Abstract
The potential of the island of La Palma (Canary Islands) to host geothermal resources is very high, mainly due to its high volcanic activity. The primary goal of this study is to get a tridimensional image of the seismic intrinsic attenuation using ambient seismic noise and to identify anomalies that may be linked to active geothermal reservoirs on La Palma island. For this purpose, we developed a new Ambient Noise Attenuation Tomography (ANAT) technique, which uses seismic ambient noise for imaging intrinsic attenuation in 3-D at a local scale down to 5 km depth. Our research identifies two areas with high attenuation in the island’s southern region. One area could be associated with hydrothermal alteration zones beneath the Cumbre Vieja volcanic complex. Another high-attenuation zone was observed in the island’s southern part, which could be associated with extensively fractured rocks that might facilitate the circulation of heated fluids. Furthermore, we discuss the geothermal relevance of such anomalies, making a comparison with previous resistivity, S-wave velocity and density models. This study confirms that intrinsic attenuation retrieved from the coda of Rayleigh waves is more sensitive to the presence of fluids than velocity. Fluids being a key component of active geothermal reservoirs, it is reasonable to expect intrinsic attenuation anomalies in these systems. Therefore, we conclude that ANAT can be useful for geothermal exploration.
Subject terms: Geophysics, Seismology, Volcanology
Introduction
Elastic waves experience energy loss as they travel through a medium, resulting in a reduction in amplitude as they move away from the source. This decrease in amplitude can be attributed to two factors: either the geometrical spreading of the wavefront or the scattering and intrinsic attenuation of elastic energy, which converts it into different forms such as heat. Various mechanisms can produce intrinsic attenuation, such as frictional dissipation1, fluid flow in the pore space2, or squirting mechanism and local scale fluid motion3. For this reason, the characterization of seismic attenuation is useful for studying the structure of volcanoes (e.g4.,) and hydrothermal systems (e.g5.,). One of the ways to measure the attenuation is through the coda quality factor , which can be determined by measuring the decay of seismic energy with time6. Calvet et al7. demonstrated that in the later stages of the seismic coda, the dependency of on anisotropy and scattering attenuation diminishes notably. As a result, in this scenario can be considered as a direct assessment of intrinsic attenuation ( ).
Seismic attenuation plays an important role in geophysical exploration. Specifically, seismic attenuation tomography is a dependable and valuable tool for imaging the Earth’s internal structure. Many case studies have highlighted the usefulness of seismic attenuation tomography using earthquakes. Hence, Martínez-Arevalo et al4. and Castro-Melgar et al8. observed a high-consolidated body in the central structure of the Etna volcano that modifies the path of the ascent of new magma. Also, Del Pezzo et al5. and De Siena et al9. used earthquake-based attenuation tomography to study the Vesuvius and Campi Flegrei, revealing high-attenuation anomalies related to hydrothermal systems and partial melt materials. Furthermore, Calvet et al7. used the to observe spatial variations of seismic attenuation in the Pyrenees. In general, applying seismic attenuation tomography is useful for revealing the presence of magmatic and hydrothermal fluids10–16. Seismic attenuation tomography can also be achieved by using active seismic sources. This kind of study was applied to different volcanoes, revealing attenuation anomalies related to the carbonate basement of the Merapi volcano17or a cracked medium and historical volcanic activity in Vesuvius and Tenerife volcanoes5,18–22.
Recently, several researchers have highlighted the possibility of extracting seismic attenuation through interferometric measurements of surface-wave Empirical Green’s Functions (EGFs)23. Weemstra et al24. noted that the relationship between quality factor and frequency indicates a depth-dependent variation in attenuation, correlating with the geological characteristics of the surveyed area. Using numerical approaches, other studies demonstrated that the intrinsic attenuation can be successfully retrieved from the EGF25–28. The extraction of attenuation from EGFs was used for Ambient Noise Attenuation Tomography (ANAT) in regional-scale seismic networks (approximately 100-1000 km)23,29,30. Prieto et al29. demonstrated how 1-D depth profiles of phase velocity and quality factor can be effectively derived from stacked cross-correlations of ambient noise. This approach was extended to the 3-D velocity/quality factor case by Lawrence and Prieto30, who reconstructed phase velocity and attenuation coefficient maps at periods of 8-32 s for the western United States. Lin et al23. employed a different approach, assessing the amplitude decay of time-domain cross-correlations. Furthermore, Liu et al31. studied the Los Angeles Basin structure using ambient seismic noise interferometry to infer the near-surface attenuation structure. In addition, Borleanu et al32. obtained 2-D intrinsic attenuation maps at different frequencies of the Eastern-Europe region, revealing heterogeneous structures within the upper crustal sedimentary layer that they related to fluids and high-temperature anomalies of water-content mineralogy. Note that all these studies were focused on regional scales (covering areas larger than 4000 approximately).
In this study, we conducted the first-ever 3-D intrinsic attenuation tomography at a local scale using seismic ambient noise. Indeed, in previous works dealing with attenuation imaging, 3-D models were obtained using active or passive seismic sources10–16,22, while noise-based studies were limited to 2-D maps at a regional scale30–32. Our research is dedicated to unravelling the geological structure of La Palma island (700 , Fig. 1) through a novel ANAT method, specifically identifying intrinsic attenuation anomalies that could be linked to geothermal reservoirs. To enrich our comprehension, we compared the 3-D intrinsic attenuation model with previous resistivity33, S-wave velocity34, and density models35,36.
