Abstract
In this work, palladium nanoparticles (PdNPs)/p1,5-DAN/ carbon paste electrode (CPE) and p1,5-DAN/CPE sensors have been developed for determination of hydrogen peroxide. Both sensors showed a highly sensitive and selective electrochemical behaviour, which were derived from a large specific area of poly 1,5 DAN and super excellent electroconductibility of PdNPs. PdNPs/p1,5-DAN/CPE exhibited excellent performance over p1,5-DAN/CPE. Thus, it was used for detecting hydrogen peroxide (H2O2) with linear ranges of 0.1 to 250 µM and 0.2 to 300 µM as well as detection limits (S/N = 3) of 1.0 and 5.0 nM for square wave voltammetry (SWV) and cyclic voltammetry (C.V) techniques, respectively. The modified CPE has good reproducibility, adequate catalytic activity, simple synthesis and stability of peak response during H2O2 oxidation on long run that exceeds many probes. Both reproducibility and stability for H2O2 detection are attributable to the PdNPs immobilized on the surface of p1,5-DAN/CPE. The modified CPE was used for determining H2O2 in real specimens with good stability, sensitivity, and reproducibility.
Keywords: hydrogen peroxide, modified electrodes, palladium nanoparticles, sensors, square wave voltammetry
1. Introduction
Hydrogen peroxide (H2O2) is widely used in industrial and medical applications [1,2]. Biologically reactive oxygen species is produced from cell oxidases, which help the signal transduction of cells [3]. Excess use of H2O2 is associated with defects in cell growth, genetic carrier (DNA), and cytokines damage [4,5]. H2O2 can be determined by chemiluminescence [6], colorimetry [7], titrimetry [8], spectrophotometry [9] and fluorescence [10] techniques. However, these techniques are time-consuming, expensive, complex and suffer from interference with other analytes.
Electrochemical methods have important applications such as sample analysis as well as organic and inorganic synthesis [11]. These methods are attractive for biological and environmental analysis because they are cheap, simple, fast, sensitive and selective [12]. For example, electrochemical assays were used for H2O2 detection, with high sensitivity and selectivity [13]. H2O2 interferes with oxygen and its oxidation peak, which allows adequate detection rather than using the reduction peak [14]. The direct oxidation or reduction of H2O2 is inconvenient because of the high overvoltage and slow kinetics of a bare electrode [15]. Detectors, sensors and electrode syntheses depend mainly on carbon paste because of the wide voltage window, low price and low background intensity (current) [16].
The hollow polymer nanospheres allowed the dispersion of metal nanoparticles (NPs) [17]. The fabricated sensors of metal NPs have many advantages which gives such a response [18]. Palladium is a very important rare transition metal that has good catalytic activity and reported hetero-catalytic and electroanalytical behaviours [19]. The physical and chemical properties of palladium (Pd) NPs are similar to those of platinum NPs, but their price is lower. PdNPs are ideal building blocks for designing and altering nanoscale structures for specific sensing applications. They have many interesting properties such as electrocatalytic behaviour, high specific surface area, strong adsorption ability, high conductivity, improved electron transfer and reduced overpotential in electrochemical reactions [20–22]. Incorporating PdNPs in biosensors gave such high catalytic behaviour with good stability [23,24]. Electrochemical and some chemical methods have been used to incorporate PdNPs into a conducting polymer matrix [25–27]. Also, PdNPs could be dispersed in many other polymers [27,28]. H2O2 electrooxidation via PdNPs was reported [29–31]. The direct electrooxidation of the three isomers of dihydroxybenzene at lower potentials and lower detection limits was studied on PdNPs/poly1,5-diaminonaphthalene modified GC electrodes [32]. In addition, many electrochemical sensors, which were based on p1,5-DAN, were previously investigated [33–36].
Modified CPE has been applied as an electrochemical sensor for the analysis of various biologically important compounds [11,12,37–43] due to its low residual current, low cost, relative ease of electrode preparation and regeneration, and the porous surface. To the best of our knowledge, this is the first time to use PdNPs/p1,5-DAN on the surface of CPE for sensitive determination of H2O2. This approach is considered accessible and ecologically green for p1,5-DAN/CPE and PdNPs/p1,5-DAN/CPE. PdNPs/p1,5-DAN/CPE have a larger surface area, rapid mass transfer and excellent electron transfer capability compared to p1,5-DAN/CPE, imparting excellent electrocatalytic performance toward H2O2 sensing at 0.05 and −0.2 V using cyclic voltammetry (CV), and −0.12 V for square wave voltammetry (SWV) techniques.
A recent study has developed a non-enzymatic amperometric sensor by stabilizing gold (Au) NPs on a porous titanium dioxide (TiO2) nanotube (NTs) electrode (TiO2-NTs). The aggregation was prevented by entrapping AuNPs on TiO2 NTs. The sensor enhanced the electron transfer rate and the electrical conductivity, and generated a low detection limit of 104 nM [18]. Also, nickel oxide NPs modified multiwalled carbon nanotubes were prepared and supported on glassy carbon electrode for H2O2 sensing. The applied electrode showed good stability and reproducibility with LOD of 1.0 µM [44]. The modification of glassy carbon electrode with colloidal microcatalyst of PdNPs decorated on polyaniline coated carbon microspheres was applied for H2O2 sensing. This provides a large number of catalytic sites, high electrochemical surface area and excellent electrocatalytic activity toward H2O2 reduction with LOD of 0.7 µM [25].
2. Experimental
2.1. Instrumentations and reagents
A Voltalab Model PST006, equipped with Voltamaster4 software was used for the determination experiments [35]. The most traditionally used three-electrode cell of silver/silver chloride (Ag/AgCl) as the electrode, platinum wire (Pt) as the electrode, and CPE as the reference, auxiliary and working electrodes, respectively, was employed for all voltammetry experiments. The following chemicals were used, [1,5-Diaminonaphthalene (1,5-DAN) (97% Merck USA), graphite powder (Sigma Aldrich), NaOH (Pellets 99.8%, Merck USA), PdCl2 (59% Merck USA) and H2O2 (Adwic, El-Nasr pharmaceutical chemical, co, Egypt)]. Double distilled water was used to prepare all reagents. K4Fe(CN)6 (Sigma Aldrich), KCl (99.5% Sigma Aldrich), where NaCl, NaHCO3, Na2SO4 and CuCl2 (Adwic, El-Nasr pharmaceutical chemical, co, Egypt). Scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX) were provided by Nanotechnology Research Center, Kafr el-Sheikh University, Egypt, using JEOL USA, JSM IT-100.
2.2. Preparation of working electrode
The manual blending and mixing of graphite powder with paraffin oil ‘70 : 30 wt./wt.’ was accomplished using a mortar and pestle. Electrical contact was achieved using copper wire inside a glass tube with an internal radius of approximately 1.5 mm that enclosed the paste. After the bare electrode surface was smoothed on white paper, a smooth and shiny surface was observed. The preparation of p1,5-DAN/CPE from a well-mixed solution of 1.0 M HClO4 and 1.5 mM 1,5-DAN was employed using CV under the following conditions:15 cycles, potential range 0.0–0.8 V and at a scan rate of 0.02 V.s−1.The modified electrode was placed in a homogeneous mixture of 0.1 M HClO4 and 2.5 mM PdCl2 and analysed by CV for 25 cycles at a sweep rate ‘0.05 V.s−1’ between ‘−0.35 and 0.65 V' for ‘25 cycles’, as reported for PdNPs/p1,5-DAN/CPE [4]. This method has received widespread attention because it is simple, and it can ensure the high purity of sensor and the selective position of Pd on the surface [23].
3. Results and discussion
3.1. Physical characterization of the modified CPE
3.1.1. Scanning electron microscopy and energy dispersive X-ray spectroscopy
The response of a modified electrochemical electrode is related to its physical morphology. As shown in figure 1 a,b, the surface topographies of the modified electrode were analysed by SEM, which demonstrated significant differences in the surface structure of both p1,5-DAN/CPE and PdNPs/p1,5-DAN/CPE, respectively.
Figure 1.
SEM images of (a) p1,5-DAN/CPE and (b,c) PdNPs/p1,5-DAN/CPE, and (d) EDX histogram of PdNPs/p1,5-DAN/CPE.
