Skip to main content
Wiley Open Access Collection logoLink to Wiley Open Access Collection
. 2022 Nov 7;11(22):2201344. doi: 10.1002/adhm.202201344

Pharmacokinetics of Intramuscularly Administered Thermoresponsive Polymers

Ondřej Groborz 1,2,3,, Kristýna Kolouchová 1,4, Jan Pankrác 5, Peter Keša 5,6, Jan Kadlec 7, Tereza Krunclová 1, Aneta Pierzynová 8, Jaromír Šrámek 8, Mária Hovořáková 8, Linda Dalecká 8, Zuzana Pavlíková 8, Petr Matouš 5, Petr Páral 5, Lenka Loukotová 2, Pavel Švec 2, Hynek Beneš 1, Lubomír Štěpánek 3, David Dunlop 2, Carlos V Melo 9, Luděk Šefc 5, Tomáš Slanina 2, Jiří Beneš 3, Sandra Van Vlierberghe 4, Richard Hoogenboom 4,, Martin Hrubý 1,
PMCID: PMC11468617  PMID: 36153823

Abstract

Aqueous solutions of some polymers exhibit a lower critical solution temperature (LCST); that is, they form phase‐separated aggregates when heated above a threshold temperature. Such polymers found many promising (bio)medical applications, including in situ thermogelling with controlled drug release, polymer‐supported radiotherapy (brachytherapy), immunotherapy, and wound dressing, among others. Yet, despite the extensive research on medicinal applications of thermoresponsive polymers, their biodistribution and fate after administration remained unknown. Thus, herein, they studied the pharmacokinetics of four different thermoresponsive polyacrylamides after intramuscular administration in mice. In vivo, these thermoresponsive polymers formed depots that subsequently dissolved with a two‐phase kinetics (depot maturation, slow redissolution) with half‐lives 2 weeks to 5 months, as depot vitrification prolonged their half‐lives. Additionally, the decrease of T CP of a polymer solution increased the density of the intramuscular depot. Moreover, they detected secondary polymer depots in the kidneys and liver; these secondary depots also followed two‐phase kinetics (depot maturation and slow dissolution), with half‐lives 8 to 38 days (kidneys) and 15 to 22 days (liver). Overall, these findings may be used to tailor the properties of thermoresponsive polymers to meet the demands of their medicinal applications. Their methods may become a benchmark for future studies of polymer biodistribution.

Keywords: biodistribution; LCST; poly(2,2‐difluoroethyl)acrylamide; poly(N,N‐diethylacrylamide); poly(N‐isopropylacrylamide); poly(N‐acryloylpyrolidine); polyacrylamide; rational polymer design


Herein, they investigate the pharmacokinetics and biodistribution of four different thermoresponsive polyacrylamides. After intramuscular administration, their polymers from muscle depots, which dissolve with biological half‐lives 2 to 20 weeks. Moreover, polymers form secondary depots in kidneys and livers with various pharmacokinetics. Finally, they correlated the pharmacokinetics of these polymers with their physico‐chemical properties toward rational polymer design for biomedical applications.

graphic file with name ADHM-11-2201344-g002.jpg

1. Introduction

Aqueous solutions of most hydrophilic polymers exhibit a lower critical solution temperature (LCST).[ 1 ] In other words, when heated above a threshold temperature (cloud point temperature, T CP), solutions of these polymers reversibly phase‐separate into two phases, one with a low polymer concentration and the other, water‐insoluble, with a high polymer concentration (“hydrogel aggregates”).[ 1 ] Thanks to this thermoswitchable behavior, these polymers have many in vitro and in vivo applications in medicine and biological research,[ 2 ] including drug‐delivery systems,[ 3 , 4 , 5 ] cell cultures,[ 6 ] and, most importantly for this study, injectable thermogelling systems.[ 7 , 8 ]

In injectable thermogelling, polymer solutions with a T CP below body temperature (but above room temperature) are injected into the body at room temperature. Upon their administration, the temperature of these polymer solutions increases above their T CP, thereby in situ forming insoluble hydrogels, which remain at the site of administration.[ 7 , 9 ] The resulting soft hydrogel depots are highly compliant,[ 10 , 11 ] do not irritate the surrounding tissues,[ 10 , 11 , 12 ] and can be used as carriers for local radiotherapy (brachytherapy),[ 13 ] pharmacotherapy,[ 14 , 15 ] photodynamic therapy,[ 16 ] immunotherapy,[ 17 ] and vaccines.[ 18 ] Furthermore, they can alter tissue growth, regeneration, and other properties,[ 19 ] they can be applied in wound dressings[ 20 , 21 ] and healing,[ 10 , 21 ] as well as in tissue engineering,[ 6 , 21 , 22 , 23 , 24 , 25 , 26 ] and they can be used as tracers for cell/ tissue tracking.[ 12 ] When co‐administered with drugs/ hormones/ DNA/RNA, their polymer aggregates incorporate these compounds and release them for weeks, and even up to months, limiting side effects and prolonging the treatment while increasing their efficacy.[ 7 , 12 , 15 , 27 , 28 , 29 , 30 ] One such thermoresponsive polymer, ReGel (OncoGel), has shown promising results in several preclinical and clinical trials.[ 31 , 32 , 33 , 34 , 35 , 36 ] Therefore, the use of thermoresponsive polymers as injectable slow‐release drug depots may bring major benefits over therapeutic approaches currently applied in medicine.

Such potential medicinal applications of thermoresponsive polymers may, however, be precluded by our limited knowledge of their fate and pharmacokinetics, particularly regarding aggregate elimination kinetics, rather than by their specific properties.[ 12 , 37 , 38 ] For example, in our previous study on intramuscularly administered poly[N‐(isopropyl)acrylamide], we demonstrated that polymer content decreased quickly for the first few days but only slowly in the following weeks and months.[ 37 ] Furthermore, intramuscularly administered polymers form secondary depots in other organs (most markedly in the liver and kidneys), which are subsequently eliminated from the body via urine and feces.[ 37 , 38 ] Our follow‐up study corroborated these results, suggested a two‐phase pharmacokinetics model, and showed that adding a non‐thermoresponsive comonomer enables fine‐tuning polymer dissolution kinetics.[ 12 ] In summary, the in vivo analysis of thermoresponsive polymers for medicinal applications must include a comprehensive long‐term pharmacokinetics biodistribution study.