Fig. 1.
Geological map of La Palma island (adapted from Padrón et al55.). The white star on the map denotes the site of the Tajogaite eruption, the most recent volcanic event that occurred on the island from September 19th to December 13th, 2021. Triangles on the map indicate the positions of both temporary and permanent seismic stations, with their colors indicating distinct phases as detailed in the caption. The digital elevation model and historical lava flow data were obtained from GRAFCAN’s public graphic repository (www.grafcan.es ). The 2021 lava flow data was sourced from the Copernicus Emergency Management Service, operated by the European agency (https://emergency.copernicus.eu/mapping/list-of-components/EMSR546). The figure was created using QGIS 3.22 software (https://www.qgis.org).
Geological context
La Palma island, covering an area of , is located in the north-westernmost part of the Canary Islands archipelago. The geological structure of La Palma is composed of two main units: the central Taburiente Domain in the north, which dates from 2.0 to 0.51 million years ago, and the southern Dorsal Domain, which has been active from 0.81 million years ago to the present day37.
The island’s formation began 4 My ago with the emissions of submarine lava. Then, 1.77 My ago, the first subaerial material was emitted, forming the Taburiente stratovolcano. After the formation of the Taburiente stratovolcano (between 0.77 and 0.56 My), another volcanic complex, named Cumbre Nueva, was formed in the central part of the island. During the formation process of this volcanic edifice, the western part of the edifice suffered a landslide, creating a large Aridane valley in the central part of the island. Then, within this valley, the Bejenado stratovolcano was formed between 0.56 and 0.49 My. Finally, 0.12 Years ago, the Cumbre Vieja volcanic complex started its formation and gave rise to a complex volcanic rift that stretches 20 km along and rises 1950 m high along an N-S direction. This volcanic system covers an area of and it is characterized by multiple cinder cones and cracks formed during volcanic activity aligned in a N-S direction. This area currently represents the most volcanic active part of the island, where all historical eruptions took place.
The most recent volcanic eruption on La Palma island, the Tajogaite eruption, started on September 19th, 2021 and persisted until December 13th (Tajogaite eruption). The Tajogaite eruption was preceded in 2017 by low-magnitude but relatively deep seismic activity (25-35 km)38. One week before the eruption began, a notable seismic unrest and ground deformation started on September 11th, 202138,39. The seismicity and deformation indicated an upward dike intrusion process39. On September 19th, at 14:00 UTC, there started a fissural eruption that involved mainly strombolian activity and occasional phreatomagmatic pulses. These phreatomagmatic pulses emitted an intense eruptive column, reaching a maximum height of 8.500 m40. This last eruption served as a reminder of the island’s potential to harbour geothermal resources.
Methods
The methodology we employed for Ambient Noise Attenuation Tomography consists of several key steps. First, is measured using the lapse-time dependence method7, which involves assessing as a function of the coda window length () for different onset times of the coda (). Second, a 2-D spatial attenuation inversion is performed using a linear inversion scheme with specific sensitivity kernels considering diffusion as the dominant scattering regime9. Finally, a 1-D depth inversion is conducted utilizing a linear inversion scheme and sensitivity kernels of the Rayleigh wave fundamental mode extracted from an existing S-wave velocity model34. Detailed information on these steps are described in the following paragraphs.
Data acquisition
Between June and August 2018, we installed 23 seismic stations in the southern part of the island during two phases of one month, specifically focusing on investigating the Cumbre Vieja volcanic complex. In July 2020, we deployed 15 stations distributed throughout the whole island during two months. The primary objective of this expansion was to characterize areas not previously sampled during the initial 2018 campaigns. Furthermore, our temporary campaigns were supplemented by utilizing six permanent stations operated by the Instituto Volcanológico de Canarias (INVOLCAN) for volcano monitoring (Fig. 1).
Since both temporary networks were deployed in summer, there are no significant seasonal effects. Furthermore, we believe that there are no potential temporal variations in the attenuation that could influence the overall attenuation pattern. Previous studies on seismic attenuation tomography, such as those by Prudencio et al14., utilized datasets spanning several years (between 1984 and 2014). Therefore, we consider the assumption of largely time-invariant attenuation to be reasonable.
Based on the distribution of the seismic stations, the Cumbre Vieja volcano (see Fig. S1 in the supplementary materials) has the greatest concentration of stations and anisotropy in ray paths. This area is the most active part of the island in terms of volcanic activity and the most interesting from a geothermal exploration point of view.
Intrinsic attenuation measurement from ambient noise ()
To extract the from the Empirical Green’s Function (EGF), we used the results obtained by Cabrera-Pérez et al34.. Seismic ambient noise data were pre-processed to obtain the Empirical Green’s functions (EGFs). Initially, in order to identify and remove time windows containing earthquake signals, we applied an automated network-based method. The method relies on analyzing the network covariance matrix, in which the width of the eigenvalues distribution (referred to as spectral width) serves as an indicator of the number of seismic sources composing the wavefield41. Applying this analysis to each five-minute time window of our data automatically determines whether a coherent signal, such as an earthquake, is present within that specific time window.