SEM shows that the morphologies and textures of both layers were not similar (figure 1). The structure of p1,5-DAN (figure 1 a) shows whitish grey, spherical, amorphous open structure porous accumulations with a large lumpy shape [36,45]. Figure 1 b presents PdNPs deposited on p1,5-DAN/CPE, in which Pd particles appear as white light-grey spherical spots with a mean diameter of approximately 46 nm dispersed on the modified electrode surface.
These data show that PdNPs/p1,5-DAN/CPE is affected by the incorporation of PdNPs into the p1,5-DAN structure. This structure gives a high number of effective active sites that act as supporting sites for the deposition of PdNPs [46]. The conducting polymer increased active surface area and the catalytic activity. Figure 1 d shows that EDX identified the presence of PdNPs in the polymeric matrix where the PdNPs were dispersed in the p1,5-DAN polymeric matrix at 2.4% for PdNPs/p1,5-DAN/CPE.
3.2. Electrochemical characterization of the modified CPE
3.2.1. Determination of the electroactive surface area
PdNPs/p1,5-DAN/CPE showed a smaller peak voltage separation ‘ΔEp = 0.099 V, with a high redox intensity when tested in 1 × 10−6 mol.cm−3 [Fe(CN)6]−3/−4’ in CV, which was comparable to the bare CPE (figure 2 a). It exhibited better redox kinetics due to better current response, lower oxidation potential and smaller peak to peak separation and marked as quasi-reversible redox process and its redox parameters were enhanced sufficiently because of their high electric conductivity.
Figure 2.
(a) CV traces of 1 × 10−6 mol.cm−3 K4Fe(CN)6 in 0.1 M KCl [a- CPE, b- p1,5-DAN/CPE and c- PdNPs/p1,5-DAN/CPE] at a scan rate of 0.05 V/s and CV traces for 1 × 10−6 mol.cm−3 K4Fe(CN)6 in 0.1 M KCl for (b) bare CPE, (c) p1,5-DAN/CPE and (d) PdNPs/p1,5-DAN/CPE at sweep rates from 0.05 to 0.5 V/s. Inset, the relationship between Ip and v1/2.
Equation (3.1) shows the calculation of the active surface area of the modified electrode using the Randles–Sevcik equation [47]:
| 3.1 |
where C is the K4Fe(CN)6 concentration (mol.cm−3), D is the diffusion coefficient (cm2.s−1), A is the surface area of the electrode (cm2), v is the scan rate (Vs−1), n is the number of transferred electrons and Ip is the peak intensity. The square root of the scan rate and the anodic peak intensity are represented by the following equations: Ipa = 2.006 + 36.32 v1/2, bare CPE; Ipa = 19.14 + 154.76 v1/2, p1,5-DAN/CPE; Ipa = 37.31 + 458.3 v1/2, PdNPs/p1,5-DAN/CPE. The electroactive surface areas for PdNPs/p1,5-DAN/CPE, p1,5-DAN/CPE, and bare CPE were 0.6, 0.2, and 0.05 cm2, respectively. These results suggest an increase in the active surface area of the modified electrode by 12-fold compared to the bare CPE. The voltage peak difference was approximately 0.192 V where formal potential E0 was 0.14 V for bare CPE, as shown in figure 2 b. After the CPE modification with p1,5-DAN, there is a small decrease of ΔEp∼0.16 V with E0 of 0.124 V (figure 2 c), whereas the ΔEp decreased to approximately 0.099 V with E0 of 0.25 V after the deposition of palladium nanoparticles (PdNPs), as shown in figure 2 d [48]. ΔEp is inversely proportional to the electron transfer rate [49]. The bare CPE showed less electron transfer at the modified electrode surface. Accordingly, PdNPs/p1,5-DAN/CPE demonstrated the highest electron transfer rates from the lowest ΔEp ∼0.099 V (figure 2 d). Overall, depositing PdNPs on p1,5-DAN/CPE improved the conductivity and electrochemical properties of the catalyst.
3.3. Effect of the electrolyte concentration on the redox behaviour of H2O2
The strength of the basic solution influences the H2O2 decomposition rate, where the decomposition rate in a LiOH solution is 4–5 times higher than in distilled water, pH (7.0), as reported by Haines et al. [50]. Navarro et al. [51] investigated the optimal H2O2 decomposition in NaOH solutions with pH = (11.5–11.7). H2O2 oxidation in more alkaline solutions was enhanced at lower voltages, as reported by Katsounaros [52]. This study examined the effect of the electrolyte concentration using sodium hydroxide solutions.
Figure 3 a presents the CV traces of 24 µM H2O2 decomposition on the p1,5-DAN/CPE electrode in various NaOH concentrations (0.02–0.5 M) with pH ranges from 12.3 to 13.7. The oxidation current, Ipa, increased from 76 to 118 µA, and the peak voltage difference (ΔEp) decreased from 0.751 to 0.544 V. Figure 3 b shows the CV trace of 19.5 µM H2O2 decomposition on the p1,5-DAN/CPE electrode in various NaOH concentrations (0.02–0.5 M). The oxidation current, Ipa, increased from 55 to 359 µA, and the peak voltage difference (ΔEp) decreased from 0.433 to 0.25 V. By comparing these curves, the most appropriate electrolyte for this study was 0.5 M NaOH of pH (13.7) because of the high redox current, low redox potential, and low peak-to-peak separation.
Figure 3.
CV traces of A-24 µM H2O2 at p1,5-DAN/CPE, and B-19.5 µM H2O2 at PdNPs/p1,5-DAN/CPE in various NaOH concentrations of (a) 0.5, (b) 0.3, (c) 0.1, (d) 0.05 and (e) 0.02 M, sweep rate 0.05 V/s.
3.4. Effect of the pH of NaOH on the redox behaviour of H2O2
The pH of the supporting electrolyte influenced the value of oxidation and reduction peak voltage of H2O2, suggesting the involvement of protons in the redox reaction [53]. According to figure 4 a,c, the anodic and cathodic peak currents for redox reaction of H2O2 at the two electrodes, one of palladium and the other of palladium absence, increased with increasing pH from (12.3 to 13.7) and the maximum current observed at pH (13.7).
Figure 4.
Dependence of pH on (a) current, (b) voltage of p1,5-DAN/CPE in NaOH containing 24 µM H2O2 and dependence of pH on (c) current, (d) voltage of PdNPs/p1,5-DAN/CPE in NaOH containing 19.5 µM H2O2.
Figure 4 b,d showed that the anodic and cathodic peak potentials presented a dependence on pH throughout the studied range (12.3–13.7), with shifting of anodic and cathodic potential to lower energy. Therefore, pH (13.7) was determined as the optimal pH value for the electrolyte [54].
3.5. Effect of the scan rate
PdNPs/p1,5-DAN/CPE could catalyze the H2O2 redox reaction at lower potentials with sufficiently high currents. Figure 5 shows the CV trace of 4.8 µM H2O2 with various sweep rates from 0.025–0.50 Vs−1 at PdNPs/p1,5-DAN/CPE.
Figure 5.
CV traces of 4.8 µM H2O2 in 0.5 M NaOH with various sweep rates from ‘0.025 to 0.5 V.s−1’ at PdNPs/p1,5-DAN/CPE.
The redox currents increased with increasing scan rate from 0.025 to 0.1 Vs−1. The scan rate (v) and peak current of H2O2 showed a linear from 0.025 to 0.1 Vs−1(figure 6 a) with Ipa (µA) = 49.19 + 0.335 v (mVs−1), where Ipc (µA) = −193.8–2.68 v (mVs−1) and represented by the following equation (equation (3.2)).
| 3.2 |
where A is the geometric surface area (cm2), n is the number of transferred electrons, v is the sweep rate (Vs−1), Г is the surface coverage (mole/cm2), F is the Faraday constant (96 484 C.mol−1), T is the absolute room temperature (298.15 K), R is the gas constant (8.314 J.mol−1.K−1). The surface coverage for the modified electrode was 1.59 × 10−7 for oxidation where 1.24 × 10−6 mole cm−2 for H2O2 reduction [55].
Figure 6.
Kinetic relationships at PdNPs/p1,5-DAN/CPE for (a) dependence of the peak intensity I pa and scan rate v, (b) plot of I p versus v1/2, (c) plot of log I pa, versus log v, and (d) plot of E p versus log v.