Long‐term pharmacokinetics studies require imaging techniques that do not involve ionizing radiation or irritate tissues, such as nuclear magnetic resonance imaging, especially fluorine‐19 magnetic resonance imaging (19F MRI).[ 12 , 39 , 40 ] However, 19F MRI is only sensitive to polymers with a high fluorine content. Nevertheless, in vivo fluorescence (IVF) and photoacoustic (PAI) imaging have recently emerged as sensitive, non‐invasive imaging techniques for assessing the biodistribution and quantities of fluorescently labeled compounds over time.[ 41 , 42 ] These techniques are most effective when imaging compounds near the body surface of small laboratory animals because both skin and other tissues absorb a portion of the excitation and emission light.[ 41 , 42 ] The geometry of depots can also affect the signal, but both depot geometry and depth (and hence the light absorption/scattering factor) remain almost constant in long‐term depot dissolution studies. As a result, although the absolute signal in each depot may be distorted by tissue absorption, fluorescence imaging is a straightforward method for accurately assessing depot dissolution kinetics.

Considering the above, we conducted a comprehensive, long‐term in vivo biodistribution study of four thermoresponsive polyacrylamides, commonly used in biomedical research,[ 4 ] namely poly[N‐(2,2‐difluoroethyl)acrylamide] (pDFEA), poly[N‐(isopropyl)acrylamide] (pNIPAM), poly[N,N‐(diethyl)acrylamide] (pDEA) and poly[(N‐acryloyl)pyrrolidine] (pAP; Figure 1 ), with different structures but similar T CP at similar polymer concentrations.[ 1 , 43 , 44 , 45 ] More specifically, these polymers met all of the following selection criteria: i) homopolymers of polyacrylamide derivatives (because the content of a co‐monomer[ 12 ] and polymer architecture[ 46 , 47 , 48 ] can alter their physico‐chemical properties and pharmacokinetics, adding more variables to the system); ii) water‐soluble polymers whose aqueous solutions show LCST‐type thermoresponsiveness with transition temperatures close to body temperature, but above room temperature (20 °C); iii) nonreactive, biologically inert,[ 4 ] inexpensive, easy‐to‐prepare[ 49 ] and biocompatible (as defined by ISO 10 993 norm for implants[ 50 ]) polymers whose structures represent all structural motives[ 1 ] commonly found in thermoresponsive polymers (halogenated substituents, primary and secondary amides, linear and cyclic substituents). Furthermore, pAP was used as a control because its T CP lies above body temperature, thus avoiding aggregation at the site of administration, in contrast to the other three polymers. To assess molar mass effects on polymer biodistribution and pharmacokinetics, each polymer was analyzed in two molar masses (≈20 kg mol−1 and ≈35 kg mol−1; Figure 1), both of which below the glomerular cut‐off (renal threshold) to prevent their accumulation in the body.[ 38 , 51 , 52 , 53 ] For this purpose, we labeled these polymers with a fluorescent dye, injected them into the thigh muscle of mice, and tracked their biodistribution. Lastly, we compared the biodistributions of Cy7‐traced polymers with the biodistribution of free Cy7‐amine as a control.

Figure 1.

Figure 1

Chemical structures of our polymers: poly[(N‐2,2‐difluoroethyl)acrylamide] (pDFEA), poly[(N‐isopropyl)acrylamide] (pNIPAM), poly[(N,N‐diethyl)acrylamide] (pDEA), and poly[(N‐acryloyl)pyrrolidine] (pAP).

2. Results and Discussion

2.1. In Vitro Cellular Uptake of Polymers Varies with their T CP

Before performing in vivo biodistribution studies, we analyzed cellular uptake and cellular localization using Dy505‐labelled pDFEA, pNIPAM, pDEA, and pAP (Section S3, Supporting Information). To differentiate the cells and their organelles, we stained the cytoplasmatic membranes, cell nuclei and lysosomes. In line with previous research,[ 54 , 55 ] all our polymers were located inside human fibroblasts (HF) and rat mesenchymal stem cells (rMSC). However, except for pAP, their cellular uptake was not uniform, with some cells showing strong polymer staining and others only negligible or no staining within one sample (Figures 2 and S57, Supporting Information). These differences in polymer uptake can be attributed to polymer aggregation because the cell culture is maintained at 37 °C. At this temperature, all polymers phase‐separated into dehydrated polymer mesoglobules (except for pAP, whose T CP is approximately 50 °C, Table 1 ), resulting in an uneven distribution across cells as some cells had limited contact with polymer aggregates. Conversely, pAP, remained soluble at 37 °C, so all cells exposed to pAP showed similar polymer uptake. Therefore, the polymers were internalized in both rMSC (Figure 2) and HF (Figure S57, Supporting Information), but cellular uptake depended on the state of the polymers (aggregates or solution) and on the surface area of contact with the polymers.[ 56 ]

Figure 2.

Figure 2

Cellular uptake of Dy‐505‐traced polymers into rMSC as a function of time; each polymer is shown in green (Dy505), cell membranes in red (CellMask Deep red), and nuclei in blue (Hoechst 33 342).

Table 1.

Number‐average molar mass (M n), dispersity index (Đ M) and cloud point temperature (T CP) of our polymers in fetal bovine serum at c pol = 10.0 mg mL−1 and 1.25 mg mL−1,[ 43 ] and glass‐point temperatures (T g) of neat polymers. Temperatures above body temperature (37 °C) are highlighted in red

M n Đ M T CP, 10.0 mg mL −1 T CP, 1.25 mg mL −1 T g
Polymer (kg mol−1) (M w/Mn) (°C) (°C) (°C)
pDFEA F1 24.2 1.08 22.6 ± 0.1 33.9 ± 0.1 113
F2 35.1 1.03 30.1 ± 0.2 48.0 ± 0.2
pNIPAM I1 19.6 1.03 25.7 ± 0.1 33.6 ± 0.1 136
I2 30.8 1.03 24.4 ± 0.1 30.9 ± 0.0
pDEA E1 21.2 1.06 24.4 ± 0.1 35.7 ± 0.3 95
E2 31.7 1.09 25.8 ± 0.2 32.6 ± 0.2
pAP P1 17.6 1.11 56.7 ± 0.3 75.0 ± 0.8 144
P2 32.9 1.09 48.6 ± 0.1 51.2 ± 0.1

The intracellular distribution of the polymers varied considerably. On the one hand, we detected pAP in small pinocytotic vesicles[ 57 , 58 , 59 ] (0.1 to 1 µm) and in lysosomes (Figure S57, Supporting Information). On the other hand, in line with previous research,[ 54 , 55 ] the remaining polymers were found in large phagosomes[ 57 , 58 , 59 ] (0.5 to 10 µm) and lysosomes. These differences in intracellular distribution may also be explained by polymer aggregation: pAP remains soluble at incubation temperatures and can be internalized by pinocytosis (forming many small polymer‐loaded vesicles), whereas the remaining polymers that are collapsed at 37 °C can only be internalized by phagocytosis (forming few large vesicles). Nevertheless, we demonstrated that all four studied polymers are internalized into cells, albeit through different mechanisms.

Previous research has revealed that phagocyted material function as reservoirs of small molecules that slowly release their content into the cytosol and surrounding cells.[ 56 ] Additionally, phagocyted polymer aggregates can serve as drug‐, gene‐ or enzyme‐delivery systems to lysosomes for the treatment or modulation of various lysosomal storage diseases.[ 60 , 61 ] Thus, these polymers may be used in intracellular drug or enzyme delivery.

