Abstract
Objective
To evaluate the variation in the area estimation under different mathematical calculations against measurement by a smartphone application in estimating the cutaneous wound areas in captive Asian elephants.
Methods
The study was conducted on captive Asian elephants (Elephas maximus) with cutaneous wounds reported to Veterinary Hospitals of Kerala Veterinary and Animal Sciences University and elephant camps within and outside Kerala state (mostly southern states of India, namely, Kerala and Tamil Nadu) over the period September 2019 to October 2022. Thirty-five clinical cases diagnosed with skin wounds of different aetiologies at various parts of the body were subjected to measurement, and 111 measurements were taken using a smartphone application, Imito Measure (Imito AG, Zurich, Switzerland). Based on the outer wound perimeters hand-marked on the mobile screen over the image taken, Imito Measure calculated the length, width, perimeter, and area. The length and width measurements from this were applied to four mathematical models of wound measurements. Wound surface area calculations were further done by these models and were compared.
Results
The observed results indicated no significant difference between the five methods of area measurement in all the studied cases since the P > 0.05.
Conclusion
The findings revealed no significant difference between the five techniques of wound area measurement. From the practical clinical utility point, the smartphone application has an edge over the mathematical methods in animals, especially captive Asian elephants, as it has the major advantage of being non-contact and thus addresses some major welfare concerns.
Keywords: non-contact measurements, animal welfare, captive asian elephants, mobile applications, smartphones, digital planimetry, wound measurements, skin injuries
Introduction
As the skin provides primary protection, the cutaneous wounds resulting from external violence are a common problem in elephants. The occurrence of cutaneous wounds in captive Asian elephants was previously recorded at 44% in Sri Lanka [1], 19.1% and 21.2% in two centers in Thailand [2], and 6.9% in North America [3]. In India, studies reported 16% [4], 39.72%, and 38.64% in two places [5]. In the past few years, numerous methods for assessing the area and volume of wounds have been published in the literature. Assessment methods must be accurate, reliable, and practical when analyzing treatment regimens in clinical work and research investigations. The delineation of the wound border, which is sometimes challenging to figure out, is one of the elements influencing wound measuring accuracy. Small motions can alter the look of a wound, and location on a curved area of the body can make estimating wound size difficult. Some wounds are also severely damaged, making it impossible to determine the volume. Lastly, wounds in places with thick soft tissue covering might produce complications due to physiological contraction [6].
Traditionally, wound measuring methodologies have relied on two-dimensional approaches. The ruler approach sometimes overestimates the wound size and could be more effective in big wounds with uneven borders, yet it is quick, simple, and affordable. The elliptical approach is simple and economical and may be used to measure ellipse-shaped wounds [7,8].
The planimetric approach is simple to master and an accurate and dependable method that considers body curvature [9]. Although digital planimetry is marginally more precise and reliable than manual planimetry, both approaches entail contact with the wound and thus pose the danger of wound contamination [10]. Manual planimetry is time-consuming because it involves the precise marking of wound edges onto the tracing sheet and determining the traced area by manually counting 1 mm2 in that area. Compared to the planimetric technique, the digital imaging method is similarly precise and trustworthy, and it is a non-contact approach, eliminating the possibility of wound contamination and pain during handling, a significant welfare concern in the case of animals [11].
The present study aims to evaluate the variation in the area estimation by different mathematical calculations against measurement by the smartphone application.
Materials and methods
The study was conducted on captive Asian elephants (Elephas maximus) with cutaneous wounds reported to Veterinary Hospitals of Kerala Veterinary and Animal Sciences University and elephant camps within and outside Kerala state (mostly southern states of India, namely, Kerala and Tamil Nadu) over the period September 2019 to October 2022 after obtaining the necessary permissions from the concerned owner/authority before the commencement of the study.
All animals, irrespective of age and sex, that presented to the surgery outpatient unit were screened for the evaluation of wounds. Clinical cases belonging to private owners were attended to, followed by a request from the owner/custodian or after obtaining informed consent from the concerned person/authority.
Thirty-five clinical cases diagnosed with skin wounds of various etiologies were subjected to measurement, and 111 measurements were taken. The measurements such as length, width, area, and perimeter were determined using the mobile application, and wound images were taken.
Wound measurement by a smartphone application
The smartphone application ImitoMeasure (Imito AG, Zurich, Switzerland) was downloaded for free from the Google Play store to an Android smartphone, Samsung S-20 FE 5G (model: SM-G781B/DS). The calibrated marker for wound assessment comparison was received as a PDF file from the application's developers. The markers were printed onto 220 GSM paper, which was cut individually for use and disposal. To avoid inter-operator variations (variations between operators who may have different perceptions regarding the wound margin and variation in the level of expertise in using the mobile application), only one person measured the wound using this mobile application. The same phone was used throughout the study period to avoid device errors. The routine smartphone application and system updates were done during the entire study period.
