Skip to main content
RSC Advances logoLink to RSC Advances
. 2024 Nov 1;14(47):34855–34867. doi: 10.1039/d4ra06276k

Study on the sorption and desorption behavior of La3+ and Bi3+ by bis(2-ethylhexyl)phosphate modified activated carbon

Hongshan Zhu a,b,c, Stephan Heinitz a, Koen Binnemans b, Steven Mullens c, Thomas Cardinaels a,b,
PMCID: PMC11528331  PMID: 39493547

Abstract

The separation of 213Bi from its parent radionuclide 225Ac via radionuclide generators has proven to be a challenge due to the limited performance of the current sorbents. This study evaluated the separation performance of La3+ (as a surrogate for 225Ac) and Bi3+ using bis(2-ethylhexyl)phosphate monofunctionalized activated carbon (HDEHP/AC). The potential applications of phosphate groups as active sites and the carbon structure as a sorbent support were confirmed and validated. Various factors, including pH values, salt concentration, halide ions, contact time, solid-to-liquid ratio, initial La3+/Bi3+ concentration, and gamma irradiation were examined through batch sorption experiments in both single and binary systems. HDEHP/AC had a high sorption capacity for La3+via electrostatic attraction, with the sorption data fitting well to the pseudo-second-order kinetic equation and Langmuir model. The sorption performance of La3+ on HDEHP/AC was minimally affected as the NaCl/NaI concentrations increased at pH = 2, whereas the sorption capacity for Bi3+ decreased significantly. Additionally, selective desorption of La3+ and Bi3+ was achieved using HNO3 and NaI solutions, respectively. These results backed up by a conceptual separation process point toward a potential use of these materials in a direct/inverse 225Ac/213Bi radionuclide generator. Further optimization of the material and separation process will be required to bring this class of promising materials into an actual generator for medical applications.


The separation of 213Bi from its parent radionuclide 225Ac via radionuclide generators has proven to be a challenge due to the limited performance of the current sorbents.graphic file with name d4ra06276k-ga.jpg

1. Introduction

The short-lived radionuclide 213Bi (t1/2 = 45.61 min) has received increasing attention for targeted alpha therapy for cancer treatment due to its favorable physical and radiobiological properties.1–3 It undergoes a series of alpha- and beta-decays to the near-stable isotope 209Bi (t1/2 = 1.9 × 1019 years), without long-lived intermediates.4,5 Specifically, the decay of 213Bi, with a branching ratio of 97.86%, leads to a pure alpha-emitter 213Po (t1/2 = 3.708 μs), which emits high-energy alpha-particles (approximately 8 MeV).5,6213Bi-radiopharmaceutical plays a crucial role in delivering a high radiation dose to the targeted cancer cells.7 Currently, 213Bi is produced directly by the decay of the relatively long-lived radionuclide 225Ac (t1/2 = 9.920 days), which can be subsequently separated by radionuclide generators.1,8 However, the separation of 213Bi from 225Ac occurs in harsh conditions, posing stringent requirements on the performance and life-time of the sorbents used in the generators. Despite the fact that a range of sorbents have been investigated for this application, issues of low resistance to radiolysis and poor chemical stability make the separation of medical grade 213Bi in many cases a challenge.9–11 Considering these limitations, the development of alternative sorbents and the optimization of the related separation process are of great importance for the further development and implementation of targeted 213Bi therapy.9

Understanding the interactions between active sorption sites and radionuclides is a key strategy for developing alternative materials and optimizing the separation process.3,12 Previous studies have shown that 225Ac3+ can be tightly adsorbed onto organic resins with sulfonic acid groups (e.g., AG MP-50 and Dowex 50W-X8) through electrostatic attraction and ion exchange. Also, the desorption of 213Bi3+ can be achieved by elution with halide anions (e.g., I and Cl).13,14 However, the life-time of these materials is limited to about 1 day, due to the radiolysis-induced the scission of sulfonic acid groups and the changes in cross-linking of their macromolecular backbone.9,11,13,15 Moreover, a very high concentrations of acids such as HNO3 or HCl (e.g., 8 mol L−1 HNO3) should be used to recycle the undecayed 225Ac3+ from the column due to the strong affinity of the sulfonic acid group for 225Ac3+, possibly impacting the further reuse of 225Ac3+.16

The sorption and desorption mechanisms of carbon materials with carboxylic groups for La3+/Ac3+/Bi3+ were revealed in our previous studies. These materials have shown a potential for the selective sorption performance of Bi3+ over La3+/Ac3+ under a low pH value (e.g., pH 1–2) and a high salt concentration (e.g., 2–3 mol L−1 NaNO3). Although a series desorption experiments have done to discover an eluent to selective desorption of Bi3+, the contamination of La3+/Ac3+ has also been eluted. Therefore, due to the lack of a suitable eluent, it remains challenging to use these materials in direct generators.

Phosphorus-containing groups, such as phosphonic, phosphoric, and phosphinic acid groups, are known for their interaction with metal ions. Sorbent materials comprising such functional groups have been extensively studied due to their affinity towards to rare earth elements and actinides ions, with high selectivity towards the hard Lewis acid cations, especially lanthanides.17–22 Another benefit of phosphorus-containing groups is their higher radiation stability compared to sulfonic acid groups.23 One approach to synthesize such sorbents consists in the impregnation of an active phase (extractants) into a solid support.24–28 Despite the diversity in extractants and the nature of the solid support, only a few studies have systematically examined their potential use in 225Ac/213Bi generators. Wu et al. explored the separation performance of actinide (AC) resin, which is composed of P,P′-di(2-ethylhexyl)methanediphosphonic acid (H2DEH[MDP]) and silica matrix, for use in direct 225Ac/213Bi generators.29 However, the relatively low radiation stability of silica and H2DEH[MDP] has limited their application, together with the observation of silica leaching at a low pH.9,30,31 Furthermore, AC resin has shown a strong affinity for 225Ac even in a relatively high acidic solution, which may hinder the recycling and reuse of undecayed 225Ac3+ from the AC resin.21,29 Interestingly, Horwitz et al. reported that the sorption of Ac3+ onto di(2-ethylhexyl)orthophosphoric acid as the stationary phase on Celite was significantly low in 0.1 mol L−1 HNO3 solutions.32 Ondrák et al. reported the use of α-ZrP-PAN composite in a direct 225Ac/213Bi radionuclide generator, achieving 213Bi yield of 77–96% in a 2.8 mL.33 The elution was performed using 10 mM DTPA. However, the detailed separation mechanism of this material was not examined. Typically, the eluent should ideally be salt, which can be easily chelated by other chelators. Ostapenko et al. also found that most La3+ could be eluted by 0.1 mol L−1 HNO3 solutions from Ln resin (di(2-ethylhexyl)phosphoric acid (HDEHP) immobilized onto a solid support).27 Thus, the use of phosphate/phosphoric acid functional groups is expected to be favorable for the recycling and reuse of undecayed 225Ac3+.

The selection of solid support for the extractants in a generator column is also critical, with high requirements on their radiolytic and chemical stability.26,34 Various materials have been developed as solid supports for the immobilization of extractants, such as silica, polymer resins, powdered glass, and activated carbon.24,26,31,35,36 Among these, activated carbon materials have shown to be particularly attractive due to their large surface area, high porosity, stable pore structure, and good stability.37 However, experiments are still needed to explore the separation mechanism using such materials. Therefore, this study explores the use of bis(2-ethylhexyl)phosphate (Scheme 1) monofunctionalized activated carbon (HDEHP/AC) as a sorbent for the Ac3+ (or its surrogates)/Bi3+ separation. The primary focus was to demonstrate the performance of such phosphate monofunctionalized carbon surface as a model, allowing the unambiguous evaluation of the performance/influence of the phosphate group.

