. 2024 Sep 25;23(6):2005–2023. doi: 10.1007/s10237-024-01879-7

Multiscale computational analysis of the steady fluid flow through a lymph node

Alberto Girelli 1, Giulia Giantesio 1,2, Alessandro Musesti 1, Raimondo Penta 3,✉
PMCID: PMC11554713  PMID: 39320689

Abstract

Lymph Nodes (LNs) are crucial to the immune and lymphatic systems, filtering harmful substances and regulating lymph transport. LNs consist of a lymphoid compartment (LC) that forms a porous bulk region, and a subcapsular sinus (SCS), which is a free-fluid region. Mathematical and mechanical challenges arise in understanding lymph flow dynamics. The highly vascularized lymph node connects the lymphatic and blood systems, emphasizing its essential role in maintaining the fluid balance in the body. In this work, we describe a mathematical model in a steady setting to describe the lymph transport in a lymph node. We couple the fluid flow in the SCS governed by an incompressible Stokes equation with the fluid flow in LC, described by a model obtained by means of asymptotic homogenisation technique, taking into account the multiscale nature of the node and the fluid exchange with the blood vessels inside it. We solve this model using numerical simulations and we analyze the lymph transport inside the node to elucidate its regulatory mechanisms and significance. Our results highlight the crucial role of the microstructure of the lymph node in regularising its fluid balance. These results can pave the way to a better understanding of the mechanisms underlying the lymph node’s multiscale functionalities which can be significantly affected by specific physiological and pathological conditions, such as those characterising malignant tissues.

Keywords: Multiscale modelling, Lymph flow, Numerical simulations, Physiological data

Introduction

Lymph Nodes (LNs) are essential components of the lymphatic system, acting as filters that eliminate harmful substances like bacteria, viruses, and waste products. The lymph node plays a crucial role in both the immune and lymphatic systems, serving as a vital component in safeguarding the body against infections and diseases and regulating lymph transport. The main immunological function of the lymph node is achieved by hosting lymphocytes, such as B and T cells, which travel through the bloodstream and reside in the nodes. B cells generate antibodies that specifically attach to antigens, triggering an immune response. When activated, B cells can differentiate into plasma cells that release antibodies or memory cells that provide defense in subsequent encounters. Additionally, specialized antigen-presenting cells (APCs), like dendritic cells (DCs), capture and process antigens from diverse sources. These cells then migrate to the lymph nodes, presenting the antigens to T cells, activating them, and kickstarting the adaptive immune response.

Interstitial fluid, known as lymph once it enters the lymphatic system, plays a crucial role in transporting immune cells, proteins, cancer cells, drugs, and other substances (O’Melia et al 2019; Arasa et al 2021; Birmingham et al 2020; Apoorva et al 2018; Permana et al 2021). When lymph transport is compromised, it can result in lymphœdema, a condition characterized by an abnormal accumulation of fluid in the tissues. Lymph nodes play a major role in regulating lymph transport: indeed one of the causes of lymphœdema is the excision and removal of lymph nodes (Moore Jr and Bertram 2018; Tobbia et al 2009). The lymph transport within the node is important from a biological point of view, but it also presents some interesting mathematical and mechanical challenges. From a mechanical perspective, the lymph node comprises two primary components: the lymphoid compartment (LC), which forms the porous bulk region of the node, and the subcapsular sinus (SCS), a narrow free-fluid channel located near the wall that surrounds the LC (Margaris and Black 2012). The lymph can permeate the LC from the SCS through a network of conduits established by fibroblastic reticular cells (FRC) that form the porous structure of the node (Novkovic et al 2020; Grebennikov et al 2016; Savinkov et al 2017). Initially, the lymph flows inside the subcapsular sinus of the node, and then a part of the lymph goes into the lymphoid compartment and the remaining part (the majority) leaves the node. The dendritic cells and macrophages present in the lymph are transported at the interaction surface between the SCS and the LC, initiating the immune response. The lymph node is a highly vascularized organ, and inside the LC compartment, there are blood vessels that allow the exchange of fluid and substances, making the LN an important connection between the lymphatic and the blood system.

The movement of lymph within the lymph node is a highly significant and intriguing physical process. It involves a complex multiscale architecture with an intricate microenvironment and the interplay between the free-fluid region in the subcapsular sinus and the porous lymphoid compartment. Moreover, this process integrates interactions between the lymphatic and blood systems, crucial for immune surveillance and response. Understanding these dynamics is pivotal, as deviations can lead to various pathologies, from lymphœdema to cancer metastasis. Thus, the lymph node serves as a connection where fluid dynamics, immune function, and physiological intricacies converge, shaping our understanding of health and disease. However, yet, only a few mathematical models in literature explore it (Novkovic et al 2018; Shanti et al 2018; Jayathungage Don et al 2023). An image-based modeling approach to obtain data regarding the internal structure of the lymph node is proposed in Cooper et al (2016, 2018), where they used these data to find the permeability of a Darcy equation used to describe the lymph flow in the whole node. Another computational flow model is studied in Jafarnejad et al (2015), in which they study a mouse popliteal LN in an idealized spheroidal geometry, differentiating the fluid flow in the SCS (using a Navier-Stokes equation) and the fluid flow in the LC (using a Darcy-Brinkman equation). Setukha and Tretiakova (2022) propose numerical simulation using boundary integral equations to simulate the fluid flow in the lymph node. In the literature, some more computational models describe the fluid flow in a lymph node. In Tretiakova et al (2021) they develop an artificial neural network model based on Setukha and Tretiakova (2022) and on the experimental results of Adair et al (1982); Adair and Guyton (1983, 1985) to describe the lymph node drainage function. A three-dimensional geometry of the fibroblastic reticular cell graph network generated by an object-oriented computational algorithm is developed in Grebennikov et al (2016); Savinkov et al (2017) to study the lymph flow through the conduit system network. Another interesting approach used to describe the fluid flow within the node is to use a microfluidic platform, like in Shanti et al (2020) the authors simulate the fluid flow in a microenvironment mimicking the lymph node properties; another microfluidic platform that recreates the lymph node’s subcapsular sinus microenvironment is developed by Birmingham et al (2020), where they investigate how physiological flow patterns impact the adhesion of metastatic cancer cells. All the papers presented above have a computational and experimental nature; in Giantesio et al (2021, 2022) we have the first attempts to analytically study the lymph movement within the lymph node. An analytical and a numerical solution are presented in a time-dependent setting in simplified geometries (a cylindrical geometry in Giantesio et al (2021) and a spherical geometry in Giantesio et al (2022)), without considering the drainage of the blood vessels. In particular, in Giantesio et al (2022) we coupled the lymph flow in the subcapsular sinus with the flow in the lymphoid compartment using stream functions, without considering the blood vessels and the fluid exchange within them. The drainage function of the blood vessels inside the node and the multiscale nature of the latter are considered in Girelli et al (2023), obtaining a rigorous mathematical model using the asymptotic homogenization technique (Gerisch et al 2018; Hornung 1997; Auriault et al 2009) describing the fluid flow inside both the FRC and the blood vessels networks, without considering the subcapsular sinus, in a steady setting. We found an analytical solution, in a simplified spherical geometry, which describes the fluid flow and the fluid exchange between the FRC and the blood vessels. In this work, we extend the results of our previous work Girelli et al (2023) taking into account the fluid flow in the subcapsular sinus, coupling this flow with the flow inside the lymphoid compartment in a more realistic geometry, giving detailed results for the entire lymph node.

In Sect. 2, we recall the steady mathematical model that describes the fluid flow inside both the subcapsular sinus and the lymphoid compartment. In Sect. 3 we describe the numerical simulations used to solve the steady problem and we describe the results using physiological parameters obtained from the lymph node literature. In particular, in Sect. 3.1 we study the steady lymph flow in a spherical geometry and we compare the results with the analytical founding of Girelli et al (2023), and Sect. 3.2 is devoted to the steady lymph flow in an oblate spheroidal geometry, which is a more realistic geometry for a lymph node (Jafarnejad et al 2015; Tretiakova et al 2021; Margaris and Black 2012; Giantesio et al 2021; Shanti et al 2020; O’Melia et al 2019).