Wound length, width, surface area, and perimeter measurement
After the debridement, wound lavage, and cleaning of the area, the calibrated marker was placed near the wound. The smartphone application, ImitoMeausre, was opened, and the smartphone's camera was aimed at the wound. The camera was aligned with a calibrated marker so that the camera detected the marker and allowed capture. The aligning was noted by the appearance of a green square around the calibrated marker and a message saying “marker detected” on the screen. The image of the wound was captured by clicking the " capture " button on the screen in the top left corner. Once the image was obtained, the wound perimeter was marked with a finger on the smartphone's screen. The markings appeared as green lines with dots on them. The drawings are completed by joining the end to its origin-the measurements are obtained by clicking the “measure” button on the screen. The result screen was with an image of the wound and its measurements. The wound length and width were green dotted lines with the lengthiest and widest widths. The application automatically calculates the wound surface area and perimeter when clicking the “measure” button.
Wound surface area calculation by other methods
Method (1): The exact length and width measurements of wounds calculated by the application were used for wound surface area calculations by mathematical methods (n=111) to avoid direct contact with a wound surface.
Method (2): A standard simple ruler method of wound surface area estimation for rectangular was done by multiplying the longest length by the widest width. In this method, the wound shape is considered as rectangular [12].
Method (3): A mathematical method of wound surface area estimation for ellipse was done by multiplying the longest length by the widest width with a factor of 0.785 or π/4. In this method, the wound shape is considered an ellipse [2].
Method (4): A mathematical method of wound surface area estimation optimized for human plantar ulcers was done by multiplying the longest length by the widest width with a factor of 0.73 [13].
Method (5): A mathematical method of wound surface area estimation optimized for venous ulcers in humans was done by multiplying the longest length by the widest width with a factor of 0.67 [13]. After this, the values are sorted as values with orthogonal length and width measurements (n=66) and values without orthogonal length and width measurements (non-orthogonal) (n=45).
Method (6): The calculations were done for orthogonal (n=66) as per the following formula [13]:
(1) standard ruler method = longest length X orthogonal widest width
(2) ellipse = longest length X orthogonal widest width X 0.785
(3) optimized (p) = longest length X orthogonal widest width X 0.73
(4) optimized (v) = longest length X orthogonal widest width X 0.67
The calculations are done for non-orthogonal (n=45) as per the following formula:
(1) standard ruler method = longest length X widest width
(2) ellipse = longest length X widest width X 0.785
(3) optimized (p) = longest length X widest width X 0.73
(4) optimized (v) = longest length X widest width X 0.67
Visual representation of over-estimation and underestimation
The over- and underestimation of all the measurements were graphically depicted for the standard ruler, elliptical, optimized (P), and optimized (V) measurement methods. A helpful visual representation of the relationship between two paired variables on the same scale is represented on the the Bland-Altman plot, which was used to compare the following variables: smartphone application measurement vs. standard ruler, smartphone application measurement vs elliptical, smartphone application measurement vs. optimized (P) and smartphone application measurement vs optimized (V).
Results
Cutaneous wounds of elephants (n=111)
One hundred eleven observations from 35 wounds of captive Asian elephants at different stages were collected for study. The mean length was 8.45 ± 0.54 cm, the smallest was 0.64 cm, and the lengthiest was 33.94 cm (Table 1). The mean width was 4.23 ± 0.34 cm, the smallest was 0.23 cm, and the widest was 19.76 cm. The mean area was 34.61 ± 5.31 cm2, the smallest was 0.09 cm2, and the largest was 352.14 cm2. The mean perimeter was 21.83 ± 1.51 cm, where the smallest was 1.39 cm and the largest was 103.14 cm (Table 1).
Table 1. Mean, median, SD, SE, and mean ± SE.
Whole data (n=111) | |||||
Mean | Median | SD | SE | Mean ± SE | |
Length | 8.454864865 | 7.36 | 5.681298486 | 0.53924499 | 8.45 ± 0.54 cm |
Width | 4.230900901 | 2.95 | 3.632824483 | 0.34481244 | 4.23 ± 0.34 cm |
Area | 34.60873874 | 15.64 | 55.69406136 | 5.3102204 | 34.61 ± 5.31 cm2 |
Perimeter | 21.83396396 | 18.35 | 15.89293206 | 1.50849035 | 21.83 ± 1.51 cm |
Cutaneous wounds with orthogonal measurements (n=66)
Sixty-six observations (59.46 % of total observations) from different wounds of captive Asian elephants at different stages were collected for this study. The mean length, width, area, and perimeter are presented in Table 2.
Table 2. Mean, median, SD, SE, and mean ± SE.