Scheme 1. Suggested structure of HDEHP.

Scheme 1

The physical and chemical properties of HDEHP/AC were characterized by various techniques such as scanning electron microscopy (SEM), diffuse reflectance infrared Fourier transformations (DRIFT), N2 sorption, elemental analysis, and inductively coupled plasma optical emission spectroscopy (ICP-OES). A series of batch experiments were conducted to investigate the separation behavior of HDEHP/AC for La3+ and Bi3+ under various influencing factors (e.g., pH values, salt concentration, contact time, initial concentrations of metal ions, gamma-ray irradiation), and the conceptual design of 225Ac/213Bi separation process was discussed. The findings of this study are expected to contribute to the development and fabrication of alternative materials for use in 225Ac/213Bi radionuclide generators.

2. Experimental section

2.1. Materials and reagents

La(NO3)3·6H2O (99.99%), Bi(NO3)3·5H2O (98%), NaNO3 (≥99.0%), and HNO3 (≥65%) were purchased from Sigma-Aldrich. HCl (37%) was purchased from Fisher Scientific. NaCl (≥99.5%), NaOH (≥99.0%), and bis(2-ethylhexyl)phosphate modified activated carbon (902 470) were purchased from Merck. Milli-Q water (18.2 MΩ cm @ 25 °C) was used in the experiments. All chemicals in this study were used without further purification.

2.2. Batch sorption experiments

Stock solutions with La3+ and Bi3+ were prepared by dissolving appropriate amounts of La(NO3)3·6H2O (99.99%) and Bi(NO3)3·5H2O (98%) in 0.01 and 0.30 mol L−1 HNO3 solutions, respectively, to obtain a concentration of 100 mg L−1 for each ion. Then, the NaOH and HNO3 were utilized to adjust the pH values of the solutions. Batch sorption experiments were carried out in 50 mL plastic centrifuge tubes with a suitable mass of HDEHP/AC added into a 30 mL of the liquid phase. To investigate the solid-to-liquid ratio, HDEHP/AC with different mass values was mixed with a given concentration of La3+ and Bi3+ solution (30 mL). Various concentrations of NaNO3/NaCl/NaI were added to examine the effect of salt concentrations and halide ions. Kinetic time was investigated by controlling the shaking time (2–180 min) in single and binary systems. Sorption isotherms were measured by increasing the initial concentrations of La3+ and Bi3+ in both single and binary systems. Except where stated otherwise, the reaction suspension was shaken at 140 rpm in a shaker for 24 hours at room temperature. The separation of sorbent from liquid phase was performed using 0.45 μm PTFE syringe filters, and the La3+ and Bi3+ concentrations in the liquid phase were measured by ICP-MS/ICP-AES.

The sorption capacity for 225Ac was also investigated by using a 30 mL liquid phase containing 100 kBq 225Ac, 10 μmol L−1 La3+, and 10 μmol L−1 Bi3+ with 60 or 400 mg HDEHP/AC as the solid phase. The reaction suspension was shaken at 140 rpm for 2 hours, and the remaining steps were similar to those described above. The activities of 221Fr and 213Bi were measured by a high-purity germanium (HPGe, Princeton Gamma Tech) detector, while the activity of 225Ac was calculated based on the relation between 225Ac and 221Fr/213Bi.34

2.3. Desorption experiments

The liquid solution used in the sorption process was composed of 10 μmol L−1 La3+, and 10 μmol L−1 Bi3+. Then, 400 mg of HDEHP/AC was added to the liquid solution, and the reaction suspension was shaken at 140 rpm in a shaker for 24 hours at room temperature. Afterwards, a 1.0 mL of different HNO3 solution concentrations was added into the reaction suspension, which was shaken for 24 h. Finally, the separation of sorbent from liquid was performed using 0.45 μm PTFE syringe filters, and the La3+ and Bi3+ concentrations in the liquid phase were measured by ICP-MS/ICP-AES. For the desorption process with NaI eluate, after the sorption process, 0.15–3 mL of NaI solution was added into the reaction suspension to adjust the concentration of NaI within 0.005–0.45 mol L−1.

2.4. Stability experiments

To determine its chemical stability in an aqueous solution, dry HDEHP/AC with different mass values (e.g., 100, 200, 300, 400, and 500 mg) was immersed into 40 mL of 0.01–0.5 mol L−1 HNO3 solution in a 50 mL plastic centrifuge tube, and then the plastic centrifuge tubes were shaken at 180 rpm for 150 hours. HDEHP/AC was removed using 0.45 μm PTFE membrane filters, and then the HDEHP/AC residue was dried in an oven at 70 °C. The mass weight of P for the HDEHP/AC was measured by ICP-OES.

To determine its radiation stability, the dry HDEHP/AC was placed into a glass vial and then irradiated with gamma rays from a 60Co source (BRIGITTE, SCK CEN). The absorbed dose for HDEHP/AC was 862 ± 121 kGy with a dose rate of 8.9 kGy h−1, and its radiation stability was investigated by conducting batch sorption experiments.

2.5. Characterization

The surface morphology of HDEHP/AC was analyzed by SEM (FEI Nova NanoSEM 450), and XRD (X'Pert Pro, PAN analytical, Cu radiation source) was used to investigate the carbon structure. Elemental analysis (Vario EL and Oxy Cubes) and ICP-OES (Agilent Technologies Inc. – 5100) were performed to quantify the C, O, H, and P element amounts. The diffuse reflectance infrared Fourier transformations (DRIFT) spectroscopy (Nicolet 6700) with an in situ DRIFT accessory type ‘Harrick Praying Mantis’ was used to identify the surface functional groups. Thermal stability was determined by TGA (Netzsch STA 449 F3).

2.6. Data analysis

The sorption percentage R (%), sorption amount qe (μmol g−1), distribution coefficient Kd (mL g−1), and desorption percentage D (%) were expressed as follows:

2.6. 1
2.6. 2
2.6. 3
2.6. 4
2.6. 5
2.6. 6
2.6. 7
2.6. 8

where m (g) represents the mass of the sorbent. V (mL) refers to the liquid phase volume during the sorption process, Vd (mL) represents the liquid phase volume in the desorption process, Co (μmol L−1) and Ce (μmol L−1) denote the starting and final concentrations of metal ions during the sorption process, respectively. Cd (μmol L−1) is the final concentration of metal ions in the desorption process. no (μmol) and nd (μmol) represent the amount of La3+ or Bi3+ sorption on the sorbent after the sorption and desorption processes, respectively.

The pseudo-first order (eqn (9)), pseudo-second order (eqn (10)), intraparticle diffusion (eqn (11)) and Elovich (eqn (12)) models were applied to fit sorption kinetic data:38–41

qt = qe(1 − ek1t) 9
2.6. 10
qt = KIPDt1/2 + C 11
2.6. 12

where k1 (min−1), k2 (g μmol−1 min−1), KIPD (μmol g−1 min−1/2) refer to the sorption rate constants of the kinetic equations. t (min) is the sorption time and qt (μmol g−1) represents the amount of metal ions adsorbed at time t. C (μmol g−1) is related to the thickness of boundary layer. α (μmol g−1 min−1) and β (g μmol−1) are known as the Elovich coefficients.

