Skip to main content
Materials logoLink to Materials
. 2024 Sep 26;17(19):4735. doi: 10.3390/ma17194735

Mechanical Properties and Chloride Penetration Resistance of Concrete Combined with Ground Granulate Blast Furnace Slag and Macro Synthetic Fiber

Shengzhao Cheng 1, Lisha Shen 2, Weige Chen 3,*, Haitang Zhu 4, Peibo You 5, Lu Chen 1
Editor: Yuri Ribakov
PMCID: PMC11477639  PMID: 39410306

Abstract

Concrete with good mechanical properties and durability has always been a necessity in engineering. The addition of fibers and supplementary cementitious materials to concrete can enhance its mechanical and durability performance through a series of chemical and physical interactions. This study aims to investigate the effects of key parameters on the compressive strength, splitting tensile strength, and chloride penetration resistance of concrete combined with ground granulate blast furnace slag (GGBS) and macro polypropylene synthetic fiber (MSF). Based on the Taguchi method, a total of eighteen mixtures were evaluated, considering the effects of GGBS content, MSF content, water-to-binder (w/b) ratio, and chloride solution concentration on concrete properties. The results showed that the w/b ratio has a significant impact on the properties of concrete, which are enhanced by a decrease in w/b ratio. The GGBS content had little effect on the 28-day strength of concrete, which even decreased with a large GGBS content, but GGBS had a positive effect on the long-term strength of concrete. Moreover, the chloride penetration resistance of concrete was enhanced by an increase in the GGBS content. The MSF content had no obvious effects on the compressive strength and chloride penetration resistance of concrete, but it could enhance the splitting tensile strength to some extent, and this enhancement was more obvious over time. The chloride diffusion coefficient of concrete changed with the concentration of chloride solution, and the two increased simultaneously.

Keywords: building materials, fiber-reinforced concrete, macro synthetic fiber, ground granulated blast furnace slag, mechanical properties, chloride diffusion coefficient

1. Introduction

Concrete is currently the most widely used artificial building material in the world. Due to its availability and low-cost advantages, it is extensively applied in various construction projects. Compared to other building materials such as steel, glass, wood, and brick, concrete not only has a lower price per kilogram but also has lower carbon emissions and energy consumption. Moreover, the use of concrete is enormous, estimated to exceed 10 billion cubic meters annually, playing an important role in economic development [1].

During its actual service, the durability of concrete structures is an unavoidable consideration, as they must face a variety of harsh environments. The intrusion of chloride ions is one of the main factors leading to the deterioration of concrete structures. Chloride ions are widely present in natural environments, particularly in marine environments, saline soils, and environments with de-icing salts [2,3]. Chloride ions penetrating the concrete reach the surface of the rebar, which destroys its passivation layer, causing rust expansion and leading to cracking and spalling of the concrete [4,5]. There are various strategies to enhance the resistance of concrete to chloride ion invasion, such as adding corrosion inhibitors to the concrete, coating surface, etc. However, the effectiveness of these methods is greatly reduced when the concrete cracks [6,7]. To ensure the long-term safe use of concrete structures, good mechanical properties and durability are required, especially the ability to protect the rebar from corrosion.

The use of fiber to reinforce concrete has attracted the attention of many scientists and building manufacturing institutions due to the benefits it provides. There are various types of reinforced fibers used in concrete, including steel fibers, glass fibers, natural fibers, and synthetic fibers. Steel fiber can greatly improve the tensile strength and bending strength of concrete, due to its extremely high strength and elastic modulus, and excellent bonding characteristics with concrete matrix [8,9]; however, the ability of steel fiber to maintain deactivation is questionable in the long-term harsh high-salt and high-humidity environment. Once steel fiber is seriously corroded, it will lead to the rapid degradation of the concrete structure’s performance [10]. Glass fiber has a good strengthening effect [11], but its alkali resistance is poor [12]. Natural fibers, such as sisal [13], palm [14], and sugarcane bagasse fibers [15], are cheap and easy to obtain, but their durability is poor [16]. Compared with the fibers of the above three materials, synthetic fiber has many advantages. Synthetic fibers are generally made of polymers; depending on the characteristics of the material, synthetic fibers can be elastic, flexible, or rigid [17]. Synthetic fibers made from materials such as polyethylene, polyvinyl alcohol, and polypropylene have been successfully used in the production of concrete [18]. Synthetic fiber can be obtained at low prices, resulting in labor and cost savings. Moreover, synthetic fiber has good durability and can exist stably in a concrete matrix. In addition, compared with steel fibers, synthetic fiber has multiple sustainable advantages, the most prominent of which is that it can reduce the carbon footprint, making it environmentally friendly. Some scholars have studied the influence of synthetic fiber on fresh concrete and hardened concrete, and the results show that the main advantages of synthetic fiber are the improvements in ductility in the post-crack region [19] and flexural toughness of concrete [20]. Moreover, the addition of synthetic fibers can change the failure mode of concrete, alter the essential characteristics of the brittle failure mode of concrete, and endow concrete with a certain degree of ductility. After the concrete cracks, the fibers between the cracks play a bridging role and transmit stress to the matrix on both sides of the cracks, thereby limiting the development of the cracks [21,22,23]. In addition, synthetic fiber can also effectively control plastic shrinkage cracking by improving the integrity of the fresh concrete [24]. These capabilities of synthetic fiber make it able to prevent water and pollutants from entering into deeper parts of a cracked concrete matrix, reducing the risk of reinforcement corrosion and deterioration of concrete structures. However, for uncracked concrete, the large number of fibers added into it will invariably introduce more interfaces between the fibers and cement matrix, thus affecting the overall permeability of the concrete; whether this will affect the ability of the concrete to be reinforced is worth further studying.

One of the characteristics of concrete with good durability is a large cement content, especially for high-strength and high-performance concrete. However, a high cement content also means greater consumption of natural resources, significant carbon dioxide emissions, and environmental pollution. Using supplementary cementitious materials (SCMs) is one of the effective ways to improve the environmentally friendly production of concrete [25]. Scientific and reasonable use of SCMs to replace ordinary Portland cement (OPC) can not only reduce the amount of cement in concrete and reduce the emission of greenhouse gases but also improve the characteristics of the concrete, such as reducing the hydration heat, enhancing its workability, and improving its durability. Ground granulated blast furnace slag (GGBS) is one of the commonly used SCMs and is a recycled industrial by-product in iron and steel manufacturing. Molten slag diverted from the iron blast furnace is rapidly chilled, producing glassy granules that yield desired reactive cementitious characteristics when ground into cement fitness. Using GGBS to replace part of OPC can reduce the heat required for hydration and also enable concrete to achieve faster strength development [26]. GGBS has been widely used in various projects to reduce the permeability and increase the durability of concrete. For example, 40% (mass percentage of cementitious materials) GGBS was used in the anchorage part of Japan’s Akashi Kaikyo Bridge [27]; 60% GGBS was adopted in the concrete caisson of Sydney Harbour Tunnel [28]; and 50% GGBS was utilized in the columns, decks, and barrier walls of Pinellas Bayway Bridge in Florida [26]. The addition of GGBS can improve the resistance of concrete to corrosive substances, but the difference in the activity between GGBS cement and OPC will inevitably affect the performance of concrete mechanical properties. Therefore, the influence of the proportional relationship between GGBS and OPC in concrete on the mechanical properties and durability of concrete deserves further study.

With the increasing application of concrete structures, high-quality concrete with good durability has become an urgent need in engineering practice. In this study, the Taguchi method was used to design combinations of the different influencing factors of concrete, and the compressive strength, splitting tensile strength, and chloride penetration resistance of each group were tested. The effects of water-to-binder ratio (w/b), GGBS content, and fiber content on the basic mechanical properties of concrete were studied. At the same time, the concentration of external immersed chloride solution was also considered in the study of the chloride penetration resistance of concrete. A range analysis and a variance analysis were used to study the influence and significance of each factor on the response. Based on the test results, mathematical models between the test variables and the responses were established by using a multiple regression analysis. Then, the signal-to-noise ratio (SNR) was introduced to analyze the influence of each factor on the concrete properties. In addition, scanning electron microscope (SEM) images and the failure mode morphology of concrete were also used to further illustrate the effects of the test variables on the responses. It is expected that the results of this study can provide a reference for the design of concrete combined with GGBS and fiber, so as to obtain concrete that achieves the basic mechanical properties and levels of durability.

