ABSTRACT
Introduction
Whole-body plethysmography is the preferred method for measuring the static lung volumes: total lung capacity (TLC), functional residual capacity (FRC) and residual volume (RV), as it also incorporates trapped gas – a common finding in chronic obstructive pulmonary disease (COPD). Quantitative computed tomography (CT) is a promising alternative to plethysmography, which can be challenging to perform for patients with severely impaired lung function. The present systematic review explores the agreement between lung volumes measured by plethysmography and CT, as well as the attempts being made to optimize alignment between these two methods.
Methods
A literature search was performed on the PubMed database using the block search strategy. Articles were included if they provided both CT based and plethysmography based TLC. Risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) checklist.
Results
22 articles were included. On average, CT-derived TLC (CT-TLC) was 709 mL lower compared to plethysmography TLC (p-TLC) with a 12.1% deviation from the reference standard, p-TLC. This discrepancy (ΔTLC) appeared slightly larger in obstructive patients (obstructive: 781 mL, non-obstructive: 609 mL), whereas percent deviation was slightly smaller (obstructive: 11.4%, non-obstructive: 13.5%). CT-based RV analyses primarily based on COPD patients measured 603 mL higher than plethysmography (p-RV) with 17.8% deviation from p-RV. Studies utilizing spirometry-gating for CT acquisition reported good agreement between modalities (ΔTLC: 70–280 mL), and one study demonstrated noticeable improvements compared to conventional breath-hold instructions in an otherwise identical study setting.
Conclusion
CT quantifications routinely underestimate TLC and overestimate RV in comparison to plethysmography. Spirometry gating reduces the level of disagreement and can be of assistance when patients are already undergoing CT. However, further studies are needed to confirm these results.
KEYWORDS: Systematic review, total lung capacity, functional residual capacity, residual volume, static lung volumes, computed tomography, body box, whole-body plethysmography
Introduction
After its introduction in 1956 [1], whole-body plethysmography has been regarded as gold standard for measuring static lung volumes including residual volume (RV), functional residual capacity (FRC) and total lung capacity (TLC). Methods based upon multiple-breath gas dilution or washout techniques depend on communicating gas and thus only measure a subject’s ventilated lung volumes. In contrast, plethysmography includes also trapped air so it is applicable for patients with lung diseases characterized by air trapping such as chronic obstructive pulmonary disease (COPD) [2]. Performing the necessary respiratory maneuvers correctly requires meticulous coaching and multiple attempts [3]. This can be especially demanding for patients with severely impaired lung function and might not be suitable for patients (e.g. children) who find it challenging to follow instruction. In addition, the intermittent closure of air flow and compact dimensions of the body box can induce panic attacks in patients suffering from claustrophobia.
CT lung volumetrics is promising as an alternative tool for assessing pulmonary function and volumes. Furthermore, software can both quantify degree of emphysema and segment the lung into pulmonary lobes, which is helpful when selecting lobes as target for lung volume reduction therapy.
A technician or voice recording usually instructs the patient to fully inhale or exhale and hold still as the CT scan is performed. Patient cooperation and scan timing is among the challenges faced and can be managed by spirometry-gating and other solutions.
The aim of this systematic review is to assess the agreement between static lung volumes measured by quantitative CT volumetrics and body plethysmography and explore the attempts being made to optimize alignment. It is hypothesized that inspiratory CT-based volumes underestimate TLC and expiratory CT-based volumes overestimate RV whereas spirometry gating reduces the level of disagreement.
Methods
Search and study selection
The research question was ‘What is the agreement between lung volumes measured with CT and body box?’ A systematic search strategy was applied on PubMed using block-searching strategy with the entries: (TLC OR RV) AND CT AND plethysmography. The first broad search identified 1405 results (Table A1. Search Protocol #1) and a second, narrower search yielded 111 results (Table A2. Search Protocol #2). Titles and abstracts were screened, and articles were assessed for eligibility by screening the full-text version. Reference lists were searched for additional relevant articles. Articles had to include human subjects and TLC derived from CT acquired at maximum inspiration as well as plethysmography TLC as comparator. Results had to be original studies in English or a Scandinavian language and include an abstract and a full-text version.
The selection process is visualized using a Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) flow diagram (Figure 1) [4].
Figure 1.

PRISMA flow diagram.
Since whole-body plethysmography is the gold standard for measuring static lung volumes, articles based on multiple-breath gas dilution or washout methods were excluded. If studies provided data from before and after thoracic surgery, only pre-surgery data was included to avoid patients contributing to the result multiple times.
Risk of bias
The Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool was used for evaluating the risk of bias and method quality (Figure 2) [5]. For each article, the following domains were evaluated: patient selection, index test, reference standard, and flow and timing.
Figure 2.

Risk of bias and applicability assessment using the QUADAS-2 tool.
