Abstract
Counter immunoelectrophoresis using cellulose acetate as the supporting medium was used as a rapid screening test for amoebic abscess. All the sera from 40 cases gave positive results. No false positives were obtained, but the results in intestinal amoebiasis were less reliable. An attempt was made to account for discrepancies in previous reports.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Diamond L. S. Techniques of axenic cultivation of Entamoeba histolytica Schaudinn, 1903 and E. histolytica-like amebae. J Parasitol. 1968 Oct;54(5):1047–1056. [PubMed] [Google Scholar]
- Farid Z., Hassan A., Trabolsi B., Higashi G. I., Mansour N. S., Miner W. F. Hepatic amebiasis: diagnostic counterimmunoelectrophoresis and metronidazole (flagyl) therapy. Am J Trop Med Hyg. 1977 Jul;26(4):822–823. doi: 10.4269/ajtmh.1977.26.822. [DOI] [PubMed] [Google Scholar]
- Krupp I. M. Comparison of counterimmunoelectrophoresis with other serologic tests in the diagnosis of amebiasis. Am J Trop Med Hyg. 1974 Jan;23(1):27–30. doi: 10.4269/ajtmh.1974.23.27. [DOI] [PubMed] [Google Scholar]
- Mahajan R. C., Ganguli N. K., Chhabra M. B., Chitkara N. L., Chhuttani P. N. Evaluation of Serameba, counter-immunoelectrophoresis and bentonite flocculation test in rapid diagnosis of invasive amoebiasis. Indian J Pathol Microbiol. 1976 Apr;19(2):123–126. [PubMed] [Google Scholar]
- Mahajan R. C., Ganguly N. K., Chitkara N. L. Counterimmunoelectrophoresis for rapid serodiagnosis of amoebic liver abscess. Indian J Med Res. 1975 Jan;63(1):54–57. [PubMed] [Google Scholar]
- Mannweiler E., Lederer I. Immundiagnostische Ergebnisse bei der Amöbiasis. Die Leistung der Gegenstrom-Immunelektrophorese im Vergleich zu drei anderen Immuntests. Zentralbl Bakteriol Orig A. 1978 Apr;240(3):403–408. [PubMed] [Google Scholar]
- Martuscelli A., Hernández Gonzalez A., Zúiga Tellerĺa V. Evolución de la reacción de contrainmunoelectroforesis en niños con amibiasis intestinal aguda. Rev Invest Salud Publica. 1977 Apr-Jun;37(2):93–99. [PubMed] [Google Scholar]
- Sepúlveda B., Aubanel M., Landa L., Velázquez G. Avances en la técnica de contra-immunoelectroforesis para el estudio serológico de la amibiasis. Arch Invest Med (Mex) 1972;2(Suppl):363–370. [PubMed] [Google Scholar]
- Stamm W. P., Phillips E. A. A cellulose acetate membrane precipitin (CAP) test for amoebiasis. Trans R Soc Trop Med Hyg. 1977;71(6):490–492. doi: 10.1016/0035-9203(77)90141-9. [DOI] [PubMed] [Google Scholar]