Authors’ reply to “Left atrial strain: an operator and software-dependent tool”

Marta Cicetti 1,2,#, François Bagate 1,3,✉,#, Cristina Lapenta 1, Ségolène Gendreau 1,3, Paul Masi 1,3, Armand Mekontso Dessap 1,3,4
PMCID: PMC11329439  PMID: 39152307

Dear Editor,

We thank Beyls and colleagues for their interest in our recent article on left atrial strain (LAS) [1]. They stated that our sample size calculation, based on a predicted 5% increase in the LAS reservoir (LASr), might be underestimated given that the repeatability and reliability of the LAS measurement is unknown. As stated in the Methods section of our paper, we attempted to minimise measurement inconsistencies. First, we used Automated Function Imaging (AFI) left atrial software (EchoPAC, GE Healthcare), which follows the 2018 EACVI-ASE Strain Standardised Task Force guidelines [2]. Second, we performed LAS analysis according to the cited recommendations [2], including measurement of left atrial strain in both four-chamber and two-chamber apical views. The same methodology has been used in large studies that have helped to define reference values for LAS [3]. Third, we assessed intra-observer variability in 10 randomly selected subjects using the interclass correlation coefficient (ICC), a measure of repeatability according to the study by Bunting et al. [4]. In our cohort, intra-observer analysis showed good repeatability of the three components of left atrial strain: LASr (ICC = 0.92), LAS conduit (LAScd) (ICC = 0.81), LAS contraction (LASct) (ICC = 0.95). Finally, we performed intra- and inter-observer variability analysis according to the methods of previous studies, including the paper by Beyls et al. [5], which investigated LAS as a predictive marker of atrial fibrillation (AF) in patients with COVID-19 pneumonia.

Beyls et al. mentioned that the value of the LASr we identified for sample size calculation was derived from previous studies using different software for LAS analysis and that there is some evidence of inter-vendor variability in strain measurements. They cited the study by Wang et al. [6] comparing EchoPAC version 201 (GE Vingmed Ultrasound) and Image Arena 2D Cardiac Performance Analysis version 4.6 (TomTec Imaging Systems, Unterschleissheim, Germany). However, in the paper by Wang et al. [6], the EchoPAC system used the LV strain package to assess LAS, as did many other studies prior to the commercialisation of the AFI left atrial software. To our knowledge, there are no published studies comparing EchoPAC AFI left atrial and TomTec.

The authors correctly mentioned that assessing fluid responsiveness by Left Ventricular Outflow Tract – Velocity Time Integral (LVOT – VTI) variation may have led to misclassification of patients. We agree that this is a limitation of our work and have already discussed this in the Limitations section of the article. The observational nature of our study necessitated the use of echocardiography to estimate cardiac output, as haemodynamic monitoring is routinely performed by echocardiography in our ICU. Regarding the observed improvement in haemodynamics in the non-responder group, although the increase in arterial pressure during volume expansion was statistically significant, its clinical relevance is questionable.

The authors highlight that we studied a heterogeneous cohort of patients with varying degrees of pre-existing left atrial dysfunction prior to ICU admission; this may have influenced the LAS response to fluid administration. We agree that cardiac comorbidities may affect atrial function in the acute setting and influence treatment response. However, it is difficult to investigate the contribution of pre-admission pathology because baseline echocardiography is not always available and rarely includes left atrial strain measurement. We tested the two groups (fluid responders and non-responders) for differences in comorbidities and there was no significant difference (unpublished). From a pragmatic perspective, as chronic cardiovascular disease is common in critically ill patients, we believe that our cohort reflects the routine practice ICU population.

In conclusion, we agree that further studies are needed to investigate the usefulness of LAS in critically ill patients.

Acknowledgements

Not applicable.

Abbreviations

LAS

Left Atrial Strain

LASr

Left Atrial Strain reservoir

AFI

Automated Function Imaging

EACVI

European Association of CadioVascular Imaging

ASE

American Society of Echocardiography

LAScd

LAS conduit

LASct

LAS contraction

AF

Atrial Fibrillation

LVOT – VTI

Left Ventricular Outflow Tract – Velocity Time Integral

ICU

Intensive Care Unit

Author Contributions

MC and FB has drafted the work, and FB, CL, SG, PM and AMD have substantively revised it. All authors read and approved the final manuscript.

Funding

Not applicable.

Data availability

Not applicable.

Declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Footnotes

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Marta Cicetti and François Bagate contributed equally to this work

References

  • 1.Cicetti M, Bagate F, Lapenta C, Gendreau S, Masi P, Mekontso Dessap A. Effect of volume infusion on left atrial strain in acute circulatory failure. Ann Intensive Care. 2024;14(1):53. 10.1186/s13613-024-01274-6. PMID: 38592568; PMCID: PMC11003961. 10.1186/s13613-024-01274-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Badano LP, Kolias TJ, Muraru D, Abraham TP, Aurigemma G, Edvardsen T, D’Hooge J, Donal E, Fraser AG, Marwick T, Mertens L, Popescu BA, Sengupta PP, Lancellotti P, Thomas JD, Voigt JU. Industry representatives; Reviewers: This document was reviewed by members of the 2016–2018 EACVI Scientific Documents Committee. Standardization of left atrial, right ventricular, and right atrial deformation imaging using two-dimensional speckle tracking echocardiography: a consensus document of the EACVI/ASE/Industry Task Force to standardize deformation imaging. Eur Heart J Cardiovasc Imaging. 2018;19(6):591–600. 10.1093/ehjci/jey042. Erratum in: Eur Heart J Cardiovasc Imaging. 2018;19(7):830–833. PMID: 29596561. [DOI] [PubMed]
  • 3.Tadafumi Sugimoto S, Robinet R, Dulgheru, et al. Echocardiographic reference ranges for normal left atrial function parameters: results from the EACVI NORRE study. Eur Heart J - Cardiovasc Imaging. 2018;19:630–8. 10.1093/ehjci/jey018. 10.1093/ehjci/jey018 [DOI] [PubMed] [Google Scholar]
  • 4.Bunting KV, Steeds RP, Slater K, Rogers JK, Gkoutos GV, Kotecha D. A practical guide to assess the reproducibility of echocardiographic measurements. J Am Soc Echocardiogr. 2019;32(12):1505–15. Epub 2019 Oct 22. PMID: 31653530. 10.1016/j.echo.2019.08.015 [DOI] [PubMed] [Google Scholar]
  • 5.Beyls C, Hermida A, Bohbot Y, et al. Automated left atrial strain analysis for predicting atrial fibrillation in severe COVID-19 pneumonia: a prospective study. Ann Intensive Care. 2021;11:168. 10.1186/s13613-021-00955-w. 10.1186/s13613-021-00955-w [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Wang Y, Li Z, Fei H, et al. Left atrial strain reproducibility using vendor-dependent and vendor-independent software. Cardiovasc Ultrasound. 2019;17:9. 10.1186/s12947-019-0158-y. 10.1186/s12947-019-0158-y [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

Not applicable.


Articles from Annals of Intensive Care are provided here courtesy of Elsevier

RESOURCES