Skip to main content
Data in Brief logoLink to Data in Brief
. 2024 Nov 8;57:111099. doi: 10.1016/j.dib.2024.111099

Analytical data on three Martian simulants

Nicole Costa a,d,, Alessandro Bonetto b, Patrizia Ferretti b, Bruno Casarotto a, Matteo Massironi a,b,c, Francesca Altieri d, Jacopo Nava a, Marco Favero a
PMCID: PMC11615520  PMID: 39633971

Abstract

The preparation of planetary missions as well as the analysis of their data require a wide use of planetary simulants. They are very important for both testing mission operations and payloads, and for interpreting remote sensing data. In this work, a detailed analysis of three commercially available simulants of Martian dust and regolith is presented. Indeed, up to date, a complete data set related to their chemical, mineralogical, granulometric and spectral characters is not fully provided by their distribution and sales companies. Our dataset regards the Mars Global (MGS-1) High-Fidelity Martian Dirt Simulant [1], the Mojave Mars Simulant MMS-1 [2] and the Enhanced Mars Simulant (MMS-2) [2]. Being essential for ensuring consistency and enabling data comparison, all the chosen Martian simulants underwent the same analytical process. Grainsize data were collected using a Laser Diffraction Particle Size Analyzer. Chemical analysis was performed by Inductively Coupled Plasma Mass Spectroscopy (ICP-MS). Mineralogical analysis was carried out by X-Ray powder Diffractometry (XRD). Moreover, the largest particles of MGS-1 simulant were analyzed with the Scanning Electron Microscope (SEM-EDS) in order to confirm their chemical composition. Finally, the spectral acquisitions in the VNIR-SWIR range were taken by two Headwall Photonics hyperspectral imaging cameras. This complete series of data integrating pre-existing ones (e.g., Cannon et al. [1] and Karl et al. [2]) can in the future be used to allow a straightful choice of the right simulant for biological and life-support experiments and potential testing of mission instruments, to help inferring the composition of the Martian surface from remote sensing data, and to create new simulants or adjust the existing ones in order to get closer to the known Martian regolith variability and eventually new compositional information provided by future missions.

Keywords: MARS, Mass-spectrometer, XR-diffraction, SEM, Grainsize, Hyperspectral, VNIR, SWIR


Specifications Table

Subject Space and Planetary Science
Specific subject area Planetary geology; Mars geology; Mars soil simulants
Type of data Tables, Images, Graphs
.docx file
Raw, analyzed
Data collection This dataset contains data derived from chemical, mineralogical, granulometric and hyperspectral acquisitions of Mars Global (MGS-1) High-Fidelity Martian Dirt Simulant [1], Mojave Mars Simulant MMS-1 [2,3] and Enhanced Mars Simulant (MMS-2) [2,4]. The instruments used for this work are:
  • -

    Laser Diffraction Particle Size Analyzer Malvern Panalytical Mastersizer3000: granulometric analysis.

  • -

    Inductively Coupled Plasma Mass Spectrometer (ICP-MS) Perkin-Elmer NexION 350X: chemical analysis.

  • -

    X-Ray powder Diffractometer (XRD) Philips X'Pert PRO: mineralogical analysis.

  • -

    Scanning Electron Microscope (SEM-EDS) Tescan SOLARIS equipped with Oxford Instruments microanalytical system: chemical analysis.

  • -

    Headwall Photonics Nano-Hyperspec (400–1000 nm) and Micro-Hyperspec (900–2500 nm) cameras: reflectance measurements.

Data source location Dipartimento di Geoscienze, Università degli Studi di Padova, Padova, Italia (45°24′33.61″ N; 11°53′37.30″ E)
Data accessibility Repository name: MartianSimulants
Data identification number: 10.25430/researchdata.cab.unipd.it.00001279
Direct URL to data: https://researchdata.cab.unipd.it/id/eprint/1279

1. Value of the Data

  • Our analytical dataset provides new granulometric, chemical, mineralogical and hyperspectral data of three commercially available simulants of Martian regolith carried out using the same instruments and procedures. This approach ensures consistency of data and allows for better comparison of the different variables.