The square root of the scan rate from 0.1–0.5 Vs−1 and the anodic and cathodic pulse current showed a linear relationship with increasing the scan rate. Hence, the adsorption-controlled process changed to a diffusion-controlled process [32]. Thus, the process was reported as diffusion controlled. Figure 6 b presents the linear XY graph between the square root of the scan rate and the H2O2 peaks intensity with Ipa (µA) = −8.006 + 9.44 v1/2 (mVs−1) and Ipc (µA) = −25.43–44.2 v1/2 (mVs−1). By applying the Randless equation (equation (3.1)), the diffusion coefficient of H2O2 at PdNPs/p1,5-DAN/CPE was 1.06 × 10−5 cm s−1 for oxidation where 4.96 × 10−5 cm s−1 for reduction [47], which was recently reported [56].
By plotting the logarithm of the scan rate versus the logarithm of the current intensity, the H2O2 redox process at PdNPs/p1,5-DAN/CPE was determined to be a diffusion-controlled process (figure 6 c). The slope was approximately 0.48, indicating that the reaction is diffusion-controlled [57].
A graph of the logarithm of the scan rate, log v and peak voltage (E p) for the H2O2 redox process at PdNPs/p1,5-DAN/CPE was linear at a high scan rate, as shown in figure 6 d. The cathodic voltages shifted to the negative direction, whereas the anodic voltages shifted to the positive direction by the gradual increase in scan rate.
| 3.3 |
| 3.4 |
| 3.5 |
where α is the charge transfer coefficient and its value could be determined mathematically using equations (3.3), (3.4) and (3.5) and founded 0.6. The rate constant (k s) calculated using the Laviron equation was 0.22 cm.s−1 [55].
3.6. Effect of the amplitude on the redox behaviour of H2O2
The pulse amplitude is a parameter that strongly affects the peak current in square wave voltammetry affecting the sensitivity of the peak. Larger amplitudes have offered a better peak current, but as amplitudes become larger, the background current increases, the peak appears broader and shifts from its proper location it. Thus, if inappropriate amplitudes are used, it can lead to inaccurate results [58].
Figure 7 represents SWV of 19.5 µM H2O2 in 0.5 M NaOH with changing amplitude from (a = 0.02, b = 0.05 to c = 0.07 V) at (a) p1,5-DAN/CPE and (b) PdNPs/p1,5-DAN/CPE. We found that the peak current of H2O2 increased with increasing pulse amplitude from 0.02 to 0.07 V. When the pulse amplitude was higher than 0.05 V, the oxidation peak was wider and broader [33].
Figure 7.
SWV of 19.5 µM H2O2 in 0.5 M NaOH with different amplitudes (a = 0.02, b = 0.05 and c = 0.07 V) at (a) p1,5-DAN/CPE and (b) PdNPs/p1,5-DAN/CPE, scan rate of 0.05 V.s−1, duration of 0.1 s and pulse of 0.05 V.
3.7. Electrochemical behaviour of H2O2
3.7.1. Cyclic voltammetry behaviour
Figure 8 shows the CV response of H2O2, representing a typical CV trace of 78.3 µM H2O2 in 0.5 M NaOH at (a) PdNPs/p1,5-DAN/CPE and (b) p1,5-DAN/CPE, at a sweep rate of 0.05 Vs−1. By modification of CPE by only p1,5-DAN/CPE, an anodic peak appeared at E pa = 0.222 V, I pa = 415 µA and a cathodic peak of E pc = −0.322 V, I pc = 420 µA. In the case of adding a second layer of palladium nanoparticles onto the polymer film, a well-characterized and enhanced anodic peak was observed with E pa = 0.05 V, I pa = 466 µA, and a cathodic peak of E pc = −0.2 V, I pc = −705 µA. The peak-to-peak separation (ΔE) and formal potential were 0.25 and 0.125 V for PdNPs/p1,5-DAN/CPE compared to 0.544 and 0.272 V for p1,5-DAN/CPE. The PdNPs impart very high electrocatalytic activity for H2O2 catalytic oxidation and reduction at low redox potentials compared to p1,5-DAN/CPE. The PdNPs/p1,5-DAN/CPE improved the CV sensitivity for H2O2 because of the ease of electron transfer in catalytic reactions [59].
Figure 8.
CV traces of ‘78.3 µM H2O2’ in ‘0.5 M NaOH’ recorded at (a) PdNPs/p1,5-DAN/CPE and (b) p1,5-DAN/CPE, sweep rate 0.05 V/s.
3.7.2. Behaviour of square wave voltammetry ‘SWV’
The recognition of the background current and low detection limit were examined by SWV [33]. This technique was employed for H2O2 oxidation at PdNPs/p1,5-DAN/CPE because of its low contribution to the background current and high current sensitivity.
Figure 9 presents the SWV trace of PdNPs/p1,5-DAN/CPE and p1,5-DAN/CPE in 0.5 M NaOH containing 3.2 µM H2O2, the oxidation peaks with anodic currents were at −0.12 and 0.115 V for 40.6 and 19.5 µA, respectively. From the anodic peak potential and current, PdNPs/p1,5-DAN/CPE can improve H2O2 detection corresponding to the CV results.
Figure 9.
SWV of (a) absence of 3.2 µM H2O2 in 0.5 M NaOH at PdNPs/p1,5-DAN/CPE, (b) 3.2 µM H2O2 in 0.5 M NaOH at p1,5-DAN/CPE, and (c) at PdNPs/p1,5-DAN/CPE, at a scan rate of 0.05 V.s−1, duration of 0.1 s, amplitude of 0.05 V and pulse of 0.05 V.
3.8. Determination of H2O2
3.8.1. Cyclic voltammetry determination
CV demonstrated the best determination of H2O2 at PdNPs/p1,5-DAN/CPE. Figure 10 a shows the CV traces for various H2O2 concentrations in 0.5 M NaOH at p1,5-DAN/CPE, and its inset shows a linear relationship for the redox concentrations and their currents. The linear regression equation for anodic oxidation was Ipa (µA) = 61.1 + 3.39 C (µM) with a correlation coefficient of 0.99, where Ipc (µA) = −271.3−1.06 C (µM) for cathodic reduction. The lower detection (LOD) and lower quantification (LOQ) limits for H2O2 oxidation by CV were 0.3 and 0.99 µM and for its reduction were 0.4 and 1.32 µM.
Figure 10.
CV traces of H2O2 in 0.5 M NaOH at (a) p1,5-DAN/CPE from 4.9 to 274 µM and (b) PdNPs/p1,5-DAN/CPE from 9.7 to 78.3 µM, scan rate of 0.05 V.s−1.
Figure 10 b presents the CV traces for the H2O2 concentrations in 0.5 M NaOH at PdNPs/p1,5-DAN/CPE. The inset showed the linear relationship between the redox concentrations and their currents. The linear regression equation for anodic oxidation was I pa (µA) = −5.9 + 7.5 C (µM) with a correlation coefficient of 0.99 where I pc (µA) = −54.8−15.4 C (µM) for cathodic reduction. The limit of detection (LOD) and limit of quantification (LOQ) for H2O2 oxidation by CV were 5.0 and 16.6 nM, respectively, whereas they were 4.0 and 13.3 nM for its reduction, respectively. The LOD and LOQ values were calculated using equations (3.6) and (3.7).
| 3.6 |
and
| 3.7 |
where is the blank standard deviation and m is the linear's slope [16].
These results suggest that the PdNPs/p1,5-DAN/CPE can effectively mediate electron transfer between the electrode and H2O2, showing clear catalytic activity toward electrochemical redox determination. This approach can be applied to the determination of a lower H2O2 concentration.
The electrochemical H2O2 reduction mechanism was reported previously [60,61] as equations (3.8)–(3.10).
| 3.8 |
| 3.9 |
| 3.10 |
The polymer film (1,5-DAN) has many imino groups (─NH) which have constructed hydrogen bonds leading to a decrease in the hydroxyl bond energy through an O─H …. NH bond [32]. Moreover, PdNPs have created more O─H …. PdNPs bonds which helped in the electron transfer [62].