The Langmuir and Freundlich models can respectively be expressed as follows eqn (13) and eqn (14), respectively:41–43

2.6. 13
2.6. 14

where KL (L μmol−1) is a constant of the Langmuir equation, qmax (μmol g−1) represents the maximum amount of metal ions adsorbed onto HDEHP/AC. KF (μmol1−n Ln g−1) and 1/n are the Freundlich constants related to the sorption capacity and the sorption intensity, respectively.

3. Results and discussion

3.1. Characterization

HDEHP/AC was characterized by complementary techniques to investigate its physical–chemical properties before testing its performance to separate Bi3+ from La3+/Ac3+. The SEM image revealed irregularly shaped HDEHP/AC grains that ranged from several micrometers to nearly a hundred micrometers in size (Fig. 1a). The XRD pattern (Fig. 1b) exhibited a broad peak centered at around 2θ = 20–23°, indicating an amorphous or disordered carbon structures.44,45 Another broad and weak peak was observed at around 2θ = 43–44°, which was attributed to an axis of the graphite structure.44,45

Fig. 1. SEM image (a), XRD pattern (b), FT-IR spectrum (c), N2 sorption curve (d), TGA curve (e), and phosphorus leaching (f) of HDEHP/AC.

Fig. 1

The elemental analysis results (Table S1) show that the percentage of P in the HDEHP/AC was 2.42 wt%, in addition to 82.8 wt% C, 3.14 wt% H, and 7 wt% O. Furthermore, the DRIFT spectrum (Fig. 1c) of HDEHP/AC contained characteristic bands at 1242 and 1028 cm−1, which were assigned to the P Created by potrace 1.16, written by Peter Selinger 2001-2019 O and P–O–C stretching modes, respectively.46,47 These results indicate that the HDEHP was immobilized onto the activated carbon structure. The introduction of HDEHP on the surface of activated carbons caused a decrease in their specific surface area from approximately 1000 m2 g−1 (as reported by Merck) to approximately 528 m2 g−1, as shown in Table S1 and Fig. 1d. The TGA curve (Fig. 1e) shows that the thermal decomposition of HDEHP/AC began at 230 °C. The mass loss of HDEHP/AC was about 18% up to 400 °C, which was due to the thermal decomposition of HDEHP. Beyond this point, the decomposition rate decreased before reaching ∼850 °C, indicating that the precursor of activated carbon probably had undergone a carbonization at high temperatures, particularly above 800 °C. Based on above characterization results, there are few other functional groups on the surface of activated carbon, and the primary functional group of HDEHP/AC is the phosphate group. Thus, HDEHP/AC can be used as a sorbent to examine the function of phosphate group and the carbon structure.

For the sorbents, the loss of extractants from the impregnated materials into the liquid phase, due to the dissolution effect and/or mechanical force, was a concern.48 Therefore, leaching tests have been performed by contacting HDEHP/AC at different solid-to-liquid ratios and in the 0.01–0.5 mol L−1 HNO3 solutions for 150 h. Fig. 1f shows phosphorous content in HDEHP/AC after these leaching test, clearly demonstrating that HDEHP is not released from the carbon matrix in such conditions. A further possible reason for this stability was the low solubility of HDEHP in water and the weak HNO3 solutions.49

3.2. Sorption performance

3.2.1. Effect of pH

The pH has a significant impact on both the metal speciation and the protonation/deprotonation of the phosphate groups on the HDEHP/AC.34,50,51 The speciation of La3+ and Bi3+ as a function of pH was calculated in our previous work.34 Briefly, La3+ and Bi3+ ions are present as cations in aqueous solutions when the pH value is below 2.0. Fig. 2a shows the effect of pH on the sorption of La3+/Bi3+ onto HDEHP/AC in the binary system (both La3+ and Bi3+) with a solid-to-liquid ratio of 1 or 2 g L−1, respectively.

Fig. 2. Effect of pH on the sorption percentage and distribution coefficient (Kd) of HDEHP/AC for La3+ and Bi3+ in the binary system (a). (Co (La3+) = 10 μmol L−1 and Co (Bi3+) = 10 μmol L−1, solid-to-liquid ratio = 1 g L−1 for (1) or 2 g L−1 for (2), t = 24 h). The effect of pH on the sorption percentage of HDEHP/AC for La3+ in the single system (b). (Co (La3+) = 10 μmol L−1, solid-to-liquid ratio = 1 g L−1, t = 24 h).

Fig. 2

The La3+ sorption percentage and Kd values rapidly increased at pH > 1.3. The sorption of La3+ onto the HDEHP/AC was primarily due to electrostatic attraction and surface complexation, which is associated with the deprotonated functional groups from HDEHP, known for its pKa of ∼1.47.52 Furthermore, as pH increases, the competitive sorption of decreased H+ on HDEHP decrease. Increasing the solid-to-liquid ratio (to 2 g L−1) shifted the increase in sorption capacity to lower pH (by merely 0.2 units), but the overall relationship was not impacted. This reconfirms that the sorption of La3+ onto HDEHP/AC was due to the electrostatic attraction/surface complexation and the decreased competitive effect of H+. The pH relation also indicates that the La3+ is expected to be desorbed via ion exchange with H+ in relatively low-pH solutions.

In contrast, the Bi3+ sorption percentage onto HDEHP/AC increases significantly at a lower pH compared to the increase in sorption capacity for La3+ and reaches more than 80% from a pH of 0.9. Increasing the pH further leads to a gradual increase in sorption capacity and related Kd values, due to the strong affinity of Bi3+ for the sorption active sites. This was probably due to the electrostatic repulsion between Bi3+ and protonated functional groups as well as the competitive sorption of excess H+ ions. Increasing the solid-to-liquid ratio leads to a minor shift to higher sorption capacities in the pH range between 0.6 and 1.6.

La3+ sorption was also examined over a broad pH range under a single system, as shown in Fig. 2b. The high sorption capacity of HDEHP/AC toward La3+ could be achieved at a higher pH value.

Based upon the measured sorption capacity, some estimates can be made for an actual 225Ac/213Bi generator. In case 4 GBq 225Ac is loaded onto a column, which corresponds to 8.279 nmol of 225Ac, only a minor amount of HDEHP/AC as sorbent should be sufficient for full sorption. The pH relationship also offers some insight in the potential use of HDEHP/AC. As selective Bi3+ sorption occurs at low pH (pH < 1), HDEHP/AC could be used in an inverse generator. For a direct generator approach, the pH and the solid-to-liquid ratio can be increased to facilitate the sorption of both Bi3+ and La3+.

According to above results, we inferred that controlling the separation pH (e.g., pH = 0.6) is expected to facilitate the selective uptake of Bi3+ from a La3+(Ac3+)/Bi3+ mixed solution onto the inverse separation column filled with HDEHP/AC sorbent. The use of sorbents with phosphate functional groups in the inverse generators is expected to align with our previous research.34 For the direct separation column, when the pH > 2 or 3, a high sorption capacity for La3+ (Ac3+) onto HDEHP/AC is expected to be achieved by increasing the pH and solid-to-liquid ratio.

3.2.2. Effect of NaNO3 concentration

Fig. 3a presents impact of ionic strength on the separation of La3+/Bi3+ by varying the NaNO3 concentrations. The removal percentages and Kd values for La3+ gradually decreased as the concentration of NaNO3 increased from 0 to 1.0 mol L−1, attributed to the shrinkage of the electrical double layer and thus a weaker electrostatic attraction between La3+ and HDEHP/AC.53 The increased influence of ion competition with higher concentrations of interfering ions in the solution reduced the availability of La3+ ions for sorption. By contrast, the Kd values for the Bi3+ remained very high throughout the concentration range and appeared to be independent of the NaNO3 concentration, indicating that a different sorption mechanism is at play for Bi3+. Additionally, the La3+ sorption percentage increased as the solid-to-liquid ratio increased from 3 to 13.3 g L−1 (Fig. 3b). The sorption percentages and Kd values for La3+ were still greater than 90% and 103 mL g−1, respectively, when the NaNO3 solution was below 0.5 mol L−1 at pH = 2 with a solid-to-liquid ratio of 13.3 g L−1. This suggests that the negative effect of ionic strength could be attenuated by increasing the solid-to-liquid ratio.