2. Materials and Methods

2.1. Experimental Materials

The coarse aggregate used in this study is crushed limestone, and the fine aggregate is natural river sand with maximum particle sizes of 20 mm and 5 mm, respectively. The fineness modulus of river sand is 2.58, which can be classified as medium sand. Figure 1 shows the particle size distribution of coarse and fine aggregates. It can be seen that the grading of the aggregates is good, and the particle size curve complies with the provisions of ASTM C33 [29].

Figure 1.

Figure 1

Sieve curves of fine and coarse aggregates.

The OPC and GGBS used in this study were obtained from local sources. The grade of the OPC is 42.5, which can be approximately classified as Type I based on the ASTM C150 [30] standard, and the grade of the GGBS is S95, which can be classified as Grade 100 based on the ASTM C989 [31] standard. Table 1 and Table 2 are the physical and chemical properties of the OPC and GGBS, respectively.

Table 1.

Physical properties of the OPC and GGBS.

Physical Properties OPC GGBS
Specific surface area (m2/kg) 355 432
Bulk density (g/m3) 3.10 2.89
Initial setting time (min) 225 -
Final setting time (min) 277 -
3-day compressive strength (MPa) 32.4 -
3-day tensile strength (MPa) 6.2 -

Table 2.

Chemical composition of the OPC and GGBS.

Chemical Composition OPC (%) GGBS (%)
SiO2 20.60 32.91
Al2O2 4.81 15.36
Fe2O3 3.83 0.74
CaO 63.78 37.11
MgO 1.58 8.52
SO3 2.30 0.18
Cl 0.03 0.018
Heat loss 2.81 0.12

The fiber used in this study is macro synthetic fiber (MSF) made of polypropylene; its properties are shown in Table 3. To ensure that the fresh concrete has good workability, a highly efficient polycarboxylate superplasticizer with a solid content of 40% was used.

Table 3.

Properties of the MSF.

Length (mm) Diameter (μm) Density (g/cm3) Tensile Strength (N/mm2) Elasticity Modulus (GPa) Picture of the Fibers
30 800 0.91 450 3.5 graphic file with name materials-17-04735-i001.jpg

2.2. Experiment Design

In this study, the w/b, GGBS content, and fiber content were used as influencing factors for the mechanical properties. At the same time, regarding the aspect of resistance to chloride penetration, the concentration of chloride solution was also considered as an influencing factor. Table 4 lists the factors and levels of experiment.

Table 4.

Factors and levels of experiment.

Factors Levels
1 2 3 4 5 6
A. w/b 0.55 0.44 0.36
B. GGBS content (%mass of
cementitious material)
0 10 20 30 40 50
C. Fiber content (kg/m3) 3 6 9
D. Sodium chloride solution
concentration (%)
3.5 5.0 7.0

According to the factors and levels selected in this experiment, a mixed-level orthogonal table was used to design the experiment. Table 5 shows the arrangement of the orthogonal design, where A, B, C, and D represent the w/b, GGBS content, fiber content, and chloride solution concentration, respectively. Table 6 shows the corresponding concrete mix proportions.

Table 5.

The mixed-level orthogonal array for the Taguchi design.

Exp. No. Experimental Array L18
A B C D
1 1 1 1 1
2 2 1 2 2
3 3 1 3 3
4 1 2 1 2
5 2 2 2 3
6 3 2 3 1
7 1 3 2 3
8 2 3 3 1
9 3 3 1 2
10 1 4 3 2
11 2 4 1 3
12 3 4 2 1
13 1 5 2 1
14 2 5 3 2
15 3 5 1 3
16 1 6 3 3
17 2 6 1 1
18 3 6 2 2

Note: Factor D, the concentration of sodium chloride solution for wetting–drying cycles, was only considered in the design of the chloride penetration test, and it was used as an error column in the design of the basic mechanical property test. Exp. No. is the abbreviation for experiment number.

Table 6.

Mix proportions (kg/m3) for each group.

Exp. No. OPC GGBS Water Fine Aggregate Coarse Aggregate MSF Superplasticizer
1 340 0 170 756.0 1134.0 3 1.70
2 400 0 160 680.8 1159.2 6 2.00
3 500 0 150 612.5 1137.5 9 2.50
4 306 34 170 756.0 1134.0 3 1.53
5 360 40 160 680.8 1159.2 6 1.80
6 450 50 150 612.5 1137.5 9 2.25
7 272 68 170 756.0 1134.0 6 1.36
8 320 80 160 680.8 1159.2 9 1.60
9 400 100 150 612.5 1137.5 3 2.00
10 238 102 170 756.0 1134.0 9 1.19
11 280 120 160 680.8 1159.2 3 1.40
12 350 150 150 612.5 1137.5 6 1.75
13 204 136 170 756.0 1134.0 6 1.02
14 240 160 160 680.8 1159.2 9 1.20
15 300 200 150 612.5 1137.5 3 1.50
16 170 170 170 756.0 1134.0 9 0.85
17 200 200 160 680.8 1159.2 3 1.00
18 250 250 150 612.5 1137.5 6 1.25

2.3. Specimen Preparation and Testing

Specimens were prepared for the compressive strength, splitting tensile strength, and chloride penetration tests. First, the aggregate and fiber were added in a horizontal forced blender. After the blender was started, the cementitious materials and the water mixed with superplasticizer were added. Immediately after mixing, the mixtures were cast into a cubic specimen mold and compacted using a vibrating table. The specimens were then covered with a plastic film in the casting room for 24 h. Finally, the samples were demolded and cured in the curing room at 20 ± 2 °C and RH ≥ 95% until the test was performed.

2.3.1. Mechanical Test

Compressive strength and splitting tensile strength are basic mechanical properties of concrete. As shown in Figure 2, tests of these properties were conducted using a compression testing machine, the test process referenced the Chinese standard test methods for fiber-reinforced concrete (CECS 13-2009) [32]. The specimen size was 100 mm × 100 mm × 100 mm, three in each group, and the loading rate was 0.5 MPa/s for compressive strength and 0.05 MPa/s for splitting tensile strength. The strength was calculated using Equations (1) and (2):

RCS=PA1 (1)
RTS=2PπA2 (2)

where RCS is compressive strength (MPa); P is the maximum load at failure (N); and A1 is the compression and splitting tensile areas, both of which are 100 mm2. In this study, the substitution of GGBS for Portland cement reached 50% in some groups, and the large amount of SCMs slowed down the growth in the concrete strength. Therefore, in the strength test, not only the strength of the specimens at 28 days of standard age but also the long-term stable strength of the specimens after one year, that is 365 days, were tested.

Figure 2.

Figure 2

(a) The compressive strength test and (b) splitting tensile strength test of concrete.

2.3.2. Chloride Penetration Test

Wetting–Drying Cycles

The chloride penetration test referenced AASHOT T259 [33] and NT Build 443-94 [34]. Several pretreatments were carried out on the specimens before the wetting–drying cycles. In order to ensure the chloride penetration in only the one-dimensional direction, besides the one side selected as the exposed surface, the other five sides were coated with epoxy resin. Then, all specimens were put into a chest for wetting–drying cycles. A salinometer was used to ensure that the sodium chloride solution concentration error was within 0.2%. The experiment lasted for 24 cycles (2 days wet and 2 days dry for one cycle). This test was completed indoors, and the daily average temperature and relative humidity during the test were 23.6 °C and 67.8%, respectively.