  • The dataset constitutes a deep characterization of Martian regolith and dust, useful for any studies aimed to unravel whether Mars soils can support plant growth by means of microbiological and plant cultivation experiments in Mars analogue environments.

  • These data could be used for any interpretation of the Mars surface composition from orbital acquisition through a comparison with reference samples of well-known chemical, mineralogical and spectral properties.

2. Background

Planetary simulants are of paramount importance as reference material to infer planetary surface composition from orbital remote sensing data, biological and life-support experiments, testing planetary missions’ payloads, setting up planetary analogue facilities for in situ mission operations. Hence their physical properties as well as their mineralogical and chemical composition must be fully constrained. Nonetheless the commercially available simulants are often accompanied by partial descriptions, acceptable for some applications but not sufficient when detailed characterizations are needed to understand planetary surface compositions. In addition, different sales and distribution companies characterize their samples using different instruments and approaches and thus making less straightforward their comparison. Finally, slight variability of compositional properties of commercially available samples have been documented (e.g., [6]), hence a periodic full characterization is extremely beneficial even considering the continuous technological improvement of the laboratory devices and their analytical capabilities. In this work we have characterized different global and commercially available simulants of the Martian regolith and atmospheric dust. They are indeed particularly relevant for life support experiments in analogue environments and the understanding, from remote sensing data, of the variable dust cover on the Martian surface as well as of the content, grain size and composition of dust-ice intermixing in its polar caps.

3. Data Description

This article collects an analytical dataset of the following commercial simulants: the Mars Global High-Fidelity Martian Dirt Simulant (MGS-1), reproducing the average composition of the Red Planet [1], the Mojave Mars Simulant (MMS-1) [3] and the Enhanced Mojave Mars Regolith Simulant (MMS-2) [4] both simulating the regolith composition found by the lander Phoenix which landed at the edge of the North Polar Cap, in the region named Green Valley [5]. However, MMS-1 comes from altered pyroclasts of a cinder cone close to MMS site but not from the original Saddleback basalt of MMS [2,5]. MMS-2 derives from the MMS-1 simulant enhanced with iron and magnesium oxides, silica sand and gypsum to mimic the Opportunity soil measurements [5] and pretending to be representative of the average Martian surface. The bulk composition of the three simulants provided by the sales companies is reported in the following Table 1 and compared with the Martian average composition obtained through NASA Curiosity rover in Gale Crater (Rocknest soil [1,7]) and through NASA lander Phoenix in Green Valley [2].

Table 1.

Table of elemental composition in weight percentage (wt%) of the chosen simulants. The oxides content of the Martian simulants is compared with oxide content taken in specific reference sites on Mars for each simulant.

Oxide (wt%) Mars average MGS-1 Mars average MMS-1 MMS-2
Reference [1,7] [8] [9] [9] [9]
SiO2 42.97 43.90 43.52 49.40 43.8
TiO2 1.19 0.46 0.78 1.09 0.83
Al2O3 9.37 12.84 8.64 17.10 13.07
Cr2O3 0.49 0.37 0.05 0.04
Fe2O3 19.18 10.60 18.28 10.87 18.37
MnO 0.42 0.11 0.32 0.17 0.13
MgO 8.69 14.81 6.54 6.08 6.66
CaO 7.26 7.91 6.09 10.45 7.98
Na2O 2.70 1.49 2.57 3.28 2.51
K2O 0.49 0.29 0.35 0.48 0.37
P2O5 0.95 0.17 0.79 0.17 0.13
SO3 5.47 6.42 0.10 6.11

It is worth comparing this data-set with our results which represent a substantial integration of the pre-existing data-set. Indeed, in the following sections together with the chemical data obtained through Inductively Coupled Plasma Mass Spectrosmetry we provide granulometric information using a Laser Diffraction Particle Sizer Analyzer, the mineralogic characterization through X-ray Diffraction and the hyperspectral signatures obtained using hyperspectral imaging cameras.

