Abstract
Microorganisms are widely used for the industrial production of various valuable products, such as pharmaceuticals, food and beverages, biofuels, enzymes, amino acids, vaccines, etc. Research is constantly carried out to improve their properties, mainly to increase their productivity and efficiency and reduce the cost of the processes. The selection of microorganisms with improved qualities takes a lot of time and resources (both human and material); therefore, this process itself needs optimization. In the last two decades, microfluidics technology appeared in bioengineering, which allows for manipulating small particles (from tens of microns to nanometre scale) in the flow of liquid in microchannels. The technology is based on small-volume objects (microdroplets from nano to femtolitres), which are manipulated using a microchip. The chip is made of an optically transparent inert to liquid medium material and contains a series of channels of small size (<1 mm) of certain geometry. Based on the physical and chemical properties of microparticles (like size, weight, optical density, dielectric constant, etc.), they are separated using microsensors. The idea of accelerated selection of microorganisms is the application of microfluidic technologies to separate mutants with improved qualities after mutagenesis. This article discusses the possible application and practical implementation of microfluidic separation of mutants, including yeasts like Yarrowia lipolytica and Phaffia rhodozyma after chemical mutagenesis will be discussed.
Keywords: microfluidics, microorganisms, mutagenesis, microdroplet, selection
Graphical Abstract
Graphical Abstract.
Introduction
Yeast has many diverse applications, including the food industry, such as the production of beer and wine; the medical industry, such as food supplement production or the production of recombinant biopharmaceuticals; the biofuel industry, such as bioethanol and biobutanol production; and finally, the single-cell protein industry for the production of dietary protein and animal feed [1]. While yeast has been used for centuries, the selection and improvement of strains are still needed as the desired characteristics and requirements are constantly changing, along with the industry. Desired characteristics include productivity, range of substrate that can be utilized, substrate consumption efficiency, etc. Another strain improvement route is modifying metabolism and new substance production, such as human insulin. Saccharomyces cerevisiae is one of the most used strains in biotechnology, commonly used for beer, wine, and bread production, while strains such as Scheffersomyces stipitis, Yarrowia lipolytica, Kluyveromyces lactis, Dekkera bruxellensis, and Phaffia rhodozyma fall in nonconventional category [2].
Phaffia rhodozyma is a basidiomycetous yeast well-known for producing the carotenoid pigment astaxanthin. This pigment has many applications due to its bioactive and pigmentation properties. It is used as an additive in food and beverages, feed, nutraceuticals, pharmaceuticals, and cosmetics products [3–6]. Astaxanthin is an antioxidant used as a health supplement for humans [7]. Phaffia rhodozyma can produce substantial amounts of astaxanthin from industrial by-products, which is an attractive and feasible approach to meet the market needs of astaxanthin [8]. The oleaginous, strictly aerobic yeast Y. lipolytica represents a potential microbial cell factory for the recombinant production of various valuable products. The yeasts’ potential as a synthesizer of several high-value food ingredients, such as organic acids, aromas, and emulsifiers from a range of diverse substrates, from ethanol to olive oil waste, is of interest in a biorefinery context. Yarrowia lipolytica synthesizes a wide range of functional and bioactive compounds that can act as active ingredients in functional beverages [9–12].
Even though both microorganism species have beneficial industrial characteristics, they still need to be improved as their commercialization efforts require further development. To improve commercial suitability, mutants are often created and screened to find an enhancement, for example, in secondary metabolite production, biomass yield, growth speed, or stress tolerance. Mutants can be created using various methods through mutagenesis, but unfortunately, organism mutation rates are low. Thus, the selection requires many lines grown in parallel. Generally, this process requires a lot of human resources and time.
A technology called microfluidics is increasingly used in bioengineering. It allows to manipulate small-sized particles from tens of microns to nanometre scale such as droplets and cells. Based on the physical and chemical differences of particles, including size, weight, optical density, dielectric constant, etc., they can be recognized and separated from each other. Consequently, this technique is often used in screening mutants as it allows us to evaluate each mutant separately, which is not possible in flask experiments where the population of mutants is evaluated.
One of the first microdroplet cell encapsulations was published in 1945 by Joshua Lederberg [13]. From this first laborious, time-consuming, and low-throughput demonstration, microfluidic technology has evolved tremendously. It is constantly improving, and new prospects have appeared: DNA amplification, enzymatic assays, biochemical assays, nanoparticle research, medical diagnosis, and fundamental research [14–17]. Microfluidic technologies go far beyond the biotechnology boundaries [18–20]. However, this article will touch on a small field of microdroplet applications and focus on droplet-based microfluidic technologies for cell cultivation and sorting.
The goal of this review is to research possible concept solutions for the mutant selection of P. rhodozyma and Y. lipolytica using microdroplet technology by analysing already existing data from publications. We will try to find and discuss factors that may help to reveal previously not published solutions to create a stable, cost-effective, suitable setup for cell cultivation, test and sort mutants with high growth density and productivity. Also, the required hardware and software will be partially mentioned in this review. We will refer to publications outlining the basic principles of technology and the latest progress in the field when discussing a specific topic. This review is also intended as a guide for possibilities and considerations that must be assessed if one plans to use microdroplet technology for the selection of yeast mutants.
Microorganisms, mutagenesis, and microfluidics in the accelerated selection of mutants
Both P. rhodozyma and Y. lipolytica have been extensively researched for their industrially valuable qualities, and both have been improved via mutagenesis and mutant screening [21–26]. Random mutagenesis is one of the most widely used methods for improving wild-type strains for industrial application as it does not depend on the host genetics, allowing it to be used for a variety of microorganisms. Another benefit is the obtained mutant library with high genetic diversity and, finally, the process does not involve direct genetic, modification which simplifies the certification process [27]. Considerations outlined in this article can also be appropriated for other species of yeast and other groups of microorganisms, but to narrow down the possibilities and to derive more specific conclusions for the selected technological solutions, we will focus on these two yeast species.
Mutants can be created using various methods, such as random mutagenesis using chemical mutagens, UV-radiation treatment, or biotechnological means, including gene editing. Chemical- and UV-mediated mutagenesis methods are one of the oldest and most widely used for their ease of use and low cost [28–32], while atmospheric and room temperature plasma-intermediated mutagenesis is one of the newest developments in the field [27]. To narrow down the focus of the article in further descriptions, we will refer to a well-known and still widely utilized ethyl methane sulfonate (EMS) chemical mutagenesis [33–35].
Screening for improved mutants is a time-consuming task if rudimentary methods are used: for example, growing microorganisms in flasks or microwell plates (Fig. 1) [36]. While methods work well for testing and comparing strains with each other, higher throughput is always desirable. For increased throughput, one of the more promising techniques is the cultivation of mutants in microdroplets. Each microdroplet becomes a separate microreactor for a cell. The benefits of using this technique are increased mutant screening throughput and homogeneous genotype per tested sample. Low growth, but high-yield mutant identification and selection is possible [37].
Figure 1.
Basic strategies for microorganism cultivation and selection (adapted from [36]). (This figure and all the following have been created using Microsoft Paint and Google Drawings diagramming software).
The first method of Fig. 1, serial transfer cultivation, is simple and cost-effective and has produced yeast strains that have increased stress tolerance, such as high temperature and pH, improved product yields, and increased substrate consumption. The method applies constant or escalating environmental pressure and selects mutants for higher specific growth rates. While the method is cost-effective, it requires manual labor, which takes time or robotization, which is a high-cost investment. Another strategy is the use of batch reactors instead of vessels, such as test tubes and flasks, which add benefits of automation and data from sensors such as CO2, pH, oxygen levels, etc. Chemostat cultivation instead of selection for mutants with high specific growth rate uses selection for high substrate affinity, as biomass with metabolites are continuously removed. Similarly, auxostats and turbidostats do not require empty-filled cycles, but instead of selecting on higher substrate affinity, again, selection is based on a specific growth rate as biomass is added back into a bioreactor. Lastly, the dynamic selection pressure cultivation method can obtain mutants with many phenotypical changes simultaneously as each selective pressure is applied in a cyclic approach.
The scheme of the entire process of mutant selection using microdroplets is presented in Fig. 2. Water-based media with cell suspension after mutagenesis is encapsulated into droplets, forming an emulsion. Later, droplets with cells inside are incubated (mutant multiplication). Mutagenesis and, for example, possible directed evolution and incubation processes for different microorganisms in this article will not be further discussed. However, we will touch on the stability of emulsions and peculiarities of microdroplet generation as both are connected. It is worth noting that incubation could be performed in a microfluidic chip (MFC) or outside it. Microdroplets must be reinjected into the chip after incubation for selecting droplets with desired cell properties. This requires the detection of droplets and sorting them from the array. Most probably, both of those processes will occur on one device shortly after the other. And microscopical observation for controlling each step of the selection process will be necessary.
Figure 2.
Generalized scheme of the selection of yeast mutants.
Some important things that must be considered in the case of microdroplet technology should be noted. The emulsion must be preferably monodispersed instead of polydisperse. Monodisperse droplets of the same size provide the same growing conditions for encapsulated cells, while polydisperse do not. The required droplet size depends on microorganisms’ size and required incubation time [37]. As soon as cells consume substances from water-based feeding media, the droplet size must be large enough that the changes in concentration will not affect growth. Compatibility of feeding media with base liquid is also important: some compounds from the inner volume of the droplet may diffuse into outer media. Base media may affect the cells’ viability too. Fulfilling these sets of requirements can be challenging, especially in the case of Y. lipolytica, as this strain can excrete extracellular lipase and emulsifying agents, which might react with the outer phase [38]. The next microorganism-related aspect is incubation time, which can be from 8 h for fast-growing microorganisms like bacteria [39] to 7 days for slow-growing microorganisms, like algae [40]. With the increase of incubation time and temperature, emulsion stability decreases. Long incubation time can cause oxygenation problems as Y. lipolytica and P. rhodozyma are aerobic microorganisms. Consequently, one of the best solutions is the use of media with high oxygen permeability [41] or use constant mixing and oxygen supply [42]. However, mixing is not widely utilized because it can create strong shear forces and may destabilize the emulsion. Droplet volume can change during incubation due to microorganism metabolism and some other factors, such as diffusion [43]. This may also affect the emulsion stability during incubation. The reduction of volume can increase the risk of stress associated with high cell-density cultures, such as oxidative stress and changes in glutathione metabolism [44].
Both microdroplet generation rate and cell encapsulation precision have to be as high as possible. On the one hand, we must increase the total number of cells due to low mutation efficiency. However, large numbers or high concentrations of cells may cause difficulties. The first relates to encapsulation: distribution of cells inside droplets may vary from 0 to several cells per droplet. First, droplets must be correctly distributed: one cell per droplet is the optimal condition for further interpretation of the experiment. The other one relates to the generation, detection, and separation rates. The process rates at each experiment step affect the final selection time. Simple calculations show that reaching the desired number of sorted droplets can take tens of hours. Process rates are limited by pressure, such as flow velocities and the speed of detection/sorting devices. Nowadays, a significant increase in throughput from the first published microdroplet generation with 102 droplets per experiment to the current average throughput of 102–103 droplets/s and even reaching 104 droplets/s generation has been achieved.
Finally, both the detection and sorting methods of microdroplets must be sensitive and fast enough for mutant selection. Currently, those techniques utilize electric fields, acoustic waves, magnetic fields, laser heating, etc. [45].
Though microfluidic technology has been advancing at a high pace, there are still prominent hindrances. Chip design and manufacturing are still expensive and not easily available in comparison to 96-well plates. Expenses add up, considering that micropumps, flow-microcontrollers, and specific miniaturized devices for the detection and separation of microdroplets are also required. Finally, the optimization process can be difficult and require a lot of refinement before studies begin [46]. Nevertheless, technology is promising, and one may try to find ways to overcome drawbacks.
Designing of microfluidic system
Deciding if the microdroplet system will work for the project requirements is challenging as the microdroplet system has many interlinked factors and changing one factor will impact the entire system. Here we will discuss correlations between several factors to better understand and design the entire microfluidic system.
Microdroplet generation and cell encapsulation
As it was mentioned earlier, the idea of emulsion formation is well-known and quite simple—mixing two liquid phases that are insoluble in each other, one of which is continuous, and the other serves as a dispersion medium containing cells (see Fig. 3). The process of droplet generation could be characterized by desired droplet sizes, their variability, and a generation rate.
Figure 3.
General idea of emulsion formation.
Fluidic flow is established with the help of one or several micropumps or pressure controllers and with a device for controlling fluids as well as for the detection and separation of droplets, shortly called a MFC. As soon as the flow is not constant, variability of droplets’ sizes appears. Nowadays, pressure-controlled pumps are most frequently used as they have the smallest fluid pulsation in comparison to syringes and peristaltic pumps [47]. This allows us to obtain droplets with the smallest differences between them, generating monodisperse emulsion to provide unified growing conditions. Those differences could be characterized by the coefficient of variability (CoV) of droplets’ sizes (Equation (1)):
| (1) |
where σ is the standard deviation of droplet sizes, and μ is the average size of droplets.
The generation rate depends on droplet size and is affected by total flow velocity and properties of liquids. On the one hand, the flow velocity is limited by the total hydrodynamic resistance of the microfluidic systems, including supplying tubing, which has a pressure limit that both the controller and chip can hold. On the other hand, increasing flow velocities will change the flow from laminar to turbulent until the moment when droplet generation fails. Finally, droplet dimension depends on the flow ratio between used liquids, their properties such as viscosity, materials’ surface characteristics, and channel geometry of MFC [48]. The relationships between the above-mentioned parameters are also shown in Yao et al. [49]. Chip design has an extremely wide variety of options and the final configuration depends on many factors. In this section, some of them and their relation to the full process will be discussed.
Geometry and design of microchips for droplet generation
As shown, for example, in [48], the size of microdroplets depends on the microchannel dimensions and flow rates. The size of the droplets increases with the increase in the size of the microchannel but decreases with the increase in the flow rate of the continuous phase.