Determination of Chloride Content

After 24 wetting–drying cycles, all specimens were taken out of the salt solution with different concentrations. After these specimens were dried in the natural environment, they were clamped on a concrete mill for grinding. Figure 3 shows a schematic diagram of the grinding process of the concrete specimen. From the chloride attack surface, the concrete was milled layer by layer with a constant thickness of 1 mm, and the concrete powder samples were collected into plastic sealing bags. Through this procedure, more data points can be provided in the process of establishing the chloride profile to make the results more accurate. All powder samples were then dried in an electric blast dryer, and coarse particles were removed using a No.100 sieve (# 0.15 mm). An automatic potentiometric titrator was used to determine the acid-soluble chloride in concrete; the titration solution was 0.01 mol/L silver nitrate solution, and the titrator automatically recorded the consumed volume of this solution. The chloride percent by mass of concrete was calculated by using

P=0.3545V1000m×100% (3)

where P is the mass percentage of chloride in the sample (%), V is the volume of consumed silver nitrate solution (mL), and m is the mass of the sample (g).

Figure 3.

Figure 3

Schematic diagram of the grinding process of the concrete specimen.

Chloride Diffusion Coefficient

The main mechanism of chloride transport in saturated concrete is diffusion, which is driven by the ion concentration gradient inside and outside the concrete. Fick’s law, as shown in Equation (4), is often used to describe the diffusion of chloride in concrete. Furthermore, when the latter is considered to be one-dimensional in a semi-infinite medium, an error equation solution of Fick’s second law is often used to describe the experimental data of the chloride profile in concrete, as shown in Equation (5):

Ct=D2Cx2 (4)
Cx,t=C0+(CsC0)1erfx2Dapp·t (5)

where x is the depth from the chloride attack surface (m), t is the exposure time (s), Cx,t is the chloride content (% by mass of concrete) at depth x and time t, C0 is the initial chloride content (% by mass of concrete), Cs is the chloride content at the surface (% by mass of concrete), Dapp is the apparent chloride diffusion coefficient (m2/s), and erf is the statistical error function.

It is worth mentioning that Fick’s second law can only be used in the diffusion zone of chloride in concrete. However, for concrete subjected to wetting–drying cycles, the chloride transport in concrete involves both diffusion and convection, in this case, the chloride profile does not always follow Fick’s law, and the region that involves both mechanisms is often called the convection zone [35]; it is usually the area from the exposed surface of the concrete to the point of peak chloride concentration. Its depth is a key parameter that can affect the prediction of the chloride profile in concrete cover, especially when using Fick’s second law to calculate the chloride content. Due to the presence of the convection zone, using the traditional Fick’s second law (i.e., Equation (5)) to calculate the diffusion coefficient of chloride can lead to distorted results. To settle this defect [36], the usual procedure is to move the axis (x=0) to the end of the convection zone where the chloride content reached its maximum, replacing the surface chloride content (Cs) with the maximum chloride content (Cm) and using (xxc) to replace x, where xc is the depth of the convection zone. Therefore, the chloride profile in concrete containing a convection zone can be described as follows:

Cx,t=C0+(CmC0)1erfxx02Dappt (6)

3. Results and Discussion

3.1. Experimental Results for 28-Day and 365-Day Compressive Strength

Table 7 shows the test results for 28-day compressive strength and 365-day compressive strength. Obviously, the 365-day compressive strength of all groups was higher than their 28-day compressive strengths. The mean value of the growth coefficient is 1.15, the standard deviation is 0.108, and the coefficient of variation is 9.4%. The results showed that after 365 days of curing, the compressive strength of concrete increased by an average of 15% compared to only 28 days of curing.

Table 7.

Experimental results for compressive strength.

Exp. No. w/b GGBS Content (%) Fiber Content (kg/m³) Compressive Strength (MPa)
28-Day Value 365-Day Value Growth Coefficient
1 0.55 0 3 34.30 38.96 1.14
2 0.44 0 6 44.88 48.91 1.09
3 0.36 0 9 48.79 50.85 1.04
4 0.55 10 3 41.72 44.06 1.06
5 0.44 10 6 46.94 47.43 1.01
6 0.36 10 9 50.82 51.50 1.01
7 0.55 20 6 41.36 44.87 1.08
8 0.44 20 9 47.53 53.88 1.13
9 0.36 20 3 48.91 50.54 1.03
10 0.55 30 9 37.32 43.90 1.18
11 0.44 30 3 43.54 51.81 1.19
12 0.36 30 6 46.83 56.41 1.20
13 0.55 40 6 34.13 37.90 1.11
14 0.44 40 9 41.30 54.71 1.32
15 0.36 40 3 51.33 67.72 1.32
16 0.55 50 9 34.83 40.13 1.15
17 0.44 50 3 45.64 59.87 1.31
18 0.36 50 6 48.47 65.05 1.34

A range analysis is an analytical approach using a Taguchi array. A range, which represents the influence of different factors on the test results, with a larger value indicates that the change in each level of factors in the test range will lead to greater changes in the response [37]. According to the range analysis, the order of influence of each factor on the test results can be deduced by comparing the range of each factor.

Table 8 presents the range analysis results for 28-day and 365-day compressive strength. It can be found that the range of specimens cured for 28 or 365 days had the following order: RA>RB>RC. Therefore, the influence of each factor on the compressive strength from large to small is w/b, GGBS content, and fiber content.

Table 8.

Range analysis of compressive strength.

Factor Level 28-Day Cubic Compressive Strength (MPa) 365-Day Cubic Compressive Strength (MPa)
A (w/b) B (GGBS Content) C (Fiber Content) A (w/b) B (GGBS Content) C (Fiber Content)
1 37.28 42.66 44.24 41.64 46.24 52.16
2 44.97 46.49 43.77 52.77 47.66 50.09
3 49.19 45.93 43.43 57.01 49.76 49.16
4 42.56 50.71
5 42.26 53.44
6 42.98 55.02
Range value 11.92 4.24 0.81 15.37 8.78 3.00
Rank order 1 2 3 1 2 3

A range analysis cannot distinguish the data fluctuation caused by test errors and a change in test conditions. In order to remedy the defects of the range analysis, a repeated analysis of variance (ANOVA) test without any empty columns was adopted. Table 9 and Table 10 show the ANOVA results for 28-day and 365-day compressive strength, respectively. As shown in Table 9, the w/b had an extremely significant effect, with the highest contribution rate of 79.38% to the variance, while the contribution rate of GGBS content was small (5.24%) and the influence of fiber was small, which was within the error. Similarly, for the 365-day long-term compressive strength, each factor had the same influence regular pattern. The contribution rates of w/b and GGBS content were 59.02% and 2.86%, respectively.

Table 9.

ANOVA for 28-day compressive strength.

Variance Source Sum of Squares Df Mean Square F Value Significance Contribution of Factor (%)
w/b 439.001 2 219.501 44.870 0.000 79.38
GGBS content 52.789 5 10.558 2.158 0.141 5.24
Fiber content Δ 2.014 2 1.007
Error 46.904 8 5.863
Error Δ 48.918 10 4.892
Total 540.709 17

Note: The effect of fiber content is within the error.

Table 10.

ANOVA for 365-day compressive strength.

Variance Source Sum of Squares Df Mean Square F Value Significance Contribution of Factor (%)
w/b 756.239 2 378.120 14.161 0.001 59.02
GGBS content 167.514 5 33.503 1.255 0.354 2.86
Fiber content Δ 28.285 2 14.143
Error 238.724 8 29.841
Error Δ 267.009 10 26.701
Total 1190.763 17

Note: The effect of fiber content is within the error.

Based on the experimental results, mathematical models for 28-day and 365-day compressive strength were developed using a multiple regression analysis. Considering the consistency of the order of magnitude of the regression coefficients, the independent variable, fiber content, was substituted by volume fraction (Vf); 3 kg/m3 fiber content corresponds to 0.33% Vf, 6 kg/m3 fiber content corresponds to 0.66% Vf, and 9 kg/m3 fiber content corresponds to 0.99% Vf.

