentially reducing exposure misclassification, and potentially facilitating more accurate assessment of cost-effectiveness.
Examining the benefits and risks of primary prevention ICD implantation under current guidelines is one such opportunity for research.8,26 Modern primary prevention ICD shock incidence is extremely low; only 0.75% of patients are expected to receive an appropriate therapy in response to an arrhythmia within the first 6 months after implantation.9 Half of all ICD patients aged 65 years or older are expected to die or enter hospice care within 5 years of implantation.27 Many patients will thus be exposed to the risks and expense of ICD implantation without ever receiving a therapy or any survival benefit from their ICD.4,5,8,27 Our model presents an opportunity to use routinely collected health data to study these patients.
Our findings also can be used to strengthen the use of routinely collected health data to monitor health system performance. Several European administrative hospital discharge databases have been validated for tracking ICD implantation rates using the European Heart Rhythm Association’s (EHRA) comprehensive device monitoring system, the EHRA White Book, as a reference standard.11 Another recent study examined 585 ICD implantations in Nova Scotia (Canada) and found that administrative data could identify ICD complications and infections with 92% sensitivity and 100% specificity, compared to a reference standard of retrospective chart review.28 Our findings might be of use because neither the European nor the Canadian discharge databases document the indication for ICD implantation. Efforts to evaluate disparities in access to ICD implantation based on sex, race, socioeconomic factors, and insurance status could also be strengthened substantially using imputed data on ICD indication.10 Our findings thus will make administrative health data far more useful for monitoring complications, assessing disparities in access to primary prevention ICDs, evaluating compliance with clinical guidelines, and informing health policy.
Our study has many strengths. We examined a large cohort of ICD patients using population-based data, suggesting our findings can be generalized to other jurisdictions. The 16 year study interval encompasses the publication of current guidelines for ICD implantation and includes modern ICD technological developments such as antitachycardia pacing.9,29 We selected input variables that are routinely available in cardiac device registries and administrative health data so that our predictive model could be applied by researchers and administrators to other datasets. We examined the predictive performance of models based on registry data alone, administrative data alone, and both registry and administrative data, in an effort to make our findings relevant in a variety of contexts. We used 200 bootstraps to correct for optimism in our assessment of model performance. We developed predictive models that exhibited excellent predictive performance, and we identified several highly predictive or deterministically predictive variables that might be useful for future research.11,15 To our knowledge, this model is the first to be validated for predicting ICD indication in cardiac device registry and administrative health databases.
Our study also has limitations. New York Heart Association classification and left ventricle ejection fraction were not documented in the CDR, reducing model performance. As we relied on the Hawkins et al. data14 to validate our prediction models for a subset of CSBC registry patients, individuals for whom the reference standard indicated an “indeterminate indication” were excluded from analysis. Our study relies on the unverifiable assumption that ICD indication was missing at random. Our predictive models may not perform well if applied to datasets that do not include strong predictors of secondary prevention ICD (eg, history of cardiac arrest and ventricular arrhythmias, length of hospital stay, and urgency of implantation), but the information we provide on the predictive strength of these variables will inform efforts to derive or validate models based on the available predictors.
Conclusions
Variables that are commonly available in cardiac device registries and administrative health data can be used to predict ICD indication. The predictive models we developed could be applied to routinely collected health data to study the real-world uptake, benefits, risks, and cost-effectiveness of ICDs.
Acknowledgments
Data Statement
Access to data provided by the Data Stewards is subject to approval, but it can be requested for research projects through the Data Stewards or their designated service providers. All inferences, opinions, and conclusions drawn are those of the authors and do not reflect the opinions or policies of the Data Stewards.
Ethics Statement
The University of British Columbia Clinical Research Ethics Board approved the study and waived the requirement for individual consent (H16-02043). Analysis occurred between January 2022 and September 2023, using R, version 4.0 (R Foundation, Vienna, Austria). All inferences, opinions, and conclusions drawn are those of the authors and do not reflect the opinions or policies of the Data Stewards. Research reporting adheres to the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) guidelines.
Patient Consent
The authors confirm that patient consent is not applicable to this article because this is a retrospective study using routinely collected administrative data that were de-identified before release to investigators.
Funding Sources
This study was supported by the Heart and Stroke Foundation of Canada (grant number: G-19-0026232). J.A.S. was supported by a Mentored Clinician Scientist Award from the Vancouver Coastal Health Research Institute and a Health Professional-Investigator Award from Michael Smith Health Research BC. J.R.B. was supported by Michael Smith Health Research BC and the British Columbia Emergency Medicine Network. Funding organizations were not involved in the design or conduct of the study, in the collection, management, analysis, or interpretation of the data, or in the preparation, review, or approval of this article.
