Three microarray platforms: an analysis of their concordance in profiling gene expression

David Petersen 1,#, GVR Chandramouli 1,#, Joel Geoghegan 1, Joanne Hilburn 1, Jonathon Paarlberg 1, Chang Hee Kim 2, David Munroe 2, Lisa Gangi 2, Jing Han 3, Raj Puri 3, Lou Staudt 4, John Weinstein 4, J Carl Barrett 4, Jeffrey Green 4, Ernest S Kawasaki 1,
PMCID: PMC1140753  PMID: 15876355

Abstract

Background

Microarrays for the analysis of gene expression are of three different types: short oligonucleotide (25–30 base), long oligonucleotide (50–80 base), and cDNA (highly variable in length). The short oligonucleotide and cDNA arrays have been the mainstay of expression analysis to date, but long oligonucleotide platforms are gaining in popularity and will probably replace cDNA arrays. As part of a validation study for the long oligonucleotide arrays, we compared and contrasted expression profiles from the three formats, testing RNA from six different cell lines against a universal reference standard.

Results

The three platforms had 6430 genes in common. In general, correlation of gene expression levels across the platforms was good when defined by concordance in the direction of expression difference (upregulation or downregulation), scatter plot analysis, principal component analysis, cell line correlation or quantitative RT-PCR. The overall correlations (r values) between platforms were in the range 0.7 to 0.8, as determined by analysis of scatter plots. When concordance was measured for expression ratios significant at p-values of <0.05 and at expression threshold levels of 1.5 and 2-fold, the agreement among the platforms was very high, ranging from 93% to 100%.

Conclusion

Our results indicate that the long oligonucleotide platform is highly suitable for expression analysis and compares favorably with the cDNA and short oligonucleotide varieties. All three platforms can give similar and reproducible results if the criterion is the direction of change in gene expression and minimal emphasis is placed on the magnitude of change.

Background

Completion of the human genome sequence has made it possible to study expression of the entire complement of 20,000–30,000 genes in a single assay. The two most common array platforms are based on collections of cDNA clones [1] or short (25 base) oligonucleotides synthesized in situ by photolithographic methods (i.e., by Affymetrix, Inc.) [2]. Partly because they are easy to use, microarrays are the most extensively used technology for studying gene expression on a global scale [3,4]. Thousands of expression studies employ one or the other microarray platform, but comparison of results between platforms has been difficult because of inherent differences in the array technologies. The situation became more complex as investigators began using long oligonucleotide arrays for expression profiling [5-9].

Because long oligonucleotide arrays for expression profiling are relatively new, we wished to validate them in relation to the cDNA and short oligonucleotide platforms, both of which have been used extensively in our laboratories over a number of years. The three platforms were evaluated using RNAs isolated from six cell lines and tested against a universal reference RNA. Sufficient RNA was isolated in a single harvest to supply labeling template for all experiments, so variability of RNA isolation was not an issue. However, no attempt was made to eliminate other sources of variation such as differences between lots of fluorescent dye label, microarray batch, operator, etc. We conducted these experiments under "normal" laboratory conditions so that one would not need to go to extreme lengths to reproduce the results. In almost all cases, results from the three platforms correlated reasonably well with each other. The Pearson correlation coefficients (r) ranged from 0.7 to 0.8. Because of different labeling methods and analysis algorithms, comparison of the cDNA and long oligonucleotide platforms with the short oligonucleotide system was not as straightforward, but in general all of the platforms were in reasonable agreement.

Results

This study was carried out to compare cDNA (Incyte), long oligonucleotide (Operon 70-mer), and short 25-mer (Affymetrix) array platforms, with the goal of qualifying the 70-mer arrays for general use at the National Cancer Institute. More specifically, we compared the Incyte Unigem2 set of human cDNAs (~9900 genes), the Operon human Version 2.0 set of long oligonucleotides (~21,329 genes), and Affymetrix HG-U133A arrays (~22,200 genes). RNA preparations from cell lines MCF10A, LNCaP, Jurkat, L428, SUDHL6, and OCI-Ly3 were used as probe templates, and the expression of each gene was compared directly with that of the same gene in the Human Universal Reference (HUR) RNA from Stratagene.

Genes in common across platforms

Only genes common to all three platforms were used in the comparison. Genes were matched by UniGene Cluster (UniGene Build #161), and unique cluster memberships were determined for each array type, as listed in Table 1 and enumerated in the Venn diagram in Figure 1. The intersection for the three platforms consisted of 6430 UniGene clusters, and all analyses were carried out with all of these genes or a subset of them.

Table 1.

Overlapping gene sets represented in 3 microarray platforms

Incyte UniGEM2 Hs-Operon V2 HG-U133A
Total features / probe sets: 9128 21522 22215
Distinct UniGene clusters: 8097 19179 13899
UniGem2 & Operon V2 UniGEM2 & HG-U133A Operon V2 & HG-U133A
Genes in common 7082 6593 12999
Genes in common in all arrays 6430 6430 6430

Figure 1.

Figure 1

Venn diagram with number of genes present in each platform, genes in common between platforms, and genes in common among all three platforms.

Comparison of expression ratios

An estimate of the concordance of the platforms was provided by the percentage of genes that showed expression ratios "in the same direction." All matched gene sets that had expression ratios (relative to the Universal Standard) greater than 1.0, irrespective of magnitude, were considered to be in the same direction, and the same for expression ratios less than 1.0. As seen in Table 2, the agreement was reasonably good, ranging from 74% to 82%. For comparison, ~50% concordance would be expected by chance. Many of the discordant values were at what might be considered "trivial" levels because a large proportion of ratios are near unity. For example, approximately 48%, 28% and 13% of the genes from Incyte, Operon and Affymetrix respectively, exhibit expression ratios within the range of 1.1 to 0.9. Thus, a ratio difference of only 0.95 versus 1.05 is designated a mismatch, which normally would be considered very concordant in the biological sense.

Table 2.

Proportion of genes expressed in same direction between platforms ignoring expression level. The numbers of genes in matched and mismatched directions are given for each cell line and each platform pair, and agreement is given in percentages.

Array Platform: Cell line: Direction-matched Direction-mismatched (ignoring expression level) Total number of genes used in calculation Percent agreement in direction
GEM2 & Operon V2 Jurkat 4597 1373 5970 77 %
L428 3535 1251 4786 74 %
SUDHL 4608 1525 6133 75 %
Ocily3 4094 1368 5462 75 %
LNCaP 4189 1333 5522 76 %
MCF10A 4469 1429 5898 76 %
Total 25492 8279 33771 75 %

GEM2 & HG-U133A Jurkat 3657 906 4563 80 %
L428 3203 918 4121 78 %
SUDHL 3541 809 4350 81 %
Ocily3 3826 984 4810 80%
LNCaP 3747 1031 4778 78 %
MCF10A 3584 950 4534 79 %
Total 21558 5598 27156 79 %

Operon V2 & HG-U133A Jurkat 3688 795 4483 82 %
L428 2909 738 3647 80 %
SUDHL 3520 776 4296 82 %
Ocily3 3509 947 4456 79 %
LNCaP 3607 860 4467 81 %
MCF10A 3511 898 4409 80 %
Total 20744 5014 25758 81 %

Statistical tests and thresholds on fold change are commonly used for the identification of altered gene expression by microarray assays. Hence, we estimated the statistical significance of differential expression of each RNA from the HUR by one sample Student-t test for a change from ratio of 1. Comparison between platforms using expression values significant at p < 0.05 shows concordance in direction of 93%–98% (Table 3 – no threshold). At the 1.5 and 2-fold threshold level, the agreement between platforms approaches 100% indicating that for reproducible data all three platforms are highly concordant in direction.

