Occupational allergy after exposure to caddis flies at a hydroelectric power plant.

A Kraut 1, J Sloan 1, F Silviu-Dan 1, Z Peng 1, D Gagnon 1, R Warrington 1
PMCID: PMC1127997  PMID: 8044233

Abstract

A cross sectional survey was conducted in a hydroelectric power plant in which the workforce was exposed to large numbers of caddis flies. 28 of 57 employees participated. About 50% of the participants reported work related eye, nose, and sinus symptoms and wheezing. Working in locations with greater exposure to caddis flies was significantly associated with work related symptoms. 17 workers (61%) were skin prick positive to a laboratory prepared caddis fly antigen (LCFA) made from the remains of caddis flies present in the plant and 11 (39%) had positive reactions to a commercial caddis fly antigen (CCFA). Workers stationed in heavily exposed areas were 3.7 times as likely to have a positive response to the LCFA (p = 0.009) and 5.3 times as likely to have a positive response to the CCFA (p = 0.036). 13 (46%) of survey respondents reported three or more work related symptoms. 10 (91%) CCFA positive workers reported three or more work related symptoms. Pulmonary function studies revealed slight, but not significantly decreased forced vital capacity (FVC), forced expiratory volume in one second (FEV1), and FEV1/FVC ratios in workers who were skin test positive to either caddis fly preparation when compared with those who were negative. One worker who was skin test positive to both antigens had a cross shift fall in FEV1 of 20% predicted. Occupational allergy to caddis flies proved to be a significant health problem at this work site.

Full text

PDF

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Ferris B. G. Epidemiology Standardization Project (American Thoracic Society). Am Rev Respir Dis. 1978 Dec;118(6 Pt 2):1–120. [PubMed] [Google Scholar]
  2. Kino T., Chihara J., Fukuda K., Sasaki Y., Shogaki Y., Oshima S. Allergy to insects in Japan. III. High frequency of IgE antibody responses to insects (moth, butterfly, caddis fly, and chironomid) in patients with bronchial asthma and immunochemical quantitation of the insect-related airborne particles smaller than 10 microns in diameter. J Allergy Clin Immunol. 1987 Jun;79(6):857–866. doi: 10.1016/0091-6749(87)90233-8. [DOI] [PubMed] [Google Scholar]
  3. Morris J. F., Koski A., Johnson L. C. Spirometric standards for healthy nonsmoking adults. Am Rev Respir Dis. 1971 Jan;103(1):57–67. doi: 10.1164/arrd.1971.103.1.57. [DOI] [PubMed] [Google Scholar]
  4. Peng Z., Simons F. E., Becker A. B. Measurement of ragweed-specific IgE in canine serum by use of enzyme-linked immunosorbent assays, containing polyclonal and monoclonal antibodies. Am J Vet Res. 1993 Feb;54(2):239–243. [PubMed] [Google Scholar]