Background
Biventricular pacing (BIVP) traditionally delivers cardiac resynchronization therapy (CRT) by using pacing leads in the right ventricle and the coronary sinus.
Cardiac resynchronization therapy is the heart failure (HF) therapy “that simultaneously improves cardiac function and functional capacity, reduces hospitalization, and prolongs survival”1 in patients with HF with a reduced ejection fraction and a wide QRS complex.2-16 Solid randomized clinical trial (RCT) efficacy and safety data in more than 8,500 patients with biventricular devices17,18 have established CRT as the standard therapy in this category of patients. Approximately 20% to 40% of patients, however, do not respond to CRT via BIVP depending on the measure used.17 Up to 7% of biventricular pacemaker implants are furthermore unsuccessful as a result of difficulties encountered while implanting the left ventricular coronary sinus lead.9
For patients with a left ventricular ejection fraction of 36% to 50%, the BLOCK HF trial showed the superiority of BIVP to right ventricular pacing9 for a composite outcome of all-cause mortality, hospitalization as a result of HF, and an increase of more than 15% in the left ventricular end-systolic volume index. Because of higher costs, BIVP is not used often as a first-line therapy over right ventricular pacing outside of the United States.
Recent Developments
Because of the limitations of BIVP, conduction system pacing (CSP) at the level of His bundle19 or the left bundle branch20 has emerged as an alternative physiologic pacing treatment that preserves or restores left ventricular electrical and mechanical synchrony. Left bundle branch area pacing has become the dominant approach because of its higher success rate, lower and more stable pacing thresholds, and its correction of the left bundle branch block below the level of the His bundle compared with His bundle pacing.21
There are only 7 randomized clinical trials comparing His bundle pacing and left bundle branch area pacing with BIVP.21 All of the trials are small, of short duration, and were not powered for major clinical end points such as HF hospitalizations and death. His bundle pacing and left bundle branch area pacing are at least equal or superior to BIVP in terms of surrogate parameters for electrical and mechanical synchrony.
There are substantially more data from large registries and retrospective comparative studies suggesting that His bundle pacing and left bundle branch area pacing may be superior to BIVP in terms of hard outcomes and possibly safety. An analysis of the safety of left bundle branch area pacing from the Multicentre European Left Bundle Branch Area Pacing Outcomes Study (MELOS) demonstrated higher success rates among early European adopters of left bundle branch area pacing when the procedure was performed for bradycardia (92.4%) and HF (82.2%).22 This study reported the highest complication rate (8.3%), though a notable majority of the complications were clinically insignificant septal perforations.
The largest retrospective case-control study, I-CLAS, suggested that left bundle branch area pacing outperformed BIVP and was associated with reduction in time to death and HF hospitalizations.21 Similar results were reported by 2 additional retrospective studies.23,24 Left bundle branch area pacing was also associated with a lower time to onset of both new-onset atrial fibrillation and ventricular arrhythmias, even in those patients with no history of ventricular arrhythmias who were naive to antiarrhythmic therapy.25 A meta-analysis of 4 randomized and 17 observational studies showed CSP was associated with a significant reduction in all-cause mortality and HF hospitalizations compared with BIVP for CRT.26
Future Directions
Despite the lack of large RCTs on these therapies, His bundle pacing and left bundle branch area pacing have been included in the most recent pacing guidelines for the avoidance and mitigation of HF as Class of Recommendation grades 2a and 2b, with similar indications to BIVP.22 Current Heart Rhythm Society, Asia Pacific Heart Rhythm Society, and Latin American Heart Rhythm Society guidelines recommend CSP as an alternative to traditional BIVP when effective CRT cannot be achieved (Class of Recommendation 2a).22 There are, however, multiple ongoing moderate to large RCTs that will fill gaps in clinical knowledge (Table I).
TABLE I.
