Abstract
Syphilis, caused by the bacterium Treponema pallidum, is on the rise in the United States particularly among men who have sex with men. The disease is complex with varied clinical manifestations and challenges remain in the laboratory diagnostic setting because T. pallidum is noncultivable and no single test can accurately diagnose all stages of the disease. There are missed opportunities for the use of direct detection tests in primary and secondary syphilis. The increasing use of different reverse sequence algorithms for serology testing without validation in populations with varying risks for syphilis makes the interpretation of test results difficult; this has led to concerns about diagnostic errors or overtreatment. On the other hand, the traditional algorithm may miss some early primary syphilis cases, which is of concern in high-risk populations. The potential utility of rapid syphilis serology tests in different settings or populations remains to be determined. The implementation of better tests and appropriate testing algorithms together with laboratory guidelines for test use in general will lead to better diagnostic options for syphilis.
Syphilis is a disseminated acute and chronic infection caused by Treponema pallidum subspecies pallidum (hereafter T. pallidum). The laboratory diagnosis of syphilis remains a challenge because the disease has multiple stages with varied clinical manifestations and, no single test can accurately diagnose all stages. The inability to cultivate T. pallidum on routine laboratory media has hindered diagnosis and test development. The diagnosis of syphilis relies on serological and, the infrequently available, direct detection tests. Thus, serologic tests remain the mainstay for diagnosis. Laboratories are adapting the reverse sequence algorithm for serology testing without validation in some cases, leading to concerns about diagnostic errors or overtreatment of patients.1,2 Although the majority of laboratories continue to use the traditional algorithm, there are concerns about this approach missing cases of early syphilis when the nontreponemal screening test is nonreactive.3,4 The Syphilis Health Check (Trinity Biotech, US) is the only Food and Drug Administration (FDA)-cleared Rapid Syphilis Test (RST) for use in the United States, but the role of RSTs in the United States is still unclear.5
Despite penicillin being an effective first-line treatment option for syphilis, the disease continues to spread in the United States. From a laboratory perspective, this may be due, in part, to the following reasons. First, there is no single test that can accurately diagnose all stages of syphilis, and there are missed opportunities for the use of direct detection tests in early primary syphilis because nontreponemal and treponemal serological tests are insensitive and may be nonreactive in up to 47% of patients.6–10 Second, because treponemal serological tests cannot be quantified and usually stay positive for life after successful treatment and nontreponemal titers may decline slowly or remain serofast after treatment, it is difficult to distinguish between treated and new infections in high-risk individuals with a history of treated syphilis, such as men who have sex with men (MSM). Lastly, primary lesions are painless and may go unnoticed in the vagina of women and the rectum of MSM allowing the infection to be transmitted to other sex partners. This review focuses on the diagnostic and laboratory issues relating to the use of direct detection and serology tests for syphilis that were discussed at the Centers for Disease Control and Prevention (CDC) Syphilis Summit in 2016.
Direct Detection Tests for Syphilis
Unlike many other bacterial pathogens, T. pallidum cannot be grown on routine laboratory culture media. Darkfield (DF) microscopy, polymerase chain reaction (PCR), silver staining, and immunostaining (which consists of immunofluorescent staining based on the direct fluorescent antibody for T. pallidum [DFA-TP] test and immunohistochemistry [IHC]) are direct detection tests for T. pallidum. Darkfield microscopy, PCR, or immunofluorescent staining are useful tests for infectious lesions such as ulcerative lesions, erosive rashes, condyloma lata and biopsies of skin, placenta, and other organs. Darkfield microscopy relies on examining live treponemes and is a morphology and motility-based test. Silver staining is a morphology-based test, whereas both immunofluorescent staining and IHC are both immunologically and morphology-based. Polymerase chain reaction tests detect T. pallidum-specific nucleic acid sequences.
Darkfield microscopy is useful for moist lesions of primary or secondary syphilis where treponemes can be readily found. The test is generally not used on cerebrospinal fluid (CSF), lymph node aspirate, and other body fluids. Because T. pallidum is difficult to distinguish from other spirochetes in the mouth, DF is not recommended for specimens from this site.11 Darkfield microscopy is a useful point-of-care test in STD clinics especially for patients with moist primary or secondary lesions; however, successful testing relies on an adequately trained microscopist who maintains performance proficiency in the test and the ability to perform the test before motility is compromised. The sensitivity of DF on primary lesions approaches 80% compared with immunofluorescent staining,12,13 88% compared with PCR,14 and 97% versus serology15; however, each of these tests will miss cases when the other is used as a comparator in the absence of an acceptable gold standard. In 2011, the Association of Public Health Laboratories conducted a survey on STD Testing Practices in US public health laboratories (PHLs) and found that only 19% (11/58) of laboratories had DF capability. Because DF is more often done in STD clinics and emergency departments, it would be more helpful to survey these testing sites versus PHLs. The CDC supports proficiency testing of DF microscopy in settings where the test can be performed according to specifications and provides live T. pallidum for training purposes. Requests should be sent to stdlaboratoryspecim@cdc.gov.