Fig. 3. Effect of NaNO3 concentration on the sorption performance of HDEHP for La3+ and Bi3+ in the binary system with a solid-to-liquid ratio of 3 (a) or 13.3 g L−1 (b). (Co (La3+) = 10 μmol L−1 and Co (Bi3+) = 10 μmol L−1, pH = 2, t = 24 h).

Fig. 3

3.2.3. Effect of halide ion concentration

The influence of halide ions on the sorption performance of HDEHP/AC toward La3+/Bi3+ was examined using 0.1–1.0 mol L−1 NaCl and 0.1–0.5 mol L−1 NaI solutions. Fig. 4a shows that the Bi3+ sorption percentages decreased significantly as the NaCl concentration increased at pH = 2 and pH = 0.5, due to the formation of Bi–Cl complexes (e.g., [BiCl4]), which have a lower affinity for HDEHP/AC.54 This effect of decreasing sorption capacity is more pronounced at lower pH values, indicating that the H+ concentration was also an influencing factor. The La3+ sorption percentage at pH = 2 gradually decreased as the NaCl concentration increase, due to the influence of ionic strength, but remains higher than 80% even in the presence of 1 mol L−1 NaCl.

Fig. 4. Effect of NaCl (a) and NaI (b) concentration on the sorption performance of HDEHP for La3+ and Bi3+ in the binary system. (Co (La3+) = 10 μmol L−1 and Co (Bi3+) = 10 μmol L−1, solid-to-liquid ratio = 13.3 g L−1, t = 24 h).

Fig. 4

Also these results indicate the potential in a generator, in which Bi3+ can be selectively eluted from the column at a relatively high pH (e.g., pH = 2), with minimal effect on the La3+ sorption. One possible reason for this phenomenon was the electrostatic repulsion that likely occurred between the negatively charged Bi-anion complexes and the deprotonated functional groups, which were also negatively charged.54,55 Furthermore, lowering the pH could elute the high Bi3+ in a relatively low concentration of NaCl, but this process also resulted in the elution of most of the La3+ from HDEHP/AC.

The profound effect of chloride ions on the sorption performance is also noticed for iodide. Fig. 4b shows the very high La3+ sorption capacity (>98%) in the presence of NaI concentrations in the range of 0.1 to 0.5 mol L−1 (at pH = 2). Similar to NaCl, increasing the NaI concentration drastically decreases the Bi3+ sorption capacity, due to the formation of Bi-iodide complexes which seem to have an even lower affinity compared to the Bi-chloride complexes. In summary, the halide ions (e.g., Cl and I) are expected to selectively elute 213Bi from the direct 225Ac/213Bi columns, resulting in the electrostatic repulsion between the Bi-halide anions and the negatively charged phosphate groups.54,55

3.2.4. Effect of sorption time

The sorption kinetics of La3+ and Bi3+ onto the HDEHP/AC were determined by sorption experiments at time intervals in the range of 2–180 min. Fig. 5a presents of the evolution of the La3+/Bi3+ sorption percentages as a function of the contact time for single and binary systems. The sorption of La3+/Bi3+ onto HDEHP/AC rapidly increased within the first period (<30 min), which was attributed to the availability of sufficient active sites for La3+/Bi3+ sorption. Then, sorption slightly increased because of the depletion of Bi3+ from the solution and the limited accessible active sites for La3+. Additionally, the Bi3+ sorption capacity was noticeably higher compared to the La3+ sorption capacity.

Fig. 5. Effect of contact time on the sorption performance of HDEHP/AC for La3+/Bi3+ in the single (La/Bi) and binary (La + Bi) systems (a). Sorption kinetics of La3+ or Bi3+ onto HDEHP/AC in the single (b) and binary (c) systems (pseudo-first-order curve: dashed line, pseudo-second-order curve: solid line). Sorption kinetics of La3+ or Bi3+ onto HDEHP/AC in the single system (d) (intraparticle diffusion model: solid line, Elovich model: dashed line). (Co (La3+) = 10 μmol L−1 and/or Co (Bi3+) = 10 μmol L−1, solid-to-liquid ratio = 1 g L−1, pH = 2).

Fig. 5

The sorption of La3+ was distinctly higher in the single system than in the binary system at the corresponding time points, indicating that the presence of Bi3+ had a significant effect on the La3+ sorption. This was because most of the sorption sites were occupied by Bi3+. However, in practical applications, the concentration of Bi3+ is expected to be much lower than that of La3+ due to the high specific activity of 213Bi3+ compared to 225Ac3+. As such, the negative impact of Bi3+ on the La3+ sorption percentage would be less pronounced, as seen in Fig. 5a. By contrast, the Bi3+ sorption was not influenced by the presence of La3+, which was attributed to the high affinity of HDEHP/AC for Bi3+ as well as the fast kinetic interaction times.

Pseudo-first-order, pseudo-second-order, intraparticle diffusion and Elovich sorption kinetic models were applied to fit the experimental data and to obtain insight into the underlying sorption mechanism.39–41 The fitting parameters are shown in Table S2. In the single system (Fig. 5b), the pseudo-second-order equation had high correlation coefficient values that indicated its suitability for illustrating the sorption process of La3+ and Bi3+ onto the HDEHP/AC. A similar result was obtained in the binary system (Fig. 5c). Based on the pseudo-second-order equation, the qe (La3+) in the single system (5.590 μmol g−1) was higher than that in the binary system (4.069 μmol g−1), suggesting that competitive sorption occurred. There were no obvious changes in Bi3+ sorption, indicating the weak competition of La3+ for Bi3+. Furthermore, compared to the pseudo-first-order and pseudo-second-order models, the intraparticle diffusion model was not suitable for the kinetic results due to its low R2 value (Fig. 5d). Interestingly, the Elovich model provided a better fit the kinetic data of La3+ among the four models (Fig. 5d). Based on these comparisons, it can be concluded that the kinetic behavior for La3+ can be described by the Elovich model, while the pseudo-second-order is more appropriate for Bi3+.

3.2.5. Effect of initial La3+/Bi3+ concentration

The influence of starting La3+ and Bi3+ concentration on the sorption performance was also studied in the single/binary systems, and the relevant results are presented in Fig. 6a. The La3+ sorption onto HDEHP/AC increased rapidly as the initial concentration of La3+ increased and then increased slightly, which was ascribed to the saturation of active sorption sites. The sorption capacity of HDEHP/AC for La3+ was higher in the single system than in the binary system, attributed to the faster kinetics of the Bi3+ sorption leading to an occupation of the available sorption sites (competitive sorption of Bi3+ over La3+). Additionally, the sorption capacity and sorption percentages for Bi3+ were still very high across the entire range. Fig. 6b illustrates that the La3+ sorption percentages of HDEHP/AC decreased linearly with increasing La3+ and Bi3+ concentrations. However, this is unlikely to significantly affect 225Ac/213Bi separation in a direct generator as the loading amount of 225Ac in practical applications is low. Moreover, this finding suggests a useful strategy for the inverse generator, where La3+ absorbed on the column prior to loading 225Ac and 213Bi solution is expected to reduce the 225Ac sorption. The La3+ in the 213Bi eluate can then be purified using a guard column (e.g., AG MP-50 column). The Langmuir and Freundlich models were used to fit the La3+ data in the single system, with the curves shown in Fig. 6c and the relevant parameters presented in Table S3.41–43 The Langmuir model was more suitable to describe the La3+ sorption process than the Freundlich model according to the R2. This indicates that all of the active sites for La3+ had equal adsorption affinities and were energetically and sterically independent of the adsorbed quantity.41,56 The maximum La3+ sorption capacity of HDEHP/AC was 15.226 μmol g−1.