Table 3.

Concordance between platforms using statistically significant expression ratios at p-value < 0.05 and at 1.5 and 2-fold threshold levels.1

No threshold 1.5-fold 2-fold
GEM2 vs. Operon GEM2 vs. U133A Operon vs. U133A GEM2 vs. Operon GEM2 vs. U133A Operon vs. U133A GEM2 vs. Operon GEM2 vs. U133A Operon vs. U133A

Number of comparisons2
Jurkat 1471 1678 1740 1096 1088 1220 588 614 749
L428 651 1394 750 580 1051 632 430 678 469
SUDHL 1400 1527 1707 1081 1177 1277 698 741 831
OCI-Ly3 1484 1834 1698 1285 1428 1333 814 900 903
LNCaP 1167 1170 2062 737 751 1252 369 404 696
MCF10A 1555 1429 1880 899 812 1118 405 409 559

Percent of concordance
Jurkat 97% 96% 98% 98% 99% 100% 99% 99% 100%
L428 96% 96% 98% 98% 98% 99% 99% 99% 100%
SUDHL 95% 97% 98% 97% 98% 99% 99% 99% 100%
OCI-Ly3 94% 96% 96% 95% 98% 98% 98% 99% 99%
LNCaP 93% 95% 96% 97% 98% 99% 99% 100% 100%
MCF10A 94% 95% 96% 98% 98% 99% 99% 99% 100%

Total number of comparisons
7728 9032 9837 5678 6307 6832 3304 3746 4207
Total number of concordances
7334 8650 9540 5509 6191 6755 3257 3719 4190
Percent agreement
94.9% 95.8% 97.0% 97.0% 98.2% 98.9% 98.6% 99.3% 99.6%
Percent of data used3
54.0% 57.5% 60.4% 39.7% 40.2% 42.0% 23.1% 23.9% 25.8%

1GEM2: Incyte GEM2 arrays; Operon: Operon V2 arrays; U133A: Affymetrix Human Genome U 133A GeneChip arrays.

2Comparisons between two platforms were done only when the expressions of both platforms met the p-value and threshold criteria.

3Fraction of common expressions between two platforms to the total number of expressions found at p < 0.05 in both platforms.

Correlation between platforms

The scatter plots shown in Figures 2a–c indicate graphically the correlation between the platforms for Jurkat RNA. Values of r for all platforms and all cell lines are given in Table 4. The values ranged from 0.7 to 0.8. Operon and Affymetrix were better correlated than were Operon and Incyte. The values were intermediate for the relationship between Incyte and Affymetrix. Figures 2d–f and Table 5 indicate that the correlation coefficients between replicates within the same platform are closer, as expected, when compared to the correlations between platforms. In general, however, there was reasonably good concordance among the platforms.

Figure 2.

Figure 2

a-f. Scatter plot analysis to determine correlation coefficients between and within platforms using Jurkat RNA as an example. Correlations for all cell lines are given in Table 4. (a) Operon versus Incyte (b) Affymetrix versus Incyte (c) Affymetrix versus Operon (d) GEM2 versus GEM2 replicate correlation (e) Operon versus Operon (f) HG-U133A versus HG-U133A

Table 4.

Cross platform correlation coefficients. Pearson correlation coefficients are given for each platform pair and cell line, calculated over the genes common to all platforms. Values were obtained from scatter plots as shown in Figure 2a-c.

Platform Jurkat L428 SUDHL OCI-Ly3 LNCaP MCF10A Median
Incyte/Operon 0.727 0.707 0.708 0.724 0.710 0.708 0.709
Incyte/Affy 0.767 0.777 0.781 0.780 0.741 0.744 0.772
Operon/Affy 0.813 0.784 0.783 0.790 0.796 0.782 0.787

Table 5.

Median correlation coefficients of replicates within same platform. Calculations and values obtained as in Table 4.

Platform Jurkat L428 SUDHL OCI-Ly3 LNCaP MCF10A
GEM2 0.859 0.919 0.902 0.873 0.827 0.845
Operon V2 0.916 0.805 0.849 0.828 0.951 0.928
HG-U133A 0.956 0.957 0.960 0.952 0.963 0.954

Principal Component Analysis (PCA)

A projection on the first three principal components, which together explain 48.8 % (21%, 14%, and 13%) of the total variance, is shown in Figure 3. Close clustering of the cell samples is observed in this projection, indicating appreciable agreement among array platforms.

Figure 3.

Figure 3

Principal Component Analysis (PCA) of the three microarray platforms and six cell lines using expression of the 3186 genes with signals above background.

"Correlation of Correlations" analysis

The global concordance of the three platforms across all of the cell lines was estimated by calculating the "correlation of correlations" coefficient [10,11]. As seen in Figure 4a–c, the correlations for the three platforms across all cells lines were quite good. The Pearson correlation of correlation coefficients was 0.965 between Operon and Incyte, 0.995 between Affymetrix and Incyte, and 0.956 between Operon and Affymetrix.

Figure 4.

Figure 4

a-c. Correlation of correlations of platforms for all cell lines. Correlation values R for each pair of platforms are given in the figures. (a) Operon versus Incyte (b) Affymetrix versus Incyte (c) Affymetrix versus Operon.

Clustered Image Map (CIM) visualization and analysis [12]

We used hierarchical clustering to demonstrate graphically the relationships among platforms, among cell lines, and among genes. 909 genes expressed at two times background or more in at least two of the six cell lines were included in the analysis. The resulting CIM ("heat map") is shown in Figure 5a–b. All three platforms cluster together for all six cell lines, as one would wish to find, and almost all of the gene expression values show reasonable concordance. Only a few exceptions can be seen in the cluster shown in Figure 5b. Some of the mismatches may be due to simple errors in gene identification, rather than to the technologies of the platforms. The Incyte library is guaranteed by the manufacturer to be only 90% correct, and an unknown percentage of the Operon and Affymetrix oligonucleotides may have been designed on the basis of incorrect sequences in the public databases. Indeed, we found one oligonucleotide in the Operon set that was apparently designed from an EST sequence that has since been withdrawn from the UniGene database (see RT-PCR studies below). In any case, the concordance is quite high across all platforms with this method of analysis as well as with the others.

Figure 5.