The DFA-TP test was first described by Yobs and colleagues16 but is no longer available in the United States. Immunofluorescent detection, which is based on the DFA-TP test, uses in-house monoclonal or polyclonal antibodies to detect T. pallidum antigens in the same specimen types as DF except that they have to be fixed on a microscope slide and body fluids require centrifugation to concentrate the bacteria. A fluorescent microscope is required to read the test. Immunofluorescent detection has similar sensitivity to DF when fresh lesion material is examined and the T. pallidum antibodies are of high quality.13,17 Although monoclonal and polyclonal antibodies are available commercially, these reagents are not approved for diagnostic testing because they have either not been validated for clinical use or quality control is not performed routinely. Silver staining and IHC are 2 techniques used for observing T. pallidum in paraffin-embedded tissue sections with samples from the brain, placenta, umbilical cord, or skin (other than primary lesions) being the most frequently tested. These staining techniques are performed in clinical pathology laboratories.
There are a number of laboratory developed PCR tests for T. pallidum, based on different gene targets, but an FDA-cleared test is not available.18 In the absence of a gold standard, the sensitivity of PCR on samples from primary syphilis is about 87% compared with DF and approaches 95% versus serology.19,20 Polymerase chain reaction sensitivity in secondary syphilis ranges from 50% to 84% on specimens from mucous patches, condyloma lata, and maculopapular rash, with the lower detection rates most likely reflecting inadequate sampling of patients with skin rash.19,21
Given the unprecedented transmission of infectious syphilis in the United States, there is a lack of a sensitive test to diagnose the most infectious lesions at the primary stage thus impeding timely detection and treatment. A commercial nucleic acid amplification-based test is urgently needed for detecting T. pallidum in moist lesions of primary or secondary syphilis. Only 1 laboratory within the Association of Public Health Laboratories network reported using a PCR test for syphilis. In addition, Quest Diagnostics offers a laboratory developed test based on real-time PCR assay targeting the flagellar biosynthetic protein (FlhB) gene. The PCR has been validated for use on CSF and genital lesion swabs and has an analytical sensitivity of 100 genomic copies/mL. The Laboratory Reference and Research Branch within the Division of STD Prevention at the CDC validated a multiplex PCR for detecting T. pallidum, herpes simplex virus (HSV) 1 and 2, and Haemophilus ducreyi, the causes of genital ulcer disease (GUD) in a Clinical Laboratory Improvement Amendments (CLIA)-certified laboratory. This assay has an analytical sensitivity of 10 to 100 genomic copies per reaction.22 Since H. ducreyi is rarely encountered in the United States these days, modifying the assay to detect T. pallidum and HSV could be 1 approach to improve the etiologic diagnosis of GUD. As of December 2017, there are 12 FDA-cleared tests to detect HSV 1 and 2 genital infections in the United States. Modifying these tests to include T. pallidum detection in a GUD multiplex PCR might be a more practical and faster approach for the development of an FDA-cleared syphilis and herpes GUD PCR test.
Because T. pallidum numbers are usually lower in CSF, blood, ocular fluid, amniotic fluid, lymph node aspirate, earlobe scraping, and some tissue biopsies compared with moist lesions of primary and secondary syphilis, nucleic acid amplification tests with better sensitivity than existing PCR assays are needed for these specimen types. A study by Yang and colleagues23 showed that swabs of the oral cavity, in the absence of visible syphilitic lesions, are useful for detecting T. pallidum in MSM engaged in unprotected oral sex practices. In addition, T. pallidum has been detected in urine by PCR.24 These noninvasive specimen types increase the repertoire of samples for PCR diagnosis and should be evaluated further.