The mathematical model for 28-day compressive strength is as follows:

y=73.2163.16x126x22+8.86x21.23x3 (7)
R2=0.8422

where y is the 28-day compressive strength, x1 is the w/b, x2 is the GGBS-to-cement ratio, and x3 is the fiber volume fraction (%).

And, the mathematical model for 365-day compressive strength is as follows:

y=85.9982.12x1+17.76x24.55x3 (8)
R2=0.7803

where y is the 365-day compressive strength, x1 is the w/b, x2 is the GGBS-to-cement ratio, and x3 is the fiber volume fraction (%).

In Figure 4, the experimental values and the predicted values, which were calculated using the proposed mathematical model, for the 28-day and 365-day compressive strength were compared. It was found that the data points are basically distributed in the range of ±25% from the mean line, indicating that the mathematical model can be used to predict the compressive strength value.

Figure 4.

Figure 4

Comparison of the compressive strength between model calculation and experimental data.

3.2. Experimental Results for 28-Day and 365-Day Splitting Tensile Strength

Table 11 shows the results of 28-day and 365-day splitting tensile strength. It was found that the 365-day splitting tensile strength in most groups is higher than the 28-day strength. The mean value of the strength growth coefficient is 1.12, the standard deviation is 0.178, and the coefficient of variation is 15.9%. The results also indicated that the splitting tensile strength shows an increasing trend over time. In addition, the variation in the splitting tensile strength growth coefficient was greater than that of the compressive strength growth coefficient, which shows that the dispersion degree of splitting tensile strength is higher than that of compressive strength.

Table 11.

Experimental results for splitting tensile strength.

Exp. No. w/b GGBS Content (%) Fiber Content (kg/m³) Splitting Tensile Strength Growth Coefficient
28-Day Value 365-Day Value
1 0.55 0 3 3.37 3.32 0.99
2 0.44 0 6 4.51 4.18 0.93
3 0.36 0 9 4.64 4.39 0.95
4 0.55 10 3 3.47 3.86 1.11
5 0.44 10 6 4.22 4.22 1.00
6 0.36 10 9 4.14 4.99 1.21
7 0.55 20 6 3.75 3.36 0.90
8 0.44 20 9 4.17 4.49 1.08
9 0.36 20 3 3.88 5.86 1.51
10 0.55 30 9 3.51 4.49 1.28
11 0.44 30 3 3.88 3.78 0.97
12 0.36 30 6 4.08 4.76 1.17
13 0.55 40 6 3.12 4.49 1.44
14 0.44 40 9 3.55 4.64 1.31
15 0.36 40 3 4.41 3.84 0.87
16 0.55 50 9 3.62 4.33 1.20
17 0.44 50 3 3.98 4.19 1.05
18 0.36 50 6 3.78 4.24 1.12

Table 12 is the range analysis results of 28-day and 365-day splitting tensile strength. It can be found that the range order is the same for the specimens cured for 28 days and 365 days: RA>RB>RC. Therefore, the influence of each factor on the splitting tensile strength from large to small is w/b, GGBS content, and fiber content. It is worth mentioning that the range of each factor at 365 days had different degrees of improvement compared with at 28 days, but the fiber content range showed the largest increase, from 0.106 to 0.413, with an increase of 289.6%. This also showed that the role of fibers in long-term aging was more obvious.

Table 12.

Range analysis of the splitting tensile strength.

Factor Level 28-Day Splitting Tensile Strength (MPa) 365-Day Splitting Tensile Strength (MPa)
A (w/b) B (GGBS Content) C (Fiber Content) A (w/b Ratio) B (GGBS Content) C (Fiber Content)
1 3.473 4.169 3.831 3.975 3.963 4.140
2 4.051 3.943 3.909 4.250 4.355 4.209
3 4.154 3.933 3.937 4.678 4.569 4.554
4 3.823 4.343
5 3.693 4.323
6 3.793 4.252
Range value 0.681 0.476 0.106 0.703 0.605 0.413
Rank order 1 2 3 1 2 3

Table 13 and Table 14 presented the ANOVA for 28-day and 365-day splitting tensile strength, respectively. The ANOVA results of splitting tensile strength for 28 days showed that, compared with GGBS content and fiber content, w/b had an extremely significant influence. Its contribution to the variance is 49.72%, whereas other factors could be within the error. For the 365-day long-term splitting tensile strength, the influence of w/b was significantly decreased, but the contribution rate of w/b was still the highest of all the factors, at 15.72%. Although the contribution rate of fiber content was only 0.08%, it could be distinguished from the error, which further showed that the effect of fiber content on the splitting tensile strength of concrete is more obvious in the long term.

Table 13.

ANOVA for 28-day splitting tensile strength.

Variance Source Sum of Squares Df Mean Square F Value Significance Contribution of Factor (%)
w/b 1.617 2 0.809 9.417 0.002 49.72
GGBS content Δ 0.405 5 0.081
Fiber content Δ 0.036 2 0.018
Error 0.847 8 0.106
Error Δ 1.288 15 0.086
Total 2.906 17

Note: The effects of GGBS content and fiber content are within the error.

Table 14.

ANOVA for 365-day splitting tensile strength.

Variance Source Sum of Squares Df Mean Square F Value Significance Contribution of Factor (%)
w/b 1.515 2 0.758 2.589 0.113 15.72
GGBS content Δ 0.582 5 0.116
Fiber content 0.591 2 0.295 1.010 0.391 0.08
Error 3.222 8 0.403
Error Δ 3.804 13 0.293
Total 5.910 17

Note: The effects of GGBS content are within the error.

Based on the experimental results, mathematical models for 28-day and 365-day splitting tensile strength were proposed. The regression equation for 28-day splitting tensile strength is as follows:

y=1.4720.87x12+15.4x1+2.05x221.81x2+0.16x3 (9)
R2=0.7951

where y is the 28-day splitting tensile strength; x1 is w/b; x2 is the GGBS-to-cement ratio; and x3 is the fiber volume fraction (%).

And, the regression equation for 365-day splitting tensile strength is as follows:

y=8.76+15.03x1217.37x15.80x22+3.22x2+1.27x321.05x3 (10)
R2=0.7678

where y is the 365-day splitting tensile strength, x1 is w/b, x2 is the GGBS-to-cement ratio, and x3 is the fiber volume fraction (%).

As for the analysis method for compressive strength, the experimental values and the predicted values, which were calculated using the proposed equation, for the 28-day and 365-day splitting tensile strengths were also compared and graphically presented in Figure 5. It can be seen from the comparison diagram that the proposed equation is suitable for predicting the splitting tensile strength.

Figure 5.

Figure 5

Comparison of the splitting tensile strength between model calculation and experimental data.

3.3. Experimental Results for Chloride Penetration Resistance

The typical chloride profile measured during the test for group 13 is presented in Figure 6 and Figure 7. The data points were fitted using Equations (5) and (6), respectively, and the chloride diffusion coefficients were also calculated. It can be found that due to the presence of convection zones, when Equation (5) was used, the calculated surface chloride ion concentration was much higher than the actual surface chloride concentration, while Equation (6) ignored the convection zone in the calculation and directly calculated the peak chloride concentration as the equivalent surface chloride concentration. A comparison of the two sets of results showed that the R-square value from Equation (6) is larger than that from Equation (5), indicating that Equation (6) has a better fitting degree for the chloride profile. The surface chloride concentration, Cs, obtained by Equation (5) was larger than the actual Cs (Cs,calculated=0.4185%>Cs,actual=0.3074%). This result indicates that in the process of chloride transport in the surface layer of concrete, the concentration gradient is the main driving force, which is inconsistent with the actual chloride profile. Because the Cs value from Equation (5) was higher, the predicted service life to reach the chloride threshold will be shorter than that when using the value from Equation (6). Therefore, this equation is better at describing the law of chloride penetration in concrete under wetting–drying cycles.

