Abstract
The exquisite precision of atom interferometers has sparked the interest of a large community for uses ranging from fundamental physics to geodesy and inertial navigation. However, their implementation for onboard applications is still limited, not least because rotation and acceleration are intertwined in a single phase shift, which makes the extraction of a useful signal more challenging. Moreover, the spatial separation of the wave packets due to rotations leads to a loss of signal. We present an atom interferometer operating over a large range of random angles, rotation rates and accelerations. A model of the expected phase shift allows us to untangle the rotation and acceleration signals. We also implement a real-time compensation system using fiber-optic gyroscopes and a rotating reference mirror to maintain the full contrast of the interferometer. We demonstrate a single-shot sensitivity to acceleration of 24 μg for rotation rates reaching 14° s−1.
Subject terms: Atom optics, Atomic and molecular interactions with photons
Cold atoms inertial sensors offer great precision and sensitivity, yet their use in mobile applications has been hindered by the effects of rotations on their measurements. Here, authors demonstrate an atom interferometer operating over a wide range of orientations and rotation rates, thanks to hybridisation with accelerometers and gyroscopes.
Introduction
Atom interferometers rely on the coherent splitting and recombination of the wave packets associated with an ensemble of laser-cooled atoms. When the atoms are in free-fall and manipulated by the field of a retroreflected laser beam, the interferometer becomes highly sensitive to accelerations and rotations1–8. This led to the development of novel inertial sensors with field9 and onboard implementations10–12, but further development is required to reach the full potential of atom interferometers and their applications in areas including fundamental physics13,14, geodesy15 and navigation16.
Rotations and accelerations both contribute to the phase shift of atom interferometers, and instruments are usually designed in a way that the sensitivity to one or the other is canceled out. For example, gravimeters are operated with a vertical laser beam such that there is no physical area leading to a rotation sensitivity17, and gyroscopes, using two counter-propagating atomic clouds, have been used to separate rotations from accelerations4,18–20. When the sole configuration of the experiment is no longer sufficient to separate the effect of rotations and accelerations, these techniques are sometimes extended. This is, for example, the case in long-baseline atom interferometers, where the rotation of the Earth can result in spurious phase shifts and contrast losses. This effect can be mitigated by applying a rotation to the reference mirror, which retroreflects the laser beam21,22. However, this separation of acceleration and rotation cannot be implemented in the case of strap-down onboard applications because it relies on a static operation of the inertial sensor, where the geometry of the matter-wave interferometer is known and constant in time. Even in the architectures where rotations are compensated, this is done using a priori knowledge of the rotation rate23,24. In the case of a moving carrier, this is no longer possible, and both accelerations and rotations will play a significant part in the measurement.
Here, we present a new method to independently measure random rotation and acceleration at high rotation rates while preserving the full contrast of the atom interferometer. This is achieved by hybridizing with classical inertial sensors, enabling the separate extraction of rotation and acceleration information that are simultaneously present during the inertial measurement. We report on the operation of an atom interferometer over a large angle range [0, 30]° and for high rotations rates up to 250 mrad s−1 (14° s−1).
First, we implement a double hybridization of our single-axis atom interferometer with a classical accelerometer and two fiber-optic gyroscopes (FOG) and demonstrate a quantitative understanding of the atomic phase shift due to rotations while the phase shift due to acceleration is canceled out thanks to a real-time closed-loop servo-lock. This method is validated over an intermediate range of rotation rates where the contrast is not fully canceled by the spatial separation of the wave packets. Then, for higher rotation rates, we apply a real-time compensation of the orientation of the reference mirror, using the FOGs’ signals to maintain the effective wavevector of the laser along a constant direction and thus ensure the overlap of the wave packets at the output of the atom interferometer. We extend our model of the expected phase shift to fully reconstruct the atomic fringes of our hybrid quantum sensor.
Results
Our experiments are performed on a three-axis hybrid atom interferometer setup, installed on a manual three-axis rotation platform and capable of measuring accelerations along three orthogonal directions as described in ref. 25.
An ensemble of rubidium 87 atoms is trapped and cooled down to a temperature of approximately 4 μK. The atoms are then released and prepared in the magnetically insensitive sub-level of the 52S1/2 ground state. Following a time of flight TTOF, a sequence of three counter-propagating Raman pulses (π/2 − π − π/2), each separated by the interrogation time T, is carried out to coherently split, reflect, and recombine atomic wave packets and perform a Mach-Zehnder interferometer. A state-sensitive fluorescence detection allows us to measure the atom number in the hyperfine level as well as the total atom number, respectively denoted as N2 and Ntot. The interferometer’s output signal is the population ratio R = N2/Ntot at the end of the sequence.
Here, we perform interferometry along a single-axis z and define the reference angle θ = 0° when this axis is vertical, i.e. aligned with gravity. Classical accelerometers attached to the back of the retroreflection mirrors (Fig. 1) on each axis provide the signals necessary to calculate the laser phase and frequency shifts required to compensate for the tilt-dependent Doppler effect and the noise due to vibrations of the reference mirror25. For all the data presented in this paper, the phase shift due to acceleration is canceled out in a closed-loop mode as demonstrated in ref. 25 and described in the Methods. The present study focuses on the phase shift due to rotation.
Fig. 1. Schematic representation of the rotating atom interferometer.
Three orthogonal laser beams are used to trap and cool an ensemble of 87Rb atoms in a retroreflected configuration. Mechanical accelerometers are attached to the back of the three mirrors and two fiber-optic gyroscopes (FOG) measure the rotations of the device along the x and y axes. The atom interferometer is performed on the z axis, where the reference mirror is mounted on a piezoelectric tip-tilt platform. The experiment rotates with a rotation axis x and a rotation rate Ω. The tilt angle of the experiment is θ = 0° when the axis z is vertical, i.e. aligned with gravity. Inset: the two modes of operation of the tip-tilt mirror represented by a spatio-temporal diagram. In the rigid mode, the tip-tilt behaves like a fixed mirror and follows the rotation of the device. In the inertial pointing mode, the mirror keeps a constant orientation in the frame of the laboratory for the duration of the interferometer (2T).