Nowadays, the methods of controlling the process of droplet generation or fluids’ flows at the moment of formation of droplets could be classified as passive and active [50]. A review of passive approaches focuses on the characteristics and mechanisms of droplet formation modes occurring in microfluidic channels of specific geometry [50]. Some typical microdroplet passive generation designs [51] are shown in Fig. 4: flow-focusing, T-junction, co-flow, and multichannel emulsification configurations, etc. Active approaches cover state-of-the-art techniques employing external fields. Acoustic [52, 53], electrical [54], mechanical [55], and thermal [56] forces can be locally applied to tune droplet dimensions and production rates.
Figure 4.
Typical microfluidic geometries for creating microdroplets: (A) flow-focusing; (B) T-junction; (C) coaxial junction; (D) formation of multilayered emulsion; (E) multichannel emulsification process (images adapted from [51]); (F) ray-drop technology (image adapted from [57]).
Methods like flow-focusing or T-junction are simpler for controlling droplet sizes. The multichannel method can have the highest productivity when considerable number of droplets is needed, but also has difficulties with adjusting flows—the smallest differences between channel walls or flow instabilities can cause greater in comparison to the single-channel method variability of droplet sizes. Also, it requires controllers with high-pressure limits.
Those basic structures can be supplemented by additional channels to create more complex emulsion (see Fig. 5A) [58] or encapsulation of cells using alginate gelation (Fig. 5B) [59].
Figure 5.
Formation of complex emulsions (A) (adapted from [58]) and capsulation of droplets (B) (image adapted from [59]): (A) scheme reveals the importance of hydrophobicity (hydrophilicity) of channels during the stable formation of o/w/o or w/o/w emulsions (see also [60]); (B) alginate with calcium complexes is injected in flow-focusing junction that contains oil and acid, which starts gelation reaction. Formed droplets are injected in the second flow-focusing junction containing PFO, which destabilizes the emulsion. Microgels are then transferred from the oil to the water phase.
Chip material
Nowadays, there are many materials available for the creation of microfluidic devices, starting with silicon-based chips [61], chips based on glass, ceramic materials and metals [62–65], polymers [66–69], hydrogels [70–72], and composite materials [73–75]. The choice of the chip material can be determined by the desired type of emulsion [51, 76]. The hydrophilicity or hydrophobicity of the chip channels should be considered for a stable generation process: for water-in-oil (w/o) droplets, the channels must be hydrophobic (see Fig. 5A). For example, in the case of glass that is a hydrophilic chemical modification must be applied to make channels walls hydrophobic. The subsequent methods of detecting and separating microdroplets must also be considered: optical transparency, absorption at some specific wavelength range, or the need to make channels in the submicron scale. One can refer to references [77] and [78] where some properties and typical applications of material in microfluidics are mentioned. The technological aspects of chip manufacturing go far beyond the scope of this article. However, here we mention some reviews that are devoted to the latest progress and perspectives in the field [78–81].
Polydimethylsiloxane (PDMS) and glass are widely used materials that are the most biologically compatible, inert, and suitable for repeated use. It is worth noting some peculiarities when using those materials. It was found and reported that PDMS can leach, and hydrophobic compounds (proteins, or small molecules, like fluorescent dye Nile red) could be absorbed on chip surface [82–84]. Also, the structure of this material makes it gas-permeable (which is an advantage) and makes the evaporation of water easier at the same time. Those effects have a strong influence on the chip cell cultivation process. And, also, leaching and sorption can make additional noise during detection. Some techniques were investigated to overcome these issues, like modification of chip surface or addition of specific oligomers before polymerization [85–87]. However, some of these steps are not easy to perform, and the desired effect is temporary, as reported. A flexible PDMS chip can change shape under the pressure of the liquid, which might be crucial for the chosen specific geometry. Also, all mentioned changes in material properties can make microfluidic processes unstable in time. Glass does not have some of the above-mentioned drawbacks and can hold higher pressures in comparison to PDMS. However, such kind of chips are much more expensive due to more difficult manufacturing process, they are fragile and have zero gas permeability.
The choice of material for MFC should be done considering droplet detection and separation methods, for example, at the stage of separation of single-cell droplets before incubation, which will be discussed in the next sections.
Properties of liquids, emulsion stability, and cultivation
First, the emulsion must be optimized in terms of cell cultivation conditions. Depending on which phase is dispersed and which is continuous, several types of emulsions could be produced and used in microfluidics (dispersed/continuous phases): w/o, oil-in-water (o/w), and multilayered ones (w/o/w, o/w/o, etc.). Feeding medias for Y. lipolytica and P. rhodozyma are water based. That is why the desired types of emulsion could be w/o or w/o/w.
On the one hand, we must find the best feeding media and conditions for cell growth, which does not guarantee the formed emulsion will be stable. On the other hand, the stability of the generation process and the formed emulsion does not mean optimal conditions for cell growth and their viability.
W/o emulsions are usually much less stable than o/w due to the high interfacial area of the dispersed phase. Overtime emulsions can self-separate into two phases through different mechanisms: creaming, coalescence, flocculation, or Ostwald ripening [88]. Usually, the stability of the emulsion is determined visually, microscopically, by particle size analysis, or by charge analysis and rheology measurements [88]. Views on the nature of w/o emulsions were published in [89–93]. Stability factors include oil viscosity, temperature, droplet size, pH of the aqueous medium, presence of modifiers, etc. Besides, some factors, such as changes in the concentration of substances during the incubation process due to cell activity and semipermeable droplet walls, should be considered. Some viable solutions that cover the mentioned difficulties include the addition of specific biocompatible stabilizers [94–97], the formation of alginate capsules [98–101] (see Fig. 5B), or complex multi-layered (w/o/w, etc.) emulsions [58, 102–104] (see Fig. 5A).
A lot of researchers in the field of microfluidics use fluorinated oils as a continuous phase because of their inertness, biocompatibility, and gas permeability. The latest progress on the stability of fluorinated oil emulsions and some specific surfactants was reported in [105–108]. The surface-active biocompatible additions and stabilizers w/o emulsions that are commonly used for emulsion stabilization are polysaccharides, proteins, and chemically synthesized compounds, like Span 80, Tween 80, or polyglycerol polyricinoleate, etc. [90]. Surfactants could be added both to o/w phases as well. Their concentrations may vary in wide range (up to 16% mas. [97]) and allow to get emulsions with droplet sizes up to 100 µm [109]. Emulsion could be stable even for 15 days at 50°C (for 40 μm droplets) in some cases [110]. With such time stability, microdroplets seem to be suitable for the cultivation of Y. lipolytica [111]. The majority of available data indicate two fluorinated oil options: Novec™ 7500 [39, 112–115] or Fluorinert™ FC-40 [40, 116]—it has been tested and demonstrated that microdroplets can be successfully stored on a chip even for 10 days [116].
In some cases, capsulation of droplets for the cultivation of microorganisms could be applicable [117, 118]. The process of capsulation of droplets has drawbacks, such as non-spherical droplets, higher costs of production, toxicity of some organic solvents, and droplet agglomeration [119].
The last-mentioned multilayered emulsions could be used for the selection of slow-growing microorganisms in low-nutrient environments [120]. However, using complex multilayered emulsions is difficult due to challenges in their formation, stability, and reproducibility [93].
In each case, the search for the optimal conditions for cell growth and stability of emulsion and features of droplets’ formation seems to be an independent experimental task. Also, it is difficult to determine the desired droplet size for incubation from the first principles. However, one may look at research on the successful cultivation of other similar microorganisms. One of the most widely researched organisms is Escherichia coli, and microfluidic technology is no exception. Droplet size used for E. coli experiments varies between 10 and 20 µm [39, 121, 122]. Another often-used microorganism for microfluid technology is algae, with microdroplet sizes used ranging from 50 µm for P. tricornutum [40] to 80 µm for Chlorella vulgaris [116]. While yeast microdroplet sizes vary from 30 µm for Y. lipolytica [115] to 65 µm for Saccharomyces cerevisiae [114]. We may suggest the droplet size suitable for yeast cultivation might be in the range of ∼30 µm at the beginning of experiments. These initial conditions for droplet generation should also include oxygen-permeable fluorinated oil with surface-active modifiers such as Pico-Surf™ 1 [114], EA surfactant [112], or FluoroSurfactant 008 [123].
In addition, the need for later safe cell release emulsion breakdown after the microdroplet separation process should be considered as well [124].
Cells encapsulation
The number of droplets in the emulsion depends on the rate and time of the generation process. Both generation frequency and time are limited. On the one hand, generation frequency is limited by physical factors that are discussed above. On the other hand, time for generation has to be limited to prevent cell division before incubation, or some steps should be taken to stop the proliferation. Moreover, the number of mutants to be screened and, consequently, the number of droplets depend on mutagenesis type and cultures’ pre-treatment.
The frequency of mutations significantly depends on the mutation factor and microorganism and varies a lot. For example, it can reach 4.55 × 10−14 per gene per cell for UV-mutagenesis [125] and 1.17 × 10−6 per gene per cell for EMS [126]. The probability of the desired mutation remains unknown. Differences in mutation rates between wild-type yeast species vary from 1.1 × 10−7 to 5.8 × 10−7 [127]. Some simple calculations show that the initial cell number, considering the survival rate, is approximately 10% after EMS mutagenesis and the number of genes of Y. lipolytica is ∼ 6 × 103 [128], which must be ∼104 to give at least one mutant for encapsulation. From this point of view, increasing the number of droplets with mutants for further investigation to ∼106–107 requires ∼1010–1011 cells at the beginning of the experiment. However, the concentration of cells for encapsulation affects the process itself.
Each droplet should contain only one cell so that the characteristics of each microdroplet after incubation may be attributed to the behaviour of a single cell rather than an array. It has been shown that when cells are randomly distributed in a carrier solution, cell encapsulation follows a Poisson distribution [see Equation (2)]:
| (2) |
where P shows the fraction of droplets that will contain X cells. λ is the mean number of cells per droplet and is calculated by multiplying cell concentration by the droplet volume.
The encapsulation efficiency of cells inside droplets of a given size can be calculated using an online calculator [129], based on the initial concentration of cells. Occupation efficiency is around ∼12% for 30 µm single-cell droplets, and ∼87% of them will be empty at the concentration of 107 cells/ml. Some droplets (∼1%) will contain two or more cells inside as well. The latter effect could be even higher, considering that cells may adhere to and aggregate on channel walls [130]. It becomes more concerning as cell culture concentration increases.
Working parameters of the above-mentioned Ray-drop technology (Fig. 4F) are as follows: for w/o droplets with a size of ∼71 μm at a generation rate of ∼445 Hz, flow rates equal to 100 μl/min and 5 μl/min for continuous and dispersed phases, respectively [131] (operating pressure was not specified). So, considering the efficiency of encapsulation, 8 × 106 droplets with approximately 106 mutants inside could be generated after 5 h. Initial cell concentration varies a lot: from 3 × 106 cells/ml [39] to 4 × 108 cells/ml [121], as reported.
The process of encapsulation could be optimized. It might be useful to add some stabilizers to prevent cell aggregation in dispersed phases, like OptiPrep [114], or use methods of manipulation of cells to increase single-cell encapsulation efficiency or to sort out the single-cell droplets. Different methods and techniques were developed for those purposes. An overview of the so-called ‘active’ and ‘passive’ methods for the optimization of the encapsulation process can be found in references [77, 132–136]. As an example, authors [137] improved the cell encapsulation efficiency with a cell size of 14 µm by 72% using the flow-alignment technique.
Since, at this stage of experiment planning, a lot of initial parameters became known, such as the desired size of microdroplets, liquids and chips’ material properties, the method of generation, dimensions of the channels, flow rate of liquids, and frequency of generation can be estimated and adjusted from the initial data. Currently, there is software that allows modelling the final geometry of a microchip from the first principles [138]. This is also needed for the estimation of the total hydrodynamic resistance of a microfluidic system containing both droplet detection and separation parts. Several online tools [139–142] are available to estimate flow parameters for specific channel geometries. These tools also help to calculate some important MFC and hardware characteristics, such as controller and flow sensor operating parameters. One can refer to original process modelling papers [143–147] as well.
Microdroplet detection
The next step for the successful selection of microorganisms is to distinguish microdroplets with the desired cell properties from one another. In other words, one must find a suitable marker. Metabolization of cells and proliferation may change droplet size and physical–chemical parameters of feeding media: changes in concentration of initial components and the appearance of internal or external metabolites (astaxanthin, in the case of P. rhodozyma; lipase, in the case of Y. lipolytica). Consequently, those affect changes in the optical density and electrical conductivity of droplets. Also, the possible appearance of several dozen cells inside a microdroplet after incubation could be interpreted as a mass/concentration heterogeneity—droplets of different sizes and number of cells inside will have different densities. In our case, the choice of detection method will be limited to the use of non-destructive methods without any labelling of cells, as it is undesirable for further use of mutants.
The reviews [148–153] summarize progress in detection methods used in microfluidic droplet systems and discuss the advantages and disadvantages of their use in different cases (some of them are presented in Table 1 [154, 155]). These methods include optical, electrochemical, mass spectrometry, etc. Some less commonly used techniques are published in Ref. [156]. Here we will discuss some methods that seem to be the most promising and suitable for our yeast selection experiments, considering the above-mentioned markers.
Table 1.