Mathematical model

In this section, we introduce the mathematical model that we use to describe the fluid flow inside the lymph node in a steady setting. In Fig. 1 we can see a sketch of the geometry of our problem, showing the subcapsular sinus (SCS), the lymphoid compartment (LC), and, on the right-hand side, the microstructure of the conduit system network, formed by FRC lymph conduits represented by the geometry Ωm and the blood vessels represented by Ωv. We emphasize that the cylinders forming the geometry Ωv physically represent vascularized regions rather than individual vessels, as described in Girelli et al (2023).

Fig. 1.

Fig. 1

A 2D representation of the microscale and macroscale geometries. On the left-hand side, there is a sketch of the macroscale of the lymph node. On the right-hand side, there is the periodic cell representing the microscale

We suppose that the lymph is an incompressible Newtonian fluid similar to water (Moore Jr and Bertram 2018) so that the fluid in the subcapsular sinus can be described by the steady Stokes equation due to the small velocity and small characteristic length

μΔuf=∇pf,∇·uf=0, 1

where μ is the viscosity, uf is the velocity in the SCS, and pf is the pressure in the SCS.

For the lymphoid compartment (porous bulk region of the lymph node) we use the model proposed in Girelli et al (2023) to describe the fluid flow and the fluid exchange between the lymph and the blood vessels. Here we summarize the model; see Girelli et al (2023) for more details about its derivation.

First of all, we define the average operator as

⟨h⟩Ωγ=1|Ωγ|∫Ωγhdy,γ=m,v, 2

where y is the variable that describes the microscale problem, which is connected to the macroscale variable x by the relationship y=x/ϵ, with

ϵ=d/L≪1,

d is the microscale characteristic length related to the distance of the centers of the cylinders in the cell domain of Fig. 1 (d physically represents the distance between two vascularized regions) and L is the macroscale characteristic length.

The macroscopic model of the fluid flow for the FRC phase Ωm is as follows

⟨um(0)(x,y)⟩Ωm=-d2μ⟨Wm(x,y)⟩Ωm∇xpm(0)(x), 3
∇x·⟨um(0)(x,y)⟩Ωm=-LpStot|Ωmtot|pm(0)(x)-pv(0)(x)-σπm-πv, 4

where um(0) and pm(0) are the leading-order velocity and pressure of the asymptotic homogenization expansion presented in the model of Girelli et al (2023) of the phase Ωm, respectively; Lp is a quantity that describes the geometry and the tissue wall material at the intersection between the two phases described in ms−1 Pa−1 (Waniewski 2006), Stot is the total blood vessels surface, |Ωmtot| is the total volume of the phase Ωm, σ is the Staverman’s reflection coefficient that describes the leakiness of the capillary membrane to proteins, πv and πm are the oncotic pressure of phase Ωv and Ωm, respectively, and Wm is a second-order tensor obtained as the solution of the following cell problem (obtained by the asymptotic homogenization technique in Girelli et al 2023):

Km-1x,yWmx,y-μ∗ΔyWmx,y-I+∇ygmx,yT=0inΩm,∇y·Wmx,y=0inΩm,WmTx,yn=0onΓ,WmT(x,y)τ=-Kmx,yα∇yWmTx,ynτonΓ,gmx,yΩm=0inΩm. 5

Here Γ is the interface between the phases Ωm and Ωv, n is the outer normal to Ωm, τ any tangential vector to the interface Γ, I is the second-order identity tensor, Km is the hydraulic conductivity of the phase Ωm, μ∗ is the ratio between the effective viscosity μe (Brinkman 1949) and the fluid viscosity μ, α is the Beavers-Joseph-Saffman parameter (Beavers and Joseph 1967; Saffman 1971), and gm is a vector obtained exploiting the asymptotic homogenization technique in Girelli et al (2023). The last equation of system (5) ensures the uniqueness of the solution.

For the macroscopic model of the fluid flow for the blood vessel phase Ωv, we have

⟨uv(0)(x,y)⟩Ωv=-d2μ⟨Kv(x,y)I+(∇ygv(x,y))T⟩Ωv∇xpv(0)(x) 6
∇x·⟨uv(0)(x,y)⟩Ωv=LpStot|Ωvtot|pm(0)(x)-pv(0)(x)-σπm-πv, 7

where Kv is the hydraulic conductivity of the phase Ωv, uv(0) and pv(0) are the leading-order velocity and pressure of the asymptotic homogenization expansion presented in the model of Girelli et al (2023) of the phase Ωv, respectively; gv is a vector obtained by the solution of the following cell problem (obtained by the asymptotic homogenization technique in Girelli et al (2023)):

∇y·∇ygv(x,y)Kv(x,y)T=-∇y·Kv(x,y)T,inΩv∇ygv(x,y)Kv(x,y)T·n=-Kv(x,y)T·nonΓ,⟨gv(x,y)⟩Ωv=0inΩv. 8

Again, the last equation of system (8) ensures the uniqueness of the solution.

We assume to have an afferent lymphatic vessel at the upper part of the lymph node and an efferent lymphatic vessel at the lower part. The boundary conditions that we impose are: uniform flow velocity vin as inlet condition in the upper lymphatic vessel, the pressure pout as outlet condition in the lower lymphatic vessel, no-slip condition at the external wall. At the macroscopic interface ΓM between the free fluid region (SCS) and the porous region (LC) we impose the following interface conditions (Discacciati and Quarteroni 2009)

uf·nM=⟨um(0)⟩Ωm·nM 9
-T(uf,pf)nM·nM=pm(0) 10
uf·τjM=-KmαMnM·∇uf·τjM 11

where T is the Cauchy stress tensor of the free-fluid region, Km is the macroscopic permeability (obtained from the cell problem (5) of the phase Ωm, that in our specific case is constant due to the isotropy of the porous medium, i.e. Km(x)≡KI, where I is the second order identical tensor), αM is a parameter that needs to be estimated and depends on the physicochemical properties of the interface (Irons et al 2017), nM is the normal vector related to ΓM, and τjM for j=1,2 are the tangents related to the normal nM. The last interface condition is the so-called Beavers-Joseph-Saffman boundary condition (BJS). The BJS is an interface condition formulated experimentally in Beavers and Joseph (1967); Saffman (1971).

Equation (11) can be simplified letting αM→∞, which gives (Discacciati and Quarteroni 2009; Auriault 2010)

uf·τj=0onΓM,j=1,2. 12

Using (12) in place of (11) we get a difference of about ϵ with respect to the whole BJS (Discacciati and Quarteroni 2009).

Remark 1

We note that the Beavers-Joseph-Saffman boundary conditions were found experimentally in Beavers and Joseph (1967); Saffman (1971) and demonstrated in Jäger and Mikelić (2000, 2009), but only in a 2D laminar case (as mentioned in Auriault (2010)), and the extension to a generic geometry is non-trivial (Eggenweiler and Rybak 2021; Shipley and Chapman 2010). Moreover, in Auriault (2010) they employ an asymptotic homogenization expansion to study the interface between a free-fluid region and a porous region, and they found that the simplified boundary condition (12) is also valid for correctors of order higher than ϵ. For these reasons, for most of the paper, we will consider the simplified boundary condition (12), although some comparisons with the BJS boundary condition are made for the sake of completeness.

Numerical simulations

In this section we solve numerically the macroscopic flow related to the model described in the previous section, aimed at coupling the motion of the flow in the subcapsular sinus (SCS) and the lymphoid compartment (LC) in a steady setting. Indeed, in Girelli et al (2023), we supposed a given pressure distribution for the SCS and we imposed this pressure as a boundary condition for the porous bulk region (the LC). However, in general, we need to couple these two domains.

