Abstract
IgM rheumatoid factor was assayed by three routine methods: latex fixation; haemagglutination; and end point laser nephelometry in 69 patients with definite or classical rheumatoid arthritis and 58 patients with other non-rheumatoid arthropathies, selected prospectively according to the American Rheumatism Association clinical criteria. The operators of the assays were unaware of the clinical diagnoses. In the group with rheumatoid arthritis 75.4% were positive by latex fixation, 73.9% by haemagglutination, and 55.1% by nephelometry. In the group with non-rheumatoid arthropathies 10.4% were positive by latex fixation, 8.6% by haemagglutination, and 10.4% by nephelometry. Thus the simple and inexpensive latex fixation test was as good as the haemagglutination test, and both were significantly better than nephelometry in the laboratory confirmation of the clinical diagnosis of definite or classic rheumatoid arthritis (chi 2 = 5.40 and 4.56, and p less than 0.025 and less than 0.05, respectively). None of these tests was significantly better or worse than the others in producing positive results in the group with non-rheumatoid arthropathies.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Azuma T., Mizuoka K., Horikoshi A. [Sensitized blood cell agglutination test for rheumatoid factor (RAHA test)]. Ryumachi. 1973 Jan;12(4):330–336. [PubMed] [Google Scholar]
- Bampton J. L., Cawston T. E., Kyle M. V., Hazleman B. L. Measurement of rheumatoid factors by an enzyme-linked immunosorbent assay (ELISA) and comparison with other methods. Ann Rheum Dis. 1985 Jan;44(1):13–19. doi: 10.1136/ard.44.1.13. [DOI] [PMC free article] [PubMed] [Google Scholar]
- DIAGNOSTIC criteria for rheumatoid arthritis: 1958 revision by a committee of the American Rheumatism Association. Ann Rheum Dis. 1959 Mar;18(1):49–53. [PMC free article] [PubMed] [Google Scholar]
- Deaton C. D., Maxwell K. W., Smith R. S., Creveling R. L. Use of laser nephelometry in the measurement of serum proteins. Clin Chem. 1976 Sep;22(9):1465–1471. [PubMed] [Google Scholar]
- Finley P. R., Hicks M. J., Williams R. J., Hinlicky J., Lichti D. A. Rate nephelometric measurement of rheumatoid factor in serum. Clin Chem. 1979 Nov;25(11):1909–1914. [PubMed] [Google Scholar]
- Finnie A., Mason M., Muir C. Evaluation of the RAHA test for rheumatoid factor. Med Lab Technol. 1974 Oct;31(4):323–326. [PubMed] [Google Scholar]
- Knight R. K., Pritchard M. H. Nephelometry compared with differential antibody titre in routine rheumatoid factor measurements. Ann Rheum Dis. 1982 Aug;41(4):426–430. doi: 10.1136/ard.41.4.426. [DOI] [PMC free article] [PubMed] [Google Scholar]
- PLOTZ C. M., SINGER J. M. The latex fixation test. I. Application to the serologic diagnosis of rheumatoid arthritis. Am J Med. 1956 Dec;21(6):888–892. [PubMed] [Google Scholar]
- Pritchard M. H., Jobbins K. Nephelometry v differential agglutination titre in the measurement of rheumatoid factors. J Clin Pathol. 1981 Apr;34(4):396–399. doi: 10.1136/jcp.34.4.396. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Roberts-Thomson P. J., McEvoy R., Langhans T., Bradley J. Routine quantification of rheumatoid factor by rate nephelometry. Ann Rheum Dis. 1985 Jun;44(6):379–383. doi: 10.1136/ard.44.6.379. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Roberts-Thomson P. J., Wernick R. M., Ziff M. Quantitation of rheumatoid factor by laser nephelometry. Rheumatol Int. 1982;2(1):17–20. doi: 10.1007/BF00541265. [DOI] [PubMed] [Google Scholar]
- Zutshi D. W., Reading C. A., Epstein W. V., Ansell B. M., Holborow E. J. FII haemagglutination test for serum antigammaglobulin factors in arthritides sero-positive and sero-negative by other tests. Ann Rheum Dis. 1969 May;28(3):289–299. doi: 10.1136/ard.28.3.289. [DOI] [PMC free article] [PubMed] [Google Scholar]