2.2. Increasing T CP Decreases the Density of Intramuscular Depots

After their injection into mice, pDFEA (F1 and F2), pNIPAM (I1 and I2), pDEA (E1 and E2), and pAP (P1 and P2) formed intramuscular depots with various depot densities (Figure 3 , depot density was described using parameter K 10, Section S5.6, Supporting Information). Initially (≈5 min after administration), all depots had similar volumes (Tables S43 to S52, Supporting Information), but they subsequently expanded due to polymer diffusion over 2 to 4 days. During this period, the polymers were partly eliminated into the bloodstream and absorbed by local cells (as shown in vitro in Section S9, Supporting Information, and ex vivo in Section S10, Supporting Information), eventually preventing further depot expansion. The polymers that were soluble at 37 °C (P1, P2, and F2,[ 62 ] T CP > 37 °C, Figure 1) formed diffuse depots over an entire side of the mice. By contrast, the polymers that collapsed at 37°C (F1, I1, I2, E1, E2; T CP < 37 °C) formed dense polymer depots, whose volumes increased only slightly because they undergo only limited diffusion (Figure 3).

Figure 3.

Figure 3

Biodistribution of our polymers (administered polymer concentration 0.10 mg µL−1; volume 5.00 µL) and Cy7‐amine on the left side of mice at various timepoints after IM administration; the intensity of each polymer is normalized to its maximum; left: field of view; an asterisk (*) indicates the approximate site of injection; middle: biodistribution of our polymers with various M n (in brackets; kg mol−1); right: fluorescence intensity scale. The images show that primary depot diffuseness depends on T CP at low polymer concentrations because polymers with a higher T CP show an increased formation of primary intramuscular depots, with non‐aggregating pAP forming diffuse intramuscular depots regardless of molar mass. By contrast, polymers with T CP well below body temperature (pNIPAM and pDEA) formed dense depots whose density increased with the molar mass. Lastly, pDFEA, whose T CP is near body temperature at low polymer concentration, formed intermediately diffuse depots.

Higher‐molar‐mass pNIPAM and pDEA exhibited lower T CP than the corresponding lower‐molar‐mass polymers. This decrease of T CP accounted for their more extensive dehydration and collapse at body temperature, even at low polymer concentrations (Table 1), thus increasing the densities of their depots. Conversely, higher‐molar‐mass pDFEA [ 62 ] had a higher T CP than its lower‐molar‐mass counterpart (Table 1), accordingly leading to lower depot density. Yet, the increased molar mass of soluble pAP had only a minor effect on the density of its intramuscular depots because both lower‐ and higher‐molar mass pAP did not aggregate at body temperature (Figure 1) and were thus free to diffuse through tissues. As assessed by a thorough histopathological examination (Sections S6 and S15, Supporting Information), all polymers showed in vivo biocompatibility in mice upon long‐term administration, causing no harm to the animals. Therefore, these polymers may be considered for human medicinal applications by selecting the corresponding molar masses and T CP (both at high and low polymer concentrations) that meet the specific demands of depot diffuseness of various local applications (brachytherapy and drug release, among others).

2.3. Polymer Collapse Prevents Signal Migration to Remote Organs

Shortly after injecting the polymer intramuscularly, we detected polymer signal on the right side of the mice (opposite to the injected muscle; Figure 4 and Figure S62, Supporting Information), primarily in the liver and kidneys. These results are in line with the findings of previous studies[ 37 , 38 , 63 , 64 , 65 , 66 ] because nanoparticles and polymers can be absorbed by the liver (predominantly by Kupffer cells[ 64 , 65 , 66 ]) and kidneys (intraglomerular mesangial cells[ 67 , 68 , 69 , 70 , 71 ]).

Figure 4.

Figure 4

Biodistribution of our polymers (administered polymer concentration 0.10 mg µL−1; volume 5.00 µL) or Cy7‐amine on the right side of mice (opposite the site of administration) at various timepoints after their intramuscular administration; the signal was normalized to absolute maxima of all polymers (normalization to maxima of each polymer is depicted in Figure S62, Supporting Information);[ 72 ] left: field of view with the positions of the kidney (K) and liver (L) areas; middle: biodistribution of our polymers with various M n (in kg per mol); right: fluorescence intensity scale.

The intensity of the polymer signal in these secondary depots increased shortly after injecting the polymer, followed by a slow decrease over the following weeks, as discussed in more detail in Section 2.4, Supporting Information. The initial increase in the signal of secondary depots may be attributed to the initial fast release of polymers from the muscle tissue to the bloodstream and to polymer absorption by cells in remote organs (liver and kidneys).

The signal intensity of secondary depots was relatively high for P1, P2, and F2 [ 62 ] but only minor for F1, I1, I2, E1, and E2 (Figure 4 and Table S89, Supporting Information). The thermoresponsiveness of these different polymers may explain their differences in secondary depot formation, that is, polymers that show no (P1 and P2) or only limited (F2) aggregation are partly eliminated from primary depots into the bloodstream before being absorbed by local cells. This blood‐dissolved polymer is then partly eliminated and absorbed by the liver and kidneys, thus forming intense secondary depots in these organs. On the contrary, the thermoresponsive polymers I1, I2, E1, E2, and F1 that collapsed at 37°C remained in the administration site, and only a minor portion of administered polymer entered the bloodstream, limiting the formation of secondary depots in remote organs. Moreover, higher‐molar‐mass pNIPAM and pDEA had a lower T CP and aggregated more extensively; consequently, their signal was weaker in secondary organ depots. Conversely, high‐molar‐mass pDFEA had a higher T CP (Table 1) and thus a stronger signal in remote organs. These results demonstrate that polymers can be selected based on their T CP, which determines the fraction that is re‐localized in remote organs, towards limiting secondary depot formation and possible side effects of their biological applications.

2.4. Polymer Vitrification Slows Down Depot Dissolution

After the initial polymer redistribution, the signal from primary muscle depot and secondary liver and kidney depots decreased in the following weeks to months, with first‐order kinetics (Table 2 , Figures S4 and S5, Supporting Information).

Table 2.