Disclosures
The authors have no conflicts of interest to disclose.
Footnotes
See page 883 for disclosure information.
To access the supplementary material accompanying this article, visit CJC Open at https://www.cjcopen.ca/ and at https://doi.org/10.1016/j.cjco.2024.02.003.
Supplementary Material
References
- 1.Friedman D.J., Parzynski C.S., Varosy P.D., et al. Trends and in-hospital outcomes associated with adoption of the subcutaneous implantable cardioverter defibrillator in the United States. JAMA Cardiol. 2016;1:900–911. doi: 10.1001/jamacardio.2016.2782. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Kelly S.E., Campbell D., Duhn L.J., et al. Remote monitoring of cardiovascular implantable electronic devices in Canada: survey of patients and device health care professionals. CJC Open. 2020;3:391–399. doi: 10.1016/j.cjco.2020.11.010. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Ezzat V.A., Lee V., Ahsan S., et al. A systematic review of ICD complications in randomised controlled trials versus registries: Is our 'real-world' data an underestimation? Open Heart. 2015;2 doi: 10.1136/openhrt-2014-000198. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Koneru J.N., Jones P.W., Hammill E.F., Wold N., Ellenbogen K.A. Risk factors and temporal trends of complications associated with transvenous implantable cardiac defibrillator leads. J Am Heart Assoc. 2018;7 doi: 10.1161/JAHA.117.007691. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Sanders G.D., Hlatky M.A., Owens D.K. Cost-effectiveness of implantable cardioverter-defibrillators. N Engl J Med. 2005;353:1471–1480. doi: 10.1056/NEJMsa051989. [DOI] [PubMed] [Google Scholar]
- 6.Ghislandi S., Torbica A., Boriani G. Assessing the outcomes of implantable cardioverter defibrillator treatment in a real-world setting: results from hospital record data. BMC Health Serv Res. 2013;13:100. doi: 10.1186/1472-6963-13-100. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Hammill S.C., Curtis J. Publicly reporting implantable cardioverter defibrillator outcomes: grading the report card. Circ Arrhythm Electrophysiol. 2008;1:235–237. doi: 10.1161/CIRCEP.108.819300. [DOI] [PubMed] [Google Scholar]
- 8.Merchant F.M., Levy W.C., Kramer D.B. Time to shock the system: moving beyond the current paradigm for primary prevention implantable cardioverter-defibrillator use. J Am Heart Assoc. 2020;9 doi: 10.1161/JAHA.119.015139. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Steinberg C., Cheung C.C., Wan D., et al. Driving restrictions and early arrhythmias in patients receiving a primary-prevention implantable cardioverter-defibrillator (DREAM-ICD) study. Can J Cardiol. 2020;36:1269–1277. doi: 10.1016/j.cjca.2020.05.029. [DOI] [PubMed] [Google Scholar]
- 10.Patel N.J., Edla S., Deshmukh A., et al. Gender, racial, and health insurance differences in the trend of implantable cardioverter-defibrillator (ICD) utilization: a United States experience over the last decade. Clin Cardiol. 2016;39:63–71. doi: 10.1002/clc.22496. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Banks H., Torbica A., Valzania C., et al. Five year trends (2008-2012) in cardiac implantable electrical device utilization in five European nations: a case study in cross-country comparisons using administrative databases. Europace. 2018;20:643–653. doi: 10.1093/europace/eux123. [DOI] [PubMed] [Google Scholar]
- 12.Shen L., Jhund P.S., Petrie M.C., et al. Declining risk of sudden death in heart failure. N Engl J Med. 2017;377:41–51. doi: 10.1056/NEJMoa1609758. [DOI] [PubMed] [Google Scholar]
- 13.Køber L., Thune J.J., Nielsen J.C., et al. Defibrillator implantation in patients with nonischemic systolic heart failure. N Engl J Med. 2016;375:1221–1230. doi: 10.1056/NEJMoa1608029. [DOI] [PubMed] [Google Scholar]
- 14.Hawkins N.M., Grubisic M., Andrade J.G., et al. Long-term complications, reoperations and survival following cardioverter-defibrillator implant. Heart. 2018;104:237–243. doi: 10.1136/heartjnl-2017-311638. [DOI] [PubMed] [Google Scholar]
