Skip to main content
Biochemical Journal logoLink to Biochemical Journal
. 1982 Sep 1;205(3):639–641. doi: 10.1042/bj2050639

A simple test for macromolecular heterogeneity in the analytical ultracentrifuge

J Michael Creeth *, Stephen E Harding
PMCID: PMC1158533  PMID: 7150237

Abstract

A simple check for the presence of heterogeneity in a macromolecular system is proposed, employing comparison of Rayleigh sedimentation-equilibrium patterns for two solutions of the same fringe concentration but differing absolute concentrations. The method is illustrated by application to a bronchial glycoprotein from a cystic-fibrosis patient.

Full text

PDF

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Gilbert G. A., Gilbert L. M. Detection in the ultracentrifuge of protein heterogeneity by computer modelling, illustrated by pyruvate dehydrogenase multienzyme complex. J Mol Biol. 1980 Dec 15;144(3):405–408. doi: 10.1016/0022-2836(80)90099-6. [DOI] [PubMed] [Google Scholar]
  2. Teller D. C. Characterization of proteins by sedimentation equilibrium in the analytical ultracentrifuge. Methods Enzymol. 1973;27:346–441. doi: 10.1016/s0076-6879(73)27017-9. [DOI] [PubMed] [Google Scholar]
  3. YPHANTIS D. A. EQUILIBRIUM ULTRACENTRIFUGATION OF DILUTE SOLUTIONS. Biochemistry. 1964 Mar;3:297–317. doi: 10.1021/bi00891a003. [DOI] [PubMed] [Google Scholar]

Articles from Biochemical Journal are provided here courtesy of The Biochemical Society

RESOURCES