The signal intensity‐based half‐lives of primary intramuscular (t1/2,I,IM; 2 weeks for pAP and pDEA, 2 months for pNIPAM and 5 months for pDFEA) and secondary liver (t1/2,I,LIV; 14 to 22 days for all polymers) and kidney (t1/2,I,KID; 9 days for pAP, 17 to 24 days for pDEA and pNIPAM, and 38 days for pDFEA) depots of polymers varied considerably. A double dagger () mark indicates distorted data caused by an excessively intense and delocalized signal. The half‐lives of depot primary and secondary dissolution do not correlate with the T CP or molar mass of their polymers

Polym Subtype Muscle Liver Kidney
M w
t1/2,I,IM
t1/2,I,LIV
t1/2,I,KID
(kg mol–1) (d) (d) (d)
pDFEA F1 (26) 144 ± 14 20.3 ± 1.8 45.3 ± 4.1
F2 (36) 145 ± 16
pNIPAM I1 (20) 48.4 ± 2.6 14.4 ± 2.1 14.6 ± 0.9
I2 (32) 65.8 ± 3.8 18.6 ± 2.0 24.4 ± 2.8
pDEA E1 (22) 15.9 ± 1.1 17.8 ± 2.4 16.8 ± 1.2
E2 (35) 16.3 ± 1.2 15.4 ± 2.0 17.9 ± 0.4
pAP P1 (20) 17.3 ± 0.9 22.2 ± 0.9 8.0 ± 0.4
P2 (36) 16.3 ± 1.2 21.1 ± 0.9 8.8 ± 0.6
Cy7 4.8 ± 0.3 10.9 ± 1.5 8.6 ± 0.4

The intramuscular depots of the polymers differed not only in their diffuseness but also in their dissolution rates (Table 2): pDFEA and pNIPAM had significantly longer half‐lives than pDEA and pAP. Surprisingly, the biological half‐lives of the polymers in muscle depots were statistically independent of their T CP and molar masses as pDEA and pAP have similar half‐lives, but vastly different T CP (Table 1 and Section S14, Supporting Information). Accordingly, pDFEA, pNIPAM, and pDEA, which have similar T CP values, showed considerably different biological half‐lives in muscle depots.

We hypothesize that such a diversity of biological half‐lives can be attributed to polymer vitrification. Previous studies[ 73 , 74 , 75 ] have demonstrated that pNIPAM aggregates can vitrify over time, which affects the demixing and remixing kinetics of this polymer. To test this hypothesis, we studied the thermal properties of phase‐separated polymers by differential scanning calorimetry (DSC) in their 20 wt. % solutions (Section S8.3, Supporting Information). We observed signs of aggregate vitrification in pDFEA and pNIPAM at 37 °C (also in pAP but only above ≈50 °C), whereas pDEA did not form a vitrified collapsed phase. Therefore, we propose that both pDFEA and pNIPAM aggregated and vitrified inside cells, which decreased their elimination rates in comparison with pDEA and pAP.

By contrast, pAP (non‐aggregated polymer at 37 °C) and pDEA (aggregated but not vitrified) had similar dissolution rates, both of which were significantly faster than the dissolution rates of pNIPAM and pDFEA. In this context, we have previously demonstrated that pDFEA aggregates exhibit extraordinarily strong interactions with proteins,[ 43 ] which may further decrease the rate of in vivo elimination of this polymer from cells (Section S14, Supporting Information). As such, any rational design of polymers for biological applications must consider not only their depot diffuseness but also their biological half‐lives.

In line with the above, the signal of polymers with various biological half‐lives in the secondary liver and kidney depots also decreased with first‐order kinetics (Table 2). Previous research has shown that, upon cell death, the content of cells is released into urine (mesangial cells) or bile and stool (Kupffer cells) or re‐absorbed by other cells.[ 64 , 69 , 70 , 76 , 77 ] In the liver depots, the biological half‐lives of all polymers (15 to 22 days, Table 2) were similar to the lifespan of Kupffer cells (≈ 21 days[ 78 ]). This observation suggests that the half‐lives of these polymers in the liver are determined by the lifespan of Kupffer cells rather than by their physico‐chemical properties (further discussed in Section S14, Supporting Information).

In the kidney depots, in turn, the half‐lives of the polymers varied significantly, ranging from 8 to 38 days, revealing a similar trend to that observed in intramuscular depot dissolutions (pAP < pDEApNIPAM < pDFEA; Table 2, further discussed in Section S14, Supporting Information). Hence, in kidneys, the physico‐chemical properties of these polymers determine both their half‐lives and their elimination into urine by mesangial cells; their clearance is clearly not affected by the lifespan of these cells (≈ several weeks[ 79 ]). Combined, these findings highlight the importance of analyzing the formation of secondary organ depots when designing polymers with various half‐lives for medicinal applications.

2.5. Physiological Model of Polymer Pharmacokinetics

Based on the data presented above and on our previous results,[ 12 ] showing that thermoresponsive polymers bind to tissues, which slows down their dissolution kinetics, we propose here a pharmacokinetics model that describes the biodistribution of polymers in the body (Figure 5 and Section S7, Supporting Information). After their administration, the polymers form primary extracellular depots, which slowly enlarge due to diffusion, for a few days (t S, max), as a function of T CP. During this period, a fraction of the polymers (A) are absorbed into muscle cells (k EX→IN), forming primary intracellular depots, whereas the remaining polymers (1 – A) are drained via lymphatic and blood vessels into the bloodstream (k EX→B), where A is determined by the ratio of k EX→IN and sum of k EX→IN and k EX→B (because k EX→IN and k EX→B are competing processes). The primary intracellular depots slowly redissolve, releasing the polymers into the bloodstream (most likely via exocytosis[ 59 ]) for weeks and up to months (k I,IM or t1/2,I,IM). Through the blood, these polymers enter the liver and kidneys (and possibly, to a small extent, other organs), forming secondary depots therein (with variable affinities, i.e., initial signal fraction in kidneys, f KID, and liver, f LIV). Ultimately, the polymers are released from the kidneys into the urine and from the liver into the bile, thus being excreted (k KID and k LIV). Overall, these processes can be characterized by specific kinetics constants and tuned by choosing polymers (or comonomers[ 12 ]) that meet the requirements of a desired application.

Figure 5.

Figure 5

Proposed biodistribution model (A) and plot of calculated concentrations in each compartment (B), demonstrated by the biodistribution of a model polymer as a function of time.

This model is in line with previous studies, which demonstrated that such polymers can i) enter the bloodstream after intramuscular,[ 37 , 80 ] intraperitoneal,[ 63 , 80 ] or subcutaneous[ 63 , 80 ] administration, ii) form primary depots at the site of administration and secondary depots predominantly in the liver,[ 37 , 38 , 51 , 63 , 80 , 81 , 82 ] kidneys,[ 37 , 51 , 81 , 82 ] spleen,[ 38 , 51 ] among other organs, and iii) are ultimately eliminated via urine and stool (thus signal was detected in bladder and intestines).[ 37 , 38 , 63 , 81 ] Furthermore, the composition (co‐monomer content),[ 12 , 38 , 51 , 80 ] molar mass,[ 38 , 51 , 63 , 80 , 81 , 82 ] and aggregation[ 12 , 37 ] of the polymers affect their pharmacokinetics and biodistribution.