Fig. 6. Effect of initial concentration for La3+/Bi3+ sorption onto HDEHP/AC in the single (La/Bi) and binary (La + Bi) systems (a and b). Sorption isotherms of La3+ onto HDEHP/AC in the single system (Langmuir isotherm: solid line, Freundlich isotherms: dashed line) (c). (Solid-to-liquid ratio = 2 g L−1, pH = 2, t = 24 h).

Fig. 6

3.2.6. Effect of gamma-ray irradiation

The radiation stability of HDEHP/AC is also an important influencing factor that affects its performance as a sorbent material. In this study, HDEHP/AC was exposed to 862 ± 121 kGy under dry conditions to investigate its radiation stability. Fig. 7a and b shows the Kd values and sorption percentages upon the HDEHP/AC exposure to 0 and 862 kGy, respectively. The La3+ sorption percentage decreased, which was probably due to the cleavage of the C–C bond and the scission of the C–PO4 bond of the HDEHP/AC after exposure to gamma-radiation (Fig. 7c) as also illustrated in the previous studies23,26 However, there was no noticeable change in the sorption capacity of HDEHP/AC for Bi3+, due to the presence of sufficient sorption sites for Bi3+. Based on these findings, one potential approach to enhance the operation time of the generator would be to introduce a low density of phosphate groups into the carbon structure. This modification is expected to decrease radiation damage to sorbents when loaded with high-activity radioisotopes. The relatively fewer number of active sites may not pose a significant problem for 225Ac/213Bi generator columns, due to the low amount of 225Ac and 213Bi isotopes in practical applications. Another potential approach would involve reducing radiation damage and prolonging the lifetime of the generator, to minimize the contact time between the sorbents and 225Ac and its daughter nuclides. This could be achieved by eluting 225Ac from the column, as described in the following section.

Fig. 7. Effect of absorbed dose on the distribution coefficient (a) and sorption percentage (Kd) (b) of HDEHP/AC for La3+ and Bi3+ in the binary system. (Co (La3+) = 10 μmol L−1 and Co (Bi3+) = 10 μmol L−1, solid-to-liquid ratio = 2 g L−1, pH = 2, t = 24 h). Schematic illustration of scission of functional groups by gamma irradiation (c).

Fig. 7

3.2.7. 225Ac sorption behavior on HDEHP/AC

La3+ was used as a surrogate of Ac3+ due to similar sorption changes with varying HNO3 concentrations, as reported in previous studies on the La3+ and Ac3+ sorption.27 The similar sorption behaviors were possibly due to their stable valence charge (+3) in aqueous solution, hydrolysis properties, and absolute chemical hardness (15.4 eV for La3+, whereas 14.4 eV for Ac3+).57–59 However, it should be noted that the phosphate groups had a stronger sorption affinity toward La3+ than Ac3+. Herein, the sorption capacity of HDEHP/AC toward 225Ac3+ was also investigated by conducting batch sorption experiments, providing the reference sorption performance of 225Ac3+ on HDEHP/AC. Fig. 8 presents the increase in Ac3+ sorption percentage as pH increases, whereas the sorption capacity could also be improved with the increased solid-to-liquid ratio. Although the sorption capacity of Ac3+ onto these types of materials with phosphate groups was lower than that of La3+ sorption (see Fig. 2a), both exhibited similar sorption behaviors. Therefore, investigating La3+ sorption could still provide reliable guidance for Ac3+ sorption onto HDEHP/AC.

Fig. 8. Sorption percentage of HDEHP/AC towards 225Ac3+. (Ao = 100 kBq, Co (La3+) = 10 μmol L−1 and Co (Bi3+) = 10 μmol L−1, t = 2 h).

Fig. 8

3.3. Desorption performance

The recycling of 225Ac is also an essential step for the generator column, as most functional groups are susceptible to radiolytic damage. Additionally, in the direct system, reducing the contact time is an effective way to minimize the dose received by the sorbents. This study investigated the effectiveness of the HNO3 solution in desorbing La3+ from the HDEHP/AC. Fig. 9a shows that 0.1 mol L−1 HNO3 solution could desorb nearly 90% of the La3+, while almost all of the La3+ on HDEHP/AC could be desorbed using 0.2–0.3 mol L−1 HNO3 solution. Considering the influence of ionic strength, 225Ac could be readily reused with a salt concentration of less than 0.5 mol L−1. An interesting finding was the relatively low desorption capacity of Bi3+, suggesting the potential use of HNO3 for the selective desorption of 225Ac in the inverse generator. This step could improve the purity of 213Bi without significantly affecting its yield. Fig. 9b shows the desorption of Bi3+ from HDEHP/AC at pH = 2, using NaI solution. The results show that the desorption percentage of Bi3+ increased with the NaI concentration increasing, while there was no desorption efficiency for La3+. This indicates that the Bi3+ could be selectively desorbed.

Fig. 9. The desorption efficiency of La3+ and Bi3+ from the HDEHP/AC as of function of HNO3 (a) concentration and NaI concentration (pH = 2) (b).

Fig. 9

3.4. Preliminary column test

To evaluate the 225Ac/213Bi separation performance for practical applications, a column test is needed. However, commercial HDEHP/AC consisted of an irregular powder with a broad particle size range, making it difficult to increase the flow rate of the solution due to the high-pressure stacking. Nevertheless, a preliminary column test was conducted to offer some guidance for further material design. The 213Bi yield was approximately 50% in the 5 mL of 1 mol L−1 NaI/0.01 mol L−1 HNO3 eluate, with the 225Ac impurity being less than 0.04%. The 213Bi yield was lower compared to previously used materials, due to the high surface areas of the carbon structures. Additionally, a high mass value of HDEHP/AC was used during the desorption process, resulting in low desorption efficiency. However, this result also indicates that the grafting of phosphate functional groups onto the carbon materials could serve as a potential candidate for use in the direct 225Ac/213Bi generators.

3.5. Conceptual separation of 225Ac and 213Bi

The findings of this study suggest that the phosphate groups and carbon structure had the potential to serve as the active sites and support, respectively, for the 213Bi separation. Although commercial HDEHP/AC was unsuitable for practical use, the data obtained could serve as a reference for designing materials and optimizing separation processes. Shaped HDEHP/AC materials with a suitable range of particle sizes could be fabricated and utilized for 225Ac/213Bi separation. The conceptual separation of 225Ac and 213Bi based upon this material can be envisioned in several approaches.

The first approach is a 2-column direct generator, as shown in Fig. 10a. The detailed separation process can be seen in the experimental section. The second column can be used for the further purification of 213Bi eluate. An alternative use in a direct generator, consists in the removal of two-thirds of the sorbent from the column for adsorbing 225Ac and 213Bi through batch experiments, and then the sorbents with 225Ac/213Bi can be placed back into the column.29 A guard column with AG MP-50 or its analog could also be employed to improve the purity of 213Bi. Before the sorbents experienced severe damage, the 225Ac could be readily eluted from HDEHP/AC using relatively weak acidic solutions compared to the AG MP-50.