Subsequently, we applied a bandpass filter in the frequency range 0.01-5.00 Hz. Then, we employed a standard ambient noise pre-processing including temporal one-bit normalization and spectral whitening42to enhance data quality and reduce non-stationarity in the remaining data. Cupillard et al43. demonstrated theoretically that temporal and spectral normalization methods, like one-bit normalization and spectral whitening, do not affect the relative decay of amplitude when noise sources are evenly distributed. This was also demonstrated by Lin et al23. in a practical case.
Following these pre-processing steps, we computed cross-correlations for all station pairs using five-minute-long windows and stacked them over one month for the 2018 campaigns and two months for the 2020 campaign. The utilization of a short time window (five minutes instead of one day) for cross-correlation provides more precise information regarding the amplitude of EGFs29. Specifically, we focused on the vertical-vertical components of 578 station pairs. The resulting cross-correlations are presented in Figure 2.A, revealing the presence of coherent wavetrains of dispersive Rayleigh waves.
Fig. 2.
Noise-based dataset used for intrinsic attenuation measurement. (A) Empirical Green’s functions sorted according to the distance between stations. The blue solid and dashed lines represent velocities of 1.0 and 3.0 km/s, respectively. (B) and (C) represent the measured values of with respect to the frequency (mean and standard deviation marked by red points and blue lines, respectively) and interstation distance, respectively.
For each EGF, we determined the for different central frequencies between 0.3 Hz and 3.3 Hz (Fig. 2.B). We used this frequency range because it is the same that Cabrera-Pérez et al34. used for the 2-D inversion of group velocity maps in this region. They selected this frequency range using a criterion of at least 50 measurements of group velocity for the tomographic inversion. The was measured using the lapse-time dependence method7, considering a range of values for both the length of the coda window () and the onset time of the coda (). As suggested by Calvet and Margerin7, to ensure that the measured represents the physically meaningful intrinsic quality factor (), we need to consider the variation of as a function of for different (named function) and to extract its mean value in the range when the function stabilizes at sufficiently large values (Fig. S2.B in the supplementary materials). This also ensures that the estimate of is not hampered by transient phenomena like earthquakes7. We applied a positive exponent of 2 to parameterize the coda decay, based on the recommendation by Calvet and Margerin7. Nonetheless, the influence of the value has only a minor impact on the estimation of 7. We employed a window-sliding algorithm44 to automatically determine the EGF coda and the function’s stabilised segment, facilitating the automated measurement of values (Fig. S3 in the supplementary materials). As shown in Figure 2.B, the mean value of the observed decreases as the frequency increases, consistently with findings from previous studies45,46. Figure 2.C displays measurements as a function of the distance between stations, for all the possible station pairs. Notably, no discernible correlation emerges between values and the interstation distance, suggesting that the intrinsic attenuation is not governed by dispersion effects.
2-D intrinsic attenuation maps
The 2-D spatial attenuation inversion at a given frequency is achieved through linear inversion with heuristic sensitivity kernels assuming diffusion as the dominant scattering regime47. The analytical expression of these sensitivity kernels governing the propagation of scattered waves between each station pair, is given as follows47:
| 1 |
where () and () represent the coordinates of the (virtual) sources and receivers, represents the spatial aperture of the weighting function, and D represents the source-receiver distance. Following previous studies, a value of 0.2 was selected for the parameter 47. An example of a sensitivity kernel corresponding to a specific station pair can be seen in Figure S4 in the supplementary materials. Del Pezzo and Ibáñez47 previously used these kernels for imaging the spatial distribution of the intrinsic attenuation parameter , while Cabrera-Pérez et al48. used the same kernels to map relative velocity variations during the pre-eruptive phase of the 2021 La Palma eruption.
With these sensitivity kernels, the forward model relating the observed attenuation at a given frequency for a given station pair to the 2-D model of attenuation , can be expressed as:
| 2 |
where, n represents a normalization factor:
| 3 |
The forward model (2) is discretized on a 29 48 km mesh with regular tiles of size 0.6 1.0 km49. The linear inversion is performed using a damped least squares approach. The L-curve criterion was used to select the proper damping parameter.
We performed different checkerboard and spike tests to determine the spatial resolution of the tomographic images. We used three different checkerboard sizes of , and , corresponding approimately to sizes of 5.5 km 5.5 km, 8.8 km 8.8 km and 11.1 km 11.1 km, respectively. Furthermore, we used different spike sizes with diameters of 7 km, 4 km and 2 km. Maximum and minimum values of 0.02 and 0.01 were used for in the checkerboard tests (Fig. S5 and S6 in the supplementary materials). The model with a resolution of and 7 km of diameter were correctly retrieved in the whole island (Figs. S5.A-B and S6.A-B). Conversely, the checkerboard tests with a resolution of and as well as the spike tests with a diameter of 4 km and 2 km were not correctly retrieved in the island’s northern part (Figs. S5.C-F and S6.C-F), due to a lower ray path density in this zone (see Fig. S1 in the supplementary materials). However, the models were correctly retrieved in the southern part of the island (Figs. S5.C-F and S6.C-F), where the ray path density is higher, which is the main zone of interest of the study.