2.6. Rational Polymer Design

Lastly, we thoroughly analyzed how the properties of the polymers affect their pharmacokinetics (Section S14, Supporting Information). Our findings can be summarized into three simple rules for rational polymer design:

  • i)

    At the site of administration, polymer depot diffuseness increases with T CP . Polymers with a T CP [ 83 ] lower than body temperature form dense primary depots at the site of administration, whereas polymers with a T CP higher than body temperature form diffuse depots. In turn, the T CP of a polymer can be fine‐tuned by changing its molar mass or its content of comonomers.[ 12 ]

  • ii)

    In remote organs, the polymer content of secondary depots increases with T CP . Polymers with a T CP higher than body temperature accumulate in remote organs. The polymer content of these secondary depots increases with T CP. By contrast, polymers with a T CP lower than body temperature are barely detectable in remote organs.

  • iii)

    Polymer retention is limited by the lifespan of short‐lived cells but depends only on its physicochemical properties in long‐lived cells. In long‐lived cells (such as myocytes), polymer retention increases with (a) the vitrification of polymer aggregates and (b) the affinity of polymer aggregates to proteins (both can be studied by calorimetry). Conversely, polymers that (a) do not aggregate or (b) aggregate but do not vitrify at body temperature have similar pharmacokinetics of dissolution (half‐life of ≈16 days). In some cells (mesangial cells), polymer retention mostly depends on its T CP (Section S14, Supporting Information ). In contrast – in short‐lived cells, e.g., Kupfer cells, polymer retention is determined by the lifespan of these cells.

In conclusion, thermoresponsive polymers may have major advantages over non‐thermoresponsive polymers. Thermoresponsive polymers aggregate upon administration, effectively decreasing the dilution of the primary extracellular depot and thus the amount of polymer that is cleared into the bloodstream and that reaches the kidneys and liver (Figure 4 and Table S26, Supporting Information). Thanks to their increased retention at the site of administration, thermoresponsive polymers may considerably outperform non‐thermoresponsive polymers in some clinical applications by avoiding possible kidney‐ or liver‐related side effects, among other reasons.

3. Conclusions

In vitro, pDFEA, pNIPAM, pDEA, and pAP cellular uptake varies with T CP, and the mechanism of internalization of the polymers depends on their state (collapsed aggregates or solution) and on their surface area. In vivo, upon intramuscular administration, these polymers form depots whose density increases with dehydration and collapse, leading to a decrease in polymer diffusion rates. As such, polymers can be selected based on their T CP, which in turn can be fine‐tuned based on their molar mass, to meet the specific demands of depot diffuseness for local applications. Moreover, polymer thermoresponsiveness also determines the fraction of polymers localized in remote organs by secondary depot formation. Accordingly, their thermoresponsiveness can be used to limit or avoid possible side effects on those organs.

The intracellular depot dissolution of pDFEA, pNIPAM, pDEA, and pAP follows first‐order kinetics, albeit with different biological half‐lives. In muscles, the biological half‐lives of these polymers are highly variable (2 weeks to 5 months) and determined by their vitrification (if the T g of the partly hydrated collapsed depot is lower than body temperature) and affinity to intracellular proteins. In the liver, their half‐lives are determined by the lifespan of Kupffer cells rather than by their physico‐chemical properties. In the kidneys, conversely, their half‐lives are determined by their physico‐chemical properties (inversely correlated with polymer T CP) rather than by the lifespan of mesangial cells. Their dissolution rates can be characterized by specific kinetics constants, which enable us to choose the polymers that meet the requirements of a desired clinical application. Therefore, thermoresponsive polymers have considerable advantages over non‐thermoresponsive polymers, e.g., by providing us with the ability to tune depot densities and half‐lives and to limit side effects on kidneys and liver.

Lastly, the biocompatible fluorescent tracer Cy7 can be used for long‐term (≥250 days) in vivo polymer tracking by fluorescence imaging. In pharmacokinetics research, this approach may be applied to other polymers for determining their biodistribution and biological half‐lives. Ultimately, the physiological biodistribution model proposed herein may become a benchmark for future studies of polymer pharmacokinetics and for the rational design of polymers for brachytherapy, drug delivery, and tissue engineering, among other applications.

Conflict of Interest

O.G. is a stockholder of Bausch Health Companies Inc. (Laval, Canada), whose subsidiary licenses Visidic gel, which in turn was used in this study to prevent major side effects of anesthesia, such as keratitis sicca. The other authors have no conflict of interest to declare. No company, grant agency, or employer influenced the design of the study, its evaluation, or its conclusions.

Supporting information

Supporting Information

Supplemental Video 1

Supplemental Video 2

Supplemental Video 3

Supplemental Video 4

Supplemental Video 5

Supplemental Video 6

Supplemental Video 7

Supplemental Video 8

Supplemental Video 9

Supplemental Video 10

Supplemental Video 11

Supplemental Video 12

Supplemental Video 13

Supplemental Video 14

Supplemental Video 15

Supplemental Video 16

Supplemental Video 17

Supplemental Video 18

Supplemental Video 19

ADHM-11-2201344-s002.rar (24.2MB, rar)

Supporting Information

Supporting Information

Supporting Information

Supporting Information

Supporting Information

ADHM-11-2201344-s004.rar (10.7MB, rar)

Supporting Information

Supporting Information

Supporting Information

Supporting Information

Supporting Information

Acknowledgements

The authors thank Ing. Pavla Volešák Francová and Dr. Jan Kučka for their help with the biological experiments and MUDr. Tomáš Kučera, Ph.D. for his help with histopathological evaluation, and Ing. Tomáš Belloň for the cover art. O.G. and D.D. acknowledge the funding from the Grant Agency of Charles University, GA UK (project No. 379 321). The authors acknowledge the funding from the Technology Agency of the Czech Republic (TA ČR; grant #KAPPA TO01000074 ELECTTRA), from the Ministry of Education, Youth and Sports of the Czech Republic (grant INTER‐COST # LTC19032) and from the Czech Science Foundation (grant # 21–04166S). The ELECTTRA benefits from a EUR 1,327,180 grant from Iceland, Liechtenstein and Norway through the EEA Grants and the Technology Agency of the Czech Republic. The Center for Advanced Preclinical Imaging (CAPI) is grateful to the Large RI Project project No. LM2018129 (Czech‐BioImaging) funded by the Ministry of Education, Youth and Sports of the Czech Republic, project No. CZ.02.01./0.0./0.0./16_013/0 001775 supported by European Regional Development Fund, and the grant SVV 260 519/2021 supported by Charles University. K.K. acknowledges the financial support by Research Foundation – Flanders (FWO, Fonds Wetenschappelijk Onderzoek – Vlaanderen, project No. 1229422N). After initial online publication, a second affiliation was added for P.K. on November 16, 2022, as this was missing in the original version.