The physiological data are the same as in Girelli et al (2023, Appendix B), and they are summarized in Table 1. The cell problems (5) and (8) are solved using COMSOL Multiphysics in the same way as we did in Girelli et al (2023, Appendix C); the solution method is given in Sect. 4 for the reader’s convenience.

Table 1.

Physiological and estimated parameters. For a complete review, we refer to Girelli et al (2023, Appendix B)

Name Physiological Range/Value Description
R 0.49 mm Macroscopic radius (Birmingham et al 2020; Giantesio et al 2022)
a, b 0.5 mm, 0.35 mm Major and minor spheroidal semiaxes (Jafarnejad et al 2015)
h 0.01 mm Subcapsular sinus height (Jafarnejad et al 2015; Ohtani and Ohtani 2008)
μ 1mgmms Viscosity (Moore Jr and Bertram 2018; Bertram et al 2017)
ϕ 0.75 Porosity (Shanti et al 2020)
μe μϕ Effective viscosity (Ochoa-Tapia and Whitaker 1995a, b; Brinkman 1949; Tan and Pillai 2009)
ρ0 1mgmm3 Density (Moore Jr and Bertram 2018; Bertram et al 2017)
K^m 3.84×10-9 mm2 Permeability of the interstitium (Shanti et al 2020; Savinkov et al 2017)
σ 0.88-0.9 Staverman’s coefficient (Jafarnejad et al 2015; Cooper et al 2016, 2018; Tretiakova et al 2021)
πv-πm 3.41×105-2.08×106 mPa Oncotic pressure difference (Jafarnejad et al 2015; Cooper et al 2016, 2018; Tretiakova et al 2021; Adair et al 1982; Adair and Guyton 1983, 1985; Stohrer et al 2000)
Lp 5.475×10-12-3.67×10-8mmsmPa Hydraulic conductivity of the blood vessel walls(Jafarnejad et al 2015; Cooper et al 2016, 2018; Tretiakova et al 2021)
p¯v 6.67×105-1.066×106 mPa Mean blood vessel pressure (Jafarnejad et al 2015; Cooper et al 2016, 2018; Tretiakova et al 2021)
Stot,|Ωvtot| 13.4 mm2, 0.0322 mm3 Blood vessel surface and volume (Jafarnejad et al 2019; Kelch et al 2015)
N 1310 Number of cells (Girelli et al 2023, Appendix B)
rc,d 1.7×10-3 mm, 2×10-2 mm Microscale cylinders radius and mean distance (Girelli et al 2023)
L 1 mm Coarse scale characteristic length
Kvd2μ 1.1×10-6mm3smg Hydraulic conductivity of the blood vessels computed using the Kozeny-Carman formula (Kozeny 1927; Carman 1997; Girelli et al 2023)
K¯m 3.65×10-9mm3smg Macroscopic interstitial hydraulic conductivity (solving system (5))
K¯v 4.12×10-7mm3smg Macroscopic blood hydraulic conductivity (solving system (8))
vin 0.22mms Inlet velocity (Blatter et al 2016)
α 1 Beavers-Joseph-Saffman parameter of the cell problem (5)

Here we discuss the weak formulation in the general case of the boundary conditions (9)– (11). Consider a test function

w∈Wg={w∈H1(Ω):wΓD=g},

where Ω is the domain of the problem, H1(Ω) is the usual Sobolev space, and ΓD is the portion of the boundary where we have the Dirichlet boundary condition u|∂ΓDf=g; by using the classical weak formulation of the Stokes equation (1), we can focus on the boundary term of this weak form -∫ΓMn·T(uf,pf)w, so that the weak formulation of the interface conditions (9-11) can be written as (Discacciati and Quarteroni 2009)

-∫ΓMn·T(uf,pf)w=-∫ΓMn·T(uf,pf)·nw·n-∫ΓM∑j=12n·T(uf,pf)·τjw·τj, 13

and hence we have, using (10) and (11)

-∫ΓMn·T(vf,pf)w=∫ΓMpm(0)(w·n)+∫ΓM∑j=12μαMKuf·τjw·τj=∫ΓM(pm(0)·n)w+∫ΓM∑j=12μαMKuf·τj·τjw. 14

We use the finite element method to solve numerically the Stokes equation and the macroscopic model given in Sect. 2 using COMSOL Multiphysics. To have more information about the weak formulation of the Stokes equation, we refer to Formaggia et al (2009); Giantesio et al (2022). We implement this flow in COMSOL using the creeping flow module for the Stokes equation (1), with the Taylor-Hood element P23-P1; this means that, given a triangulation T of the domain Ω, we approximate the velocity and the pressure with the piecewise polynomial spaces P23=P2(T)3∩H01(Ω) and P1=P1(T)∩L02(Ω), respectively, where Pk(T)={g∈C(Ω):gT∈P2,∀T∈T}, H01(Ω)={w∈H1(Ω):w|∂Ω=0}, L02(Ω)={w∈L2(Ω):w|∂Ω=0}, H1(Ω) is a Sobolev space and L2(Ω) is a Banach space. To implement the boundary condition (14), we use the general stress boundary condition of COMSOL. Moreover, from equations (3), (4), (6), and (7), we have that the Darcy problems can be written as diffusion problems for the pressure and we refer to Quarteroni and Valli (1994); Johnson (1987); Quarteroni et al (2007) for more information about the weak formulation and the numerical methods used to solve this kind of problem. For these equations, we use Darcy’s law module of COMSOL with a quadratic discretization. We solve these equations together using the fully coupled MUMPS direct solver.

Numerical simulations—spherical geometry

In this section, we numerically solve the model described in the previous sections in a simplified spherical geometry. We can see the 3D geometry of our problem in Fig. 2, where we refer to 2D concepts such as the polar angle and arc length because the 3D geometry exhibits symmetrical properties that allow for these 2D measurements to be relevant. Due to this symmetry, we have that the velocity is near zero at the axis of symmetry, i.e. at polar angle 0 and π in accordance with the results found with the stream function approach used to solve the Stokes equation (see Giantesio et al 2022). The numerical results have been compared and validated with the analytical solution given in Girelli et al (2023).

Fig. 2.

Fig. 2

On the left, the mesh of the 3D simplified spherical geometry of our problem, inspired by a mouse popliteal lymph node as in Giantesio et al (2022); Girelli et al (2023). On the right, a representative plot of the geometric section parameters utilized throughout the entire paper

First of all, we want to see the effect of the Beavers-Joseph-Saffman parameter αM in the interface condition (11). As we can see from the interface condition (11), we obtain the simplified interface condition (12) when αM→∞. In Fig. 3 we can see the velocity magnitude and the pressure values with αM=1 and αM→∞, and, as we can see, we have that this parameter does not influence much the velocity and the pressure in the whole domain (Shipley and Chapman 2010; Irons et al 2017). For this reason and for the reasons explained in Remark 1, from now on we fix the value αM→∞, which means we use the simplified interface condition (12).

Fig. 3.

Fig. 3

The first two plots (upper plots) represent the velocity magnitude in the SCS in mms with respect to the arc length spanning the polar angle from 0 to π as shown in Fig. 2, with two different value of αM=1 and αM→∞. The lower two plots represent the pressure values in the LC in mPa with αM→∞ and the pressure difference between the pressures pm with the values of αM→∞ and αM=1, normalized with respect to pout. As we can see, the general value does not change much with respect to αM. Here we used the parameters vin=0.22mms, pout=6.18×105 mPa, πv-πm=1.02×106 mPa, Lp=5.475×10-11mms mPa and p¯v=1.06×106 mPa

In Fig. 4 we can see the interstitial pressure pm values in the LC varying the parameter Lp. We have similar behavior to the one found in Girelli et al (2023): increasing Lp decreases the minimum of the interstitial pressure pm (and increasing the maximum of the blood vessels pressure pv) and moves the minimum towards the center of the node. This behavior is due to a combination of the pressure variation given by the pressure of the Stokes flow in the SCS and the fluid exchange between phases. The values we found with these simulations are similar to the ones found in Girelli et al (2023) but slightly different: this is why it is important to take into account the coupling between the SCS and the LC.