Depth inversion for 1-D intrinsic attenuation profiles
The last step in the 3-D attenuation imaging process involves inverting the 2-D attenuation maps to obtain 1-D attenuation profiles at depth. First, a value is extracted in 347 points of each 2-D attenuation map associated with a specific frequency. These points correspond to those where 1-D S-wave velocity models were obtained by ambient noise tomography by Cabrera-Pérez et al34.. Second, we calculated the depth sensitivity kernel at each frequency for each 1-D velocity model (), covering a frequency range between 0.3 Hz and 3.3 Hz. The depth sensitivity kernels were calculated using the disba software50. This software is a computationally efficient Python library for modeling surface wave dispersion, enabling the calculation of forward modeling (to compute Rayleigh and Love waves phase or group dispersion curves) and the computation of Rayleigh-wave ellipticity sensitivity kernels with respect to layer thickness, P- and S-wave velocities, and density. With these depth sensitivity kernels, the forward problem relating the observed attenuation values at distinct frequencies to the 1-D model of attenuation at depth , can be expressed as:
| 4 |
where f denotes the central frequency used for calculating the depth sensitivity kernels . The resulting discrete inverse linear problem is solved using damped least squares. Figure S7 in the supplementary materials shows an example of depth sensitivity kernels at different frequencies for a specific 1-D velocity model obtained by ambient noise tomography34 (Fig. S7.A), together with the retrieved 1-D attenuation profile at depth (Fig. S7.B).
To assess the depth resolution of our intrinsic attenuation model, we conducted a 3D checkerboard test with dimensions of approximately in width, height and depth, respectively. This test involved maximum attenuation values of 0.02 and minimum one of 0.01. By following the method previously described, we utilized 347 control points to reconstruct the 3D checkerboard pattern. Figures 4 and 5 show the horizontal and vertical cross-sections of the resulting 3D resolution test. Our model generally achieves a resolution down to a depth of 2 km across most of the study area, effectively resolving attenuation values and the checkerboard pattern (Fig. 5). Furthermore, between 2 km and 3 km depth, we can retrieve the geometry of the checkerboard pattern but not the attenuation values. Below a depth of 3 km, our model lacks sensitivity. For this reason, we determine that the maximum resolution in depth is up to 2 km, although we can still have some sensitivity down to 3 km.
Fig. 4.
Horizontal cross-section of the 3D checkerboard test with dimensions of approximately 9 km 9 km 1.5 km in width, height and depth, respectively. The synthetic maps at different depths are shown in panels (A), (C), (E), (G) and (I). The corresponding recovered Qc-1 maps at different depths are shown in panels (B), (D), (F), (H) and (J), respectively. The digital elevation model was sourced from GRAFCAN’s repository (www.grafcan.es), and the figure was generated using the Matplotlib Python package57.
Fig. 5.
Vertical cross-sections (cf. A-A’ and B-B’ in Fig. 4.B) of the 3-D synthetic (left panel) and retrieved (right panel) model.
Results and discussion
Figure 3 shows six 2-D maps of obtained for frequencies between 0.3 Hz and 3.3 Hz. The mean value of decreases with frequency, from 0.039 to 0.012, consistently with the global trend of the average curve shown in Figure 2.B. Some important attenuation contrasts appear across the island, which evolve with the frequency. The image shows a high attenuation zone in the southern part of the island, mainly at low frequencies corresponding to deeper penetration depths (Figs. 3A-C). This high attenuation anomaly decreases significantly at frequencies higher than 1.50 Hz, except in the two flanks of the Cumbre Vieja volcanic complex at 3.30 Hz corresponding to superficial layers (Fig. 3F). Frequencies between 2.10 Hz and 2.70 Hz show the lowest attenuation levels in the whole island, with values down to 0.012 (Figs. 3D-E). Conversely, the northern part of the island shows low levels of attenuation in general.
Fig. 3.

Retrieved 2-D maps of at different frequencies (indicated at the top-right of each panel). Black triangles represent the seismic stations. The digital elevation model was obtained from GRAFCAN’s repository (www.grafcan.es). The figure was created using the Matplotlib Python package57.
Figure 6 shows four horizontal cross-sections of the 3-D model of at different depths. The main anomalies observed in the model are marked as high (H) attenuation zones in Fig. 6B and C. It appears that the island shows a very strong heterogeneity in the attenuation distribution, with the principal anomalies located in the southern part of the island. Figure 7 shows three vertical cross-sections of the 3-D model of , whose positions are indicated in Fig. 6A. A high-attenuation zone (H1) extends from the surface to 2000 m b.s.l. (below sea level) in the island’s southern part, with values reaching 0.20 (Fig. 7A and C). Another high-attenuation zone (H2) is present between 0 m b.s.l. and 2000 m b.s.l. in the eastern part of the Cumbre Vieja volcanic complex (Fig. 7B and C). The last high-attenuation zone (H3) is located in the island’s southernmost tip, at depths above 2000 m b.s.l. (Fig. 7A and B).
Fig. 6.