- 15.Merchant F.M., Hoskins M.H., Benser M.E., et al. Time course of subsequent shocks after initial implantable cardioverter-defibrillator discharge and implications for driving restrictions. JAMA Cardiol. 2016;1:181–188. doi: 10.1001/jamacardio.2015.0386. [DOI] [PubMed] [Google Scholar]
- 16.Schmidt M., Pedersen S.B., Farkas D.K., et al. Thirteen-year nationwide trends in use of implantable cardioverter-defibrillators and subsequent long-term survival. Heart Rhythm. 2015;12:2018–2027. doi: 10.1016/j.hrthm.2015.04.040. [DOI] [PubMed] [Google Scholar]
- 17.Mack C., Su Z., Westreich D. Agency for Healthcare Research and Quality; Rockville, MD: 2018. Managing Missing Patient Data in Patient Registries. White Paper, addendum to Registries for Evaluating Patient Outcomes: A User’s Guide, Third Edition. (Prepared by L&M Policy Research, LLC, under Contract No. 290-2014- 00004-C.) AHRQ Publication No. 17(18)-EHC015-EF.www.effectivehealthcare.ahrq.govhttps://www.ncbi.nlm.nih.gov/books/NBK493611 Available at: [DOI] [PubMed] [Google Scholar]
- 18.Pop B., Fetica B., Blaga M.L., et al. The role of medical registries, potential applications and limitations. Med Pharm Rep. 2019;92:7–14. doi: 10.15386/cjmed-1015. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Sydor M., Kortum M., Carson J., Riddel S., Doyle J. Office of the Auditor General of British Columbia; Victoria (Canada): 2013. Health funding explained; p. 38.https://www.bcauditor.com/sites/default/files/publications/2013/special/report/Health%20Funding%20Explained%20Report.pdf Available at: [Google Scholar]
- 20.Population Data BC. Population Data BC; Vancouver, BC: 2016. www.popdata.bc.ca Available at: [Google Scholar]
- 21.Harrell F.E. Jr, Lee K.L., Mark D.B. Multivariable prognostic models: issues in developing models, evaluating assumptions and adequacy, and measuring and reducing errors. Stat Med. 1996;15:361–387. doi: 10.1002/(SICI)1097-0258(19960229)15:4<361::AID-SIM168>3.0.CO;2-4. [DOI] [PubMed] [Google Scholar]
- 22.Zhang T., Lau K., Ko D. Canadian Cardiovascular Society; Ottawa, Canada: 2010. Evaluation of Canadian, American and international cardiovascular registries; p. 25.https://ccs.ca/wp-content/uploads/2020/12/Evaluation-of-Registries.pdf Available at: [Google Scholar]
- 23.Dodson J.A., Reynolds M.R., Bao H., et al. Developing a risk model for in-hospital adverse events following implantable cardioverter-defibrillator implantation: a report from the NCDR (National Cardiovascular Data Registry) J Am Coll Cardiol. 2014;63:788–796. doi: 10.1016/j.jacc.2013.09.079. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.National Cardiovascular Device Registry . American College of Cardiology Foundation; Washington, DC: 2021. EP Device Implant Registry Coder’s Data Dictionary v2.3; p. 5.https://cvquality.acc.org/NCDR-Home/registries/hospital-registries/ep-device-implant-registry Available at: [Google Scholar]
- 25.Yousuf O.K., Kennedy K., Russo A., et al. Appropriateness of implantable cardioverter-defibrillator device implants in the United States. Heart Rhythm. 2024;21:397–407. doi: 10.1016/j.hrthm.2023.12.005. [DOI] [PubMed] [Google Scholar]
- 26.Ursaru A.M., Petris A.O., Costache I.I., et al. Implantable cardioverter defibrillator in primary and secondary prevention of SCD - What we still don’t know. J Cardiovasc Dev Dis. 2022;9:120. doi: 10.3390/jcdd9040120. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Reeder H.T., Shen C., Buxton A.E., Haneuse S.J., Kramer D.B. Joint shock/death risk prediction model for patients considering implantable cardioverter-defibrillators. Circ Cardiovasc Qual Outcomes. 2019;12 doi: 10.1161/CIRCOUTCOMES.119.005675. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Parkash R., Sapp J., Gardner M., et al. Use of administrative data to monitor cardiac implantable electronic device complications. Can J Cardiol. 2019;35:100–103. doi: 10.1016/j.cjca.2018.10.018. [DOI] [PubMed] [Google Scholar]
- 29.Ammannaya G.K.K. Implantable cardioverter defibrillators—the past, present and future. Arch Med Sci Atheroscler Dis. 2020;5:e163–e170. doi: 10.5114/amsad.2020.97103. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.