Groborz O., Kolouchová K., Pankrác J., Keša P., Kadlec J., Krunclová T., Pierzynová A., Šrámek J., Hovořáková M., Dalecká L., Pavlíková Z., Matouš P., Páral P., Loukotová L., Švec P., Beneš H., Štěpánek L., Dunlop D., Melo C. V., Šefc L., Slanina T., Beneš J., Van Vlierberghe S., Hoogenboom R., Hrubý M., Pharmacokinetics of Intramuscularly Administered Thermoresponsive Polymers. Adv. Healthcare Mater. 2022, 11, 2201344. 10.1002/adhm.202201344

Contributor Information

Ondřej Groborz, Email: ondrej.groborz@seznam.cz.

Richard Hoogenboom, Email: richard.hoogenboom@ugent.be.

Martin Hrubý, Email: mhruby@centrum.cz.

Data Availability Statement

The data that support the findings of this study are available from the corresponding author upon reasonable request.

References

  • 1. Aseyev V., Tenhu H., Winnik F. M., in Self Organized Nanostructures of Amphiphilic Block Copolymers II, (Eds: Müller A. H. E., Borisov O.), Springer, Berlin, Heidelberg: 2010, vol. 242, p. 29. [Google Scholar]
  • 2. Mano J. F., Adv. Eng. Mater. 2008, 10, 515. [Google Scholar]
  • 3. Chung J. E., Yokoyama M., Aoyagi T., Sakurai Y., Okano T., J. Controlled Release 1998, 53, 119. [DOI] [PubMed] [Google Scholar]
  • 4. Ward M. A., Georgiou T. K., Polymers 2011, 3, 1215. [Google Scholar]
  • 5. Schmaljohann D., Adv. Drug Delivery Rev. 2006, 58, 1655. [DOI] [PubMed] [Google Scholar]
  • 6. Takezawa T., Mori Y., Yoshizato K., Nat. Biotechnol. 1990, 8, 854. [DOI] [PubMed] [Google Scholar]
  • 7. Tang Y., Oak M., Mandke R., Layek B., Sharma G., Singh J., in Active Implants and Scaffolds for Tissue Regeneration, (Ed: Zilberman M.), Springer, Berlin, Heidelberg: 2011, pp. 457–479. [Google Scholar]
  • 8. Cally O., Young D. J., Loh X. J. C., in Biodegradable Thermogels, Royal Society of Chemistry, Cambridge, United Kingrom: 2018, pp 1–22. [Google Scholar]
  • 9. Ruel‐Gariépy E., Leroux J.‐C., Eur. J. Pharm. Biopharm. 2004, 58, 409. [DOI] [PubMed] [Google Scholar]
  • 10. Kopeček J., Biomaterials 2007, 28, 5185. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11. Zhu J., Marchant R. E., Expert Rev. Med. Devices 2011, 8, 607. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12. Kolouchova K., Jirak D., Groborz O., Sedlacek O., Ziolkowska N., Vit M., Sticova E., Galisova A., Svec P., Trousil J., Hajek M., Hruby M., J. Controlled Release 2020, 327, 50. [DOI] [PubMed] [Google Scholar]
  • 13. Hruby M., Kucka J., Lebeda O., Mackova H., Babic M., Konak C., Studenovsky M., Sikora A., Kozempel J., Ulbrich K., J. Controlled Release 2007, 119, 25. [DOI] [PubMed] [Google Scholar]
  • 14. Šácha P., Knedlík T., Schimer J., Tykvart J., Parolek J., Navrátil V., Dvořáková P., Sedlák F., Ulbrich K., Strohalm J., Majer P., Šubr V.­R., Konvalinka J., Angew. Chem., Int. Ed. 2016, 55, 2356. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15. Sung Y. K., Kim S. W., Biomater. Res. 2020, 24, 12. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16. Lan M., Zhao S., Liu W., Lee C. S., Zhang W., Wang P., Adv. Healthcare Mater. 2019, 8, 1900132. [DOI] [PubMed] [Google Scholar]
  • 17. Loukotová L., Kučka J., Rabyk M., Höcherl A., Venclíková K., Janoušková O., Páral P., Kolářová V., Heizer T., Šefc L., Štěpánek P., Hrubý M., J. Controlled Release 2017, 268, 78. [DOI] [PubMed] [Google Scholar]
  • 18. Pacifici N., Bolandparvaz A., Lewis J. S., Adv. Ther. 2020, 3, 2000129. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19. Chen C.‐H., Chen S.‐H., Mao S.‐H., Tsai M.‐J., Chou P.‐Y., Liao C.‐H., Chen J.‐P., Carbohydr. Polym. 2017, 173, 721. [DOI] [PubMed] [Google Scholar]
  • 20. Wu D.‐Q., Zhu J., Han H., Zhang J.‐Z., Wu F.‐F., Qin X.‐H., Yu J.‐Y., Acta Biomater. 2018, 65, 305. [DOI] [PubMed] [Google Scholar]
  • 21. Elloumi‐Hannachi I., Yamato M., Okano T., J. Intern. Med. 2010, 267, 54. [DOI] [PubMed] [Google Scholar]
  • 22. Ekerdt B. L., Fuentes C. M., Lei Y., Adil M. M., Ramasubramanian A., Segalman R. A., Schaffer D. V., Adv. Healthcare Mater. 2018, 7, 1800225. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23. Doberenz F., Zeng K., Willems C., Zhang K., Groth T., J. Mater. Chem. B 2020, 8, 607. [DOI] [PubMed] [Google Scholar]
  • 24. Van Vlierberghe S., Dubruel P., Schacht E., Biomacromolecules 2011, 12, 1387. [DOI] [PubMed] [Google Scholar]
  • 25. Scoccimarro E., Young D. J., Loh X. J., in Biodegradable Thermogels, Royal Society of Chemistry, Cambridge, United Kingrom: 2018, Vol. 5, pp. 87–101. [Google Scholar]
  • 26. Talebian S., Mehrali M., Taebnia N., Pennisi C. P., Kadumudi F. B., Foroughi J., Hasany M., Nikkhah M., Akbari M., Orive G., Dolatshahiâ Pirouz A., Adv. Sci. 2019, 6, 1801664. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27. Liechty W. B., Kryscio D. R., Slaughter B. V., Peppas N. A., Annu. Rev. Chem. Biomol. Eng. 2010, 1, 149. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28. Kim Y. J., Choi S., Koh J. J., Lee M., Ko K. S., Kim S. W., Pharm. Res. 2001, 18, 548. [DOI] [PubMed] [Google Scholar]
  • 29. Chen S., Pederson D., Oak M., Singh J., J. Pharm. Sci. 2010, 99, 3381. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30. Zentner G. M., Rathi R., Shih C., Mcrea J. C., Seo M.‐H., Oh H., Rhee B. G, Mestecky J., Moldoveanu Z., Morgan M., Weitman S., J. Controlled Release 2001, 72, 203. [DOI] [PubMed] [Google Scholar]
  • 31.Clinical studies of ReGel/OncoGel (copolymer of poly(lactide‐co‐glycolide) and poly(ethylene glycol)) showed that injectable thermogelling can provide high local concentrations of drugs (e.g., paclitaxel) while avoiding their systemic applications, decreasing the side effects of therapy.[ 35 , 36 ] Nevertheless, such an approach is ill‐suited for cancer therapy: single‐agent chemotherapy is obsolete for its low therapeutic efficacy.[ 84 , 85 ] Thus, clinical trials of ReGel/OncoGel in oncology were discontinued for their low treatment efficacy, but injectable thermogelling systems may be still used in other therapies aimed at prolonged drug release, e.g. local or systemic hormonal therapy.[ 7 ]