Two fiber-optic gyroscopes measure the rotation rates around the x and y axes. These FOGs, adapted from a rotational seismometer (Exail — formerly iXblue — BlueSeis 3A), are capable of measuring angular velocities up to 667 mrad s−1 (~38° s−1) with a noise below 100 nrad s−1 Hz−1/2. The device rotates around the x axis, orthogonal to the measurement axis z. On the z axis, the reference mirror is mounted on a two-axis piezoelectric tip-tilt platform (Physik Instrumente S-335.2SHM2) in order to dynamically control its orientation. We neglect Earth’s rotation which is three to four orders of magnitude below the rotation rate of the device.
Contrast loss and phase shift of a rotating atom interferometer
In this section, the orientation of the mirror remains fixed with respect to the vacuum chamber (rigid mode in Fig. 1). The rotation of the device impacts both the contrast and the phase of the Mach-Zehnder atom interferometer, leading to the measured population ratio:
| 1 |
where R0 is the offset of the interference fringes, ϕr(Ω) the phase shift due to the rotation of the experiment and C(Ω) the contrast measured for a rotation rate Ω.
The rotation of the atom interferometer changes the direction of the laser beam, and therefore, the direction of the momentum transferred to the atoms between two consecutive pulses. This angle leads to a separation in position and momentum of the wave packets associated with the two arms of the interferometer and, as a consequence, to a loss of contrast of the interference fringes26:
| 2 |
where C0 is the static contrast of the interferometer, i.e., when there is no rotation, the temperature of the atomic cloud, kB, the Boltzmann constant, m, the mass of the atom and keff, the effective wavevector of the Raman transition.
The phase term ϕr in equation (1) is impacted by the complex trajectory of the free-falling atoms in the reference frame of the rotating laser beam. This leads to phase shifts which are not compensated for by the hybridization with the classical accelerometer. Using the mid-point theorem27, we have carried out a derivation of the rotation-induced phase term in the rigid mode (see Methods and ref. 28). Here, we assume the rotation rate Ω and the angle θ between the laser beam and the vertical defined by gravity to be constant during the atom interferometer. We also assume that the atoms have no initial velocity when they are released from the optical molasses.
Neglecting the duration of the Raman pulses, we find:
| 3 |
where g is the free-fall acceleration of the atoms under the effect of gravity (g ≃ −9.806 m s−2), denotes the distance between the atomic wave packet and the classical accelerometer at the beginning of the interferometer, TTOF the time of flight before the first interferometer pulse. We find for θ = 0° and TTOF = 20 ms (see Methods). The first term in this expression corresponds to a differential centrifugal acceleration between the classical accelerometer and the atom interferometer due to the different positions of their respective test masses. The second term of equation (3) is akin to a Coriolis acceleration and depends on the velocity component of the atoms perpendicular to the direction of propagation of the laser. For significant tilts (θ ≳ 3°), this term is the dominant one with the typical parameters of our experiment. Both terms are factored by the scale factor of the atom interferometer keffT2. For numerical applications, the average values of θ and Ω during the interferometer are used. Note that this model does not take into account terms associated with a tangential acceleration of the atoms which depends on the angular acceleration of the device (see Methods).
The data presented in Fig. 2 (left) show the population ratio R measured at the output of the rotating atom interferometer, as a function of the angular velocity. The result includes ~1600 measurement cycles with an interrogation time 2T = 12 ms, angular velocities up to 150 mrad s−1 (8. 6° s−1) and tilts of the device between 0° (vertical) and +30°. A constant π/2 phase offset of the laser is applied on the last pulse of the interferometer, which is why R ≈ 0.5 for Ω = 0. The rotation rate of the device is directly given by the measurement of the gyroscope, while the angle θ is calculated from the accelerometer’s signal. The gyroscopes are sampled at 1 kHz and the accelerometers at 2.5 kHz, allowing us to average out the inertial signals over the duration of the interferometer and reduce the influence of electronic noise. The distribution of the data points highlights the loss of contrast for increasing angular velocities. The points are contained in an envelope (dashed red line) defined by R0 ± C(Ω)/2 (Eq. (2)). For a given rotation rate, different tilt angles, which determine the initial transverse velocity of the atoms, lead to different rotation-induced phase shifts, hence the variation in the measured population ratio.
Fig. 2. Rotating atom interferometer in the rigid mode.
Population ratio N2/Ntot as a function of the rotation rate of the device. Left: 1600 measurements with θ ∈ [0, 30]°, 2T = 12 ms. The dashed red line is an envelop defined by R = R0 ± C(Ω)/2. Right: Output of the atom interferometer for a tilt angle θ ∈ [11, 13]° (blue) and θ ∈ [27, 30]° (red). The solid lines are the theoretical curves calculated using equations (1), (2) and (3). The shaded regions correspond to the model values for the extrema of the angle ranges.
We can further analyze the data for a given tilt of the experiment. Selecting data points corresponding to a small range of tilt angles centered around , the interference pattern becomes clearly visible and the data show a very good agreement with our model, with no adjustable parameter (Fig. 2, right). The periodicity of the fringes is determined by the initial transverse velocity and, therefore, in the present case, by the tilt angle, as expected for an atomic gyroscope. This shows that our model is an accurate description of the atom interferometer in the presence of rotations, both for contrast loss and the phase terms, within the parameters of our experiment. Moreover, the direct correlation of the atomic signal with the output of the fiber-optic gyroscope proves we are able to extract the rotation signal from a single atomic measurement while retrieving the acceleration signal of the hybrid accelerometer working in a closed-loop mode (see ref. 25 and Methods).
