Skip to main content
The British Journal of Surgery logoLink to The British Journal of Surgery
. 1982 Apr 1;69(4):230–233. doi: 10.1002/bjs.1800690421

A simple parameter for accurate detection of severe carotid disease

R A Knox 1, P J Breslau 2, D E Strandness Jun 3,
PMCID: PMC11429101  PMID: 7074323

Abstract

The value of the ratio of the peak systolic velocity in the internal carotid artery to the end diastolic velocity in the common carotid artery in quantifying the severity of carotid arteriosclerosis has been investigated in 86 diseased vessels and 30 normal vessels. The ratio permitted gradation of disease into 60 per cent stenosis and greater with 95 per cent accuracy, 65 per cent stenosis and greater with 97 per cent accuracy and greater than 90 per cent stenosis with 100 per cent accuracy. The values for 30 normal sides studied fell below those of the 60 per cent stenosis group. The ratio has a value in predicting the severity of disease in the internal carotid artery in those with a 60 per cent stenosis and greater.

Contributor Information

R A Knox, Department of Surgery, University of Washington, School of Medicine, Seattle, Washington 98195, USA.

P J Breslau, Department of Surgery, University of Washington, School of Medicine, Seattle, Washington 98195, USA.

D E Strandness, Jun., Department of Surgery, University of Washington, School of Medicine, Seattle, Washington 98195, USA

References

  • 1. Blackshear  W M, jun., Phillips  D J, Thiele  B L  et al. : Detection of carotid occlusive disease by ultrasonic imaging and pulsed Doppler spectrum analysis. Surgery  1979, 86: 695–706. [PubMed] [Google Scholar]
  • 2. Fell  G, Phillips  D J, Chikos  P M  et al. : Ultrasonic Duplex scanning for disease of the carotid artery. Circulation  1982. (In the press.) [DOI] [PubMed] [Google Scholar]
  • 3. Blackshear  W M, jun., Phillips  D J, Chikos  P M  et al. : Carotid artery velocity patterns in normal and stenotic vessels. Stroke  1980; 11: 67–71. [DOI] [PubMed] [Google Scholar]
  • 4. Phillips  D J, Powers  J E, Eyer  M K  et al. : Detection of peripheral vascular disease using the Duplex Scanner III. Ultrasound Med Biol.  1980; 6: 205–18. [DOI] [PubMed] [Google Scholar]
  • 5. McDonald  D A: Blood Flow in Arteries. London: Arnold, 1960. [Google Scholar]
  • 6. Breslau  P J, Fell  G, Phillips  D J  et al. : The role of common carotid artery velocity patterns in the evaluation of carotid bifurcation disease. Arch. Surg.  1982. (In the press.) [DOI] [PubMed] [Google Scholar]
  • 7. Rutherford  R B, Hiatt  W R and Kreutzer  E W: The use of velocity waveform analysis in the diagnosis of carotid artery occlusive disease. Surgery  1977; 82: 695–702. [PubMed] [Google Scholar]
  • 8. Chikos  P M, Fischer  L, Hirsch  J H  et al. : Observer variability in evaluating extracranial carotid artery stenosis. Am. J. Roentgenol.  1982. (In the press.) [DOI] [PubMed] [Google Scholar]

Articles from The British Journal of Surgery are provided here courtesy of Oxford University Press