Analytical detection techniques for droplet microfluidics [154, 155].
| Analytical method | Sensitivity | Analysis speed | Labelling | Advantages | Disadvantages | Applications |
|---|---|---|---|---|---|---|
| Bright-field microscopy | Poor | Depends on camera speed | No | Imaging the shape, size, colour, trajectory of droplets, and interaction between droplets | Low sensitivity, poor ability for molecule analysis | Droplet generation and manipulation |
|
| ||||||
| Fluorescence microscopy | Good | Fair | Yes | Convenient; Good sensitivity; Quantification | Low analysis speed; Need derivatization | Single-cell and single-molecule analysis |
|
| ||||||
| LIF | Excellent | Excellent | Yes | High sensitivity; compounds quantification; Large dynamic range | High dependence on fluorescent probe design | Single-molecule detection; single-cell analysis; high-throughput sorting and screening |
|
| ||||||
| Laser Raman spectroscopy (LRF) | Good | Good | No | Good sensitivity | Matrix effect | High-throughput detection; bacteria identification |
|
| ||||||
| Absorption spectroscopy | Poor | Good | No | Label-free; compounds quantification | Low sensitivity | Rapid identification of compounds |
|
| ||||||
| Mass spectrometry | Good | Good | No | Simultaneous detection of multiple analytes; Capability of elucidating chemical structures | Matrix effect; Requiring sample pre-treatment | Screening and optimising reaction conditions; enzyme inhibitor |
|
| ||||||
| Photothermal- and optoacoustic spectroscopy | Good | Good | No | Compounds quantification | Matrix effect | Biomedical diagnostic tools; enzymatic assay |
|
| ||||||
| FTIR spectroscopy | Good | Good | No | Simultaneous detection and quantification of multiple analytes | Requiring sample pre-treatment; matrix effect | Chemical reactions study |
|
| ||||||
| Nuclear magnetic resonance spectroscopy | Poor | Poor | No | Capability of elucidating chemical structures | Requiring sample pre-treatment | Rapid identification of compounds |
|
| ||||||
| Electrochemical detection | Good | Good | Yes | Low cost; Simple structure; Small size; Good sensitivity | Need derivatization, poor reproducibility | Measuring the size, frequency, and velocity of droplets |
|
| ||||||
| Impedance-based detection | Good | Good | No | Low cost; Simple structure; Small size | Matrix effect | Measuring size, number of cells inside droplets |
|
| ||||||
| Capillary electrophoresis | – | Fair | Yes | Separation of multiple analytes | Need derivatization with fluorescence detection | Separation of amino acid; enzyme assay |
Droplets’ size
Obviously, if droplet size changes after incubation, it could be noticed and measured microscopically. As shown [157], the difference in volume between ‘empty’ (without cells) and inoculated hydrogel droplets was significant after cultivation. The equivalent at the beginning of incubation, empty droplets remained the same at ∼144 pL and inoculated by S. cerevisiae droplets size was ∼65 pL, which is equivalent to 79% of the initial diameter. Growth-induced droplet size-decreasing phenomena were observed for various microorganisms as well [158–161]. As mentioned by the authors [160], this phenomenon depends on several factors, like droplet volume, medium content and concentration of substances, number of cells, incubation time, and osmosis (see also Fig. 6A).
Figure 6.
Cells behaviour during incubation (A) (image adapted from [43]) and principal scheme of DLD sorting method (B) (image adapted from [171, 172]): (A) Droplets’ size reduction due to different cell metabolism and division: at the beginning, all droplets are uniform in size; the largest change is caused by metabolizing and dividing cells, smaller changes are caused by metabolizing and non-dividing cells, while arrested cells do not cause droplet size reduction; (B) two separate modes of particle flow types through chip—zig-zag and bump/displacement mode. The chip contains pillars distributed with a horizontal shift to produce a periodic streamline pattern in laminar flow. It causes smaller particles to flow through pillars, while larger particles are more likely to bump, which displaces them in one direction.
On the other hand, there are inertial-based methods for particle separation already known in industry, and the effects of such techniques were revealed in microfluidics, too. This part of microfluidic technology is known as inertial microfluidics—a description of it and the occurred effects can be found in [162–169]. Methods developed on this basis are known as passive methods. And particles with different characteristics under inertial forces are self-detected and separated at the same time. Here we discuss some methods that partially touch separation techniques too.
A technique known as deterministic lateral displacement (DLD) [170, 171] (see Fig. 6B) was used by the authors [172] for the separation of ∼23 µm droplets with S. cerevisiae inside from ∼30 µm empty droplets at a rate of approximately 12 000 droplets per second. Other authors [158, 173] used viscoelastic effects for sorting, too: after the incubation period, empty droplets were successfully separated from encapsulated E. gracilis droplets with efficiency of 93.6% (see also Fig. 7) [158].
Figure 7.
Size-based separation of droplets due to lateral inertial focusing (image adapted from [158]). (A) A view of an inertial microfluidic channel. (B) Scheme (upper) of the microfluidic device with outlets O1–O5 and illustration of the lateral distribution of droplets of different sizes (down) at three indicated regions (i), (ii), and (iii).
Currently, DLD devices are developed through numerical simulation and experimental validation [174, 175]. However, some crucial factors must be known. One may suggest that droplets with different proliferation activity of cells may have varied sizes after cultivation (multimodal droplet sizes). Also, small experimental data were published to predict how big those differences could be after cultivation in the cases of Y. lipolytica and P. rhodozyma. This means the DLD chip must be adjusted and developed twice. Moreover, cells may consume the medium without division, also resulting in a decrease in droplet sizes [176] (see Fig. 6A). Some experiments on cell behaviour during incubation inside droplets must be performed to predict the possibility of this method’s implementation. Nevertheless, the mentioned drawbacks could possibly be covered by methods that allow multimodal particle sorting [177–179].
The inertial forces that arise during the movement of liquid in channels of a special geometry contribute to the movement of particles immersed in it in the cross-section of the channel [166, 180] (see Fig. 8). Thus, the particles/droplets are concentrated near one of the walls of the channel, where they can be detected and collected in some way later.
Figure 8.
Inertial focusing of particles (image adapted from [166])—with a random order of particles at the beginning (to the left, 1), one may reach filtration (to the right, 2 top) or fractionation (to the right, 2 down) by adjusting flow velocity. Separation is achieved through Dean drag and inertial lift forces in the channel.
Optical and spectroscopic detection methods
Remain the most widely used due to their versatility, contact-free, and non-destructive nature, but may have a low signal-to-noise ratio [152, 181–183]. The classical adsorption method of biomass concentration measurement as optical density has long been known and widely used. However, adsorption and fluorescence, when moving to the microscale, significantly lose sensitivity due to a significant reduction in the length of the optical path. There is an example of work where the optical path was increased by partial deformation of the droplet and a change in the geometry of the channel (Z-channel) [184]. Also, there are techniques known as flow cytometry (FC) [185–187], fluorescent-activated droplet sorting (FADS) [188–190], or laser-induced fluorescence (LIF) [191] for single-cell/droplet analysis and sorting. Those techniques utilize lasers on one or several wavelengths to produce scattered and fluorescent light signals from a single unit. If one can make droplet fluorescent, this increases sensitivity of detection and selection.
As mentioned, internal metabolite—astaxanthin has strong fluorescence, and this property was used for the successful selection of carotenoids hyperproducing P. rhodozyma [192] and Xanthophyllomyces dendrorhous [193] mutants. The laser tweezers Raman spectroscopy was used for rapid quantification of total carotenoids in single cells of Rhodotorula glutinis [194] as well. This method is sensitive to the chemical composition of the cell [195].
Increased production of biomass of astaxanthin-producing strain of P. rhodozyma is of interest, too. When using only astaxanthin production as a biomarker, one should consider that droplets with high biomass-producing strain may have the same (or lower) fluorescence intensity as astaxanthin-hyperproducing strains with lower biomass content. Nevertheless, fluorescence could be used as an additional factor for further selection of sorted droplets: high biomass production strain with exceptionally low astaxanthin production is out of interest.
Droplets can be made fluorescent when an extracellular compound reacts with a specific reagent and forms a fluorescent product. For example, high ethanol-producing cyanobacteria was successfully selected in microdroplets by pico-injection of an enzymatic assay. It converts ethanol into a highly fluorescent compound, resorufin [196]. In the case of Y. lipolytica, the concentration of extracellular lipase might be measured using the same technique by lipolysis of the p-nitrophenyl esters that give yellow-coloured p-nitrophenol, measured at 405–410 nm [197]. For example, strains of Y. lipolytica with high-active heterologous enzyme secretion were studied using BODIPY®FL: hydrolysis releases fluorophores, revealing enzyme activity inside droplets [115]. Another example [198]: the population of Bacillus subtilis was screened by decreasing droplet fluorescence as soon as enzymes were able to hydrolyse a fluorogenic substrate, already present in media.
Also, a method of co-cultivation of microorganisms was used for selection of droplets: one developed a FADS co-culture pipeline for improving erythritol production in Y. lipolytica: the pico-injection of fluorescence-based erythritol-biosensing E. coli was used to make fluorescence droplets [199].
Another optical method, like light-scattering-based droplet screening, could be used for the detection and identification of droplets as well [200]. For example, authors [201] used scattered laser light from nanolitre droplets with different encapsulated cell proliferation activities and demonstrated reliable detection for 12 different bacterial species at 1.2 kHz. Some drawbacks, like high noise levels of scattered light from the w/o surface, could be overcome using special types of oils to make differences in refractive indexes of liquids smaller [202].
The method of optical recognition in the bright/dark field using machine learning (ML) and artificial intelligence (AI) remains the most universal [203–208]. The detection algorithm can be easily modified for different cells/particles without changing other microfluidic system components. Sorting performance is limited by the speed of the optical camera and the image processing in the absence of other limiting factors, such as flow rate and the inertia of the sorting device. As an example, optical recognition and image processing were used for investigations of biomass growth inside droplets by [157, 209, 210], etc.
Electrochemical methods
Electrochemical methods could be used for droplet detection as soon as the concentration of substances inside the droplet changes, and this affects electromagnetic conductivity and permeability of media. Methods include techniques like amperometric detection, capillary electrophoresis, conductivity-based detection, cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS) [211–217]. They are characterized by obvious advantages: label-free, have high speed of detection, relative ease of manufacturing.
As an example, the authors of the paper [213] used differences in the impedance for recognition of droplets with and without cells (see Fig. 9). They were able to distinguish w/o droplets of ∼40 µm even with different numbers of cells inside and showed that sensitivity and reliability of this type of analysis depend on the electrical conductivity of feeding media. If the conductivity of internal media is higher than >1.6 S/m, the difference in impedances becomes negligible. Cultured microdroplets of yeasts are large, and the feeding media can have an electrical conductivity of ∼2 S/m [218], what makes this method difficult to apply when nutritionally rich mediums with various salts are used. However, the ability to improve the encapsulation efficiency makes this method attractive. Cylindrical (wrap-around) electrodes are more sensitive [219], but such a configuration makes the channel non-transparent.
Figure 9.
Principal electrical scheme of a droplet in the channel for EIS (image adapted from [220]): C, R—electrical capacitance and resistance, respectively.
It is worth noting that high-frequency electromagnetic fields should be used with caution as they may negatively affect cell viability [221, 222] due to the instability of cell membranes.
The last-mentioned in this chapter marker is the appearance of mass/concentration heterogeneities inside microdroplets in the form of new cells, what affects changes in the droplet centre of inertia and density. And, of course, the appearance of new cells could be detected microscopically as well.
As mentioned above (see Fig. 8), inertial forces can move particles to the channel wall. The same effect touches cells that move to the w/o interface inside the droplet. This gives the possibility to split it into several parts (see Fig. 10) [223]. One can obtain higher cell concentration inside one part of a droplet, and this allows the possibility to analyse the rest of it (the second part) by chromatography, spectroscopy, etc. (see Table 1). This method was used by Tenje et al [224], for example. One may refer to [223, 225–230] where this kind of technique was used too. However, such a technique requires high-precision particle manipulation and storage for referring correlation between two parts of the same droplet.
Figure 10.

Splitting of the droplet (image adapted from [223])—the sizes of split-off droplets (VA and VB) are determined by the flow rate ratio of Q2 and Q1 in microchannels.
Finally, it is worth mentioning a density-dependent sorter developed by Nam et al. [231]: same size ∼150 μm alginate droplets, but with different number of encapsulated cells inside, were separated using a standing surface acoustic wave at a rate of 2300 droplets per second. This technique is known as acoustophoresis. It is suitable for sorting many particles at the same time.
Acoustic pressure applied to the liquid in the channel causes a wave in it. This wave forms pressure nodes—a unique acoustic field inside a channel. A particle takes a position in this field due to its size and density/compressibility. The technique allows manipulation of particles ranging in size from a few nanometres to hundreds of micrometres [232, 233]. There are different modifications, known as standing surface (SSAW) [234, 235], bulk (BAW) [236], and travelling surface (TSAW) [237] acoustic waves. The scheme of acoustophoresis for SSAW (as an example) is presented in Fig. 11A [238, 239].
Figure 11.
Acoustic methods and their modifications (images adapted from [238, 239]): SSAW device scheme is shown (to the top left), and the separation mechanism is shown (to the top right). (A) Acoustic forces applied from interdigital transducer (IDT) move bigger particles to pressure nodes; (B) an IDT under the microchannel was used to separate polystyrene particles of varied sizes (image adapted from [240]).
Acoustophoresis does not require labelling, has a negligible effect on cell viability, and is suitable for particle sorting in the array with high throughput, as described in [240] (see Fig. 11B).
Microdroplet sorting
The last step is to separate the target droplets from the array. Recognition and sorting speed are important in our case—a higher number of mutants/droplets can be screened since cells continue proliferation during the process. Mutants in those droplets can achieve higher biomass concentration, causing false-positive separation. That is why a fast selection of desired droplets from the array is very desirable. Some possibilities for such types of solutions were described above. However, there are methods that allow the manipulation of single droplets or particles in microfluidic channels, too.
To date, all methods of particle separation in microfluidics are classified as passive and active. As mentioned above, passive methods rely on inertial forces in microchip channels. Active methods require the application of an external field. External forces or fields may include, for example, temperature or concentration gradient, electrical and/or magnetic field, acoustic waves, optical beams, or pneumatic flow control, etc. [220, 241–244]. Some of them are applicable to the separation of objects, like cells, and others are suitable for droplet separation. Here we will consider the methods suitable for the separation of droplets with the size of tens of microns.
Hydrodynamic (pressure-controlled) method
The method is based on controlling the flow of liquid in the channel by changing the external pressure. The most common are two schemes approaches: (i) flexible membrane that simply closes or opens cross-section of the channel [245, 246] also called valves with ‘positive’ or ‘negative’ pressure (see Fig. 12A) [220] or (ii) deflection of the target particle by an additional external flow of liquid—the so-called ‘on-chip sorting’ because of the presence of a collecting camera on a chip (see Fig. 12B) [168, 247]. The advantage of this method is the absence of any influence on the viability of cells and the independence from the size of the sorted particles. The size of the particles that can be sorted using this method could be hundreds of microns but with a low frequency [232, 248]: maximum sorting speed reached ∼2 Hz for 800 µm particles. The expected sorting rate using this method will be approximately in kHz for 40 µm droplets.