In this rigid mode and for our atomic temperature and interrogation time, the operation of the atom interferometer is limited to rotation rates up to 85 mrad s−1 (5° s−1) approximately because of the contrast loss. To extend the range of accessible rotation rates and increase the interrogation time, we implement a real-time compensation consisting in maintaining the pointing direction of the reference mirror constant to preserve the overlap of the wave packets and therefore the contrast of the interferometer.
Extension of the dynamic range to higher rotation rates
In order to perform atom interferometry at higher rotation rates, the orientation of the reference mirror in the laboratory frame is kept constant for the duration of the interferometer to maintain the contrast. To that end, we use the signals from the FOGs to control a piezoelectric tip-tilt platform on which the reference mirror is mounted and perform a rotation of the mirror of equal amplitude and opposite direction to the rotation of the device (inertial pointing mode in Fig. 1).
This real-time, active compensation of the rotation consists of applying two angle steps to the tip-tilt platform after the first and second Raman pulses, respectively, in order to keep the orientation of the mirror constant in the inertial frame. After the first pulse, a measurement of the rotation rate is performed by the gyroscopes and sent to a field-programmable gate array (FPGA) that calculates the angle step the mirror should make before the second pulse to cancel this rotation. The calculated setpoint is then sent to the tip-tilt platform to adjust its position. The same procedure is repeated after the second Raman pulse to adjust the position of the mirror before the third and last Raman pulse such that the orientation of the mirror in the laboratory frame remains the same when the laser pulses are applied. This method of compensation is based on the assumption that the rotation rate of the device is constant between two pulses of the interferometers. Figure 3 (top) shows that it is very effective to maintain the fringes’ contrast for an interrogation time 2T = 20 ms and angular velocities up to, at least, 250 mrad s−1 (14° s−1).
Fig. 3. Rotating atom interferometer in the inertial pointing mode.
Top: normalized contrast C(Ω)/C0 (C0 is the contrast for a static interferometer) of interference fringes as a function of the rotation rate during the interferometer. The red lines give the contrast calculated with equation (2) for a temperature of 4 μK. The black dots represent experimental measurements of the contrast with a constant rotation of the reference mirror for T = 5 and 10 ms and a static device. The blue points show the measured contrast when the rotation compensation is active for 2T = 20 ms. Because we apply random rotation rates with our manual rotation platform, we group individual interferometers into intervals of rotation rates (30 to 50 mrad s−1 wide) and take the average value on each interval. Each interval contains the result of 600 to 1000 interferometers, and the contrast is determined from the histogram of the measured population ratios. The large horizontal error bars represent the standard deviation of the rotation rate on these intervals. Bottom: Population ratio R as a function of the rotation phase, calculated with equation (4) from the experimental parameters with θ ∈ [0, 30]°, Ω ∈ [−250, 250] mrad s−1 and a correction factor ε = −0.013 on the rotation rate of the mirror (see text). The blue curve is a sinusoidal fit to the data points.
The rotation of the reference mirror effectively addresses the drop in the visibility of the atomic fringes but also strongly reduces the phase shift associated with the Coriolis acceleration. However, it also leads to additional phase shifts related to the angular velocity of the mirror in the rotating frame of the device, denoted as Ωm.
With the same assumptions as for the rigid mode, the phase shift due to the rotations, which depends on the rotation rates Ω and Ωm and the tilt θ, is:
| 4 |
where we have introduced , the distance between the atomic cloud and the reference mirror at the beginning of the interferometer and dm, the distance between the mirror’s center of rotation and the surface of the mirror. Note that the first term in this expression, which corresponds to the Coriolis acceleration due to the residual rotation of the mirror in the inertial frame, is close to zero as Ωm ≈ −Ω. The term accounts for the changes in orientation and norm of the effective wavevector; the latter being a consequence of an overlap mismatch between the incident and reflected beams. The two terms in Ω2 and of equation (4) correspond to the centrifugal accelerations linked to the rotations of the device and of the mirror. The last term arises from the successive changes of frame of reference.
To assess the validity of our rotation phase model in inertial pointing mode, 1400 shots were performed for an interrogation time 2T = 20 ms, rotation rates up to 250 mrad s−1 (~14° s−1) and tilts between 0° and 30°. The atomic interference pattern is reconstructed by plotting the population ratio as a function of the rotation-induced phase calculated from equation (4) (Fig. 3, bottom).
Ideally, the angular velocity of the mirror should perfectly compensate the rotation of the device: Ωm = −Ω. However, because we have no direct measurement of the mirror’s effective angular velocity Ωm, we introduce a correction factor in our model to take into account a possible discrepancy between the desired and effective rotation rates, and make the substitution Ωm→(1 + ε)Ωm in equation (4) (see Methods). An optimal reconstruction is found for ε = −0.013. The signal-to-noise ratio (SNR) of the reconstructed fringes, defined as the ratio of the fringes’ contrast over the standard deviation of the fit residuals, is 5.3, which corresponds to an acceleration sensitivity 2/(SNR ⋅ keffT2) = 2.34 ⋅ 10−4 m s−2 (=24 μg) per shot. For comparison, the signal-to-noise ratio in static conditions is between 20 and 30 over the full angle range [0, 30]°, for the same interrogation time. We believe that this drop in SNR is due to a degradation of the vibration correction, coming from the excitation of vibration modes of the platform when the device is rotating. This effect can be reproduced by exciting the vibration modes in a non-rotating operation (see Methods).