Fig. 4.

Fig. 4

The interstitial pressure values pm in the LC with different values of Lp. Here we used the parameters vin=0.22mms, pout=6.18×105 mPa, πv-πm=1.02×106 mPa, and p¯v=1.06×106 mPa

Given a uniform inlet velocity of vin=0.22mms, the inlet fluid flow computed numerically is ≈1.083×10-3mm3s (with a relative error of about 1.5% from the value computed analytically of 1.1×10-3mm3s). Part of the lymph goes from the SCS to the LC (and then back to the blood circulation), and the remaining part goes out from the efferent lymphatic vessels: these quantities change with the parameter Lp, and we can see some results in Table 2. The sum of the columns “Outlet Flow” and “SCS → LC” must result approximately in the inlet fluid flow value ≈1.083×10-3mm3s. As expected, increasing Lp means increasing the fluid flow from the SCS to the LC, and it follows a lesser outlet fluid flow. We can see this behavior in Fig. 5, where the velocity near the efferent lymphatic vessel decreases as Lp increases.

Table 2.

Outlet fluid flow and the fluid flow passing through the external surface of the LC from the SCS in mm3s varying the capillaries permeability Lp. Here we used the parameters vin=0.22mms, pout=6.18×105 mPa – 4×105 mPa, πv-πm=1.02×106 mPa, and p¯v=1.06×106 mPa

Lp Outlet Flow SCS → LC pout
5.475×10-12mms mPa 1.05×10-3mm3s 3.44×10-5mm3s 6.18×105 mPa
1×10-11mms mPa 1.02×10-3mm3s 6.28×10-5mm3s
1.6×10-11mms mPa 9.83×10-4mm3s 1×10-4mm3s
3×10-11mms mPa 8.97×10-4mm3s 1.87×10-4mm3s
5.475×10-11mms mPa 7.44×10-4mm3s 3.4×10-4mm3s
7.94×10-11mms mPa 5.93×10-4mm3s 4.9×10-4mm3s
5.475×10-12mms mPa 1.065×10-3mm3s 1.84×10-5mm3s 4×105 mPa
1×10-11mms mPa 1.058×10-3mm3s 3.35×10-5mm3s
1.6×10-11mms mPa 1.01×10-3mm3s 5.35×10-5mm3s
3×10-11mms mPa 9.83×10-4mm3s 1×10-4mm3s
5.475×10-11mms mPa 8.8×10-4mm3s 1.82×10-4mm3s
7.94×10-11mms mPa 8×10-4mm3s 2.62×10-4mm3s

Fig. 5.

Fig. 5

The velocity magnitude in the center of the SCS with respect to the arc length spanning the polar angle from 0 to π as shown in Fig. 2, with different values of Lp. Here we used the parameters vin=0.22mms, pout=6.18×105 mPa, πv-πm=1.02×106 mPa, and p¯v=1.06×106 mPa

We observe that varying the other parameters gives results with behavior similar to what we found in Girelli et al (2023).

The plots and the data above are obtained with pout=6.18×105 mPa, that is a value inspired by the experiments of Bouta et al (2014) (the minimum of the value range); in Jafarnejad et al (2015) they used a value of pout=4×105 mPa, and in Cooper et al (2016, 2018) they used a value of pout=0 mPa. Considering that the value of the pressure is important to study the fluid exchange between phases, we want to see the differences between using a different outlet pressure. Hence now we fix pout=4×105 mPa. In the second part of Table 2 we can see the fluid flow computed with different Lp in this case; as we can see, to have the same outlet fluid flow (and the same SCS → LC fluid flow) as in the case with pout=6.18×105 mPa, we need a higher value of Lp. If we fix the same outlet fluid flow value of ≈9.83×10-4mm3s (that is chosen by the fact that more than 90% of the lymph remain in the SCS without entering the LC (Jafarnejad et al 2015)), we have Lp=1.6×10-11mms mPa for pout=6.18×105 mPa and a value of Lp=3×10-11mms mPa for pout=4×105 mPa. As we can see in Fig. 6, with these different values we have the same pressure behavior and range but with different pressure values.

Fig. 6.

Fig. 6

The pressure values in the LC with different values of pout and Lp but with the same fluid flow values of Tables 2 and 3.1. Here we used the parameters vin=0.22mms, πv-πm=1.02×106 mPa, and p¯v=1.06×106 mPa

In Fig. 7 we can see the outlet flow computed in the efferent lymphatic vessel varying p¯v and Lp. As we can see, increasing Lp results in decreasing the outlet flow (and a consequent increase of the fluid that goes into the LC, as we can see above); instead, increasing p¯v results in increasing the outlet flow (and a consequent decrease of the fluid that goes into the LC). Moreover, we can see that there is a linear relation between the outlet flow computed and the variation of the parameters p¯v and Lp: a similar behavior is reported in Jafarnejad et al (2015).

Fig. 7.

Fig. 7

The outlet flow computed in the efferent lymphatic vessel with different values of p¯v (on the left) and Lp (on the right), with the fluid flow values of Table 1. Here we used the parameters vin=0.22mms, πv-πm=1.02×106 mPa, Lp=5.475×10-11mms mPa (for the plot on the left) and p¯v=1.06×106 mPa (for the plot on the right)

From the simulations we can estimate the pressure p¯v for which we have an inversion of the fluid exchange flow direction: when we have pout=6.18×105 mPa, we have a flow inversion at p¯v=1.54×106mPa≈11.6 mmHg, similar to the ones found in Girelli et al (2023); instead, for pout=4×105 mPa, we have a flow inversion at p¯v=1.35×106mPa≈10.1 mmHg, similar to the one found in Jafarnejad et al (2015).

In Fig. 8 we can see the velocity magnitude and the velocity behavior inside the lymph node: as we can see, the velocity inside the porous bulk region (the lymphoid compartment) is extremely lower with respect to the one in the subcapsular sinus. The velocities that we found in our simulations inside the lymphoid compartment are in agreement with the founding in the literature, where the velocity range from 1.5×10-5mms to 6×10-4mms (Shanti et al 2020; Chary and Jain 1989; Jafarnejad et al 2015; Tomei et al 2009; Dafni et al 2002). If we compare this solution with the one that we found analytically in Girelli et al (2023) using a given pressure distribution found by the stream function approach in Giantesio et al (2022), the qualitative behavior remains the same (a higher pressure near the inlet, a lower pressure near the outlet, and a lower pressure region near the center of the node, and the same for the velocity), but here we have a higher maximum velocity respect to the values we found analytically: this is because here we couple the fluid flow in the SCS with the fluid flow in the LC, and this allows us to find more precise boundary data for the LC.

Fig. 8.

Fig. 8

The velocity magnitude computed in the subcapsular sinus center with respect to the spherical arc length spanning the polar angle from 0 to π as shown in Fig. 2 (upper on the left) and on the lymphoid compartment (upper on the right) and the velocity magnitude together with the velocity arrows in the LC (lower), with the fluid flow values of Tables 2. Here we used the parameters vin=0.22mms, πv-πm=1.02×106 mPa, Lp=5.475×10-11mms mPa and p¯v=1.06×106 mPa

Numerical simulations—oblate spheroidal geometry

In this section we numerically solve the model presented in the previous sections in a more realistic lymph node geometry. Indeed, a lymph node generally has an oblate spheroidal shape (Birmingham et al 2020; Jafarnejad et al 2015; Tretiakova et al 2021; Giantesio et al 2021). We represent this geometry in the x-z plane in this way

xz=acosθbsinθ, 15

with major semiaxis a=0.5 mm, minor semiaxis b=0.35 mm (Jafarnejad et al 2015), and subcapsular sinus thickness h=10 μm (Jafarnejad et al 2015; Giantesio et al 2022). It follows that the parametric equation that describes the LC geometry on a x-z plane is

xz=acosθbsinθ-h1a2cosθ1b2sinθcos2θa4+sin2θb4. 16

We can see the 3D geometry in Fig. 9 (where we rotate the 2D geometry described above with respect to the z-axis).