Figure 5

a-b. Clustered image maps showing patterns of expression relationship among genes, platforms, and cell lines. The axes were ordered by hierarchical clustering using an uncentered correlation and the average linkage algorithm for 909 genes expressed at a two-fold or greater level in at least two of the six cell lines. (a) Clustering of all 909 genes (b) A subcluster of 41 genes to show correct clustering and congruence of expression values. As indicated by the cluster trees, all three platforms gave essentially the same relationships among the six cell lines.

Quantitative real-time RT-PCR

In a pilot study with the three platforms, we compared and contrasted gene expression values for only the cell lines MCF10A and LNCaP. RT-PCR data for twelve genes are shown in Figure 6. Most of the values are in reasonable agreement except that there are differences in the magnitudes of the expression ratios. As found in other studies, the RT-PCR values are generally higher, probably because ratios are "flattened" with the microarray platforms. Affymetrix ratios are sometimes higher, but that may simply reflect the method of quantitation used in their analysis. The cDNA array ratios are generally lower than those from other platforms. Because the cDNA fragments are longer and double-stranded, they are more prone to non-specific hybridization and can cross-hybridize more easily to related sequences. These characteristics of the probes may result in higher background signal and concomitant reduction in dynamic range of the ratios. In general, we have found that the long oligonucleotide arrays have a larger dynamic range than the do the cDNA arrays.

Figure 6.

Figure 6

Quantitative real-time RT-PCR analysis of 12 genes matched for direction of expression relative to the reference RNA for all three platforms. Log2 ratios are given in table below the graph. This example is a comparison between LnCaP and MCF-10A.

For further RT-PCR analysis, we chose a set of ten genes to test the accuracy of the three array platforms for all six cell lines. Those genes were chosen because there appeared to be a discrepancy among platforms in the direction of their ratios (i.e., whether they ratios were greater or less than unity). The results are shown in Figures 7a–f. Of special interest was gene ETR101, in which the Operon array was in disagreement across all cell lines. Further inquiry revealed that the sequence had been found to be incorrect and had been removed from the UniGene database. Since the oligonucleotide had been designed from the incorrect sequence, it is not surprising that it gave a different value. Other discrepancies may be due to similar sequence errors, as even the most up-to-date databases are still being corrected and modified. In the case of AGL, the RT-PCR assay is in disagreement in several cases with two out of three of the array platforms; it appears to demonstrate an upregulation of the mRNA, whereas the arrays, with the exception of Incyte, point to a downregulation. Although RT-PCR is supposed to be the "gold standard" for measuring gene expression, this result shows that caution is indicated in interpreting results with even the PCR technology.

Figure 7.

Figure 7

a-f. Quantitative RT-PCR analysis of 10 mismatched genes in the six cells lines for all three platforms. (a) MCF10A, (b) LnCaP, (c) OCI-Ly3, (d) Jurkat, (e) SUDHL-6 and (f) L428.

Discussion

The purpose of this study was to compare and contrast the three major microarray platforms, with the goal of qualifying the long oligonucleotide platform for general use in our laboratories. Our principal findings were that the magnitude of any particular expression ratio may differ from one platform to the other but that the "direction" of gene expression difference for genes with sufficient intensity of signal appears to be well correlated across platforms. The differences in apparent magnitude of expression were not unexpected. The platforms differ widely in many characteristics, including size of targets, number of targets, concentration of targets, labeling protocol, and quantitation algorithms. Nevertheless, the overall concordance of the three platforms was reasonably good, and one should be able to compare experimental data between and among the different array types. That is perhaps not surprising if one considers microarrays simply as miniaturized, multiplexed dot blots.

A survey of the literature on platform comparisons reveals a mix of results. Several studies suggest disagreement in expression between platforms [13-20], and several demonstrate agreement [11,21-34]. The explanation for the discrepancies among these reports is not altogether clear. However, we think the following points should be remembered when designing such studies:

The same RNA templates should be used throughout the entire experiment

RNA preparations from similar, but non-identical, biopsy samples can yield dissimilar results [35], and RNA from different versions of the same cell line can yield widely different expression profiles [36,37].

Only genes common to all platforms should be used in the analysis

That may seem an obvious requirement, but it is not always easy to meet in practice. For example, careful study of sequences present in various cDNA arrays indicates that 20–30% of spots may contain the wrong clone or a misidentified one [10,14,38-40]. A similar situation exists for the short oligonucleotide platform (Affymetrix) because more than 19% of the sequences have been reported not to correspond to the appropriate mRNA Reference Sequence [41,42]. In these studies, measurements of cross-platform consistency were significantly improved when only sequence-matched genes were used. Similarly, discrepant results in studies using cDNA and Affymetrix platforms could be explained by errors in gene sequences [43]. The percentage of incorrect or misidentified sequences in the long oligonucleotide libraries is unknown, but we appear to have found one sequence in error during our own RT-PCR studies. Overall, then, significant disagreement in expression ratios among platforms may be due to sequence errors, not to intrinsic differences among array systems.

Only spots with signals significantly above background (and that pass stringent quality-control filters) should be used in the comparisons

With most high-density arrays, a large proportion of the genes can be expected to have signals near background, as probably fewer than half of all human transcripts are expressed in any particular cell type or tissue [44]. Although stringent filtering decreases the number of measurements included in the analysis, the outcome will be more meaningful.

When comparing results from the three platforms, the magnitudes of ratios were often quite different, but there was generally good agreement in the direction of differences in expression (Figs. 6 &7, Tables 2 &3). Thus, it may be less productive to correlate absolute changes in expression than it is to look for agreement in direction.

Overall, the two oligonucleotide platforms were the most concordant pair. Possible reasons are (i) that the array targets are single stranded, all of the same size (25-mer or 70-mer), with approximately the same melting temperature; (ii) the array elements have a much higher molarity of gene-specific sequences than do the cDNA arrays; (iii) that oligonucleotides tend to be more specific in terms of sequence and less prone to cross-hybridization than are cDNAs.

Conclusion

As the efficiency and economy of oligonucleotide arrays improves, they will probably become the platforms of choice for gene expression analysis, replacing the cDNA type entirely. Long-oligonucleotide arrays are being produced by ink-jet [6,45] and pin-spotting methods [26,27,31]. In these studies, where experiments specifically compared long-oligonucleotide arrays with the more "standard" platforms, correlations were good, and the long-oligonucleotide arrays performed as well as, or better than, the cDNA or short oligonucleotide variety. The data reported here confirm and extend those results, with the added advantage of comparing all three major platforms at one time and in the same place – something that, to our knowledge, has not been done before. As a note of caution, however, we have used materials from three commercial array platforms, and our results and conclusions may not necessarily translate to other platforms and manufacturers.

Since this study began, many articles have appeared reporting the "meta-analysis" of microarray data from unrelated laboratories using several different array platforms [46-54]. Those studies have reported useful clinical and diagnostic findings when the data were stringently filtered before analysis. Eventually, standardization and simplification of the systems may lead to a situation in which only one or two robust methods are used in all laboratories, with a concomitant improvement in the accuracy of gene expression data.