Left ventricular ejection fraction ≤35% | Left ventricular ejection fraction 36%-49% | Left ventricular ejection fraction ≥50% |
---|---|---|
CSP-SYNC [NCT05155865] (CSP vs BIVP) (N = 60) End points: left ventricular ejection fraction, left ventricular volume, New York Heart Association classification, 6-minute walk test, quality of life |
His-PACE [NCT04672408] (His bundle pacing vs right ventricular pacing) (N = 50) End point: left ventricular ejection fraction |
|
HIS-alt_2 [NCT04409119] (CSP vs BIVP) (N = 125) End points: left ventricular end-systolic volume, QRS duration |
HIS-PrEF [NCT04529577] (His bundle pacing vs right ventricular pacing) (N = 40) End point: left ventricular ejection fraction |
|
HIS-CRT [NCT05265520] (His bundle pacing vs BIVP) (N = 120) End point: left ventricular ejection fraction |
LEAP [NCT04595487] (Left ventricular septal pacing vs right ventricular pacing) (N = 470) End points: death, HF hospitalizations, left ventricular ejection fraction decrease by 10% |
|
His-SYNC [NCT02700425] (His bundle pacing vs BIVP) (N = 41) End point: QRS duration |
LEFT HF [NCT05015660] (Left bundle branch area pacing vs right ventricular pacing) (N = 1,280) End points: cardiovascular death, HF events |
|
LeCaRT [NCT05365568] (Left bundle branch area pacing vs BIVP) (N = 170) End points: composite death, HF hospitalizations, worsening HF, implant failure, cardiac implantable electrical device re-intervention |
OptimPacing [NCT04624763] (Left bundle branch area pacing vs right ventricular pacing) (N = 683) End points: death, HF hospitalizations, pacemaker-induced cardiomyopathy |
|
LIT-HF [NCT05572957] (CSP vs guideline-directed medical therapy) (N = 50) End point: left ventricular ejection fraction |
PROTECT-HF [NCT05815745] (His bundle pacing vs right ventricular pacing) (N = 2,600) End points: cardiovascular death, HF events |
|
Left-Bundle CRT [NCT05434962] (Left bundle branch area pacing vs BIVP) (N = 176) End point: CRT response |
REINVENT-CRT [NCT05652218] (Left bundle branch area pacing vs BIVP) (N = 20) End point: myocardial perfusion imaging |
|
PhysioSync-HF [NCT05572736] (CSP vs BIVP) (N = 304) End points: death, HF hospitalizations, left ventricular ejection fraction |
||
CONSYST-CRT [NCT05187611] (CSP vs BIVP) (N = 130) End points: composite death, cardiac transplant, HF hospitalizations, and left ventricular ejection fraction |
LBB Pacing Versus Conventional Pacing in Atrioventricular Block [NCT05722379] (Left bundle branch area pacing vs right ventricular pacing) (N = 27) End point: global work efficiency |
|
HIPPOS [NCT05491655] (His bundle pacing vs backup right ventricular pacing) (N = 34) End point: left ventricular ejection fraction |
RHYSPAVB [NCT05214365] (His bundle pacing vs right ventricular pacing) (N = 200) End point: pacemaker-induced cardiomyopathy |
|
LBBAP-AFHF [NCT05549544] (Left bundle branch area pacing vs BIVP) (N = 60) End point: left ventricular ejection fraction |
Vanguard [NCT05015660] (Left bundle branch area pacing vs right ventricular pacing) (N = 100) End points: death, HF events, left ventricular end-systolic volume, changes in lead parameters, quality of life; and safety |
|
LBB Pacing in Patients with Cardiac Dysfunction and AV Block [NCT05553626] (Left bundle branch area pacing vs BIVP) (N = 160) End point: left ventricular ejection fraction |
||
Left vs Left [NCT05650658] (CSP vs BIVP) (N = 2,136) End points: death, HF hospitalizations, quality of life |
BIVP, biventricular pacing; CRT, cardiac resynchronization therapy; CSP, conduction system pacing; HF, heart failure.
Physiologic pacing for HF with a left ventricular ejection fraction of less than 50% remains a dynamic field with multiple ongoing RCTs that will determine the relative benefits and safety of different pacing modalities. There is also an acute need to develop sheaths, leads, devices, and algorithms to improve and optimize the success rate of CSP.
Abbreviations
- BIVP
biventricular pacing
- CRT
cardiac resynchronization therapy
- CSP
conduction system pacing
- HF
heart failure
- RCT
randomized clinical trial
Article Information
Open Access: © 2024 The Authors. Published by The Texas Heart Institute®. This is an Open Access article under the terms of the Creative Commons Attribution-NonCommercial License (CC BY-NC, https://creativecommons.org/licenses/by-nc/4.0/), which permits use and distribution in any medium, provided the original work is properly cited, and the use is noncommercial.
Author Contributions: Nathan Smith assisted in the conceptualization of the manuscript; he wrote the initial draft of this paper, revised it, and incorporated revisions into the writing of subsequent drafts. Patrick Lynch assisted in the conceptualization of the manuscript and contributed to revision of the initial and subsequent drafts. Mihail Chelu conceived of the manuscript and contributed to the revisions of the initial and subsequent drafts.
Conflict of Interest Disclosure: None.
Funding/Support: Dr Chelu received research support from the Patient-Centered Outcomes Research Institute, National Institutes of Health, Impulse Dynamics, and Abbott. He received speaker's fees from Impulse Dynamics.
Section Editor: Mohammad Saeed, MD.