Fig. 9.

Fig. 9

On the left, the mesh of the 3D geometry of our problem, inspired by a mouse popliteal lymph node (Jafarnejad et al 2015). On the right, a representative plot of the geometric section parameters utilized throughout the entire paper

As in Sect. 3.1, we use the no-slip interface condition (12) because, as happens in the spherical case, the behavior of the result with different αM is very similar.

We can see the shear stress at the interface between the SCS and the LC in Fig. 10 with respect to the arc length of the interface varying the inlet velocity. As we can see, we have the maximum shear stress near the inlet (arc length near zero) and then, near the outlet (arc length near π) we have a local maximum but smaller than the inlet one; this happens because part of the lymph “vanishes” from the lymph node due to the fluid exchange with the blood vessels inside it and this result in a lesser outlet flow (and lesser shear stress near the outlet). Increasing vin also increases shear stress; for the shear stress curve obtained with vin=0.58mms, we obtain the same behavior and values obtained in Jafarnejad et al (2015). The importance of this behavior at the interface lies in its direct connection to cell adhesion on the exterior of the LC, which correlates directly with shear stress (Birmingham et al 2020). Furthermore, it is worth noting that shear stress also plays a crucial role in certain pathologies, for instance, B-cell lymphoma (Apoorva et al 2018).

Fig. 10.

Fig. 10

Shear stress at the interface between the SCS and the LC in mPa varying the inlet velocity (in mms) with respect to the spheroidal arc length spanning the ellipsoidal angle from 0 to π as shown in Fig. 9. We use these chosen parameters: pout=6.18×105 mPa, πv-πm=1.02×106 mPa, Lp=5.475×10-11mms mPa and p¯v=1.06×106 mPa

In Fig. 11 we can see the interstitial pressure behavior with different Lp. As we can see, increasing Lp results in a decrease of the minimum pressure and the moving of this minimum towards the center of the node. This behavior means that, as Lp increases, more lymph moves from the lymph node to the blood vessels inside it, resulting in a lesser outlet fluid flow. We can see this behavior in Fig. 12. This is the same behavior that we found in the spherical case. Varying the other parameters results in the similar behavior we found for the spherical case in Sect. 3.1 and in Girelli et al (2023). Moreover, we have that with the same value of Lp, for the spheroidal case we have a higher outlet fluid flow. In particular, if we fix, for instance, the value Lp=3×10-11mms mPa, we have for the spherical case an outlet flow of 8.97×10-4mm3s (see Table 2), instead for the spheroidal case we have an outlet flow of 9.6×10-4mm3s.

Fig. 11.

Fig. 11

The interstitial pressure values pm in the LC with different values of Lp. Here we used the parameters vin=0.22mms, pout=6.18×105 mPa, πv-πm=1.02×106 mPa, and p¯v=1.06×106 mPa

Fig. 12.

Fig. 12

The velocity magnitude (in mm/s) in the SCS center with respect to the spheroidal arc length spanning the ellipsoidal angle from 0 to π (as shown in Fig. 9) with different values of Lp. Here we used the parameters vin=0.22mms, pout=6.18×105 mPa, πv-πm=1.02×106 mPa, and p¯v=1.06×106 mPa

We can see better how the parameters that regulate the fluid exchange between the lymph and the blood vessels affect the outlet fluid flow in the plots of Fig. 13. As we can see, increasing Lp and Δπ results in a linear decrease of the outlet fluid flow, meaning that more lymph moves in the blood vessels; instead, increasing p¯v results in a linear increase of the outlet fluid flow, meaning that less lymph moves inside the blood vessels. This behavior is in agreement with the findings of Sect. 3.1 and of Girelli et al (2023); Jafarnejad et al (2015). Moreover, for pout=6.18×105 mPa, we have a flow inversion at p¯v=1.54×106mPa≈11.6mmHg, similar to the ones found in Girelli et al (2023) and the same we found for the spherical case.

Fig. 13.

Fig. 13

The outlet flow (in mm3s) computed in the efferent lymphatic vessel with different values of Lp (upper-left), p¯v (upper right), Δπ (lower-left), and vin (lower-right, here the outlet flow is normalized with respect to the flow values of πRLV2vin, and it is dimensionless) with the fluid flow values of Table 1. Here we used the parameters (when not varying) vin=0.22mms, πv-πm=1.02×106 mPa, Lp=5.475×10-11mms mPa and p¯v=1.06×106 mPa

The last plot (lower-right) of Fig. 13 describes the variation of the outlet flow with respect to the inlet velocity vin. In this case, we normalize the outlet flow with respect to the inlet flow (computed as πRLV2vin) to see the % of the fluid that reaches the efferent lymphatic vessel; moreover, it is obvious that increasing the inlet flow results in an increasing of the outlet flow too, therefore, normalization is performed to mitigate the presence of this behavior as well. As we can see, increasing the inlet velocity vin results in an increase of the normalized outlet flow, meaning that a greater % of the lymph reaches the efferent vessel. This happens because increasing the inlet velocity means that the residence time of the lymph in the node decreases, which means a lesser time for fluid exchange inside the node. This result is found experimentally in Adair et al (1982).

In Fig. 14 we can see the velocity behavior inside both the SCS and the LC with two different values of Lp: Lp=5.475×10-11mms mPa is the same value that we used in Fig. 8 of Sect. 3.1, and Lp=2×10-11mms mPa is the value for which about 90% of the afferent lymph goes out of the lymph node from (as found in Jafarnejad et al 2015). As in the spherical case, the velocity inside the lymphoid compartment is extremely lower with respect to the one in the subcapsular sinus. The biological motivation is that B cells seem to engage in a progressive buildup of antigens over time, rather than experiencing instant activation upon encountering antigens. This implies the occurrence of multiple cycles of antigen acquisition, as indicated by Carrasco and Facundo (2007). The significance of the porous region’s remarkably low velocity becomes evident, as it grants ample time for both antigens and cells carrying antigens to locate lymphocytes and initiate their activation, a point emphasized by Shanti et al (2020). Moreover, the maximum velocity inside the LC (in the region near the inlet condition) in the spheroidal case is slightly bigger than the spherical one but remains in the literature range from 1.5×10-5mms to 6×10-4mms (Shanti et al 2020; Chary and Jain 1989; Jafarnejad et al 2015; Tomei et al 2009; Dafni et al 2002). Between the two plots with different Lp, the maximum velocity of the case with a smaller Lp is lesser than the one with a higher Lp: this is consistent because less fluid enters the LC when Lp is smaller.

Fig. 14.

Fig. 14

The velocity magnitude (in mm/s) computed at the center of the subcapsular sinus with respect to the spheroidal arc length spanning the ellipsoidal angle from 0 to π as shown in Fig. 9 (left) and the velocity magnitude together with the velocity arrows in the LC (right), with the fluid flow values of Tables 2 in a spheroidal geometry, with two different values of Lp (in mms mPa). Here we used the parameters vin=0.22mms, πv-πm=1.02×106 mPa, and p¯v=1.06×106 mPa

Cell problem numerical simulations

In this section, we recall and discuss the numerical simulations used to solve the cell problems (5) and (8) in the geometry represented in Fig. 15 and with the data of Table 1.

Fig. 15.

Fig. 15

The cell problem domains Ωv (left) and Ωm (right) in a non-dimensional form. The normalized cube has side 1 and the normalized tricylinder has radius r¯=rc/d

We assume that both porous media are isotropic, hence solutions of (5) and (8) becomes

Wm=WmI,∇xgv=GvI,

where Wm and Gv are constants due to the hypotheses used.