Figure 12.
Pressure-controlled methods for droplet separation (images adapted from [220, 247]): (A) droplet sorting is assisted by controlling pressure: negative pressure in the valve causes expansion of the channel and ‘hit’ droplet to continue to flow through the lower microchannel. Positive pressure causes collapse and blocks the lower microchannel, causing droplet flow through the upper microchannel; (B) sorting is performed by pressurized air that deflects ‘hit’ droplets from the initial path to the collection reservoir on-chip that can carry liquids such as culture medium, oil, buffers, etc.
Dielectrophoresis (DEP)
Forces that cause particle/droplet movement appear in a non-uniform electric field due to their polarization. Reviews [249–253] present basics and recent progress in this field. The method does not require external labelling. It is suitable for sorting large w/o droplets [254]. However, the method must be used with precautions: the electromagnetic field can have a negative effect on the viability of cells, as mentioned before and must be adjusted to prevent splitting droplets. The latter effect is also used to control their size [255, 256]. There are different high-throughput sorting device modifications [254, 257–259], where the mentioned negative effects were minimized (see Fig. 13). The authors [254] were able to establish the dependence of the sorting efficiency from droplet’s size for this type of device: the product of multiplication of the droplet volume on the sorting frequency is constant and equals to about 400 000. Based on this, the expected sorting speed will be approximately 5–6 kHz in our experiments.
Figure 13.
DEP method and several configurations of electrodes (image adapted from [254]): (A) one of the possible configurations of electrodes for droplet sorting; (B) configuration of the periodical structure of switching on–off positive and grounded electrodes when the applied electromagnetic field has a much lower intensity. When applied on a long droplet path, one can reach the desired displacement.
It is worth mentioning the appliance of a non-uniform electric field to sort out a considerable number of cells, as proposed in ref. [251] and presented in the case of droplets in Fig. 14. Droplets, in the same way as cells, can be characterized by different electrical conductivity, which depends on cell numbers inside and their activity after incubation. This technique has drawbacks—high deformability (and therefore the possibility of merging/break up) of bigger droplets and the large number of them near cylindrical electrodes, which may cause a shielding effect and bring difficulties during sorting.
Figure 14.
DEP-based sorter scheme: asymmetric electrodes cause a non-uniform electromagnetic field. Under this field, droplets move accordingly to the conductivity of internal media (changes in field in the presence of droplets are not shown). Droplets with higher conductivity move close to the cylindrical electrodes with higher tension of electric field, while droplets with lower conductivity—to the flat electrodes.
Acoustophoresis
This method was described in the previous chapter. Here we mention the version of TSAW application: the so-called ‘acoustic valve’—an acoustic wave creates an impulse in the liquid that deflects the particle from its initial trajectory [260].
Microfluidic system configurations for accelerated selection of mutants
Here, we will briefly represent and discuss several already published microfluidic system configurations (with methods of detection and separation) used for the selection and screening of microorganisms inside droplets. Table 2 presents some papers devoted to similar experiments.
Table 2.
Microfluidic system configuration for accelerated microorganism selection.
| Microorganism | Microdroplet generation/cultivation conditions | Detection and separation | Ref. |
|---|---|---|---|
| Yeast ST4058 | Microdroplet size—35 µm (22 pl); oil—HFE-7500; surfactant—EA (1.0%); Incubation: in a syringe for 7 hours | Optical observation, co-cultivation with gene-modified fluorescent E. coli; FADS, electric filed sorter | [112] |
|
| |||
| Cyanobacteria Synechocystis | Microdroplet size—50 µm (65 pl); oil—HFE-7500 (3M), surfactant—PicoSurf2 (2.5%); flow focusing, PDMS; cell-density (cells/ml)—1.8*106; Incubation: in syringe for 4 days, 30°C; 80 μmol photons m–2*s–1 |
|
[113] |
|
|
|||
| Algae C. reinhardtii |
|
||
|
| |||
| Yeast Y. lipolytica | Microdroplet size—34 µm (20.6 pl); oil—Novec7500, surfactant—KryJeffD900 (2.5%); cell density (cells/ml)—3.48*108; microdroplet generation productivity (cells/s)—3000; Incubation: in glass vial at 28°C, 1 day | Pico-injection of fluorogenic substrate, LIF electric field sorting system | [115] |
|
| |||
| Algae C. vulgari, Ch. reinhardtii, |
|
Image-based processing and observation of biomass growth | [116] |
|
| |||
| Bacteria E. coli |
|
Optical observation, co-cultivation with E. coli; FADS | [121] |
|
| |||
|
Microdroplet size—45–95 µm (48–449 pl); | Inertial passive sorter | [158] |
|
| |||
| Yeast S. cerevisiae | Microdroplet size—30 µm (14 pl); oil—HFE-7500, EA-surfactant (0.5%); flow focusing, PDMS; cell density (cells/ml)—2*106 | Optical and LIF observations, DLD passive sorter | [172] |
|
| |||
| Cyanobacteria Synechocystis sp. PCC 6803 | Microdroplet size—90 µm (380 pl); oil—HFE-7500, Picosurf-1 (2.50%); flow focusing, PDMS; cell density (cells/ml)—5.24*106; Incubation: on-chip, 4 days | Inverted microscope observation with image processing, LIF-detection of chlorophyll fluorescence | [196] |
|
| |||
| Yeast Y. lipolytica | Microdroplet size—30 µm (14 pl); microdroplet generation productivity (cells/s)—2000; Incubation: 36 h, 30°C | Co-cultivation with E. coli, FADS; optical inspection and electric field sorting system | [199] |
|
| |||
| Yeast P. rhodozyma | Microdroplet size—30 µm (14 pl); mineral oil; Span80 (2.5%); T-junction, PDMS; cell density (cells/ml)—1.5*106; Incubation: in 2 ml tubes, 40 h, 30°C | Image-based processing sorter with pneumatic control | [261] |
|
| |||
| Gut anaerobes | Microdroplet size—65–115 µm (143–796 pl); flow focusing; low cell density—2–12% single-cell droplets | Image-based processing sorter with an electric field sorting system | [262] |
Here, we will focus on discussing concepts that could lead to new, more efficient chip designs. One consideration is the increase in the number of microdroplets that need to be screened in a short period of time, as we believe that this is the limiting factor—as was shown above, this number must be huge for the successful selection of a few new mutants. Each single cell must be encapsulated with high precision in an individual microreactor using a single microchannel. Therefore, the only feasible way to increase the number of microreactors is the use of several parallel devices (or parallel microchannels on one chip). It is obvious that the hydrodynamic resistance of such a system will be high and limited both by the parameters of the pump and the permissible load on the chip. From the analysis of the published papers (see Table 2), the chip’s design consists of one channel for the generation of droplets with a low initial concentration of the cell culture. Increasing the number of pumps requires more investment. Nevertheless, there are projects that try to make microfluidics less expensive and simply available for users [263, 264]. This is the first limitation factor on the way to increasing the number of microreactors in one experiment. As for the accuracy of this process—each channel can be supplied by passive or active control methods of droplet generation. In this case, encapsulation becomes a stand-alone process on a chip that has all the characteristics of a complete microfluidic system—generation of microdroplets, detection, and selection. On the other hand, such a complex construction has benefits, like significantly reducing the number of microdroplets for later screening by removing unnecessary droplets (including those contaminated by other species). It is interesting to construct a microfluidic system in such a way that the same chip can be used for two purposes. First, an integrated detection/separation system could be used to increase droplet generation precision prior to incubation. Secondly, the same chip is used to select droplets with the highest number of cells (highest biomass content). Such a system must be able to sort droplets using several parameters.
The next steps are recognition and selection. At this stage, the variability of the system increases significantly—the number, size, and content of droplets after incubation vary so widely that it becomes difficult to build a device that can sort droplets by a single parameter and, at the same time, be resistant to noise in the system. Optical observation with image processing software or laser-induced fluorescence and droplet sorting based on this (LIF, FADS) are, therefore, still the most common methods for control at this stage (see Table 2). An often-used method of separation of a single drop is an electric field. Optical methods, however, are characterized by low throughput: in the camera–controller–sorter link, the slowest and most expensive element remains the camera since electric sorters are capable of operating at MGz frequencies. Although the operating frequency of today’s fastest SCARF camera in the world is an impressive 156 TGz [265], the cost of an ‘entry’ level high-speed camera is around 60–80 thousand USD (Phantom TMX 5010, 50720 fps at 1280 × 800) [266].
A MFC for high-throughput droplet selection can be based on passive methods such as DLD, DEP, or SSAW separation. Such configurations seem to be most suitable for sorting an array of droplets, albeit at the cost of lower accuracy. Further droplet selection steps can include optical (with image processing and/or ML, AI-assisted software) or FADS as described above. In this step, several parallel microchannels are also preferred to increase throughput.
Combinations of several microfluidics methods are known as hybrid methods. Some of them (e.g. DLD and electric field) are described in [267–270]. An interesting alternative is the application of ML to control external fields (acoustic or electric)—in this case, manipulation of particles can be achieved without prior information about the shape of the field [271–273]. A recent collection of 36 articles devoted to AI in microfluidics shows growing interest in the field [274]. Automated image processing can help achieve greater accuracy and performance in droplet microfluidics [275]. In our opinion, hybrid systems are the most promising in future experiments on the accelerated selection of various microorganisms, including yeasts.
As for increasing the accuracy and selectivity and expanding the limits of already existing microfluidic technologies for accelerated mutant screening, some methods should also be considered. For example, for the search for new, more effective chromophores, new materials and solutions for easier integration of active components with chips, as well as reducing the cost of microchip manufacturing technology. Microscopic methods are present at every stage of microfluidics, and it is not possible to avoid them completely. So, increasing the availability of high-speed cameras in combination with ML/AI will also make this technology more accessible and efficient.
Also, we would like to mention cell-line contamination, which is not a trivial problem and brings significant experimental errors in biology and medicine [276] and is costly [277]. It could not be avoided completely in microfluidics, too. One of the viable solutions to avoid cross-contamination is using a single-use chip [278] and reducing its cost is preferable in such a case. If yeast is used, various antibiotics in the water-based medium can be applied, but if droplet incubation and sorting take prolonged periods of time, antibiotic potency wears off.
Contamination of cell culture in droplet microfluidics could be prevented before droplet generation—as it was mentioned above, in addition to microscopy, the EIS method could be used for single-cell screening, based on its unique properties [279]. This method requires the creation of specific libraries for microorganism screening and has some disadvantages as described earlier. Also, it is possible that droplets will be contaminated despite efforts made, and they can include unnecessary cells after cultivation. Droplets must be screened after incubation. So, if unnecessary cell morphology differs significantly from the used strain, it could be revealed microscopically, and the use of AI-assisted image processing can help reduce time to achieve purity of cell line.
Conclusions
It was found that using permeable to oxygen water-in-fluorinated-oil emulsion with stabilizers seems to be most promising both for Y. lipolytica and P. rhodozyma cultivation conditions using microfluidics. The droplet size suitable for both microorganism growth is in the range of ∼34 μm. Available data indicate that EMS mutagenesis is a promising route for creating mutants considering mutation rates and methods compatibility to droplet generation.
Different techniques and methods suitable for accelerated selection of mutants after incubation in microdroplets were discussed. Methods were chosen considering specific biomarkers of microorganisms (astaxanthin and lipase) and the expected growth of cells inside droplets. Based on literature review, other changes in droplet’s characteristics after incubation were discussed as well—size, mass, optical density, concentration of feeding media, and electrical conductivity.
Possible conceptual designs of MFCs and future perspectives of accelerated selection of yeast mutants based on microdroplets were discussed. We found possibilities to apply sorting techniques known as DLD, DEP, and SSAW to the array of droplets after incubation. They allow one to compose high-throughput microfluidic devices for detection and selection of mutants. Those hybrid methods are more complex but have high throughput and can include LIF, FADS, and AI-assisted image processing. They are the most promising technologies for accelerated selection of microorganisms, including yeasts.
Contributor Information
Taras Mika, Institute of Energy Systems and Environment, Riga Technical University, 12 – K1 Āzene street, Riga, LV-1048, Latvia.
Martins Kalnins, Institute of Energy Systems and Environment, Riga Technical University, 12 – K1 Āzene street, Riga, LV-1048, Latvia.
Kriss Spalvins, Institute of Energy Systems and Environment, Riga Technical University, 12 – K1 Āzene street, Riga, LV-1048, Latvia.
Author contributions
Taras Mika (Conceptualization [equal], Visualization [supporting], Writing—original draft [lead], Writing—review & editing [equal]), Martins Kalnins (Conceptualization [supporting], Visualization [lead], Writing—original draft [supporting], Writing—review & editing [equal]), Kriss Spalvins (Conceptualization [equal], Funding acquisition [lead], Project administration [lead], Supervision [lead], Writing—review & editing [equal])
Funding
The work has been developed by the Fundamental and Applied Research Project ‘Herbicides as tool for selection of edible protein-rich mutants’, project No. lzp-2022/1-0126, funded by the Latvian Council of Science.
Conflict of Interest
The authors declare no conf lict of interest.
References
- 1. Branduardi P, Porro D.. Yeasts in biotechnology. In: Feldmann H. (Ed.).Yeast. New Jersey: Wiley, 2012, ch. 14, 347–70. [Google Scholar]
- 2. Steensels J, Snoek T, Meersman E. et al. Improving industrial yeast strains: exploiting natural and artificial diversity. FEMS Microbiol Rev 2014;38:947–95. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3. Johnson EA. Phaffia rhodozyma: colorful odyssey. Int Microbiol 2003;6:169–74. [DOI] [PubMed] [Google Scholar]
- 4. Raita S, Feldmane L, Kusnere Z. et al. Microbial carotenoids production: strains, conditions, and yield affecting factors. Environ Climate Technol 2023;27:1027–48. [Google Scholar]
- 5. Johnsosn EA, Lewis MJ.. Astaxanthin Formation by the Yeast Phafia rhodozyma. J Gen Microbiol 1979; 115(1):173–83.