  • 32. Tyler B., Fowers K. D., Li K. W., Recinos V. R., Caplan J. M., Hdeib A., Grossman R., Basaldella L., Bekelis K., Pradilla G., Legnani F., Brem H., JNS 2010, 113, 210. [DOI] [PubMed] [Google Scholar]
  • 33. Elstad N. L., Fowers K. D., Adv. Drug Delivery Rev. 2009, 61, 785. [DOI] [PubMed] [Google Scholar]
  • 34. Vukelja S. J., Anthony S. P., Arseneau J. C., Berman B. S., Casey Cunningham C., Nemunaitis J. J., Samlowski W. E., Fowers K. D., Anti‐Cancer Drugs 2007, 18, 283. [DOI] [PubMed] [Google Scholar]
  • 35. Aaron DuVall G., Tarabar D., Seidel R. H., Elstad N. L., Fowers K. D., Anti‐Cancer Drugs 2009, 20, 89. [DOI] [PubMed] [Google Scholar]
  • 36. Prasad A., Young D. J., Loh X. J., in Biodegradable Thermogels, Royal Society of Chemistry, Cambridge, United Kingrom: 2018, Vol. 8, pp. 133–144. [Google Scholar]
  • 37. Kučka J., Hrubý M., Lebeda O., Appl. Radiat. Isot. 2010, 68, 1073. [DOI] [PubMed] [Google Scholar]
  • 38. Bertrand N., Fleischer J. G., Wasan K. M., Leroux J.‐C., Biomaterials 2009, 30, 2598. [DOI] [PubMed] [Google Scholar]
  • 39. Srinivas M., Heerschap A., Ahrens E. T., Figdor C. G., Vries I. J. M., Trends Biotechnol. 2010, 28, 363. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 40. Tirotta I., Dichiarante V., Pigliacelli C., Cavallo G., Terraneo G., Bombelli F. B., Metrangolo P., Resnati G., Chem. Rev. 2015, 115, 1106. [DOI] [PubMed] [Google Scholar]
  • 41. Rao J., Dragulescu‐Andrasi A., Yao H., Curr. Opin. Biotechnol. 2007, 18, 17. [DOI] [PubMed] [Google Scholar]
  • 42. Attia A. B. E., Balasundaram G., Moothanchery M., Dinish U. S., Bi R., Ntziachristos V., Olivo M., Photoacoustics 2019, 16, 100144. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 43. Kolouchová K., Lobaz V., Beneš H., De La Rosa V. R., Babuka D., Švec P., Černoch P., Hrubý M., Hoogenboom R., Petr Štěpánek P., Groborz O., Polym. Chem. 2021, 12, 5077. [Google Scholar]
  • 44. Qiu X.‐P., Winnik F. M., Macromol. Rapid Commun. 2006, 27, 1648. [Google Scholar]
  • 45.Use of International Standard ISO 10993‐1, ‘Biological evaluation of medical devices – Part 1: Evaluation and testing within a risk management process’ – Guidance for Industry and Food and Drug Administration Staff. 2020.
  • 46. Nasongkla N., Chen B., Macaraeg N., Fox M. E., Frã©Chet J. M. J., Szoka F. C., J. Am. Chem. Soc. 2009, 131, 3842. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 47. Loukotová L., Švec P., Groborz O., Heizer T., Beneš H., Raabová H., Bělinová T., Herynek V.­T., Hrubý M., Macromolecules 2021, 54, 8182. [Google Scholar]
  • 48. Luxenhofer R., Sahay G., Schulz A., Alakhova D., Bronich T. K., Jordan R., Kabanov A. V., J. Controlled Release 2011, 153, 73. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 49. Bak J. M., Lee H., J. Polym. Sci., Part A: Polym. Chem. 2013, 51, 1976. [Google Scholar]
  • 50. Halperin A., Kröger M., Winnik F. M., Angew. Chem., Int. Ed. 2015, 54, 15342. [DOI] [PubMed] [Google Scholar]
  • 51. Wyffels L., Verbrugghen T., Monnery B. D., Glassner M., Stroobants S., Hoogenboom R., Staelens S., J. Controlled Release 2016, 235, 63. [DOI] [PubMed] [Google Scholar]
  • 52. Liu J., Yu M., Zhou C., Zheng J., Mater. Today 2013, 16, 477. [Google Scholar]
  • 53. Fox M. E., Szoka F. C., Fréchet J. M. J., Acc. Chem. Res. 2009, 42, 1141. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 54. Naha P. C., Bhattacharya K., Tenuta T., Dawson K. A., Lynch I., Gracia A., Lyng F. M., Byrne H. J., Toxicol. Lett. 2010, 198, 134. [DOI] [PubMed] [Google Scholar]
  • 55. Akimoto J., Nakayama M., Sakai K., Okano T., Biomacromolecules 2009, 10, 1331. [DOI] [PubMed] [Google Scholar]
  • 56. Nakayama M., Chung J. E., Miyazaki T., Yokoyama M., Sakai K., Okano T., React. Funct. Polym. 2007, 67, 1398. [Google Scholar]
  • 57. Swanson J. A., Yoshida S. M., Encyclopedia of Cell Biology, (Eds: Bradshaw R. A., Stahl P. D.), Academic Press, Waltham, MA: 2016, pp. 758–765. [Google Scholar]
  • 58. Keller S., Berghoff K., Kress H., Sci. Rep. 2017, 7, 17068. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 59. Sakhtianchi R., Minchin R. F., Lee K.‐B., Alkilany A. M., Serpooshan V., Mahmoudi M., Adv. Colloid Interface Sci. 2013, 201–202, 18. [DOI] [PubMed] [Google Scholar]
  • 60. Sharma A., Vaghasiya K., Ray E., Verma R. K., J. Drug Targeting 2018, 26, 208. [DOI] [PubMed] [Google Scholar]
  • 61. Torchilin V. P. M., Nat. Rev. Drug Discovery 2014, 13, 813. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 62. T CP of pDFEA (particularly F2) is close to body temperature. Although the T CP of pDFEA (particularly F2) at high polymer concentrations is lower than body temperature, its T CP at low concentrations is higher than body temperature (Table S1 and Figure S2, Supporting Information). As a result, F2 initially aggregates after administration, but as this polymer dilutes and its T CP increases, F2 re‐dissolves and diffuses into the muscles, forming large depots (further discussed in ref. 83). Nevertheless, intracellular biodistributions of pDFEA resemble those of pNIPAM and pDEA, suggesting that pDFEA is localized in cells in its aggregated state.
  • 63. Seymour L. W., Duncan R., Strohalm J., Kopeček J., J. Biomed. Mater. 1987, 21, 1341. [DOI] [PubMed] [Google Scholar]
  • 64. Haute D. V., Berlin J. M., Ther. Delivery 2017, 8, 763. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 65. Zhang Y.‐N., Poon W., Tavares A. J., McGilvray I. D., Chan W. C. W., J. Controlled Release 2016, 240, 332. [DOI] [PubMed] [Google Scholar]
