Discordance in acute gastrointestinal toxicity between synchrotron-based proton and linac-based electron ultra-high dose rate irradiation

Kevin Liu, Uwe Titt, Nolan Esplen, Luke Connell, Elise Konradsson, Ming Yang, Xiaochun Wang, Takeshi Takaoka, Ziyi Li, Albert C Koong, Devarati Mitra, Radhe Mohan, Billy W Loo, Steven H Lin, Emil Schüler
PMCID: PMC11398481  PMID: 39282305

ABSTRACT

Purpose

Proton FLASH has been investigated using cyclotron and synchrocyclotron beamlines but not synchrotron beamlines. We evaluated the impact of dose rate (ultra-high [UHDR] vs. conventional [CONV]) and beam configuration (shoot-through [ST] vs. spread-out-Bragg-peak [SOBP]) on acute radiation-induced gastrointestinal toxicity (RIGIT) in mice. We also compared RIGIT between synchrotron-based protons and linac-based electrons with matched mean dose rates.

Methods and Materials

We administered abdominal irradiation (12-14 Gy single fraction) to female C57BL/6J mice with an 87 MeV synchrotron-based proton beamline (2 cm diameter field size as a lateral beam). Dose rates were 0.2 Gy/s (S-T pCONV), 0.3 Gy/s (SOBP pCONV), 150 Gy/s (S-T pFLASH), and 230 Gy/s (SOBP pFLASH). RIGIT was assessed by the jejunal regenerating crypt assay and survival. We also compared responses to proton [pFLASH and pCONV] with responses to electron CONV (eCONV, 0.4 Gy/s) and electron FLASH (eFLASH, 188-205 Gy/s).

Results

The number of regenerating jejunal crypts at each matched dose was lowest for pFLASH (similar between S-T and SOBP), greater and similar between pCONV (S-T and SOBP) and eCONV, and greatest for eFLASH. Correspondingly, mice that received pFLASH SOBP had the lowest survival rates (50% at 50 days), followed by pFLASH S-T (80%), and pCONV SOBP (90%), but 100% of mice receiving pCONV S-T survived (log-rank P = 0.047 for the four groups).

Conclusions

Our findings are consistent with an increase in RIGIT after synchrotron-based pFLASH versus pCONV. This negative proton-specific FLASH effect versus linac-based electron irradiation underscores the importance of understanding the physical and biological factors that will allow safe and effective clinical translation.