Orthogonal measurements (n=66) | |||||
Mean | Median | SD | SE | Mean ± SE | |
Length | 8.501060606 | 8.365 | 4.675261944 | 0.575484963 | 8.50 ± 0.58 cm |
Width | 4.731363636 | 3.77 | 3.262563356 | 0.401593788 | 4.73 ± 0.40 cm |
Area | 35.66939394 | 22.51 | 48.75259715 | 6.001029872 | 35.67 ± 6.00 cm2 |
Perimeter | 22.79015152 | 23.33 | 12.99571296 | 1.599661685 | 22.79 ± 1.59 cm |
Standard | 52.28987576 | 38.37035 | 69.19285012 | 8.517051087 | 52.29 ± 8.51 cm2 |
RMS error (Std) | 51.37361897 | 46.25631122 | 20.58123252 | 2.533374598 | 51.37 ± 2.53 % |
Elliptical | 41.04755247 | 30.12072475 | 54.31638735 | 6.685885103 | 41.05 ± 6.69 cm2 |
RMS error (Eli) | 18.88623725 | 14.8112043 | 16.08744663 | 1.980227792 | 18.88 ± 1.98 % |
Optimized (P) | 38.1716093 | 28.0103555 | 50.51078059 | 6.217447293 | 38.17 ± 6.22 cm2 |
RMS error (Opt-p) | 12.18219026 | 6.885205916 | 13.67644997 | 1.683454618 | 12.18 ± 1.68 % |
Optimized (V) | 35.03421676 | 25.7081345 | 46.35920958 | 5.706424228 | 35.03 ± 5.71 cm2 |
RMS error (Opt-v) | 9.816076114 | 7.632216017 | 9.713849977 | 1.195692277 | 9.82 ± 1.20 % |
The Ac (elliptical) calculation in this dataset showed an overestimation of the area in 65 calculations (98.48%), and the average overestimation was 19.15 ± 1.99%. It is shown that underestimation in one analysis (1.52%) and average underestimation was 1.91% (Tables 3-4). However, the Ac optimized (P) calculation in this dataset shows an underestimation of the area in 16 out of 66 measures (24.24%). The average underestimation was 3.46 ± 0.64%. Fifty out of 66 calculations (75.76%) showed overestimation (Tables 3-4). The average overestimation was 14.97 ± 2.07%. The Ac optimized (V) calculation in this dataset shows an underestimation of the area in 38 out of 66 calculations (57.58%). The average underestimation was 7.29 ± 0.70%. Twenty-eight out of 66 calculations (42.42%) showed overestimation. The average overestimation was 13.24 ± 2.54%. The root mean square (RMS) errors of Ac standard and Ac elliptical are close to their averages but at the upper level (Tables 3-4). This means that standard and elliptical calculation consistently overestimates the area in these observations, but optimized calculations can lead to overestimation or underestimation. This may be because the optimization formula used here was developed for plantar and venous ulcers in human beings.
Table 3. Comparison of the methods for the overestimation and underestimation.
Orthogonal measurements (n=66) | ||||||
Method | Overestimation | Underestimation | ||||
Count | % Count | % Area | Count | % Count | % Area | |
Standard | 100 | 100 | 48.09 ± 2.53 | 0 | 0 | 0 |
Elliptical | 100 | 100 | 12.66 ± 1.98 | 0 | 0 | 0 |
Optimized (p) | 50 | 75.76 | 8.65 ± 2.07 | 16 | 24.24 | 1.79 ± 0.64 |
Optimized (v) | 28 | 42.42 | 6.58 ± 2.54 | 38 | 57.58 | 5.38 ± 0.70 |
Table 4. Error percentage of orthogonal measures in different calculations (n=66).
Error %/Method | Standard | Elliptical | Optimized (P) | Optimized (V) | ||||
Count | % | Count | % | Count | % | Count | % | |
0-9 | 0 | 0 | 24 | 36.36 | 43 | 65.15 | 43 | 65.15 |
10-19 | 0 | 0 | 20 | 30.30 | 9 | 13.64 | 17 | 25.76 |
20-29 | 4 | 6.06 | 8 | 12.12 | 8 | 12.12 | 2 | 3.03 |
30-39 | 20 | 30.30 | 8 | 12.12 | 2 | 3.03 | 2 | 3.03 |
40-49 | 16 | 24.24 | 1 | 1.52 | 2 | 3.03 | 2 | 3.03 |
50-59 | 9 | 13.64 | 1 | 1.52 | 1 | 1.52 | 0 | 0 |
60-69 | 9 | 13.64 | 3 | 4.55 | 1 | 1.52 | 0 | 0 |
70-79 | 2 | 3.03 | 1 | 1.52 | 0 | 0 | 0 | 0 |
80-89 | 1 | 1.52 | 0 | 0 | 0 | 0 | 0 | 0 |
90-99 | 1 | 1.52 | 0 | 0 | 0 | 0 | 0 | 0 |
100 and above | 4 | 6.06 | 0 | 0 | 0 | 0 | 0 | 0 |
The overestimation and underestimation of all the measurements (n=66) for orthogonal measurements and 45 for non-orthogonal measurements) were presented in Figure 1 for standard, elliptical, optimized (P), and optimized (V) measurement methods.