- 6. Mussagy CU, dos Santos A, Militão F. G. G. et al. Phaffia rhodozyma biorefinery: a sustainable pathway to obtain natural pigments and production of methane biogas as renewable fuel. Chem Eng J 2023;473:145350. [Google Scholar]
- 7. Bjørklund G, Gasmi A, Lenchyk L. et al. The role of astaxanthin as a nutraceutical in health and age-related conditions. Molecules 2022;27:1–17. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8. Mussagy CU, Kot A, Dufossé L. et al. Microbial astaxanthin: from bioprocessing to the market recognition. Appl Microbiol Biotechnol 2023;107:4199–215. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9. Amaral PFF, da Silva JM, Lehocky M. et al. Production and characterization of a bioemulsifier from Yarrowia lipolytica. Process Biochem 2006;41:1894–8. [Google Scholar]
- 10. da Silva JL, Sales MB, de Castro Bizerra V. et al. Lipase from Yarrowia lipolytica: prospects as an industrial biocatalyst for biotechnological applications. Fermentation 2023;9:581. [Google Scholar]
- 11. Madzak C. Yarrowia lipolytica strains and their biotechnological applications: how natural biodiversity and metabolic engineering could contribute to cell factories improvement,. JoF 2021;7:548. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12. Miller KK, Alper HS.. Yarrowia lipolytica: more than an oleaginous workhorse. Appl Microbiol Biotechnol 2019;103:9251–62. [DOI] [PubMed] [Google Scholar]
- 13. Lederberg J. A simple method for isolating individual microbes. J Bacteriol 1954;68:258–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14. Bai Y, Gao M, Wen L. et al. Applications of microfluidics in quantitative biology. Biotechnol J 2018;13:e1700170. [DOI] [PubMed] [Google Scholar]
- 15. Nikshad A, Aghlmandi A, Safaralizadeh R. et al. Advances of microfluidic technology in reproductive biology. Life Sci 2020;265:118767. [DOI] [PubMed] [Google Scholar]
- 16. Van Der Meer AD, Poot AA, Duits MHG. et al. Microfluidic technology in vascular research. J Biomed Biotechnol 2009;2009:823148. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17. Cui P, Wang S.. Application of microfluidic chip technology in pharmaceutical analysis: a review. J Pharm Anal 2019;9:238–47. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18. Convery N, Gadegaard N.. 30 years of microfluidics. Micro and Nano Engineering 2019;2:76–91. [Google Scholar]
- 19. Ren Y. (ed.). Advances in Microfluidic Technologies for Energy and Environmental Applications. Rijeka: IntechOpen, 2020. [Google Scholar]
- 20. Patel D. Exploring the Frontiers of Microfluidics. In: Singh R.K., Phanden R.K., Sikarwar B.S. (eds) Advances in MEMS and Microfluidic Systems. Pennsylvania: IGI Global, 2023, ch. 2, 11–31. [Google Scholar]
- 21. Zhuang Y, Jiang GL, Zhu MJ.. Atmospheric and room temperature plasma mutagenesis and astaxanthin production from sugarcane bagasse hydrolysate by Phaffia rhodozyma mutant Y1. Process Biochem 2019;91:330–8. [Google Scholar]
- 22. Miao LL, Chi S, Hou TT. et al. The damage and tolerance mechanisms of Phaffia rhodozyma mutant strain MK19 grown at 28 °C. Microb Cell Fact 2021;20:5–13. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23. Najafi N, Ahmadi AR, Hosseini R. et al. Gamma irradiation as a useful tool for the isolation of astaxanthin-overproducing mutant strains of Phaffia rhodozyma. Can J Microbiol 2011;57:730–4. [DOI] [PubMed] [Google Scholar]
- 24. Bordes F, Cambon E, Dossat-Létisse V. et al. Improvement of Yarrowia lipolytica lipase enantioselectivity by using mutagenesis targeted to the substrate binding site. ChemBioChem 2009;10:1705–13. [DOI] [PubMed] [Google Scholar]
- 25. Park BG, Kim J, Kim E-J. et al. Application of random mutagenesis and synthetic FadR promoter for de novo production of ω-Hydroxy fatty acid in Yarrowia lipolytica. Front Bioeng Biotechnol 2021;9:624838. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26. Katre G, Ajmera N, Zinjarde S. et al. Mutants of Yarrowia lipolytica ncim 3589 grown on waste cooking oil as a biofactory for biodiesel production. Microb Cell Fact 2017;16:176–14. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27. Yu Q, Li Y, Wu B. et al. Novel mutagenesis and screening technologies for food microorganisms: advances and prospects. Appl Microbiol Biotechnol 2020;104:1517–31. [DOI] [PubMed] [Google Scholar]
- 28. Singer B, Kuśmierek JT.. Chemical mutagenesis. Annu Rev Biochem 1982;51:655–93. [DOI] [PubMed] [Google Scholar]
- 29. Ikehata H, Ono T.. The mechanisms of UV mutagenesis. J Radiat Res 2011;52:115–25. [DOI] [PubMed] [Google Scholar]
- 30. Ma L, Kong F, Sun K. et al. From classical radiation to modern radiation: past present, and future of radiation mutation breeding. Front Public Health 2021;9:768071. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31. Kodym A, Afza R.. Physical and chemical mutagenesis. Methods Mol Biol 2003;236:189–204. [DOI] [PubMed] [Google Scholar]
- 32. Goosen N, Moolenaar GF.. Repair of UV damage in bacteria. DNA Repair (Amst) 2008;7:353–79. [DOI] [PubMed] [Google Scholar]
- 33. Balasubramanian S, Chen J, Wigneswaran V. et al. Droplet-based microfluidic high throughput screening of Corynebacterium glutamicum for efficient heterologous protein production and secretion. Front Bioeng Biotechnol 2021;9:668513–2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34. Bowman EK, Wagner JM, Yuan S-F. et al. Sorting for secreted molecule production using a biosensor-in-microdroplet approach. Proc Natl Acad Sci U S A 2021;118(36):e2106818118. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35. Sega GA. A Review of the Genetic Effects of Ethyl Methanesulfonate. Mutat Res 1984; 134(2-3):113–42. [DOI] [PubMed]
- 36. Mans R, Daran JMG, Pronk JT.. Under pressure: evolutionary engineering of yeast strains for improved performance in fuels and chemicals production. Curr Opin Biotechnol 2018;50:47–56. [DOI] [PubMed] [Google Scholar]
- 37. van Tatenhove-Pel RJ, Hernandez-Valdes JA, Teusink B. et al. Microdroplet screening and selection for improved microbial production of extracellular compounds. Curr Opin Biotechnol 2020;61:72–81. [DOI] [PubMed] [Google Scholar]
- 38. Fickers P, Destain J, Thonart P.. Improvement of Yarrowia lipolytica lipase production by fed-batch fermentation. J Basic Microbiol 2009;49:212–5. [DOI] [PubMed] [Google Scholar]
- 39. Duarte JM, Barbier I, Schaerli Y.. Bacterial microcolonies in gel beads for high-throughput screening of libraries in synthetic biology. ACS Synth Biol 2017;6:1988–95. [DOI] [PubMed] [Google Scholar]
- 40. Yu Z, Geisler K, Leontidou T. et al. Droplet-based microfluidic screening and sorting of microalgal populations for strain engineering applications. Algal Res 2021;56:102293. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41. Li C, Humayun M, Walker GM. et al. Under-oil autonomously regulated oxygen microenvironments: a goldilocks principle-based approach for microscale cell culture. Adv Sci 2022;9:1–19. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42. Zurek PJ, Hours R, Schell U. et al. Growth amplification in ultrahigh-throughput microdroplet screening increases sensitivity of clonal enzyme assays and minimizes phenotypic variation. Lab Chip 2021;21:163–73. [DOI] [PubMed] [Google Scholar]
- 43. Woronoff G, Nghe P, Baudry J. et al. Metabolic cost of rapid adaptation of single yeast cells. Proc Natl Acad Sci U S A 2020;117:10660–6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44. Zamani L, Lundqvist M, Zhang Y. et al. High cell density perfusion culture has a maintained exoproteome and metabolome. Biotechnol J 2018;13:e1800036. [DOI] [PubMed] [Google Scholar]
- 45. Theberge AB, Courtois F, Schaerli Y. et al. Microdroplets in microfluidics: an evolving platform for discoveries in chemistry and biology. Angew Chem Int Ed Engl 2010;49:5846–68. [DOI] [PubMed] [Google Scholar]
- 46. Ding Y, Howes PD, Demello AJ.. Recent advances in droplet microfluidics. Anal Chem 2020;92:132–49. [DOI] [PubMed] [Google Scholar]
- 47.Microfluidic Pumps – Types, Accuracy And Applications. https://www.elveflow.com/microfluidic-reviews/microfluidic-flow-control/high-accuracy-microfluidic-pumps/. (2 April 2024, date last accesed).
- 48. Su W, Han B, Yeboah S. et al. Fabrication of Monodisperse Droplets and Microcapsules Using Microfluidic Chips: a Review of Methodologies and Applications. Reviews in Chemical Engineering 2024; 40(3): 401–434.
- 49. Yao J, Lin F, Kim HS. et al. The effect of oil viscosity on droplet generation rate and droplet size in a T-Junction microfluidic droplet generator. Micromachines (Basel) 2019;10(12):808. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 50. Zhu P, Wang L.. Passive and active droplet generation with microfluidics: a review. Lab Chip 2017;17:34–75. [DOI] [PubMed] [Google Scholar]
- 51. Elvira KS, Gielen F, Tsai SSH. et al. Materials and methods for droplet microfluidic device fabrication. Lab Chip 2022;22:859–75. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52. Schmid L, Franke T.. SAW-controlled drop size for flow focusing. Lab Chip 2013;13:1691–4. [DOI] [PubMed] [Google Scholar]
- 53. Schmid L, Franke T.. Acoustic modulation of droplet size in a T-junction. Appl Phys Lett 2014;104:133501. [Google Scholar]
- 54. Tan SH, Semin B, Baret JC.. Microfluidic flow-focusing in AC electric fields. Lab Chip 2014;14:1099–106. [DOI] [PubMed] [Google Scholar]
- 55. Yin Z, Huang Z, Lin X. et al. Droplet generation in a flow-focusing microfluidic device with external mechanical vibration. Micromachines 2020;11(8):743. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56. Miralles V, Huerre A, Williams H. et al. A versatile technology for droplet-based microfluidics: thermomechanical actuation. Lab Chip 2015;15:2133–9. [DOI] [PubMed] [Google Scholar]
- 57. Dewandre A, Rivero-Rodriguez J, Vitry Y. et al. Microfluidic droplet generation based on non-embedded co-flow-focusing using 3D printed nozzle. Sci Rep 2020;10:21616. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 58. Vladisavljević GT, Al Nuumani R, Nabavi SA.. Microfluidic production of multiple emulsions. Micromachines 2017;8:75. [Google Scholar]
- 59. Shao F, Yu L, Zhang Y. et al. Microfluidic encapsulation of single cells by alginate microgels using a trigger-gellified strategy. Front Bioeng Biotechnol 2020;8:583065. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 60. Okushima S, Nisisako T, Torii T. et al. Controlled production of monodisperse double emulsions by two-step droplet breakup in microfluidic devices. Langmuir 2004;20:9905–8. [DOI] [PubMed] [Google Scholar]
- 61. Terry SC, Jerman JH, Angell JB.. A gas chromatographic air analyzer fabricated on a silicon wafer. IEEE Trans Electron Devices 1979;26:1880–6. [Google Scholar]
- 62. Hwang J, Cho YH, Park MS. et al. Microchannel fabrication on glass materials for microfluidic devices. Int J Precis Eng Manuf 2019;20:479–95. [Google Scholar]
- 63. Malecha K, Maeder T, Jacq C.. Fabrication of membranes and microchannels in low-temperature co-fired ceramic (LTCC) substrate using novel water-based sacrificial carbon pastes. J Eur Ceram Soc 2012;32:3277–86. [Google Scholar]
- 64. Li T. IR transparent ceramic microfluidic chips produced by powder injection molding. RDMS 2021;15(3):000865. [Google Scholar]
- 65. Natarajan G, Humenik JN.. 3D ceramic microfluidic device manufacturing. J Phys: Conf Ser 2006;34:533–9. [Google Scholar]
- 66. Tsao CW. Polymer microfluidics: simple, low-cost fabrication process bridging academic lab research to commercialized production. Micromachines (Basel) 2016;7(12): 225. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 67. Giri K, Tsao CW.. Recent advances in thermoplastic microfluidic bonding. Micromachines (Basel) 2022;13(3):486. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 68. Shakeri A, Jarad NA, Khan S. et al. Bio-functionalization of microfluidic platforms made of thermoplastic materials: a review. Anal Chim Acta 2022;1209:339283. [DOI] [PubMed] [Google Scholar]
- 69. Agha A, Waheed W, Alamoodi N. et al. A review of cyclic olefin copolymer applications in microfluidics and microdevices. Macro Materials Eng 2022;307:2200053. [Google Scholar]
- 70. Nie J, Gao Q, Wang Y. et al. Vessel-on-a-chip with hydrogel-based microfluidics. Small 2018;14:e1802368. [DOI] [PubMed] [Google Scholar]
- 71. Goy CB, Chaile RE, Madrid RE.. Microfluidics and hydrogel: a powerful combination. React Funct Polym 2019;145:104314. [Google Scholar]
- 72. Tolabi H et al. Progress of microfluidic hydrogel-based scaffolds and organ-on-chips for the cartilage tissue engineering. Adv Mater 2023;35:2208852. [DOI] [PubMed] [Google Scholar]
- 73. Yang L, Yu X-Y, Zhu Z. et al. Making a hybrid microfluidic platform compatible for in situ imaging by vacuum-based techniques. J Vac Sci Technol A 2011;29:061101. [Google Scholar]
- 74. Dou M, Dominguez DC, Li X. et al. A versatile PDMS/paper hybrid microfluidic platform for sensitive infectious disease diagnosis. Anal Chem 2014;86:7978–86. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 75. Zhou W, Dou M, Timilsina SS. et al. Recent innovations in cost-effective polymer and paper hybrid microfluidic devices. Lab Chip 2021;21:2658–83. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 76. Li W, Nie Z, Zhang H. et al. Screening of the effect of surface energy of microchannels on microfluidic emulsification. Langmuir 2007;23:8010–4. [DOI] [PubMed] [Google Scholar]