The dataset of our analysis is contained in the linked repository in Research Data Unipd [10] and it is composed of a single folder named “MartianSimulants”. The folder includes five sub-folders, each one for every instrument used for the characterization. The sub-folders are designated with the instrument name: 1) “granulometer” for the particle size analyzer; 2) “ICP-MS” for the ICP-mass spectrometer; 3) “powderXRD” for the X-ray diffractometer; 4) “SEM-EDS” for the scanning electron microscope; 5) “hyperspectralcameras” for the cameras. In each sub-folder, there are three .pfd files named like the simulants: 1) MGS-1; 2) MMS-1; 3) MMS-2.

In particular, the sub-folder “granulometer” files are named like the simulant: “MGS-1.docx”, “MMS-1.docx” and “MMS-2.docx”. The .docx file includes graph of the grainsizes (Fig. 1) and the related table (Table 2). The diagram in Fig. 1 highlights the grainsize distribution of five acquisitions and their average for the original sample and five different granulometric classes, in which the simulant was sieved (0–32 µm, 32–63 µm, 63–250 µm, 250–1000 µm and >1000 µm). With the term Original sample, we refer to the simulant powder as it was received in the original package. The table reports the five-acquisition data and their average for every class and for the original sample (Table 2).

Fig. 1.

Fig 1

Granulometric curves of the original MGS-1.

Table 2.

Extract of the table derived from granulometric analysis of the original MGS-1.

Size classes (µm) Measure n#1 Measure n#2 Measure n#3 Measure n#4 Measure n#5 Average measure
0,1061 0,000 0,000 0,000 0,000 0,000 0,000
0,1205 0,000 0,000 0,000 0,000 0,000 0,000
0,1369 0,000 0,000 0,000 0,000 0,000 0,000
0,1556 0,000 0,000 0,000 0,000 0,000 0,000
0,1768 0,000 0,000 0,000 0,000 0,000 0,000
0,2008 0,000 0,000 0,000 0,000 0,000 0,000
0,2282 0,000 0,000 0,000 0,000 0,000 0,000
0,2593 0,000 0,000 0,000 0,000 0,000 0,000
0,2946 0,000 0,000 0,000 0,000 0,000 0,000
0,3347 0,000 0,000 0,000 0,000 0,000 0,000
0,3802 0,000 0,000 0,000 0,000 0,000 0,000
0,4320 0,000 0,000 0,000 0,000 0,000 0,000
0,4908 0,000 0,000 0,000 0,000 0,000 0,000
0,5577 0,008 0,008 0,008 0,008 0,008 0,008
0,6336 0,083 0,084 0,082 0,083 0,082 0,083
0,7199 0,125 0,124 0,124 0,123 0,123 0,124
0,8179 0,162 0,159 0,161 0,158 0,158 0,160

In the sub-folder “ICP-MS,” the file “MGS-1, MMS-1, MMS-2.docx” contains the concentrations of the major and minor elements measured in the three Martian simulants (expressed in mg/g for major elements and µg/g for minor elements) together with their relative standard deviation in percent (RSD%; Table 3). Note that Cadmium-111 concentration was not provided because under the detection limit of the instrument.

Table 3.

Concentrations of chemical elements and their relative standard deviations in percent (RSD%) for MGS-1, MMS-1 and MMS-2.

Units mg/gr
µg/gr
Chemical element Al 27 Na 23 Mg 24 Ti 47 K 39 Ca 43 Fe 57 Cr 52 V 51 Co 59 Ni 60 Mn 55 Sr 88 Cd 111 Cu 63 Zn 68 Ba 137 Be 9 Pb 208 Tl 205
MGS-1 value 23 988 46 3,8 5,5 49 88 747 90 47 557 852 245 N.D. 14 131 154 0,35 0,29 0,41
RSD% 4,1 3,5 4,4 0,9 1,6 7,3 0,4 6,0 0,7 3,4 1,0 2,0 2,7 17,8 30,2 4,6 10,3 95,6 3,7
MMS-1 value 78 1920 20 5,4 20 48 55 113 72 23 74 954 304 N.D. 31 155 622 1,6 7,9 0,6
RSD% 1,1 1,0 1,8 4,3 0,9 9,9 1,1 2,1 2,9 5,0 2,0 1,9 2,3 2,8 7,5 1,8 16,5 2,1 6,8
MMS-2 value 64 1535 28 4,3 17 46 95 88 56 19 64 1149 319 N.D. 38 120 554 1,4 7,7 0,5
RSD% 1,4 1,3 0,4 2,8 1,2 12,3 0,2 4,9 1,6 4,3 1,6 1,6 1,7 1,4 22,7 1,0 13,6 4,9 15,0