Figure 1. Over- or underestimation of area measurements (n=111).
Cutaneous wounds with non-orthogonal measurements (n=45)
Forty-five (40.54% of the total) observations from different wounds of captive Asian elephants at different stages were collected for this study. The mean length, width, area, and perimeter are presented in Table 5. The Ac (standard) calculation in this dataset shows an overestimation of the area consistently. The average variation or mean RMS error was 55.45 ± 4.99%.
Table 5. Mean, median, SD, SE, and mean ± SE.
Non-orthogonal measurements (n=45) | |||||
Mean | Median | SD | SE | Mean ± SE | |
Length | 8.387111111 | 5.98 | 6.956626214 | 1.037032607 | 8.39 ± 1.04 cm |
Width | 3.496888889 | 1.86 | 4.04255591 | 0.602628654 | 3.50 ± 0.60 cm |
Area | 33.05311111 | 6.62 | 65.10916727 | 9.705901599 | 33.05 ±9.71 cm2 |
Perimeter | 20.43155556 | 12.29 | 19.45728339 | 2.900520555 | 20.43 ± 2.90 cm |
Standard | 50.59630444 | 9.394 | 109.6128236 | 16.34011498 | 50.60 ± 16.34 cm2 |
RMS error (Std) | 55.45092638 | 45.61625 | 33.47986973 | 4.990884306 | 55.45 ± 4.99% |
Elliptical | 39.71809899 | 7.37429 | 86.04606651 | 12.82699026 | 39.72 ± 12.83 cm2 |
RMS error (Eli) | 22.0289772 | 14.3087563 | 26.28169774 | 11.92828394 | 22.03 ± 11.93% |
Optimized (P) | 36.93530224 | 6.85762 | 80.01736122 | 3.91784418 | 36.94 ± 3.92 cm2 |
RMS error (Opt-p) | 14.78302612 | 6.2998625 | 23.65673989 | 3.526538568 | 14.78 ± 3.53% |
Optimized (V) | 33.89952398 | 6.29398 | 73.4405918 | 10.94787704 | 33.90 ± 10.95 cm2 |
RMS Error (Opt-v) | 12.23472508 | 8.48063793 | 19.17587496 | 2.858570662 | ± 2.89 % |
The Ac (elliptical) calculation in this dataset shows an overestimation of the area consistently. The average variation or mean RMS error was 22.03 ± 11.93%. However, the Ac optimized (P) calculation in this dataset shows an underestimation of the area in 11 out of 45 calculations (24.44%). The average underestimation was 2.67 ± 0.63%. Thirty-four out of 45 calculations (75.56%) showed an overestimation. The average overestimation was 18.70 ± 4.47%. Ac optimized (V) calculation in this dataset shows an underestimation of the area in 23 out of 45 calculations (51.11%). The average underestimation was 7.91 ± 0.67%. Twenty-two out of 45 calculations (48.89%) showed an overestimation. The average overestimation was 16.76 ± 5.71%. The RMS errors of Ac standard and Ac elliptical are near to their averages, but at a higher level. This means that standard and elliptical calculation consistently overestimates the area in these observations, but optimized calculations can lead to an overestimation or underestimation. This may be because the optimization formula used here was developed for plantar and venous ulcers in humans.
For cutaneous wounds with non-orthogonal measurements, 45 (40.54% of the total) observations from different wounds of captive Asian elephants at different stages were collected for this study. The overestimation values for % wound area were noted to be 50.32 ± 4.99, 14.21 ± 11.93, 9.77 ± 4.47, and 8.87 ± 5.71 for standard, elliptical, optimized (p), and optimized (v) methods, respectively (Table 6). The error percentage for orthogonal measures in different calculations was calculated. The results indicated that orthogonal (V) measurements have the lowest error percentage across all ranges. No error percentage was found at 30-39% and 40-49% at orthogonal measurements. The elliptical measurements recorded the highest error percentages at 30-39% and 40-49%. The standard and optimized (P) methods are in between, with the optimized (P) value having a slight error percentage lower than the standard (Table 7).
Table 6. Comparison of methods for the overestimation and underestimation.
Orthogonal measurements (n=45) | ||||||
Method | Overestimation | Underestimation | ||||
Count | % Count | % Area | Count | % Count | % Area | |
Standard | 100 | 100 | 50.32 ± 4.99 | 0 | 0 | 0 |
Elliptical | 100 | 100 | 14.21 ± 11.93 | 0 | 0 | 0 |
Optimized (p) | 34 | 75.56 | 9.77 ± 4.47 | 11 | 24.44 | 1.59 ± 0.63 |
Optimized (v) | 22 | 48.89 | 8.87 ± 5.71 | 23 | 51.11 | 7.22 ± 0.67 |
Table 7. Error percentage of orthogonal measures in different calculations (n=45).