Retrieved 2-D maps of at different depths (indicated at the top-right of each panel). The white and black dots in panels B and C represent high (> 316 ) and low (< 3.16 ) resistivity zones33, respectively. The white lines in panels A, B and C represent low-density (-200 ) anomalies36. The digital elevation model was sourced from GRAFCAN’s public graphic repository (www.grafcan.es), and the figure was produced using QGIS 3.22 software (https://www.qgis.org).
Fig. 7.
Vertical cross-sections (cf. A-A’, B-B’ and C-C’ in Fig. 6.A) of the 3-D model of . The horizontal black dashed line represents the depth at which the model resolution is maximum and below which it starts to decrease. White and red triangles represent the historical and Tajogaite eruption sites, respectively. The white dashed contour represents the hydrothermal zone imaged in the S-wave velocity model obtained by ambient noise tomography by Cabrera-Pérez et al34.
The 3-D model of La Palma island exposed in Figs. 6 and 7provides a detailed view of some upper crustal geological structures, revealing three main attenuation anomalies within the Cumbre Vieja volcanic complex in the southern part of the island. In the following, we discuss the volcanological and geothermal relevance of such anomalies, comparing them with the resistivity model of Di Paolo et al33., the density models of Camacho et al35. and Montesinos et al36., and the S-wave velocity models of Cabrera-Pérez et al34. (ambient noise tomography) or D’Auria et al38. and Serrano et al52. (local earthquake tomography). Table S1 in the supplementary material is a summary table comparing the intrinsic attenuation model with other geophysical models.
From a geothermal point of view, the most noteworthy features are the high-attenuation anomalies H1 and H2 (Figs. 6 and 7). These anomalies align with low-resistivity zones, low S-wave velocity zones, and low-density areas, for which various studies have proposed different interpretations. Camacho et al35. associated these low-density anomalies with shallow fractures following the N-S rift structure of Cumbre Vieja, while Montesinos et al36. interpreted them as highly fractured and altered structures related to an active hydrothermal system. Di Paolo et al33. suggested that these low-resistivity anomalies could be related to clay alteration caps (illite and illite-smectite). Similarly, Cabrera-Pérez et al34. attributed these low-velocity anomalies to a potential hydrothermal zone. Furthermore, D’Auria et al38. and Serrano et al52. observed low-velocity and high Vp/Vs values in the same areas, which they related to hydrothermal alteration ascribed to the activity of the geothermal system of the Cumbre Vieja volcanic complex.
Therefore, we believe these high-attenuation anomalies H1 and H2 could be associated with a hydrothermal alteration zone, possibly linked to an active or fossil hydrothermal system in the Cumbre Vieja volcanic complex. This hypothesis is supported by velocity variations (dv/v) observed by Cabrera-Pérez et al48., who indirectly confirmed the existence of a potential geothermal reservoir in this zone through ambient noise interferometry during the pre-eruptive phase of the Tajogaite eruption. Indeed, these authors observed a drop in dv/v values 9.5 days prior to the eruption, which they explained by the ascent of hydrothermal fluids towards the surface through this hydrothermal zone. On the other hand, Cabrera-Pérez et al34. noted that the hypocenters of the pre-eruptive seismicity of the Tajogaite eruption were significantly reduced in this low-velocity and high-attenuation zone. This could be a consequence of the presence of hydrothermally altered material characterized by a lower rigidity and/or a more ductile rheology. This latter observation corroborates similar findings by Del Pezzo et al9., who identified high attenuation structures associated with gas or fluid reservoirs beneath other volcanic regions.
Another high-attenuation anomaly, H3, is located in the southern part of the island (Figs. 6 and 7), below the historical eruptions of San Antonio (1677) and Teneguía (1971) volcanoes (Fig. 7A and B). Notably, this high attenuation zone does not correspond to any known resistivity or density anomaly reported in previous studies. Nevertheless, Cabrera-Pérez et al34. imaged a low-velocity zone in this area, which they associated with high-temperature rocks and a network of fractures through which hydrothermal fluids and gases ascend to the surface, particularly under the Teneguía and San Antonio volcanoes. This hypothesis aligns with the subsidence detected by InSAR beneath Teneguía volcano by Prieto et al53., which they attributed to a thermal source. Additionally, Padrón et al54. recorded diffuse emissions exceeding 800 and anomalous temperatures between and at a depth of 40 cm in the Teneguía volcano area before the Tajogaite eruption (2001–2013). Notably, a hot spring (Fuente Santa) in the southern part of La Palma island exhibits water temperatures reaching and elevated and levels exceeding 2000 mg/L55, suggesting underground water circulation through high-temperature rocks. As a result, the high-attenuation anomaly H3 may be associated with fracture zones allowing fluids to migrate to the surface, coinciding with the observed geochemical anomalies54,55, subsidence zone53, and low-velocity zone34.
Conclusion
Using ANAT, we obtained a 3-D intrinsic attenuation model of La Palma island. Analyzing data from 44 broadband seismic stations and determining values for 424 station pairs, we used a linear inversion with appropriate sensitivity kernels to generate 2-D maps of intrinsic attenuation at different frequencies. Subsequently, we used some specific depth sensitivity kernels to create 1-D depth profiles of intrinsic attenuation at 347 points of the 2-D maps. This last step allowed obtaining a full 3-D intrinsic attenuation model of the island of La Palma.