Figure 6.

Figure 6

The calculation results of Dapp using Equation (5).

Figure 7.

Figure 7

The calculation results of Dapp using Equation (6).

After 24 wetting–drying cycles, the apparent chloride diffusion coefficients (Dapp) of the specimens were calculated using Equation (6), and the results are represented in Table 15.

Table 15.

Experimental results for apparent chloride diffusion coefficient.

Exp. No. w/b GGBS Content (%) Fiber Content (kg/m3) Concentration of Sodium Chloride Solution (%) Mean Value of Dapp (×10−12 m2/s)
1 0.55 0 3 3.5 9.03
2 0.44 0 6 5 8.90
3 0.36 0 9 7 7.07
4 0.55 10 3 5 12.87
5 0.44 10 6 7 7.17
6 0.36 10 9 3.5 3.67
7 0.55 20 6 7 11.66
8 0.44 20 9 3.5 5.59
9 0.36 20 3 5 3.10
10 0.55 30 9 5 10.96
11 0.44 30 3 7 5.28
12 0.36 30 6 3.5 3.51
13 0.55 40 6 3.5 8.64
14 0.44 40 9 5 4.42
15 0.36 40 3 7 3.30
16 0.55 50 9 7 10.53
17 0.44 50 3 3.5 3.73
18 0.36 50 6 5 1.51

Table 16 shows the range analysis results of Dapp after 24 wetting–wetting cycles. It can be found that the range order is RA>RB>RD>RC. In other words, the factors in the chloride penetration resistance of concrete had the following order of importance: w/b, GGBS content, chloride solution concentration, and fiber content.

Table 16.

Range analysis of the chloride diffusion coefficient.

Factor Level Chloride Diffusion Coefficient after 24 DryingWetting Cycles (×1012 m2/s)
A (w/b) B (GGBS Content) C (Fiber Content) D (Concentration of Sodium Chloride Solution)
1 10.614 8.332 6.219 5.695
2 5.849 7.905 6.898 6.961
3 3.693 6.783 7.040 7.501
4 6.584
5 5.453
6 5.255
Range value 6.921 3.077 0.821 1.806
Rank order 1 2 4 3

Table 17 shows the ANOVA results of Dapp after 24 wetting–drying cycles. It showed that, compared with other factors, w/b has a remarkable impact, and the contribution rate of variance is 74.32%. This was followed by the GGBS content and chloride solution concentration, which had contribution rates of 7.45% and 3.48%, respectively. The influence of fiber content on chloride penetration resistance of concrete is not apparent, and it can be within the error.

Table 17.

ANOVA results for Dapp.

Variance Source Sum of Squares Df Mean Square F Value Significance Contribution of Factor (%)
w/b 150.521 2 75.261 43.830 0.000 74.32
GGBS content 23.328 5 4.666 2.717 0.101 7.45
Fiber content Δ 2.312 2 1.156
Solution concentration 10.314 2 5.157 3.003 0.106 3.48
Error 11.425 6 1.904
Error Δ 13.737 8 1.717
Total 197.900 17

Note: The effect of fiber content is within the error.

Based on the experimental results, mathematical models for Dapp were proposed, and the regression Equation is as follows:

y=11.64+36.85x16.55x2+1.25x3+0.5x4 (11)
R2=0.9205

where y is the Dapp of chloride ions after 24 drying–wetting cycles, x1 is the w/b, x2 is the GGBS-to-cement ratio, x3 is the fiber volume fraction (%), and x4 is the solution concentration of chloride (%).

Figure 8 shows the comparison of the experimental values and predicted values of Dapp, and there is good consistency between both sides.

Figure 8.

Figure 8

Comparison of the Dapp between model calculation and experimental data.

3.4. Signal-to-Noise Ratio (SNR)

In the Taguchi orthogonal array, rows and columns represent the number of factors and experiments, respectively, and the influence of factors on the response was determined by the symmetric change in factor level. SNR was utilized to further analyze the results. The value of SNR represents the variance around a specific value, in other words, the changes in the response of several tests to an indicator. The calculation of SNR can be divided into three categories:

Smaller the better SN=10log101ni=1nyi2 (12)
Lager the better SN=10log101ni=1n1yi2 (13)
Nominal the better SN=10log10σ2 (14)

where n is the number of test repetitions and yi is the experimental obtained value [38].

SNR reflects the influence of control factors on the response, and a higher SNR value means a better response value. In this paper, for the “the larger the better” condition, Equation (13) was selected to calculate the SNR values for the compressive strength and splitting tensile strength of concrete, while for the “the smaller the better” condition, Equation (12) was selected for the apparent chloride diffusion coefficient. Table 18 lists the SNR values of each index for each group.

Table 18.

SNR values of each group.

Exp. No. SNR Value
28-Day Compressive Strength 365-Day Compressive Strength 28-Day Splitting Tensile Strength 365-Day Splitting Tensile Strength Dapp
1 30.68 31.81 10.54 10.43 −19.12
2 33.02 33.79 13.07 12.43 −18.99
3 33.76 34.13 13.32 12.84 −16.98
4 32.40 32.88 10.81 11.73 −22.19
5 33.43 33.52 12.51 12.51 −17.11
6 34.11 34.24 12.34 13.96 −11.30
7 32.33 33.04 11.48 10.53 −21.34
8 33.54 34.63 12.40 13.04 −14.95
9 33.78 34.07 11.78 15.35 −9.82
10 31.44 32.85 10.91 13.04 −20.80
11 32.77 34.29 11.78 11.55 −14.46
12 33.39 35.03 12.21 13.55 −10.91
13 30.64 31.57 9.88 13.04 −18.73
14 32.30 34.76 11.00 13.33 −12.92
15 34.21 36.61 12.89 11.68 −10.37
16 30.84 32.07 11.17 12.73 −20.44
17 33.16 35.54 12.00 12.44 −11.43
18 33.68 36.26 11.55 12.55 −3.59

3.4.1. SNR Results of Compressive Strength

In Figure 9 and Figure 10, it can be observed that the compressive strength decreases with an increase in w/b, regardless of whether the specimen was cured for 28 days or 365 days, and the compressive strength reaches the maximum when w/b is 0.36. In general, a decrease in the w/b decreases the porosity of cementitious matrix, upgrades the microstructure of the interfacial transition zone around the aggregate, and increases the density and strength of concrete.

Figure 9.

Figure 9

The mean main effects plots of SNR for 28-day compressive strength.

Figure 10.

Figure 10

The mean main effects plots of SNR for 365-day compressive strength.

The effect of GGBS content on the compressive strength at 28 days and 365 days are quite different. For a short age of 28 days, when the GGBS content is low (10% and 20%), the compressive strength shows a slight increase, and with a further increase in GGBS content, the compressive strength shows a decreasing trend. However, even with the highest content (50%) considered in this study, the compressive strength of concrete is not significantly reduced. For the extended age of 365 days, it can be found that the compressive strength increases with the GGBS content. Compared with OPC, the GGBS used in this study had a larger specific surface area and smaller particle size. In the early stages, GGBS could have a certain physical filling effect, which would improve the compactness of the hardened cement slurry. The GGBS also provided large nucleation surfaces for hydration products and promoted their formation [39]. However, with a further increase in GGBS content, the OPC content obviously decreased, which led to a decrease in the hydration products. As the hydration process continued, the GGBS activity in the alkaline environment was further stimulated, and a secondary hydration reaction occurred, which consumed calcium hydroxide (CH) and formed a dense hydrated calcium silicate (CSH) gel [40]. Thus, the concrete had a higher strength.