Until an FDA-approved PCR test for GUD becomes available, it is hoped that PHLs can implement the CDC CLIA-validated multiplex GUD PCR assay for testing genital lesions swabs from sexually active patients. A nucleic acid amplification test that is available at the point of care would be particularly useful for clinics with a high burden of GUD. Specimen quality is vital for accurate PCR diagnosis. Swabs, body fluids, and tissue samples should be collected and shipped appropriately for testing as described elsewhere.25 A specimen bank including samples from genital ulcers, well-defined primary and secondary lesions, blood from all stages of syphilis, CSF, ocular fluid and congenital syphilis specimens is needed for PCR validation purposes. Other innovative methods such as RNA-based assays for increased sensitivity and next-generation sequencing methods should be explored for direct detection of T. pallidum.
Serological Diagnosis of Syphilis
Serological tests for syphilis are divided into 2 categories, tests that detect treponema-specific antibodies and those that detect antibodies to lipoidal (nontreponemal) material as a result of treponemal infection. The most common nontreponemal tests in use in the United States are the rapid plasma reagin (RPR) and the Venereal Disease Research Laboratory (VDRL) test. Of the FDA-cleared treponemal antibody tests, the fluorescent treponemal antibody-absorption (FTA-ABS) uses whole T. pallidum, the T. pallidum particle agglutination assay (TP-PA) uses a T. pallidum lysate and the enzyme immunosorbent assay (EIA)-based, chemiluminescence (CIA) assays and multiplex flow immunoassays use recombinant T. pallidum antigens (eg, 15, 17, 47 kDa, recombinant T. pallidum) to detect either IgG, IgM, or both antibodies.
Nontreponemal tests detect both IgG and IgM antibodies using a complex of cardiolipin, lecithin, and cholesterol. Positive treponemal tests indicate lifetime exposure to syphilis, whereas nontreponemal tests are more reliable indicators of untreated infection. Quantitative nontreponemal test titers are used to monitor response to treatment with a treatment response in syphilis patients defined by resolution of disease manifestations, a 4-fold decline in nontreponemal titers (or a change in 2 dilutions, eg, from 1:16 to 1:4) using the same assay, or seroreversion of a nontreponemal test to a nonreactive test.26 Nontreponemal test titers usually decline after treatment and can become nonreactive with time; however, in some treated persons, nontreponemal antibodies can persist for a long period of time, a response referred to as the “serofast reaction.”26
False-positive reactions, defined as reactivity in a nontreponemal test with a negative treponemal test in conditions other than treponemal infection occur in 1% to 2% of the United States population.27 False-positive nontreponemal test results can occur in patients with advancing age, malaria, brucellosis, mononucleosis, viral hepatitis, lymphogranuloma venereum, chickenpox, viral pneumonias, tuberculosis, chancroid, systemic lupus erythematosus, human immunodeficiency virus infection, intravenous drug use, leprosy, and in pregnancy.11,25 False-positive treponemal tests can occur in patients with endemic treponematoses (yaws, bejel, pinta) and other infections caused by spirochetes, such as Lyme disease.11 False positive reactions in both nontreponemal and treponemal tests are also seen in the sera of healthy individuals, albeit rarely.1,25 The factors associated with false positives using the newer treponemal EIA, CIA and other immunoassays for screening in the reverse sequence algorithm are not well defined.28,29
Optimization of the Reverse Sequence Algorithm to Minimize Diagnostic False Positives Leading to Overtreatment
The traditional syphilis testing algorithm uses a nontreponemal test to detect untreated syphilitic infection followed by confirming with a treponemal test. With the advent of fully automated high-throughput treponemal immunoassays that are FDA-cleared for screening, reverse screening algorithms are increasingly being used in the United States. Reverse algorithms use a treponemal test (EIA, CIA, or multiplex flow immunoassay) as a screening test, followed by a nontreponemal test for reactive samples. If the nontreponemal test is negative (discordant) then a different treponemal test is recommended.26
In 2011, 11.7% (7/53) of PHLs in the United States reported using the reverse algorithm but the algorithm and testing practices appear tovary among laboratories. For example, a review conducted at 4 laboratories in New York City found that, at 2 of the laboratories, specimens that were discordant by EIA and RPR testing were retested with a different treponemal test (TP-PA or FTA-ABS); at the third lab, specimens that were reactive by both EIA and RPR were retested by TP-PA or FTA-ABS; and in the fourth lab, no further testing was done after the EIA and RPR tests.2 Implementation of algorithms that have not been validated for specific populations with varying incidence and prevalence of syphilis infection leads to confusion among clinicians regarding the interpretation of these tests and the need for a second confirmatory treponemal test in the reverse algorithm. There is also a lack of consistency in the way laboratories report results; for example, treponemal and nontreponemal results are not always reported together, which makes it difficult for clinicians to interpret results when only 1 test result is available.2