The three files in the sub-folder “powderXRD” are named with the simulant names (e.g., “MGS-1.docx”). In each file there are two diffractograms and related tables: the first one is related to a qualitative analysis excluding the amorphous material (Fig. 2a and Table 4a), the second one to a quantitative analysis which however includes the amorphous material (Fig. 2b and Table 4b). Therefore, the first table includes the minerals revealed in the sample (Table 4a), while in the second table the identified minerals are accompanied with their amount in percent (%) (Table 4b). Peaks shown in the diffractograms are linked to specific minerals (Fig. 2a and b). In the database, we also added the diffraction patterns in numerical format.

Fig. 2.

Fig 2

a) XRD pattern related to qualitative analysis of the simulant MGS-1; b) XRD pattern related to quantitative analysis of the simulant MGS-1: minerals detected are shown in different colors. The gray curve at the bottom represents the differences, in terms of intensities, between the measured (black) pattern and the fitted (red) pattern, it shows effectively the goodness of the fit.

Table 4.

a) Table of qualitative analysis of the simulant MGS-1; b) Table of quantitative analysis in mass percentage (in m%) of the simulant MGS-1.

A Components
Olivine
Plagioclase
Quartz
Pyroxene
Magnetite
Epsomite
Gypsum
Mica
Chlorite
Talc
siderite
serpentine
hematite
calcite
ferrihydrite
amphibole

B Components Amount (m%)
olivine 12.6
plagioclase 30.1
quartz 1.7
pyroxene 15.8
magnetite 2.1
epsomite 2.2
gypsum 2.9
mica 2.1
chlorite 1.7
talc 3.0
siderite 0.3
serpentine 0.8
hematite 0.7
calcite 0.3
ferrihydrite 4.6
amphibole 1.9
amorphous 17.2

In the sub-folder “SEM-EDS” the file “MGS-1.docx” shows the chemical composition of the coarser grains picked from the MGS-1 simulant. The file contains a photo of the analyzed crystals (Fig. 3a), the pictures in secondary electrons (SE)taken under the scanning electron microscope of the crystals where the spectra were acquired (Fig. 3b) and the spectrum itself and related elemental ratio from the energy-dispersive spectroscopy analysis (Fig. 3c). The spectra show peaks associated with specific chemical elements, that allow us to understand the chemical composition of the grain. Images and spectra are divided between sections “Dark crystals” and “Red crystals” based on the optical color of the minerals, followed by a short mineralogic interpretation of data reported in Table 5.

Fig. 3.

Fig 3

Mineralogical and chemical characterization of the coarser grains of the MGS-1 simulant. a) Pyroxene and gypsum/Al-oxides crystals, corresponding to dark and red samples respectively; b) Secondary Electrons (SE) pictures of the crystal and the sites where the data were collected; c) Back Scattered Electrons (BSE) pictures of the crystal and the sites where data were collected; d) spectrum acquired on the black crystal and related elemental ratio from the energy-dispersive spectroscopy analysis expressed in oxide percentage.

Table 5.

Table of minerals recognized in the crystal analysis of the MGS-1 simulant.