The micro morphology of hardened pastes can be used to characterize the compactness of the paste structure, the morphological characteristics of the hydration products, and the participation degree of cementitious material particles in hydration. It is of great significance to analyze the hydration process and reveal the hydration mechanism. Figure 11 and Figure 12 show the SEM images of the 28-day and 365-day freshly fractured surfaces of the samples, respectively. In Figure 11, it can be seen that the hydration products of the samples (the specimens of group 17) were abundant at 28 days, with these hydration products distributed on the surfaces of the unhydrated particles. The paste structure was not dense enough, and the bonding between hydration products was not compact. Laminated CH and a large number of flocculent CSH gel can also be observed in the figure, and needle ettringite (AFt) can be found in large pores. The micromorphological appearance of the sample can be seen in the SEM image of the 365-day specimen (Figure 12); sufficient hydration products were produced with an increase in age, and the matrix became dense. Because the latent reactivity of the GGBS was excited, the degree of GGBS reaction was increased. It can be observed that the polygonal GGBS particles were surrounded by a dense gel and tightly adhered to the surrounding matrix, which filled the pores well, and the hardened paste was compact. Therefore, at the early age of 28 days, the lower GGBS content could improve the strength of the concrete, whereas at the greater age of 365 days, a larger GGBS content could also effectively improve the strength.

Figure 11.

Figure 11

SEM image of hardened concrete at 28 days.

Figure 12.

Figure 12

SEM image of hardened concrete at 365 days.

It also can be found in Figure 9 and Figure 10 that the 28-day and 365-day compressive strengths decreased slightly with the increases in fiber content, but the overall effect was not significant. This may be because the elastic modulus of MSF used is far smaller than that of the concrete matrix. In general, the elastic modulus of concrete with ordinary strength is 25~35 GPa, while the elastic modulus of MSF is only 3.5 GPa. In a sense, dispersing the fibers in the concrete was equivalent to introducing a large number of randomly distributed low modulus defects [41]. When the specimens were subjected to an external load, an internal stress concentration could easily occur, which decreased the compressive strength of concrete.

3.4.2. SNR Results of Splitting Tensile Strength

The splitting tensile strength is an indirect index reflecting the tensile performance and toughness of concrete. The SNRs of 28-day and 365-day splitting tensile strength are plotted in Figure 13 and Figure 14, which shows the variation in splitting tensile strength at each factor level. It can be observed from the figure that the variation law of splitting tensile strength with a change in w/b is the same as that of compressive strength, where both decrease with an increase in w/b. The 28-day splitting tensile strength decreases with the increase in the GGBS content. And, compared with the concrete without GGBS, the 365-day splitting tensile strength of concrete has different degrees of growth with a change in the GGBS content. The effects of w/b and GGBS content on the splitting tensile strength of concrete mechanisms are similar to those for the compressive strength. However, in contrast to the effect of fiber content on the compressive strength, the splitting tensile strength of concrete increases with an increase in fiber content, and the range of increase for 365 days is greater than that for 28 days. In other words, the strengthening effect of fiber on the splitting tensile strength of concrete is more obvious after a long curing period.

Figure 13.

Figure 13

The mean main effects plots of SNR for 28-day splitting tensile strength.

Figure 14.

Figure 14

The mean main effects plots of SNR for 365-day splitting tensile strength.

According to fiber spacing theory, the theoretical calculation of the MSF spacing used in this study is 10~20 mm [42], which matched the size of coarse aggregates. Thus, the fiber could be evenly dispersed in concrete. The SEM images of MSF presented in Figure 15 and Figure 16 show that the fiber has a fairly good bonding state in the concrete, and the crude surface of the fiber further strengthened the bond between the fiber and the concrete matrix.

Figure 15.

Figure 15

SEM image of MSF in concrete.

Figure 16.

Figure 16

SEM image of MSF surface after debonding from concrete matrix.

In addition, the effect of fiber on splitting tensile strength was also reflected in the surface morphology of the fiber in the concrete failure sections. Figure 17 shows the pull-out states of the fiber in the concrete sections after the splitting tensile strength test after curing for 28 days and 365 days. During the splitting tensile test, with an increase in external load, the microcracks in the weak interface of the matrix penetrated through, and the fiber bridged in the fracture surface began to bear the load and transferred it to the uncracked part. As the cracks continued to open, the bridging fibers were constantly pulled out or broke. The pull-out resistance of the fiber was mainly determined by the bonding between the fiber and the matrix and the mechanical interaction caused by the special shape of the fiber surface [43]. It can be seen from the 28-day concrete failure morphology that after the section was completely fractured, some fibers still showed a crimped pattern on the surface, which indicates that the bond between the fiber and the matrix was weak and the effect of the fiber on the splitting tensile strength was not obvious. From the fracture morphology of the 365-day concrete, it can be seen that most of the fiber was stretched and some fibers even ruptured. This phenomenon indicated that the interface between fiber and concrete matrix increased with the increase in age. Therefore, after a long period of curing, the fiber played a greater role in improving the tensile strength of the concrete.

Figure 17.

Figure 17

The morphology of the fiber in concrete during the 28 day and 365 day splitting tensile tests.

3.4.3. SNR Results of Apparent Chloride Diffusion Coefficient

Figure 18 shows the influences of several factors and levels on the Dapp after 24 wetting–drying cycles. It can be found that the chloride penetration resistance of concrete increases with a decrease in w/b; it also increased with an increase in the GGBS content and slightly decreased with the increase in the fiber content and external chloride solution concentration.

Figure 18.

Figure 18

The main effects plots of SNR for Dapp.

A decrease in w/b increased the density of concrete and enhanced its ability to resist chloride penetration. The addition of GGBS could also make the concrete more impenetrable, block the transport path of chlorides, and significantly change the hydration products. In addition to the CSH gel generated by the secondary hydration of GGBS, Friedel’s salt also formed in the concrete due to the higher alumina content of GGBS. On the whole, the concrete mixed with GGBS can absorb more chlorides, which enhanced its chloride penetration resistance [44]. The addition of fiber introduced more interfaces in concrete, which affected its overall anti-chloride penetration performance [45,46]. The interface increased with an increase in fiber content, and the chloride penetration resistance of concrete exhibited a slight weakening trend. Chloride transport in concrete is a complicated process [47], including capillary suction, migration in an electrical field, and wick action, and the main driving force of chloride transport depends on the concentration gradient between the internal and external parts of the concrete, with a faster transmission speed of chlorides at a high concentration gradient. Therefore, the chloride penetration resistance of concrete decreased with an increase in the external solution concentration. And, this also indicated that the chloride penetration resistance of concrete is related not only to the properties of the concrete itself but also to the external conditions encountered by the concrete.

Therefore, when considering the basic mechanical properties and chloride penetration resistance of concrete, w/b is the most important control factor in the design of the ordinary strength of concrete, and a lower w/b should be selected within the required strength range. Second, under the condition of meeting the strength requirements, a large amount of GGBS can be used to reduce the amount of OPC, which will improve the utilization rate of high-energy-consumption cement and achieve the best use of the materials. Then, the addition of MSF can improve the tensile strength of concrete. However, it has no obvious effect on its compressive strength and chloride penetration resistance; therefore, the appropriate dosage of MSF can be selected in consideration of the cost.

4. Conclusions

In this study, several parameters that were expected to influence the basic mechanical properties and chloride penetration resistance of concrete were considered. The Taguchi method was adopted in the group design, and the SNR was introduced to analyze the influence law of various parameters on the characteristics of concrete. The following are the main conclusions drawn from this study:

  1. w/b had a significant impact on the compressive strength, splitting tensile strength, and chloride penetration resistance of concrete, with these properties of concrete all improved or enhanced with a decrease in w/b.

  2. The addition of GGBS could improve the long-term strength and chloride penetration resistance of concrete. A lower GGBS content (10%~20%) could slightly enhance the 28-day compressive strength of concrete, but with a further increase in the GGBS content (30%~50%), the compressive strength of concrete decreased. However, the 365-day compressive strength of concrete increased with an increase in the GGBS content. Compared with the OPC concrete, adding GGBS could reduce the 28-day splitting tensile strength of concrete. However, similar to the compressive strength, the addition of GGBS played a positive role in the 365-day splitting tensile strength. And, GGBS could improve the ability of concrete to resist chloride penetration. Within the range of GGBS content considered in this study, the chloride penetration resistance of concrete increased with an increase in GGBS content.