Meeting Presentation: Presented at: The Ali Massumi Cardiac Arrhythmia Symposium; February 24, 2024; Houston, TX.
References
- 1.Auricchio A, Prinzen FW. Enhancing response in the cardiac resynchronization therapy patient: the 3B perspective-bench, bits, and bedside. JACC Clin Electrophysiol. 2017;3(11):1203–1219. doi: 10.1016/j.jacep.2017.08.005. doi: [DOI] [PubMed] [Google Scholar]
- 2.Cazeau S, Leclercq C, Lavergne T, et al. Multisite Stimulation in Cardiomyopathies (MUSTIC) Study Investigators. Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay. N Engl J Med. 2001;344(12):873–880. doi: 10.1056/NEJM200103223441202. doi: [DOI] [PubMed] [Google Scholar]
- 3.Auricchio A, Stellbrink C, Sack S, et al. Pacing Therapies in Congestive Heart Failure (PATH-CHF) Study Group. Long-term clinical effect of hemodynamically optimized cardiac resynchronization therapy in patients with heart failure and ventricular conduction delay. J Am Coll Cardiol. 2002;39(12):2026–2033. doi: 10.1016/s0735-1097(02)01895-8. doi: [DOI] [PubMed] [Google Scholar]
- 4.Abraham WT, Fisher WG, Smith AL, et al. MIRACLE Study Group. Multicenter InSync Randomized Clinical Evaluation. Cardiac resynchronization in chronic heart failure. N Engl J Med. 2002;346(24):1845–1853. doi: 10.1056/NEJMoa013168. doi: [DOI] [PubMed] [Google Scholar]
- 5.Higgins SL, Hummel JD, Niazi IK, et al. Cardiac resynchronization therapy for the treatment of heart failure in patients with intraventricular conduction delay and malignant ventricular tachyarrhythmias. J Am Coll Cardiol. 2003;42(8):1454–1459. doi: 10.1016/s0735-1097(03)01042-8. doi: [DOI] [PubMed] [Google Scholar]
- 6.Young JB, Abraham WT, Smith AL, et al. Multicenter InSync ICD Randomized Clinical Evaluation (MIRACLE ICD) Trial Investigators. Combined cardiac resynchronization and implantable cardioversion defibrillation in advanced chronic heart failure: the MIRACLE ICD Trial. JAMA. 2003;289(20):2685–2694. doi: 10.1001/jama.289.20.2685. doi: [DOI] [PubMed] [Google Scholar]
- 7.Sutton MGSJ, Plappert T, Hilpisch KE, Abraham WT, Hayes DL, Chinchoy E. Sustained reverse left ventricular structural remodeling with cardiac resynchronization at one year is a function of etiology: quantitative Doppler echocardiographic evidence from the Multicenter InSync Randomized Clinical Evaluation (MIRACLE) Circulation. 2006;113(2):266–272. doi: 10.1161/CIRCULATIONAHA.104.520817. doi: [DOI] [PubMed] [Google Scholar]
- 8.Cleland JGF, Daubert JC, Erdmann E, et al. Cardiac Resynchronization-Heart Failure (CARE-HF) Study Investigators. The effect of cardiac resynchronization on morbidity and mortality in heart failure. N Engl J Med. 2005;352(15):1539–1549. doi: 10.1056/NEJMoa050496. doi: [DOI] [PubMed] [Google Scholar]
- 9.Curtis AB, Worley SJ, Adamson PB, et al. Biventricular versus Right Ventricular Pacing in Heart Failure Patients with Atrioventricular Block (BLOCK HF) Trial Investigators. Biventricular pacing for atrioventricular block and systolic dysfunction. N Engl J Med. 2013;368(17):1585–1593. doi: 10.1056/NEJMoa1210356. doi: [DOI] [PubMed] [Google Scholar]
- 10.Curtis AB, Worley SJ, Chung ES, Li P, Christman SA, Sutton MSJ. Improvement in clinical outcomes with biventricular versus right ventricular pacing: the BLOCK HF Study. J Am Coll Cardiol. 2016;67(18):2148–2157. doi: 10.1016/j.jacc.2016.02.051. doi: [DOI] [PubMed] [Google Scholar]
- 11.Nagy KV, Merkely B, Rosero S, et al. Quality of life predicting long-term outcomes in cardiac resynchronization therapy patients. Europace. 2019;21(12):1865–1875. doi: 10.1093/europace/euz262. doi: [DOI] [PubMed] [Google Scholar]
- 12.Bristow MR, Saxon LA, Boehmer J, et al. Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) Investigators. Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med. 2004;350(21):2140–2150. doi: 10.1056/NEJMoa032423. doi: [DOI] [PubMed] [Google Scholar]
