Skip to main content
Journal of Clinical Pathology logoLink to Journal of Clinical Pathology
. 1979 Oct;32(10):1014–1018. doi: 10.1136/jcp.32.10.1014

False-positive antiglobulin tests in healthy subjects and in hospital patients.

J Freedman
PMCID: PMC1145883  PMID: 521494

Abstract

An antiglobulin reagent containing anti-IgG, -C4c, -C4d, -C3c, and -C3d was used to test red blood cells from healthy subjects and from patients in hospital. In tests read macroscopically on opal tiles, no positive reactions were found in the healthy subjects. Positive reactions were, however, observed in 7% of the hospital patients. Further tests with monospecific reagents showed the positive reactions to be due to the presence of C4d and C3d on the red cells. All patients with positive antiglobulin reactions had serious disease, in most cases associated with abnormal antibody production or abnormal immunoglobulin levels.

Full text

PDF

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Beck M. L., Hicklin B., Pierce S. R. Unexpected limitations in the use of commercial antiglobulin reagents. Transfusion. 1976 Jan-Feb;16(1):71–75. doi: 10.1046/j.1537-2995.1976.16176130839.x. [DOI] [PubMed] [Google Scholar]
  2. Beck M. L., Marsh W. L. Complement and the antiglobulin. Transfusion. 1977 Sep-Oct;17(5):529–530. doi: 10.1046/j.1537-2995.1977.17578014598.x. [DOI] [PubMed] [Google Scholar]
  3. Chaplin H., Freedman J., Hughes-Jones N. C. Quantification of antibodies to the C3d subcomponent of human C3. Immunology. 1977 Jun;32(6):1007–1015. [PMC free article] [PubMed] [Google Scholar]
  4. Chaplin H., Jr Clinical usefulness of specific antiglobulin reagents in autoimmune hemolytic anemias. Prog Hematol. 1973;8:25–49. [PubMed] [Google Scholar]
  5. DACIE J. V., CROOKSTON J. H., CHRISTENSON W. N. Incomplete cold antibodies role of complement in sensitization to antiglobulin serum by potentially haemolytic antibodies. Br J Haematol. 1957 Jan;3(1):77–87. doi: 10.1111/j.1365-2141.1957.tb05773.x. [DOI] [PubMed] [Google Scholar]
  6. Dacie J. V., Worlledge S. M. Auto-immune hemolytic anemias. Prog Hematol. 1969;6:82–120. [PubMed] [Google Scholar]
  7. Freedman J., Chaplin H., Mollison P. L. Further observations on the preparation of antiglobulin reagents reacting with c3d and c4d on red cells. Vox Sang. 1977 Jul;33(1):21–28. doi: 10.1111/j.1423-0410.1977.tb02232.x. [DOI] [PubMed] [Google Scholar]
  8. Freedman J., Mollison P. L. Preparation of red cells coated with C4 and C3 subcomponents and production of anti-C4d and anti-C3d. Vox Sang. 1976 Oct;31(4):241–257. doi: 10.1111/j.1423-0410.1976.tb04647.x. [DOI] [PubMed] [Google Scholar]
  9. Garratty G., Petz L. D. An evaluation of commercial antiglobulin sera with particular reference to their anticomplement properties. Transfusion. 1971 Mar-Apr;11(2):79–88. doi: 10.1111/j.1537-2995.1971.tb04381.x. [DOI] [PubMed] [Google Scholar]
  10. Garratty G., Petz L. D. The significance of red cell bound complement components in development of standards and quality assurance for the anti-complement components of antiglobulin sera. Transfusion. 1976 Jul-Aug;16(4):297–306. doi: 10.1046/j.1537-2995.1976.16476247049.x. [DOI] [PubMed] [Google Scholar]
  11. Issitt P. D., Issitt C. H., Wilkinson S. L. Evaluation of commercial antiglobulin sera over a two-year period. Part II. Anti-IgG and anti-IgM levels and undesirable contaminating antibodies. Transfusion. 1974 Mar-Apr;14(2):103–108. doi: 10.1111/j.1537-2995.1974.tb04499.x. [DOI] [PubMed] [Google Scholar]
  12. Lacey J. T., Cubbin M. C. An assessment of commercial broad spectrum anti-human globulin reagents available in the United Kingdom. Med Lab Sci. 1977 Jul;34(3):201–212. [PubMed] [Google Scholar]
  13. Petz L. D., Garratty G. Antiglobulin sera--past, present and future. Transfusion. 1978 May-Jun;18(3):257–268. doi: 10.1046/j.1537-2995.1978.18378205132.x. [DOI] [PubMed] [Google Scholar]
  14. Rosenfield R. E., Jagathambal Antigenic determinants of C3 and C4 complement components on washed erythrocytes from normal persons. Transfusion. 1978 Sep-Oct;18(5):517–523. doi: 10.1046/j.1537-2995.1978.18579036378.x. [DOI] [PubMed] [Google Scholar]
  15. Stratton F., Rawlinson V. I. Preparation of test cells for the antiglobulin test. J Clin Pathol. 1974 May;27(5):359–367. doi: 10.1136/jcp.27.5.359. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Pathology are provided here courtesy of BMJ Publishing Group

RESOURCES