This electron transfer has gained by adsorbed H2O2 on the electrocatalyst surface which produces (OH)ads and OH─ as in equation (3.8). Subsequently, another electron is received by (OH)ads resulting in H2O formation. In all processes, the reaction rate is influenced primarily by two factors : (1) H2O2 adsorption at the electrocatalyst surface and (2) electron transfer from the electrocatalyst to the (OH)ads. Thus, the electrocatalyst must enhance the adsorption and electron transfer to establish the electrocatalytic reduction successfully [63].
The sensitivity determination of p1,5-DAN/CPE and PdNPs/p1,5-DAN/CPE were 12 500 µAmM−1 cm−2 and 16 950 µAmM−1 cm−2, respectively, according to equation (3.11) [64].
| 3.11 |
where m is the linear slope and A the electrode active area.
3.8.2. Square wave voltammetry of H2O2
Figure 11 a shows the SWV for p1,5-DAN/CPE in different concentrations of H2O2 from 0.45 to 19 µM. Figure 11 b represents the SWV of PdNPs/p1,5-DAN/CPE in different concentrations of H2O2 from 4.8 to 20.5 µM. The inset of figure 11 a,b shows linear graphs of the peak versus H2O2 concentrations. The p1,5-DAN/CPE's coefficient (R 2) was 0.99 with I pa (µA) = 15.5 + 0.77 C of H2O2, where 0.99 with I pa (µA) = −276.3 + 27.07 C for PdNPs/p1,5-DAN/CPE. The LOD, LOQ and sensitivity were 0.038 µM, 0.126 µM and 3850 µAmM−1 cm−2, respectively, at p1,5-DAN/CPE. However, the values for PdNPs/p1,5-DAN/CPE were 1.0 nM, 3.32 nM and 45 000 µAmM−1 cm−2, respectively. The Pd in the hollow polymer matrix was responsible for the excellent performance, because it increases the surface area and provides many active sites for the catalytic reactions that in turn improves the sensitivity, selectivity and conductivity of the sensor [32].
Figure 11.
SWV of H2O2 in 0.5 M NaOH (a) at p1,5-DAN/CPE from 0.45 to 19 µM and (b) at PdNPs/p1,5-DAN/CPE from 4.8 to 20.5 µM, scan rate of 0.05 V.s−1, duration of 0.1 s amplitude of 0.05 V and pulse of 0.05 V.
Table 1 lists the LODs for H2O2 determination at both p1,5-DAN/CPE and PdNPs/p1,5-DAN/CPE compared with previously investigated modified electrodes. From table 1, in comparison with previously reported CPE, PdNPs/p1,5-DAN/CPE could determine H2O2 at a good lower concentration limit with low redox potentials. Also, the electrochemical determination of H2O2 at PdNPs/poly 1,5-DAN/CPE has not been previously performed, ensuring the novelty of our work.
Table 1.
Electrochemical determination of H2O2 at different modified electrodes. Abbreviations: (AP-Ni-MOF Ni+2-based metal-organic framework) (PNMA [SDS]the polymer of N-methylaniline which was synthesized in the presence of sodium dodecyl sulfate) (SCE saturated calomel electrode) (PVA polyvinyl alcohol) ((PEDOT:PSS poly 3,4-ethylenedioxythiophene: polystyrene sulfonate) (HRP horseradish peroxidase) (PGN porous graphene) (TiO2 titanium dioxide) (Ag@PPy-C silver decorated polypyrrole-carbon black) (CS/GOP crosslinked chitosan and polyaniline grafted grapheme oxide composite) (NiO, nickel oxide nanoparticles- CNT, modified multiwalled carbon nanotubes- PEI, polyethyleneimine) [(Au(pc) polycrystalline gold electrode] (sub-CYST sub-monolayer coverage of cysteine).
| electrode | electrocatalytic mediator | electrocatalytic effect (mV) | LOD (µM) | LDR (µM) | references |
|---|---|---|---|---|---|
| CPE | p-1,5-DAN | Epa = 222 | 0.3 (CV) | 0.6–283 | this work |
| Epc = −322 | 0.4 (CV) | 0.6–283 | |||
| Epa = 115 | 0.038 (SWV) | 0.2–200 | |||
| CPE | PdNPs/p-1,5-DAN | Epa = 50 | 0.005 (CV) | 0.2–300 | this work |
| Epc = −200 | 0.004 (CV) | 0.2–300 | |||
| Epa = −120 | 0.001(SWV) | 0.1–250 | |||
| CPE | AP-Ni-MOF | Epc = −250 | 0.9 | 4–60 000 | [65] |
| CPE | PNMA(SDS)/Co | Epa = 400 | CV =18 | 30–12 000 | [66] |
| DPV = 3 | 5–48 | ||||
| SWV = 0.9 | 1–12 | ||||
| GCE | PtPd/MWCNTs | Epa = 250 | 1.2 | 2.5–125 | [67] |
| GCE | gold nanoparticle-silica sol-gel | Epc = −500 (versus SCE) | 0.003 | 2.5–45 | [68] |
| GCE | PVA/MWCNTs/PtNPs | Epc = 0 | 0.7 | 2–3,800 | [69] |
| GCE | AgNPs/MWCNT/rGO/ | Epc = −350 | 0.9 | 0.1–100 | [70] |
| ITO | polyaniline grafted MWNT | Epc = −300 (versus SCE) | 0.001 | 0.01–0.2 | [71] |
| GCE | Prussian blue | Epa = 50 | 0.01 | 0.01–10 000 | [72] |
| GC rotating electrode | cobalt oxide nanoparticles | Epa = 750 | 0.0004 | 0.004–0.08 | [73] |
| Pt | PVA/AgNPs | Epc = −553 (versus SCE) | 1.0 | 1.2–1,000 | [74] |
| GCE | MnO2 Nanosheets | Epc = −600 | 0.0005 | 0.025–454 | [75] |
| GCE | Cs micelle/PEDOT: PSS/HRP/Nafion | Epc = −238 | 0.00003 | 0.0001–10 | [76] |
| GCE | HRP/PGN | Epc = −700 (versus SCE) | 0.00002 | 2.77–835 | [77] |
| TiO2 NPs | AuNPs | Epc = −350 | 0.104 | 1–198 | [18] |
| GCE | Ag@PPy-C/TiO2 NCs | Epa = 250 | 0.23 | 5–57 | [78] |
| GCE | CS/GOP | Epc = −470 | 17.3 | 0.5–200 | [63] |
| GCE | CNT-PEI@NiO | Epa = 600 | 1.0 | 4–800 | [44] |
| Au(pc) | sub-CYST | Epa = −100 | 0.8 | 1–3,000 | [79] |
3.9. Real samples analysis
This study examined H2O2 in various spiked water sources (canned, underground, tap water) using the very good response electrode PdNPs/p1,5-DAN/CPE. No permissions were required prior to conducting field studies. A 10 ml cell of a real sample of 0.5 M NaOH was used for the spiked sample 0.1 mM H2O2 / 0.5 M NaOH using the standard addition method, while SWV was applied using the PdNPs/p1,5-DAN/CPE. Table 2 lists the average recoveries of all specimens repeated four times. Data analysis showed that the fabricated modified electrode could determine different H2O2 concentrations in real samples. The good recovery and response, easy preparation, and low cost give a chance for the PdNPs/p1,5-DAN/CPE for its use in industry as a fast detector of H2O2.
Table 2.
Determination of H2O2 in real water samples at PdNPs/p1,5-DAN/CPE.
| samples | added (µM) | found recovery (µM) | (%) | nRSD (%) | |
|---|---|---|---|---|---|
| tap | 1 | 4.62 | 4.53 | 98.1 | 0.46 |
| 2 | 4.66 | 4.66 | 100 | 0.19 | |
| 3 | 4.68 | 4.5 | 96.2 | 0.31 | |
| underground | 1 | 4.8 | 4.62 | 96.3 | 0.45 |
| 2 | 2.38 | 2.51 | 105.5 | 0.85 | |
| 3 | 3.63 | 3.43 | 94.4 | 1.09 | |
| canned | 1 | 4.51 | 4.18 | 92.6 | 0.61 |
| 2 | 2.15 | 2.15 | 100 | 0.97 | |
| 3 | 4.49 | 4.23 | 94.1 | 0.51 |
n RSD% calculated from four measurements.