Methods

Experimental design

Three array platforms were tested. Incyte cDNA arrays and Operon long oligonucleotide (70-mer) arrays were printed in house, and Affymetrix 25-mer HG U133A arrays were purchased from the manufacturer. The cDNA and long oligonucleotide arrays were assayed in quadruplicate, two each of red/green and green/red for dye "flips" (reverse fluor experiments) to help eliminate dye bias (except for L428 that had 3 replicates and OCI-Ly3 with 5 replicates). The Affymetrix arrays were tested in duplicate. RNA preparations from six cell lines were tested with each platform using a universal reference RNA (Stratagene) as the standard.

Cell lines and RNAs

Cell lines were grown and RNA isolated at the core Gene Expression Laboratory, NCI-Frederick. MCF10A (benign mammary epithelial), LNCaP (prostate carcinoma), Jurkat (T-cell lymphoma), SUDHL6 (germinal center B-cell like diffuse large B-cell lymphoma), OCI-Ly3 (activated B-cell like diffuse rare B-cell lymphoma and L428 (Hodgkin's lymphoma) were grown under standard conditions [55], and RNA was isolated from the cells using TriReagent following the manufacturer's protocol (Molecular Research Center, Inc., Cincinnati, OH). Integrity of the RNA was confirmed by analysis with the Agilent 2100 Bioanalyzer (Palo Alto, CA) using the RNA 6000 LabChip® kit. For use as the index standard, Human Universal Reference RNA (HUR RNA) was purchased from Stratagene (La Jolla, CA).

Preparation of cDNA and oligonucleotide arrays

Arrays with 10,000 cDNAs were prepared from ready-to-print UniGEM2 libraries obtained from Incyte, Inc. (Wilmington, DE). Version 2.0 libraries containing 22,000 oligonucleotides of 70 bases in length were obtained from Operon, Inc. (Alameda, CA). Arrays were printed by standard protocols on Corning Ultra-GAPS II slides (Corning, NY) using a GeneMachine® (San Carlos, CA) instrument. cDNAs were suspended at a concentration of 100 μg/ml and oligonucleotides at 25 μM in 3XSSC buffer, and the arrays were printed using SMP3 pins from Telechem International (Sunnyvale, CA). The spotted nucleic acids were fixed to the slides using protocols supplied by the manufacturers. The 25-mer oligonucleotide HG U133A Genechip® arrays were purchased from Affymetrix, Inc (Santa Clara, CA).

Labeling and purification of targets

Labeled cDNAs from cell samples for hybridization to the long-oligonucleotide and cDNA arrays were synthesized and labeled by the indirect amino-allyl method, using reagents and protocols supplied by the manufacturer. For cDNA synthesis, we used Stratascript reagents (Stratagene, La Jolla, CA) and Cy3 and Cy5 fluorophore amino-allyl reagents from Amersham (Piscataway, NJ). Twenty micrograms of total RNA was used for each synthesis. Labeled cDNA targets were purified using Minelute purification kits (Qiagen, Valencia, CA). cRNA targets for the Affymetrix arrays were synthesized, labeled, and purified according to vendor's (Affymetrix) instructions. Briefly, 10 μg of total RNA was used to make double-stranded cDNA using reagents and protocols obtained from Invitrogen (Carlsbad, CA). Linear amplification was carried out by a modification of the Eberwine T7 method [56], and biotin was incorporated into the cRNA using the Enzo High Yield RNA Transcript labeling Kit (EnzoDiagnostics, Farmingdale, NY).

Hybridization and washing of arrays

The cDNA and long-oligonucleotide microarrays were prehybridized in 40 μl of 5XSSC with 0.1% SDS and 1% BSA at 42°C for 30 minutes. The prehybridization solution was removed, and arrays were hybridized for 16 hours at 42°C in 5XSSC buffer containing Cy3/Cy5 labeled targets, 25% formamide, 0.1% SDS, 1 μg Cot-1 DNA, and 1 μg poly A RNA. The cDNA arrays were washed at room temperature in 2XSSC, 0.1% SDS for 2 minutes, 1XSSC for 2 minutes, 0.2XSSC for 2 minutes and 0.05XSSC for 1 minute. The long-oligonucleotide arrays were treated the same except that the last wash step was omitted. The slides were dried by centrifugation at 650 rpm for 3 minutes. The Affymetrix arrays were hybridized and washed using the manufacturer's protocol. The arrays were then stained with streptavidin-phycoerythrin using the standard antibody amplification protocol (GeneChip® Expression Manual, Affymetrix, Inc., Santa Clara, CA).

Array scanning and image processing

Long-oligonucleotide and cDNA arrays were scanned using an Axon 4000B scanner at 10-micron resolution. Images were processed, and signals from spotted arrays were quantitated using Genepix 3.0 software (Axon Instruments, Union City, CA). The Genepix result files, including signal, background, standard deviation, pixel statistics and quality parameters for both channels were deposited in the microarray database (mAdb) maintained by the NCI/CIT bioinformatics group [57]. The data were filtered on the basis of signal levels and spot quality. Local background values were subtracted from spot intensities to obtain signal values. Data were included if the signal-to-background ratio was ≥ 2, the signal intensity was >100, the spot diameter was between 50 and 180 microns, at least 70% of the pixels were above their standard deviation and the spot was not flagged as "bad" visually. Arrays were normalized by median-centering the logarithmic ratios so that the median ratio of all genes that passed through the filters was equal to 1. For cDNA arrays, normalized expression ratios of 9050 genes were calculated, and the same procedure was applied to long-oligonucleotide arrays for the expression of 20,799 genes. Affymetrix HG-U133A arrays were scanned with the Affymetrix GeneArray scanner at 488 nm and 3-micron resolution. The images were analyzed using Microarray Suite 5.0 software (MAS5; Affymetrix Inc., Santa Clara, CA). Cell-line to HUR expression ratios were computed by comparative analysis of MAS5 values. The data were filtered using MAS5's signal detection and change calls generated at recommended default settings. The ratios included were those that had present calls for signal detection or an increase or decrease call associated with the ratio. The filtered data contained 17,647 genes. For all statistical calculations, logarithmic values of ratios to the base 2 were used.

Determination of genes in common among all platforms

Genes were matched by UniGene cluster methods [11,58], and expression levels were compared for only the 6,430 genes common to all platforms (Table 1 and Figure 1). UniGene clusters (Homo sapiens: UniGene Build #161) of probes of all three platforms were determined by the NCI/CIT Bioinformatics group [57] using the BLAST program from the National Center for Biotechnology (NCBI, Bethesda, MD 20894). There were multiple probes for some of the UniGene clusters. This resulted in matching of two or more probes of one platform to one or more probes of another platform. All possible combinations across three platforms were considered for each UniGene cluster. One probe from each of the platforms was selected as follows. Initially, for a given combination, the replicates were averaged to obtain expression patterns of six RNAs on three platforms. The sum correlation coefficients of these three patterns to their mean pattern was determined. The combination having the highest sum was selected for further analysis. This method relies on the assumption that the probes specific for a gene yield similar expression patterns independent of the platform. The matched expression ratios will be made available at our website http://nciarray.nci.nih.gov/publications/.