- 13.Tang ASL, Wells GA, Talajic M, et al. Resynchronization-Defibrillation for Ambulatory Heart Failure Trial Investigators. Cardiac-resynchronization therapy for mild-to-moderate heart failure. N Engl J Med. 2010;363(25):2385–2395. doi: 10.1056/NEJMoa1009540. doi: [DOI] [PubMed] [Google Scholar]
- 14.Køber L, Thune JJ, Nielsen JC, et al. DANISH Investigators. Defibrillator implantation in patients with nonischemic systolic heart failure. N Engl J Med. 2016;375(13):1221–1230. doi: 10.1056/NEJMoa1608029. doi: [DOI] [PubMed] [Google Scholar]
- 15.Moss AJ, Hall WJ, Cannom DS, et al. MADIT-CRT Trial Investigators. Cardiac-resynchronization therapy for the prevention of heart-failure events. N Engl J Med. 2009;361(14):1329–1338. doi: 10.1056/NEJMoa0906431. doi: [DOI] [PubMed] [Google Scholar]
- 16.Goldenberg I, Kutyifa V, Klein HU, et al. Survival with cardiac-resynchronization therapy in mild heart failure. N Engl J Med. 2014;370(18):1694–1701. doi: 10.1056/NEJMoa1401426. doi: [DOI] [PubMed] [Google Scholar]
- 17.Gill EA, Poole JE. Will the real left bundle branch block please stand up? J Am Coll Cardiol. 2015;66(6):642–644. doi: 10.1016/j.jacc.2015.06.1299. doi: [DOI] [PubMed] [Google Scholar]
- 18.Poole JE, Singh JP, Birgersdotter-Green U. QRS duration or QRS morphology: what really matters in cardiac resynchronization therapy? J Am Coll Cardiol. 2016;67(9):1104–1117. doi: 10.1016/j.jacc.2015.12.039. doi: [DOI] [PubMed] [Google Scholar]
- 19.Deshmukh P, Casavant DA, Romanyshyn M, Anderson K. Permanent, direct His-bundle pacing: a novel approach to cardiac pacing in patients with normal His-Purkinje activation. Circulation. 2000;101(8):869–877. doi: 10.1161/01.cir.101.8.869. doi: [DOI] [PubMed] [Google Scholar]
- 20.Huang W, Su L, Wu S, et al. A novel pacing strategy with low and stable output: pacing the left bundle branch immediately beyond the conduction block. Can J Cardiol. 2017;33(12):1736.e1–1736.e3. doi: 10.1016/j.cjca.2017.09.013. doi: [DOI] [PubMed] [Google Scholar]
- 21.Vijayaraman P, Sharma PS, Cano Ó, et al. Comparison of left bundle branch area pacing and biventricular pacing in candidates for resynchronization therapy. J Am Coll Cardiol. 2023;82(3):228–241. doi: 10.1016/j.jacc.2023.05.006. doi: [DOI] [PubMed] [Google Scholar]
- 22.Chung MK, Patton KK, Lau CP, et al. 2023 HRS/APHRS/LAHRS guideline on cardiac physiologic pacing for the avoidance and mitigation of heart failure. Heart Rhythm. 2023;20(9):e17–e91. doi: 10.1016/j.hrthm.2023.03.1538. doi: [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Diaz JC, Sauer WH, Duque M, et al. Left bundle branch area pacing versus biventricular pacing as initial strategy for cardiac resynchronization. JACC Clin Electrophysiol. 2023;9(8 Pt 2):1568–1581. doi: 10.1016/j.jacep.2023.04.015. doi: [DOI] [PubMed] [Google Scholar]
- 24.Wang Y, Zhu H, Hou X, et al. LBBP-RESYNC Investigators. Randomized trial of left bundle branch vs biventricular pacing for cardiac resynchronization therapy. J Am Coll Cardiol. 2022;80(13):1205–1216. doi: 10.1016/j.jacc.2022.07.019. doi: [DOI] [PubMed] [Google Scholar]
- 25.Herweg B, Sharma PS, Cano Ó, et al. Arrhythmic risk in biventricular pacing compared with left bundle branch area pacing: results from the I-CLAS study. Circulation. 2024;149(5):379–390. doi: 10.1161/CIRCULATIONAHA.123.067465. doi: [DOI] [PubMed] [Google Scholar]
- 26.Kim JA, Kim SE, Ellenbogen KA, Vijayaraman P, Chelu MG. Clinical outcomes of conduction system pacing versus biventricular pacing for cardiac resynchronization therapy: a systematic review and meta-analysis. J Cardiovasc Electrophysiol. 2023;34(8):1718–1729. doi: 10.1111/jce.15976. doi: [DOI] [PubMed] [Google Scholar]