It was considered appropriate if plethysmography was performed according to guidelines, such as from the American Thoracic Society and European Respiratory Society [3], or if the described method of static spirometry followed the same standards. A maximum time interval of 30 days between pulmonary function testing and CT acquisition was considered appropriate. However, the acceptable interval was shortened if patients had fluctuating lung function impairment such as in asthma.
Results
Search
We identified 115 articles via the database search (Figure 1) comprising 111 from the final search and additionally four from the original search (Tables A1 and 2). Nineteen articles met the inclusion criteria described in Search and Study Selection. An additional three eligible articles were uncovered by screening the reference list of these articles. In total, 22 articles were included for revision; eight studies were prospective and 14 retrospective (Table 1).
Table 2.
Total lung capacity data.
![]() |
Note: Total lung capacity (TLC). ΔTLC: difference between Plethysmograpic-TLC and CT-TLC. In cases where difference was not provided, the authors calculated it as: ΔTLC = P-TLC – CT-TLC. Percent Deviation = (ΔTLC/P-TLC)*100. YACTA, LowATT and Pulmo3D are different CT software packages. Each colour represents a patient group. Blue: mixed. Red: restrictive. Green: healthy. Black: obstructive [1,6–26].
Table 1.
Study characteristics.
| Study | Study Type | Publishing Year | No. of Participants | Age, years (Mean±SD) |
Indication, type of subjects |
|---|---|---|---|---|---|
| Bakker JT et al. | Retrospective, single-center | 2022 | 200 | 62 ± 8 | COPD |
| Barjaktarevic I et al. | Prospective, multi-center | 2015 | 460 | 64 ± 7 | COPD |
| Becker MD et al. | Retrospective, single-center | 1997 | 28 | 65 ± 7 | COPD |
| Brown MS et al. | Retrospective, single-center | 1999 | 43 | – | 21 normal 9 asthma 9 scleroderma 4 COPD |
| Brown MS et al. | Prospective, multi-center | 2010 | 486 | 63 ± 7 | COPD |
| Chen F et al. | Retrospective, single-center | 2011 | 21 | 42 ± 11 | Healthy lung donation candidates |
| Coxson HO et al. | Prospective, multi-center | 2008 | 57 | – | COPD |
| Daghighi A et al. | Retrospective, Multi-center | 2018 | 61 | – | Thoracic scoliosis |
| Garfield JL et al. | Retrospective, single-center | 2012 | 59 | 63 ± 9 | COPD |
| Gawlitza J et al. | Prospective, single-center | 2017 | 46 | 66 ± 10 | COPD |
| Jung WS et al. | Retrospective, single-center | 2016 | 264 | 61 ± 14 | LTx candidates grouped according to PFT results: Normal Obstructive Restrictive |
| Kauczor HU et al. | Prospective, single-center | 1998 | 72 | 59 | Suspected lung disease |
| Lacerda LS et al. | Retrospective, single-center | 2018 | 43 | Cystic fibrosis: 31 Controls: 24 Mean: 27 |
21 Cystic fibrosis 22 Controls |
| Matsumoto AJ et al. | Retrospective, single-center | 2017 | 118 | 54 ± 11 | LTx recipients before transplantation |
| O’Donnell CR et al. | Prospective, multi-center | 2010 | 132 | 60 ± 11 | Various indications for CT |
| Schlesinger AE et al. | Retrospective, single-center | 1994 | 21 | 11 | Follow-up of LTx children |
| Shen M et al. | Prospective, multi-center | 2019 | 29 | 62 | COPD |
| Song L et al. | Retrospective, single-center | 2020 | 172 | 66 ± 7 | COPD |
| Tantucci C et al. | Prospective, single-center | 2016 | 37 | Control:57 ± 11 Obstructive: 70 ± 9 Restrictive: 66 ± 13 |
Subjects grouped according to PFT results: Controls Obstructive Restrictive |
| Wielpütz MO et al. | Retrospective, multi-center | 2014 | 49 | 64 ± 9 | COPD |
| Wu F et al. | Retrospective, single-center | 2021 | 65 | 56 | Healthy |
| Zaporozhan J et al. | Retrospective, multi-center | 2005 | 31 | 60 ± 8 | COPD |
Differences in lung volumes measured by CT and Plethysmography
In the 17 articles that provided absolute TLC volumes derived from plethysmography (p-TLC) and CT (CT-TLC), plethysmography measured a larger volume than quantified in a corresponding inspiratory CT image (Table 2 and Figure 3). On average, p-TLC was 709 mL larger than CT-TLC (maximum: 1380 mL, minimum: 70 mL) and the mean percent deviation was 12.1% (maximum: 23.7%, minimum: 3.7%) with p-TLC as reference.
Figure 3.