We solve these cell problems using COMSOL Multiphysics in the same way as we did in Girelli et al (2023, Appendix C). We report the methods and the results here for the readers’ convenience. To address the cell problem described by equation (5) within the geometry Ωm, we employ the COMSOL Brinkman equations module, using a PARDISO solver. Moreover, we use a P23-P1 discretization for the fluid and pressure variables, respectively. Figure 16 displays the velocity solution in the e1 direction. It is noteworthy that the solution remains the same across all directions due to the symmetry of the geometry and the isotropy of the porous medium.

Fig. 16.

Fig. 16

The velocity solution of cell problem (5) in the geometry Ωm in a non-dimensional form using the physiological data of Table 1

The value of the hydraulic conductivity ⟨Wm⟩Ωm in (3) computed by our simulation is

⟨Wm⟩Ωm≈9.1163×10-6. 17

We perform an adaptive mesh refinement study to analyze the mesh used in our simulation, and we find a value of

⟨Wmref⟩Ωm≈9.1187×10-6, 18

giving a relative error of ≈0.026%.

The cell problem expressed by equation (8) within the geometry Ωv takes the form of Poisson’s equation. To solve it, we employ COMSOL Poisson’s equation module using quadratic element order for discretization, and we use MUMPS as the solver. We can see the solution in Fig. 17 computed in the direction e1 (as in the previous case, we have the same solution for every direction).

Fig. 17.

Fig. 17

The solution of cell problem (8) in the geometry Ωv in a non-dimensional form using the physiological data found in Table 1

The value ⟨Gv⟩Ωv computed by our simulations for the hydraulic conductivity (6) is

⟨Gv⟩Ωv≈-0.60060. 19

Performing an adaptive mesh refinement study for this problem we find a value of

⟨Gvref⟩Ωm≈-0.60054, 20

giving a relative error of ≈0.01%.

Conclusions

In this paper, we have presented some numerical results that describe the fluid flow in an entire lymph node. The scope of the paper was to couple the subcapsular sinus (free fluid region) with the model for the lymphoid compartment (porous bulk region) (Girelli et al 2023) in a geometry more similar to a real lymph node to study in more detail the fluid flow inside the whole system. For this purpose, we have performed numerical simulations to study the behavior of the lymph inside the lymph node in different cases. In Sects. 2 and 3 we have studied the fluid flow using the Stokes equation in the subcapsular sinus (free-fluid region) and the model found in Girelli et al (2023) for the porous bulk region (lymphoid compartment). In particular, we have used two different geometries: the simplified spherical geometry to compare the results with the analytical founding in Girelli et al (2023), and an oblate spheroidal geometry, which is more realistic to describe the lymph node (Jafarnejad et al 2015; O’Melia et al 2019; Tretiakova et al 2021; Giantesio et al 2021; Birmingham et al 2020; Shanti et al 2020) and to see the impact in using different geometries.

We have compared the results found in this paper with both data and findings available in the lymph node literature, and we have found that our results are in line with these data. Thanks to these simulations, we can study the lymph inside the lymph node in a more general and realistic geometry, and this affects the fluid behavior inside the node.

From these simulations, we were able to confirm that, even though the pressure in the blood vessels is higher than the interstitial pressure within the node, lymph flows from the node into the bloodstream. This happens because the blood vessels have a higher protein concentration with respect to the lymph. In our model, this behavior is represented by a sink term in the LC of the node, as we have shown in different plots of the solution. This sink term contributes to the motion of lymph within the lymph node along with the pressure gradient generated by the movement of lymph within the SCS, thereby creating an intermediate situation between these two phenomena, regulated by the microscale interfacial properties between blood vessels and lymph. This clearly shows that the multiscale properties of the lymph node are highly significant. Furthermore, it seems that this phenomenon occurring within the lymph node has been crucial for the balance and regulation of fluid within the lymphatic system. Indeed, damage or removal of lymph nodes leads to a situation called lymphœdema, which is connected to an impairment of lymphatic transport (Moore Jr and Bertram 2018; Tobbia et al 2009). Finally, understanding the biophysical forces and the lymph movement inside the node can help in understanding the immune and drug transport in the whole lymphatic system (Arasa et al 2021; O’Melia et al 2019; Birmingham et al 2020; Shanti et al 2020). In particular, a non-functioning lymphatic system can lead to a severe increase in the interstitial pressure which can in turn impair blood and drug convection within biological systems affected by cancer diseases, see, e.g., Jain et al (2007).

The current work is open for improvements. First, we can take into account the time behavior of the lymph inside the node, so that we can impose a pulsatile inlet condition for the velocity to mimic the lymphangion contraction (Girelli et al 2024). Moreover, it could be interesting to couple the fluid flow motion in the lymphangion and the lymph node together.

A very interesting extension of this model would be to incorporate the temporal and spatial dependence of protein and drug concentrations within the node, in both the FRC and the blood vessels network, to allow a more detailed description of the fluid exchange between these two phases (Penta et al 2015).

We simplified the model presented in Girelli et al (2023) by assuming that multiscale forces were both zero; such forces can play a significant role, especially when utilizing electromagnetic fields (for example in cancer hyperthermia, see Penta 2022; Al Sariri et al 2023). Therefore, it is essential to consider the influence of inhomogeneous volume loads when we get access to physiological data, as outlined in Penta et al (2020).

To simplify the model and address the scarcity of relevant biological data, we employed a rigid porous matrix in this study. However, a possible improvement for this model in the future could involve integrating a deformable matrix that interacts with the lymph flow within the node.

Finally, we opted for an ellipsoidal shape (Jafarnejad et al 2015; Cooper et al 2016, 2018; Giantesio et al 2021; Tretiakova et al 2021; O’Melia et al 2019; Shanti et al 2020). Acquiring more precise data on the lymph node morphology, potentially through the use of medical imaging techniques, could facilitate the refinement of our modeling approach, enabling us to numerically compute macroscopic solutions. This advancement would empower us to generate meaningful physiological predictions in the future.

Acknowledgements

All Authors conducted the research according to the inspiring scientific principles of the national Italian mathematics association Indam (“Istituto nazionale di Alta Matematica”), GNFM group.

Author contributions

Alberto Girelli: Writing-original draft, writing-review and editing, conceptualisation, formal analysis, software, visualisation. Giulia Giantesio: Writing-review and editing, writing-original draft, conceptualisation, software, methodology, supervision. Alessandro Musesti: Writing-review and editing, writing-original draft, conceptualisation, software, methodology, supervision. Raimondo Penta: Writing-review and editing, writing-original draft, conceptualisation, software, methodology, supervision, project administration.

Funding

RP is partially supported by EPSRC grants EP/S030875/1 and EP/T017899/1. Project funded by the EuropeanUnion - NextGenerationEU under the National Recovery and Resilience Plan (NRRP), Mission 4 Component 2 Investment 1.1 - Call PRIN 2022 No. 104 of February 2, 2022 of Italian Ministry of University and Research; Project 202249PF73 (subject area: PE - Physical Sciences and Engineering) "Mathematical models for viscoelastic biological matter".

Data availability and materials

Not applicable.

Declarations

Conflict of interest

The authors have no Conflict of interest as defined by Springer, or other interests that might be perceived to influence the results and/or discussion reported in this paper.

Ethical approval

Not applicable.