3.10. Interference study
The selectivity of PdNPs/p1,5-DAN/CPE toward H2O2 determination was examined by determining the effects of potentially interfering species, including 4.97 µM urea, 4.97 µM ascorbic acid, 24.8 mM Na+, 24.8 mM Cl−, 24.8 mM K+, 24.8 mM , 9.9 mM , 4.9 mM Cu+2, on PdNPs/p1,5-DAN/CPE containing 4.97 µM H2O2. Table 3 confirms the absence of interference with H2O2 peak current, only a signal change ≤5%. Thus PdNPs/p1,5-DAN/CPE has good selectivity toward H2O2 determination.
Table 3.
Interfering species effects on H2O2 determination.
| sample number | samples | % signal |
|---|---|---|
| 1 | urea | 0.94 |
| 2 | ascorbic acid | 0.47 |
| 3 | Na+ | 2.35 |
| 4 | Cl− | 1.1 |
| 5 | K+ | 1.72 |
| 6 | HCO3 | 3.4 |
| 7 | SO4 | 2.5 |
| 8 | Cu+2 | 1.72 |
3.11. Stability and reproducibility of the PdNPs/p1,5-DAN/CPE
The stability, reversibility and reproducibility of PdNPs/p1,5-DAN/CPE are important factors for practical applications [80]. Figure 12 presents the CV traces of 4.8 µM H2O2 in 0.5 M NaOH for 30 successive cycles. The antifouling surface of the electrode was indicated by stable redox voltage and peak intensity. In addition to the intra-day precisions, the convenient tools for checking the electrode confirmed its reproducibility. The precision of the assay was tested by examining the sensor behaviour in one determined solution four times. The good precision of the assay was highlighted by the low RSD value of 0.62%. Ten different PdNPs/p1,5-DAN/CPE were prepared for the evaluation of reproducibility, five for intra-day and five for inter-day measurement. Each prepared electrode was used to measure the current intensity response of 4.8 µM H2O2 in 0.5 M NaOH. For the five intra-day fabricated electrodes the RSD of the five current intensities was 0.62% and 0.85% for the five inter-day prepared electrodes.
Figure 12.
CV trace of 4.8 µM H2O2 in 0.5 M NaOH at PdNPs/p1,5-DAN/CPE for 30 cycles, scan rate 0.025 V.s−1.
4. Conclusion
In this study, the double character of DAN (a hollow film) and PdNPs improved the electrochemical redox response toward H2O2 via increasing the effective surface area and electron transfer. The PdNPs/p1,5-DAN/CPE has become a promising sensor to determine H2O2 in real samples, environmental samples, and in enzymeless catalyzed reactions due to its advantages of high sensitivity, reproducibility, good stability and anti-interference ability against many interferents. The assay was simple and inexpensive for H2O2 determination with a lower detection limit and good precision.
Acknowledgements
The authors wish to thank the Alexander von Humboldt Foundation for the scientific donation of some electrochemical equipment.
Ethics
No permissions were required prior to conducting field studies.
Data accessibility
Source data were submitted to dryad through linkage https://doi.org/10.5061/dryad.3tx95x6nz [81].
Declaration of AI use
We have not used AI-assisted technologies in creating this article.
Authors' contributions
Z.K.: writing—review and editing; M.F.A.O.: writing—original draft; A.A.H.: resources, supervision; M.A.: resources, supervision.
All authors gave final approval for publication and agreed to be held accountable for the work performed therein.
Conflict of interest declaration
We have no competing interests.
Funding
This research received no particular grant from any funding agency in the public, private or not-for-profit sectors.
Funding
We received no funding for this study.
References
- 1. Uzuncar S, Kac H, Ak M. 2023. Electro-templating of prussian blue nanoparticles in PEDOT:PSS and soluble silkworm protein for hydrogen peroxide sensing. Talanta. 252 , 123 841-123 854. ( 10.1016/j.talanta.2022.123841) [DOI] [PubMed] [Google Scholar]
- 2. Mounesh, Manikanta P, Reddy KRV, Selvaraj M, Vidyasagar CC, Nagaraja BM. 2023. Novel decorated aluminium(iii) phthalocyanine complex with the application of MWCNTs on electrodes: electrochemical non-enzymatic oxidation and reduction of glucose and hydrogen peroxide. RSC Adv. 13 , 20 723-20 736. ( 10.1039/D3RA02617E) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3. Wu L, Li Z, Yao Y. 2023. Hydrogen peroxide preconditioning is of dual role in cardiac ischemia/reperfusion. Eur. J. Pharmacol. 947 , 175 684-175 693. ( 10.1016/j.ejphar.2023.175684) [DOI] [PubMed] [Google Scholar]
- 4. Habibi B, Mohammadyari S. 2015. Facile synthesis of Pd nanoparticles on nano carbon supports and their application as an electrocatalyst for oxidation of ethanol in alkaline media: The effect of support. Int. J. Hydrogen Energy. 40 , 10 833-10 846. ( 10.1016/j.ijhydene.2015.07.021) [DOI] [Google Scholar]
- 5. Shao M, et al. 2023. From liver fibrosis to hepatocarcinogenesis: Role of excessive liver H2O2 and targeting nanotherapeutics. Bioact Mater. 23 , 187-205. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6. Park JS, Kim S-K, Choi C-H, Park JP, Park K. 2023. Novel chemiluminescent nanosystem for highly sensitive detection of hydrogen peroxide in vivo. Sens. Actuators, B. 393 , 134 261-134 269. ( 10.1016/j.snb.2023.134261) [DOI] [Google Scholar]
- 7. Kurbah SD, Syiemlieh I, Lal RA. 2018. Colorimetric detection of hydrogen peroxide by dioxido-vanadium(V) complex containing hydrazone ligand: synthesis and crystal structure. R. Soc. Open Sci. 5 , 171 471-171 478. ( 10.1098/rsos.171471) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8. Ghohestani E, Tashkhourian J, Hemmateenejad B. 2023. Colorimetric determination of peroxide value in vegetable oils using a paper based analytical device. Food Chem. 403 , 134 345-134 351. ( 10.1016/j.foodchem.2022.134345) [DOI] [PubMed] [Google Scholar]
- 9. Joshi PP, Merchant SA, Wang Y, Schmidtke DW. 2005. Amperometric biosensors based on redox polymer-carbon nanotube-enzyme composites. Anal. Chem. 77 , 3183-3188. ( 10.1021/ac0484169) [DOI] [PubMed] [Google Scholar]
- 10. Chen X, et al. 2023. Smartphone-assisted colorimetric and near-infrared ratiometric fluorescent sensor for on-spot detection of H2O2 in food samples. Chem. Eng. J. 472 , 144 900-144 906. ( 10.1016/j.cej.2023.144900) [DOI] [Google Scholar]
- 11. Raoof J-B, Ojani R, Beitollahi H. 2007. Electrocatalytic Determination of Ascorbic Acid at Chemically Modified Carbon Paste Electrode with 2, 7-bis (Ferrocenyl ethynyl) Fluoren-9-one. Int. J. Electrochem. Sci. 2 , 534-548. ( 10.1016/S1452-3981(23)17094-5) [DOI] [Google Scholar]
- 12. Mazloum-Ardakani M, Beitollahi H, Ganjipour B, Naeimi H. 2010. Novel Carbon Nanotube Paste Electrode for Simultaneous Determination of Norepinephrine, Uric Acid and D-Penicillamine. Int. J. Electrochem. Sci. 5 , 531-546. ( 10.1016/S1452-3981(23)15304-1) [DOI] [Google Scholar]