  • 66. Longmire M., Choyke P. L., Kobayashi H., Nanomedicine 2008, 3, 703. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 67. Schreiner G. F., JASN 1992, 2, S74. [DOI] [PubMed] [Google Scholar]
  • 68. Mauer S. M., Fish A. J., Blau E. B., Michael A. F., J. Clin. Invest. 1972, 51, 1092. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 69. Schlöndorff D., Kidney Int. 1996, 49, 1583. [DOI] [PubMed] [Google Scholar]
  • 70. Schlöndorff D., Banas B., JASN 2009, 20, 1179. [DOI] [PubMed] [Google Scholar]
  • 71.Interestingly, apart from kidney and liver, we did not detect any major signal in any other organ. Kidney and liver are among the most blood‐perfused organs,[ 86 ] each accounting for ca. 40% or 20% blood flow in BALB/c mice, respectively. Furthermore, these organs also contain cells with pronounced phagocytic activity. Other organs usually lack these phagocytic cells (e.g., intestines or brain) or are too shielded (e.g., brain) or diffuse to produce a noticeable signal (e.g., lungs).
  • 72.Small spheres of localized signal (e.g., in I2 at 5 h) can be ascribed to droplets of urine on the fur of the mouse.
  • 73. Van Durme K., Van Assche G., Van Mele B., Macromolecules 2004, 37, 9596. [Google Scholar]
  • 74. Zhao J., Hoogenboom R., Van Assche G., Van Mele B., Macromolecules 2010, 43, 6853. [Google Scholar]
  • 75. Aleksandrova R., Philipp M., Müller U., Riobóo R. J., Ostermeyer M., Sanctuary R., Müller‐Buschbaum P., Krüger J. K., Langmuir 2014, 30, 11792. [DOI] [PubMed] [Google Scholar]
  • 76.Shortly after administration, the urine and stool of our mice were strongly fluorescent, further confirming that the polymers are excreted via kidneys and liver.
  • 77. Sadauskas E., Wallin H., Stoltenberg M., Vogel U., Doering P., Larsen A., Danscher G., Part. Fibre Toxicol. 2007, 4, 10. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 78. Crofton R., Diesselhoff‐Den Dulk M., Furth R., J. Exp. Med. 1978, 148, 1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 79. Pabst R., Sterzel R. B., Kidney Int. 1983, 24, 626. [DOI] [PubMed] [Google Scholar]
  • 80. Yamaoka T., Tabata Y., Ikada Y., J. Pharm. Sci. 1995, 84, 349. [DOI] [PubMed] [Google Scholar]
  • 81. Yamaoka T., Tabata Y., Ikada Y., Drug Delivery 1993, 1, 75. [Google Scholar]
  • 82. Glassner M., Palmieri L., Monnery B. D., Verbrugghen T., Deleye S., Stroobants S., Staelens S., Wyffels L., Hoogenboom R., Biomacromolecules 2017, 18, 96. [DOI] [PubMed] [Google Scholar]
  • 83.The T CP should be measured at a specific polymer concentration (e.g., 1.25 mg mL−1), because T CP increases with decreasing polymer concentration (Figure S2, Supporting Information).[ 1 , 43 ] Therefore, when concentrated polymer solution is first administered, the polymer may initially aggregate, however, as polymer concentration decreased (due to its cellular uptake and its dissolution into bloodstream), its T CP at some point exceeds the body temperature and polymer aggregates re‐dissolve. This re‐dissolved polymer can subsequently freely diffuse through the muscle increasing volume of IM depot. If this re‐dissolution occurs at relatively high polymer concentrations (as seen in F2, Figure S2, Supporting Information) the polymers form diffuse IM depots (Figure 2). On the contrary, if the polymer re‐dissolution occurs only at low polymer concentration, the density of IM depot will be affected only negligibly. Thus, while the T CP of polymer solutions at high polymer concentration determines its initial aggregation, the T CP at low polymer concentrations (e.g., 1.25 mg mL−1) determines the depot diffuseness. Moreover, T CP in should be measured in biologically relevant fluids, such as serum (see ref. 87).
  • 84. Corrie P. G., Medicine 2008, 36, 24. [Google Scholar]
  • 85. Carrick S., Parker S., Thornton C. E., Ghersi D., Simes J., Wilcken N., Cochrane Database Syst. Rev. 2009, 2009, CD003372. [DOI] [PubMed] [Google Scholar]
  • 86. Gjedde S. B., Gjeode A., Comp. Biochem. Physiol., Part A: Mol. Integr. Physiol. 1980, 67, 671. [Google Scholar]
  • 87.We have previously demonstrated that polymer's T CP in serum can be significantly lower/higher than that seen in water.[ 43 ] As a result, when designing polymers for biomedical applications, the polymer's T CP should be assessed in as relevant media as possible (e.g., serum).
  • 88. Groborz O., Pharmacokinetics of Intramuscularly Administered Thermoresponsive Polyacrylamides. (Department of Organic Chemistry, Faculty of Science, Charles University, Prague, Czech Republic: 2021. [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supporting Information

Supplemental Video 1

Supplemental Video 2

Supplemental Video 3

Supplemental Video 4

Supplemental Video 5

Supplemental Video 6

Supplemental Video 7

Supplemental Video 8

Supplemental Video 9

Supplemental Video 10

Supplemental Video 11

Supplemental Video 12

Supplemental Video 13

Supplemental Video 14

Supplemental Video 15

Supplemental Video 16

Supplemental Video 17

Supplemental Video 18

Supplemental Video 19

ADHM-11-2201344-s002.rar (24.2MB, rar)

Supporting Information

Supporting Information

Supporting Information

Supporting Information

Supporting Information

ADHM-11-2201344-s004.rar (10.7MB, rar)

Supporting Information

Supporting Information

Supporting Information

Supporting Information

Supporting Information

Data Availability Statement

The data that support the findings of this study are available from the corresponding author upon reasonable request.


Articles from Advanced Healthcare Materials are provided here courtesy of Wiley

RESOURCES