Crystals Detected minerals Minor minerals
Black Pyroxene Phyllosilicates
Red Gypsum/Al-oxides Gypsum, patina of plagioclase or talc

The three files in the sub-folder “hyperspectralcameras” have the name of each simulant. For example, in the “MGS-1.docx” file there is the spectral plot (Fig. 4) of the data reported in the Table 6. Thanks to the absorption bands in the graph (Fig. 4) we can identify the main spectral features of the simulant and comprehend the minerals existing within the simulant. The table (Table 6) displays the wavelength range (nm) for the original simulant and for the sieved simulant in the following granulometric classes: 0–32 µm, 32–63 µm, 63–250 µm, 250–1000 µm and >1000 µm. For each class, we acquired two spectra, with the only exception of the >1000 µm-class whose limited amount of material did not allow more than one acquisition (see “MMS-2.docx”). Following Zhang et al. [11], the smoothed/ merged data were multiplied by absolute reflectance of the Spectralon white reference [12] in order to mitigate potential artifacts due to its absorption peak at 2100 nm. Raw data as well as Spectralon white reference data [12] are provided in dedicated tables within the database.

Fig. 4.

Fig 4

Spectra of the original (i.e., bulk sample) and different grainsize fractions of MGS-1.

Table 6.

Extract of the table derived from hyperspectral acquisition of the simulant MGS-1.

Wavelengths (nm) original Wavelengths (nm) 0–32 µm 32–63 µm 63–250 µm 250–1000 µm >1000 µm
419,26 0,09,186 399,35 0,19,066 0,20,192 0,2148 0,20,697 0,1787 0,18,712 0,15,049 0,14,403 0,1631 0,16,578
421,48 0,08,853 401,56 0,16,198 0,17,347 0,17,115 0,17,426 0,14,673 0,16,301 0,12,402 0,12,088 0,14,095 0,14,537
423,69 0,08,909 403,77 0,14,084 0,15,737 0,14,392 0,15,231 0,1307 0,14,349 0,1097 0,10,655 0,12,311 0,1309
425,90 0,09,141 405,99 0,13,605 0,14,231 0,13,021 0,13,888 0,12,657 0,13,156 0,09,999 0,09,902 0,1098 0,11,735
428,12 0,09,344 408,20 0,13,132 0,13,272 0,12,441 0,1324 0,12,179 0,12,674 0,08,617 0,0916 0,10,067 0,1044
430,33 0,09,355 410,41 0,11,696 0,12,648 0,11,962 0,1236 0,10,825 0,11,653 0,07,239 0,08,222 0,0912 0,08,962
432,54 0,09,383 412,62 0,10,121 0,12,007 0,11,027 0,11,308 0,09,626 0,10,494 0,06,502 0,07,747 0,08,026 0,07,563
434,76 0,09,592 414,84 0,09,332 0,11,169 0,09,536 0,10,107 0,08,837 0,09,409 0,05,733 0,07,066 0,06,903 0,06,658
436,97 0,09,871 417,05 0,08,892 0,10,143 0,08,453 0,092 0,07,904 0,08,394 0,05,078 0,05,754 0,06,016 0,0617
439,18 0,10,076 419,26 0,08,537 0,09,484 0,08,503 0,09,083 0,07,507 0,08,072 0,04,917 0,04,982 0,05,665 0,05,955
441,40 0,10,278 421,48 0,08,549 0,09,402 0,08,549 0,09,131 0,07,552 0,08,188 0,04,881 0,05,102 0,0562 0,0585
443,61 0,10,485 423,69 0,08,558 0,09,443 0,08,331 0,08,887 0,07,544 0,08,195 0,04,832 0,05,189 0,05,616 0,05,628
445,82 0,10,689 425,90 0,08,549 0,09,122 0,0857 0,08,628 0,07,667 0,07,946 0,04,741 0,04,897 0,05,696 0,05,384
448,04 0,10,882 428,12 0,08,563 0,08,981 0,0893 0,08,565 0,07,862 0,07,744 0,0457 0,04,798 0,05,746 0,05,346
450,25 0,11,055 430,33 0,08,466 0,09,015 0,0894 0,08,466 0,07,803 0,07,405 0,04,136 0,04,619 0,05,635 0,05,212
452,46 0,11,189 432,54 0,08,439 0,09,109 0,08,887 0,08,634 0,0768 0,07,267 0,03,957 0,04,398 0,05,536 0,05,072
454,67 0,11,312 434,76 0,08,559 0,09,616 0,08,977 0,09,165 0,07,987 0,07,762 0,0435 0,04,721 0,05,467 0,05,227
456,89 0,1149 436,97 0,08,739 0,10,155 0,0905 0,09,601 0,08,396 0,08,278 0,0469 0,05,144 0,05,505 0,05,509
459,10 0,11,661 439,18 0,08,812 0,10,189 0,09,064 0,09,587 0,08,381 0,08,463 0,04,677 0,0523 0,0563 0,05,688