Total lung capacity (TLC) plot. plotted values of differences between TLC (in ml) measured with plethysmography and CT (ΔTLC) and given as percent deviation (100% * (plethysmography - CT)/Plethysmography). Black line represents standard deviation when available. Each colour represents a patient group. Blue: mixed. Red: restrictive. Green: healthy. Black: obstructive. [1,7–17,20–24].
All except one study (O’Donnell CR et al. [1]) calculated a correlation coefficient between results from both modalities [1]. In general, CT-TLC correlated well with p-TLC averaging 0.83 (maximum: 0.98, minimum: 0.38). Gawlitza J et al. [6] were the only ones observing a weak association (0.38) between plethysmography- and CT-derived lung volumes.
Seven articles provided absolute measurements of RV [7–13] (Table 3). The mean difference between p-RV and CT-RV was −603 mL (maximum: −1060 mL, minimum: −290 mL), and the average percent deviation was −17.8% (maximum: −39.1%, minimum: −6.0%). Correlations for the RV assessments were somewhat weaker but still good as indicated by an average correlation coefficient of 0.76 (maximum: 0.84, minimum: 0.65).
Table 3.
Residual volume data.
![]() |
Residual volume (RV). ΔRV: difference between Plethysmographic-RV (p-RV) and CT-RV. In cases where difference was not provided, the author calculated it as: ΔRV = P-RV – CT-RV. Percent Deviation = (ΔRV/P-RV)*100. Each colour represents a patient group. Blue: mixed. Green: healthy. Black: obstructive [6–13,25].
Five out of the seven articles on RV studied patients with COPD exclusively [7,8,10,11,13] (Table 3). When comparing pooled volumes in subjects with COPD and non-COPD subjects (these included healthy subjects and patients with suspected lung disease, respectively), it is evident that a moderate disagreement in mean absolute difference between the groups (COPD: −561 mL, non-COPD: −730 mL) contributes to a significant discrepancy in percent deviation from the reference standard, p-RV (COPD: 12.2%, non-COPD: 31.8%) (Figure 4).
Figure 4.

Residual volume (RV) plot. plotted values of differences between RV (in ml) measured with plethysmography and CT (ΔRV) and given as percent deviation (100% * (plethysmography - CT)/Plethysmography). Black line represents standard deviation when available. Each colour represents a patient group. Blue: mixed. Green: healthy. Black: obstructive. [7–13].
When TLC data is divided into an obstructive and a non-obstructive group, ΔTLC appears slightly larger in obstructive patients (obstructive: 781 mL, non-obstructive: 609 mL), whereas percent deviation is slightly smaller (obstructive: 11.4%, non-obstructive: 13.5%) (Figure 3).
Three studies stated that a bronchodilator was administered before performing body plethysmography and CT [7,11,14]. In contrast, Tantucci C et al. stated that when relevant, inhalations were withdrawn 24–48 h beforehand [15]. However, results from these articles did not seem to differ noticeably from other articles on obstructive patients.
Jung WS et al. and Tantucci C et al. categorized subjects into restrictive, obstructive and control groups according to dynamic spirometry results. In the study conducted by Jung WS et al. patients with a restrictive pattern had the smallest ΔTLC, percent deviation and correlation coefficient [16]. In contrast, Tantucci C et al. reported an excellent correlation (0.98, 0.97 and 0.98) and minimal ΔTLC (110 mL, 70 mL and 80 mL) in all patient groups showing no noteworthy variation in the groups [15].
This was also one of only two studies utilizing a spirometer to gate CT acquisition – all other studies gave conventional breath-hold instructions. Bakker JT et al. aimed to investigate the effects of spirometric gating on patients with COPD by comparing it to instructing patients to hold their breath [7]. This technique rendered noticeable improvements in all parameters in an otherwise identical study setting (Tables 2 and 3).
Discussion
The findings of the present review suggest that discrepancy between plethysmography- and CT-derived lung volumes is a universal phenomenon. Specifically, quantitative CT routinely underestimates TLC and overestimates RV in comparison to body plethysmography. Utilizing a spirometer to gate CT acquisition reduces disagreement noticeably though it does not eliminate it entirely.
TLC can be defined as the total gas volume in the lung after a full inspiratory maneuver [3]. It has been challenging to determine whether gas in the conductive airways is included in this definition. Even though it might seem trivial, this appears to be an import factor to consider. Body plethysmography incorporates volumes in the oropharynx, trachea, and anatomic dead space in the main conducting airways [10]. Some types of CT segmentation software include gas volumes in the tracheobronchial tree, others do not. For instance, the post-processing software used in Shen M et al.’s study excluded these volumes [10]. In contrast, Tantucci C et al. included anatomic dead space of 150 mL in their CT-TLC calculations [15]. Compressed gas in the upper gastrointestinal tract might also further increase FRC, which forms the basis for TLC and RV calculations [3].