Estimation of total matched versus mismatched expression values

Expression ratios for genes in common across all cell lines and platforms were determined. If the ratio of a gene was ≥ 1 or ≤ 1 for both platforms being compared, the expression was considered matched irrespective of the magnitude. Otherwise, the ratios were considered to be mismatched (i.e., in opposite directions). These values give a rough, binary indication of the correlation between platforms (Table 2). Concordance between platforms using significant expression ratios at p-value <0.05 and 1.5 to 2-fold threshold levels are given in Table 3.

Correlation of expression among all platforms

To determine how well the data from the three platforms coincided, correlation coefficients were obtained from analysis of scatter plots of the mean expression values from the three array formats. Figure 2a–c are examples of scatter plot analyses of the three platforms using data from the Jurkat cell line RNA. The boundaries for ratio values greater than two-fold are delineated by the external lines. Correlation coefficients for all three pairs of platforms for all six cell lines are listed in Tables 4 &5).

Principal Component Analysis (PCA)

The global gene expression patterns of the six cell lines in all three platforms were studied by principal component analysis (PCA) [59]. All genes (3186) with signals above background were included. Differences in signal magnitude among platforms were nulled out by normalizing the data from each to unit standard deviation. Individual platform variations were accounted for by employing unit variance. A projection on the first three principal components, which explained 48.8% (21%, 14%, and 13%) of the total variance, is shown in Fig. 3. The calculations were done using Partekpro 5.0 software (Partek Inc., St. Charles, MO)

Platform concordance by "correlation of correlations" coefficient

The global concordance of expression levels of the three platforms can be expressed in terms of the 'correlations of correlations' coefficient described previously [10,11]. To perform the computations, step 1 was calculation of the Pearson correlation coefficient across all matched genes for each of the 15 possible pairs of cell lines for each platform. Step 2 was calculation of the Pearson correlation coefficients of those correlation coefficients for the three possible ways of pairing the three platforms. The results are shown in Figures 4a–c.

Hierarchical cluster analysis and Clustered Image Maps (CIMs)

Hierarchical clustering of individual replicates (data not shown), including 3662 genes detected in 80% of the arrays revealed a grouping of RNA samples independent of the type of array platform. A set of 909 genes expressed at >two-fold levels in all platforms in at least two cell lines was used for hierarchical cluster analysis to determine how closely the genes, cell lines and platforms corresponded in their expression values. As a distance metric, we used 1-r, where r is the Pearson correlation coefficient [60]. Cluster nodes were determined using an average linkage algorithm. In the resulting CIM (heat map) [14a], up- and down-regulation with respect to the reference RNA are color-coded as red and green, respectively (Figure 5a–b).

Quantitative real-time RT-PCR

RNA preparations from each of the six cell lines and Stratagene Human Universal Reference RNA were converted into single-stranded cDNA using the Applied Biosystems High-Capacity cDNA Archive kit (ABI, Foster City, CA). Primer and probe sets were obtained as ABI Assays-on-Demand™ Gene Expression Products (TaqMAN® MGB probes, FAM™ dye-labeled) for a set of genes to be studied, as well as GAPDH and BACT, which were used as comparative controls. All quantitative PCR reactions were performed in quadruplicate, with two carried out in an ABI Prism® 7000 sequence detection system and two in a Corbett Research R-300 instrument (Corbett Research, Sidney, Australia). The results were analyzed using the "Relative Quantitation of Gene Expression" method described in ABI Prism 7700 Sequence Detection System User Bulletin #2, Rev B. An initial study comparing only two cell lines, LnCaP and MCF10A, was carried out for the three platforms. Twelve genes that matched in direction of change were chosen for Q-PCR analysis, and the results are shown in Figure 6. Subsequently, ten genes were chosen for analysis using all six cell lines and three platforms. Genes in that set were deliberately chosen for mismatched ratios to determine if any platform was in error more often than the others. The results are shown in Figures 7a–f.

Abbreviations

HUR RNA: Human Universal Reference RNA

mAdb: microarray data base

Competing interests

The author(s) declare that they have no competing interests.

Authors' contributions

DP, JG, JH, JP, JH, and RP worked on developing the long oligonucleotide microarray system and provided the raw data and initial array analysis for both the cDNA and long oligonucleotide arrays. CHK, DM and LG provided input for the long oligonucleotide development and provided the Affymetrix chip data and analysis. GVRC provided statistical analysis of microarray data for the cross platform comparisons of this study. ESK drafted the original manuscript and JW was the main critical reviewer of the manuscript. LS, JCB and JeG provided valuable input into the design of the original experiments and were crucial in support of the new array development. All authors read and approved the manuscript.

Acknowledgments

Acknowledgements

GVRC acknowledges the critical bioinformatic support provided by John Powell (NCI/CIT Bioinformatics group) for conducting BLAST runs to match the probe sequences to the UniGene clusters. The authors thank Dr. Ting Qiu and Inna Dzekunova (Advanced Technology Institute/National Cancer Institute) for conducting some of the preliminary microarray experiments with the three platforms.

Contributor Information

David Petersen, Email: petersed@mail.nih.gov.

GVR Chandramouli, Email: chandrag@mail.nih.gov.

Joel Geoghegan, Email: geoghej@mail.nih.gov.

Joanne Hilburn, Email: hilburnj@mail.nih.gov.

Jonathon Paarlberg, Email: paarlbej@mail.nih.gov.

Chang Hee Kim, Email: kimcha@mail.nih.gov.

David Munroe, Email: dmunroe@ncifcrf.gov.

Lisa Gangi, Email: gangil@mail.nih.gov.

Jing Han, Email: hanj@cber.fda.gov.

Raj Puri, Email: puri@cber.fda.gov.

Lou Staudt, Email: lstaudt@mail.nih.gov.

John Weinstein, Email: jw4i@nih.gov.

J Carl Barrett, Email: barrett@mail.nih.gov.

Jeffrey Green, Email: jegreen@nih.gov.

Ernest S Kawasaki, Email: kawasake@mail.nih.gov.