4. Experimental Design, Materials and Methods

4.1. Granulometric data

The granulometric analysis has been conducted by means of Laser Diffraction Particle Size Analyzer (Malvern Panalytical Mastersizer3000) equipped with a large volume liquid dispenser (Hydro LV). Samples have been added until a 4 % of light obscuration. Both during the sample addition and the analysis, ultrasound dispersion was activated at the power of 90 %, and the stirring speed has been set to 2500 rpm. In the table below are reported the main parameter for the data acquisition and elaboration (Table 7).

Table 7.

Main parameters of the Mastersizer3000 software set for this acquisition.

Parameter Value
Particle shape Not-spherical
Material Silica
Refractive index 1.46
Adsorption 0.01
Density (g/cm3) 1
Medium Water
Background Only water
Blue light Yes
Number of acquisitions 20
Interval between acquisitions 2 s
Acquisition time 10 s
Obscuration 3–15 %
Shaking 3/4
Ultra-sound Yes
Cleaning cycle Automatic
Data processing General purpose
Grainsize limits 0.1–2000 µm
Results % volume
Grainsize classes Udden-Wentworth

Firstly, we have measured the particle size and size distribution of the original simulants (i.e., the bulk samples). After this first screening, the samples have been sieved with an automated vibrating sieve (Retsch) using the following sieve-ranges: 〈32 µm, 32–63 µm, 63–250 µm, 250–1000 µm, 〉 1000 µm. Each fraction has been characterized through the laser diffraction granulometry. For each acquisition, the last five measurements (of 20) have been averaged and reported in a .jpg file, .txt file, and collected in a .docx file.

4.2. Chemical data (ICP-MS)

The Inductively Coupled Plasma Mass Spectroscopy Perkin-Elmer NexION 350X has been employed for the quantitative analysis of inorganics elements of the simulants. Around 10 mg of sample has been weighted (Practum, Sartorius, 0.01 mg) and inserted in Teflon vessel for the acidic mineralization assisted by microwave (Ethos UP, Milestone). A mixture of 5 ml of Acqua Regia (3:1 HCl:HNO3) and 1 ml of HF has been added to the vessel, and the container has been sealed and microwave heated following the ramp reported in Table 8.

Table 8.

Parameters for the microwave used for the preparation of ICP-MS samples.

Time (s) 15 20
Temperature (°C) 210 210
Cooling 40 min
Program name BCS 300 (Soil)

The digested has been diluted to a final volume of 50 ml with ultrapure water and analyzed with ICP-MS Perkin Elmer Nexion 350X coupled with the autosampler seaFAST (Direct mode, 4 ml, x10). The selected elements reported in Table 9 have been quantified by means an external eleven-point calibration curves that is also reported in Table 9. The instrumental drift has been corrected by using the Rh (103) as internal standard.

Table 9.

Elements selected for the chemical analysis and relative parameters used during the acquisition.

Elements Mass Mode He flux (ml/min) Calibration range (µg/L)
Al 27 KED 4.4 100–1000
Na 23 4.4
Mg 24 4.4
Ti 49 4.4
K 39 4.4
Ca 43 4.4
Fe 57 4.4
Cr 52 4.4 0.5–100
V 51 4.4
Co 59 0.1
Ni 60 4.4
Mn 55 4.4
Sr 88 4.4
Cd 111 4.4
Cu 63 4.4
Zn 68 4.4
Ba 137 4.4
Be 9 0.1
Pb 208 0.1
Tl 205 0.1

For the quality control, “NIST 2711a Montana Soil 2” has been used as Certificate Reference Material (CRM) in order to evaluate the accuracy of the method. The output data are in .txt format as table and converted to a .docx file.

