Abstract
Serum total calcium was measured in 1693 patients during a four-month period. We examined the effects of adjustment for albumin concentration on the interpretation of single measurements of serum total calcium and on the variation of series of measurements in individual patients. Markedly abnormal total calcium concentrations--2.75 mmol/l (11.0 mg/100 ml) or more, or 2.00 mmol/l (8.0 mg/100 ml) or less--were found in 115 patients, but only 24 (21%) remained markedly abnormal after adjustment for albumin. Three patients, two with malignant disease and one with primary hyperparathyroidism, had significant hypercalcaemia which was masked by hypoalbuminaemia. The serum total calcium measured on a subsequent occasion had changed 0.15 mmol/l (0.6 mg/100 ml) or more in 60 patients, but after adjustment for albumin this number was reduced to 27 (45%). The within-person standard deviation for serum total calcium was calculated in 26 patients with normal mean adjusted calcium concentrations who had had six or more sequential measurements. The mean standard deviation was 0.148 mmol/1 (0.59 mg/100 ml) and, after adjustment for albumin, this was reduced to 0.100 mmol/1 (0.40 mg/100 ml). We conclude that adjustment of serum total calcium concentration for albumin is essential to detect abnormal values and to assess changes in a value.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- DENT C. E. Some problems of hyperparathyroidism. Br Med J. 1962 Dec 1;2(5317):1419–1425. doi: 10.1136/bmj.2.5317.1419. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Dent C. E., Watson L. The hydrocortisone test in primary and tertiary hyperparathyroidism. Lancet. 1968 Sep 21;2(7569):662–664. doi: 10.1016/s0140-6736(68)92509-9. [DOI] [PubMed] [Google Scholar]
- Little A. J., Williams R. B., Parker S. D., Payne R. B. The derivation of biochemical normal ranges from a hospital outpatient population. Clin Chim Acta. 1974 Nov 20;57(1):91–95. doi: 10.1016/0009-8981(74)90182-x. [DOI] [PubMed] [Google Scholar]
- Marshall R. W., Nordin B. E. Letter: Adjustment of plasma calcium measurements. Br Med J. 1974 Jun 29;2(5921):729–730. doi: 10.1136/bmj.2.5921.729-c. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pain R. W., Rowland K. M., Phillips P. J., Duncan B. M. Current "corrected" calcium concept challenged. Br Med J. 1975 Dec 13;4(5997):617–619. doi: 10.1136/bmj.4.5997.617. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Parfitt A. M. Letter: Correction of plasma calcium measurements. Br Med J. 1974 Mar 16;1(5906):520–520. doi: 10.1136/bmj.1.5906.520. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Payne R. B., Little A. J., Williams R. B., Milner J. R. Interpretation of serum calcium in patients with abnormal serum proteins. Br Med J. 1973 Dec 15;4(5893):643–646. doi: 10.1136/bmj.4.5893.643. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Payne R. B., Little A. J., Williams R. B., Milner J. R. Letter: Adjustment of plasma calcium measurements. Br Med J. 1974 Aug 3;3(5926):345–345. doi: 10.1136/bmj.3.5926.345. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pedersen K. O. On the cause and degree of intraindividual serum calcium variability. Scand J Clin Lab Invest. 1972 Oct;30(2):191–199. doi: 10.3109/00365517209081110. [DOI] [PubMed] [Google Scholar]
- Pedersen K. O. Protein-bound calcium in human serum. Quantitative examination of binding and its variables by a molecular binding model and clinical chemical implications for measurement of ionized calcium. Scand J Clin Lab Invest. 1972 Nov;30(3):321–329. doi: 10.3109/00365517209084297. [DOI] [PubMed] [Google Scholar]
- Phillips P. J., Pain R. W., Hartley T. F., Duncan B. M., Atkinson M. J. Current "corrected" calcium concept rechallenged. Clin Chem. 1977 Oct;23(10):1938–1939. [PubMed] [Google Scholar]
- Pickup J. F., Harris E. K., Kearns M., Brown S. S. Intra-individual variation of some serum constituents and its relevance to population-based reference ranges. Clin Chem. 1977 May;23(5):842–850. [PubMed] [Google Scholar]
- Pinnell A. E., Northam B. E. New automated dye-binding method for serum albumin determination with bromcresol purple. Clin Chem. 1978 Jan;24(1):80–86. [PubMed] [Google Scholar]
- Webster D., Bignell A. H., Attwood E. C. An assessment of the suitability of bromocresol green for the determination of serum albumin. Clin Chim Acta. 1974 May 31;53(1):101–108. doi: 10.1016/0009-8981(74)90357-x. [DOI] [PubMed] [Google Scholar]
- Winkel P., Statland B. E., Bokelund H. Factors contributing to intra-individual variation of serum constituents: 5. Short-term day-to-day and within-hour variation of serum constituents in healthy subjects. Clin Chem. 1974 Dec;20(12):1520–1527. [PubMed] [Google Scholar]
- Winkel P., Statland B. E., Bokelund H., Johnson E. A. Correlation of selected serum constituents: 1. Inter-individual variation and analytical error. Clin Chem. 1975 Oct;21(11):1592–1600. [PubMed] [Google Scholar]