References

  1. Schena M, Shalon D, Davis RW, Brown PO. Quantitative monitoring of gene expression patterns with a complementary DNA microarray. Science. 1995;270:368–371. doi: 10.1126/science.270.5235.467. [DOI] [PubMed] [Google Scholar]
  2. Lockhart DJ, Dong H, Byrne MC, Follettie MT, Gallo MV, Chee MS, Mittmann M, Wang C, Kobayashi M, Horton H, Brown EL. Expression monitoring by hybridization to high-density oligonucleotide arrays. Nature Biotechnol. 1996;14:1675–1680. doi: 10.1038/nbt1296-1675. [DOI] [PubMed] [Google Scholar]
  3. Barrett JC, Kawasaki EK. Microarrays: the use of oligonucleotides and cDNA for the analysis of gene expression. Drug Disc Today. 2003;8:134–141. doi: 10.1016/S1359-6446(02)02578-3. [DOI] [PubMed] [Google Scholar]
  4. Hardiman G. Microarray platforms – comparisons and contrasts. Pharmacogenomics. 2004;5:487–502. doi: 10.1517/14622416.5.5.487. [DOI] [PubMed] [Google Scholar]
  5. Blanchard AP, Kaiser RJ, Hood LE. High density oligonucleotide arrays. Biosens Bioelectron. 1996;11:687–690. doi: 10.1016/0956-5663(96)83302-1. [DOI] [Google Scholar]
  6. Hughes TR, Mao M, Jones AR, Burchard J, Marton MJ, Shannon KW, Lefkowitz SM, Ziman M, Schelter JM, Meyer MR, Kobayashi S, Davis C, Dai H, He YD, Stephaniants SB, Cavet G, Walker WL, West A, Coffey E, Shoemaker DD, Stoughton DD, Stoughton R, Blanchard AP, Friend SH, Linsley PS. Expression profiling using microarrays fabricated by an ink-jet oligonucleotide synthesizer. Nature Biotechnol. 2001;19:342–347. doi: 10.1038/86730. [DOI] [PubMed] [Google Scholar]
  7. Van't Veer LJ, Dai H, van de Vijver MJ, He YD, Hart AAM, Mao M, Peterse HL, van der Kooy K, Marton MJ, Witteveen AT, Schreiber GJ, Kerkhoven RM, Roberts C, Linsley PS, Bernards R, Friend SH. Gene expression profiling predicts clinical outcome of breast cancer. Nature. 2002;415:530–536. doi: 10.1038/415530a. [DOI] [PubMed] [Google Scholar]
  8. Dudley AM, Aach J, Steffen MA, Church GM. Measuring absolute expression with microarrays with a calibrated reference sample and an extended signal intensity range. Proc Natl Acad Sci USA. 2002;99:7554–7559. doi: 10.1073/pnas.112683499. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Relogio A, Schwager C, Richter A, Ansorge W, Valcarcel J. Optimization of oligonucleotide-based DNA microarrays. Nucleic Acids Res. 2002;30:e51. doi: 10.1093/nar/30.11.e51. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Scherf U, Ross DT, Waltham M, Smith LH, Lee JK, Kohn KW, Reinhold WC, Myers TG, Andrews DT, Scudiero DA, Eisen MB, Sausville EA, Pommier Y, Botstein D, Brown PO, Weinstein JN. A cDNA microarray gene expression database for the molecular pharmacology of cancer. Nature Genetics. 2000;24:236–244. doi: 10.1038/73439. [DOI] [PubMed] [Google Scholar]
  11. Lee JK, Bussey KJ, Gwadry FG, Reinhold W, Riddick G, Pelletier SL, Nishizuka S, Szakacs G, Annereau J-P, Shankavaram U, Lababidi S, Smith LH, Gottesman MM, Weinstein JN. Comparing cDNA and oligonucleotide data: concordance of gene expression across platforms for the NCI-60 cancer cells. Genome Biol. 2003;4:R82. doi: 10.1186/gb-2003-4-12-r82. [DOI] [PMC free article] [PubMed] [Google Scholar]
  12. Weinstein JN, Myers TG, O'Connor PM, Friend SH, Fornace AJ, Kohn KW, Fojo T, Bates SE, Rubinstein LV, Anderson NL, Buolamwini JK, van Osdol WW, Monks AP, Scudiero DA, Sausville EA, Zaharevitz DW, Bunow B, Viswanadhan VN, Johnson GS, Wittes RE, Paull KD. An information-intensive approach to the molecular pharmacology of cancer. Science. 1997;275:343–349. doi: 10.1126/science.275.5298.343. [DOI] [PubMed] [Google Scholar]
  13. Kuo WP, Jenssen T-K, Butte AJ, Ohno-Machado L, Kohane IS. Analysis of matched mRNA measurements from two different microarray technologies. Bioinformatics. 2002;18:405–412. doi: 10.1093/bioinformatics/18.3.405. [DOI] [PubMed] [Google Scholar]
  14. Li J, Pankratz M, Johnson JA. Differential gene expression patterns revealed by oligonucleotide versus long cDNA arrays. Toxicological Sciences. 2002;69:383–390. doi: 10.1093/toxsci/69.2.383. [DOI] [PubMed] [Google Scholar]
  15. Kothapalli R, Yoder SJ, Mane S, Loughran TP., Jr Microarray results: how accurate are they? BMC Bioinformatics. 2002;3:22. doi: 10.1186/1471-2105-3-22. [DOI] [PMC free article] [PubMed] [Google Scholar]
  16. Rogojina AT, Orr WE, Song BK, Geisert EE., Jr Comparing the use of Affymetrix to spotted oligonucleotide microarrays using two retinal pigment epithelium cell lines. Molecular Vision. 2003;9:482–496. [PMC free article] [PubMed] [Google Scholar]
  17. Carter MG, Hamatani T, Sharov AA, Carmack CE, Qian Y, Aiba K, Ko NT, Dudekula DB, Brzoska PM, Hwang SS, Ko MSH. In situ-synthesized novel microarray optimized for mouse stem cell and early developmental expression profiling. Genome Res. 2003;13:1011–1021. doi: 10.1101/gr.878903. [DOI] [PMC free article] [PubMed] [Google Scholar]
  18. Tan PK, Downey TJ, Spitznagel EL, Jr, Xu P, Fu D, Dimitrov DS, Lempicki RA, Raaka BM, Cam MC. Evaluation of gene expression measurements from commercial microarray platforms. Nucleic Acids Res. 2003;31:5676–5684. doi: 10.1093/nar/gkg763. [DOI] [PMC free article] [PubMed] [Google Scholar]
  19. Lenburg ME, Liou LS, Gerry NP, Frampton GM, Cohen HT, Christman MF. Previously unidentified changes in renal cell carcinoma gene expression identified by parametric analysis of microarray data. BMC Cancer. 2003;3:31. doi: 10.1186/1471-2407-3-31. [DOI] [PMC free article] [PubMed] [Google Scholar]
  20. Mah N, Thelin A, Lu T, Nikolaus S, Kuhbacher T, Gurbuz Y, Eickhoff H, Kloppel G, Lehrach H, Mellgard B, Costello CM, Schreiber S. A comparison of oligonucleotide and cDNA-based microarray systems. Physiol Genomics. 2004;16:361–370. doi: 10.1152/physiolgenomics.00080.2003. [DOI] [PubMed] [Google Scholar]