Discussion
We have demonstrated the operation of an atom interferometer over a large range of angles ([0, 30]°) and rotation rates up to 14° s−1, in a regime compliant with operational utilization aboard many platforms (undersea, sea, air, and space). The hybridization of the atom interferometer with mechanical accelerometers and optical gyroscopes combined with an accurate model of the expected phase shift allows us to untangle the acceleration and rotation contributions. For high rotation rates, we implemented a real-time compensation of the reference mirror’s orientation using a tip-tilt platform and the signal provided by the gyroscopes, thus expanding the range where the contrast of the atom interferometer is maintained. A sensitivity to acceleration of 24 μg can be extracted from the reconstructed fringes, for a total interrogation time of 2T = 20 ms, with a technical limitation arising from the vibrations compensation but not from the rotations of the instrument themselves.
The manual operation of our rotation platform limits the accessible range of rotation rates, and the increased vibrations at higher velocities make the fringe reconstruction more difficult. Nevertheless, we have not noticed any significant drop in the interferometer’s contrast, even for rates higher than 14° s−1, which suggests the technique we have implemented should only be limited, in this regard, by the maximum angle achievable by the tip-tilt platform.
These results and our ability to reconstruct the full acceleration vector for arbitrary orientations in a quasi-static configuration25, show we have the tools necessary to operate quantum inertial sensors based on cold atoms in highly dynamic environments and pave the way for high-performance onboard measurements.
To reach our long-term goal of a full quantum strapdown three-axis accelerometer, our rotation compensation system can be extended to a triad including three tip-tilt mirrors and three gyroscopes. The high bandwidth and continuity of the measurement are ensured by the hybridization of the classical sensors and will be pushed forward. Future studies will look into the long-term stability of the three-axis sensor, as well as the systematic errors and effects related to the rotation of the instrument, including transverse motion of the atoms in the laser beams and inhomogenities in the detection. The full validation of this strapdown strategy can lead to practical applications such as the improvement of gravity maps, in situ calibration of inertial navigation systems, geodesy as well as space-borne applications. Indeed, the dynamic range being defined by the combination of the interrogation time and angular velocity, the same models could be applied in a regime of significantly longer interrogation times and slower rotations29.
Additionally, our experiment paves the way toward the first onboard atomic gyroscope, working from any angle. The correlation of the phase shift due to rotation with a fiber-optic gyroscope is a first step towards a high dynamic, continuous hybrid quantum gyroscope. This is a true alternative to thermal atomic beams23,30 and point source interferometers31.
Methods
Here, we detail the real-time compensation of the acceleration in the closed-loop mode and the limits of the fringe reconstruction due to mechanical modes excitation when the device is rotating. We also present the derivation of the rotation-induced phase shift, both for the rigid and inertial pointing modes. We then explain our method to determine the lever arms, and finally, we discuss the correction ε of the phase shift in the inertial pointing mode.
Closed-loop mode: real-time compensation of vibrations and Doppler effect
General principle
We have developed a closed-loop operation of our hybrid atom interferometer, using the classical accelerometers to extend the dynamic range and bandwidth of the quantum sensor, while benefiting from the latter’s intrinsic high long-term stability. We recall the main ideas for the understanding of the present article. Details can be found in ref. 25.
To keep the Raman laser on resonance as the atoms fall, it is necessary to compensate for the Doppler frequency shift caused by the acceleration of the atoms relative to the reference mirror. This shift depends on the orientation of the laser beam with respect to the vertical direction. We use the classical accelerometers installed on the device to determine its orientation by measuring the projections of the gravity vector and applying an appropriate correction on the laser phase and frequency for any orientation of the device, thanks to an FPGA-based, real-time feedback system.
We also use the signal of the classical accelerometer installed along the z axis to record the vibrations of the reference mirror, and apply a corresponding correction to the laser phase before the final Raman pulse of the interferometer32.
Combining these two techniques, we operate the hybrid accelerometer in a closed-loop configuration where the comparison of the classical and quantum acceleration measurements allows us to isolate and correct for the intrinsic bias of the classical device.
Owing to this real-time phase compensation technique, the vibrations and change in orientation do not produce any phase shift on the interference fringes, and the results presented in this paper include only rotation-induced phase shifts.
Limits of the fringe reconstruction due to strong vibrations
The efficiency of the real-time vibration compensation scheme is limited by the performances of the classical accelerometer (Thales MICAL) attached to the back of the reference mirror, and in particular, its bandwidth and self-noise, for which we do not have precise characterizations. Our real-time compensation technique also has a limited signal processing capability, meaning that we are not able to compensate for variations in the response function of the accelerometer over the frequency spectrum of interest32. We simply assume that the amplitude response is constant, and we apply a global delay of 610 μs to the acceleration to compensate for the mean phase of the system. This method has proven to be efficient when the vibration spectrum is either close to white noise or centered around a narrow frequency band because the delay corresponds to a perfect phase compensation for a single given frequency33. Furthermore, in our current setup, the friction generated by the motion of the device and counterweight on the rotation axis of the rotation platform produces high amplitude resonances, especially in the 10–100 Hz range, as can be seen on the red curve in Supplementary Fig. 1. Because there are several distinct resonances, our compensation method leads to an imperfect rejection of vibrations over this frequency range and a significant reduction in the signal-to-noise ratio of the interference fringes and acceleration sensitivity.
In order to estimate the effect of these rotation-induced vibrations, we attempted to reproduce the acceleration noise spectrum obtained in the presence of rotations with a static device. We gently tap the rotation platform to excite its resonance modes while recording atom interference fringes. Under these experimental conditions, represented by the blue curve in Supplementary Fig. 1, the signal-to-noise ratio of the atomic fringes dropped to 6.2 with a fitted contrast of 27%. In comparison, the reconstruction of the interference pattern obtained under strong rotations in an inertial pointing configuration yielded a signal-to-noise ratio of 5.3 and a contrast of 32%. The similarity of these results suggests that our performances are strongly limited by the vibration noise, even when the instrument is rotating.