Error %/Method | Standard | Elliptical | Optimized (P) | Optimized (V) | ||||
Count | % | Count | % | Count | % | Count | % | |
0-9 | 0 | 0.00 | 14 | 31.11 | 23 | 51.11 | 27 | 60.00 |
10-19 | 0 | 0.00 | 14 | 31.11 | 11 | 24.44 | 13 | 28.89 |
20-29 | 2 | 4.44 | 6 | 13.33 | 6 | 13.33 | 4 | 8.89 |
30-39 | 12 | 26.67 | 6 | 13.33 | 4 | 0.00 | 0 | 0.00 |
40-49 | 9 | 20.00 | 4 | 8.89 | 0 | 0.00 | 0 | 0.00 |
50-59 | 8 | 17.78 | 0 | 0.00 | 0 | 0.00 | 0 | 0.00 |
60-69 | 5 | 11.11 | 0 | 0.00 | 0 | 0.00 | 0 | 0.00 |
70-79 | 4 | 8.89 | 0 | 0.00 | 0 | 0.00 | 0 | 0.00 |
80-89 | 4 | 8.89 | 0 | 0.00 | 0 | 0.00 | 0 | 0.00 |
90-99 | 0 | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 | 0.00 |
100 and above | 1 | 2.22 | 1 | 2.22 | 1 | 2.22 | 1 | 2.22 |
The Bland-Altman plots were used to represent the relationship between smartphone application measurement vs standard ruler, smartphone application measurement vs elliptical, smartphone application measurement vs. optimized (p), and smartphone application measurement vs. optimized (p) are shown in Figures 2-5.
Figure 2. Bland-Altman plot area vs. standard.
Figure 3. Bland-Altman plot area vs. ellipse.
Figure 4. Bland-Altman plot area vs. optimized (p).
Figure 5. Bland-Altman plot area vs. optimized (v).
Statistical analysis
One-way ANOVA was used to check the difference between various measurements. Independent two-sample t-tests were used for comparing measurement methods via orthogonal and non-orthogonal measurements. The one-way ANOVA study shows no statistically significant relations between the five types of measurement methods in the orthogonal and non-orthogonal measurement sections. The p-values were greater than 0.05, suggesting no significant correlation (Table 8). The t-test also demonstrated no significant relationship between the mean of the two groups (measurement methods via orthogonal and non-orthogonal measurements), as the P-value was greater than 0.05 (Table 9).
Table 8. One-way ANOVA test for the measurement methods.
Sl. No | Measurement methods | Area measurements (cm2), mean ± SE | ||
All (n=111) | OM (n=66) | NOM (n=45) | ||
1. | Imito Measure app (A) | 34.61 ± 5.31 | 35.67 ± 4.65 | 33.05 ± 9.71 |
2. | Standard ruler (Acs) | 51.60 ± 8.29 | 52.29 ± 6.59 | 50.60 ± 16.34 |
3. | Ellipse (Ace) | 40.51 ± 6.51 | 41.05 ± 5.18 | 39.72 ± 12.83 |
4. | Optimized-p (Acop) | 37.67 ± 1.97 | 38.17 ± 4.82 | 36.94 ± 3.92 |
5. | Optimized-v (Acov) | 34.57 ± 5.56 | 35.03 ± 4.42 | 33.90 ± 10.94 |
6. | f-value | 1.2013 | 1.1021 | 0.3181 |
7. | p-value | 0.3092 | 0.3555 | 0.8657 |
Table 9. T-test for the measurement methods.
Since the p-value is > 0.05, there is no significant difference between the five area measurement methods in all orthogonal and non-orthogonal measurements.
OM-orthogonal measurements (n=66), NOM-non orthogonal measurement
Variable | Conditions | Mean | t-stat | p-value |
Standard ruler | OM | 52.29 | -0.09 | 0.93 |
NOM | 50.60 | |||
Ellipse | OM | 41.05 | -0.09 | 0.93 |
NOM | 39.72 | |||
Optimized (p) | OM | 38.17 | -0.09 | 0.93 |
NOM | 26.94 | |||
Optimized (v) | OM | 35.03 | -0.09 | 0.93 |
NOM | 33.90 |
Discussion
For venous and arterial cutaneous wounds, area measurement is suggested [14,15]. Just 5% of clinical trials regarding wound assessment in human wounds have addressed the validity or reliability of measuring methodologies [16]. The major methods employed in clinical studies are planimetry digital photography, computer software program analysis, direct measurement of wound diameters, specialized photographic software (using a smartphone application), and laser technology [17,18]. Although other approaches are available, computer software programs and planimetry have been the most widely used. The ideal approach would provide precision, dependability, and practicality simultaneously. When employed as a point-of-care tool, using a smartphone app promotes high feasibility [19]. Comparisons with a previously tested approach will assure consistency and interrater agreement [18].