Another important factor to note is the difference in posture (supine in CT vs. upright position in body plethysmography). By comparing conventional supine CT with upright CT in a specialized CT scanner, a study demonstrated that CT-based inspiratory and expiratory volumes were significantly smaller in the supine position than in the standing and sitting position in healthy subjects [27]. This is largely due to abdominal content pressing up against the diaphragm in the supine position, which has been shown by other studies to reduce vital capacity by less than 10% in normal subjects [17]. This is consistent with the results from the present review showing that CT-TLC is smaller than p-TLC.
However, the above studies contradict the present findings of a generally negative ΔRV (Table 3). This may be due to various CT software packages include lung tissue and blood vessels in their TLC volumetrics, which proportionally makes up more of the total lung volume at full expiration. ΔRV was largely based on data from COPD patients, a disease characterized by hyperinflation and an impaired ability to fully expire. Perhaps, the supine position exacerbates an already present muscle weakness, such as in the accessory expiratory muscles.
Tantucci C et al. calibrated CT and plethysmography TLC results by adding or subtracting the difference between vital capacity obtained in the seated and supine position, respectively, and presented excellent correlations [15] (Table 2).
Body plethysmography measures pressure changes at the mouth opening based on the assumption that these reflect pressure changes in the alveoli during shutter valve occlusion. In the presence of airway obstruction, however, this assumption might fail. O’Donnell CR et al. find that a worsening in airway obstruction leads to increasing overestimation of TLC, which might be due to an incomplete transmission of alveolar pressure changes to the mouth [28]. This may be part of the reason for ΔTLC being slightly larger in studies with data from obstructive patients.
Plethysmography is a very standardized method of determining lung volumes with universally applied guidelines by the American Thoracic Society and the European Respiratory Society [3]. A skilled technician instructs the patient to perform a sequence of respiratory maneuvers, and multiple attempts are made to obtain repeatability of the volume results to correct for variability in patient effort and cooperation, which can be monitored simultaneously.
Due to radiation concerns, CT acquisition is rarely repeated, and thus such unpredictable errors cannot be rectified. This becomes increasingly relevant in patients having difficulty maintaining inspiratory and expiratory breath-hold during the scan due to dyspnea. It is not possible to confirm with certainty the amount of effort patients put into following instructions. As CT accuracy depends on subject performance, being able to monitor patient effort becomes crucial in determining reliability of volume quantifications as well as certain qualitative radiological descriptions.
Bakker JT et al. showed that utilizing a spirometer can help bring CT-based volumes to a closer alignment with plethysmography measurements in patients with severe emphysema [7].
Spirometry gating is an easily applicable tool and largely tolerant to subject’s cooperation. Although studies on this are limited, the technique shows great promise in minimizing disagreements ascribable to patient effort or cooperation between patient and instructor. This would be relevant for patients already undergoing inspiratory and expiratory CT evaluation, such as candidates for lung volume reduction surgery or lung transplantation. For patients without a CT appointment, these improvements do not justify body plethysmography being replaced by spirometry-gated CT as radiation is still a concern.
Spirometers with a shutter valve are also available ensuring total control of airflow. However, Kauczor HU et al. had to discontinue spirometry gating with shutter occlusion as four out of five subjects took the device out of their mouth for both inspiratory and expiratory CT acquisition [9]. Sudden blockage of airflow may not be tolerated by all patients, in particular children, patients suffering from claustrophobia, and patients prone to anxiety, which many people with COPD experience [29].
CT machines differ in scan time ranging from one to several seconds. Many patients with severe lung disease are not capable of holding their breath for the required amount of time – regardless of spirometry gating. The studies using a spirometer scanned their patients within 6 seconds. Thus, their results may not be applicable in hospital departments with slow scanners. Other CT specifications, such as a difference in slice thickness, do not seem to have a significant impact on the results (Table A3).
The limitations of the present review need to be addressed. It was decided to narrow down the literature search, which entails a risk of missing eligible articles. In addition, this review is based on results from one single database, PubMed. It is possible that the results would be different if the search had included more databases e.g. Embase. The good congruence between both modalities may be attributed to the fact that publishers tend to exclude studies if their findings contradict current research in the area.
Another limitation may stem from individual variations in age distribution. Most studies predominantly involved middle-aged patients in their 50s and 60s. However, three studies by Chen F et al. Lacerda LS et al. and Schlesinger AE et al. included younger groups with mean ages of 42, 27 and 11 years, respectively [18–20]. As expected, the first two studies aligned well with overall findings, as they included adult participants whose body composition and size are comparable to those of middle-aged patients.
It might be anticipated that the smaller lung volume of Schlesinger AE et al.’s group, consisting of children with lung transplants aged 3 to 18 years, would result in a smaller absolute difference in total lung capacity, while percentage deviation would likely remain consistent with general outcomes of this study [18]. However, only a correlation coefficient for TLC was provided, which stood at 0.92, indicating a strong correlation as expected.