  3. The addition of MSF has no obvious effect on the compressive strength and chloride penetration resistance of concrete. MSF could improve the splitting tensile strength of concrete, and the strengthening effect after 365 days was more obvious than that after 28 days.

  4. Dapp increased with an increase in the concentration of chloride solution used for wetting–drying cycles, which indicated that the ability of concrete to resist chloride penetration is related not only to the properties of the concrete itself but also to the external environment encountered by the concrete.

  5. Based on the considered parameters, the mathematical regression models of compressive strength, splitting tensile strength, and chloride permeability of concrete were established. There is good consistency between the calculated and measured values of the model, but the accuracy of the model needs to be further improved.

In conclusion, the addition of MSF and GGBS can enhance the performance of concrete, but it can also cause some negative effects. This study only conducted preliminary research on the basic mechanical properties and resistance to chloride penetration under drying–wetting cycles. Future research can be combined with specific application backgrounds to further study the more complex mechanical properties of concrete containing MSF and GGBS, including but not limited to bending, direct tension, impact, etc. In terms of durability, in addition to chloride ion penetration, resistance to sulfate corrosion, freeze–thaw cycles, and high temperature resistance are all worthy of further research.

Author Contributions

Conceptualization, S.C. and W.C.; Data curation, L.S. and L.C.; Funding acquisition, P.Y.; Investigation, W.C. and L.C.; Methodology, W.C.; Project administration, S.C.; Resources, S.C., H.Z., P.Y. and L.C.; Supervision, H.Z. and P.Y.; Visualization, L.S.; Writing—review and editing, H.Z. All authors have read and agreed to the published version of the manuscript.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The original contributions presented in the study are included in the article, further inquiries can be directed to the corresponding author.

Conflicts of Interest

Author Shengzhao Cheng was employed by the company China Construction Seventh Engineering Division Corp., Ltd. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest. Besides, the authors declare that this study received funding from the China Construction Seventh Engineering Division Corp., Ltd. The funder was not involved in the study design, collection, analysis, interpretation of data, the writing of this article or the decision to submit it for publication.

Funding Statement

This work was supported by the China Construction Seventh Engineering Division Corp., Ltd. (CSCEC7b-2021-Z-9); the Natural Science Foundation of Henan Province (232300420102); and the China National Natural Science Foundation Youth Fund Project (52108207).