The 3-D model reveals three areas with significant attenuation, termed H1, H2, and H3. The high-attenuation anomalies H1 and H2 are interpreted as hydrothermal alteration zones associated with the presence of an active or fossil hydrothermal system in the Cumbre Vieja volcanic complex. The anomaly H3 is associated with fractured rocks favouring the ascent of hot fluids toward the surface in the island’s southern part. This hypothesis is also supported by geophysical and geochemical anomalies observed in previous studies34,53–55.
The novel passive seismic attenuation tomography method proposed in this work (named ANAT) was revealed to be highly appropriate for attenuation studies at a local scale in areas with low seismicity. This method does not require active sources and, for this reason, is convenient for various scientific and industrial applications. We maintain that its application, jointly with classical ambient noise tomography, provides an excellent tool for surface geothermal exploration and, in general, for imaging upper crustal structures.
Supplementary Information
Acknowledgements
The INVOLCAN team was supported by the project “Impulso a la energía geotérmica de alta entalpía en Canarias” (187G0132), financed by Gobierno de Canarias.
Data Availibility
All the Empirical Green’s Functions, intrinsic attenuation values, 2D intrinsic attenuation maps, and 1D depth intrinsic attenuation models obtained in this work are available in the Zenodo repository at Cabrera-Pérez et al56.
Footnotes
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
The online version contains supplementary material available at 10.1038/s41598-024-79076-w.
References
- 1.Tao, G., King, M. & Nabi-Bidhendi, M. Ultrasonic wave propagation in dry and brine-saturated sandstones as a function of effective stress: laboratory measurements and modelling 1. Geophysical Prospecting43(3), 299–327 (1995). [Google Scholar]
- 2.Biot, M. A. Theory of propagation of elastic waves in a fluid-saturated porous solid. ii. higher frequency range. The Journal of the acoustical Society of america28(2), 179–191 (1956). [Google Scholar]
- 3.Mavko, G. M. & Nur, A. Wave attenuation in partially saturated rocks. Geophysics44(2), 161–178 (1979). [Google Scholar]
- 4.Martínez-Arévalo, C., Patane, D., Rietbrock, A., & Ibánez, J.M. The intrusive process leading to the Mt. Etna 2001 flank eruption: Constraints from 3-D attenuation tomography, Geophysical Research Letters 32 (21) (2005).
- 5.Del Pezzo, E., Bianco, F., De Siena, L. & Zollo, A. Small scale shallow attenuation structure at Mt. Vesuvius, Italy, Physics of the Earth and Planetary Interiors157(3–4), 257–268 (2006). [Google Scholar]
- 6.Aki, K. & Chouet, B. Origin of coda waves: Source, attenuation, and scattering effects. Journal of Geophysical Research80(23), 3322–3342. 10.1029/jb080i023p03322 (1975). [Google Scholar]
- 7.Calvet, M. & Margerin, L. Lapse-Time Dependence of Coda Q: Anisotropic Multiple-Scattering Models and Application to the Pyrenees. Bulletin of the Seismological Society of America103(3), 1993–2010 (2013). [Google Scholar]
- 8.Castro-Melgar, I., Prudencio, J., Del Pezzo, E., Giampiccolo, E., & Ibanez, J.M. (2021). Shallow magma storage beneath Mt. Etna: Evidence from new attenuation tomography and existing velocity models, Journal of Geophysical Research: Solid Earth 126 (7), e2021JB022094.
- 9.De Siena, L., Del Pezzo, E., & Bianco, F. Seismic attenuation imaging of Campi Flegrei: Evidence of gas reservoirs, hydrothermal basins, and feeding systems, Journal of Geophysical Research: Solid Earth 115 (B9) (2010).
- 10.De Siena, L., Thomas, C., Waite, G. P., Moran, S. C. & Klemme, S. Attenuation and scattering tomography of the deep plumbing system of Mount St. Helens, Journal of Geophysical Research: Solid Earth119(11), 8223–8238 (2014). [Google Scholar]
- 11.De Siena, L. et al. Space-weighted seismic attenuation mapping of the aseismic source of Campi Flegrei 1983–1984 unrest. Geophysical Research Letters44(4), 1740–1748 (2017). [Google Scholar]
- 12.De Landro, G. et al. High resolution attenuation images from active seismic data: The case study of solfatara volcano (southern italy). Frontiers in Earth Science7, 295 (2019). [Google Scholar]
- 13.Di Martino, M. D. P., De Siena, L., Serlenga, V. & De Landro, G. Reconstructing hydrothermal fluid pathways and storage at the solfatara crater (campi flegrei, italy) using seismic scattering and absorption. Frontiers in Earth Science10, 852510 (2022). [Google Scholar]
- 14.Prudencio, J. & Manga, M. 3-D seismic attenuation structure of Long Valley caldera: looking for melt bodies in the shallow crust. Geophysical Journal International220(3), 1677–1686 (2020). [Google Scholar]
- 15.Sketsiou, P., De Siena, L., Gabrielli, S. & Napolitano, F. 3-D attenuation image of fluid storage and tectonic interactions across the Pollino fault network. Geophysical Journal International226(1), 536–547 (2021). [Google Scholar]
- 16.Talone, D., De Siena, L., Lavecchia, G., & de Nardis, R. The Attenuation and Scattering Signature of Fluid Reservoirs and Tectonic Interactions in the Central-Southern Apennines (Italy), Geophysical Research Letters 50 (22), e2023GL106074 (2023).