Based on the QUADAS-2 risk of bias assessment, 16 articles included domains with high risk of bias, whereas two articles demonstrated a low risk of bias. An inappropriately long time interval between plethysmography and CT leads to a high risk rating in the flow and timing domain. Four studies were unclear, as they did not provide sufficient information to assess the domains of interest. The majority of studies were retrospective and they used data originally collected for other purposes. Moreover, there is a risk of extracting patient data out of convenience rather than relevance in this type of study. For instance, Lacerda LS et al. scored a high risk of bias in the patient selection domain due to their study being based on a convenience sample of patients [19]. Yet, there seems to be no difference between retrospective and prospective studies regarding their results.
Conclusion
CT-based volume quantifications align well with lung volumes measured in the whole-body plethysmograph, although a clear tendency to underestimate TLC and overestimate RV in comparison to gold standard plethysmography is evident. Spirometry gating continues to be a suitable tool to reduce disagreement and can be of assistance when patients are already undergoing CT. However, research on this instrument is scarce and limitations of the present review should be considered. Standardization of CT software and further research is needed before evaluation of the static volumes of pulmonary function can be fully based on CT.
. Appendix
Table A1.
Search protocol #.
| Database | Search Strings | Hits |
|---|---|---|
| PubMed 1966 - | #1:(“Lung Volume Measurements”[Mesh]) OR (“Lung volume*” OR “Total lung capacity” OR “TLC” OR “Residual volume” OR “RV” OR “Total lung volume” OR “Functional residual capacity” OR “FRC” OR “Inspiratory lung volume” OR “Expiratory lung volume” OR “Lung-volume quantification” OR “end-inspiratory lung volume” OR “end-expiratory lung volume” OR “Lung volume measurement*” OR “Static lung volumes” OR “Lung Capacity”) | 91782 |
| #2:(“Tomography, X-Ray Computed”[Mesh]) OR (“Computer tomography” OR “computer-assisted tomography” OR “Chest computed tomography” OR “CT” OR “Inspiration CT” OR “Expiration CT” OR “CT-derived lung volumes” OR “Multidetector Computed tomography” OR “computed tomography segmentation” OR “computed tomography” OR “Computerized tomography” OR “Volumetric chest CT” OR “CAT scan” OR “low-dose CT” OR “high-resolution CT” OR “tomodensitometry” OR “quantitative CT”) | 903743 | |
| #3:(“Plethysmography, Whole Body”[Mesh]) OR (“Body plethysmography” OR “plethysmography analysis” OR “plethysmographic” OR “plethysmographic methods” OR “Respiratory function tests” OR “Static spirometry” OR “Body box” OR “Plethysmograph*” OR “Whole Body Plethysmography” OR “Pulmonary function test*”) | 80527 | |
| #1 AND #2 AND #3 | 1405 |
Note: Protocol 1: the original search on PubMed using the block searching strategy.
Table A2.
Search Protocol #2.
| Database | Search Strings | Hits |
|---|---|---|
| PubMed 1966 - | #1: (“Total Lung Capacity”[Mesh]) OR (“Total Lung Capacity” OR “TLC”) | 47199 |
| #2: (“Tomography, X-Ray Computed”[Mesh]) OR (“Computer tomography” OR “computer-assisted tomography” OR “Chest computed tomography” OR “CT” OR “Inspiration CT” OR “Expiration CT” OR “CT-derived lung volumes” OR “Multidetector Computed tomography” OR “computed tomography segmentation” OR “computed tomography” OR “Computerized tomography” OR “Volumetric chest CT” OR “CAT scan” OR “low-dose CT” OR “high-resolution CT” OR “tomodensitometry” OR “quantitative CT”) | 903743 | |
| #3:(“Plethysmography, Whole Body”[Mesh]) OR (“Body plethysmography” OR “plethysmography analysis” OR “plethysmographic” OR “plethysmographic methods” OR “Static spirometry” OR “Body box” OR “Plethysmograph*” OR “Whole Body Plethysmography”) | 25428 | |
| #1 AND #2 AND #3 | 111 |
Note: Protocol 2: the narrowed search on PubMed using the block searching strategy.
Table A3.