  21. Kane MD, Jatkoe TA, Stumpf CR, Liu J, Thomas JD, Madore SJ. Assessment of the sensitivity and specificity of oligonucleotide (50 mer) microarrays. Nucleic Acids Res. 2000;28:4552–4557. doi: 10.1093/nar/28.22.4552. [DOI] [PMC free article] [PubMed] [Google Scholar]
  22. Taniguchi M, Miura K, Iwao H, Yamanaka S. Quantitative assessment of DNA microarrays – Comparison with Northern blot analyses. Genomics. 2001;71:34–39. doi: 10.1006/geno.2000.6427. [DOI] [PubMed] [Google Scholar]
  23. Hughes TR, Mao M, Jones AR, Burchard J, Marton MJ, Shannon KW, Lefkowitz SM, Ziman M, Schelter JM, Meyer MR, Kobayashi S, Davis C, Dai H, He YD, Stephaniants SB, Cavet G, Walker WL, West A, Coffey E, Shoemaker DD, Stoughton R, Blanchard AP, Friend SH, Linsley PS. Expression profiling using microarrays fabricated by an ink-jet oligonucleotide synthesizer. Nature Biotechnol. 2001;19:342–347. doi: 10.1038/86730. [DOI] [PubMed] [Google Scholar]
  24. Guckenberger M, Kurz S, Aepinus C, Theiss S, Haller S, Leimbach T, Panzner U, Weber J, Paul H, Unkmeir A, Frosch M, Dietrich G. Analysis of heat shock response of Neisseria meningitides with cDNA- and oligonucleotide-based DNA microarrays. J Bacteriol. 2002;184:2546–2551. doi: 10.1128/JB.184.9.2546-2551.2002. [DOI] [PMC free article] [PubMed] [Google Scholar]
  25. Yuen T, Wurmbach E, Pfeffer RL, Ebersole BJ, Sealfon SC. Accuracy and calibration of commercial oligonucleotide and custom cDNA microarrays. Nucleic Acids Res. 2002;30:e48. doi: 10.1093/nar/30.10.e48. [DOI] [PMC free article] [PubMed] [Google Scholar]
  26. Barczak A, Rodriguez MW, Hanspers K, Koth LL, Tai YC, Bolstad BM, Speed TP, Erle DJ. Spotted long oligonucleotide arrays for human gene expression analysis. Genome Res. 2003;13:1775–1785. doi: 10.1101/gr.1048803. [DOI] [PMC free article] [PubMed] [Google Scholar]
  27. Wang H-Y, Malek RL, Kwitek AE, Greene AS, Luu TV, Behbahani B, Frank B, Quackenbush J, Lee NH. Assessing unmodified 70-mer oligonucleotide probe performance on glass-slide microarrays. Genome Biol. 2003;4:R5. doi: 10.1186/gb-2003-4-1-r5. [DOI] [PMC free article] [PubMed] [Google Scholar]
  28. Dabrowski M, Aerts S, Hummelen PV, Craessaerts K, De Moor B, Annaert W, Moreau Y, De Strooper B. Gene profiling of hippocampal neuronal culture. J Neurochem. 2003;85:1279–1288. doi: 10.1046/j.1471-4159.2003.01753.x. [DOI] [PubMed] [Google Scholar]
  29. Bloom G, Yang IV, Boulware D, Kwong KY, Coppola D, Eschrich S, Quackenbush J, Yeatman TJ. Multi-platform, multi-site, microarray-based human tumor classification. Am J Pathol. 2004;164:9–16. doi: 10.1016/S0002-9440(10)63090-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  30. Jarvinen A-K, Hautaniemi S, Edgren H, Auvinen P, Saarela J, Kallioniemi Olli-P, Monni O. Are data from different gene expression platforms comparable? Genomics. 2004;83:1164–1168. doi: 10.1016/j.ygeno.2004.01.004. [DOI] [PubMed] [Google Scholar]
  31. Lee H-S, Wang J, Tian L, Jiang H, Black MA, Madlung A, Watson B, Lukens L, Pires JC, Wang JJ, Comai L, Osborn TC, Doerge RW, Chen ZJ. Sensitivity of 70-mer oligonucleotides and cDNAs for microarray analysis of gene expression in Arabidopsis and its related species. Plant Biotech J. 2004;2:45–57. doi: 10.1046/j.1467-7652.2003.00048.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  32. Thompson KL, Afshari CA, Amin RP, Bertram TA, Car B, Cunningham M, Kind C, Kramer JA, Lawton M, Mirsky M, Naciff JM, Oreffo V, Pine PS, Sistare FD. Identification of platform-independent gene expression markers of cisplatin nephrotoxicity. Environ Health Perspect. 2004;112:488–494. doi: 10.1289/ehp.6676. [DOI] [PMC free article] [PubMed] [Google Scholar]
  33. Ulrich RG, Rockett JC, Gibson GG, Pettit SD. Overview of an interlaboratory collaboration on evaluating the effects of model hepatotoxicants on hepatic gene expression. Environ Health Perspect. 2004;112:423–427. doi: 10.1289/ehp.6675. [DOI] [PMC free article] [PubMed] [Google Scholar]
  34. Parmigiani G, Garrett-Mayer ES, Anbazhagan , Gabrielson E. A cross-study comparison of gene expression studies for the molecular classification of lung cancer. Clin Cancer Res. 2004;10:2922–2927. doi: 10.1158/1078-0432.ccr-03-0490. [DOI] [PubMed] [Google Scholar]
  35. Catherino WH, Segars JH. Microarray analysis in fibroids: which gene list is correct? Fertil Steril. 2003;80:293–294. doi: 10.1016/S0015-0282(03)00958-0. [DOI] [PubMed] [Google Scholar]
  36. Nugoli M, Chuchana P, Vendrell J, Orsetti B, Ursule L, Nguyen C, Birnbaum D, Douzery EJP, Cohen P, Theillet C. Genetic variability in MCF-7 sublines: evidence of rapid genomic and RNA expression profile modifications. BMC Cancer. 2003;3:13. doi: 10.1186/1471-2407-3-13. [DOI] [PMC free article] [PubMed] [Google Scholar]
  37. Freedland SJ, Pantuck AJ, Paik SH, Zisman A, Graeber TG, Eisenberg D, McBride WH, Nguyen D, Tso C-L, Belldegrun AS. Heterogeneity of molecular targets on clonal cancer lines derived from a novel hormone-refractory prostate cancer tumor system. The Prostate. 2003;55:299–307. doi: 10.1002/pros.10226. [DOI] [PubMed] [Google Scholar]
  38. Ross DT, Scherf U, Eisen MB, Perou CM, Rees C, Spellman P, Iyer V, Jeffrey SS, Van de Rijn M, Waltham M, Pergamenschikov A, Lee JCF, Lashkari D, Shalon D, Myers TG, Weinstein JN, Botstein D, Brown PO. Systematic variation in gene expression patterns in human cancer cell lines. Nature Genetics. 2000;24:227–235. doi: 10.1038/73432. [DOI] [PubMed] [Google Scholar]
  39. Halgren RG, Fielden MR, Fong CJ, Zacharewski TR. Assessment of clone identity and sequence fidelity for 1189 IMAGE cDNA clones. Nucleic Acids Res. 2001;29:582–588. doi: 10.1093/nar/29.2.582. [DOI] [PMC free article] [PubMed] [Google Scholar]