- 17.Wegler, U. & Lühr, B. G. Scattering behaviour at Merapi volcano (Java) revealed from an active seismic experiment. Geophysical Journal International145(3), 579–592 (2001). [Google Scholar]
- 18.Wegler, U. Analysis of multiple scattering at Vesuvius volcano. Italy, using data of the TomoVes active seismic experiment, Journal of volcanology and geothermal research128(1–3), 45–63 (2003). [Google Scholar]
- 19.Wegler, U. Diffusion of seismic waves in a thick layer: Theory and application to Vesuvius volcano, Journal of Geophysical Research: Solid Earth 109 (B7) (2004).
- 20.De Siena, L., Del Pezzo, E., Bianco, F. & Tramelli, A. Multiple resolution seismic attenuation imaging at Mt. Vesuvius, Physics of the Earth and Planetary Interiors173(1–2), 17–32 (2009). [Google Scholar]
- 21.Prudencio, J., Del Pezzo, E., García-Yeguas, A. & Ibáñez, J. M. Spatial distribution of intrinsic and scattering seismic attenuation in active volcanic islands-I: Model and the case of Tenerife Island. Geophysical Journal International195(3), 1942–1956. 10.1093/gji/ggt361 (2013). [Google Scholar]
- 22.Prudencio, J. et al. 3D attenuation tomography of the volcanic island of Tenerife (Canary Islands). Surveys in Geophysics36, 693–716 (2015). [Google Scholar]
- 23.Lin, F.-C., Ritzwoller, M.H., Shen, W. On the reliability of attenuation measurements from ambient noise cross-correlations, GEOPHYSICAL RESEARCH LETTERS, 38 (2011). 10.1029/2011GL047366.
- 24.Weemstra, C., Boschi, L., Goertz, A. & Artman, B. Seismic attenuation from recordings of ambient noise. Geophysics78(1), Q1–Q14 (2013). [Google Scholar]
- 25.Cupillard, P. & Capdeville, Y. On the amplitude of surface waves obtained by noise correlation and the capability to recover the attenuation: a numerical approach. Geophysical Journal International181(3), 1687–1700 (2010). [Google Scholar]
- 26.Lawrence, J. F., Denolle, M., Seats, K. J. & Prieto, G. A. A numeric evaluation of attenuation from ambient noise correlation functions. Journal of Geophysical Research: Solid Earth118(12), 6134–6145 (2013). [Google Scholar]
- 27.Boschi, L., Magrini, F., Cammarano, F. & van Der Meijde, M. On seismic ambient noise cross-correlation and surface-wave attenuation. Geophysical journal international219(3), 1568–1589 (2019). [Google Scholar]
- 28.Magrini, F., & Boschi, L. Surface-wave attenuation from seismic ambient noise: Numerical validation and application, Journal of Geophysical Research: Solid Earth 126 (1), e2020JB019865 (2021).
- 29.Prieto, G., Lawrence, J., Beroza, G. Anelastic earth structure from the coherency of the ambient seismic field, Journal of Geophysical Research: Solid Earth 114 (B7) (2009).
- 30.Lawrence, J.F., Prieto, G.A. Attenuation tomography of the western United States from ambient seismic noise, Journal of Geophysical Research: Solid Earth 116 (B6) (2011).
- 31.Liu, X., Beroza, G.C., Yang, L., & Ellsworth, W.L. Ambient noise Love wave attenuation tomography for the LASSIE array across the Los Angeles basin, Science Advances 7 (22) (2021) eabe1030. [DOI] [PMC free article] [PubMed]
- 32.Borleanu, F. et al. Seismic attenuation tomography of Eastern Europe from ambient seismic noise analysis. Geophysical Journal International236(1), 547–564 (2024). [Google Scholar]
- 33.Di Paolo, F. et al. La Palma island (Spain) geothermal system revealed by 3D magnetotelluric data inversion. Scientific reports10(1), 18181 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Cabrera-Pérez, I. et al. Geothermal and structural features of La Palma island (Canary Islands) imaged by ambient noise tomography. Scientific Reports13(1), 12892 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Camacho, A.G., Fernández, J., González, P., Rundle, J., Prieto, J.F., & Arjona, A. Structural results for La Palma island using 3-D gravity inversion, Journal of Geophysical Research: Solid Earth 114 (B5) (2009). 10.1029/2008JB005628 .