CT Specifications.
| Study | Gating | CT Scanner | Slice Thickness (mm) | Scan Time (sec) | Volumetric Software |
|---|---|---|---|---|---|
| Bakker JT et al. | Gated group: Spirometric gating without shutter occlusion. Non-gated group: Breath-hold. |
Second-generation dual source CT scanner (CT Somatom Definition Flash; Siemens, Erlangen, Germany) | 1 | 1.5 | LungQ; Thirona, Nijemegen, The Netherlands |
| Barjaktarevic I et al. | – | Multislice CT scanning (GE Healthcare or Siemens healthcare scanners) | 1, 1.25 | – | Pulmonary Workstation 2.0 software (VIDA Diagnostics Inc) |
| Becker MD et al. | Breath-hold | Conventional scanner (GE 9800 HiLite; GE Medical Systems, Milwaukee, W1) | 10 | – | Custom software written in Visual C++ (Microsoft, Redmond, WA) |
| Brown MS et al. 1999 | Breath-hold | Either helical or electron beam CT. Helical: GE HiSpeed Advantage or CT/I scanners (GE Medical Systems, Milwaukee, WI, U.S.A.). Electron beam: Siemens Evolution scanner (Siemens Medical Systems, Iselin, NJ, U.S.A.) | 6, 8, 10 | – | Custom software |
| Brown MS et al. 2010 | Breath-hold | Multicenter study with different scanners (GE, Siemens, Philips, Toshiba) | 5–10 | – | Custom made knowledge-based segmentation software |
| Chen F et al. | Breath-hold | multidetector Aquilion 64 CT scanner (Toshiba Medical Systems, Tochigi, Japan) | 0.5 | – | AZE Virtual Place Lexus workstation (AZE Ca, Ltd, Tokyo, Japan) |
| Coxson HO et al. | – | High-resolution CT, Multislice CT or thick slice protocol | 1, 1.25, 5 | – | Custom software (EmphylxJ, Vancouver, BC, Canada) |
| Daghighi A et al. | Breath-hold | SOMATOM Definition Flash, Siemens Medical Solutions, Forchheim, Germany | 4 | – | MIALite |
| Garfield JL et al. | Breath-hold | 16 or 64 MDCT scanner (Somatom Sensation; Siemens Medical Systems, Erlangen, Germany) | 0.75, 5 | – | Custom software (Pulmonary Workstation Plus, VIDA Diagnostics, Inc, Coralville, IA) |
| Gawlitza J et al. | Breath-hold | 3rd generation dual-source CT (Somatom FORCE, Siemens Healthineers, Forchheim, Germany) | 1.5 | – | Dedicated semiautomatic software (SyngoViaB10, Pulmo3D, Siemens Healthineers, Forchheim, Germany) |
| Jung WS et al. | Breath-hold | 128-slice (Somatom Definition AS+) or 64-slice (Somatom Sensation 64) or 16-slice (Somatom Sensation 16; Siemens Medical Solutions, Erlangen, Germany) multidetector CT | 3, 5 | – | Aquarius iNtuition version 4.4.6; TeraRecon, Foster City, CA |
| Kauczor HU et al. | Breath-hold | Unenhanced helical CT using Somatom Plus-S scanner (Siemens, Erlangen, Germany) | 8 | – | Pulmo-CT Siemens or Allegro workstation (ISG Technologies, Mississauga, Ontario, Canada) |
| Lacerda LS et al. | Breath-hold | 64-channel Multislice Philips system (Brilliance 40, Philips Medical Systems, Cleveland, Ohio) | 2 | – | OsiriX program (OsiriX 64-bits, Pixmeo Sarl, Geneva, Switzerland) |
| Matsumoto AJ et al. | Breath-hold | Multicenter, retrospective with different spiral-CT scanners (Siemens, GE, Imatron, Toshiba) | 1–5 | – | CALIPER |
| O’Donnell CR et al. | Hospital 1: Spirometric gating Hospital 2: Breath-hold Hospital 3: Breath-hold |
Three centers with spiral-CT scanners | – | – | Custom software |
| Schlesinger AE et al. | Breath-hold | Helical CT in 17 patients and conventional in remaining four (Somatom Plus S, Siemens, Erlangen, Germany) | – | – | Manual tracing |
| Shen M et al. | Breath-hold | 64-slice multiple-detector CT scanner (Somatom Sensation 64; Siemens, Erlangen, Germany) | 1 | – | The LungSeg Toolbox (The Hamlyn Centre, Imperial College London, UK) or Syngo CT Pulmo 3D (Siemens Healthineers GmbH, Erlangen, Germany) |
| Song L et al. | Breath-hold | Noncontrast multislice CT (MSCT) scanning (Light Speed Ultra 8 or Revolution EVO, both General Electric Healthcare, Chicago, IL, USA) | 0.625, 1.25 | – | MeVis PULMO3D software (v 3.7.1, Fraunhofer MEVIS, Bremen, Germany) |
| Tantucci C et al. | Spirometric gating with shutter occlusion | Multidetector CT scanner (Somatom Definition Flash, Siemens Medical Solutions, Forchheim, Germany) | 1 | 5.7 | Aquarius iNtuition version 4.4.6; TeraRecon, Foster City, CA |
| Wielpütz MO et al. | Breath-hold | 4-slice Volume Zoom helical computer tomograph (Siemens Medical Solutions AG, Forchheim, Germany) | 1.25 | – | YACTA (in-house software) or LowATT (Aquarius) or Pulmo 3D (Syngo.Via) |
| Wu F et al. | Breath-hold | 64-detector scanner (IQon Spectral CT, Philips Healthcare, Best, The Netherlands) | 1 | – | Philips IntelliSpace Portal post-processing workstation (version 12.0) using Chronic Obstructive Pulmonary Disease (COPD) analysis software |
| Zaporozhan J et al. | Breath-hold | 16-detector CT (Aquilion-16; Toshiba Medical Systems, Tochigi, Japan) | 1 | – | Self-written software (YACTA; Mainz, Germany) |
Funding Statement
There has been no funding for this work.