Smartphones with high-definition digital cameras nowadays are readily available and reasonably priced. Such gadgets' exceptional portability and mobility are particularly inspiring for therapeutic applications. Imito and other smartphone-specific apps have arisen to make wound assessment and documentation easier and more straightforward [20]. The Imito app is a noncontact digital planimetry app with an edge over other approaches. When used to record, quantify, and evaluate metatarsal wound photos in a cat patient, the ImitoMeasure app found strong correlations across all studied metrics. Furthermore, the application enabled a noncontact, simple, and reliable smart wound-measuring solution [21].
For measuring the cutaneous wounds of elephants, 111 observations from 35 different wounds of captive Asian elephants at different stages were collected for study. The mean length was 8.45 ± 0.54 (Table 1), the mean width was 4.23 ± 0.34 (Table 1), the mean area was 34.61 ± 5.31 cm2, and the mean perimeter was noted to be 21.83 ± 1.51 cm. The overestimation value for the standard ruler method was 53.03%, while those of the other three methods were comparatively lower. When compared to digital planimetry, Rogers et al. discovered that the basic ruler approach underestimated the wound area by 41% on average [12]. Similarly, Shetty et al. [22] found that the simple ruler approach was overestimated by 29-43% compared to manual planimetry.
For cutaneous wounds with orthogonal measurements, 66 observations (59.46% of total observations) from different wounds of captive Asian elephants at different stages were collected for this study. The overestimation values for % wound area were noted to be 48.09 ± 2.53, 12.66 ± 1.98, 8.65 ± 2.07, and 6.58 ± 2.54 for standard ruler, elliptical, optimized (p), and optimized (v) methods, respectively. This may be because the optimization formula used here was developed for plantar and venous ulcers in humans. The plantar and palmar areas in humans are smaller in size compared to that of elephants.
For cutaneous wounds with non-orthogonal measurements, 45 (40.54% of the total) observations from different wounds of captive Asian elephants at different stages were collected for this part of the study. The overestimation values for % wound area were noted to be 50.32 ± 4.99, 14.21 ± 11.93, 9.77 ± 4.47, and 8.87 ± 5.71 for standard ruler, elliptical, optimized (p), and optimized (v) methods, respectively. This may be because the optimization formula used here was developed for the plantar and venous ulcers in human beings (Table 6).
Graphical representation provided a quick overview of the over and underestimation, as in Figure 1. Visual representation of the relationship between different measurement calculations against measurements done by the smartphone applications over the same scale done by Bland-Altman plots provided the ability to see a phenomenon but did not test it. In other words, it did not give us the same chance of error on a judgment regarding the variables that a test would do [23].
The observed results indicated no significant difference between the five methods of area measurement in all the studied cases (orthogonal and non-orthogonal measurements) since the p-value is > 0.05. However, published literature has demonstrated varied outcomes. For instance, Oien et al. examined four wound area assessment methods in 20 individuals with 50 chronic leg ulcers from various causes [24]. Digital planimetry, mechanical planimetry, grid tracing (manual planimetry), and a basic ruler approach were used. All approaches indicated a high level of concordance in wounds less than 10 cm2 (p < 0.01), although discrepancies emerged as wound size increased. It has previously been demonstrated that digital planimetry produces less variability than manual planimetry [25]. On the other hand, the Visitrak® system, which uses a tracing grid sheet for manual tracing and a digital pad for calculating the wound dimensions, revealed strong intra and interrater reliability, with a substantial positive correlation (p < 0.001) between the said system and the digital imaging approach when evaluated in 30 pressure ulcers [9].
The major strength of this study was that it was conducted in clinical cases. Hence, the wound areas under the study varied widely, from 0.09 cm2 to 352.14 cm2, which helped to test the feasibility of the proposed methods under study in a wide range of area measurements without any prejudice of the expected healing pattern of created wounds of known size. Another strong point about the study was that the same person did all the measurements to avoid individual variations in performing the measuring technique when more people were doing it.
The study has the possible limitations as follows. The study was planned in such a way that the data collection should be non-contact and with the least animal discomfort. Hence, the possible level of animal discomfort in contact measuring techniques could not be assessed. Another thing is that this study compared only the mathematical calculations in order to check whether these formulas are dependable irrespective of the data source. The study did not assess the existing data collection methodologies in detail as it was beyond the scope of this study.
Conclusions
If wound measurement techniques are to be beneficial for assessing the process of wound healing, they must be accurate, reliable, and feasible. The published studies revealed that wound measurement methods, including digital planimetry, are less validated by clinical trials. When utilized correctly, digital planimetry may be employed in wound area assessment and therapy evaluation, and the results indicate that smartphone digital planimetry has an advantage over existing procedures in terms of practical usability and electronic medical documentation. In animals, being a non-contact technique, this has an edge over other methods in terms of welfare concerns. Smartphones with high-definition digital cameras are now readily available, and their exceptional portability and mobility are especially promising for therapeutic applications. Smartphone-specific apps have arisen to make wound assessment and documentation more straightforward.