Fig. 10. Conceptual separation process of the direct generator (a), inverse generator (b), and a possible method (c).

Fig. 10

The material holds also potential to be used in an inverse generator (see Fig. 10b). Bi3+ could be selectively adsorbed onto HDEHP/AC by adjusting the pH and salt concentrations. The purity of Bi3+ could be further improved by using 0.1–0.2 mol L−1 HNO3 to elute the possibly adsorbed 225Ac3+ before the 213Bi eluting step. This method could significantly reduce the radiolytic damage for the sorbents. Additionally, this separation is similar to the PNNL Bi-generator concept.11

HDEHP/AC also showed selective sorption of 225Ac, with minimal sorption capacity for Bi-halide complexes, as shown in Fig. 10c. When the 225Ac and 213Bi-halide complexes pass through the column, the 225Ac can be selectively adsorbed onto the column. The 213Bi can be obtained in a vial. Subsequently, the 225Ac can be eluted from the column for 213Bi ingrowth for use in the next cycle.

4. Conclusions

The study investigated the sorption and desorption behaviors of La3+ (as an analog for 225Ac) and Bi3+ by HDEHP/AC for the selective separation of 213Bi in medical applications. HDEHP/AC exhibited sorption toward La3+via electrostatic attraction and surface complexation with a maximum sorption capacity of about 15 μmol g−1 (from the Langmuir model) at pH = 2, which could be further increased by increasing the pH values. The sorption of La3+ onto HDEHP/AC could be fitted by the Elvoich model. Further research shows that the La3+ sorption capacity decreased slightly or did not change as the NaCl and NaI concentrations increased, in contrast with the Bi3+ sorption capacity which decreased rapidly for Bi3+ owing to the formation of Bi-halide complexes. The desorption results show that the La3+ could be completely eluted from the sorbent via 0.2–0.3 mol L−1 HNO3 solutions from HDEHP/AC, which was likely to be beneficial in reducing the radiation damage to the direct column and for recycling undecayed 225Ac. Additionally, Bi3+ could be selectively adsorbed by HDEHP/AC at a low pH and relatively high NaNO3 concentration, and the HNO3 could be used to further improve the 213Bi purity in the inverse generator. Simultaneously, large amounts of Bi3+ are expected to be eluted by halide ions at a low pH (e.g., pH = 0.5) from the inverse columns. Therefore, HDEHP/AC showed promise for application in direct and inverse 225Ac/213Bi generators. However, commercial HDEHP/AC is an irregular powder with a broad particle size range and a high specific surface area, limiting its application in column chromatography. Further research should be dedicated towards the development if synthesis routes to graft phosphate groups onto shaped carbon materials (or alternatives) and to optimize the separation process conditions.

Data availability

The data supporting this article have been included as part of the ESI.

Conflicts of interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Supplementary Material

RA-014-D4RA06276K-s001

Acknowledgments

The SCK CEN and VITO are acknowledged for funding. Furthermore, the authors would like to acknowledge the technical assistance of P. Verheyen (ICP-MS), K. Raymond (SEM), K. Zhang & V. Meynen (DRIFT), M. Mertens (XRD), A. De Wilde (N2 sorption and TGA-MS), and J. De Wit (CHN analysis).

Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d4ra06276k

References

  1. Sgouros G. Bodei L. McDevitt M. R. Nedrow J. R. Radiopharmaceutical therapy in cancer: clinical advances and challenges. Nat. Rev. Drug Discov. 2020;19:589–608. doi: 10.1038/s41573-020-0073-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Targeted Alpha Therapy Working Group Parker C. Lewington V. Shore N. Kratochwil C. Levy M. Linden O. Noordzij W. Park J. Saad F. Targeted Alpha Therapy, an Emerging Class of Cancer Agents: A Review. JAMA Oncol. 2018;4:1765–1772. doi: 10.1001/jamaoncol.2018.4044. [DOI] [PubMed] [Google Scholar]
  3. Zhu H. Heinitz S. Binnemans K. Mullens S. Cardinaels T. 225Ac/213Bi radionuclide generators for the separation of 213Bi towards clinical demands. Inorg. Chem. Front. 2024;11:4499–4527. doi: 10.1039/D4QI00326H. [DOI] [Google Scholar]
  4. Morgenstern A. Apostolidis C. Kratochwil C. Sathekge M. Krolicki L. Bruchertseifer F. An Overview of Targeted Alpha Therapy with 225Actinium and 213Bismuth. Curr. Rad. 2018;11:200–208. doi: 10.2174/1874471011666180502104524. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Robertson A. K. H. Ramogida C. F. Schaffer P. Radchenko V. Development of 225Ac Radiopharmaceuticals: TRIUMF Perspectives and Experiences. Curr. Rad. 2018;11:156–172. doi: 10.2174/1874471011666180416161908. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Ahenkorah S. Cassells I. Deroose C. M. Cardinaels T. Burgoyne A. R. Bormans G. Ooms M. Cleeren F. Bismuth-213 for Targeted Radionuclide Therapy: From Atom to Bedside. Pharmaceutics. 2021;13:599. doi: 10.3390/pharmaceutics13050599. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Kratochwil C. Giesel F. L. Bruchertseifer F. Mier W. Apostolidis C. Boll R. Murphy K. Haberkorn U. Morgenstern A. 213Bi-DOTATOC receptor-targeted alpha-radionuclide therapy induces remission in neuroendocrine tumours refractory to beta radiation: a first-in-human experience. Eur. J. Nucl. Med. Mol. Imag. 2014;41:2106–2119. doi: 10.1007/s00259-014-2857-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Ermolaev S. Skasyrskaya A. Vasiliev A. A Radionuclide Generator of High-Purity Bi-213 for Instant Labeling. Pharmaceutics. 2021;13:914. doi: 10.3390/pharmaceutics13060914. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Vasiliev A. N. Zobnin V. A. Pavlov Y. S. Chudakov V. M. Radiation Stability of Sorbents in Medical 225Ac/213Bi Generators. Solvent Extr. Ion Exch. 2020;39:353–372. doi: 10.1080/07366299.2020.1846892. [DOI] [Google Scholar]
  10. McDevitt M. R. Finn R. D. Sgouros G. Ma D. Scheinberg D. A. An 225Ac/213Bi generator system for therapeutic clinical applications: construction and operation. Appl. Radiat. Isot. 1999;50:895–904. doi: 10.1016/S0969-8043(98)00151-1. [DOI] [PubMed] [Google Scholar]
  11. Bray L. A. Tingey J. M. DesChane J. R. Egorov O. B. Tenforde T. S. Wilbur D. S. Hamlin D. K. Pathare P. M. Development of a Unique Bismuth (Bi-213) Automated Generator for Use in Cancer Therapy. Ind. Eng. Chem. Res. 2000;39:3189–3194. doi: 10.1021/ie990068r. [DOI] [Google Scholar]
  12. Beaugeard V. Muller J. Graillot A. Ding X. Robin J.-J. Monge S. Acidic polymeric sorbents for the removal of metallic pollution in water: A review. React. Funct. Polym. 2020;152:104599. doi: 10.1016/j.reactfunctpolym.2020.104599. [DOI] [Google Scholar]
  13. Geerlings M. W. Kaspersen F. M. Apostolidis C. Der Hout R. V. The feasibility of 225Ac as a source of α-particles in radioimmunotherapy. Nucl. Med. Commun. 1993;14:121–125. doi: 10.1097/00006231-199302000-00009. [DOI] [PubMed] [Google Scholar]
  14. Morgenstern A. Bruchertseifer F. Apostolidis C. Bismuth-213 and Actinium-225 – Generator Performance and Evolving Therapeutic Applications of Two Generator-Derived Alpha-Emitting Radioisotopes. Curr. Rad. 2012;5:221–227. doi: 10.2174/1874471011205030221. [DOI] [PubMed] [Google Scholar]
  15. Zhu H. Heinitz S. Eyley S. Thielemans W. Derveaux E. Adriaensens P. Binnemans K. Mullens S. Cardinaels T. Gamma radiation effects on AG MP-50 cation exchange resin and sulfonated activated carbon for bismuth-213 separation. RSC Adv. 2023;13:30990–31001. doi: 10.1039/D3RA06130B. [DOI] [PMC free article] [PubMed] [Google Scholar]
  16. Apostolidis C., Brandalise B., Carlos-Marquez R., Janssens W., Molinet R. and Nikula T., Method of loading a radioelement generator with mother radionuclide, US Pat., US2005/0008553, 2005
  17. Arrigo L. M. Jiang J. Finch Z. S. Bowen J. M. Beck C. L. Friese J. I. Greenwood L. R. Seiner B. N. Development of a separation method for rare earth elements using LN resin. J. Radioanal. Nucl. Chem. 2020;327:457–463. doi: 10.1007/s10967-020-07488-9. [DOI] [Google Scholar]
  18. Smith C. D. Dietz M. L. Support loading effects on the performance of an extraction chromatographic resin: Toward improved separation of trivalent lanthanides. Talanta. 2021;222:121541. doi: 10.1016/j.talanta.2020.121541. [DOI] [PubMed] [Google Scholar]
  19. Huang X. Dong J. Wang L. Feng Z. Xue Q. Meng X. Selective recovery of rare earth elements from ion-adsorption rare earth element ores by stepwise extraction with HEH(EHP) and HDEHP. Green Chem. 2017;19:1345–1352. doi: 10.1039/C6GC03388A. [DOI] [Google Scholar]
  20. Kumar S. S. Rao A. Yadav K. K. Lenka R. K. Singh D. K. Tomar B. S. Selective removal of Am(III) and Pu(IV) from analytical waste solutions of quality control operations using extractant encapsulated polymeric beads. J. Radioanal. Nucl. Chem. 2020;324:375–384. doi: 10.1007/s10967-020-07045-4. [DOI] [Google Scholar]
  21. Horwitz E. P. Chiarizia R. Dietz M. L. DIPEX: A new extraction chromatographic material for the separation and preconcentration of actinides from aqueous solution. React. Funct. Polym. 1997;33:25–36. doi: 10.1016/S1381-5148(97)00013-8. [DOI] [Google Scholar]
  22. Wang W. Cheng C. Y. Separation and purification of scandium by solvent extraction and related technologies: a review. J. Chem. Technol. Biotechnol. 2011;86:1237–1246. doi: 10.1002/jctb.2655. [DOI] [Google Scholar]
  23. Pillay K. K. S. A review of the radiation stability of ion exchange materials. J. Radioanal. Nucl. Chem. 1986;102:247–268. doi: 10.1007/BF02037966. [DOI] [Google Scholar]
  24. Chen M. Li Z. Geng Y. Zhao H. He S. Li Q. Zhang L. Adsorption behavior of thorium on N,N,N′,N′-tetraoctyldiglycolamide (TODGA) impregnated graphene aerogel. Talanta. 2018;181:311–317. doi: 10.1016/j.talanta.2018.01.020. [DOI] [PubMed] [Google Scholar]
  25. Kawamura T. Wu H. Kim S.-Y. Adsorption and separation behavior of strontium and yttrium using a silica-based bis(2-ethylhexyl) hydrogen phosphate adsorbent. J. Radioanal. Nucl. Chem. 2021;329:1001–1009. doi: 10.1007/s10967-021-07806-9. [DOI] [Google Scholar]
  26. Shu Q. Khayambashi A. Wang X. Wang X. Feng L. Wei Y. Effects of γ irradiation on bis(2-ethylhexyl)phosphoric acid supported by macroporous silica-based polymeric resins. Radiochim. Acta. 2018;106:249–258. doi: 10.1515/ract-2017-2758. [DOI] [Google Scholar]
  27. Ostapenko V. Vasiliev A. Lapshina E. Ermolaev S. Aliev R. Totskiy Y. Zhuikov B. Kalmykov S. Extraction chromatographic behavior of actinium and REE on DGA, Ln and TRU resins in nitric acid solutions. J. Radioanal. Nucl. Chem. 2015;306:707–711. doi: 10.1007/s10967-015-4331-y. [DOI] [Google Scholar]
  28. Belkhouche N.-E. Benyahia N. Modeling of Adsorption of Bi(III) from Nitrate Medium by Impregnated Resin D2EHPA/XAD-1180. J. Surf. Eng. Mater. Adv. Technol. 2011;01:30–34. [Google Scholar]
  29. Wu C. Brechbiel M. W. Gansow O. A. An Improved Generator for the Production of 213Bi from 225Ac. Radiochim. Acta. 1997;79:141–144. doi: 10.1524/ract.1997.79.2.141. [DOI] [Google Scholar]