Theoretical model of the rotation-induced phase shifts
In the case of a potential at most quadratic in position and momentum, the phase shift accumulated between the two arms of the atomic interferometer A and B can be described by the mid-point theorem27,34. In a Mach-Zehnder geometry, this phase shift simplifies the expression
| 5 |
with i the index of the atom-light interaction, kA,i (respectively kB,i) the wavevector of the laser along the arm A (respectively B) of the interferometer and
| 6 |
the position of the center of mass of the two wave packets at the ith laser pulse. The full phase shift of the atom interferometer undergoing random accelerations and rotations is estimated by calculating the position of the atoms with respect to the reference mirror at the instant of the laser pulses while taking into account the time evolution of the effective wavevector’s norm and orientation. To this end, we carry out calculations in the mobile frame of the device.
In our calculations, we neglect Earth’s rotation and assume that the atoms only fall under the action of gravity, leading to the Lagrangian of a free-falling atom in the laboratory frame:
| 7 |
with v0 and r0 the velocity and position of the atom in the laboratory frame. We then operate a velocity transformation to write the Lagrangian in the mobile frame:
| 8 |
with ΩM(t) the rotation rate of the device (simply written Ω(t) below to simplify notations) and a(t) the linear acceleration of the atoms relative to the device which can be decomposed as a(t) = g − aM(t). The term aM(t) includes both the DC component of the sensor’s acceleration as(t) and vibrations avib(t). vM(t) and rM(t) are the velocity and position of the atoms in the mobile frame. Taking the origin of this frame at the mobile’s center of rotation, which belongs to both inertial frames, all velocities and positions are defined with respect to this point, and we can write r(t) ≔ r0(t) = rM(t). We have:
| 9 |
| 10 |
Calculating the derivatives of the Lagrangian with respect to the atom’s position and velocity and using the Euler-Lagrange equation leads to the equation of motion:
| 11 |
where we recognize on the left-hand side in order of appearance, the relative, Coriolis, centrifugal and tangential accelerations, the latter two forming what is called the driving acceleration. To solve this equation and calculate the atomic trajectories we use a polynomial decomposition of the atoms’ position (r(t) = ∑j ≤ 3cj × t j), considering, at first, constant accelerations and rotation rates and truncating to third-order terms. Ultimately, we will consider in the following only rotations with axes in the plane transverse to the effective wavevector of the laser .
All the inertial components, namely acceleration, velocity and position of the atomic wave packet relative to the reference mirror are defined with respect to their values at the instant of the first laser pulse (taken as initial conditions). Acceleration is considered constant, and velocity can be computed from the moment the atoms are released from the optical molasses, since the atoms are trapped and have no relative velocity in the frame of the experimental chamber prior to this point.
Then, as mentioned above, calculating the phase delay accumulated between the two arms A and B of the interferometer can be achieved by using the mid-point theorem written as
| 12 |
with keff(t), rat(t) and rm(t) the effective wavevector of the laser, the position of the atoms and the position of the mirror at the instant t respectively. The superscripts A, B on the atomic cloud’s position vectors denote the interferometer’s path they follow.
Phase shift in rigid mode
Assuming the reference mirror is immobile in the device’s reference frame such that the effective wavevector’s norm and orientation remain constant in that frame and, setting k(t) = keff. uz so that only rotations on the x and y axes will appear, the phase shift at the output of the interferometer calculated using the mid-point theorem is:
| 13 |
with and under the assumption of infinitely short laser pulses. Here, we recognize the relative acceleration, two Coriolis terms, and a last term corresponding to the centrifugal acceleration.
Due to our hybridization scheme (see Methods and ref. 25), the measurement of the classical accelerometer attached to the reference mirror is subtracted in real-time from the atomic acceleration. To account for this, one can define an equivalent phase shift from the classical acceleration using the formalism of the sensitivity function35. This method yields a phase shift equal to
| 14 |
considering that the classical sensor, fixed in the experimental chamber’s frame, has no relative velocity . The subtraction of the two expressions in equations (13) and (14) finally gives us the inertial phase shift remaining to be compensated for:
| 15 |
where denotes the initial distance between the atomic wave packet and the classical accelerometer along the z axis.
Phase shift in inertial pointing mode
Here we calculate the phase shift for the inertial pointing mode, where we apply a rotation to the mirror in order to keep the orientation of the Raman wavevector constant in the frame of the laboratory. The contributions to the atomic phase shift are summarized in Supplementary Table 1 where we have introduced the squared norm of the mirror’s rotation rate and dCOR the distance between the center of rotation of the chamber and of the mirror, respectively. The total phase shift is the sum of all these contributions. Note that the rotation of the mirror cancels out the Coriolis effect almost entirely (Ωi ≃ −Ωmi) and is at the origin of additional terms in the centrifugal acceleration.
Since the mechanical accelerometer is not sensitive to the rotation of the mirror, the terms subtracted from the previous expression are the same as in equation (14). To simplify notations, we will write:
the distance between the classical sensor and the atomic wave packet at the instant of the first pulse,
the distance between the atomic cloud and the reference mirror’s surface at the same time,
δΩi = Ωi + Ωmi (i = x, y) the residual rotation rate on a given axis arising from an imperfect compensation.