4.3. Mineralogical data (X-ray diffraction)

The X-ray diffractometer Philips X'Pert PRO (Bragg-Brentano HD optics, cobalt source, detector X'Celerator detector) has been used for mineralogical characterization of the three Martian simulants. We have prepared the samples in different ways in function of the analysis to be carried out as follows:

  • -

    Qualitative analysis: manual grinding of dry simulants with agate mortar (<63 µm).

  • -

    Quantitative analysis – Rietveld method: the samples was weighted and mixed with an appropriate amount of standard zincite ZnO in order to be 20 % of the whole sample. A specific amount of ethanol was added to the mixture of MMS-1 + zincite and of MMS-2 + zincite, which was put in the micronizer at highest speed for 5 min. The powder was dried in air. The mixture MGS-1 + zincite was gridded by a dry bead mill because of the solubility of the Mg-sulphate in MGS-1The result was a uniform and fine powder (<5 µm) ready to be analyzed.

HighScore (Plus) software version 4.9 (PANalytical B.V., 2020, Almelo, The Netherlands) [13] allows to identify the mineral species (qualitative phase analysis) while the relative abundance of each phase has been calculated using the Rietveld method as implemented in Profex-BGMN v. 5.2.3 [14]. The plots and the table with minerals and relative amounts are exported as .jpg file and .txt file, respectively, and collected in a .docx file. The following Table 10 summarizes all the information.

Table 10.

Main parameters about the XRD acquisitions.

Instrument Philips X'Pert Pro Diffractometer (Almelo, The Netherlands) working with parafocusing Bragg Brentano geometry
X-ray tube Long Fine Focus, Co source, 40 kV and 40 mA generator settings
Detector Real-Time Multiple Strip (RTMS) X'Celerator
Sample holder Circular, 27 mm diameter and 2 mm thick. Back-loading filling
Accessories Bragg-BrentanoHD ©, spinner for sample revolution on vertical axis
Slits Divergence slits 1/4°, antiscatter slits 1°, Soller silits 0.04 rad
Data acquisition 3–85° 2theta, continous scan lasting 1 h (100 s for 0.017° 2theta virtual steps).
Micronization procedure 5 min grinding using ethanol at 1500 rpm/min. Instrument: Retsch XRD-MILL MCCRONE.
Dry grinding procedure 3 min dry grinding at 20 Hz frequency. Instrument: Retsch MM 400
Qualitative phase analysis HighScore (Plus) software version 4.9, year 2020,
by PANalytical B.V., Almelo, The Netherlands [13]
Quantitative phase analysis Profex-BGMN v.5.2.3 [14]

4.4. Chemical data of MGS-1 (SEM-EDS)

Chemical analyses have been acquired with the dual beam scanning electron microscope FEG-FIB Tescan SOLARIS. The instrument is equipped with the Ultim Max 65 Silicon Drift EDS made by Oxford Instruments. This detector was used to confirm the chemical composition of the mineralogical phases in the MGS-1 coarse black and reddish grains. We worked at 15 KeV, 3 nA with a working distance of 5 mm. The crystals have been coated with Chromium before the analyses to prevent charging. Since only semi-quantitative data were acquired, the samples were not polished and no standardization was needed, we only performed the current calibration of the cobalt standard and then we used an internal standardization in the Aztec software made by Oxford Instruments. The output are highly-detailed photos, in which sites of chemical acquisitions are displayed with the corresponding spectra where each peak is representative of a specific element, from which to infer the mineralogy. Images and diagrams are exported as .jpg file and collected in a .docx file.

4.5. Hyperspectral data

The hyperspectral imaging cameras used are:

  • Headwall Photonics Nano-Hyperspec: push-broom camera, spectral range from 400 to 1000 nm, 270 spectral bands, 640 spatial bands, sampling of ∼2 nm, spatial resolution varying with the height of the camera in its stage;

  • Headwall Photonics Micro-Hyperspec camera: push-broom camera, spectral range from 900 to 2500 nm, 170 spectral bands, 384 spatial bands, sampling of ∼10 nm, spatial resolution varying with the height of the camera in its stage.