Data availability statement
The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request in anonymized form.
Disclosure statement
No potential conflict of interest was reported by the author(s).
References
- [1].O’Donnell CR, Bankier AA, Stiebellehner L, et al. Comparison of plethysmographic and helium dilution lung volumes: which is best for COPD? Chest. 2010;137(5):1108–12. doi: 10.1378/chest.09-1504 [DOI] [PMC free article] [PubMed] [Google Scholar]
- [2].West JB, Luks A.. West’s respiratory physiology : the essentials. 11th ed. Philadelphia: Wolters Kluwer; 2021. [Google Scholar]
- [3].Wanger J, Clausen JL, Coates A, et al. Standardisation of the measurement of lung volumes. Eur Respir J. 2005;26(3):511–522. doi: 10.1183/09031936.05.00035005 [DOI] [PubMed] [Google Scholar]
- [4].Moher D, Liberati A, Tetzlaff J, et al. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ. 2009;339(Jul21 1):b2535. doi: 10.1136/bmj.b2535 [DOI] [PMC free article] [PubMed] [Google Scholar]
- [5].Whiting PF, Rutjes AW, Westwood ME, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155(8):529–536. doi: 10.7326/0003-4819-155-8-201110180-00009 [DOI] [PubMed] [Google Scholar]
- [6].Gawlitza J, Trinkmann F, Scheffel H, et al. Time to exhale: additional value of expiratory chest CT in chronic obstructive pulmonary disease. Can Respir J. 2018;2018:1–9. doi: 10.1155/2018/9493504 [DOI] [PMC free article] [PubMed] [Google Scholar]
- [7].Bakker JT, Klooster K, Bouwman J, et al. Evaluation of spirometry-gated computed tomography to measure lung volumes in emphysema patients. ERJ Open Res. 2022;8(1):00492–2021. doi: 10.1183/23120541.00492-2021 [DOI] [PMC free article] [PubMed] [Google Scholar]
- [8].Brown MS, Kim HJ, Abtin F, et al. Reproducibility of lung and lobar volume measurements using computed tomography. Acad Radiol. 2010;17(3):316–322. doi: 10.1016/j.acra.2009.10.005 [DOI] [PubMed] [Google Scholar]
- [9].Kauczor HU, Heussel CP, Fischer B, et al. Assessment of lung volumes using helical CT at inspiration and expiration: comparison with pulmonary function tests. AJR Am J Roentgenol. 1998;171(4):1091–1095. doi: 10.2214/ajr.171.4.9763003 [DOI] [PubMed] [Google Scholar]
- [10].Shen M, Tenda ED, McNulty W, et al. Quantitative evaluation of lobar pulmonary function of emphysema patients with endobronchial coils. Respiration. 2019;98(1):70–81. doi: 10.1159/000499622 [DOI] [PubMed] [Google Scholar]
- [11].Song L, Leppig JA, Hubner RH, et al. Quantitative CT analysis in patients with pulmonary emphysema: do calculated differences between full inspiration and expiration correlate with lung function? Int J Chron Obstruct Pulmon Dis. 2020;15:1877–1886. 10.2147/COPD.S253602 [DOI] [PMC free article] [PubMed] [Google Scholar]
- [12].Wu F, Chen L, Huang J, et al. Total lung and lobar quantitative assessment based on paired inspiratory–expiratory chest CT in healthy adults: correlation with pulmonary ventilatory function. Diagnostics (Basel). 2021;11(10):1791. doi: 10.3390/diagnostics11101791 [DOI] [PMC free article] [PubMed] [Google Scholar]
- [13].Zaporozhan J, Ley S, Eberhardt R, et al. Paired inspiratory/expiratory volumetric thin-slice CT scan for emphysema analysis: comparison of different quantitative evaluations and pulmonary function test. Chest. 2005;128(5):3212–3220. doi: 10.1378/chest.128.5.3212 [DOI] [PubMed] [Google Scholar]
- [14].Barjaktarevic I, Springmeyer S, Gonzalez X, et al. Diffusing capacity for carbon monoxide correlates best with tissue volume from quantitative CT scanning analysis. Chest. 2015;147(6):1485–1493. doi: 10.1378/chest.14-1693 [DOI] [PubMed] [Google Scholar]
- [15].Tantucci C, Bottone D, Borghesi A, et al. Methods for measuring lung volumes: Is there a better one? Respiration. 2016;91(4):273–280. doi: 10.1159/000444418 [DOI] [PubMed] [Google Scholar]