The expression of the phase shift in the closed-loop mode with the classical sensor becomes:
| 16 |
Tangential acceleration
The derivations of the phase in the rigid (Eq. (15)) and inertial (Eq. (16)) modes were made with the assumption that the angular velocity of the device is constant. If we now consider that the angular velocity varies at most linearly with time, a tangential acceleration of the atoms, related to the angular acceleration , will result in an additional phase shift:
| 17 |
The instantaneous angular acceleration can be estimated by calculating the gradient between two successive measurements of the fiber-optic gyroscopes. An average value over the duration of the interferometer can then be used to calculate the phase term associated with the tangential acceleration. For the data set in inertial pointing mode, the measured angular accelerations follow a Gaussian distribution centered on zero with a standard deviation of 72 mrad s−2. We find that, in our experiments, this term has a small influence on the overall rotation-induced phase shift — the phase shift associated with the angular acceleration is one or two orders of magnitude below the total phase shift — and produces no significant difference in the analysis of the data.
For more general cases, with a significant time dependence of the rotation rate during the atom interferometer, it is possible to use a temporal response function to model the expected phase shift36. Our goal is to develop a method which can be implemented in real-time, with our FPGA for instance. The simple approach of our article is easier to implement than the temporal response function which is consequently beyond the scope of this work.
Determination of the lever arms
The centrifugal accelerations in the phase shifts of equations (15) and (16) require evaluating different lever arms on the apparatus, namely the distances dm, and .
The distance dm between the surface of the mirror and its center of rotation is a property of the tip-tilt device and is given by its datasheet (dm = 7 mm).
To determine the position of the cloud with respect to the mirror at the beginning of the interferometer (), we apply a frequency jump Δf to the laser at the π pulse of a Mach-Zehnder interferometer (without rotations), which introduces an additional phase shift equal to37:
| 18 |
with dπ the distance between the atomic cloud and the reference mirror at the instant of the π pulse and c the speed of light. The distance dπ is extracted from the measured phase shift as a function of the applied frequency shift. The position of the atomic cloud when released from the MOT is obtained by adding dπ to the distance traveled by the atoms up to the second pulse of the interferometer. This operation is repeated for different frequency jumps and times of flight to find a reference position: .
The distance is then calculated for each data point by summing and the distance traveled before the first interferometer pulse, taking into account the time of flight of the atoms before the interferometer and the tilt angle of the device .
Finally, the distance between the atoms and the proof mass of the classical accelerometer is calculated by adding to the distance between the accelerometer and the mirror which is known from the mechanical drawings of the experiment and the datasheet of the accelerometer: .
Correction of the phase shift in the inertial pointing mode
The calculation of the rotation phase in the inertial pointing mode reveals an anomaly in the reconstructed interference pattern. Supplementary Fig. 2 shows the population ratio measured at the output of the interferometer as a function of the rotation phase calculated with equation (4) when no correction is performed. This interferogram clearly exhibits a sinusoidal pattern but not with the expected 2π-periodicity. This shows that the evaluation of the phase shift is not perfect, even if the periodicity of the reconstructed fringes indicates a strong correlation between the true and estimated phase shifts. We therefore look at the potential systematic errors in the determination of the experimental parameters: the tilt angle θ, the device’s rotation rate Ω, and the mirror’s rotation rate Ωm.
For each of them, we evaluate the error that would explain our signal, and rule out the ones which are incompatible with independent estimations. We find that all the suspected effects can be rejected, except for a calibration error of the tip-tilt mirror.
Tilt angle
The tilt θ of the experiment with respect to gravity determines the transverse velocity of the atoms and intervenes in several terms of the phase shift. This angle is calculated from the measurements of the classical accelerometers of the device. To evaluate the effect of an error in the measurement of the tilt angle, we make the substitution θ → (1 + ε)θ in the expression of the phase shift. For each value of ε, the corrected data is fitted with a sinusoidal function for which the contrast and offset are fixed, while the period and phase are the fitting parameters. We keep the value ε leading to a 2π-periodic signal and find ε = −0.103.
We can reject this error on the tilt angle for two reasons. First, the measurement of the angle from the accelerometers is consistent with the goniometer of our rotation platform, whereas such a large error (10% corresponds to 3° at 30°) would be clearly visible. Second, this error disagrees with the analysis done in the rigid mode. Introducing a 10% error on the tilt angle for the rigid mode leads to a severely degraded reconstruction of the interference pattern.
Scale factor of the gyroscopes
The rotation rate of the device is directly measured by the fiber-optic gyroscopes. An error in the scale factor of the gyroscopes will lead to a systematic error in the calculation of the rotation-induced phase shift, which could explain our observations on the interferogram. Now performing the substitution Ω → (1 + ε)Ω, we find that a correction ε = 0.016 allows us to retrieve a 2π-periodicity. Nevertheless, the scale factors of the gyroscopes have been characterized with a 10−5 relative precision, which is much smaller than the discrepancy we find. We, therefore, exclude this from the list of possible sources of error.
Mismatch of tip-tilt and device axes
The tip-tilt mirror rotates around two axes which are determined by the position of its piezoelectric actuators. These axes are at an angle γ ≈ 45° with respect to the measurement axes of the fiber-optic gyroscopes on the device. An error on the angle γ leads to an imperfect compensation of the device’s rotation. This, in turn, produces a non-zero Coriolis phase shift as the motion of the mirror in the inertial frame of reference is not a pure translation. In the general expression of the rotation-induced phase (Eq. (16)), this corresponds to the term 2(vx + axT)δΩy − 2(vy + ayT)δΩx.
We thus assume an error on the angle γ and calculate the corresponding values of δΩx and δΩy to reconstruct the interference pattern. We also allow for a non-zero initial velocity along the x direction (vx). Using the same criterion of 2π-periodicity as above, we find an optimum for an error of δγ ≈ 9° which is too large a value to be credible. From design and independent measurements we estimate δγ = ±2° at most.