In this study, four traditional methods (mathematical calculation) applied in 111 wound area measurements are compared with a noncontact digital planimetry app, Imito Measure. The area of wounds ranged from 0.09 cm2 to 352.14 cm2. We found that all four mathematical methods overestimated (the highest being 53.03%) or underestimated (the highest being 7.52%) the wound area, consistent with previous studies. However, in all of the cases analyzed in the present study, the observed findings revealed no statistically significant difference between the five techniques of wound area measurement. From the practical clinical utility point, the smartphone application has the edge over the four mathematical methods used in this study, especially in captive Asian elephants, as it has the advantage of being non-contact and thus addresses some major welfare concerns. As suggested in the previous studies, assessment methods must be accurate, trustworthy, and practical for daily clinical work and clinical research investigations when comparing treatment regimens, and the ImitoMeasure app perfectly fits into this.
Acknowledgments
We, the authors, sincerely thank the team members involved in this study for their help and support. We also thank the Dean, College of Veterinary and Animal Sciences, and the Professor and Head, Teaching Clinical Veterinary Complex, Mannuthy, Thrissur, Kerala, India, for the clinical and laboratory facilities and B R Vishnu for kindly providing the necessary support for the data analysis and the visual representation.
Disclosures
Human subjects: All authors have confirmed that this study did not involve human participants or tissue.
Animal subjects: Kerala Veterinary and Animal Sciences University Issued protocol number XIIIth FRC.
Conflicts of interest: In compliance with the ICMJE uniform disclosure form, all authors declare the following:
Payment/services info: All authors have declared that no financial support was received from any organization for the submitted work.
Financial relationships: All authors have declared that they have no financial relationships at present or within the previous three years with any organizations that might have an interest in the submitted work.
Other relationships: All authors have declared that there are no other relationships or activities that could appear to have influenced the submitted work.
Author Contributions
Concept and design: Mulluparambil K. Narayanan, Thyagaraj Giggin, Kurisinkal D. Martin
Drafting of the manuscript: Mulluparambil K. Narayanan, Thyagaraj Giggin, Kurisinkal D. Martin
Supervision: Mulluparambil K. Narayanan, Thyagaraj Giggin, Kundukulam S. Anil, Arayinkaravattu R. Sreeranjini
Critical review of the manuscript for important intellectual content: Thyagaraj Giggin, Syam K. Vebugopal, Kundukulam S. Anil, Arayinkaravattu R. Sreeranjini
Acquisition, analysis, or interpretation of data: Syam K. Vebugopal, Kundukulam S. Anil, Arayinkaravattu R. Sreeranjini
References
- 1.Mikota SK. Integument System. Hoboken, NJ: Blackwell Publishing; 2006. Biology, Medicine, and Surgery of Elephants; pp. 253–261. [Google Scholar]
- 2.Elephant health status in Thailand: the role of mobile elephant clinic and elephant hospital. Angkawanish T, Boonprasert K, Homkong P, et al. https://www.asesg.org/PDFfiles/Gajah/31-15-20-Angkawanish.pdf Gajah. 2009;31:15–20. [Google Scholar]
- 3.Relationships between housing and management factors and clinical health events in elephants in North American zoos. Edwards KL, Miller MA, Carlstead K, Brown JL. PLoS One. 2019;14:0. doi: 10.1371/journal.pone.0217774. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.A visual health assessment of captive Asian elephants (Elephas maximus) housed in India. Ramanathan A, Mallapur A. J Zoo Wildl Med. 2008;39:148–154. doi: 10.1638/2007-0008R1.1. [DOI] [PubMed] [Google Scholar]
- 5.Sajesh MG. Khanapara, India: Assam Agricultural University; 2009. Traumatic Injuries in the Working Elephants of Assam and Kerala - A Comparative Study. [Google Scholar]
- 6.Methods to assess area and volume of wounds - a systematic review. Jørgensen LB, Sørensen JA, Jemec GB, Yderstraede KB. Int Wound J. 2016;13:540–553. doi: 10.1111/iwj.12472. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.An assessment of the accuracy and usability of a novel optical wound measurement system. Bowling FL, King L, Fadavi H, et al. Diabet Med. 2009;26:93–96. doi: 10.1111/j.1464-5491.2008.02611.x. [DOI] [PubMed] [Google Scholar]