  40. Taylor E, Cogdell D, Coombes K, Hu L, Ramdas L, Tabor A, Hamilton S, Zhang W. Sequence verification as quality-control step for production of cDNA arrays. Biotechniques. 2001;31:62–65. doi: 10.2144/01311st01. [DOI] [PubMed] [Google Scholar]
  41. Mecham BH, Klus GT, Strovel J, Augustus M, Byrne D, Bozso P, Wetmore DZ, Mariani TJ, Kohane IS, Szallasi Z. Sequence-matched probes produce increased cross-platform consistency and more reproducible biological results in microarray-based gene expression measurements. Nucleic Acids Res. 2004;32:e74. doi: 10.1093/nar/gnh071. [DOI] [PMC free article] [PubMed] [Google Scholar]
  42. Mecham BH, Wetmore DZ, Szallasi Z, Sadovsky Y, Kohane I, Mariani TJ. Increased measurement accuracy for sequence-verified microarray probes. Physiol Genomics. 2004. [DOI] [PubMed]
  43. Goodsaid FM, Smith RJ, Rosenblum Quantitative PCR deconstruction of discrepancies between results reported by different hybridization platforms. Environ Health Perspect. 2004;112:456–459. doi: 10.1289/ehp.6695. [DOI] [PMC free article] [PubMed] [Google Scholar]
  44. Jongeneel CV, Iseli C, Stevneson BJ, Riggins GJ, Lal A, Mackay A, Harris RA, O'Hare MJ, Neville AM, Simpson AJG, Strausberg RL. Comprehensive sampling of gene expression in human cell lines with massively parallel signature sequencing. Proc Natl Acad Sci USA. 2003;100:4702–4705. doi: 10.1073/pnas.0831040100. [DOI] [PMC free article] [PubMed] [Google Scholar]
  45. Carter MG, Hamatami T, Sharov AA, Carmack CE, Qian Y, Aiba K, Ko NT, Dudekula DB, Brzoska PM, Hwang SS, Ko MSH. In situ-synthesized novel microarray optimized for mouse stem cell and early developmental expression profiling. Genome Res. 2003;13:1011–1021. doi: 10.1101/gr.878903. [DOI] [PMC free article] [PubMed] [Google Scholar]
  46. Rhodes DR, Barrette TR, Rubin MA, Ghosh D, Chinnaiyan AM. Meta-analysis of microarrays: Interstudy validation of gene expression profiles reveals pathway dysregulation in prostate cancer. Cancer Res. 2002;62:4427–4433. [PubMed] [Google Scholar]
  47. Moreau Y, Aerts S, De Moor B, De Strooper B, Dabrowski M. Comparison and meta-analysis of microarray data: from the bench to the computer desk. Trends Genet. 2003;19:570–577. doi: 10.1016/j.tig.2003.08.006. [DOI] [PubMed] [Google Scholar]
  48. Wright G, Tan B, Rosenwald A, Hurt EH, Wiestner A, Staudt LM. A gene expression-based method to diagnose clinically distinct subgroups of diffuse large B cell lymphoma. Proc Natl Acad Sci USA. 2003;100:9991–9996. doi: 10.1073/pnas.1732008100. [DOI] [PMC free article] [PubMed] [Google Scholar]
  49. Ferl GZ, Timmerman JM, Witte ON. Extending the utility of gene profiling data by bridging microarray platforms. Proc Natl Acad Sci USA. 2003;100:10585–10587. doi: 10.1073/pnas.2034937100. [DOI] [PMC free article] [PubMed] [Google Scholar]
  50. Culhane AC, Perriere G, Higgins DG. Cross-platform comparison and visualization of gene expression data using co-inertia analysis. BMC Bioinformatics. 2003;4:59. doi: 10.1186/1471-2105-4-59. [DOI] [PMC free article] [PubMed] [Google Scholar]
  51. Lee HK, Hsu AK, Sajdak J, Qin J, Pavlidis P. Coexpression analysis of human genes across many microarray data sets. Genome Res. 2004;14:1085–1094. doi: 10.1101/gr.1910904. [DOI] [PMC free article] [PubMed] [Google Scholar]
  52. Bloom G, Yang IV, Boulware D, Kwong KY, Coppola D, Eschrich S, Quackenbush J, Yeatman TJ. Multi-platform, multi-site, microarray-based human tumor classification. Am J Pathol. 2004;164:9–16. doi: 10.1016/S0002-9440(10)63090-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  53. Rhodes DR, Yu J, Shanker K, Deshpande N, Varambally R, Ghosh D, Barrette T, Pandey A, Chinnaiyan AM. Large-scale meta-analysis of cancer microarray data identifies common transcriptional profiles of neoplastic transformation and progression. Proc Natl Acad Sci USA. 101:9309–9314. doi: 10.1073/pnas.0401994101. [DOI] [PMC free article] [PubMed] [Google Scholar]
  54. Wang J, Coombes KR, Highsmith WE, Keating MJ, Abruzzo LV. Differences in gene expression between B-cell chronic lymphocytic leukemia and normal B cells: a meta-analysis of three microarray studies. Bioinformatics. 2004. [DOI] [PubMed]
  55. Chen SL, Maroulakou IG, Green JE, Romano-Spica V, Modi W, Lautenberger J, Bhat NK. Isolation and characterization of a novel gene expressed in multiple cancers. Oncogene. 1996;12:741–751. [PubMed] [Google Scholar]
  56. Van Gelder RN, von Xastrow ME, Yool A, Dement DC, Barchus JD, Eberwine JH. Amplified RNA synthesized from limited quantities of heterogeneous cDNA. Proc Natl Acad Sci USA. 1990;87:1663–1667. doi: 10.1073/pnas.87.5.1663. [DOI] [PMC free article] [PubMed] [Google Scholar]
  57. Greene JM, Asaki E, Bian X, Bock C, Castillo S, Chandramouli G, Martell R, Meyer K, Ruppert T, Sundaram S, Tomlin J, Yang L, Powell J. The NCI/CIT microarray database (mAdb) system – bioinformatics for the management and analysis of Affymetrix and spotted gene expression microarrays. Proc AMIA Symp. 2003:1066. [PMC free article] [PubMed] [Google Scholar]
  58. Bussey KJ, Kane D, Sunshine M, Narasimhan S, Nishizuka S, Reinhold WC, Zeeberg B, Ajay , Weinstein JN. MatchMiner A tool for batch navigation among gene and gene product identifiers. Genome Research. 2003;4:R27. doi: 10.1186/gb-2003-4-4-r27. [DOI] [PMC free article] [PubMed] [Google Scholar]
  59. Mardia KV, Kent JT, Bibby JM. Multivariate Analysis. London Academic Press; 1979. [Google Scholar]
  60. Eisen MB, Spellman PT, Brown PO, Botstein D. Cluster analysis and display of genome-wide expression patterns. Proc Natl Acad Sci USA. 1998;95:14863–14868. doi: 10.1073/pnas.95.25.14863. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from BMC Genomics are provided here courtesy of BMC