Scale factor of the tip-tilt mirror
If the scale factor of the tip-tilt mirror (angular displacement versus set voltage) is not perfectly calibrated, there could be a discrepancy between the desired and effective rotation rate of the mirror that would lead to errors in the calculated phase shift (Eq. (16)).
Making the substitution Ωm → (1 + ε)Ωm in the expression of the phase shift, we find an optimal correction of the fringes’ periodicity for ε = −0.013.
We have carried out an optical characterization of the mirror by shining a laser on the mirror and measuring the displacement of the reflected beam on a position sensitive photodiode. These measurements are compatible with the expected value of the correction factor ε, with a precision at the 1% level. A more accurate measurement is required to confirm the calibration error of the tip-tilt mirror. It is, however, our favored hypothesis to explain the observed anomaly in the reconstructed fringes in the inertial pointing mode.
Supplementary information
Acknowledgements
This work is supported by the French national agency ANR (Agence Nationale pour la Recherche) under grant no. ANR-20-CE47-0008 MiniXQuanta and PEPR (Programmes et Equipements Prioritaires de Recherche) France Relance 2030 QAFCA grant no. ANR-22-PETQ-0005 QAFCA. We acknowledge support from the Naquidis Center (VEGA project). V.M. acknowledges support from the France Relance initiative.
Author contributions
P.B. and B.B. conceived the project. Q.A.C. and S.T. built the apparatus, Q.A.C., S.T., and R.A. designed and implemented the rotation compensation system, Q.A.C., C.D.C., and B.B. worked out the theoretical model of the phase shift with contributions from V.J. and V.M., Q.A.C., C.D.C., and V.J. performed experiments, Q.A.C., and V.J. carried out the data analysis. B.B. and V.M. supervised the experiments, data analysis, and calculations. B.B., B.D., P.B., and V.M. coordinated and administrated the project. B.B., Q.A.C., V.J., and V.M. wrote the manuscript. All authors discussed and reviewed the manuscript.
Peer review
Peer review information
Nature Communications thanks the anonymous reviewers for their contribution to the peer review of this work. A peer review file is available.
Data availability
The raw data generated in this study have been deposited in the Zenodo database with the reference 11543715.
Competing interests
Exail is a subsidiary of Exail Technologies SA, a listed company that commercializes quantum gravimeters based on atom interferometry. Simon Templier, Vincent Jarlaud, Vincent Ménoret, and Bruno Desruelle are currently employed by Exail. The other authors declare that they have no competing interests.
Footnotes
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
The online version contains supplementary material available at 10.1038/s41467-024-50804-0.
References
- 1.Geiger, R., Landragin, A., Merlet, S. & Pereira Dos Santos, F. High-accuracy inertial measurements with cold-atom sensors. AVS Quantum Sci.2, 024702 (2020). 10.1116/5.0009093 [DOI] [Google Scholar]
- 2.Kasevich, M. A. & Chu, S. Atomic interferometry using stimulated Raman transitions. Phys. Rev. Lett.67, 181 (1991). 10.1103/PhysRevLett.67.181 [DOI] [PubMed] [Google Scholar]
- 3.Merlet, S. et al. Comparison between two mobile absolute gravimeters: optical versus atomic interferometers. Metrologia47, L9–L11 (2010). 10.1088/0026-1394/47/4/L01 [DOI] [Google Scholar]
- 4.Gustavson, T. L., Bouyer, P. & Kasevich, M. A. Precision rotation measurements with an atom interferometer gyroscope. Phys. Rev. Lett.78, 2046–2049 (1997). 10.1103/PhysRevLett.78.2046 [DOI] [Google Scholar]
- 5.Lenef, A. et al. Rotation sensing with an atom interferometer. Phys. Rev. Lett.78, 760–763 (1997). 10.1103/PhysRevLett.78.760 [DOI] [Google Scholar]
- 6.Dutta, I. et al. Continuous cold-atom inertial sensor with 1 nrad/s rotation stability. Phys. Rev. Lett.116, 183003 (2016). 10.1103/PhysRevLett.116.183003 [DOI] [PubMed] [Google Scholar]
- 7.Savoie, D. et al. Interleaved atom interferometry for high-sensitivity inertial measurements. Sci. Adv.4, eaau7948 (2018). 10.1126/sciadv.aau7948 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Chen, Y.-J. et al. Single-source multiaxis cold-atom interferometer in a centimeter-scale cell. Phys. Rev. Appl.12, 014019 (2019). 10.1103/PhysRevApplied.12.014019 [DOI] [Google Scholar]
- 9.Antoni-Micollier, L. et al. Detecting volcano-related underground mass changes with a quantum gravimeter. Geophys. Res. Lett.49, e2022GL097814 (2022). 10.1029/2022GL097814 [DOI] [Google Scholar]
- 10.Geiger, R. et al. Detecting inertial effects with airborne matter-wave interferometry. Nat. Commun.2, 474 (2011). 10.1038/ncomms1479 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Bidel, Y. et al. Absolute marine gravimetry with matter-wave interferometry. Nat. Commun.9, 627 (2018). 10.1038/s41467-018-03040-2 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Bidel, Y. et al. Absolute airborne gravimetry with a cold atom sensor. J. Geod.94, 20 (2020). 10.1007/s00190-020-01350-2 [DOI] [Google Scholar]