- 8.Efficacy and prognostic value of simple wound measurements. Kantor J, Margolis DJ. Arch Dermatol. 1998;134:1571–1574. doi: 10.1001/archderm.134.12.1571. [DOI] [PubMed] [Google Scholar]
- 9.A study of the efficiency and convenience of an advanced portable wound measurement system (Visitrak) Sugama J, Matsui Y, Sanada H, Konya C, Okuwa M, Kitagawa A. J Clin Nurs. 2007;16:1265–1269. doi: 10.1111/j.1365-2702.2007.01790.x. [DOI] [PubMed] [Google Scholar]
- 10.Wound measurement comparing the use of acetate tracings and Visitrak digital planimetry. Gethin G, Cowman S. J Clin Nurs. 2006;15:422–427. doi: 10.1111/j.1365-2702.2006.01364.x. [DOI] [PubMed] [Google Scholar]
- 11.A comparison of computer-assisted and manual wound size measurement. Thawer HA, Houghton PE, Woodbury MG, Keast D, Campbell K. https://pubmed.ncbi.nlm.nih.gov/12378003/ Ostomy Wound Manag. 2002;48:46–53. [PubMed] [Google Scholar]
- 12.Digital planimetry results in more accurate wound measurements: a comparison to standard ruler measurements. Rogers LC, Bevilacqua NJ, Armstrong DG, Andros G. J Diabetes Sci Technol. 2010;4:799–802. doi: 10.1177/193229681000400405. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Comparisons of venous and diabetic plantar ulcer shape and area. Mayrovitz HN, Smith J, Ingram C. http://clinsoft.org/drmayrovitz/PAPERS-HNM/1998_066-DM-and-VenousUlcerShape.pdf. Adv Wound Care. 1998;11:176–183. [PubMed] [Google Scholar]
- 14.Management of venous leg ulcers: clinical practice guidelines of the Society for Vascular Surgery ® and the American Venous Forum. O'Donnell TF Jr, Passman MA, Marston WA, et al. J Vasc Surg. 2014;60:3–59. doi: 10.1016/j.jvs.2014.04.049. [DOI] [PubMed] [Google Scholar]
- 15.Reporting standards of the Society for Vascular Surgery for endovascular treatment of chronic lower extremity peripheral artery disease. Stoner MC, Calligaro KD, Chaer RA, et al. J Vasc Surg. 2016;64:0–21. doi: 10.1016/j.jvs.2016.03.420. [DOI] [PubMed] [Google Scholar]
- 16.Heterogeneity of wound outcome measures in RCTs of treatments for VLUs: a systematic review. Gethin G, Killeen F, Devane D. J Wound Care. 2015;24:211–226. doi: 10.12968/jowc.2015.24.5.211. [DOI] [PubMed] [Google Scholar]
- 17.Ways to increase precision and accuracy of wound area measurement using smart devices: advanced app Planimator. Foltynski P. PLoS One. 2018;13:0. doi: 10.1371/journal.pone.0192485. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Point-of-care wound visioning technology: reproducibility and accuracy of a wound measurement app. Wang SC, Anderson JAE, Evans R, Woo K, Beland B, Sasseville D, Moreau L. PLoS One. 2017;12:0. doi: 10.1371/journal.pone.0183139. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Wound measurement tools and techniques: a review. Wendland DM, Taylor DW. J Acute Care Phys Ther. 2017;8:42–57. [Google Scholar]
- 20.Teleconsultation by using the mobile camera phone for remote management of the extremity wound: a pilot study. Tsai HH, Pong YP, Liang CC, Lin PY, Hsieh CH. Ann Plast Surg. 2004;53:584–587. doi: 10.1097/01.sap.0000130703.45332.3c. [DOI] [PubMed] [Google Scholar]
- 21.Clinical benefits of using a smartphone application to assess the wound healing process in a feline patient - a case report. Bodea IM, Dîrlea SA, Mureşan C, Fiţ NI, Beteg FI. Top Companion Anim Med. 2021;42:100498. doi: 10.1016/j.tcam.2020.100498. [DOI] [PubMed] [Google Scholar]
- 22.A novel and accurate technique of photographic wound measurement. Shetty R, Sreekar H, Lamba S, Gupta AK. Indian J Plast Surg. 2012;45:425–429. doi: 10.4103/0970-0358.101333. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Riffenburgh RH, Gillen DL. Statistics in Medicine. Cambridge, MA: Academic Press; 2020. Statistics in Medicine. [Google Scholar]
- 24.Measuring the size of ulcers by planimetry: a useful method in the clinical setting. Oien RF, Håkansson A, Hansen BU, Bjellerup M. J Wound Care. 2002;11:165–168. doi: 10.12968/jowc.2002.11.5.26399. [DOI] [PubMed] [Google Scholar]
- 25.Wound measurement: the comparative reliability of direct versus photographic tracings analyzed by planimetry versus digitizing techniques. Lagan KM, Dusoir AE, McDonough SM, Baxter GD. Arch Phys Med Rehabil. 2000;81:1110–1116. doi: 10.1053/apmr.2000.6281. [DOI] [PubMed] [Google Scholar]