- 13. Xing L, Zhang W, Fu L, Lorenzo JM, Hao Y. 2022. Fabrication and application of electrochemical sensor for analyzing hydrogen peroxide in food system and biological samples. Food Chem. 385 , 132 555-132 565. ( 10.1016/j.foodchem.2022.132555) [DOI] [PubMed] [Google Scholar]
- 14. Karyakin AA, Puganova EA, Bolshakov IA, Karyakina EE. 2007. Electrochemical sensor with record performance characteristics. Angew. Chem. Int. Ed. Engl. 46 , 7678-7680. ( 10.1002/anie.200700341) [DOI] [PubMed] [Google Scholar]
- 15. Deng Z, Zhao L, Zhou H, Xu X, Zheng W. 2022. Recent advances in electrochemical analysis of hydrogen peroxide towards in vivo detection. Process Biochem. 115 , 57-69. ( 10.1016/j.procbio.2022.01.025) [DOI] [Google Scholar]
- 16. Santos AM, Wong A, Feitosa MHA, Silva LP, Fatibello-Filho O, Moraes FC. 2022. Using Carbon Paste Electrode Modified with Graphene and Nanodiamond for the Determination of Nimesulide in Biologic and Environmental Samples. Electroanalysis. 34 , 1441-1449. ( 10.1002/elan.202100578) [DOI] [Google Scholar]
- 17. Usman F, Ghazali KH, Fen YW, Meriaudeau F, Jose R. 2023. Biosensing through surface enhanced Raman spectroscopy: A review on the role of plasmonic nanoparticle-polymer composites. Eur. Polym. J. 195 , 112 250-112 280. ( 10.1016/j.eurpolymj.2023.112250) [DOI] [Google Scholar]
- 18. Kader MA, Azmi NS, Kafi AKM, Hossain MS, Jose R, Goh KW. 2023. Ultrasensitive Nonenzymatic Real-Time Hydrogen Peroxide Monitoring Using Gold Nanoparticle-Decorated Titanium Dioxide Nanotube Electrodes. Biosensors (Basel). 13 , 1-17. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19. Kim M-Y, Park H, Lee J-Y, Park DJ, Lee J-Y, Myung NV, Lee KH. 2022. Hierarchically palladium nanoparticles embedded polyethyleneimine–reduced graphene oxide aerogel (RGA–PEI–Pd) porous electrodes for electrochemical detection of bisphenol a and H2O2 . Chem. Eng. J. 431 , 134 250-134 261. ( 10.1016/j.cej.2021.134250) [DOI] [Google Scholar]
- 20. Wu B, Kuang Y, Zhang X, Chen J. 2011. Noble metal nanoparticles/carbon nanotubes nanohybrids: Synthesis and applications. Nano Today. 6 , 75-90. ( 10.1016/j.nantod.2010.12.008) [DOI] [Google Scholar]
- 21. Akyıldırım O, Kardaş F, Beytur M, Yüksek H, Atar N, Yola ML. 2017. Palladium nanoparticles functionalized graphene quantum dots with molecularly imprinted polymer for electrochemical analysis of citrinin. J. Mol. Liq. 243 , 677-681. ( 10.1016/j.molliq.2017.08.085) [DOI] [Google Scholar]
- 22. Liu Z, Xue Q, Guo Y. 2017. Sensitive electrochemical detection of rutin and isoquercitrin based on SH-beta-cyclodextrin functionalized graphene-palladium nanoparticles. Biosens. Bioelectron. 89 , 444-452. ( 10.1016/j.bios.2016.04.056) [DOI] [PubMed] [Google Scholar]
- 23. Ning L, Liu Y, Ma J, Fan X, Zhang G, Zhang F, Peng W, Li Y. 2017. Synthesis of Palladium, ZnFe2O4 Functionalized Reduced Graphene Oxide Nanocomposites as H2O2 Detector. Industrial Eng. Chem. Res. 56 , 4327-4333. ( 10.1021/acs.iecr.6b04964) [DOI] [Google Scholar]
- 24. Hamidi H, Haghighi B. 2016. Fabrication of a sensitive amperometric sensor for NADH and H2O2 using palladium nanoparticles-multiwalled carbon nanotube nanohybrid. Mater. Sci. Eng. C Mater. Biol. Appl. 62 , 423-428. ( 10.1016/j.msec.2016.01.058) [DOI] [PubMed] [Google Scholar]
- 25. Promsuwan K, Soleh A, Saisahas K, Saichanapan J, Thiangchanya A, Phonchai A, Limbut W. 2021. Micro-colloidal catalyst of palladium nanoparticles on polyaniline-coated carbon microspheres for a non-enzymatic hydrogen peroxide sensor. Microchem. J. 171 , 106 785-106 794. ( 10.1016/j.microc.2021.106785) [DOI] [Google Scholar]
- 26. Lamiri L, Belgherbi O, Dehchar C, Laidoudi S, Tounsi A, Nessark B, Habelhames F, Hamam A, Gourari B. 2020. Performance of polybithiophene-palladium particles modified electrode for non-enzymatic glucose detection. Synth. Met. 266 , 116 437-116 444. ( 10.1016/j.synthmet.2020.116437) [DOI] [Google Scholar]
- 27. Cherian AR, Benny L, George A, Sirimahachai U, Varghese A, Hegde G. 2022. Electro fabrication of molecularly imprinted sensor based on Pd nanoparticles decorated poly-(3 thiophene acetic acid) for progesterone detection. Electrochim. Acta. 408 , 139 963-139 976. ( 10.1016/j.electacta.2022.139963) [DOI] [Google Scholar]
- 28. Hui Y, Yang D, Wei L, Pu M, Mao Y, Chen X, Wang B. 2024. Rapid and label-free electrochemical aptasensor based on a palladium nanoparticles/titanium carbide/polyethyleneimine functionalized nitrogen-doped carbon nanotubes composite for amplified detection of streptomycin. Food Chem. 432 , 137 271-137 280. ( 10.1016/j.foodchem.2023.137271) [DOI] [PubMed] [Google Scholar]
- 29. Sophia J, Muralidharan G. 2015. Polyvinylpyrrolidone stabilized palladium nanospheres as simple and novel electrochemical sensor for amperometric hydrogen peroxide detection. J. Electroanal. Chem. 739 , 115-121. ( 10.1016/j.jelechem.2014.12.021) [DOI] [Google Scholar]
- 30. Zhang WJ, Bai L, Lu LM, Chen Z. 2012. A novel and simple approach for synthesis of palladium nanoparticles on carbon nanotubes for sensitive hydrogen peroxide detection. Colloids Surf. B Biointerfaces. 97 , 145-149. ( 10.1016/j.colsurfb.2012.04.021) [DOI] [PubMed] [Google Scholar]
- 31. Nie G, Lu X, Lei J, Yang L, Bian X, Tong Y, Wang C. 2013. Sacrificial template-assisted fabrication of palladium hollow nanocubes and their application in electrochemical detection toward hydrogen peroxide. Electrochim. Acta. 99 , 145-151. ( 10.1016/j.electacta.2013.03.066) [DOI] [Google Scholar]
- 32. Khalifa Z, Hassan K, Abo Oura MF, Hathoot A, Azzem MA. 2020. Individual and Simultaneous Voltammetric Determination of Ultra-Trace Environmental Contaminant Dihydroxybenzene Isomers Based on a Composite Electrode Sandwich-like Structure. ACS Omega. 5 , 18 950-18 957. ( 10.1021/acsomega.0c02228) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33. Essa WA, Beltagi AM, Hathoot AA, Azzem MA. 2020. A Sensitive Voltammetric Sensor for Improved Simultaneous Determination of Moxifloxacin Hydrochloride and Paracetamol. J. Electrochem. Soc. 167 , 167 509-167 520. ( 10.1149/1945-7111/abcc34) [DOI] [Google Scholar]
- 34. Shatla AS, Hassan KM, Abd-El-Latif AA, Hathoot AA, Baltruschat H, Abdel-Azzem M. 2019. Poly 1,5 diaminonaphthalene supported Pt, Pd, Pt/Pd and Pd/Pt nanoparticles for direct formic acid oxidation. J. Electroanal. Chem. 833 , 231-241. ( 10.1016/j.jelechem.2018.11.005) [DOI] [Google Scholar]
- 35. Hassan KM, Hathoot AA, Abo Oura MF, Azzem MA. 2018. Simultaneous and selective electrochemical determination of hydroquinone, catechol and resorcinol at poly(1,5-diaminonaphthalene)/glassy carbon-modified electrode in different media. RSC Adv. 8 , 6346-6355. ( 10.1039/C7RA13665J) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36. Hathoot AA, Hassan KM, Essa WA, Abdel-Azzem M. 2017. Simultaneous determination of ascorbic acid, uric acid and dopamine at modified electrode based on hybrid nickel hexacyanoferrate/poly(1,5-diaminonaphthalene). J. Iran. Chem. Soc. 14 , 1789-1799. ( 10.1007/s13738-017-1119-8) [DOI] [Google Scholar]