Footnotes

Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

References

  • 1.Coffetti D., Crotti E., Gazzaniga G., Carrara M., Pastore T., Coppola L. Pathways towards sustainable concrete. Cem. Concr. Res. 2022;154:106718. doi: 10.1016/j.cemconres.2022.106718. [DOI] [Google Scholar]
  • 2.Li Y., Sheng J., Tan K.H., Gao Y. Effect of pore structure on shear resistance and chloride transport of macro-synthetic fiber reinforced concrete. Constr. Build. Mater. 2023;382:131366. doi: 10.1016/j.conbuildmat.2023.131366. [DOI] [Google Scholar]
  • 3.Li P., Li C., Jia C., Li D. A comparative study on chloride diffusion in concrete exposed to different marine environment conditions. J. Build. Eng. 2024;94:109845. doi: 10.1016/j.jobe.2024.109845. [DOI] [Google Scholar]
  • 4.Raczkiewicz W., Bacharz M., Bacharz K., Teodorczyk M. Reinforcement Corrosion Testing in Concrete and Fiber Reinforced Concrete Specimens Exposed to Aggressive External Factors. Materials. 2023;16:1174. doi: 10.3390/ma16031174. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Liu J., Jiang Z., Zhao Y., Zhou H., Wang X., Zhou H., Xing F., Li S., Zhu J., Liu W. Chloride Distribution and Steel Corrosion in a Concrete Bridge after Long-Term Exposure to Natural Marine Environment. Materials. 2020;13:3900. doi: 10.3390/ma13173900. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Guo X., Wang C., Fu H., Tian L., Song H. Rust Prevention Property of a New Organic Inhibitor under Different Conditions. Materials. 2024;17:2168. doi: 10.3390/ma17092168. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Zheng W., Chen W.G., Feng T., Li W.Q., Liu X.T., Dong L.L., Fu Y.Q. Enhancing chloride ion penetration resistance into concrete by using graphene oxide reinforced waterborne epoxy coating. Prog. Org. Coat. 2019;138:105389. doi: 10.1016/j.porgcoat.2019.105389. [DOI] [Google Scholar]
  • 8.Guo S., Ding Y., Zhang X., Xu P., Bao J., Zou C. Tensile properties of steel fiber reinforced recycled concrete under bending and uniaxial tensile tests. J. Build. Eng. 2024;96:110467. doi: 10.1016/j.jobe.2024.110467. [DOI] [Google Scholar]
  • 9.Gong Y., Hua Q., Wu Z., Yu Y., Kang A., Chen X., Dong H. Effect of Basalt/Steel Individual and Hybrid Fiber on Mechanical Properties and Microstructure of UHPC. Materials. 2024;17:3299. doi: 10.3390/ma17133299. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Söylev T., Özturan T. Durability, physical and mechanical properties of fiber-reinforced concretes at low-volume fraction. Constr. Build. Mater. 2014;73:67–75. doi: 10.1016/j.conbuildmat.2014.09.058. [DOI] [Google Scholar]
  • 11.Tassew S., Lubell A. Mechanical properties of glass fiber reinforced ceramic concrete. Constr. Build. Mater. 2014;51:215–224. doi: 10.1016/j.conbuildmat.2013.10.046. [DOI] [Google Scholar]
  • 12.Madhkhan M., Katirai R. Effect of pozzolanic materials on mechanical properties and aging of glass fiber reinforced concrete. Constr. Build. Mater. 2019;225:146–158. doi: 10.1016/j.conbuildmat.2019.07.128. [DOI] [Google Scholar]
  • 13.Mo K.H., Alengaram U.J., Jumaat M.Z., Yap S.P., Lee S.C. Green concrete partially comprised of farming waste residues: A review. J. Clean. Prod. 2016;117:122–138. doi: 10.1016/j.jclepro.2016.01.022. [DOI] [Google Scholar]
  • 14.Aziz F.N.A.A., Bida S.M., Nasir N.A.M., Jaafar M.S. Mechanical properties of lightweight mortar modified with oil palm fruit fibre and tire crumb. Constr. Build. Mater. 2014;73:544–550. doi: 10.1016/j.conbuildmat.2014.09.100. [DOI] [Google Scholar]
  • 15.Alavéz-Ramírez R., Montes-García P., Martínez-Reyes J., Altamirano-Juárez D.C., Gochi-Ponce Y. The use of sugarcane bagasse ash and lime to improve the durability and mechanical properties of compacted soil blocks. Constr. Build. Mater. 2012;34:296–305. doi: 10.1016/j.conbuildmat.2012.02.072. [DOI] [Google Scholar]
  • 16.Torgal F.P., Jalali S. 5—Natural fiber reinforced concrete. In: Fangueiro R., editor. Woodhead Publishing Series in Textiles, Fibrous and Composite Materials for Civil Engineering Applications. Woodhead Publishing; Sawston, UK: 2011. pp. 154–167. [Google Scholar]
  • 17.Ahmad J., Zhou Z. Mechanical Properties of Natural as well as Synthetic Fiber Reinforced Concrete: A Review. Constr. Build. Mater. 2022;333:127353. doi: 10.1016/j.conbuildmat.2022.127353. [DOI] [Google Scholar]
  • 18.Huang H., Yuan Y., Zhang W., Hao R., Zeng J. Bond properties between GFRP bars and hybrid fiber-reinforced concrete containing three types of artificial fibers. Constr. Build. Mater. 2020;250:118857. doi: 10.1016/j.conbuildmat.2020.118857. [DOI] [Google Scholar]
  • 19.Fraternali F., Ciancia V., Chechile R., Rizzano G., Feo L., Incarnato L. Experimental study of the thermo-mechanical properties of recycled PET fiber-reinforced concrete. Compos. Struct. 2011;93:2368–2374. doi: 10.1016/j.compstruct.2011.03.025. [DOI] [Google Scholar]
  • 20.Koo B.-M., Kim J.-H.J., Kim S.-B., Mun S. Material and Structural Performance Evaluations of Hwangtoh Admixtures and Recycled PET Fiber-Added Eco-Friendly Concrete for CO2 Emission Reduction. Materials. 2014;7:5959–5981. doi: 10.3390/ma7085959. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Zhang B., Luo Z., Yan L., Zhang Y., Wang Z., Yang Q., Li J., Zhang B., Luo Z., Yan L., et al. Study on the influence mechanism of polypropylene fiber on crack propagation of concrete with existing cracks under uniaxial compression. Theor. Appl. Fract. Mech. 2024;131:104429. doi: 10.1016/j.tafmec.2024.104429. [DOI] [Google Scholar]
  • 22.Jiang Y., Yan Y., Li T., Cao X., Yu L., Qi H. Comparison of the Mechanical Properties and Crack Expansion Mechanism of Different Content and Shapes of Brass-Coated Steel Fiber-Reinforced Ultra-High-Performance Concrete. Materials. 2023;16:2257. doi: 10.3390/ma16062257. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Magazzù A., Marcuello C. Investigation of Soft Matter Nanomechanics by Atomic Force Microscopy and Optical Tweezers: A Comprehensive Review. Nanomaterials. 2023;13:963. doi: 10.3390/nano13060963. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Wang J., Dai Q., Si R., Guo S. Mechanical, durability, and microstructural properties of macro synthetic polypropylene (PP) fiber-reinforced rubber concrete. J. Clean. Prod. 2019;234:1351–1364. doi: 10.1016/j.jclepro.2019.06.272. [DOI] [Google Scholar]
  • 25.Rahla K.M., Mateus R., Bragança L. Comparative sustainability assessment of binary blended concretes using Supplementary Cementitious Materials (SCMs) and Ordinary Portland Cement (OPC) J. Clean. Prod. 2019;220:445–459. doi: 10.1016/j.jclepro.2019.02.010. [DOI] [Google Scholar]
  • 26.Slag Cement Association. 2024. [(accessed on 21 August 2024)]. Available online: www.slagcement.org.
  • 27.Kashima S., Sakamoto M., Okada S., Iho T., Nakagawa Y. Proceedings, 4th CANMET/ACI International Conference. Volume 2. Special Publication; Istanbul, Turkey: 1992. Application of high slag and fly ash, low-heat cement to an-tiwashout underwater concrete: Fly ash, silica fume, slag, & natural pozzolans in concrete; pp. 1601–1619. [Google Scholar]
  • 28.Gomes L. Sydney Harbour Tunnel—Structure of the Immersed tube section. Tunn. Undergr. Space Technol. 1991;6:221–226. doi: 10.1016/0886-7798(91)90069-G. [DOI] [Google Scholar]
  • 29.Standard Specification for Concrete Aggregates. ASTM International; West Conshohocken, PE, USA: 2016. [Google Scholar]
  • 30.Standard Specification for Portland Cement. ASTM International; West Conshohocken, PE, USA: 2016. [Google Scholar]
  • 31.Standard Specification for Slag Cement for Use in Concrete and Mortars. ASTM International; West Con-shohocken, PE, USA: 2017. [Google Scholar]
  • 32.Standard Test Methods for Fiber Reinforced Concrete. China Planning Press; Beijing, China: 2010. [Google Scholar]
  • 33.Standard Method of Test for Resistance of Concrete to Chloride Ion Penetration. American Association of State and Highway Transportation Officials; Washington, DC, USA: 2002. [Google Scholar]
  • 34.Concrete, Hardened: Accelerated Chloride Penetration. Nordtest; Espoo, Finland: 1995. [Google Scholar]
  • 35.Hong K., Hooton R. Effects of cyclic chloride exposure on penetration of concrete cover. Cem. Concr. Res. 1999;29:1379–1386. doi: 10.1016/S0008-8846(99)00073-3. [DOI] [Google Scholar]
  • 36.Andrade C., Climent M.A., de Vera G. Procedure for calculating the chloride diffusion coefficient and surface concentration from a profile having a maximum beyond the concrete surface. Mater. Struct. 2015;48:863–869. doi: 10.1617/s11527-015-0543-4. [DOI] [Google Scholar]
  • 37.Wang T., Gao X., Li Y., Liu Y. An orthogonal experimental study on the influence of steam-curing on mechanical properties of foam concrete with fly ash. Case Stud. Constr. Mater. 2024;20:e02665. doi: 10.1016/j.cscm.2023.e02665. [DOI] [Google Scholar]
  • 38.Mori T. Taguchi Methods Benefits, Impacts, Mathematics, Statistics, and Applications. ASME Press; West Conshohocken, PE, USA: 2011. [Google Scholar]
  • 39.Vejmelková E., Pavlíková M., Keršner Z., Rovnaníková P., Ondráček M., Sedlmajer M., Černý R. High performance concrete containing lower slag amount: A complex view of mechanical and durability properties. Constr. Build. Mater. 2009;23:2237–2245. doi: 10.1016/j.conbuildmat.2008.11.018. [DOI] [Google Scholar]
  • 40.Munjal P., Hau K.K., Arthur C.C.H. Effect of GGBS and curing conditions on strength and microstructure properties of oil well cement slurry. J. Build. Eng. 2021;40:102331. doi: 10.1016/j.jobe.2021.102331. [DOI] [Google Scholar]
  • 41.Chen L., Chen X., Liu Z., Lu K., Liu J., Wang Z. Mechanical properties of macro-synthetic fiber reinforced rubber concrete under uniaxial loading. Constr. Build. Mater. 2024;445:137821. doi: 10.1016/j.conbuildmat.2024.137821. [DOI] [Google Scholar]
  • 42.Romualdi J.P., Mandel J.A. Tensile Strength of concrete Affected by Unigormly Distributed and Closely Spaced Short Lengths of wire Reinforcement. ACI J. Proc. 1964;61:657–672. doi: 10.14359/7801. [DOI] [Google Scholar]
  • 43.Johnston C.D. Fiber-Reinforced Cements and Concretes (Advances in Concrete Technology) Taylor & Francis; New York, NY, USA: 2000. [Google Scholar]
  • 44.Florea M., Brouwers H. Modelling of chloride binding related to hydration products in slag-blended cements. Constr. Build. Mater. 2014;64:421–430. doi: 10.1016/j.conbuildmat.2014.04.038. [DOI] [Google Scholar]
  • 45.Liu J., Jia Y., Wang J. Calculation of chloride ion diffusion in glass and polypropylene fiber-reinforced concrete. Constr. Build. Mater. 2019;215:875–885. doi: 10.1016/j.conbuildmat.2019.04.246. [DOI] [Google Scholar]
  • 46.Chen W., Zhu H., He Z., Yang L., Zhao L., Wen C. Experimental investigation on chloride-ion penetration resistance of slag containing fiber-reinforced concrete under drying-wetting cycles. Constr. Build. Mater. 2020;274:121829. doi: 10.1016/j.conbuildmat.2020.121829. [DOI] [Google Scholar]
  • 47.Song L., Sun W., Gao J. Time dependent chloride diffusion coefficient in concrete. J. Wuhan Univ. Technol. Sci. Ed. 2013;28:314–319. doi: 10.1007/s11595-013-0685-6. [DOI] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The original contributions presented in the study are included in the article, further inquiries can be directed to the corresponding author.


Articles from Materials are provided here courtesy of Multidisciplinary Digital Publishing Institute (MDPI)

RESOURCES