- [16].Jung WS, Haam S, Shin JM, et al. The feasibility of CT lung volume as a surrogate marker of donor-recipient size matching in lung transplantation. Medicine (Baltimore). 2016;95(27):e3957. doi: 10.1097/MD.0000000000003957 [DOI] [PMC free article] [PubMed] [Google Scholar]
- [17].Garfield JL, Marchetti N, Gaughan JP, et al. Total lung capacity by plethysmography and high-resolution computed tomography in COPD. Int J Chron Obstruct Pulmon Dis. 2012;7:119–126. doi: 10.2147/COPD.S26419 [DOI] [PMC free article] [PubMed] [Google Scholar]
- [18].Schlesinger AE, White DK, Mallory GB, et al. Estimation of total lung capacity from chest radiography and chest CT in children: comparison with body plethysmography. AJR Am J Roentgenol. 1995;165(1):151–154. doi: 10.2214/ajr.165.1.7785574 [DOI] [PubMed] [Google Scholar]
- [19].Lacerda LS, Lopes AJ, Carvalho ARS, et al. The role of multidetector computed tomography and the forced oscillation technique in assessing lung damage in adults with cystic fibrosis. Respir Care. 2018;63(4):430–440. doi: 10.4187/respcare.05815 [DOI] [PubMed] [Google Scholar]
- [20].Chen F, Kubo T, Shoji T, et al. Comparison of pulmonary function test and computed tomography volumetry in living lung donors. J Heart Lung Transplant. 2011;30(5):572–575. doi: 10.1016/j.healun.2010.11.019 [DOI] [PubMed] [Google Scholar]
- [21].Wielpütz MO, Bardarova D, Weinheimer O, et al. Variation of densitometry on computed tomography in COPD–influence of different software tools. PLOS ONE. 2014;9(11):e112898. doi: 10.1371/journal.pone.0112898 [DOI] [PMC free article] [PubMed] [Google Scholar]
- [22].Matsumoto AJ, Bartholmai BJ, Wylam ME. Comparison of total lung capacity determined by plethysmography with computed tomographic segmentation using CALIPER. J Thorac Imaging. 2017;32(2):101–106. doi: 10.1097/RTI.0000000000000249 [DOI] [PubMed] [Google Scholar]
- [23].Coxson HO, Nasute Fauerbach PV, Storness-Bliss C, et al. Computed tomography assessment of lung volume changes after bronchial valve treatment. Eur Respir J. 2008;32(6):1443–1450. doi: 10.1183/09031936.00056008 [DOI] [PubMed] [Google Scholar]
- [24].Brown MS, McNitt-Gray MF, Goldin JG, et al. Automated measurement of single and total lung volume from CT. J Comput Assist Tomogr. 1999;23(4):632–640. doi: 10.1097/00004728-199907000-00027 [DOI] [PubMed] [Google Scholar]
- [25].Becker MD, Berkmen YM, Austin JH, et al. Lung volumes before and after lung volume reduction surgery: quantitative CT analysis. Am J Respir Crit Care Med. 1998;157(5 Pt 1):1593–1599. doi: 10.1164/ajrccm.157.5.9706066 [DOI] [PubMed] [Google Scholar]
- [26].Daghighi A, Tropp H. Computed tomography lung volume estimation and its relation to lung capacities and spine deformation. J Spine Surg. 2019;5(1):132–141. doi: 10.21037/jss.2018.12.14 [DOI] [PMC free article] [PubMed] [Google Scholar]
- [27].Yamada Y, Yamada M, Chubachi S, et al. Comparison of inspiratory and expiratory lung and lobe volumes among supine, standing, and sitting positions using conventional and upright CT. Sci Rep. 2020;10(1):16203. doi: 10.1038/s41598-020-73240-8 [DOI] [PMC free article] [PubMed] [Google Scholar]
- [28].Shore SA, Huk O, Mannix S, et al. Effect of panting frequency on the plethysmographic determination of thoracic gas volume in chronic obstructive pulmonary disease 1–3. Am Rev Respir Dis. 1983;128(1):54–59. doi: 10.1164/arrd.1983.128.1.54 [DOI] [PubMed] [Google Scholar]
- [29].Brenes GA. Anxiety and chronic obstructive pulmonary disease: prevalence, impact, and treatment. Psychosom Med. 2003;65(6):963–970. doi: 10.1097/01.PSY.0000097339.75789.81 [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request in anonymized form.