- 37. Raoof J-B, OjaniJ R, Beltollahi H, Hosseinzadeh R. 2006. Electrocatalytic Oxidation and Highly Selective Voltammetric Determination of L-Cysteine at the Surface of a 1- [4-(Ferrocenyl ethynyl)phenyl]-1-ethanone Modified Carbon Paste Electrode. Anal. Sci. 22 , 1213-1220. ( 10.2116/analsci.22.1213) [DOI] [PubMed] [Google Scholar]
- 38. Mazloum Ardakani M, Taleat Z, Beitollahi H, Salavati-Niasari M, Mirjalili BBF, Taghavinia N. 2008. Electrocatalytic oxidation and nanomolar determination of guanine at the surface of a molybdenum (VI) complex–TiO2 nanoparticle modified carbon paste electrode. J. Electroanal. Chem. 624 , 73-78. ( 10.1016/j.jelechem.2008.07.027) [DOI] [Google Scholar]
- 39. Kazemipour M, Ansari M, Mohammadi A, Beitollahi H, Ahmadi R. 2009. Use of adsorptive square-wave anodic stripping voltammetry at carbon paste electrode for the determination of amlodipine besylate in pharmaceutical preparations. J. Anal. Chem. 64 , 65-70. ( 10.1134/S1061934809010134) [DOI] [Google Scholar]
- 40. Mazloum-Ardakani M, Beitollahi H, Mohseni MA, Benvidi A, Naeimi H, Nejati-Barzoki M, Taghavinia N. 2010. Simultaneous determination of epinephrine and acetaminophen concentrations using a novel carbon paste electrode prepared with 2,2'- [1,2 butanediylbis(nitriloethylidyne)]-bis-hydroquinone and TiO2 nanoparticles. Colloids Surf. B Biointerfaces. 76 , 82-87. ( 10.1016/j.colsurfb.2009.10.019) [DOI] [PubMed] [Google Scholar]
- 41. Beitollahi H, Sheikhshoaie I. 2012. Electrochemical Behavior of Carbon Nanotube/Mn(III) Salen Doped Carbon Paste Electrode and Its Application for Sensitive Determination of N-acetylcysteine in the Presence of Folic Acid. Int. J. Electrochem. Sci. 7 , 7684-7697. ( 10.1016/S1452-3981(23)15815-9) [DOI] [Google Scholar]
- 42. Mazloum-Ardakani M, Taleat Z, Khoshroo A, Beitollahi H, Dehghani H. 2012. Electrocatalytic oxidation and voltammetric determination of levodopa in the presence of carbidopa at the surface of a nanostructure based electrochemical sensor. Biosens. Bioelectron. 35 , 75-81. ( 10.1016/j.bios.2012.02.014) [DOI] [PubMed] [Google Scholar]
- 43. Zhou Q, Zhai HY, Pan YF. 2018. Voltammetric determination of phenylephrine hydrochloride using a multi-walled carbon nanotube-modified carbon paste electrode. R. Soc. Open Sci. 5 , 181 264-181 270. ( 10.1098/rsos.181264) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44. Fernández I, Carinelli S, González-Mora JL, Villalonga R, Salazar-Carballo PA. 2022. Nickel oxide Nanoparticles/Carbon Nanotubes Nanocomposite for Nonenzymatic Determination of Hydrogen Peroxide. Electroanalysis. 35 , 1-9. [Google Scholar]
- 45. Benvidi A, Jahanbani S, Akbari A, Zare HR. 2015. Simultaneous determination of hydrazine and hydroxylamine on a magnetic bar carbon paste electrode modified with reduced graphene oxide/Fe3O4 nanoparticles and a heterogeneous mediator. J. Electroanal. Chem. 758 , 68-89. ( 10.1016/j.jelechem.2015.10.008) [DOI] [Google Scholar]
- 46. Hathoot AA, Hassan KM, Ali AG, Shatla AS, Baltruschat H, Abdel-Azzem M. 2019. Mono and dual hetero-structured M@poly-1,2 diaminoanthraquinone (M=Pt, Pd and Pt-Pd) catalysts for the electrooxidation of small organic fuels in alkaline medium. RSC Adv. 9 , 1849-1858. ( 10.1039/C8RA09342C) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47. Rajendrachari S, Basavegowda N, Vinaykumar R, Narsimhachary D, Somu P, Lee M-J. 2023. Electrocatalytic determination of methyl orange dye using mechanically alloyed novel metallic glass modified carbon paste electrode by cyclic voltammetry. Inorg. Chem. Commun. 155 , 111 010-111 018. ( 10.1016/j.inoche.2023.111010) [DOI] [Google Scholar]
- 48. Qu F, Sun H, Zhang S, You J, Yang M. 2012. Electrochemical sensing platform based on palladium modified ceria nanoparticles. Electrochim. Acta. 61 , 173-178. ( 10.1016/j.electacta.2011.11.113) [DOI] [Google Scholar]
- 49. Jiang YJ, Hui S, Tian S, Chen Z, Chai Y, Jiang LP, Zhang JR, Zhu JJ. 2022. Enhanced transmembrane electron transfer in Shewanella oneidensis MR-1 using gold nanoparticles for high-performance microbial fuel cells. Nanoscale Adv. 5 , 124-132. ( 10.1039/D2NA00638C) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 50. Wu L, Shoesmith DW. 2014. An Electrochemical Study of H2O2 Oxidation and Decomposition on Simulated Nuclear Fuel (SIMFUEL). Electrochim. Acta. 137 , 83-90. ( 10.1016/j.electacta.2014.06.002) [DOI] [Google Scholar]
- 51. Navarro JA, de la Rosa MA, Roncel M, de la Rosa F. 1984. Carbon Dioxide-mediated Decomposition of Hydrogen Peroxide in Alkaline Solutions. J. Chem. Soc., Faraday Trans. 1 , 249-253. [Google Scholar]
- 52. Katsounaros I, Mayrhofer KJ. 2012. The influence of non-covalent interactions on the hydrogen peroxide electrochemistry on platinum in alkaline electrolytes. Chem Commun (Camb) 48 , 6660-6662. ( 10.1039/c2cc32652c) [DOI] [PubMed] [Google Scholar]
- 53. Deroco PB, Fatibello-Filho O, Arduini F, Moscone D. 2019. Effect of Different Carbon Blacks on the Simultaneous Electroanalysis of Drugs as Water Contaminants Based on Screen-printed Sensors. Electroanalysis. 31 , 2145-2154. ( 10.1002/elan.201900042) [DOI] [Google Scholar]
- 54. Lopa NS, Rahman MM, Ahmed F, Chandra Sutradhar S, Ryu T, Kim W. 2018. A base-stable metal-organic framework for sensitive and non-enzymatic electrochemical detection of hydrogen peroxide. Electrochim. Acta. 274 , 49-56. ( 10.1016/j.electacta.2018.03.148) [DOI] [Google Scholar]
- 55. Prabhu P, Suresh Babu R, Sriman Narayanan S. 2011. Amperometric determination of l-dopa by nickel hexacyanoferrate film modified gold nanoparticle graphite composite electrode. Sens. Actuators, B. 156 , 606-614. ( 10.1016/j.snb.2011.02.006) [DOI] [Google Scholar]
- 56. Yin D, Bo X, Liu J, Guo L. 2018. A novel enzyme-free glucose and H2O2 sensor based on 3D graphene aerogels decorated with Ni3N nanoparticles. Anal. Chim. Acta. 1038 , 11-20. ( 10.1016/j.aca.2018.06.086) [DOI] [PubMed] [Google Scholar]
- 57. Mashhadizadeh MH, Yousefi T, Nozad Golikand A. 2012. A nickel hexacyanoferrate and poly(1-naphthol) hybrid film modified electrode used in the selective electroanalysis of dopamine. Electrochim. Acta. 59 , 321-328. ( 10.1016/j.electacta.2011.10.070) [DOI] [Google Scholar]
- 58. Guziejewski D. 2018. Square wave Amplitude Effect in Cathodic and Anodic Stripping Square-wave Voltammetry. Electroanalysis. 31 , 231-238. ( 10.1002/elan.201800425) [DOI] [Google Scholar]