In another study, analysis of reverse screening data from several low- and high-prevalence settings in the United States showed that overall, 56.7% of reactive EIA/CIA were nonreactive by RPR and of those, 31.6% were nonreactive with a confirmatory treponemal test.29 The percentage of discordant samples that were nonreactive by TP-PA or FTA-ABS was 2.9 times greater (40.8% vs 14.1%) in the low- versus high-prevalence populations, suggesting false positive screening test results. There are several reasons for discordant results (ie, EIA or CIA positive/RPR or VDRL negative). First, this may indicate past treated syphilis because treponemal tests may remain reactive for life. Second, it may indicate early primary syphilis since treponemal antibody test may be slightly more sensitive than nontreponemal tests at this stage because treponemal antibodies can be detected before nontreponemal antibodies.8,11 Lastly, if reflex testing with a treponemal test such as TP-PA is nonreactive, then this may indicate a false-positive EIA/CIA screening test result in low-risk populations or a true positive in high-risk populations30; however, differences in performance characteristics among the treponemal screening tests and the treponemal tests used to adjudicate discordant results can also have a bearing on false or true positive results.
With the increased use of the reverse algorithm in the United States, higher rates of false positives by CIA/EIA are being seen in low prevalence settings, such as in pregnant women.31s False-positive results can lead to overtreatment, treatment concerns in pregnant women and in patients with penicillin allergies, and anxiety in both patients, their partners, and clinicians especially if in a monogamous relationship and the partner is negative or if retesting before treatment is suggested for a pregnant woman. The CDC recommends a quantitative nontreponemal test be performed if the treponemal screening test is positive to guide patient management decisions, and if the nontreponemal test is negative, then a different treponemal test (preferably one based on different antigens and a different platform than the original test such as the TP-PA) should be used to adjudicate the results of the screening treponemal test.26 More studies are needed to determine if other factors are associated with false- or true-positive treponemal antibody results, especially with the newer treponemal tests.
Optimization of Comparisons of Traditional and Reverse Algorithms Using Clinically Defined Specimens
Studies comparing the traditional and reverse testing algorithms using specimens from various stages of syphilis in high- versus low-prevalence settings in the United States and the consequent effect on patient management are lacking. Reverse algorithms may not be appropriate for all settings and treatment delay is of concern in some high incidence populations in the United States. Additional studies are needed to determine whether EIA or CIA IgM-specific screening tests may be useful in guiding patient management. A study by Jost and colleagues showed that the analytic sensitivities of 9 approved commercial treponemal tests varied considerably, suggesting that the choice of screening and second treponemal tests in the reverse algorithm can affect testing outcome.32s Ideally, the second treponemal test should have an equivalent or higher sensitivity and specificity than the initial screening test, and target a different antigen and testing platform. With respect to use of the traditional algorithm, there is concern among clinicians that this approach misses some cases of primary syphilis particularly among high-risk populations because the VDRL and RPR screening tests generate more false-negative results due to decreased sensitivity compared to treponemal screening tests.3,4,8,33s
A few reports suggest that a higher antibody index value or optical density index cutoff of the initial screening test may help to predict a reactive second treponemal test result in the reverse algorithm, which may reduce the need for the second treponemal test, especially in lower prevalence settings.34s–36s Reporting the index value cutoff may be helpful in clinical management decisions; however, use of such values may also cause confusion with respect to their interpretation. Therefore, validation of the use of these values along with clear guidelines for laboratorians and clinicians are needed.
Value of RSTs for Diagnosis of Syphilis in the United States
There are a number of RSTs being used worldwide, and RSTs are particularly promoted for settings where risk of infection is high (eg, screening in pregnancy) and where laboratory capacity is limited or results return late (so patients were lost to follow up).37s–40s Most RSTs detect only treponemal antibodies; thus, they cannot distinguish between recent and old or previously treated infections. Several RSTs have undergone quality assessments (eg, CE Mark, WHO Prequalification, Brazilian ANVISA) and might be appropriate for introduction to the United States. As of December, 2017, the Syphilis Health Check (Trinity Biotech, US) is the only FDA-cleared RST for use in the United States but published performance data of this test in the field is still limited.5 Rapid Syphilis Tests are designed for use with fingerstick blood as part of a clinic visit, and their simplicity allows performance by health providers who are not trained technologists; however, the sensitivities of a number of tests have been shown to be higher with serum.37s The performance of RST use versus laboratory-based screening algorithms needs to be evaluated in well-defined populations together with quality assurance programs in various settings, such as public and private clinics, emergency departments or urgent care clinics, and outbreak and community outreach in the United States.