Footnotes

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  1. Adair TH, Guyton AC (1983) Modification of lymph by lymph nodes. II. Effect of increased lymph node venous blood pressure. Am J Physiol-Heart Circ Physiol 245(4):H616–H622. 10.1152/ajpheart.1983.245.4.H616 [DOI] [PubMed]
  2. Adair TH, Guyton AC (1985) Modification of lymph by lymph nodes. III. Effect of increased lymph hydrostatic pressure. Am J Physiol-Heart Circ Physiol 249(4):H777–H782. 10.1152/ajpheart.1985.249.4.H777 [DOI] [PubMed]
  3. Adair TH, Moffatt DS, Paulsen AW et al (1982) Quantitation of changes in lymph protein concentration during lymph node transit. Am J Physiol Heart Circ Physiol 243(3):H351–H359. 10.1152/ajpheart.1982.243.3.H351 [DOI] [PubMed] [Google Scholar]
  4. Al Sariri T, Penta R (2022) Multi-scale modelling of nanoparticle delivery and heat transport in vascularised tumours. Math Med Biol: J IMA 39(4):332–367. 10.1093/imammb/dqac009 [DOI] [PubMed] [Google Scholar]
  5. Al Sariri T, Simitev RD, Penta R (2023) Optimal heat transport induced by magnetic nanoparticle delivery in vascularised tumours. J Theor Biol 561:111372. 10.1016/j.jtbi.2022.111372 [DOI] [PubMed] [Google Scholar]
  6. Apoorva F, Loiben AM, Shah SB et al (2018) How biophysical forces regulate human B cell lymphomas. Cell Rep 23(2):499–511. 10.1016/j.celrep.2018.03.069 [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Arasa J, Collado-Diaz V, Halin C (2021) Structure and immune function of afferent lymphatics and their mechanistic contribution to dendritic cell and T cell trafficking. Cells 10(5):1269. 10.3390/cells10051269 [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Auriault JL (2010) About the Beavers and Joseph boundary condition. Transport Porous Media 83:257–266. 10.1007/s11242-009-9435-9 [Google Scholar]
  9. Auriault JL, Boutin C, Geindreau C (2009) Homogenization of coupled phenomena in heterogenous media. Wiley, France [Google Scholar]
  10. Beavers GS, Joseph DD (1967) Boundary conditions at a naturally permeable wall. J Fluid Mech 30(1):197–207. 10.1017/S0022112067001375 [Google Scholar]
  11. Bertram CD, Macaskill C, Davis MJ et al (2017) Valve-related modes of pump failure in collecting lymphatics: numerical and experimental investigation. Biomech Model Mechanobiol 16(6):1987–2003. 10.1007/s10237-017-0933-3 [DOI] [PMC free article] [PubMed] [Google Scholar]
  12. Birmingham KG, O’Melia MJ, Bordy S et al (2020) Lymph node subcapsular sinus microenvironment-on-a-chip modeling shear flow relevant to lymphatic metastasis and immune cell homing. Iscience 23(11):101751. 10.1016/j.isci.2020.101751 [DOI] [PMC free article] [PubMed] [Google Scholar]
  13. Blatter C, Meijer EF, Nam AS et al (2016) In vivo label-free measurement of lymph flow velocity and volumetric flow rates using Doppler optical coherence tomography. Sci Rep 6(1):1–10. 10.1038/srep29035 [DOI] [PMC free article] [PubMed] [Google Scholar]
  14. Bouta EM, Wood RW, Brown EB et al (2014) In vivo quantification of lymph viscosity and pressure in lymphatic vessels and draining lymph nodes of arthritic joints in mice. J Physiol 592(6):1213–1223. 10.1113/jphysiol.2013.266700 [DOI] [PMC free article] [PubMed] [Google Scholar]
  15. Brinkman H (1949) A calculation of the viscous force exerted by a flowing fluid on a dense swarm of particles. Appl Sci Res A1(27):27–34. 10.1007/BF02120313 [Google Scholar]
  16. Carman PC (1997) Fluid flow through granular beds. Chem Eng Res Des 75:S32–S48. 10.1016/S0263-8762(97)80003-2 [Google Scholar]
  17. Carrasco YR, Facundo DB (2007) B cells acquire particulate antigen in a macrophage-rich area at the boundary between the follicle and the subcapsular sinus of the lymph node. Immunity 27:160–171. 10.1016/j.immuni.2007.06.007 [DOI] [PubMed] [Google Scholar]
  18. Chary SR, Jain RK (1989) Direct measurement of interstitial convection and diffusion of albumin in normal and neoplastic tissues by fluorescence photobleaching. Proc Natl Acad Sci 86(14):5385–5389. 10.1073/pnas.86.14.5385 [DOI] [PMC free article] [PubMed] [Google Scholar]
  19. Cooper LJ, Heppell JP, Clough GF et al (2016) An image-based model of fluid flow through lymph nodes. Bull Math Biol 78(1):52–71. 10.1007/s11538-015-0128-y [DOI] [PubMed] [Google Scholar]
  20. Cooper LJ, Zeller-Plumhoff B, Clough GF et al (2018) Using high resolution X-ray computed tomography to create an image based model of a lymph node. J Theor Biol 449:73–82. 10.1016/j.jtbi.2018.04.021 [DOI] [PubMed] [Google Scholar]
  21. Dafni H, Israely ZMB, Benjamin LE et al (2002) Overexpression of vascular endothelial growth factor 165 drives peritumor interstitial convection and induces lymphatic drain: Magnetic resonance imaging, confocal microscopy, and histological tracking of triple-labeled albumin. Can Res 62(22):6731–6739 [PubMed] [Google Scholar]
  22. Discacciati M, Quarteroni A (2009) Navier-Stokes/Darcy coupling: modeling, analysis, and numerical approximation. Revista Matemática Complutense 22(2):315–426. 10.5209/rev_REMA.2009.v22.n2.16263 [Google Scholar]
  23. Eggenweiler E, Rybak I (2021) Effective coupling conditions for arbitrary flows in Stokes–darcy systems. SIAM Multiscale Model Simul 19(2). 10.48550/arXiv.2006.12096
  24. Formaggia L, Quarteroni A, Veneziani A (2009) Cardiovascular mathematics: modeling and simulation of the circulatory system. Springer-Verlag, Milano [Google Scholar]
  25. Gerisch A, Penta R, Lang J (2018) Multiscale models in mechano and tumor biology. Springer, Switzerland [Google Scholar]
  26. Giantesio G, Girelli A, Musesti A (2021) A model of the pulsatile fluid flow in the lymph node. Mech Res Commun 116:103743. 10.1016/j.mechrescom.2021.103743 [Google Scholar]
  27. Giantesio G, Girelli A, Musesti A (2022) A mathematical description of the flow in a spherical lymph node. Bull Math Biol 84:142. 10.1007/s11538-022-01103-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
  28. Girelli A, Giantesio G, Musesti A, and Penta R (2023) Effective governing equations for dual porosity Darcy–Brinkman systems subjected to inhomogeneous body forces and their application to the lymph node. Proc R Soc A 479(2276):20230137. 10.1098/rspa.2023.0137 [Google Scholar]
  29. Girelli A, Giantesio G, Musesti A, and Penta R (2024) Multiscale homogenization for dual porosity time-dependent Darcy-Brinkman/Darcy coupling and its application to the lymph node. Royal Soc Open Sci 11:7 [DOI] [PMC free article] [PubMed] [Google Scholar]
  30. Grebennikov D, Van Loon R, Novkovic M et al (2016) Critical issues in modelling lymph node physiology. Computation 5(1):3. 10.3390/computation5010003 [Google Scholar]
  31. Hornung U (1997) Homogenization and porous media. Springer, New York [Google Scholar]
  32. Irons L, Collis J, O’Dea R (2017) Chapter 12 - microstructural influences on growth and transport in biological tissue-a multiscale description. In: Becker SM (ed) Modeling of Microscale Transport in Biological Processes. Academic Press, p 311–334, 10.1016/B978-0-12-804595-4.00012-2