- 36.Montesinos, F. G. et al. Insights into the Magmatic Feeding System of the 2021 Eruption at Cumbre Vieja (La Palma, Canary Islands) Inferred from Gravity Data Modeling. Remote Sensing15(7), 1936 (2023). [Google Scholar]
- 37.Ancochea, E. et al. Constructive and destructive episodes in the building of a young oceanic island. La Palma, Canary Islands, and genesis of the Caldera de Taburiente, Journal of Volcanology and Geothermal Research60(3–4), 243–262. 10.1016/0377-0273(94)90054-X (1994). [Google Scholar]
- 38.D’Auria, L. et al. Rapid magma ascent beneath La Palma revealed by seismic tomography. Scientific Reports[SPACE]10.1038/s41598-022-21818-9 (2022). [DOI] [PMC free article] [PubMed]
- 39.Przeor, M., Castaldo, R., D’Auria, L., Pepe, A., Pepe, S., Sagiya, T., Solaro, G., Tizzani, P., Barrancos Martínez, J., & Pérez, N. Geodetic imaging of magma ascent through a bent and twisted dike during the Tajogaite eruption of 2021 (La Palma, Canary Islands), Scientific Reports 14 (1), 212 (2024). [DOI] [PMC free article] [PubMed]
- 40.Carracedo, J. C. et al. The 2021 eruption of the Cumbre Vieja volcanic ridge on La Palma. Canary Islands, Geology Today38(3), 94–107. 10.1111/gto.12388 (2022). [Google Scholar]
- 41.Seydoux, L., Shapiro, N. M., de Rosny, J., Brenguier, F. & Landès, M. Detecting seismic activity with a covariance matrix analysis of data recorded on seismic arrays. Geophysical Journal International204(3), 1430–1442 (2016). [Google Scholar]
- 42.Bensen, G. et al. Processing seismic ambient noise data to obtain reliable broad-band surface wave dispersion measurements. Geophysical Journal International169(3), 1239–1260 (2007). [Google Scholar]
- 43.Cupillard, P., Stehly, L. & Romanowicz, B. The one-bit noise correlation: a theory based on the concepts of coherent and incoherent noise. Geophysical Journal International184(3), 1397–1414 (2011). [Google Scholar]
- 44.Truong, C., Oudre, L. & Vayatis, N. Selective review of offline change point detection methods. Signal Processing167, 107299 (2020). [Google Scholar]
- 45.Del Pezzo, E., Ibanez, J., Morales, J., Akinci, A. & Maresca, R. Measurements of intrinsic and scattering seismic attenuation in the crust. Bulletin of the Seismological Society of America85(5), 1373–1380 (1995). [Google Scholar]
- 46.Bianco, F., Del Pezzo, E., Castellano, M., Ibanez, J. & Di Luccio, F. Separation of intrinsic and scattering seismic attenuation in the Southern Apennine zone. Italy, Geophysical Journal International150(1), 10–22 (2002). [Google Scholar]
- 47.Del Pezzo, E. & Ibáñez, J. M. Seismic coda-waves imaging based on sensitivity kernels calculated using an heuristic approach. Geosciences10(8), 304 (2020). [Google Scholar]
- 48.Cabrera-Pérez, I. et al. Spatio-temporal velocity variations observed during the pre-eruptive episode of La Palma 2021 eruption inferred from ambient noise interferometry. Scientific Reports13(1), 12039 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Aster, R.C., Borchers, B., & Thurber, C.H. Parameter estimation and inverse problems, Elsevier, (2018).
- 50.Luu, K. disba: Numba-accelerated computation of surface wave dispersion. https://doi.org/10.5281/zenodo.3987395. https://github.com/keurfonluu/disba
- 51.Di Paolo, F. et al. La Palma island (Spain) geothermal system revealed by 3D magnetotelluric data inversion. Scientific reports10(1), 1–8. 10.1038/s41598-020-75001-z (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52.Serrano, I., Dengra, M., Almendros, F., Torcal, F., & Zhao, D. Seismic anisotropy tomography beneath La Palma in the Canary Islands, Spain, Journal of Volcanology and Geothermal Research, 107870 (2023).
- 53.Prieto, J. F. et al. Geodetic and Structural Research in La Palma, Canary Islands, Spain: 1992–2007 results. Pure and applied geophysics166(8–9), 1461–1484. 10.1007/s00024-009-0505-2 (2009). [Google Scholar]
- 54.Padrón, E. et al. Dynamics of diffuse carbon dioxide emissions from Cumbre Vieja volcano. La Palma, Canary Islands, Bulletin of Volcanology77(4), 1–15. 10.1007/s00445-015-0914-2 (2015). [Google Scholar]
- 55.Padrón, E. et al. Helium emission at Cumbre Vieja volcano. La Palma, Canary Islands, Chemical Geology312, 138–147. 10.1016/j.chemgeo.2012.04.018 (2012). [Google Scholar]
- 56.Cabrera Pérez, I., D’Auria, L., Soubestre, J., del Pezzo, E., Prudencio, J., Ibáñez, J.M., Jiménez-Mejías, M., Padilla, G.D., Barrancos, J., & Pérez, N.M. Results: 3-D Intrinsic Attenuation Tomography using Ambient Seismic Noise: application to La Palma island (Canary Islands) (2024). 10.5281/zenodo.12790569 .
- 57.Hunter, J. D. Matplotlib: A 2D graphics environment. Computing in science & engineering9(03), 90–95. 10.1109/MCSE.2007.55 (2007). [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
All the Empirical Green’s Functions, intrinsic attenuation values, 2D intrinsic attenuation maps, and 1D depth intrinsic attenuation models obtained in this work are available in the Zenodo repository at Cabrera-Pérez et al56.