The laboratory setup accommodation for hyperspectral acquisitions consists in: a camera holder and a motorized stage of 20 × 20 cm in dimension and capable to sustain up to 20 kg while illumination is equipped by a tiltable halogen lamp provided with a ground glass diffuser. The whole system measures 100 × 45 × 78 cm. After setting up parameters in the camera software, original simulants were placed on the motorized stage to acquire their spectra both in VNIR and SWIR range (Table 11). As white reference for radiance conversion a 99 % reflectivity Spectralon (Labsphere, Inc.) [12] was used, we repeated the acquisition twice with each grainsize-class of the three simulants.

Table 11.

Main parameters of the Headwall photonics nano-hyperspec and micro-hyperspec for this acquisition.

Camera VNIR SWIR
Exposure (ms) 14 10
Frame period (ms) 25 15
Lens EFL (mm) 17 25
Array Pixel Pitch (µm) 7.4 24
Camera FPS 40.13 61.84
Write FPS 40 60
Stage speed (mm/s) 9.1 18
Height (cm) 52.5 28
Spatial pixel size (mm) ∼0.25 ∼0.25

Acquisition output files were imported in ENVI software [15] where Regions of Interest (ROIs) were defined and spectral data extrapolated. The obtained files in ASCII format were opened and processed in Origin software [16]. A light smoothing (binomial method) was applied in the VNIR spectra to reduce signal noise and finally VNIR and SWIR acquisitions were merged at 970 nm. For the sieved simulants, merging consisted in a downward shift of the SWIR curve, while for the original VNIR and SWIR simulants values around the merging point were averaged. Therefore, the original and sieved samples have different x-axis values in the merging region. Moreover, the smoothed/merged data were multiplied by absolute reflectance of the Spectralon white reference [12] to mitigate potentials artifacts [11]. Finally, plots and tables of the spectral acquisitions were exported as a jpg. file and .txt file and collected in a .docx file.

Limitations

Global and commercially available Martian simulants are still few and, among the most accessible ones, MMS-1 and MMS-2 are only partially representative of the global dust [2]. This raises the need to identify or eventually create through appropriate mixtures new and even more realistic natural simulants. Although X-ray diffraction is a very efficient technique, overlapping peaks might leave some margin to different interpretations. For this reason we have provided even the diffraction patterns in a numerical format. The EDS results do not show any peak overlapping being detected only well distinguishable pyroxenes, feldspars and sulphates on major grains of MGS-1 whose composition was already detected through the XRD analysis.

Ethics Statement

All authors have read and followed the ethical requirements for publication in Data in Brief and confirming that the current work has not involved human subjects, animal experiments, or any data collected from social media platforms.

Credit Author Statement

Nicole Costa: Conceptualization, Validation, Formal analysis, Investigation, Data Curation, Writing – Original Draft, Writing – Review & Editing, Alessandro Bonetto: Methodology, Validation, Formal analysis, Investigation, Resources, Data Curation, Writing – Review & Editing, Patrizia Ferretti: Resources, Supervision, Writing – Review & Editing, Bruno Casarotto: Methodology, Validation, Formal analysis, Investigation, Data Curation, Writing – Review & Editing, Matteo Massironi: Resources, Writing – Review & Editing, Supervision, Francesca Altieri: Supervision, Writing – Review & Editing, Jacopo Nava: Validation, Formal analysis, Investigation, Data Curation, Marco Favero: Validation, Formal analysis, Investigation, Data Curation.

Acknowledgments

We thank the editor and the two reviewers for their useful comments that substantially improved the former version of the manuscript. Nicole Costa is funded by the PhD program of the University of Padova, whereas the specific research has been supported by the ASI SPACE IT Up project ASI N. 2024-5-E.0.

Declaration of Competing Interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Data Availability

References

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement


Articles from Data in Brief are provided here courtesy of Elsevier

RESOURCES