  33. Jafarnejad M, Woodruff MC, Zawieja DC et al (2015) Modeling lymph flow and fluid exchange with blood vessels in lymph nodes. Lymphat Res Biol 13(4):234–247. 10.1089/lrb.2015.0028 [DOI] [PMC free article] [PubMed] [Google Scholar]
  34. Jafarnejad M, Ismail AZ, Duarte D et al (2019) Quantification of the whole lymph node vasculature based on tomography of the vessel corrosion casts. Nat Sci Rep 9:13380. 10.1038/s41598-019-49055-7 [DOI] [PMC free article] [PubMed] [Google Scholar]
  35. Jäger W, Mikelić A (2000) On the interface boundary condition of Beavers, Joseph, and Saffman. SIAM J Appl Math 60(4):1111–1127. 10.1137/S003613999833678X [Google Scholar]
  36. Jäger W, Mikelić A (2009) Modeling effective interface laws for transport phenomena between an unconfined fluid and a porous medium using homogenization. Transp Porous Media 78:489–508. 10.1007/s11242-009-9354-9 [Google Scholar]
  37. Jain RK, Tong RT, Munn LL (2007) Effect of vascular normalization by antiangiogenic therapy on interstitial hypertension, peritumor edema, and lymphatic metastasis: insights from a mathematical model. Can Res 67(6):2729–2735 [DOI] [PMC free article] [PubMed] [Google Scholar]
  38. Jayathungage Don TD, Safaei S, Maso Talou GD et al (2023) Computational fluid dynamic modeling of the lymphatic system: a review of existing models and future directions. Biomech Model Mechanobiol. 10.1007/s10237-023-01780-9 [DOI] [PMC free article] [PubMed] [Google Scholar]
  39. Johnson C (1987) Numerical solution of partial differential equations by the finite element method. Cambridge University Press, Cambridge [Google Scholar]
  40. Kelch ID, Bogle G, Sands GB et al (2015) Organ-wide 3D-imaging and topological analysis of the continuous microvascular network in a murine lymph node. Nat Sci Rep 16(5):16534. 10.1038/srep16534 [DOI] [PMC free article] [PubMed] [Google Scholar]
  41. Kozeny J (1927) Über kapillare leitung des wassers im boden. Sitzungsber Akad Wiss 136(2a):271–306 [Google Scholar]
  42. Margaris KN, Black RA (2012) Modelling the lymphatic system: challenges and opportunities. J R Soc Interface 9(69):601–612. 10.1098/rsif.2011.0751 [DOI] [PMC free article] [PubMed] [Google Scholar]
  43. Moore JE Jr, Bertram CD (2018) Lymphatic system flows. Annu Rev Fluid Mech 50:459–482. 10.1146/annurev-fluid-122316-045259 [DOI] [PMC free article] [PubMed] [Google Scholar]
  44. Novkovic M, Onder L, Cheng HW et al (2018) Integrative computational modeling of the lymph node stromal cell landscape. Front Immunol 9:2428. 10.3389/fimmu.2018.02428 [DOI] [PMC free article] [PubMed] [Google Scholar]
  45. Novkovic M, Onder L, Bocharov G et al (2020) Topological structure and robustness of the lymph node conduit system. Cell Rep 30(3):893–904. 10.1016/j.celrep.2019.12.070 [DOI] [PubMed] [Google Scholar]
  46. Ochoa-Tapia JA, Whitaker S (1995a) Momentum transfer at the boundary between a porous medium and a homogeneous fluid I. Theoretical development. Int J Heat Mass Transfer 38(14):2635–2646. 10.1016/0017-9310(94)00346-W
  47. Ochoa-Tapia JA, Whitaker S (1995b) Momentum transfer at the boundary between a porous medium and a homogeneous fluid II. Comparison with experiment. Int J Heat Mass Transfer 38(14):2647–2655. 10.1016/0017-9310(94)00347-X
  48. Ohtani O, Ohtani Y (2008) Structure and function of rat lymph nodes. Arch Histol Cytol 71(2):69–76. 10.1679/aohc.71.69 [DOI] [PubMed] [Google Scholar]
  49. O’Melia MJ, Lund AW, Thomas SN (2019) The biophysics of lymphatic transport: engineering tools and immunological consequences. Iscience 22:28–43. 10.1016/j.isci.2019.11.005 [DOI] [PMC free article] [PubMed] [Google Scholar]
  50. Penta R, Ambrosi D, Quarteroni A (2015) Multiscale homogenization for fluid and drug transport in vascularized malignant tissues. Math Models Methods Appl Sci 25(1):79–108. 10.1142/S0218202515500037 [Google Scholar]
  51. Penta R, Ramírez-Torres AD, Merodio J et al (2020) Effective governing equations for heterogenous porous media subject to inhomogeneous body forces. Math Eng 3(4):1–17. 10.3934/mine.2021033 [Google Scholar]
  52. Permana AD, Nainu F, Moffatt K et al (2021) Recent advances in combination of microneedles and nanomedicines for lymphatic targeted drug delivery. Wiley interdisciplinary reviews: nanomedicine and nanobiotechnology 13(3):e1690. 10.1002/wnan.1690 [DOI] [PubMed] [Google Scholar]
  53. Quarteroni A, Valli A (1994) Numerical approximation of partial differential equations. Springer, Heidelberg [Google Scholar]
  54. Quarteroni A, Sacco R, Saleri F (2007) Numerical mathematics. Springer, Heidelberg [Google Scholar]
  55. Saffman PG (1971) On the boundary condition at the surface of a porous medium. Stud Appl Math 50(2):93–101. 10.1002/sapm197150293 [Google Scholar]
  56. Savinkov R, Kislitsyn A, Watson DJ et al (2017) Data-driven modelling of the FRC network for studying the fluid flow in the conduit system. Eng Appl Artif Intell 62:341–349. 10.1016/j.engappai.2016.10.007 [Google Scholar]
  57. Setukha A, Tretiakova R (2022) Computational modeling of lymph filtration and absorption in the lymph node by boundary integral equations. Algorithms 15(10):388. 10.3390/a15100388 [Google Scholar]
  58. Shanti A, Teo J, Stefanini C (2018) In vitro immune organs-on-chip for drug development: a review. Pharmaceutics 10(4):278. 10.3390/pharmaceutics10040278 [DOI] [PMC free article] [PubMed] [Google Scholar]
  59. Shanti A, Samara B, Abdullah A et al (2020) Multi-compartment 3D-cultured organ-on-a-chip: towards a biomimetic lymph node for drug development. Pharmaceutics 12(5):464. 10.3390/pharmaceutics12050464 [DOI] [PMC free article] [PubMed] [Google Scholar]
  60. Shipley RJ, Chapman SJ (2010) Multiscale modelling of fluid and drug transport in vascular tumours. Bull Math Biol 72:1464–1491. 10.1007/s11538-010-9504-9 [DOI] [PubMed] [Google Scholar]
  61. Stohrer M, Boucher Y, Stangassinger M et al (2000) Oncotic pressure in solid tumors is elevated. Can Res 60:4251–4255 [PubMed] [Google Scholar]
  62. Tan H, Pillai KM (2009) Finite element implementation of stress-jump and stress-continuity conditions at porous-medium, clear-fluid interface. Comput Fluids 38(6):1118–1131. 10.1016/j.compfluid.2008.11.006 [Google Scholar]
  63. Tobbia D, Semple J, Baker A et al (2009) Lymphedema development and lymphatic function following lymph node excision in sheep. J Vasc Res 46(5):426–434. 10.1159/000194273 [DOI] [PubMed] [Google Scholar]
  64. Tomei AA, Siegert S, Britschgi MR et al (2009) Fluid flow regulates stromal cell organization and CCL21 expression in a tissue-engineered lymph node microenvironment. J Immunol 183(7):4273–4283. 10.4049/jimmunol.0900835 [DOI] [PubMed] [Google Scholar]
  65. Tretiakova R, Setukha A, Savinkov R et al (2021) Mathematical modeling of lymph node drainage function by neural network. Mathematics 9(23):3093. 10.3390/math9233093 [Google Scholar]
  66. Waniewski J (2006) Mathematical modeling of fluid and solute transport in hemodialysis and peritoneal dialysis. J Membr Sci 274:24–37. 10.1016/j.memsci.2005.11.038 [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

Not applicable.


Articles from Biomechanics and Modeling in Mechanobiology are provided here courtesy of Springer