- 77. Alkayyali T, Cameron T, Haltli B. et al. Microfluidic and cross-linking methods for encapsulation of living cells and bacteria - A review. Anal Chim Acta 2019;1053:1–21. [DOI] [PubMed] [Google Scholar]
- 78. Niculescu AG, Chircov C, Bîrcă AC. et al. Fabrication and applications of microfluidic devices: a review. Int J Mol Sci 2021;22:1–26. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 79. Ren K, Zhou J, Wu H.. Materials for microfluidic chip fabrication. ACC Chem Res 2013;46:2396–406. [DOI] [PubMed] [Google Scholar]
- 80. Gale BK, Jafek AR, Lambert CJ. et al. A review of current methods in microfluidic device fabrication and future commercialization prospects. Inventions 2018;3:60. [Google Scholar]
- 81. Yata VK. Principles, materials, and fabrication methods of microfluidics. In: Yata VK (ed.), Microfluidics for Assisted Reproduction in Animals. Singapore: Springer Singapore, 2021, 11–33. [Google Scholar]
- 82. Gomez-Sjoberg R, Leyrat AA, Houseman BT. et al. Biocompatibility and reduced drug absorption of sol-gel-treated poly(dimethyl siloxane) for microfluidic cell culture applications. Anal Chem 2010;82:8954–60. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 83. Toepke MW, Beebe DJ.. PDMS absorption of small molecules and consequences in microfluidic applications. Lab Chip 2006;6:1484–6. [DOI] [PubMed] [Google Scholar]
- 84. Carter S-SD, Atif A-R, Kadekar S. et al. PDMS leaching and its implications for on-chip studies focusing on bone regeneration applications. Organs-on-a-Chip 2020;2:100004. [Google Scholar]
- 85. Rodrigues PM, Xavier M, Calero V. et al. Partitioning of small hydrophobic molecules into polydimethylsiloxane in microfluidic analytical devices. Micromachines (Basel) 2022;13(5):713. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 86. Gökaltun A, Abraham Kang YB, Yarmush ML. et al. Simple surface modification of poly(dimethylsiloxane) via surface segregating smart polymers for biomicrofluidics. Sci Rep 2019;9:7377. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 87. Wang Y, Chen S, Sun H. et al. Recent progresses in microfabricating perfluorinated polymers (Teflons) and the associated new applications in microfluidics. Microphysiol Syst 2018;1:1–1. [Google Scholar]
- 88. Hu YT, Ting Y, Hu JY. et al. Techniques and methods to study functional characteristics of emulsion systems. J Food Drug Anal 2017;25:16–26. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 89. Fingas M, Fieldhouse B.. Water-in-oil emulsions: formation and prediction. In: Fingas M. (Ed.). Handbook of Oil Spill Science and Technology, New Jersey: Wiley, 2015, 225–70. [Google Scholar]
- 90. Zhu Q, Pan Y, Jia X. et al. Review on the stability mechanism and application of water-in-oil emulsions encapsulating various additives. Compr Rev Food Sci Food Saf 2019;18:1660–75. [DOI] [PubMed] [Google Scholar]
- 91. Hong X, Zhao Q, Liu Y. et al. Recent advances on food-grade water-in-oil emulsions: instability mechanism, fabrication, characterization, application, and research trends. Crit Rev Food Sci Nutr 2023;63:1406–36. [DOI] [PubMed] [Google Scholar]
- 92. Shah RK, Shum HC, Rowat AC. et al. Designer emulsions using microfluidics. Materials Today 2008;11:18–27. [Google Scholar]
- 93. Abdulredha MM, Hussain SA, Abdullah LC. et al. Water-in-oil emulsion stability and demulsification via surface-active compounds: a review. J Petroleum Sci Eng 2022;209:109848. [Google Scholar]
- 94. Baret J-C, Baret Surfactants J-C.. Surfactants in droplet-based microfluidics. Lab Chip 2012;12:422–33. [DOI] [PubMed] [Google Scholar]
- 95. Zhang L, Yu Y.. Improving the stability of water-in-oil emulsions with medium internal phase by the introduction of gelatin. Foods 2023;12(15):2863. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 96. Kovalchuk NM, Simmons MJH.. Review of the role of surfactant dynamics in drop microfluidics. Adv Colloid Interface Sci 2023;312:102844. [DOI] [PubMed] [Google Scholar]
- 97. Zembyla M, Murray BS, Sarkar A.. Water-in-oil emulsions stabilized by surfactants, biopolymers and/or particles: a review. Trends Food Sci Technol 2020;104:49–59. [Google Scholar]
- 98. Trivedi V, Ereifej ES, Doshi A. et al. Microfluidic encapsulation of cells in alginate capsules for high throughput screening. In 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, IEEE, September 2009, pp. 7037–40. [DOI] [PubMed]
- 99. Zhang C, Grossier R, Candoni N. et al. Preparation of alginate hydrogel microparticles by gelation introducing cross-linkers using droplet-based microfluidics: a review of methods. Biomater Res 2021;25:41. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 100. Campaña AL, Sotelo DC, Oliva HA. et al. Fabrication and characterization of a low-cost microfluidic system for the manufacture of alginate-lacasse microcapsules. Polymers (Basel) 2020;12(5):1158. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 101. Wang Y, Tan C, Davachi SM. et al. Development of microcapsules using chitosan and alginate via W/O emulsion for the protection of hydrophilic compounds by comparing with hydrogel beads. Int J Biol Macromol 2021;177:92–9. [DOI] [PubMed] [Google Scholar]
- 102. Saeki D, Sugiura S, Kanamori T. et al. Microfluidic preparation of water-in-oil-in-water emulsions with an ultra-thin oil phase layer. Lab Chip 2010;10:357–62. [DOI] [PubMed] [Google Scholar]
- 103. Choi C, Kim J, Nam J. et al. Microfluidic design of complex emulsions. ChemPhysChem 2014;15:21–9. [DOI] [PubMed] [Google Scholar]
- 104. Abate AR, Thiele J, Weitz DA.. One-step formation of multiple emulsions in microfluidics. Lab Chip 2011;11:253–8. [DOI] [PubMed] [Google Scholar]
- 105. Gruner P, Riechers B, Chacòn Orellana LA. et al. Stabilisers for water-in-fluorinated-oil dispersions: key properties for microfluidic applications. Curr Opin Colloid Interface Sci 2015;20:183–91. [Google Scholar]
- 106. Chowdhury MS, Zheng W, Kumari S. et al. Dendronized fluorosurfactant for highly stable water-in-fluorinated oil emulsions with minimal inter-droplet transfer of small molecules. Nat Commun 2019;10:4546. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 107. Laos R, Benner S.. Fluorinated oil-surfactant mixtures with the density of water: artificial cells for synthetic biology. PLoS One 2022;17:e0252361. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 108. Hussain SMS, Adewunmi AA, Mahboob A. et al. Fluorinated surfactants: a review on recent progress on synthesis and oilfield applications. Adv Colloid Interface Sci 2022;303:102634. [DOI] [PubMed] [Google Scholar]
- 109. Niknam SM, Escudero I, Benito JM.. Formulation and preparation ofwater-in-oil-in-water emulsions loaded with a phenolic-rich inner aqueous phase by application of high energy emulsification methods. Foods 2020;9(10):1411. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 110. Jiao Y, Zhao Y, Chang Y. et al. Enhancing the formation and stability of oil-in-water emulsions prepared by microchannels using mixed protein emulsifiers. Front Nutr 2022;9:822053. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 111. Pénicaud C, Landaud S, Jamme F. et al. Physiological and biochemical responses of Yarrowia lipolytica to dehydration induced by air-drying and freezing. PLoS One 2014;9:e111138. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 112. Siedler S, Khatri NK, Zsohár A. et al. Development of a bacterial biosensor for rapid screening of yeast p-Coumaric acid production. ACS Synth Biol 2017;6:1860–9. [DOI] [PubMed] [Google Scholar]
- 113. Best RJ, Lyczakowski JJ, Abalde-Cela S. et al. Label-free analysis and sorting of microalgae and cyanobacteria in microdroplets by intrinsic chlorophyll fluorescence for the identification of fast growing strains. Anal Chem 2016;88:10445–51. [DOI] [PubMed] [Google Scholar]
- 114. Liu H, Xu X, Peng K. et al. Microdroplet enabled cultivation of single yeast cells correlates with bulk growth and reveals subpopulation phenomena. Biotechnol Bioeng 2021;118:647–58. [DOI] [PubMed] [Google Scholar]
- 115. Beneyton T, Thomas S, Griffiths AD. et al. Droplet-based microfluidic high-throughput screening of heterologous enzymes secreted by the yeast Yarrowia lipolytica. Microb Cell Fact 2017;16:18–4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 116. Pan J, Stephenson AL, Kazamia E. et al. Quantitative tracking of the growth of individual algal cells in microdroplet compartments. Integr Biol (Camb) 2011;3:1043–51. [DOI] [PubMed] [Google Scholar]
- 117. Shao F, Yu L, Zhang Y. et al. Microfluidic encapsulation of single cells by alginate microgels using a Trigger-Gellified strategy. Front Bioeng Biotechnol 2020;8:583065. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 118. Nebel S, Lux M, Kuth S. et al. Alginate core–shell capsules for 3D cultivation of adipose-derived mesenchymal stem cells. Bioengineering 2022;9:66. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 119. Łętocha A, Miastkowska M, Sikora E.. Preparation and characteristics of alginate microparticles for food, pharmaceutical and cosmetic applications. Polymers (Basel) 2022;14(18):3834. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 120. McCully AL, Loop Yao M, Brower KK. et al. Double emulsions as a high-throughput enrichment and isolation platform for slower-growing microbes. ISME Commun 2023;3:47. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 121. van Loo B, Heberlein M, Mair P. et al. High-throughput, lysis-free screening for sulfatase activity using Escherichia coli autodisplay in microdroplets. ACS Synth Biol 2019;8:2690–700. [DOI] [PubMed] [Google Scholar]
- 122. Jonáš A, Aas M, Karadag Y. et al. In vitro and in vivo biolasing of fluorescent proteins suspended in liquid microdroplet cavities. Lab Chip 2014;14:3093–100. [DOI] [PubMed] [Google Scholar]
- 123. Luu XC, Shida Y, Suzuki Y. et al. A novel high-throughput approach for transforming filamentous fungi employing a droplet-based microfluidic platform. N Biotechnol 2022;72:149–58. [DOI] [PubMed] [Google Scholar]
- 124. Mohd Isa NS, El Kadri H, Vigolo D. et al. Optimisation of bacterial release from a stable microfluidic-generated water-in-oil-in-water emulsion. RSC Adv 2021;11:7738–49. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 125. Shibai A, Takahashi Y, Ishizawa Y. et al. Mutation accumulation under UV radiation in Escherichia coli. Sci Rep 2017;7:14531. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 126. Snyman M, Huynh TV, Smith MT. et al. The genome-wide rate and spectrum of EMS-induced heritable mutations in the microcrustacean Daphnia: on the prospect of forward genetics. Heredity (Edinb) 2021;127:535–45. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 127. Gou L, Bloom JS, Kruglyak L.. The genetic basis of mutation rate variation in yeast. Genetics 2019;211:731–40. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 128. Li X, Ren JN, Fan G. et al. Genomic and transcriptomic analysis screening key genes for (+)-valencene biotransformation to (+)-nootkatone in Yarrowia lipolytica. Microbiol Res 2022;260:127042. [DOI] [PubMed] [Google Scholar]
- 129.Poisson Distribution for Single Cell Analysis. Dropletex.com. https://dropletex.com/tools-and-resources/?tab=poisson%20distribution%20calculator. (24 April 2024, date last accessed).
- 130. Cox JD, Curry MS, Skirboll SK. et al. Surface passivation of a microfluidic device to glial cell adhesion: a comparison of hydrophobic and hydrophilic SAM coatings. Biomaterials2002; 23(3):929–35. [DOI] [PubMed] [Google Scholar]
- 131.Water in Oil Emulsions. Fluigent.com. https://www.fluigent.com/resources-support/expertise/application-notes/water-in-oil-emulsions/ (26 April 2024, date last accesed).
- 132. Ling SD, Geng Y, Chen A. et al. Enhanced single-cell encapsulation in microfluidic devices: from droplet generation to single-cell analysis. Biomicrofluidics 2020;14:061508. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 133. Silva PTD, Fries LLM, Menezes CRD. et al. Microencapsulation: concepts, mechanisms, methods and some applications in food technology. Cienc Rural 2014;44:1304–11. [Google Scholar]
- 134. Opara EC (ed.). Cell Microencapsulation. In: Methods in Molecular Biology, vol. 1479. New York, NY: Springer New York, 2017. [Google Scholar]
- 135. Su W, Han B, Yeboah S. et al. Fabrication of monodisperse droplets and microcapsules using microfluidic chips: a review of methodologies and applications. Rev Chem Eng 2023;40:401–34. [Google Scholar]
- 136. Collins DJ, Neild A, deMello A. et al. The Poisson distribution and beyond: methods for microfluidic droplet production and single cell encapsulation. Lab Chip 2015;15:3439–59. [DOI] [PubMed] [Google Scholar]
- 137. Tang T, Zhao H, Shen S. et al. Enhancing single-cell encapsulation in droplet microfluidics with fine-tunable on-chip sample enrichment. Microsyst Nanoeng 2024;10:3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 138. Multiphysics C. Introduction to COMSOL multiphysics®, COMSOL Multiphysics, Burlington, MA, vol. 9, 1998, 2018.
- 139.Droplet Size Calculator. Fluigent.com. https://www.fluigent.com/resources-support/support-tools/microfluidic-calculators/droplet-calculator/.(26 April 2024, date last accesed).