- 59. Baghayeri M, Amiri A, Razghandi H. 2019. Employment of Pd nanoparticles at the structure of poly aminohippuric acid as a nanocomposite for hydrogen peroxide detection. J. Electroanal. Chem. 832 , 142-151. ( 10.1016/j.jelechem.2018.10.063) [DOI] [Google Scholar]
- 60. Kubendhiran S, Thirumalraj B, Chen SM, Karuppiah C. 2018. Electrochemical co-preparation of cobalt sulfide/reduced graphene oxide composite for electrocatalytic activity and determination of H2O2 in biological samples. J. Colloid Interface Sci. 509 , 153-162. ( 10.1016/j.jcis.2017.08.087) [DOI] [PubMed] [Google Scholar]
- 61. Katsounaros I, Schneider WB, Meier JC, Benedikt U, Biedermann PU, Auer AA, Mayrhofer KJ. 2012. Hydrogen peroxide electrochemistry on platinum: towards understanding the oxygen reduction reaction mechanism. Phys. Chem. Chem. Phys. 14 , 7384-7391. ( 10.1039/c2cp40616k) [DOI] [PubMed] [Google Scholar]
- 62. Besson M, Gallezot P. 2000. Selective oxidation of alcohols and aldehydes on metal catalyst. Catal. Today 57 , 127-141. ( 10.1016/S0920-5861(99)00315-6) [DOI] [Google Scholar]
- 63. Nasir A, Khalid S, Mazare A, Yasin T. 2023. Non-enzymatic hydrogen peroxide detection on a novel nanohybrid composite of chitosan and grafted graphene oxide. Mater. Res. Bull. 167 , 112 427-112 435. ( 10.1016/j.materresbull.2023.112427) [DOI] [Google Scholar]
- 64. Ahmad K, Mohammad A, Mobin SM. 2017. Hydrothermally grown α-MnO2 nanorods as highly efficient low cost counter-electrode material for dye-sensitized solar cells and electrochemical sensing applications. Electrochim. Acta. 252 , 549-557. ( 10.1016/j.electacta.2017.09.010) [DOI] [Google Scholar]
- 65. Sherino B, Mohamad S, Abdul Halim SN, Abdul Manan NS. 2018. Electrochemical detection of hydrogen peroxide on a new microporous Ni–metal organic framework material-carbon paste electrode. Sens. Actuators, B. 254 , 1148-1156. ( 10.1016/j.snb.2017.08.002) [DOI] [Google Scholar]
- 66. Ojani R, Raoof J-B, Norouzi B. 2010. Carbon paste electrode modified by cobalt ions dispersed into poly (N-methylaniline) preparing in the presence of SDS: application in electrocatalytic oxidation of hydrogen peroxide. J. Solid State Electrochem. 14 , 621-631. ( 10.1007/s10008-009-0824-3) [DOI] [Google Scholar]
- 67. Chen KJ, Chandrasekara Pillai K, Rick J, Pan CJ, Wang SH, Liu CC, Hwang BJ. 2012. Bimetallic PtM (M=Pd, Ir) nanoparticle decorated multi-walled carbon nanotube enzyme-free, mediator-less amperometric sensor for H2O2 . Biosens. Bioelectron. 33 , 120-127. ( 10.1016/j.bios.2011.12.037) [DOI] [PubMed] [Google Scholar]
- 68. Maduraiveeran G, Ramaraj R. 2007. Gold nanoparticles embedded in silica sol–gel matrix as an amperometric sensor for hydrogen peroxide. J. Electroanal. Chem. 608 , 52-58. ( 10.1016/j.jelechem.2007.05.009) [DOI] [Google Scholar]
- 69. Fang Y, Zhang D, Qin X, Miao Z, Takahashi S, Anzai J-i, Chen Q. 2012. A non-enzymatic hydrogen peroxide sensor based on poly(vinyl alcohol)–multiwalled carbon nanotubes–platinum nanoparticles hybrids modified glassy carbon electrode. Electrochim. Acta. 70 , 266-271. ( 10.1016/j.electacta.2012.03.105) [DOI] [Google Scholar]
- 70. Lorestani F, Shahnavaz Z, Mn P, Alias Y, Manan NSA. 2015. One-step hydrothermal green synthesis of silver nanoparticle-carbon nanotube reduced-graphene oxide composite and its application as hydrogen peroxide sensor. Sens. Actuators, B. 208 , 389-398. ( 10.1016/j.snb.2014.11.074) [DOI] [Google Scholar]
- 71. Santhosh P, Manesh KM, Gopalan A, Lee KP. 2006. Fabrication of a new polyaniline grafted multi-wall carbon nanotube modified electrode and its application for electrochemical detection of hydrogen peroxide. Anal. Chim. Acta. 575 , 32-38. ( 10.1016/j.aca.2006.05.075) [DOI] [PubMed] [Google Scholar]
- 72. Karyakin AA, Puganova EA, Budashov IA, Kurochkin IN, Karyakina EE, Levchenko VA, Matveyenko VN, Varfolomeyev SD. 2004. Prussian blue based nanoelectrode arrays for H2O2 detection. Anal. Chem. 76 , 474-480. ( 10.1021/ac034859l) [DOI] [PubMed] [Google Scholar]
- 73. Salimi A, Hallaj R, Soltanian S, Mamkhezri H. 2007. Nanomolar detection of hydrogen peroxide on glassy carbon electrode modified with electrodeposited cobalt oxide nanoparticles. Anal. Chim. Acta. 594 , 24-31. ( 10.1016/j.aca.2007.05.010) [DOI] [PubMed] [Google Scholar]
- 74. Guascito MR, Filippo E, Malitesta C, Manno D, Serra A, Turco A. 2008. A new amperometric nanostructured sensor for the analytical determination of hydrogen peroxide. Biosens. Bioelectron. 24 , 1063-1069. ( 10.1016/j.bios.2008.07.048) [DOI] [PubMed] [Google Scholar]
- 75. Shu Y, Xu J, Chen J, Xu Q, Xiao X, Jin D, Pang H, Hu X. 2017. Ultrasensitive electrochemical detection of H2O2 in living cells based on ultrathin MnO2 nanosheets. Sens. Actuators, B. 252 , 72-78. ( 10.1016/j.snb.2017.05.124) [DOI] [Google Scholar]
- 76. Zhang R, Xu X, Fan X, Yang R, Wu T, Zhang C. 2018. Application of conducting micelles self-assembled from commercial poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) and chitosan for electrochemical biosensor. Colloid. Polym. Sci. 296 , 495-502. ( 10.1007/s00396-018-4270-6) [DOI] [Google Scholar]
- 77. Liu Y, Liu X, Guo Z, Hu Z, Xue Z, Lu X. 2017. Horseradish peroxidase supported on porous graphene as a novel sensing platform for detection of hydrogen peroxide in living cells sensitively. Biosens. Bioelectron. 87 , 101-107. ( 10.1016/j.bios.2016.08.015) [DOI] [PubMed] [Google Scholar]
- 78. Faisal M, Alam MM, Asiri AM, Alsaiari M, Saad Alruwais R, Jalalah M, Madkhali O, Rahman MM, Harraz FA. 2023. Detection of hydrogen peroxide with low-dimensional silver nanoparticle-decorated PPy-C/TiO2 nanocomposites by electrochemical approach. J. Electroanal. Chem. 928 , 117 030-117 040. ( 10.1016/j.jelechem.2022.117030) [DOI] [Google Scholar]
- 79. Dutta A, Hasan MM, Miah MR, Nagao Y, Hasnat MA. 2021. Efficient sensing of hydrogen peroxide via electrocatalytic oxidation reactions using polycrystalline Au electrode modified with controlled thiol group immobilization. Electrochim. Acta. 395 , 139 217-139 228. ( 10.1016/j.electacta.2021.139217) [DOI] [Google Scholar]
- 80. Gupta VK, Mergu N, Kumawat LK, Singh AK. 2015. A reversible fluorescence ‘off-on-off’ sensor for sequential detection of aluminum and acetate/fluoride ions. Talanta. 144 , 80-89. ( 10.1016/j.talanta.2015.05.053) [DOI] [PubMed] [Google Scholar]
- 81. Khalifa Z, Abo Oura MF, Hathoot A, Azzem MA. 2024. Voltammetric determination of hydrogen peroxide at decorated palladium nanoparticles/poly 1,5-diaminonaphthalene modified carbon-paste electrode. Dryad. ( 10.5061/dryad.3tx95x6nz) [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Source data were submitted to dryad through linkage https://doi.org/10.5061/dryad.3tx95x6nz [81].