- 13.Aguilera, D. N. et al. STE-QUEST–test of the universality of free fall using cold atom interferometry. Class. Quantum Gravity31, 115010 (2014). 10.1088/0264-9381/31/11/115010 [DOI] [Google Scholar]
- 14.El-Neaj, Y. A. et al. AEDGE: atomic experiment for dark matter and gravity exploration in space. EPJ Quantum Technol.7, 6 (2020). 10.1140/epjqt/s40507-020-0080-0 [DOI] [Google Scholar]
- 15.Lévèque, T. et al. Gravity field mapping using laser-coupled quantum accelerometers in space. J. Geod.95, 15 (2021). 10.1007/s00190-020-01462-9 [DOI] [Google Scholar]
- 16.Jekeli, C. Navigation error analysis of atom interferometer inertial sensor. J. Inst. Nav.52, 1–14 (2005). 10.1002/j.2161-4296.2005.tb01726.x [DOI] [Google Scholar]
- 17.Peters, A., Chung, K. Y. & Chu, S. High-precision gravity measurements using atom interferometry. Metrologia38, 25 (2001). 10.1088/0026-1394/38/1/4 [DOI] [Google Scholar]
- 18.Canuel, B. et al. Six-axis inertial sensor using cold-atom interferometry. Phys. Rev. Lett.97, 010402 (2006). 10.1103/PhysRevLett.97.010402 [DOI] [PubMed] [Google Scholar]
- 19.Gauguet, A., Canuel, B., Lévèque, T., Chaibi, W. & Landragin, A. Characterization and limits of a cold-atom Sagnac interferometer. Phys. Rev. A80, 063604 (2009). 10.1103/PhysRevA.80.063604 [DOI] [Google Scholar]
- 20.Müller, T. et al. A compact dual atom interferometer gyroscope based on laser-cooled rubidium. Eur. Phys. J. D53, 273–281 (2009). 10.1140/epjd/e2009-00139-0 [DOI] [Google Scholar]
- 21.Lan, S.-Y., Kuan, P.-C., Estey, B., Haslinger, P. & Müller, H. Influence of the coriolis force in atom interferometry. Phys. Rev. Lett.108, 090402 (2012). 10.1103/PhysRevLett.108.090402 [DOI] [PubMed] [Google Scholar]
- 22.Sugarbaker, A., Dickerson, S. M., Hogan, J. M., Johnson, D. M. S. & Kasevich, M. A. Enhanced atom interferometer readout through the application of phase shear. Phys. Rev. Lett.111, 113002 (2013). 10.1103/PhysRevLett.111.113002 [DOI] [PubMed] [Google Scholar]
- 23.Zhao, Y., Yue, X., Chen, F. & Huang, C. Extension of the rotation-rate measurement range with no sensitivity loss in a cold-atom gyroscope. Phys. Rev. A104, 013312 (2021). 10.1103/PhysRevA.104.013312 [DOI] [Google Scholar]
- 24.Zahzam, N. et al. Hybrid electrostatic-atomic accelerometer for future space gravity missions. Remote Sens.14, 3273 (2022). 10.3390/rs14143273 [DOI] [Google Scholar]
- 25.Templier, S. et al. Tracking the vector acceleration with a hybrid quantum accelerometer triad. Sci. Adv.8, eadd3854 (2022). 10.1126/sciadv.add3854 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Roura, A., Zeller, W. & Schleich, W. P. Overcoming loss of contrast in atom interferometry due to gravity gradients. New J. Phys.16, 123012 (2014). 10.1088/1367-2630/16/12/123012 [DOI] [Google Scholar]
- 27.Antoine, C. & Bordé, C. J. Exact phase shifts for atom interferometry. Phys. Lett. A306, 277–284 (2003). 10.1016/S0375-9601(02)01625-0 [DOI] [Google Scholar]
- 28.Beaufils, Q. et al. Rotation related systematic effects in a cold atom interferometer onboard a nadir pointing satellite. npj Microgravity9, 53 (2023). 10.1038/s41526-023-00297-w [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Alonso, I. et al. Cold atoms in space: community workshop summary and proposed road-map. EPJ Quantum Technol.9, 30 (2022). 10.1140/epjqt/s40507-022-00147-w [DOI] [Google Scholar]
- 30.Rakholia, A. V., McGuinness, H. J. & Biedermann, G. W. Dual-axis, high data-rate atom interferometer via cold ensemble exchange. Phys. Rev. Appl.2, 8 (2014). 10.1103/PhysRevApplied.2.054012 [DOI] [Google Scholar]
- 31.Hoth, G. W., Pelle, B., Riedl, S., Kitching, J. & Donley, E. A. Point source atom interferometry with a cloud of finite size. Appl. Phys. Lett.109, 071113 (2016). 10.1063/1.4961527 [DOI] [Google Scholar]
- 32.Lautier, J. et al. Hybridizing matter-wave and classical accelerometers. Appl. Phys. Lett.105, 144102 (2014). 10.1063/1.4897358 [DOI] [Google Scholar]
- 33.Ménoret, V. et al. Gravity measurements below 10−9 g with a transportable absolute quantum gravimeter. Sci. Rep.8, 12300 (2018). 10.1038/s41598-018-30608-1 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Overstreet, C., Asenbaum, P. & Kasevich, M. A. Physically significant phase shifts in matter-wave interferometry. Am. J. Phys.89, 324–332 (2021). 10.1119/10.0002638 [DOI] [Google Scholar]
- 35.Cheinet, P. et al. Measurement of the sensitivity function in a time-domain atomic interferometer. IEEE Trans. Instrum. Meas.57, 1141–1148 (2008). 10.1109/TIM.2007.915148 [DOI] [Google Scholar]
- 36.Struckmann, C. et al. Platform and environment requirements of a satellite quantum test of the weak equivalence principle at the 10−17 level. arXivhttps://arxiv.org/abs/2310.04212 (2023).
- 37.Xu, Y.-y et al. Measuring the effective height for atom gravimeters by applying a frequency jump to Raman lasers. Rev. Sci. Instrum.92, 063202 (2021). 10.1063/5.0047996 [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The raw data generated in this study have been deposited in the Zenodo database with the reference 11543715.