- 140.Microfluidic Calculator. Elveflow.com. https://www.elveflow.com/microfluidic-calculator/. (24 April 2024, date last accesed).
- 141.Microfluidic Calculator. Dolomite-Microfluidics.com. https://www.dolomite-microfluidics.com/support/microfluidic-calculator/. (24 April 2024, date last accesed).
- 142.Microfluidic Pressure Drop Calculator. Ufluidix.com. https://www.ufluidix.com/microfluidic-technical-knowledgebase/pressure-drop-calculator/. (25 April 2024, date last accesed)
- 143. Li Y, Fan H, Ding J. et al. Microfluidic devices: the application in TME modeling and the potential in immunotherapy optimization. Front Genet 2022;13:969723. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 144. Xie Z, Pu H, Sun DW.. Computer simulation of submicron fluid flows in microfluidic chips and their applications in food analysis. Compr Rev Food Sci Food Saf 2021;20:3818–37. [DOI] [PubMed] [Google Scholar]
- 145. Sartipzadeh O, Naghib SM, Seyfoori A. et al. Controllable size and form of droplets in microfluidic-assisted devices: effects of channel geometry and fluid velocity on droplet size. Mater Sci Eng C Mater Biol Appl 2020;109:110606. [DOI] [PubMed] [Google Scholar]
- 146. Wacker J, Parashar VK, Gijs MAM.. Influence of oil type and viscosity on droplet size in a flow focusing microfluidic device. Procedia Chem 2009;1:1083–6. [Google Scholar]
- 147. Erb RM, Obrist D, Chen PW. et al. Predicting sizes of droplets made by microfluidic flow-induced dripping. Soft Matter 2011;7:8757–61. [Google Scholar]
- 148. Baker CA, Duong CT, Grimley A. et al. Recent advances in microfluidic detection systems. Bioanalysis 2009;1:967–75. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 149. Zhu Y, Fang Q.. Analytical detection techniques for droplet microfluidics-A review. Anal Chim Acta 2013;787:24–35. [DOI] [PubMed] [Google Scholar]
- 150. Liu WW, Zhu Y.. Development and application of analytical detection techniques for droplet-based microfluidics-A review. Anal Chim Acta 2020;1113:66–84. [DOI] [PubMed] [Google Scholar]
- 151. He Y, Qiao Y, Ding L. et al. Recent advances in droplet sequential monitoring methods for droplet sorting. Biomicrofluidics 2023;17:061501. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 152. Kalantarifard A, Saateh A, Elbuken C.. Label-free sensing in microdroplet-based microfluidic systems. Chemosensors 2018;6:23. [Google Scholar]
- 153. Ibarlucea B, Schütt J, Baraban L. et al. Real-time tracking of individual droplets in multiphase microfluidics. In Karakuş AS (ed.), New Advances in Biosensing. Rijeka: IntechOpen, 2022, 6. [Google Scholar]
- 154. Zhu Y, Fang Q.. Analytical detection techniques for droplet microfluidics-A review. Anal Chim Acta 2013;787:24–35. [DOI] [PubMed] [Google Scholar]
- 155. Liu W, Zhu Y.. Development and application of analytical detection techniques for droplet-based microfluidics-A review. Anal Chim Acta 2020;1113:66–84. [DOI] [PubMed] [Google Scholar]
- 156. Viskari PJ, Landers JP.. Unconventional detection methods for microfluidic devices. Electrophoresis 2006;27:1797–810. [DOI] [PubMed] [Google Scholar]
- 157. Liu H et al. Microdroplet Enabled Cultivation of Single Yeast Cells Correlates with Bulk Growth and Reveals Subpopulation Phenomena. Biotechnol Bioeng2021; (118):647–58. [DOI] [PubMed]
- 158. Li M, Van Zee M, Goda K. et al. Size-based sorting of hydrogel droplets using inertial microfluidics. Lab Chip 2018;18:2575–82. [DOI] [PubMed] [Google Scholar]
- 159. Woronoff G, Nghe P, Baudry J. et al. Metabolic cost of rapid adaptation of single yeast cells contributed new reagents/analytic tools; G. Proc Natl Acad Sci U S A 2020;117:10660–6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 160. Geersens É, Vuilleumier S, Ryckelynck M.. Growth-associated droplet shrinkage for bacterial quantification, growth monitoring, and separation by ultrahigh-throughput microfluidics. ACS Omega 2022;7:12039–47. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 161. Boitard L, Cottinet D, Kleinschmitt C. et al. Monitoring single-cell bioenergetics via the coarsening of emulsion droplets. Proc Natl Acad Sci U S A 2012;109:7181–6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 162. Di Carlo D. Inertial microfluidics. Lab Chip 2009;9:3038–46. [DOI] [PubMed] [Google Scholar]
- 163. Martel JM, Toner M.. Inertial focusing in microfluidics. Annu Rev Biomed Eng 2014;16:371–96. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 164. Gou Y, Jia Y, Wang P. et al. Progress of inertial microfluidics in principle and application. Sensors (Switzerland) 2018;18:1762. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 165. Zhang J, Yan S, Yuan D. et al. Fundamentals and applications of inertial microfluidics: a review. Lab Chip 2016;16:10–34. [DOI] [PubMed] [Google Scholar]
- 166. Kuntaegowdanahalli SS, Bhagat AAS, Kumar G. et al. Inertial microfluidics for continuous particle separation in spiral microchannels. Lab Chip 2009;9:2973–80. [DOI] [PubMed] [Google Scholar]
- 167. Bayareh M. An updated review on particle separation in passive microfluidic devices. Chem Eng Process 2020;153:107984. [Google Scholar]
- 168. Zhang T, Di Carlo D, Lim CT. et al. Passive microfluidic devices for cell separation. Biotechnol Adv 2024;71:108317. [DOI] [PubMed] [Google Scholar]
- 169. Tang H, Niu J, Jin H. et al. Geometric structure design of passive label-free microfluidic systems for biological micro-object separation. Microsyst Nanoeng 2022;8:62. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 170. McGrath J, Jimenez M, Bridle H.. Deterministic lateral displacement for particle separation: a review. Lab Chip 2014;14:4139–58. [DOI] [PubMed] [Google Scholar]
- 171. Salafi T, Zhang Y, Zhang Y.. A review on deterministic lateral displacement for particle separation and detection. Nanomicro Lett 2019;11:77. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 172. Joensson HN, Uhlén M, Svahn HA.. Droplet size based separation by deterministic lateral displacement- separating droplets by cell-induced shrinking. Lab Chip 2011;11:1305–10. [DOI] [PubMed] [Google Scholar]
- 173. Zhang T, Cain AK, Semenec L. et al. Microfluidic separation and enrichment of Escherichia coli by size using viscoelastic flows. Anal Chem 2023;95:2561–9. [DOI] [PubMed] [Google Scholar]
- 174. Zhbanov A, Lee YS, Yang S.. Current status and further development of deterministic lateral displacement for micro-particle separation. Micro and Nano Syst Lett 2023;11(1):11. [Google Scholar]
- 175. Hochstetter A, Vernekar R, Austin RH. et al. Deterministic lateral displacement: challenges and perspectives. ACS Nano 2020;14:10784–95. [DOI] [PubMed] [Google Scholar]
- 176. Woronoff G, Nghe P, Baudry J. et al. Metabolic cost of rapid adaptation of single yeast cells contributed new reagents/analytic tools; G. Proc Natl Acad Sci U S A 2020;117:10660–6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 177. Song Y, Li D, Xuan X.. Recent advances in multimode microfluidic separation of particles and cells. Electrophoresis 2023;44:910–37. [DOI] [PubMed] [Google Scholar]
- 178. Wang X, Papautsky I.. Size-based microfluidic multimodal microparticle sorter. Lab Chip 2015;15:1350–9. [DOI] [PubMed] [Google Scholar]
- 179. Zhou J, Papautsky I.. Viscoelastic microfluidics: progress and challanges. Microsys Nanoengineering 2020;6(1):113. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 180. Warkiani ME, Tay AKP, Guan G. et al. Membrane-less microfiltration using inertial microfluidics. Sci Rep 2015;5:11018. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 181. Mogensen KB, Kutter JP.. Optical detection in microfluidic systems. Electrophoresis 2009;30 (Suppl 1):S92–100. [DOI] [PubMed] [Google Scholar]
- 182. Kuswandi B, Huskens J, Verboom W. et al. Optical sensing systems for microfluidic devices: a review. Anal Chim Acta 2007;601:141–55. [DOI] [PubMed] [Google Scholar]
- 183. Hengoju S, Shvydkiv O, Tovar M. et al. Advantages of optical fibers for facile and enhanced detection in droplet microfluidics. Biosens Bioelectron 2022;200:113910. [DOI] [PubMed] [Google Scholar]
- 184. Yang T, Stavrakis S, DeMello A.. A high-sensitivity, integrated absorbance and fluorescence detection scheme for probing picoliter-volume droplets in segmented flows. Anal Chem 2017;89:12880–7. [DOI] [PubMed] [Google Scholar]
- 185. McKinnon KM. Flow cytometry: an overview. Curr Protoc Immunol 2018;120:5.1.1–5.1.11. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 186. Maciorowski Z, Chattopadhyay PK, Jain P.. Basic multicolor flow cytometry. Curr Protoc Immunol 2017;117:5.4.1–5.4.38. [DOI] [PubMed] [Google Scholar]
- 187. Holmberg-Thyden S, Grønbæk K, Gang AO. et al. A user’s guide to multicolor flow cytometry panels for comprehensive immune profiling. Anal Biochem 2021;627:114210. [DOI] [PubMed] [Google Scholar]
- 188. Baret J-C, Miller OJ, Taly V. et al. Fluorescence-activated droplet sorting (FADS): efficient microfluidic cell sorting based on enzymatic activity. Lab Chip 2009;9:1850–8. [DOI] [PubMed] [Google Scholar]
- 189. Qiao Y, Zhao X, Zhu J. et al. Fluorescence-activated droplet sorting of lipolytic microorganisms using a compact optical system. Lab Chip 2018;18:190–6. [DOI] [PubMed] [Google Scholar]
- 190. Vallejo D, Nikoomanzar A, Paegel BM. et al. Fluorescence-activated droplet sorting for single-cell directed evolution. ACS Synth Biol 2019;8:1430–40. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 191. Fu JL, Fang Q, Zhang T. et al. Laser-induced fluorescence detection system for microfluidic chips based on an orthogonal optical arrangement. Anal Chem 2006;78:3827–34. [DOI] [PubMed] [Google Scholar]
- 192. An G-H, Bielich J, Auerbach R. et al. Isolation and characterization of carotenoid hyperproducing mutants of yeast by flow cytometry and cell sorting. Biotechnology (N Y) 1991;9:70–3. [DOI] [PubMed] [Google Scholar]
- 193. Ukibe K, Katsuragi T, Tani Y. et al. Efficient screening for astaxanthin-overproducing mutants of the yeast Xanthophyllomyces dendrorhous by flow cytometry. FEMS Microbiol Lett 2008;286:241–8. [DOI] [PubMed] [Google Scholar]
- 194. Tao Z, Wang G, Xu X. et al. Monitoring and rapid quantification of total carotenoids in Rhodotorula glutinis cells using laser tweezers Raman spectroscopy. FEMS Microbiol Lett 2011;314:42–8. [DOI] [PubMed] [Google Scholar]
- 195. Chan JW. Recent advances in laser tweezers Raman spectroscopy (LTRS) for label-free analysis of single cells. J Biophotonics 2013;6:36–48. [DOI] [PubMed] [Google Scholar]
- 196. Abalde-Cela S, Gould A, Liu X. et al. High-throughput detection of ethanol-producing cyanobacteria in a microdroplet platform. J R Soc Interface 2015;12. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 197. Stoytcheva M, Montero G, Zlatev R. et al. Analytical methods for lipases activity determination: a review. CAC 2012;8:400–7. [Google Scholar]
- 198. Najah M, Calbrix R, Mahendra-Wijaya IP. et al. Droplet-based microfluidics platform for ultra-high-throughput bioprospecting of cellulolytic microorganisms. Chem Biol 2014;21:1722–32. [DOI] [PubMed] [Google Scholar]
- 199. Li S, Zhang Y, Li L. et al. Establishment of picodroplet-based co-culture system to improve erythritol production in Yarrowia lipolytica. Biochem Eng J 2023;198:109036. [Google Scholar]
- 200. Choi W, Yu C-C, Fang-Yen C. et al. Field-based angle-resolved light-scattering study of single live cells. Opt Lett 2008;33:1596–8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 201. Pacocha N, Bogusławski J, Horka M. et al. High-throughput monitoring of bacterial cell density in nanoliter droplets: label-free detection of unmodified gram-positive and gram-negative bacteria. Anal Chem 2021;93:843–50. [DOI] [PubMed] [Google Scholar]
- 202. Liang L, Liang M, Zuo Z. et al. Label-free single-cell analysis in microdroplets using a light-scattering-based optofluidic chip. Biosens Bioelectron 2024;253:116148. [DOI] [PubMed] [Google Scholar]
- 203. Nitta N, Sugimura T, Isozaki A. et al. Intelligent image-activated cell sorting. Cell 2018;175:266–76.e13. [DOI] [PubMed] [Google Scholar]
- 204. Sesen M, Whyte G.. Image-based single cell sorting automation in droplet microfluidics. Sci Rep 2020;10:8736. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 205. Rutkowski GP, Azizov I, Unmann E. et al. Microfluidic droplet detection via region-based and single-pass convolutional neural networks with comparison to conventional image analysis methodologies. Mach Learn App 2022;7:100222. [Google Scholar]
- 206. Tang T, Zhao H, Shen S. et al. Enhancing single-cell encapsulation in droplet microfluidics with fine-tunable on-chip sample enrichment. Microsyst Nanoeng 2024;10:3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 207. Yang D, Yu Z, Zheng M. et al. Artificial intelligence-accelerated high-throughput screening of antibiotic combinations on a microfluidic combinatorial droplet system. Lab Chip 2023;23:3961–77. [DOI] [PubMed] [Google Scholar]
- 208. Isozaki A, Mikami H, Hiramatsu K. et al. A practical guide to intelligent image-activated cell sorting. Nat Protoc 2019;14:2370–415. [DOI] [PubMed] [Google Scholar]
- 209. Pan J, Stephenson AL, Kazamia E. et al. Quantitative tracking of the growth of individual algal cells in microdroplet compartments. Integr Biol (Camb) 2011;3:1043–51. [DOI] [PubMed] [Google Scholar]