  30. Yantasee W. Fryxell G. E. Pattamakomsan K. Sangvanich T. Wiacek R. J. Busche B. Addleman R. S. Timchalk C. Ngamcherdtrakul W. Siriwon N. Selective capture of radionuclides (U, Pu, Th, Am and Co) using functional nanoporous sorbents. J. Hazard. Mater. 2019;366:677–683. doi: 10.1016/j.jhazmat.2018.12.043. [DOI] [PMC free article] [PubMed] [Google Scholar]
  31. Abbasi W. A. Streat M. Sorption of uranium from nitric acid solution using TBP-impregnated activated carbons. Solvent Extr. Ion Exch. 1998;16:1303–1320. doi: 10.1080/07360299808934581. [DOI] [Google Scholar]
  32. Horwitz E. P. Bloomquist C. A. A. Chemical separations for super-heavy element searches in irradiated uranium targets. J. Inorg. Nucl. Chem. 1975;37:425–434. doi: 10.1016/0022-1902(75)80350-2. [DOI] [Google Scholar]
  33. Ondrák L. Ondrák Fialová K. Sakmár M. Vlk M. Bruchertseifer F. Morgenstern A. Kozempel J. Development of 225Ac/213Bi generator based on α-ZrP-PAN composite for targeted alpha therapy. Nucl. Med. Biol. 2024;132–133:108909. doi: 10.1016/j.nucmedbio.2024.108909. [DOI] [PubMed] [Google Scholar]
  34. Zhu H. Heinitz S. Eyley S. Thielemans W. Binnemans K. Mullens S. Cardinaels T. Sorption and desorption performance of La3+/Bi3+ by surface-modified activated carbon for potential application in medical 225Ac/213Bi generators. Chem. Eng. J. 2023;464:142456. doi: 10.1016/j.cej.2023.142456. [DOI] [Google Scholar]
  35. Monroy-Guzman F. De la Cruz Barba C. d. C. Jaime Salinas E. Garibay-Feblés V. Nava Entzana T. N. Extraction Chromatography Materials Prepared with HDEHP on Different Inorganic Supports for the Separation of Gadolinium and Terbium. Metals. 2020;10:1390. doi: 10.3390/met10101390. [DOI] [Google Scholar]
  36. El-Sofany E. A. Zaher W. F. Aly H. F. Sorption potential of impregnated charcoal for removal of heavy metals from phosphoric acid. J. Hazard. Mater. 2009;165:623–629. doi: 10.1016/j.jhazmat.2008.10.037. [DOI] [PubMed] [Google Scholar]
  37. Heidarinejad Z. Dehghani M. H. Heidari M. Javedan G. Ali I. Sillanpää M. Methods for preparation and activation of activated carbon: a review. Environ. Chem. Lett. 2020;18:393–415. doi: 10.1007/s10311-019-00955-0. [DOI] [Google Scholar]
  38. Ichou A. A. Benhiti R. Abali M. Dabagh A. Carja G. Soudani A. Chiban M. Zerbet M. Sinan F. Characterization and sorption study of Zn2[FeAl]-CO3 layered double hydroxide for Cu(II) and Pb(II) removal. J. Solid State Chem. 2023;320:123869. doi: 10.1016/j.jssc.2023.123869. [DOI] [Google Scholar]
  39. Lagergren S. K. About the Theory of So-called Adsorption of Soluble Substances, Kungliga Svenska Vetenskapsakademiens. Handlinger. 1898;24:1–19. [Google Scholar]
  40. Blanchard G. Maunaye M. Martin G. Removal of heavy metals from waters by means of natural zeolites. Water Res. 1984;18:1501–1507. doi: 10.1016/0043-1354(84)90124-6. [DOI] [Google Scholar]
  41. Tran H. N. You S.-J. Hosseini-Bandegharaei A. Chao H.-P. Mistakes and inconsistencies regarding adsorption of contaminants from aqueous solutions: A critical review. Water Res. 2017;120:88–116. doi: 10.1016/j.watres.2017.04.014. [DOI] [PubMed] [Google Scholar]
  42. Langmuir I. The adsorption of gases on plane surfaces of glass, mica and platinum. J. Am. Chem. Soc. 1918;40:1361–1403. doi: 10.1021/ja02242a004. [DOI] [Google Scholar]
  43. Freundlich H. Über die Adsorption in Lösungen. Z. Phys. Chem. 1907;57U:385–470. doi: 10.1515/zpch-1907-5723. [DOI] [Google Scholar]
  44. choi Y. Kim Y. Kang K. Y. Lee J. S. A composite electrolyte membrane containing high-content sulfonated carbon spheres for proton exchange membrane fuel cells. Carbon. 2011;49:1367–1373. doi: 10.1016/j.carbon.2010.11.056. [DOI] [Google Scholar]
  45. Okamura M. Takagaki A. Toda M. Kondo J. N. Domen K. Tatsumi T. Hara M. Hayashi S. Acid-Catalyzed Reactions on Flexible Polycyclic Aromatic Carbon in Amorphous Carbon. Chem. Mater. 2006;18:3039–3045. doi: 10.1021/cm0605623. [DOI] [Google Scholar]
  46. Lumetta G. J. Sinkov S. I. Krause J. A. Sweet L. E. Neodymium(III) Complexes of Dialkylphosphoric and Dialkylphosphonic Acids Relevant to Liquid-Liquid Extraction Systems. Inorg. Chem. 2016;55:1633–1641. doi: 10.1021/acs.inorgchem.5b02524. [DOI] [PubMed] [Google Scholar]
  47. Shu Q. Khayambashi A. Wang X. Wei Y. Studies on adsorption of rare earth elements from nitric acid solution with macroporous silica-based bis(2-ethylhexyl)phosphoric acid impregnated polymeric adsorbent. Adsorpt. Sci. Technol. 2018;36:1049–1065. doi: 10.1177/0263617417748112. [DOI] [Google Scholar]
  48. Chen J.-H. Chen W.-R. Gau Y.-Y. Lin C.-H. The preparation of di(2-ethylhexyl) phosphoric acid modified Amberlite 200 and its application in the separation of metal ions from sulfuric acid solution. React. Funct. Polym. 2003;56:175–188. doi: 10.1016/S1381-5148(03)00056-7. [DOI] [Google Scholar]
  49. Smith C. D. Foersterling F. H. Dietz M. L. Solvent structural effects on the solubility of bis(2-ethylhexyl)phosphoric acid (HDEHP) in room-temperature ionic liquids. Separ. Sci. Technol. 2020;56:800–810. doi: 10.1080/01496395.2020.1728322. [DOI] [Google Scholar]
  50. Wang W. Park R. Y. Meyer D. H. Travesset A. Vaknin D. Ionic specificity in pH regulated charged interfaces: Fe3+versus La3+ Langmuir. 2011;27:11917–11924. doi: 10.1021/la201880g. [DOI] [PubMed] [Google Scholar]
  51. Egorova B. V. Oshchepkov M. S. Fedorov Y. V. Fedorova O. A. Budylin G. S. Shirshin E. A. Kalmykov S. N. Complexation of Bi3+, Ac3+, Y3+, Lu3+, La3+ and Eu3+ with benzo-diaza-crown ether with carboxylic pendant arms. Radiochim. Acta. 2016;104:555–565. doi: 10.1515/ract-2015-2560. [DOI] [Google Scholar]
  52. Depuydt D. Van den Bossche A. Dehaen W. Binnemans K. Halogen-free synthesis of symmetrical 1,3-dialkylimidazolium ionic liquids using non-enolisable starting materials. RSC Adv. 2016;6:8848–8859. doi: 10.1039/C5RA22798D. [DOI] [Google Scholar]
  53. Coday B. D. Luxbacher T. Childress A. E. Almaraz N. Xu P. Cath T. Y. Indirect determination of zeta potential at high ionic strength: Specific application to semipermeable polymeric membranes. J. Membr. Sci. 2015;478:58–64. doi: 10.1016/j.memsci.2014.12.047. [DOI] [Google Scholar]
  54. Spivakov B. Y. Stoyanov E. S. Gribov L. A. Zolotov Y. A. Raman laser spectroscopic studies of bismuth(III) halide complexes in aqueous solutions. J. Inorg. Nucl. Chem. 1979;41:453–455. doi: 10.1016/0022-1902(79)80423-6. [DOI] [Google Scholar]
  55. Horváth O. Mikó I. Spectra, equilibrium and photoredox chemistry of iodobismuthate(III) complexes in acetonitrile. Inorg. Chim. Acta. 2000;304:210–218. doi: 10.1016/S0020-1693(00)00090-6. [DOI] [Google Scholar]
  56. Babu C. M. Binnemans K. Roosen J. Ethylenediaminetriacetic Acid-Functionalized Activated Carbon for the Adsorption of Rare Earths from Aqueous Solutions. Ind. Eng. Chem. Res. 2018;57:1487–1497. doi: 10.1021/acs.iecr.7b04274. [DOI] [Google Scholar]
  57. Thiele N. A. Wilson J. J. Actinium-225 for Targeted alpha Therapy: Coordination Chemistry and Current Chelation Approaches. Cancer Biother. Rad. 2018;33:336–348. doi: 10.1089/cbr.2018.2494. [DOI] [PMC free article] [PubMed] [Google Scholar]
  58. Pearson R. G. Absolute electronegativity and hardness: application to inorganic chemistry. Inorg. Chem. 1988;27:734–740. doi: 10.1021/ic00277a030. [DOI] [Google Scholar]
  59. Parr R. G. Pearson R. G. Absolute hardness: companion parameter to absolute electronegativity. J. Am. Chem. Soc. 1983;105:7512–7516. doi: 10.1021/ja00364a005. [DOI] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

RA-014-D4RA06276K-s001

Data Availability Statement

The data supporting this article have been included as part of the ESI.


Articles from RSC Advances are provided here courtesy of Royal Society of Chemistry

RESOURCES