CONCLUSIONS
In light of the rising incidence of syphilis in the United States, there are many missed opportunities for use of direct detection tests during early syphilis, when the disease is most infectious. Polymerase chain reaction tests and DF for T. pallidum are needed in early primary syphilis because serological tests may not yet be reactive at this stage. Few STD clinics in the United States have DF capability and no FDA-cleared PCR test is available. As more laboratories consider using the reverse algorithm for serology testing, it is imperative that they validate algorithms in their particular setting before implementation. Also, more comparative data on the 2 algorithms are needed to address concerns about the traditional algorithm missing some early primary cases. More data are needed on RSTs with regard to appropriate settings for use, interpretation of tests results, and the need for additional laboratory-based confirmatory testing.
Acknowledgements:
The author would like to express his sincere thanks to Prof. Sheila Lukehart, Dr. Cheng Y. Chen, and Dr. Gail Bolan for their helpful comments during the preparation of the manuscript.
Footnotes
Conflicts of Interest and Sources of Funding: None declared.
Supplemental digital content is available for this article. Direct URL citations appear in the printed text, and links to the digital files are provided in the HTML text of this article on the journal’s Web site (http://www.stdjournal.com).
REFERENCES
- 1.Association of Public Health Laboratories. Laboratory diagnostic testing for Treponema pallidum, Expert Consultation Meeting Summary Report, January 13–15, 2009, Atlanta, GA. Available at: https://www.aphl.org/programs/infectious_disease/std/Documents/ID_2009Jan_Laboratory-Guidelines-Treponema-pallidum-Meeting-Report.pdf#search=Laboratory%2DGuidelines%2DTreponema%2Dpallidum%2DMeeting%2DReport. Accessed March 16, 2018.
- 2.Centers for Disease Control and Prevention. Syphilis testing algorithms using treponemal tests for initial screening—four laboratories, New York City, 2005–2006. MMWR 2008; 57:872–875. [PubMed] [Google Scholar]
- 3.Mishra S, Boily MC, Ng V, et al. The laboratory impact of changing syphilis screening from the rapid-plasma reagin to a treponemal enzyme immunoassay: a case-study from the Greater Toronto Area. Sex Transm Dis 2011; 38:190–196. [DOI] [PubMed] [Google Scholar]
- 4.Knaute DF, Graf N, Lautenschlager S, et al. Serological response to treatment of syphilis according to disease stage and HIV status. Clin Infect Dis 2012; 55:1615–1622. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Peterman TA, Fakile YF. What is the use of rapid syphilis tests in the United States? Sex Transm Dis 2016; 43(3):201–203. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Dyckman JD, Gatenbein D, Wende RD, et al. Clinical evaluation of a new screening test for syphilis. Am J Clin Pathol 1978; 70(6):918–921. [DOI] [PubMed] [Google Scholar]
- 7.Falcone VH, Stout GW, Moore MB Jr. Evaluation of rapid plasma reagin (circle) card test. Public Health Rep 1964; 79:491–495. [PMC free article] [PubMed] [Google Scholar]
- 8.Creegan L, Bauer HM, Samuel MC, et al. An evaluation of the relative sensitivities of the venereal disease research laboratory test and the Treponema pallidum particle agglutination test among patients diagnosed with primary syphilis. Sex Transm Dis 2007; 34:1016–1018. [PubMed] [Google Scholar]
- 9.Gratzer B, Pohl D, Hotton AL. Evaluation of diagnostic serological results in cases of suspected primary syphilis infection. Sex Transm Dis 2014; 41:285–289. [DOI] [PubMed] [Google Scholar]
- 10.Augenbraun M, Rolfs R, Johnson R, et al. Treponemal specific tests for the serodiagnosis of syphilis. Syphilis and HIV Study Group. Sex Transm Dis 1998; 25:549–552. [DOI] [PubMed] [Google Scholar]
- 11.Larsen SA, Steiner BM, Rudolph AH. Laboratory diagnosis and interpretation of tests for syphilis. Clin Microbiol Rev 1995; 8:1–21. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Daniels KC, Ferneyhough HS. Specific direct fluorescent antibody detection of Treponema pallidum. Health Lab Sci 1977; 14:164–171. [PubMed] [Google Scholar]