- 210. Taylor D, Verdon N, Lomax P. et al. Tracking the stochastic growth of bacterial populations in microfluidic droplets. Phys Biol 2022;19:026003. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 211. Sun T, Morgan H.. Single-cell microfluidic impedance cytometry: a review. Microfluid Nanofluid 2010;8:423–43. [Google Scholar]
- 212. Kubra Isgor P, Marcali M, Keser M. et al. Microfluidic droplet content detection using integrated capacitive sensors. Sens Actuators B Chem 2015;210:669–75. [Google Scholar]
- 213. Zhong J, Liang M, Tang Q. et al. Selectable encapsulated cell quantity in droplets via label-free electrical screening and impedance-activated sorting. Mater Today Bio 2023;19:100594. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 214. Chen YS, Huang CH, Pai PC. et al. A review on microfluidics-based impedance biosensors. Biosensors 2023;13(1):83. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 215. Daniels JS, Pourmand N.. Label‐Free impedance biosensors: opportunities and challenges. Electroanalysis 2007;19:1239–57. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 216. Kemna EWM, Segerink LI, Wolbers F. et al. Label-free, high-throughput, electrical detection of cells in droplets. Analyst 2013;138:4585–92. [DOI] [PubMed] [Google Scholar]
- 217. Gencoglu A, Minerick AR.. Electrochemical detection techniques in micro- and nanofluidic devices. Microfluid Nanofluid 2014;17:781–807. [Google Scholar]
- 218. Mazzoleni AP, Sisken BF, Kahler RL.. Conductivity values of tissue culture medium from 20°C to 40°C. Bioelectromagnetics 1986;7:95–9. [DOI] [PubMed] [Google Scholar]
- 219. Civelekoglu O, Liu R, Asmare N. et al. Wrap-around sensors for electrical detection of particles in microfluidic channels. Sens Actuators B Chem 2023;375:132874. [Google Scholar]
- 220. Huang C, Jiang Y, Li Y. et al. Droplet detection and sorting system in microfluidics: a review. Micromachines 2023;14(1):103. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 221. Riffo B, Henríquez C, Chávez R. et al. Nonionizing electromagnetic field: a promising alternative for growing control yeast. JoF 2021;7:281. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 222. Hulsheger H, Potel J, Niemann E-G.. Electric field effects on bacteria and yeast cells. Radiat Environ Biophys 1983;22:149–62. [DOI] [PubMed] [Google Scholar]
- 223. Zhou B, Wang C, Xiao X. et al. Controllable microdroplet splitting via additional lateral flow and its application in rapid synthesis of multi-scale microspheres. RSC Adv 2015;5:10365–71. [Google Scholar]
- 224. Tenje M, Fornell A, Ohlin M. et al. Particle manipulation methods in droplet microfluidics. Anal Chem 2018;90:1434–43. [DOI] [PubMed] [Google Scholar]
- 225. Han SI, Soo Kim H, Han A.. In-droplet cell concentration using dielectrophoresis. Biosens Bioelectron 2017;97:41–5. [DOI] [PubMed] [Google Scholar]
- 226. Fornell A, Cushing K, Nilsson J. et al. Binary particle separation in droplet microfluidics using acoustophoresis. Appl Phys Lett 2018;112:063701. [Google Scholar]
- 227. Han SI, Huang C, Han A.. In-droplet cell separation based on bipolar dielectrophoretic response to facilitate cellular droplet assays. Lab Chip 2020;20:3832–41. [DOI] [PubMed] [Google Scholar]
- 228. Gerlt MS, Haidas D, Ratschat A. et al. Manipulation of single cells inside nanoliter water droplets using acoustic forces. Biomicrofluidics 2020;14:064112. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 229. Zhang W, Li N, Lin L. et al. Concentrating single cells in picoliter droplets for phospholipid profiling on a microfluidic system. Small 2020;16:e1903402. [DOI] [PubMed] [Google Scholar]
- 230. Cruz FJ, Zadeh SH, Wu ZG. et al. Inertial focusing of microparticles and its limitations. J Phys: Conf Ser 2016;757:012028. [Google Scholar]
- 231. Nam J, Lim H, Kim C. et al. Density-dependent separation of encapsulated cells in a microfluidic channel by using a standing surface acoustic wave. Biomicrofluidics 2012;6:24120. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 232. Sun G, Qu L, Azi F. et al. Recent progress in high-throughput droplet screening and sorting for bioanalysis. Biosens Bioelectron 2023;225:115107. [DOI] [PubMed] [Google Scholar]
- 233. Wu M, Ozcelik A, Rufo J. et al. Acoustofluidic separation of cells and particles. Microsyst Nanoeng 2019;5:32. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 234. Ding X, Li P, Lin S-CS. et al. Surface acoustic wave microfluidics. Lab Chip 2013;13:3626–49. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 235. Han J, Hu H, Lei Y. et al. Optimization analysis of particle separation parameters for a standing surface acoustic wave Acoustofluidic chip. ACS Omega 2022;8:311–23. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 236. Leibacher I, Reichert P, Dual J.. Microfluidic droplet handling by bulk acoustic wave (BAW) acoustophoresis. Lab Chip 2015;15:2896–905. [DOI] [PubMed] [Google Scholar]
- 237. Destgeer G, Ha BH, Park J. et al. Travelling surface acoustic waves microfluidics. Physics Procedia 2015;70:34–7. [Google Scholar]
- 238. Shi J, Huang H, Stratton Z. et al. Continuous particle separation in a microfluidic channel via standing surface acoustic waves (SSAW). Lab Chip 2009;9:3354–9. [DOI] [PubMed] [Google Scholar]
- 239. Zhong R, Yang S, Ugolini GS. et al. Acoustofluidic droplet sorter based on single phase focused transducers. Small 2021;17:e2103848. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 240. Fan Y, Wang X, Ren J. et al. Recent advances in acoustofluidic separation technology in biology. Microsyst Nanoeng 2022;8:94. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 241. Salafi T, Zeming KK, Zhang Y.. Advancements in microfluidics for nanoparticle separation. Lab Chip 2017;17:11–33. [DOI] [PubMed] [Google Scholar]
- 242. Choe SW, Kim B, Kim M.. Progress of microfluidic continuous separation techniques for micro-/nanoscale bioparticles. Biosensors 2021;11(11):464. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 243. Lenshof A, Laurell T.. Continuous separation of cells and particles in microfluidic systems. Chem Soc Rev 2010;39:1203–17. [DOI] [PubMed] [Google Scholar]
- 244. Zhang S, Wang Y, Onck P. et al. A concise review of microfluidic particle manipulation methods. Microfluid Nanofluid 2020;24:24. [Google Scholar]
- 245. Grover WH, Ivester RHC, Jensen EC. et al. Development and multiplexed control of latching pneumatic valves using microfluidic logical structures. Lab Chip 2006;6:623–31. [DOI] [PubMed] [Google Scholar]
- 246. Cao Z, Chen F, Bao N. et al. Droplet sorting based on the number of encapsulated particles using a solenoid valve. Lab Chip 2013;13:171–8. [DOI] [PubMed] [Google Scholar]
- 247.Microfluidic Chip Cell Sorter: On-chip® Sort. On-chipbio.com. https://on-chipbio.com/product-onchip_sort/. (26 April 2024, date last accesed).
- 248. Utharala R, Tseng Q, Furlong EEM. et al. A versatile, low-cost, multiway microfluidic sorter for droplets, cells, and embryos. Anal Chem 2018;90:5982–8. [DOI] [PubMed] [Google Scholar]
- 249. Zhang H, Chang H, Neuzil P.. DEP-on-a-chip: dielectrophoresis applied to microfluidic platforms. Micromachines (Basel) 2019;10(6):423. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 250. Pesch GR, Du F.. A review of dielectrophoretic separation and classification of non-biological particles. Electrophoresis 2021;42:134–52. [DOI] [PubMed] [Google Scholar]
- 251. Çetin B, Li D.. Dielectrophoresis in microfluidics technology. Electrophoresis 2011;32:2410–27. [DOI] [PubMed] [Google Scholar]
- 252. Kwizera EA, Sun M, White AM. et al. Methods of generating dielectrophoretic force for microfluidic manipulation of bioparticles. ACS Biomater Sci Eng 2021;7:2043–63. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 253. Li M, Li WH, Zhang J. et al. A review of microfabrication techniques and dielectrophoretic microdevices for particle manipulation and separation. J Phys D: Appl Phys 2014;47:063001. [Google Scholar]
- 254. Isozaki A, Nakagawa Y, Loo MH. et al. Sequentially addressable dielectrophoretic array for high-throughput sorting of large-volume biological compartments. Sci Adv 2020;6:eaba6712. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 255. Chaudhuri J, Timung S, Dandamudi CB. et al. Discrete electric field mediated droplet splitting in microchannels: fission, Cascade, and Rayleigh modes. Electrophoresis 2017;38:278–86. [DOI] [PubMed] [Google Scholar]
- 256. Fallah K, Fattahi E.. Splitting of droplet with different sizes inside a symmetric T-junction microchannel using an electric field. Sci Rep 2022;12:3226. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 257. Sciambi A, Abate AR.. Accurate microfluidic sorting of droplets at 30 kHz. Lab Chip 2015;15:47–51. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 258. Clark IC, Thakur R, Abate AR.. Concentric electrodes improve microfluidic droplet sorting. Lab Chip 2018;18:710–3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 259. Loo MH, Nakagawa Y, Kim SH. et al. High-throughput sorting of nanoliter droplets enabled by a sequentially addressable dielectrophoretic array. Electrophoresis 2022;43:477–86. [DOI] [PubMed] [Google Scholar]
- 260. Qin X, Li L, Jiang Z. et al. Acoustic valve for droplet microfluidics. In 2021 IEEE 34th International Conference on Micro Electro Mechanical Systems (MEMS), IEEE, January 2021, 176–9.
- 261. Zhang Q, Wang T, Zhou Q. et al. Development of a facile droplet-based single-cell isolation platform for cultivation and genomic analysis in microorganisms. Sci Rep 2017;7:41192. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 262. Watterson WJ, Tanyeri M, Watson AR. et al. Droplet-based high-throughput cultivation for accurate screening of antibiotic resistant gut microbes. Elife 2020;9:1–22. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 263. Morbioli GG, Speller NC, Cato ME. et al. An automated low-cost modular hardware and software platform for versatile programmable microfluidic device testing and development. Sens Actuators B Chem 2021;346:130538. [Google Scholar]
- 264. Gao RZ, Hébert M, Huissoon J. et al. µPump: An open-source pressure pump for precision fluid handling in microfluidics. HardwareX 2020;7:e00096. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 265. Liu J, Marquez M, Lai Y. et al. Swept coded aperture real-time femtophotography. Nat Commun 2024;15:1589. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 266.TMX 5010. https://www.phantomhighspeed.com/products/cameras/tmx/5010. (24 June 2024, date last accesed).
- 267. Ho BD, Beech JP, Tegenfeldt JO.. Cell sorting using electrokinetic deterministic lateral displacement. Micromachines (Basel) 2021;12:1–14. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 268. Church C, Zhu J, Xuan X.. Negative dielectrophoresis-based particle separation by size in a serpentine microchannel. Electrophoresis 2011;32:527–31. [DOI] [PubMed] [Google Scholar]
- 269. Beech JP, Jönsson P, Tegenfeldt JO.. Tipping the balance of deterministic lateral displacement devices using dielectrophoresis. Lab Chip 2009;9:2698–706. [DOI] [PubMed] [Google Scholar]
- 270. Calero V, García-Sánchez P, Ramos A. et al. Electrokinetic biased deterministic lateral displacement: scaling analysis and simulations. J Chromatogr A 2020;1623:461151. [DOI] [PubMed] [Google Scholar]
- 271. Yiannacou K, Sariola V.. Controlled manipulation and active sorting of particles inside microfluidic chips using bulk acoustic waves and machine learning. Langmuir 2021;37:4192–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 272. Talebjedi B, Heydari M, Taatizadeh E. et al. Neural network-based optimization of an acousto microfluidic system for submicron bioparticle separation. Front Bioeng Biotechnol 2022;10:878398. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 273. Tsai HF, Podder S, Chen PY.. Microsystem advances through integration with artificial intelligence. Micromachines (Basel) 2023;14(4):826. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 274.Goda K., Lu H., Fei P., Guck J., the Lab on a Chip Editorial Office. AI in Microfluidics. pubs.rsc.org. https://pubs.rsc.org/en/journals/articlecollectionlanding?sercode=lc&themeid=0f660287-aa27- 472b-b529-14080dd86861. (24 June 2024, date last accessed).
- 275. Liu H, Nan L, Chen F. et al. Functions and applications of artificial intelligence in droplet microfluidics. Lab Chip 2023;23:2497–513. [DOI] [PubMed] [Google Scholar]
- 276.Oransky I., Marcus A. Thousands of Studies Used The Wrong Cells, And Journals Are Doing Nothing. (published July 21, 2016). https://www.statnews.com/2016/07/21/studies-wrong-cells/. (24 June 2024, date last accesed).
- 277. Freedman LP, Cockburn IM, Simcoe TS.. The economics of reproducibility in preclinical research. PLoS Biol 2015;13:e1002165. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 278.End Cross-Contamination in Flow Cytometry through Microfluidics. (published 18 May 2021). https://www.phchd.com/apac/biomedical/service-downloads/evolving-science-for-the-future/end-cross-contamination. (24 June 2024, date last accesed).
- 279. Vahey MD, Quiros Pesudo L, Svensson JP. et al. Microfluidic genome-wide profiling of intrinsic electrical properties in Saccharomyces cerevisiae. Lab Chip 2013;13:2754–63. [DOI] [PMC free article] [PubMed] [Google Scholar]