- 13.Romanowski B, Forsey E, Prasad E, et al. Detection of Treponema pallidum by a fluorescent monoclonal antibody test. Sex Transm Dis 1987; 14(3):156–159. [DOI] [PubMed] [Google Scholar]
- 14.Orle KA, Gates CA, Martin DH, et al. Simultaneous PCR detection of Haemophilus ducreyi, Treponema pallidum, and herpes simplex virus types 1 and 2 from genital ulcers. J Clin Microbiol 1996; 34:49–54. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Wheeler HL, Agarwal S, Goh BT. Dark ground microscopy and treponemal serological tests in the diagnosis of early syphilis. Sex Transm Infect 2004; 80:411–414. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Yobs AR, Brown L, Hunter EF. Fluorescent antibody technique in early syphilis; as applied to the demonstration of T. pallidum in lesions in the rabbit and in the human. Arch Pathol 1964; 77:220–225. [PubMed] [Google Scholar]
- 17.Hook EW 3rd, Roddy RE, Lukehart SA, et al. Detection of Treponema pallidum in lesion exudate with a pathogen-specific monoclonal antibody. J Clin Microbiol 1985;22(2): 241–244. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Gayet-Ageron A, Lautenschlager S, Ninet B, et al. Sensitivity, specificity and likelihood ratios of PCR in the diagnosis of syphilis: a systematic review and meta-analysis. Sex Transm Infect 2013; 89: 251–256. [DOI] [PubMed] [Google Scholar]
- 19.Shields M, Guy RJ, Jeoffreys NJ, et al. A longitudinal evaluation of Treponema pallidum PCR testing in early syphilis. BMC Infect Dis 2012; 12:353. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Palmer HM, Higgins SP, Herring AJ, et al. Use of PCR in the diagnosis of early syphilis in the United Kingdom. Sex Transm Infect 2003; 79: 479–483. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Costa-Silva M, Coutinho D, Sobrinho-Simoes J, et al. Cross-sectional study of Treponema pallidum PCR in diagnosis of primary and secondary syphilis. Int J Dermatol 2018; 57:46–49. [DOI] [PubMed] [Google Scholar]
- 22.Chen CY, Ballard RC. The molecular diagnosis of sexually transmitted genital ulcer disease. Methods Mol Biol 2012; 903:103–112. [DOI] [PubMed] [Google Scholar]
- 23.Yang CJ, Chang SY, Wu BR, et al. Unexpectedly high prevalence of Treponema pallidum infection in the oral cavity of human immunodeficiency virus-infected patients with early syphilis who had engaged in unprotected sex practices. Clin Microbiol Infect 2015; 21:787. e1–787.e7. [DOI] [PubMed] [Google Scholar]
- 24.Dubourg G, Edouard S, Prudent E, et al. Incidental syphilis diagnosed by real-time PCR screening of urine samples. J Clin Microbiol 2015; 53:3707–3708. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Seña AC, Pillay A, Cox DL, et al. Treponema and Brachyspira, Human Host-Associated Spirochetes. Manual of Clinical Microbiology. 11th ed. Washington, DC: American Society of Microbiology; 2015: 1055–1081. [Google Scholar]
- 26.Workowski KA, Bolan GA. Sexually transmitted diseases treatment guidelines, 2015. MMWR Recomm Rep 2015; 64(Rr-03):1–137. [PMC free article] [PubMed] [Google Scholar]
- 27.Golden MR, Marra CM, Holmes KK. Update on syphilis: resurgence of an old problem. JAMA 2003; 290(11):1510–1514. [DOI] [PubMed] [Google Scholar]
- 28.Binnicker MJ, Jespersen DJ, Rollins LO. Direct comparison of the traditional and reverse syphilis screening algorithms in a population with a low prevalence of syphilis. J Clin Microbiol 2012; 50: 148–150. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Centers for Disease Control and Prevention. Discordant results from reverse sequence syphilis screening–five laboratories, United States, 2006–2010. MMWR 2011; 60:133–137. [PubMed] [Google Scholar]
- 30.Park IU, Chow JM, Bolan G, et al. Screening for syphilis with the treponemal immunoassay: analysis of discordant serology results and implications for clinical management. J Infect Dis 2011; 204: 1297–1304. [DOI] [PubMed] [Google Scholar]